{{#Wiki_filter:.
{{#Wiki_filter:}}
Attachment to 2CAN079403 l
Inservice Inspection Summary Report i
Arkansas Nuclear One, Unit 2 l'
Outage Number: 2R10 Outage Completion Date: 4/24/94 f.
Owner                ,
Arkansas Power & Light Company P. O. Box 551 TCBY Building _
Little Rock, Arkansas 72203 Operator Entergy Operations, Inc.
Subsidiary of Entergy Corporation Generating Plant Arkansas Nuclear One Route 3, Box 137G Russellville, AR 72801 l
l Commercial Operating Date: March 26,1980 Submittal Date: July 8,1994 l
,  ;!R72ggggggggg;gs, g
PDR 1
 
Attachm:nt to 2CAN079403 FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS AND 2R10 OUTAGE
 
==SUMMARY==
REPORT l
i I
1 1
 
i Attachment to                                                                                      i 2CAN079403                                                                                        l l
Abstract of Examinations and Tests A listing of all ISI examinations / inspections performed since the completion of 2R9 and the breaker closure of the 2R10 refueling outage are located on the suppiemental pages to the NIS-1 form. This listing includes examinations / inspections performed both non-outage (pre-2R10) and during the 2R10 refueling outage. This was the first refueling outage of the l  current inspection period. The current status of the inspection plan is listed below.
Inspection Period                              Inspection Interval 2                                              2 l
Abstract of Results of Examination and Tests l
l  Attached are tables entitled the "ANO-2 ISI Component Examination / Inspection j  Summary. " These tables provide a comprehensive summary of the examinations or inspections performed for each componenti , including all volumetric examination techniques utilized (e.g., refracted-longitudinal wave propagation for dissimilar metal welds), and group the results into three categories. An explanation of the results categories is listed below:
l NOREC - no recordable indications GEOAI - volumetric indications with a geometric origin OTHER - all recordable non-geometric indications / findings requiring evaluation The examinations / inspections performed revealing "OTIIER" indications / findings requiring evaluations and/or actions are listed below.
IWB                      IWC              IWD                      IWF Vol        Surf        Vol        Surf        Vis    Vis - Cl1    Vis- Cl2      Vis- Cl3 02-001      24-047      03-035      03-034      None        21-072      18-019        71-020 17-002    62-009W                  22-071      19-034        71-022  l 63-015                              23-059      91-103        72-141  j 24-078      91-111        73-111 24-085 26-054 28-037 29-069 41-045 l
1 The results of the eddy current testing of steam generator tubing are reported in accordance with ANO-2 Technical Specifications 4.4.5.5.b and 6.9.1.5.b.
l l
l
 
  -J,./~. 4      .a4.. J    2. J.L rp_ ,me-hA.- .is u. m: L  _wA.  .e4 J,4c. , d 9a -.w.4 - - . -.;;. mi4-      G. 4 s ,,,,2, l          2 Attachment to
!            2CAN079403 Abstract of Corrective Measures Corrective actions taken in response to "OTHER" indications / findings are described in the remarks column of the tables for each applicable component.
9 4
i I
i t
I l
l i
 
Page 1 of 11
;                  FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules i
l                Arkansas Power & Light Company /Entergy Operations, Inc.
l  1. Owner    P. O. Box 551. TCBY Building, Little Rock. AR 72203 (Name and Address of Owner) l  2. Plant Arkansas Nuclear One, Rt 3 Box 137G, Ruesellville, AR 72801 i
(Name and Address of Plant) l
!  3. Plant Unit    2    4. Owner Certificate of Authorization (if required)          N/A l
!  5. Commercial Service Date          03/26/80    6. National Board Number for Unit      22009
: 7. Components Inspected      ASME Code Class 1 (IWB), Class 2 (IWC), and Class 3 (LWD)
Components and Their Supports (IWF)
Manufacturer j      Component or              Manufacturer            or Installer        State or    National l      Appurtenance              or Installer            Serial No.        Province No. Board No.
(Manufacturer)
Reactor Vessel                Combustion Engr              206-1            ARK-2204      22009 (Manufacturer)
Pressurizer                  Combustion Engr            2T-001            ARK-2201      21497 Steam                          (Manufacturer) l  Generator 2E24A              Combustion Engr            2E24A            ARK-2203      21083 l
Steam                          (Manufacturer) l  Generator 2E24B              Combustion Engr            2E248            ARK-2202      21084 Reactor Coolant                (Manufacturer)
Pump 2P32A                    Byron Jackson                N/A                N/A        N/A Reactor Coolant                (Manufacturer)
Pump 2P32C                    Byron Jackson                N/A                N/A        N/A Reactor Coolant                (Manufacturer)
Pump 2P32D                    Byron Jackson                N/A                N/A        N/A (Installer)
HPSI Pump 2P89A                    Bechtel                  N/A                N/A        N/A (installer)
Class 1 Piping                    Bechtel                  N/A                N/A        N/A (Installer)
Class 2 Piping                    Bechtel                  N/A                N/A        N/A (Installer)
Class 3 Piping                    Bechtel                  N/A                N/A        N/A Class 1                          (Installer)
Component Supports                Bechtel                N/A                N/A        N/A Class 2                          (Installer)
Component Supports                Bechtel                N/A                N/A        N/A Class 3                          (Installer)
Component Supports                Bechtel                N/A                N/A        N/A N/A N/A AP&UEntergy by          b
                    / D PL6 mix
                                .27 Date gd Factory Mutual by 9.O [M Date 6/,2 3/9y f J. O. Elliott, ANil EPG94013
 
Page 2 of 11 i FORM NIS-1 (Back)
: 8.      Examination Dates            10/20/92      to        4/24/94
: 9.      Inspection Period identification:      1st Refueling Outage of 2nd Inspection Period l
: 10. Inspection Interval Identification:        2nd Inspection interval
: 11. Applicable Edition of Section XI              1986        Addenda          N/A
: 12. Date/ Revision of Inspection Plan: Revision 4
: 13. Abstract of Examinations and Tests. Include a list of examinations and tests and a                      l statement concerning status of work required for the inspection Plan.
See attached "2R10 Outage Summary Report Overview".
: 14. Abstract of Results of Examinations and Tests.
See attached "2R10 Outage Summary Report Overview"
: 15. Abstract of Corrective Measures.
See attached "2R10 Outage Summary Report Overview".
We certify that a) the statements made in this report are correct, b) the examinations and tests meet the inspection Plan as required by ASME Code, Section XI, and c) corrective measures taken conform to the rules of the ASME Code, Section XI.
Certificate of Authorization No. (if applicable)            N/A        Expiration Date        N/A Date          21      19        Signed    AP&tJEntergy Operations. Inc. By          M
              '                                          Owner                        # D. B. Lomi(x CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Arkansas and employed by Arkwricht Mutual Insurance CA of Norwood. Mass have inspected the components described in this Owners Report during the period lo/.2 c/9.1 to 'l/.1 WW and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the inspection plan and as required by the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations, tests, and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
Factory Mutual Engineering Association 9.O      dM)                    Commissions                NB-9947. ARK 1133 "N" "I" "A" National Board, State, Province, and Endorsements 7      Inspectors Signature J. O. Elliott Dateb s A 3 19 W V
EPG94013
 
l, Pagg 3 of 11 SUPPLEMFNT TO FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS FOR ASME Code Class 1 (lWB), Class 2 (lWC), and Class 3 (LWD) Components and Their Supports (lWF)
Arkansas Power & Light Company /Entergy Operations, Inc.
: 1. Owner      P. O, Box 551 TCBY Building, Little Rock, AR 72203 (Name and Address of Owner)                                                              ]
: 2. Plant Arkansas Nuclear One, Rt 3 B0x 137G, Russellville, AR 72801                                                                        I (Name and Address of Plant)                                                            )
l
: 3. Plant Unit          2      4,      owner and Certificate of Authorization (if required) '                              N/A 5.'  Commercial Service Date .                03/26/80      6.            National Boatd Number for Unit                    22009 l
l ASME      ASME                                                                Exam                                                              '
Cateoory item No        comoonent or System              Exam No.            Method Descriotion '
B-A        B 1.40    ' Reactor Vessel Closure Head      02-001
* UT.MT    Flange To Peel Segment Torus                            ,
l B-D        B 3.110      Pressurizer Vessel              05-009
* UT      ' 12" Surge Nozzle To Bottom Head Weld B-D        B 3.110 - Pressurizer Vessel                  05-012
* UT        6" Safety Nozzle To Top Head Wold @ 60* ..
B-D        B 3.110      Pressunzer Vessel                05-013
* UT-      6" Safety Nozzle lo Top Head Weld @ 270*
B-D        B 3.120      Pressurizer Vessel              05-120              UT        12" Surge ' Nozzle Inner Radius'                        !
B-D        B 3.120      Pressurizer Vessel              05 123*              UT        6" Safety Nozzle Inner Radius @ 60*                    '
B-D        B 3.120      Pressurizer Vessel              05-124 *.            UT        6" Safety Nozzle inner Radius @ 270*
B-F        B 5.130      Chemical & Volume Control        40-026              UT,MT    Piping Dissimilar Metal Butt Weld B-F        B 5.130      Reactor Coolant (Surge Line)    16-001
* UT,PT    Piping Dissimilar Metal Butt Weld .
BF        B 5.130      Safety injection                22-001
* UT,PT ~ Piping Dissimilar Metal Butt Weld B-F        B 5.40      Pressurtzer Vessel              42-002
* UT,PT    Piping Dissimilar Metal Butt Weld B-F        B 5.40      Pressurizer Vessel              42-003
* UT PT    Piping Dissimilar Metal Butt Weld B-F        B 5.40      Reactor Coolant (Surge Line)    16-014*              UT,PT    Piping Dissimilar Metal Butt Weld B-G-2      B 7.10      Reactor Vessel Closure Head      02-B-085            VT 1    - Instrument Nozzle Flange Botting                    -
B-G-2      B 7.10      Reactor Vessel Closure Head      02-B-086            VT-1      Instrument Nozzle Flange Bolting                        '
B-G-2      B T.10      Reactor Vessel Closure Head      02-B-087            VT-1      Instrument Nozzle Flange Bolting B-G-2      B 7.50      Pressunzer Vessel                42-011              V' 1      Flange Bolting B-G 2      B 7.50      Pressunzer Vessel                42-012              W1        Flange Bolting B-J        B45          Shutdown Cooling                25-017 =            UT        Piping Circumferential Butt Weld B-J        B 9.11      Reactor Coolant                  28-008              UT,PT    Piping Circumferential Butt Weld BJ        B 9.11      Reactor Coolant                  28-009              UT.PT    Paping Circumferential Butt Weld B-J        B 9.11      Reactor Coolant (Surge Line)    16-003
* UT,PT    Pipiag Circumferential Butt Weld B-J        B 9.11      Reactor Coolant (Surge Line)    16-004              UT PT    Piping Circumferential Butt Weld -
B-J        B 911        Reactor Coolant (Surge Line)    16-011              UT,PT    Piping Circumferential Butt We!d B-J        B 9.11      Reactor Coolant (Surge Line)    16-012              UT,PT    Piping Circumferential Butt Weld B-J        B 9.11      Safety injection ~              22-012              . UT,PT    Piping Circumferential Butt Weld B.J        B 911        Safety injection                22 013              UT,PT    Peing Circum 4rential Butt Weld B-J        B 9.11      Safety injection                22-016'              UT,PT    Piping Circumferential Butt Weld B-J      . B 9.11      Safety injection                22-018              UT,PT    Piping Circumferential Butt Weld BJ        B 911        Safety injection                22-019
* UT,PT-    Piping Circumferential Butt Weld B-J        B 9.11      Safety injection              . 22-024              UT,PT    Piping Circumferential Butt Weld
* The examination volume / area of this component was not fully examined 100% due to an examination limitation, The percentage of coverage achieved will be calculated and Relief Requests will be submitted as necessary.
AP&L/Entergy by                            J ate              Factory Mutual by 9. o,2/A D                            Date /,/43/9s
                                    / D. B. Loinax/                                                    (/ J, O. Elliott, ANil EPG94013
 
l l
l                                                                                                                Page 4 of 11  ,
SUPPLEMENT TO FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS FOR ASME Code Class 1 (lWB), Class 2 (IWC), and Class 3 (LWD) Components and Their Supports (lWF)
Arkansas Power & Light Company /Entergy Operations, Inc.
: 1. Owner        P. O. B0x 551 TCBY Building, Little Rock, AR 72203 l
(Name and Address of Owner)
: 2. Plant Arkansas Nuclear One, Rt 3 Box 137G, RuSSellville, AR 72801                                                      l (Name and Address of Plant)
: 3. Plant Unit        2      4. Owner and Certificate of Authorization (if required)                    N/A S. Commercial Service Date              03/26/80    6.      National Board Number for Unit                22009 l
l t
l ASME      ASME                                                    Exam
  . C.atsggar item No      comoonent or System          Exam No.      Method Descriotinn                                      j B4        8 9.11      Rafety injectron              22-025        UT,PT  Piping Circumferential Butt Weld B-J        B 9.11      Safety injection              22-026        UT,PT  Piping Circumferential Butt Weld B-J        B 9.11      Safety injection              24-031
* UT.PT  Piping Circumferential Butt Weld B-J        B 9.11      Safety injection              24-032        UT,PT  Piping Circumferential Butt Weld                  l i
B4        B 9.11      Safety injection              24-033        UT.PT  Piping Circumferential Butt Weld                  l B-J        B 9.11      Safety injection              24 047        UT,PT  Piping Circumferent,al Butt Weld l
l  B-J        B 9 21      Chemical & Volume Control    29-056        UT,PT  Piping Circumferential Butt Weld B-J        B 9.21      Reactor Coolant              28-041        PT      Piping Circumferential Butt Weld
!  B-J        B 9 21      Reactor Coolant              28-042        PT      Piping Circumferential Butt Weld l  B4        B 9.21      Reactor Coolant              28-043        PT      Piping Circumferential Butt Weld B-J        B 9 21      Reactor Coolant              28-044        PT      Piping Circumferential Butt Weld B-J        B 9 21      Reactor Coolant              28-045        PT      Piping Circumferential Butt Weld                  !
B-J        B 921      Reactor Coolant              28-046        PT      Piping Circumferential Butt Weld                  l i
B-J        B 9.21      Reactor Coolant              28-047        PT      Piping Circumferential Butt Weld                i BJ        B 9.21      Reactor Coolant              28-048        PT      Piping Circumferential Butt Weld l
B4        B 9 21      Reactor Coolant              28-049        PT      Piping Circumfeiential Butt Weld B-J        B 9.21      Safety injection              22-041        PT      Piping Circumferential Butt Weld B-J        B 9.21      Safety injection              24-050        PT      Piping Circumferential Butt Weld B-J        B 9.40      Chemical & Volume Control    29-054        PT      Piping Socket Weld B4        B 9 40      Chemical & Volume Control    29-055        PT      Piping Socket Weld B K-1      B 10.10    Safety injection              22-071W        PT      Integrally Welded Attachment 2CCA-22-H7 B-K 1      B 10.10    Safety injection              24-081W        PT      Integrally Welded Attachment 2CCA-23-H22 B-Q        B 16 20    Steam Generator 2E24A        N/A            ET      Tubing B-Q        B 16.20    Steam Generator 2E248        N/A            ET      Tubing C-B        C 2.21      Steam Generator 2E24A        03-034
* UT,MT  Main Stearn Nozzle To Top Head Dome C-B        C 2.21      Steam Generator 2E24A        03-035        UT      Feedwater Nozzle To Upper Shell C-B        C 2.21      Steam Generator 2E24B        04-034        MT      Main Steam Nozzle To Top Head Dome C-B        C 2 22      Steam Generator 2E24A        03-042        UT      Main Steam Nozzle inner Radius Section C-C        C 3.20      Main Feedwater                62-009W        MT      Integrally Welded Attachment 2DBB 1-HS C-C        C 3.20      Main Steam                    18-019W        MT      Integrally Welded Attachment 2 EBB 1 A-H1 C-C        C 3.20      Main Steam                    65-036W        MT      Integrally Welded Attachment 2 EBB-2-H2 C-C        C 3 20      Main Steam                    65-038W        MT      IntegrallyWelded Attachment 2 EBB 2-H5 C-C        C 3 20      Safety injection              66 017W
* PT      Integrally Welded Attachment 2CCB-5-H1
* The examination volume / area of this component was not fully examined 100% due to an examination limitation.
The percentage of coverage achieved will be calculated and Relief Requests will be submitted as necessary.
AP&UEntergy by                -
Date &          Factory Mutual by 9.o. [M Date 4Z2 3/gy
                        / D. B. L'Omix                                            (7 J. O. Elliott, ANil EPG94013
 
Page 5 of 11-SUPPLEMENT TO FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS FOR ASME Code Class 1 (lWB), Class 2 (IWC), and Class 3 (LWD) Components and Their Supports (IWF)~
i Arkansas Power & Light Company /Entergy Operations, Inc.
: 1. Owner ' P. O, Box 551, TCBY Building, Little Rock, AR 72203                                                                                          ,
(Name and Address of Owner) l i                2. Plant Arkansas Nuclear One, Rt 3 Box 137G, RuSSellville, AR 72801
                                                                                                                                                                ~
(Name and Address of Plant)                                                            i
: 3. _ Plant Unit ~          2        4. Owner and Certificate of Authorization (if required)                                  -N/A              _;
: 5. Commercial Service Date                              03/26/80'      6. National Board Number for Unit                    22009
* ASME        ASME                                  .
Exam Cateoory item No              comoonent or System                      Exam No.        Mathed Descriotion                                                .;
C-E-1        C 2.5            Shutdown Cooling                          59-049W.        PT        Integrafty Weided Attachment 2GCB-16-H2 -
C-F-1        -                Safety injectm                            52-013          UT,PT - Piping Circumferential Butt Wold                            >
C-F              -
Safety injection                          52-014          UT PT ' ' Piping Circumferential Butt Weld C-F-1        -                Safety injection                          52-032          UT,PT ' Piping Circumferential Butt Weld
* C-F-1        -
                                            . Shutdown Cooling'                        56-003 ~~      UT,PT      Piping Circumferential Butt Weld                          ;
C-F-1              -
Safety injection '                        52 013AB        UT,PT      Piping Longitudinal Wold                                  1 C-F-1        -                Safety injection                          52-015AB        UT,PT - Piping Longitudinal Weld
              - C-F-1.      -                Safety injection                      031 AB        UT.PT      Piping LongitudinalWeld C-F      -                Shutdown Coolir g                        56-004AB        UT,PT      Pipmg Longitudinal Weld -
i
!'              C-F 2        C 5.51          Main Feedwater                            17-001          UT        Piping Circumferential Butt Weld C-F C 5.51                Main Feedwater                            17-002          UT        Piping Circumferential Butt Weld C-F-2        C 5.51          Main Feedwater                            17-003          UT        Piping Circumferential Butt Weld C.F.2        C 5.51          Main Feedwater                            19-001          UT        Piping Circumferential Butt Weld .
C-F-2        C 5.51          Main Feedwater                            19-002          UT        Piping Circumferential Butt Weld l
C-F-2        C 5.51          Main Feedwater                            19-003        -UT        Piping Circumferential Butt Weld C-F-2      C 551            Main Feedwater                            62 002          UT,MT      Piping Circumferential Butt Weld C-F-2        C 5 51          Main Feedwater                            64-002          UT,MT      Piping Circumferential Butt Weld .                        ,
C-F-2        C 5 51          Main Feedwater                            64-003          UT,MT      Piping Circumferential Butt Weld                          -
C-F-2        C 5.51          Main Feedwater                            64-004          UT,MT      Piping Circumferential Butt Weld .
C-F 2        C 5.51          Main Steam                                18-001 _        UT MT Piping Circumferential Butt Weld
'                C-F-2        C 5.51          Main Steam                                18-002          UT,MT . Piping Circumferential Butt Weld C-F-2        C 5.51          Main Steam                                18-003          UT,MT      Piping Circumferential Butt Weld C-F-2        C 5.51          Main Steam                              18-005          UT.MT      Piping Circumferential Butt Weld .
C-F-2        C 5.51          Main Steam                              63-006
* UT,MT      Piping Circumferential Butt Weld C-F-2    ' C 5 51            Main Steam                              63-013          UT        Piping Circumferential Butt Weld C-F 2        C 5.51          Main Steam                              63-014          UT        Piping Circumferential Butt Weld                          !
C-F-2        C 5.51          Main Steam                              63-015          UT        Piping Circumferential Butt Weld C-F-2        C 5.51          Main Steam                              63-016          UT        Piping Circumferential Butt Weld C-F 2        C 5.51          Main Steam                              63-017*        UT          Piping Circumferential Butt Weld
'                C-F-2        C 551            Main Steam -                            6S 019
* UT          Piping Circumferential Butt Weld C-F 2        C 5.51          Main Steam -                            65-021 * ~      UT,MT      Piping Circumferential Butt Weld C-F-2        C 5.52        - Main Steam                              63-015AB        UT-        Piping Longitudinal Weld
              - C.F.2        C 581            Main Steam                            ' 65-014          MT          Piping Branch Connection W,ld C-F 2        n/a              Main Steam                              63-017A
* UT          Piping Circumferential Butt Weld
* The examination volume / area of this component was not fully examined 100% due to an examination limitation.
The percentage of coverage achieved will be calculated and Relief Requests will be submitted as necessary.
AP&L/Entergy by                                            Date                Factory Mutual by 9_, /3, [2d Date G,u/9 y
: l.                                            ' D. BE Lom6x                                                          f J. O, Elliott, ANil l
{                EPG94013 l
r    . .,                . - .                    .                    -
                                                                                  .      ,a,                            , _ ,                                        ,  ,-
 
Pagg 6 of 11 l SUPPLEMENT TO FORM NIS 1 OWNER'S REPORT FOR INSERVICE INSPECTIONS                                            l FOR ASME Code Class 1 (IWB), Class 2 (IWC), and Class 3 (IWO) Components and Their Supports (lWF) 4 I
Arkansas Power & Light C0mpany/Entergy Operations, Inc.
: 1. Owner        P. O. Box 551, TCBY Building, Little Rock, AR 72203 (Name and Address of Owner)
: 2. Plant Arkansas Nuclear One, Rt 3 B0x 137G, Russellville, AR 72801 (Name and Address Of Plant)
: 3. Plant Unit        2      4. Owner and Certificate of Authorization (if required)                N/A
: 5. Commercial Service Date              03/26/80      6. National Board Number for Unit              22009 l
l ASME      ASME                                                  Exam Cateoorv Item No      comoonent or System          Exam No,    Method Descriotion                                    '
C-F 2    rua        Main Steam                    63-017C
* UT      Piping Circumferential Butt Weld C-F-2    n/a        Main Steam                    65-019A
* UT      Piping Circumferential Butt Weld C.F.2    n/a        Main Steam                    65-019C    UT      Piping Circumferential Butt Weld D-B      D 2.20      Emergency Feedwater          85-210W    VT 3    Integrally Weided Attachment 2DBC-2-H10 D-B      D 2.20      Emergency Feedwater          85-211W    VT-3    IntegrallyWelded Attachment 2DBC-2-H11 D-B      D 2.20      Emergency Feedwater          85-212W    VT-3    Integrally Welded Attachment 2DBC-2-H12 D-B      D 2.20      Emergency Feedwater          85-215W    VT 3    integrally Welded Attachment 2DBC-2-H15 D-B      D 2.20      Emergency Feedwater          85-217W    VT-3    Integrally Welded Attachment 2DBC-2-H17      i DB        D 2.20      cmergency Feedwater          85-218W    VT 3    Integrally Weided Attachment 2DBC-2-H18 D-B      D 2.20      Emergency Feedwater          85-221W    VT-3    Integrally Welded Attachment 2DBC-2-H21 D-B      D 2.20      Emergency Feedwater          94-036W    VT-3    Integrally Weided Attachment 2HCC-282-H36 D-B      D 2 20      Service Water                71-022W    VT-3    IntegrallyWelded Attachment 2HCB 34-H18 DB        D 2.20      Service Water                72-046W    VT-3    Integrally Weided Attachment 2HCB-50-H6 D-B      D 2 20      Service Water                72-100W    VT 3    Integrally Welded Attachment 2HBC-50-H10 D-B      D 2.20      Service Water                72102W      VT-3    Integrally Welded Attachment 2HBC-83-H1 D-B      D 2.20      Service Water                72108W      VT 3    Integrally Weided Attachment 2HBC-83-H3 D-B      D 2.20      Service Water                72-109W    VT-3    Integrally Weided Attachment 2HBC-83-H6 D-B      D 2.20      Service Water                72-110W    VT 3    Integrally Welded Attachment 2HBC-83-H8 D-B      D 2 20      Service Water                72-111W    VT-3    Integrally Welded Attachment 2HBC-83-H7 D-B      D 2.20      Service Water                72112W      VT 3    Integrally Weided Attachment 2HBC-83-H5 D-B      D 2 20      Service Water                72-139W    VT 3    IntegrallyWelded Attachment 2HBC-103 H16 D-B      D 2.20      Service Water                72141W      VT-3    Integrally Welded Attachment 2HBC-103-H19 D-B      D 2.20      Service Water                73-038W    VT-3    Integrally Welded Attachment 2HBC-43-H3 D-B      D 2.20      Service Water                73-048W    VT-3    Integrally Welded Attachment 2HBC-76-H9 D-B      D 2.20      Service Water                73-056W    VT-3    Integralty Welded Attachment 2HBC-76-H13 D-B      D 2.20      Service Water                73-103W    VT 3    Integrally Welded Attachment 2HBC-76-H11 D-B      D 2.20      Service Water                73-110W    VT-3    Integrally Welded Attachment 2HBC-51-H6 D-B      D 2.20      Service Water                73-111W    VT-3    Integrally Weided Attachment 2HBC-76-H14      i l
D-B      D 2 30      Service W'ater                72136W      VT-3    Integrally Welded Attachment 2HBC-103 H18    )
D-B      D 2.40      Service Water                72115W      VT-3    Integrally Welded Attachment 2HBC-103-H29 D-B      D 2.40      Service Water                72-132W    VT-3    Integrally Welded Attachment 2HBC-103-H5 F-A      F 1.10A    Chemical & Volume Control    29-069      VT-3    One-Way Restraint 2CCA-16-H13 F.A      F 1.10A    Reactor Coolant              28-033      VT-3    One-Way Restraint 2CCA-15-H14 F-A      F 1.10A    Safety injection              22-054      VT-3    One-Way Restraint 2CCA-22-H2O F-A      F 1.10A    Safety injection              22-070      VT 3    One-Way Restraint 2CCA-22-H8 F-A        F 1.10A    Safety injection              22 071      VT-3    One-Way Restraint 2CCA-22-H7
* The examination volume / area of this component was not fully examined 100% due to an examination limitation.
The percentage of coverage achieved wl!! be calculated and Relief Requests will be submitted as necessary.
AP&LJEntergy by                        4 Date d'2 /M Factory Mutual by 4,d. 2_//M- Date (./13/9y
                      'D. B. L0 max  f        i f J. O. Elliott, ANil EPG94013
 
i Paga 7 cf 11 SUPPLEMENT TO FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS                                                                    ;
FOR                                                                            I ASME Code Class 1 (lWB), Class 2 (IWC), and Class 3 (LWD) Components and Their Supports (IWF) j                                              Arkansas Power & Light Company /Entergy Operations, Inc.
: 1. Owner        P. O. B0x 551. TCBY Building, Little ROCK, AR 72203 (Name and Address of Owner)
: 2. Plant Arkansas Nuclear One, Rt 3 B0x 137G, Russellville, AR 72801 l                                                                                (Name and Address of Plant) -
: 3. Plant Unit            2      4. Owner and Certificate of Authorization (if required)                          N/A
: 5. Commercial Service Date                03/26/80      6. National Board Number for Unit                      22009 ASME      ASME                                                        Enm Category item No          comoonent or System            Exam No.      Method _ Description '
F-A        F1.10A        Safety injection            086        VT = One-Way Restraint 2CCA 23-H24 '
F-A        F 1.10B        Reactor Coolant                28-034        VT-3          Multi-Directional Restraint 2CCA-15-H13
;                        FA        F 1.10C        Reactor Coolant                28-035-'      VT-3          Variable Spring 2CCA-15-H1
: l.                        F-A        F 1.10C        Safety injection              22-053        VT 3          Variable Spring 2CCA-22-H1 F1.10C - Safety injection-F-A                                                      22-063        VT-3          Variable Spring 2CCA-22-H4 F-A      . F 1.10C      Safety injection            . 24-078        VT-3          Variable Spnng 2CCA-23-H4 FA        F 1.10C ' Safetyinjection                    24-083        VT-3          Variable Spnng 2CCA-23-H7 '                            '
F-A        F 1.10C        Safety injection              .24-085        VT-3          Variable Spring 2CCA-23-H8 F-A        F 1.10F        Chemica! & Volume Control      29-028        VT-3          Snubbor 2CCA-16-H1 F-A        F1.10F        Chemical & Volume Control      29-036        VT-3          Snubber 2CCA-16-H3 F-A        F 1.10F        Chemical & Volume Control      29-038        VT-3          Snubber 2CCA 16 H4 F.A        F 1.10F        Chemica: & Volume Control      29-062        VT 3          Snubber 2CCA-16-H21
* FA        F 1.10F        Chemical & Volume Control    . 29-064        VT-3        = Snubber 2CCA 16-H16 F-A        F 1.10F ' Chem: cal & Volume Control          29-068        VT-3          Snubber 2CCA-16-H12 l                        F-A        F 1.10F        Chemmal & Volume Control      41-045        VT 3          Snubber 2CCA-26-H2 j                        F-A        F 1.10F      Reactor Coolant                26-024        VT 3          Snubber 2CCA-14-H2                                      ;
F-A        F1.10F        Reactor Coolant                26-028        VT 3          Snubber 2CCA-15-H9 F-A        F 1.10F      Reactor Coolant -              26-030        VT-3          Snubber 2CCA-15-H27 F-A        F 1.10F      Reactor Coolant                26-031        VT 3        : Snubber 2CCA-15-H26 F-A        F 1.10F      Reactor Coolant                26-053        VT-3          Snubber 2CCA 14-H5
* F-A        F 1.10F      Reactor Coolant                26-054        VT ' Snubber 2CCA 15-H45 -                                          l l                        F-A        F 1.10F      Reactor Coolant                26-055        VT-3            Snubber 2CCA 15-H44 -                                  !
:                        F-A        F 1.10F      Reactor Cootant                26-060        VT          Snubber 2CCA 15-H41                                    1
{                        F-A        F1.10F        Reactor Coolant                26-062        VT-3            Snubber 2CCA 15-H39 i-                        F-A        F 1.10F      Reactor Coolant                27-030        VT-3            Snubber 2CCA 13-H4 F-A        F 1.10F    ' Reactor Coolant                27-034        VT-3            Snubber 2CCA-15-H24 F-A        F1.10F        Reactor Coolant                27-067        VT-3            Snubber 2CCA-15-H60 F-A        F 1.10F      Reactor Coolant                27 074        VT 3          Snubber 2CCA 15-H56 '
F-A        F 1.10F      Reactor Coolant                27-076        VT-3          Snubber 2CCA 15-H53 F-A        F1.10F        Reactor Coolant -              27-078        VT-3          Snubber 2CCA-15-H50 -
F-A        F 1.10F      Reactor Coolant                27-081        VT-3 ' . Snubber 2CCA-15-H48 F-A        F 1.10F - Reactor Coolant                    28-036      ~ VT 3          Snubber 2CCA-15-H29 :
FA          F 1,10F      Reactor Coolant                28-037        VT-3          Snubber 2CCA-15-H30                                    !
F-A        F1.10F        Reactor Coolant                28-054-      VT-3          Snubber 2CCA 15-H31                                    1 FA          F1.10F        Reactor Coolant                28-056        VT 3        . Snubber 2CCA 15-H34                                    j F-A        F 1.10F      Reactor Coolant                28-058        VT 3        - Snubber 2CCA 15-H36                                    l F-A        F 1.10F      Reactor Coolant                35-019        VT        Snubber 2CCA-32-H2 l
* The examination volume / area of this component was not fully examined 10C% due to an examination limitation The percentage of coverage achieved will be calculated and Relief Requests will be submitted as necessary.
i AP&L/Entergy by M Date p          Factory Mutual by 02./AIG-                            Date /,/,23/vy l                                                  ' D. B. Lorhax                                                      J. O. Elliott, ANil EPG94013
 
Pags 8 of 11 SUPPLEMENT TO FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS FOR ASME Code Class 1 (IWB), Class 2 (IWC), and Class 3 (LWD) Components and Their Supports (IWF)
Arkansas Power & Light Company /Entergy Operations, Inc.
: 1. Owner      P. O. B0x 551, TCBY Building, Little Rock, AR 72203 (Name and Address of Owner)
: 2. Plant Arkansas Nuclear One, Rt 3 B0x 137G, RusSeliv;lle, AR 72801 -
(Name and Address Of Plant)
: 3. Plant Unit        2      4. Owner and Certificate of Authorization (if required)                        N/A
: 5. Commercial Service Date                03/26/80        6. National Board Number for Unit                  22009 ASME    ASME                                                      Exam Cateaory item No    Comoonent or System                Exam No. Method Descriotion F-A      Fi.iOF      Reactor Coolant (Surge Line)      16-018      VT-3    Snubber 2BCA-1-H3 F-A      F 1.10F    Safety injection                  21-072      VT-3    Snubber 2CCA-21 H16 F-A      F 1.10F    Safety injection                  22-055      VT 3    Snubber 2CCA-22-H19 F-A      F 1.10F    Safety injection                  22-060    VT-3      Snubber 2CCA-22-H15 F-A      F 1.10F    Safety injection                  22-062      VT-3    Snubber 2CCA-22-H14 F-A      F 1.10F    Safety injection                  23-059    . VT-3    Snubber 2CCA-24-H15 F-A      F 1.10F - Safety injection                    24-076    VT-3      Snubber 2CCA-23-H27 F-A      F 1.10F    Shutdown Cooiing                  25-075      VT-3    Snubber 2CCA-25-H4 F-A      F 1.20A    High Pressure safety injection    80-548    VT-3      One-Way rsestraint 2DCB-501-(Detail 0) .
F-A      F 1.20A    High Pressure Safety injection    80-599    VT-3      One-Way Restraint 2DCB-3 H27 F-A      F 1.20A    Safety injection                  52-039    VT-3      One-Way Restraint 2GCB 5-H12 F-A      F 1.20A    Safety injection                  61-044    VT-3      One-Way Restraint 2GCB-7-H21 F-A      F 1.20A    Safety injection                  91 103    VT-3      One-Way Restraint 2GCB-9-H3 F-A      F1.20A      Safety injection                  91-111    VT-3      One-Way Restraint 2GCB-9-H11 F-A      F1.20A      Safety injection                  93-012    VT-3      One-Way Restraint 2HCB-23-H2 FA      F1.20A      Shutdown Cooling                  59-039    VT-3    - One-Way Restraint 2GCB-16-H21 FA      F 1.20A    Shutdown Cooling                  59-040    VT-3      One-Way Restraint 2GCB-16-H19                    I F-A      F 1.208    High Pressure Safety injection    80-556    VT-3      Multi-Directional Restraint 2DCB-500-PS-3/PG-32 F-A      F 1.208    High Pressure Safety injection    80 557    VT-3      Multi-Directional Restraint 2DCB-500-PS-3/PG-11 F-A      F 1.20B    High Pressure Safety injection    80-558    VT 3      Multi-Directional Restraint 2DCB-500-PS-5/PG-11 F-A      F 1.208    High Pressure Safety injection    81 237    VT-3      Multi-Directional Restraint 2CCB-70-H2O F.A      F 1.20B    High Pressure Safety injection    81-238    VT-3      Multi-Directional Restraint 2CCB-70-H21        4 F-A      F 1.20B    Safety injection                  52-037    VT 3      Multi-Directional Restraint 2GCB-5-H10 F-A      F 1.20B    Safety injection                  61-042    VT-3      Multi-Directional Restraint 2GCB-7-H7            l F-A      F1.20B      Safety injection                  93419      VT 3      Mutti-Directional Restraint 2HCB-23-H9 F-A      F 1.20C    Containment Spray                  76 047    VT-3      Variable Spnng 2GCB-11-H3 F.A      F1.20C      High Pressure Safety injection    80-545    VT 3      Variable Spring 2DCB-501-(Detail B)
F.A      F 1.20C    High Pressure Safety injectia      80-582    VT 3      Variable Spring 2DCB-1-H2 F-A      F 1.20C    High Pressure Safety injection 4,  81-223    VT-3      Variable Spring 2CCB 12-H007 F-A      F 1.20C    Safety injection                  54-034    VT-3      Variable Spring 2GCB-3-H13 F-A      F 1.20C    Safety injection                  91 108    VT-3      Variable Spring 2GCB-9-H8 F-A      F 1.20C    Shutdown Cooling                  59-038    VT-3      Vanable Spring 2GCB-16-H2O F-A      F 1.200    Main Steam                        18-019    VT-3      Constant Force Spong 2 EBB-1 A-H1 F-A      F 1.20E    Safety injection                  54-037    VT 3      Anchor 2GCB-3-H18 F-A      F1.20E      Safety injection                  91-113      VT 3    Anchor 2GCB-9-H13
* The examination volume / area of this component was not fully examined 100% due to an examination limitation.
The percentage of coverage achieved will be calculated and Relief Requests will be submitted as necessary.
AP&UEntergy by                            Date              Factory Mutual by q .g. [d Date 6/.43/9ry
                    'D.B;L0mbx                                                f J. O. Elliott, ANil EPG94013
 
Page 9 of 11 SUPPLEMENT TO FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS FOR ASME Code Class 1 (lWB), Class 2 (IWC), and Class 3 (IWD) Components and Their Supports (lWF)
Arkansas Power & Light Company /Entergy Operations, Inc.
P. O. Box 551, TCBY Building, Little Rock, AR 72203
: 1.        Owner (Name and Address of Owner)                                            l
: 2.        Plant Arkansas Nuclear One, Rt 3 B0x 137G, Russellville, AR .72801 (Name and Address of Plant)
: 3.        Plant Unit            2    4.      Owner and Certificate of Authorization (if required)                    N/A'
: 5.        Commercial Service Date                03/26/80      6. National Board Number for Unit                    22009 l
['                  ASME .ASME                                                                Exam                                                    !
Catenory item No                comoonent or System          Exam No. Method Descriotion l                  F-A            F 1.20F        Containment Spray            75-041      VT 3    Snubber 2GCB-10-H5 F-A            F 1.20F        Containment Spray            76-046      VT 3    Snubber 2GCB-11-HS i                  FA              F 1.20F        Containment Spray            78461      VT 3    Snubber 2HCB-15-H15 l                  F-A            F 1.20F        Main Feedwater -              17-029      VT-3    Snubber 2DBB-1-H4 l                  F-A            F 1.20F        Main Feedwater                17-037      VT-3    Snubber 20BB-1-H13 i                  F-A            F 1.20F        Main Feedwater                19-034      VT 3    Snubber 2DBB-2-H17 l                  F-A            F 1.20F        Main Steam                    18-024      VT  Snubber 2 EBB-1 A-H6                            ,
1                  F-A            F 1.20F        Main Steam                    65 038    _ VT-3  Snubber 2 EBB 2-H5 F-A            F1.20F          Shutdown Cooling            .57-025      VT-3    Snubber 2GCB-3-H22                              i F-A            F 1.30A        Emergency Feedwater          85-217      Vr-3    One Way Restraint 2DBC-2-H17 F-A            F 1.30A        Emergency Feedwater          85-220. VT-3 '  One-Way Restraint 2DBC-2-H2O j                  F-A            F 1.30A        Service Water                72 108      VT-3    One-Way Restraint 2HBC-83-H3
;                  F-A            F 1.30A        Service Water                72-139      VT 3    One-Way Restraint 2HBC-103-H16                  >
F-A            F1.30A          Service Water                72-141      VT-3    One-Way Restraint 2HBC-103-H19 F-A            F 1.30A        Service Water                73-111      VT 3    One-Way Restraint 2HBC 76-H14 F-A            F 1.30B        Ernergency Feedwater          85-215      VT 3    Mutti-Directional Restraint 2DBC-2-H15          5 F-A            F1.30B          Ernergency Feedwater          85-218      VT-3    Multi-Directional Restraint 2DBC-2-H18          *
!                  F-A            F1.30B          Ernergency Feedwater          85-703      VT-3    Multi-Directional Restraint 2DBC-7-PG-11        }
F-A            F1.308          Emergency Feedwater          94-037      VT 3    Multi-Directional Restraint 2HCC-282-H37 FA              F 1.30B        Emergency Feedwater          94-038      VT-3    Multi-Directional Restraint 2HCC-282-H38        i l                  F-A            F1.308          Service Water                71-020      VT 3    Multi-Directional Restraint 2HBC-34-H26          i
!                  F-A            F 1.30B        Service Water                71-022      VT-3    Multi-Directional Restraint 2HBC-34-H18 '        l
;                  F-A            F 1.30B        Service Water                72-109      VT-3    Multi-Directional Restraint 2HBC-83-H6            .
l-                  FA              F 1.300        Servce Water                  72-110      VT 3    Mutti-Directional Restraint 2HBC-83-H8            l
!                  FA              F1.30B          Service Water                72 112      VT-3    Multi-Directional Restraint 2HBC-83-H5 '          <
F-A            F 1.30B        Service Water                73-103      VT-3    Multi-Directional Restraint 2HBC-76-H11          l F-A            F 1.308        Servce Water                  73-104      VT-3    Multi . Directional Restraint 2HBC-76-H12          l i
F-A            F 1.30C        Service Water                72-132      VT-3    Variable Spring 2HBC-103-H5 F-A            F 1.30E        Servce Water                  72-111      VT 3    Anchor 2HBC-83-H7                                1 F-A            F 1.30E        Service Water                73-038      VT  Anchor 2HBC-43-H3                                  i F-A            F1.30F          Service Water                72 137      VT 3    Snubber 2HBC 103-H2O F-A            F 1.30F        Service Water                72-138      VT 3    Snubber 2HBC-103-H17 l-F-A            F 1.30F        Service Water                72-144A    VT-3    Snubber 2HBC-105-H27 F-A            F 1.30F        Servce Water                  72-159      VT 3    Snubber 2HBC-105-H14 l
* The examination volume! area of this component was not fully examined 100% due to an examination limitation.
The percentage of coverage achieved will be calculated and Relief Requests will be submitted as necessary.
1 AP&L/Entergy by                              J Date                Factory Mutual by 9.0.iHM                      Date 4//Jhp      l D.'B. Lom'ax                                    g J. O. Elliott. ANil EPG94013
 
Prgs 10 of 11 SUPPLEMENT TO FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS                                                  i FOR                                                                  <
ASME Code Class 1 (IWB), Class 2 (IWC), and Class 3 (IWD) Components and Their Supports (lWF)
Arkansas Power & Light Company /Entergy Operations, Inc.
: 1. Owner      P. O. Box 551. TCBY Building, Little Rock, AR 72203 (Name and Address of Owner)
: 2. Plant Arkansas Nuclear One, Rt 3 B0x 137G, Russellville, AR 72801 (Name and Address of Plant)
: 3. Plant Unit      2    4. Owner and Certificate of Authorization (if tequired)                'N/A
: 5. Commercial Service Date            03/26/80    6. National Board Number for Unit                22009 ASME      ASME                                                Exam Category item No    Component or System          Exam No. Method Description q
f',",    F1.30F    service Water                73-093B    VT.3      Snubber 2HBC-104-H18                                  l F-A.      F 1.40    HPsi Pump 2P89A              88-001      VT-3      Pump Support (s)
RG        1.14      Reactor Coolant Pump 2P32A    32-008      UT        Motor Flywheel Bore and Keyway                      .
RG        1.14      Reactor Coolant Pump 2P32A    32-009      UT,MT    Motor Flywheel- AccessiW Surfaces                  1 RG'        1,14      Reactor Coolant Pump 2P32C    33-008
* UT        Motor Flywheel- Bore and Keyway                    -
RG        1.14      Reactor Coolant Pump 2P32D    34-008
* UT        Motor Flywheel Bore and Keyway                      l I
I l
1 I
* The examination volume / area of this component was not fully examined 100% due to an examination limitation.
The percentage of coverage achieved will be calculated and Relief Requests will be submitted as necessary.
AP&L/Entergy by                          Date            Factory Mutual by 1. o. E/AM Date 4/#J/y
(/ J. O. Elliott, ANil
[ 5X Lom6x EPG94013
 
I Pag 311 of 11              i SUPPLEMENT TO FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS FOR
                          . ASME Code Class 1 (lWB), Class 2 (IWC), and Class 3 (LWD) Components and Their Supports (IWF)
Arkansas Power & Light Company /Entergy Operations, Inc.
: 1. Owner        P. O. Box 551. TCBY Building Little Rock, AR 72203 l
(Name and Address of Owner)
: 2. Plant Arkansas Nuclear One, Rt 3 Box 137G, Russellville, AR 72801 (Name and Address of Plant)
: 3. Plant Unit        2    4.      Owner and Certificate of Authorization (if required)            N/A l
l
: 5. Commercial Service Date            03/26/80      6. National Board Number for Unit          22009                  i 1
l          1S1 Pressure Tests:                                                                                                            ;
The following ISI pressure tests were completed this cycle of operation:
: 1. ASME Class 1 components (Category B-P) system leak test during 2R10.                                                      I l
: 2. Period pressure tests for the 2nd Interval,2nd Period, as follows-e  ECCS Recirculation Line (Test 1.29)
* ECCS Supply Line (Test 1.30)                                                                                          !'
l
* EFW-Loop A (Test 2.4) l
* EFW-Loop B (Test 2.5) l e  CVCS-BAM Gravity Feed / Emergency Boration (Test 2.11) l
* ECCS-RWT to Charging Suction (Test 2.18)
* ECCS-A LPSI Pump (2P-60M (Test 2.21) e  ECCS-B LPSI Pump (2P-608)(Test 2.22)
* ECCS-LPSI Discharge Headers (Test 2.23)
* Chill Water (Test 3.2) e  LTOP (Test 3.3) e    Letdown (Test 3.4) e    Charging (Test 3.5) e    Controlled Bleedoff (CBO) (Test 3.6) e  A and B Safety injection Tanks (Test 3.7) _
e    C and D Safety injection Tanks (Test 3.8)                                                                            l
* Component Coohng Water (Test 3 9) l                e    Blowdown Steam Generator A(Test 3.10) e    Blowdown Steam Generator B (Test 3.11) e    Main Steam Loop A (Test 3.12)
I                e    Main Steam Loop B (Test 3.13) l
* SDC/LPSI (2P-60A/B Suction) (Test 3.14)                                                                              l e    SDC/LPSI (Supply Headers)(Test 3.15) e  " Charging (In VCT Room)(Test 3.16)
                  . ECCS-HPSI Headers to RCS Hot Legs (Test 4.1) j                e    ECCS-HPSI Injection Lines (Test 4.2) i e    EFW Pen. 2P-35 to MFW Loop A (Test 4.3)
                  . EFW-Pen. 2P-65 to MFW Loop B (Test 4 4) e    MFW to Steam Gen. A (Test 4.5) e    MFW to Steam Gen B (Test 4.6)
AP&L/Entergy by          / J          Date              Factory Mutual by . O. /// h Date (,,/s 3/9q
                                    / D. [_o/nax -                                      J. O. Elliott, ANil j            EPG94013 ~
I
 
4 i
      . g .s A -.s a..
                            ;;w . s . . . . . . . . . . w 4s. N xa.  -,      s - -' " .-      -
                                                                                                                -c    <    s  ..  ..:.....y . . -    3"'-                l l )%siss!A,*.
a td we , - . .c.%cc%IS[C5ii:gss[Ex!ni.ihif,.x..n/In,.,spsethgg,.
e              nu .~ . . . . s .w.      >
i
                                                                                ,                .... .a              osi
                                                                                                                        -e    Sumnisfy~W a us          >    +a GOk.%.Wys.tigl N        O
                                                                                                                                                      -h              !.
ASME                                O  G      T                            ibggggg (
l 151 Eram No.                                                              Code          Nondestructive      R  E H Examination Area Description                                          Category          Examinations        E O E Component / Piping Line No.                                          Item No.            Performed        C M R                                Remarks 32-008                                                                RG              UT45* Tangent        9 0 0              The RCP 2P32A motor was Motor Flywheel- Bore and Keyway                                        1.14                                                    replaced during 2R9. The bore            )
i RC Pump 2P32A                                                                                                                  and keyway regions of this              .
replaced motor flywheelwere              I examined in the shop Non-Outage.
32-009                                                                RG              MT                    E O O              The RCP 2P32A motor was Motor Flywheel- Entire Flywheel                                        1.14          UT0" Lam Scan        O O 9              replaced during 2R9. The entire RC Pump 2P32A                                                                          UT45" Tangent        9 O O - accessible surface of this replaced motor flywheel was examined in the shop Non-Outage. Two NB-2530 (Section Ill) acceptable l                                                                                                                                lamination indications were recorded with the UT0" Lam Scan.
71-020                                                                F-A            VT-3                  O O 9              IRF 6671 evaluated a Non-Outage Multi-Directional Restraint 2HBC-34-H26                              F 1.30B                                                  reported condition of significant 2HBC-34-20"                                                                                                                    support corrosion. This was verified by a field walkdown. The evaluation concluded that the
;                                                                                                                                support will serve its intended design function and remains operable per CR 2-93-0026.
71-022                                                                F-A            VT-3                  0 0 9              IRF 6669 evaluated a Non-Outage l  Multi-Directional Restraint 2HBC-34-H18                                F1.30B                                                  reported condition of significant l  2HBC-34-20"                                                                                                                    support corrosion. This was verified by a field walkdown. The evaluation concluded that the support will serve its intended design function and remains operable per CR-2-93-0025.              !
71-022W                                                                D-B            VT-3                  2 00              Inspection performed Non-Outage.
Integrally Welded Attachment 2HBC-34-H18                              D 2.20 2HBC-34-20" l
 
                                                                                                                                        \
        ,,--e          .                                                                -          . , .      .
n      i
  ,_ ; nA
  @n    y.NO'2;1S1
              ~7    agg    C.,:n_,,t,E,x,m,,azanw mp,o,n,en
                              ;      g;  ,;g    .      /lcspe,n tt n. g.    . c,t.,- iona Sum.mg  x,2R10W, nw ary ag g gg 3.m N ,%;          ,_gu        sA gg
                                                                                                                    -        ~
z    i N      O                        ,
                                                                                                                                  #      1 ASME                                O  G  T                        gg.. gy
                                                                                                                      ~
ISI Exam No.                                  Code        Nondestructive        'R  E H Examination Area Description                Category      Examinations          E O E Component / Piping Line No.                Item No.        Performed            C M R                      Remarks 02-001                                      B-A        MT(Initial)              9 0 0        one Code-acceptable indication Flange To Pcci Segment Torus                B 1.40    UT35* Shear-Axial O O O                recorded with the IR35' Reactor Closure Head                                  UT45* Shear-Axial 9 OO                Shear-Axial Scan during 2R10.
UT45* Shear-Cire          9 OO        This slag indication is of an UT60* Shear-Axial 9 OO                acceptable size per Table IJT60* Shear-Cire        9 O O        IWB-3510-1.
02-B-085                                  B-G-2      VF-1                      9 00        Inspection performed 2R10.
Instrument Nozzle Flange Bolting          B 7.10 Reactor Closure Head 02 B-086                                  B-G-2      VF-1                      9 OO        Inspection perfonned 2R10.
I  Instrument Nozzle Flange Bolting          B 7.10 I  Reactor Closure Head 02-B-087                                  B-G-2      VT-1                      9 0 O        Inspection performed 2R10.
Instrument Nozzle Flange Bolting          B 7.10 Reactor Closure Head 03-034                                    C-B        MT(Initial)              O O-9        Two linear surface (MT)
Main Steam Nozzle To Top Head Dome        C 2.21    MT(Reinspection)          9 OO        indications recorded during 2R10.
Steam Generator 2E24 A                              UT0* DAC Scan            9 OO        The indications were remosed by UT35* Shear Axial 9 0 O                light grinding and the subsequent l                                                        UT35' Shear-Cire          9 OO        reexamination revealed no UT45* Shear-Axial 9 0O                recordable indications (IRF 7188).
UT45' Shear-Cire          9 OO UT60 Shear-Axial O OO UT60* Shear-Cire          9 O O 03-035                                    C-B        UT60* Shear-Axial O O O                This examination was performed Feedwater Nozzle To Upper Shell          C 2.21                                            2R10 as a successive examination Steam Generator 2E24 A                                                                      perIWC-2420(b). The reexamination of the slag              .;
indication detected 2R9 restaled no flaw growth.
03-042                                    C-B      UT60* Skewed              9 O O        Examination performed 2R10.
Main Steam Nozzle Inner Radius Section    C 2.22 Steam Generator 2E24 A 04-03 $                                    C-B      MT(Initial)              9 OO        Examination performed 2Rio as Main Steam Nozzle To Top Head Dome        C 2.21                                          an additional examination per Steam Generator 2E24B                                                                      IWC-2430(a). This examination, performed as a result of the linear surface (MT) indications recorded on 03-034, revealed no recordable indications.
05-009                                    B-D        UTO DAC Scan            9 0 0        Examination performed 2R10.
12" Surge Nozzle To Bottom Head Weld      B 3.110 UT35 Shear-Axial 9 0 0 Pressurizer Vessel                                    UT35 Shear-Cire          9 0 0 UT45* Shear-Axial 9 0 0 UT45* Shear-Cire        9 O O UT60* Shear-Axial 9 O O UT60* Shear-Cire        2 O O                                            I
 
  +hfXNdl21SfC              # > 6s sips      sit [$l,adiiMUnn/InSgisinMSimidait.mN2kl0YNhiDunfjJ@@![@p%
4      wer>      e <.a c s.              -
e-        x - me - -    e - -
                                                                                -m      u mm e%%
N        O                                                        y ASME                        O    G  T                        fyggy/
ISI Exam No.                                    Code      Nondestructive  R    E H Examination Area Description                  Category      Eraminations    E    O E Component / Piping Line No.                  Item No.      Performed      C M R                      Remarks 05-012                                        B-D        UT0* DAC Scan    9 O O          Exanunation performed 2R10.
6* Safety Nozzle To Top Head Weld @ 60*      B 3.110 UT45* Shear Axial 9 OO Pressurizer Vessel                                      UT45* Shear-Cire 9 O O UT60 Shear-Axial O O O UT60* Shear-Cire 9 O O 05-013                                      B-D        UT0* DAC Scan    9 OO          Examination performed 2R10.
6" Safety Nozzle To Top Head Weld @ 270*    B 3.110 UT45* Shear-Axial 9 O O Pressurizer Vessel                                      UT45* Shear-Cire  9 OO UT60* Shear-Axial 9 OO UT60* Shear Cire  9 OO 05-120                                      B-D        UT45* Skewed      9 OO          Examination performed 2R10.
12" Surge Nozzle Inner Radius                B 3.120 UT60* Skewed        9 OO Pressurizer Vessel 05-123                                        B-D      UT45 Skewed        9 00          Examination performed 2R10.
6" Safety Nozzle Inner Radius @ 60*          B 3.120 UT60* Skewed        9 OO Pressurizer Vessel 05-124                                        B-D      UT45" Skewed      9 OO          Examination performed 2R10.
6" Safety Nozzle inner Radius @ 270*          B 3.120 UT60* Skened        9 0 0 Pressurizer Vessel 16-001                                      B-F      PT(Initial)        9 OO          Examination performed 2R10.
Hot Leg Nozzle To Surge Line Safe End        B 5.130 UT45* RLong-Axial O 9O Circumferential Weld                                  UT45* RLong-Circ 9 00 2BCA 1-12" 16-003                                      B-J        PT(Initial)      9 0 0        An augmented volumetric Pipe To Elbow Circumferential Weld          B 9.11    UT45* RLong-Axial O EO          examination was performed 2R10 2BCA-1-12"                                              UT45* RLong-Cire 9 OO          in response to NRCB 88-11. No evidence of thermal stratification induced fatigue cracking was detected. Code credit also taken.
Additionally, the base metal of the entire elbow was also examined.
16-004                                      B-J      PT(Initial)      9 OO          An augmented volumetric l  Elbow To Pipe Circumferential Weld            B 9.11    UT45* RLong-Axial O O O        examination was performed 2R10 l  2BCA-1-12"                                              UT45* RLong-Cire 9 0O            in response to NRCB 88-11. No
;                                                                                          evidence of thermal stratification l                                                                                            induced fatigue cracking was l                                                                                            detected. Code credit also taken.
I Additionally, the base metal of the entire elbow was also examined.
l 16-011                                      B-J      PT(Initial)      9 O O          An augmented volumetric Pipe To Elbow Circumferential Weld          B 9.11    UT45* RLong Axial O 9 O          examination was performed 2R10 2BCA-1 12"                                            UT45* RLong-Cire 9 OO            in response to NRCB 88-11. No evidence of thermal stratification i                                                                                            induced fatigue cracking was detected. Code credit also taken.
Additionally, the base metal of the l entire elbow was also examined.
i I
r
 
l                                                                                                                              l
!                                                            ~
          ,,n~-,..,~        :..  .
                                          ,.~ a                        &,          . v . . ~. , n , 4g + ggww                  l
  $$MpySLLC mponentExa4m..x                      mination
                                                        /tspecten;Summar_yg2R10i&ggnp0 igg;eppgy ASME O  G T                    b 5N$tu
                                                                                                            $g3g3 ISI Exam No.                                        Code    Nondestructive R  E H Examination Area Description                    Category    Examinations  E  O E Component / Piping Line No.                      Item No.      Performed    C M R                    Remarks i  16-012                                          BJ      PT(Initial)      O OO        An augmented volumetric l Elbow To Pipe Circumferential Weld              B 9.11  UT45* RLong-Axial O 9O        examination was performed 2R10 2BCA 1-12"                                              UT45* RLong-Circ 0 0O        in response to NRCB 88-11. No evidence of thermal stratification induced fatigue cracking was detected. Code credit also taken.    ;
Additionally, the base metal of the  l j                                                                                        entire elbow was also examined.
16-014                                          B-F      PT(Initial)      E O O      Examination performed 2R10.
Safe End To Pressurizer Surge Nozzle            B 5.40  UT45* RLong-Axial O 9O                                              !
l  2BCA 1-12"                                              UT45* RLong-Cire O O O                                              l l  16-018                                        F-A      VF-3              8 OO        Inspection performed 2R10 by
                                                                                                                                )
Snubber 2BCA 1-H3                              F1.10F                                Snubber Group.                        !
2BCA-1-12" 17-001                                          C-F-2  U f45' Shear-Axial O E O      An augmented volumetric              l E OO Transition Piece To Steam Generator Nozzle      C 5.51  UT45* Shear-Cire              examination was performed 2R10 l
2DBB-1-18"                                              UT60* Shear-Axial 8 OO        in response to NRC IN 93-020. Nc l                                                                                        evidence of thermal stratification    )
l                                                                                        induced fatigue cracking was          ;
detected. The exam volume was        ;
expanded to capture counterbore      !
regions.                              j 17-002                                          C-F-2  UT45* Shear Axial O 9 8      An augmented volu. metric            I Pipe To Transition Piece Circumferential Weld  C 5.51  UT45* Shear-Circ  8 OO        examination was performed 2R10        1 2DBB-1-18"                                              UT60* Shear-Axial 9 OO        in response to NRC IN 93-020. Nc      l l
evidence of thermal stratification induced fatigue cracking was detected. The exam volume was expanded to capture counterbore raions. (Code-acceptab!c            j inclusion)                          i 17-003                                          C-F-2    UT45 Shear Axial O OO        An augmented volumetric
;  Reducing Elbow To Pipe Circumferential Weld    C 5.51  UT45* Shear-Cire O O O        examination was perfonned 2R10 l  2DBB-1-18"                                              UT60* Shear-Axial O OO        in response to NRC IN 93-020. Nc evidence of thermal stratification induced fatigue cracking was detected. The exam volume was l                                                                                          expanded to capture counterbore
;                                                                                          regions.
17-029                                        FA        VT 3            9 0 O        Inspection performed 2R10 by l  Snubber 2DBB-1-H4                              F1.20F                                Snubber Group.
!  2DBB-1-24"
!    17-037                                          F-A      VT-3            9 OO        Inspection performed 2R10 by l
Snubber 2DBB 1-H13                              F1.20F                                Snubber Group.
2DBB-124" 18-001                                        C-F-2    MT(Initial)    8 OO          Examination performed 2Rlo.
,  Steam Generator Nozzle To Nozzle Extension      C 5.51  UT45* Shear-Axial 8 00 i
    ' EB B.1 -36"                                            UT45 Shear-Cire  8 0 0                                          :
l t
w                                            w
 
h!kkhhkIISkkhNkNNam,ihkhb/IkspkkkShm Akum r                sw ~ su we ' an + y:              -
: a. a    we      rfn*2Nihfdk k i xe xwn knab.s  h hh[ Af hh N      O                      WWM" ASME                      O                              W2nd Period G  T                      %m kw.%,
ISI Exam No.                                      Code    Nondestructive R  E H Examination Area Description                    Category    Examinations  E  O  E Component / Piping Line No.                    Item No.      Performed  C M R                    Remarks I
18-002                                        C-F-2    MT(Initial)      9 0 0      Examination performed 2Rio.            j Steam Generator Nozzle Extension To Reducer    C 5.51  UT45' Shear-Axial O 9 O                                            I 2 EBB 1-36"                                            UT45* Shear-Cire  9 O O 18-003                                        C-F 2    MT(Initial)      B D D      Examination performed 2R10.
Reducer To Elbow Circumferential Weld          C 5.51  UT45* Shear-Axial O 9 O 2 EBB-1-38"                                            UT45* Shear-Cire  B O O 18-005                                        C F-2    MT(Initial)      9 0 0      Examination performed 2R10.
Elbow To Pipe Circumferential Weld            C 5.51  LTr45' Shear-Axial 9 O O 2 EBB-1-38"                                            UT45' Shear-Circ  9 O O 18-019                                        F-A      VT-3              O O 9      1RF 7182 evaluated a 2R10 Constant Force Spring 2 EBB-1 A-H1            F 1.20D                              reported unacceptable spring load 2 EBB 1-38"                                                                          setting. A field walkdown determined that the position scale
;                                                                                      indicator reflects design travel instead ofload setting. The i                                                                                      evaluation concluded that the I                                                                                      position scale reading is acceptable.
18-019W                                        C-C    MT(Initial)      9 O O      Examination performed 2R10.
Integrally Welded Attachment 2 EBB-1A-H1      C 3.20 2 EBB-1 38"                                                                                                                ,
18-024                                        F-A    VF-3              8 O O      Inspection performed 2R10 by l  Snubber 2 EBB-1 A-H6                          F1.20F                              Snubber Group.
I  2 EBB-1-38" 19-001                                        C-F-2  UT45* Shear-Axial O 9 O      An augmented volumetric Transition Piece To Steam Generator Nozzle    C 5.51  UT45' Shear-Circ  9 O O      examination was performed 2R10 2DBB-2-18"                                            UT60' Shear-Axial 9 O O      in response to NRC IN 93-020. Nc      l cvidence of thermal stratification    i induced fatigue cracking was          ,
detected. The exam volume us expanded to capture counterbore regions.
19-002                                        C F-2  UT45' Shear-Axial O 9 O      An augmented volumetric Pipe To Transition Piece Circumferential Weld  C 5.51  UT45' Shear-Cire  9 OO        examination was performed 2R10 2DBB-2-18"                                            UT60* Shear-Axial 9 O O      in response to NRC IN 93-020. Nc l                                                                                        cvidence of thermal stratification induced fatigue cracking was detected. The exam volume was expanded to capture counterbore      ,
l                                                                                        regions.
19-003                                        C-F-2  UT45' Shear-Axial O 9 O      An augmented volumetric Reducing Elbow To Pipe Circumferential Weld    C 5.51  UT45' Shear-Cire 8 O O      examination was performed 2Rio        '
2DBB-2-18"                                            UT60* Shear-Axial 9 O O      in response to NRC IN 93-020. Nc evidence of thermal stratification induced fatigue cracking was detected. The exam volume was
!                                                                                        expanded to capture counterbore .
regions.                          l i
 
EMAN62fil$iidIn$ema n s9memm            ,- n m i"EssiEE        um ~ mh , < mm - - $aaemymoum EIEin/IW5ctii6Snisks*%5NI6?$iNp!60is[*s@mg&;&g n
gpy Et i
j                                                  ASME                      O    G  T                      N$gg.          '
ISI Eram No.                                    Code    Nondestructive  R    E H l  Excmination Area Description                Category    Examinations    E O E                                              1 l
Component / Piping Line No.                  item No.      Performed      C M R                        Remarks 19-034                                      F-A      VT-3              O O E      The inspection performed 2R10 by Snubber 2DBB-2-H17                          F1.20F                                    the Snubber Group revealed a loosc  !
2DBB-2 24"                                                                            jam lock nut forward assembly.      li The locking ring was tightened.
21-072                                      F-A      VT 3              O O E        The inspection performed 2R10 by    i Snubber 2CCA-21-H16                        F1,10F                                    the Snubber Group reported that      ,
2CCA-21-8"                                                                            the position tube indicator appeared to be making contact with the face of the clevis. Per evaluation, the clearance is adequate due to minimal hanger movement.
22-001                                      B-F      PT(Initial)        E O O        Examination perfonned 2R10.
Safe End To Nozzle Circumferential Weld    B 5.130 UT45' RLong-Axial 9 O O.
2CCA-22-12"                                          UT45' RLong-Circ E O O 22-012                                      B-J      PT(Initial)        E O O        Examination performed 2R10.
Elbow To Pipe Circumferential Weld          B 9.11  UT45* Shear-Axial E O O-2CCA-22-12"                                          UT45' Shear-Cire  E .. O - 0 22-013                                      B-J      PT(Initial)        9. O O      Examination performed 2R10.
Pipe To Elbow Circumferential Weld          B 9.11  UT45' Shear-Axial O O O t
2CCA-22-12"                                          UT45* Shear-Cire  B O O                                            i l
l    22-016                                      B-J      PT(Initial)      .E'OO        Examination performed 2R10.
Elbow To Pipe Circumferential Weld          B 9.11  UT45* Shear-Axial 9OO                                                .
2CCA 22-12"                                          UT45' Shear-Cire  E O O                                            )
22-018 -                                    B-J      PT(Initial)        B O O        Examination performed 2R10.
Elbow To Pipe Circumferential Weld          B 9.11  UT45* Shear-Axial B DO                                                ,
2CCA-22-12"                                          UT45' Shear-Circ  2 O O.                                            l 22-019                              .
BJ      PT(Initial)        E.O O        Examination performed 2R10.
Valve To Elbow Circumferential Weld          B 9.11  UT45' Shear-Cire  E O O.
2CCA 22-12"                                          UT60* St:ar-Axial O E O-22-024                                    . B.J      PT(Initial)        E O O - Examination perfonned 2R10.
Pipe To Tee Circumferential Weld            B 9.11  UT45* Shear-Circ  E O O                                              l j    2CCA-22-8"                                          UT60* Shear-Axial Z O O                                              !
22-025                                      B-J      PT(Initial)        EO O          Examination performed 2R10.
Elbow To Pipe Circumferential Weld          B 9.1I  UT45* Shear-Cire  E O O 2CCA-22-8"                                          UT60* Shear-Axial Z O O 22-026                                      B-J      PT(Initial)        E O O        Examination performed 2R10.          ,
Pipe To Elbow Circumferential Weld          B 9.11  IJf45' Shear-Cire  E OO 2CCA-22-8"                                          UT60* Shear-Axial O E O 22-041                                      B-J      PT(Initial)        E OO          Examination performed 2R10.
Elbow To Pipe Circumferential Weld          B 9.21 2CCA-22-3" 22-053                                      F-A      VT-3              2 O O        Inspection performed 2R10.
Variable Spring 2CCA 22-HI                  F 1.10C 2CCA 22-12" 22-054                                      F-A      VT-3              9 O O        Inspection performed 2R10.
One-Way Restraint 2CCA-22-H2O                F 1.10A 2CCA-22-12"
 
  . '+                              +- nya  wa      ..    :.        r,. .c - -              m yANO;2(ISIC W@ggy.a..w.~          ~mm:6ini..pnsat n :::.-a s-Exami g.w        /kspec,..,if
:.atitha..      t ri Sunimsrfj;2"x~w  R 1 0 %. w % Q u-a.: w S.Q pN'6n wxm.w              m.              -
2s an= m m          - =:..-    i w ~ ~ umn ..%w N        O                      E%NOTW ASME                              O    G  T                        Rg m a ISI Exam No.                                    Code          Nondestructive    R    E H Examination Area Description                  Category        Esaminations      E    O E Component / Piping Line No.                  Item No.          Performed        C M R                      Remarks 22-055                                        F-A          VT-3                  0 0 0        Inspection performed 2Rio by Snubber 2CCA-22-H19                          F1.10F                                          Snubber Group.
2CCA-22-12" 22-060                                        F-A          VT3                    9 O O        Inspection performed 2R10 by Snubber 2CCA-22-H15                          F1.10F                                          Snubber Group.
2CCA 22-12" 22-062                                        F-A          VT-3                  8 O O        Inspection performed 2R10 by Snubber 2CCA-22-H14                          F1.10F                                          Snubber Group.
2CCA-22-12" 22-063                                      F-A          VT-3                  0 0 O        Inspection performed 2R10.
Variable Spring 2CCA-22-H4                  F 1.10C 2CCA-22-8" 22-070                                      FA          VT-3                  9 O O        Inspection performed 2R10.
One-Way Restraiat 2CCA-22-H8                F 1.10A 2CCA-22-3" 22-071                                      F-A          VT-3                  O O 8        IRF 7183 evaluated a 2R10 One-Way Restraint 2CCA-22-H7                F 1.10A                                          reported condition of a conduit 2CCA-22-3"                                                                                    found in contact with the support.
This was verified by a field walkdown. The evaluation concluded that the conduit las no adverse affect on the support and this condition is acceptable.
22-071W                                      B-K 1        PT(Initial)            9 0 0        Examination performed 2R10.
Integrally Welded Attachment 2CCA-22 H7      B 10.10 2CCA-22-3" 23-059                                      F-A          VT-3                  O O 9        Theinspection performed 2R10 by Snubber 2CCA 24-H15                          F1.10F                                          the Snubber Group revealed 2CCA-24-12"                                                                                  cracked grout dislodged from around the wall mounted base plate. The base plate grouting was repaired.
24-031                                      B-J          PT(Initial)            B OO        Examination performed 2R10.        !
Elbow To Pipe Circumferential Weld          B 9.11      UT45 Shear-Cire        B D O 2CCA-23-8"                                                UT60* Shear-Axial O 9 0                                                1 24-032                                      B-J          PT(Initial)            B D O        Examination performed 2R10.        l Pipe To Elbow Circumferential Weld          B 9.11      1.Tf45* Shear-Cire    8 OO                                            l 2CCA-23-8"                                                UT60* Shear-Axial B O O 24-033                                      B-J          PT(Initial)            9 O O        Examination performed 2R10.
Elbow To Pipe Circumferential Weld          B 9.11      UT45* Shear-Circ      E O O 2CCA-23-8"                                                UT60 Shear-Axial 9 O O 24-047                                      B-J          PT(Initial)            O O 8        Linear surface (PT) indicat2ons Elbow To Pipe Circumferential Weld          B 9.11      PT(Reinspection)      8 O O        were detected during 2Rio. These 2CCA-23-6"                                                UT45 Shear-Cire        Z O O        indications were non-service UT60* Shear-Axial B O O            induced (undercui). The indications were removed by        I surface preparation and the        ,
subsequent reexamination revealed- l no recordable indications.          I
 
y#, y9XNUMsIS.lD=$ni,  :        , pbs.ni8$h mins (if h/I,ns p,ecliin' w Sunim,fy2 Q,      .n    ;-
i a.mf M R10T$3<m!60tkF*Wg, N          O                      WWW 925PJeriod ASME                      O    G    T                      y ; ggp ISIExam No.                                    Code    Nondestructive  R    E H Examination Area Description                Category  Examinations    E    O    E Component / Piping Line No.                  Item No. Performed      C M R                      Remarks l
24-050                                      B-J      PT(Initial)      9 0 0        Examination performed 2R10.
Pipe To Reducer Circumferential Weld        B 9.21 2CCA-23-3" 24-076                                      F-A      VT-3              9 OO          Inspection performed 2R10 by Snubber 2CCA 23-H27                        F 1.10F                                  Snubber Group.
l  2CCA-23-12" 24-078                                      F-A      VT-3              0 0 0        1RF 7184 evaluated a 2R10 Variable Spring 2CCA-23-H4                  F 1.10C                                  reported condition of the spring 2CCA 23-8"                                                                          can in contact with a wall. This was verified by a field walkdown.
The evaluation concluded that the rod has sufficient clearance for the anticipated movements and the condition is acceptabic.
24-081W                                    B-K-1    PT(Initial)      9 OO        Examination performed 2R10.
l  Integrally Welded Attachment 2CCA-23-H22    B 10.10 2CCA 23-8" 24-083                                      F-A      VT-3              9 O O        Inspection performed 2R10.
Variable Spring 2CCA 23-H7                  F 1.10C 2CCA-23-8" 24-085                                      F-A      VT-3              O O E        IRF 7185 evaluated a 2R10 Variable Spring 2CCA-23-H8                  F 1.10C                                  reported condition of an adjacent 2CCA-23-8"                                                                          pipe interfering with a hanger rod.
This was verified by a field walkdown. The evaluation concluded the support is not impeded from supporting the design loads and the condition is acceptable.
24-086                                      F-A    VT-3              8 OO          Inspection performed 2R10.
One-Way Restraint 2CCA-23-H24              F 1.10A 2CCA-23-6" 25-017                                      B-J    UT45' Shear-Axial 9 0 0        An axial scan direction volumetric Tee To Pipe Circumferential Weld            B 4.5  UT60" Shear-Axial 9 00          examination was performed 2R10 2CCA-25-14"                                                                          in response to ist Interval Relief Request B-J/B4.5. Due to the support design only the bottom hall of the in'terfering pipe clamp could be removed. Axial scan coserage achieved - 56%.
25-075                                      F-A    VT-3              9 0 0        Inspection performed 2R10 by Snubber 2CCA-25-H4                          F1.10F                                  Snubber Group.
2CCA-25-14" 26-024                                      F-A    VF-3              8 00        Inspection performed 2R10 by Snubber 2CCA-14-H2                          F 1.10F                                Snubber Group.
2CCA-14-3"
 
T. MN,dd.,
        , - .      I,S,M.xiriji6iisif,Eisinin.
g    +;.    . - . .
                                                    . , ,siisidInSpestistfSurnNNtM.Nhi$fN36(6iif[$$3
                                                              . ,        .. , ,n , ,_  ._a ,,,, , n,,g,              ,,g.,
N        O                                    Y ASME                            O                                  If G  T                      fg.ggy3 ISI Exam No.                                  Code        Nondestructive    R    E H Examination Area Description                Category        Examinations      E O E Component / Piping Line No.                  Item No.          Performed      C M R                      Remarks 26-028                                      F-A          VT-3                8 0 O        Inspection perfonned 2Rio by Snubber 2CCA-15-H9                          F1.10F                                        Snubber Group.
2CCA-15-3" 26-030                                      F-A          VF-3                9 O O        Inspection performed 2R10 by Snubber 2CCA-15-H27                        F 1.10F                                        Snubber Group.
2CCA-15-3" 26-031                                      FA          VT-3                9 O O        Inspection performed 2R10 by Snubber 2CCA-15-H26                        F1.10F                                        Snubber Group.
2CCA-15-3" 26 053                                      F-A          VT-3                9 OO          Inspection performed 2R10 by Snubber 2CCA-14-H5                          F1.10F                                        Snubber Group.
2CCA-14-3" 26-054                                      FA          VT 3                O O E        The inspection performed 2R10 by Snubber 2CCA-15-H45                        F1.10F                                        the Snubber Group revealed a loosc 2CCA-15-3"                                                                                locking collar allowing the end connector to rotate freely. This snubber was replaced by 2R10 scheduled LCP 92-6020.
26-055                                      F-A          VF3                9 O O        Inspection performed 2R10 by Snubber 2CCA-15-H44                        F1.10F                                        Snubber Group.
2CCA-15-3" 26-060                                      F-A                                                                              '
VF-3                9 O O        Inspection performed 2R10 by Snubber 2CCA-15-H41                        F1.10F                                        Snubber Group.
2CCA 15-3" 26-062                                      F-A        VF-3                9 O O        Inspection performed 2Rio by        ,
Snubber 2CCA-15-H39                          F 1.10F                                      Snubber Group.                      i 2CCA-15-3"                                                                                                                      i 27-030                                      F-A        VT-3                9 O O        Inspection performed 2R10 by Snubber 2CCA-13-H4                          F 1.10F                                      Snubber Group.                      ,
2CCA-13-3"                                                                                                                      j 27-034                                      F-A        VF-3                9 0 O        Inspection performed 2R10 by Snubber 2CCA-15-H24                          F1.10F                                        Snubber Group.
2CCA-15-3" 27-067                                      F-A        VF-3                9 O O        Inspection performed 2R10 by Snubber 2CCA-15-H60                        F 1.10F                                        Snubber Group.
2CCA-15-4" 27-074                                      F-A        VT-3                9 0 0        Inspection performed 2R10 by Snubber 2CCA-15-H56                        F l.10F                                        Snubber Group.                      l 2CCA-15-3"                                                                                                                    l 27-076                                      F-A        VT-3                9 OO          Inspection perfcrmed 2R10 by Snubber 2CCA-15-H53                        F 1.10F                                        Snubber Group.
2CCA-15-3"                                                                                                                  ,
27-078                                      F-A        VF-3                0 0 0        Inspection performed 2R10 by      :
Snubber 2CCA-15-H50                        F 1.10F                                        Snubber Group.                    i 2CCA-15-3" 27-081                                      F-A        VT-3                8 0 0        Inspection performed 2R10 by Snubber 2CCA-15-H48                        F 1.10F                                        Snubber Group.                    l 2CCA-15-3"
 
4 k~fhkNhh.ww
      ~r    n            -kNI us, isBenn~
n: ,    ,nw aaisirisusii/inpeeusii3unaniiygi,h6%R
                                              - <- .            &      w  w>n ,,              36tn@w__.. ,pjn w:maukgm-                  _
a*
N        O                      NW"%
MMJgygod AShiE                    O      G  T                      ysqgg ISI ham No.                                        Code    Nondestructive R      E H Examination Area Description                    Category  haminations    E O E Component / Piping Line No.                      Item No. Performed    C M R                        Remarks 28-008                                          B-J      PT(Initial)      8 0 0          Examination performed 2R10.
Elbow To Pipe Circumferential Weld              B 9.11  UT45* Shear Axial 9 00 2CCA-15-4"                                                UT45' Shear-Cire B O O 28-009                                          B-J      PT(Initial)_    9 OO          Examination performed '!RIO.
Pipe To Elbow Circumferential Weld              B 9.11  UT45* Shear-Axial OOO 2CCA-15-4"                                              UT45* Shear-Cire B O O 28-033                                          F-A      VF-3            8 O O          Examination performed 2R10.
One-Way Restraint 2CCA-15-H14                  F 1.10A 2CCA-15-4" 28-034                                          F-A      VT-3            8 0 0          Examination performed 2R10.
Multi-Directional Restraint 2CCA-15-H13        F1.10B 2CCA-15-4"                                                                                                                !
1 28-035                                          F-A    VT-3            9 OO          Examination performed 2R10.      l Variable Spring 2CCA-15-HI                      F1.10C                                                                    ,
I 2CCA-15-4" 28-036                                          F-A    VT-3              8 OO          Inspection performed 2R10 by Snubber 2CCA-15-H29                              F 1.10F                                Snubber Group.                    i 2CCA-15-4" 28-037                                          F-A    VT-3              0 08          The inspection performed 2R10 by Snubber 2CCA-15-H30                            F1.10F                                  the Snubber Group revealed over 2CCA-15-4"                                                                              %" play at the pipe clamp attachment & cracked grout at the wall mounted base plate. The spacing was corrected and grout  ,
repaired. This snubber was replaced by 2R10 scheduled LCP  l 92-6020.                        l 28-041                                          B-J    PT(Initial)      9 OO          Examination performed 2R10.
Tee To Reducer Circumferential Weld            B 9.21 2CCA-15-3" 28-042                                          B-J    PT(Initial)      9 0 0          Examination performed 2R10.
Elbow To Tee Circumferential Weld                B 9.21 2CCA-15-3" 28-043                                          B-J    PT(Initial)      9 O O          Examination performed 2R10.
Pipe To Elbow Circumferential Weld              B 9.21 l
2CCA-15-3" 28-044                                          B-J    PT(Initial)      O OO            Examination performed 2R10.
Elbow To Pipe Circumferential Weld              B 9.21 2CCA-15-3" 28-045                                          B-J    PT(Initial)      9 0 0          Examination performed 2R10.
Pipe To Elbow Circumferential Weld              B 9.21 2CCA-15-3" 28-046                                          B-J    PT(Initial)      8 O O          Examination performed 2R10.
Valve To Pipe Circumferential Weld              B 9.21 2CCA 15-3" 28-047                                          B-J    PT(Initial)      B O O          Examination performed 2R10.
Pipe To Valve Circumferential Weld              B 9.21 2CCA-15-3"
 
  < ygggggfC?b
        ,.= ~            'ios.d%-35 wy l,m  sani $atiin/InspScE,n
                                                      ~ - z 2    ~4      Sussissrymm iN wywmmweb 1.0%NE $6$1@ ' :
N      O                      U              i ASME                              O  G T hn$N@U$ q g --
                                                                                                              "q aPiribd~
ISI Eram No.                                    Code    Nondestructive          R  E H Examination Area Description                Category    Examinations          E  O  E Component / Piping Line No.                  Item No. Performed            C M R                  Remarks 28-048                                      B-J      PT(Initial)              @OO      Examination performed 2R10.
Elbow To Pipe Circumferential Weld          B 9.21 2CCA-15-3" l  28-049                                      B-J      PT(Initial)              9 O O    Examination performed 2R10.
l  Pipe To Elbow Circumferential Weld          B 9.21 2CCA-15-3" l
28-054                                      F-A      VT-3                      @OO      Inspection performed 2R10 by l  Snubber 2CCA-15-H31                        F 1.10F                                    Snubber Group.
j  2CCA-15-4" 28-056                                      F-A      VT3                      9 O O    Inspection performed 2R10 by Snubber 2CCA-15-H34                        F1.10F                                      Snubber Group.
2CCA-15-3" 28-058                                      F-A    VT-3                      8 0 0    Inspection performed 2R10 by Snubber 2CCA-15-H36                          F1.10F                                    Snubber Group.
l
;  2CCA-15-3" l  29-028                                      F-A    VT-3                      8 O O    Inspection performed 2R10 by l  Snubber 2CCA-16-H1                          F1.10F                                    Snubber Group.
2CCA-16-2" 29-036                                      F-A    VT-3                      9 O O    Inspection performed 2R10 by Snubber 2CCA-16-H3                          F1.10F                                    Snubber Group.
2CCA-16-2" 29-038                                      F-A    VT-3                      8 0 0    Inspection performed 2R10 by Snubber 2CCA-16-H4                          F1.10F                                    Snubber Group.
2CCA-16-2" 29-054                                      B-J    PT(Initial)              9 O O    in addition to the Code exam of thc Pipe To Elbow Socket Weld                  B 9.40                                    weld an augmented volumetric 2CCA-16-2"                                                                            examination was performed 2R10 on the elbow base metal region in response to a plant identified concern. No evidence of thermal cycling induced fatigue degradation was detected.
29-055                                      B-J    PT(Initial)              B O O    in addition to the Code exam of thc Elbow To Pipe Socket Weld                    B 9.40                                    weld an augmented volumetric 2CCA-16-2"                                                                              examination was performed 2R10 on the elbow base metal region in response to a plant identified concern. No evidence of thermal cycling induced fatigue degradation was detected.
29-056                                      B-J    PT(Initial)              8 O O    An augmented volumetric Pipe To Tee Circumferential Weld            B 9.21  UT45 Shear-Axial B O O            examination was performed 2R10 2CCA-16-2"                                          UT45" Shear-Cire        8 O O    in response to a plant identified UT60 Shear-Axial 8 0 0            concern. No evidence of thermal cycling induced fatigue degradation was detected. Code credit also taken for all examinations performed
 
  -            ~~                        -                    ..            .-            -~n, e              7
  +1 ENO12.~IS.
y    .,                  ms -
i
                                            .m,  s gI C,g#r,spons..atiEsen.n.
n w
li
                                                    ,t 3n/I
                                                          .  ,p
                                                            .n,s m,
ec.iMS tm..  ~ i un,  .
mary'
                                                                                      .,.sR2R10'&R7 y m  m  %  m  s-a  u.t.
O,n    g
                                                                                                                    -w.
ge,  N jgg L,~
N        O                      ESAWW~
92rktPiNod AShfE                                O    G T                        ggyz  ~
g ISI Eram No.                                  Code              Nondestructive    R E 11 Eeamination Area Description                Category            Examinations      E O E Component / Piping Line No.                Item No.                Performed      C M R                      Remarks                    '
29-062                                      F-A            VT-3                    9 O O        Inspection performed 2R10 by Snubber 2CCA-16-H21                        F 1.10F                                            Snubber Group.                          j i
2CCA-16-2"                                                                                                                            i 29-064                                    F-A            VT                  0 00        Inspection performed 2R10 by Snubber 2CCA-16-H16                        F1.10F                                              Snubber Group.                          )
2CCA 16-2" 29-068                                    F-A            VT-3                    9 O O        Inspection performed 2R10 by Snubber 2CCA-16-H12                        F1.10F                                              Snubber Group.
2CCA-16-2" 29-069                                    F-A            VT-3                    0 0 9        IRF 7186 evaluated a 2R10 One-Way Restraint 2CCA-16-H13              F 1.10A                                            reported missing snap ring 2CCA-16-2"                                                                                    (keeper) from a sheer pin. This was verified by a field walkdown The evaluation concluded the support was still capable of sening
* its intended design function, however, a snap ring was installed.
33-008                                    RG            UT45* Tangent          9 O O        Examination performed 2R10.
Motor Flywheel- Bore and Keyway            1.14 RC Pump 2P32C 34-008                                    RG            UT45* Tangent          8 O O        Examination performed 2R10.
Motor Flywheel - Bore and Keyway            1.14 RC Pump 2P32D 35-019                                    F-A            VT-3                  9 0 0        Inspection performed 2R10 by Snubber 2CCA-32-H2                        F 1.10F                                            Snubber Group.
2CCA-32 2" 40-026                                    B-F            MT(Initial)          9 0 0        An augmented volumetric Safe End To Nozzle Circumferential Weld    B 5.130 UT32* RLong-Cire 9 O O                    examination was performed 2R10 2CCA-27-2"                                                UT45* RLong-Axial O 9O            in response to a plant identified concern. No evidence of thermal -
cycling induced fatigue degradation was detected. Code credited examinations to be performed 3rd Period.
41-045                                      F-A            VT-3                  O O 9        The inspection performed 2R10 by Snubber 2CCA-26-H2                          F 1.10F                                            the Snubber Group revealed some        j 2CCA-26-2"                                                                                    play in the rear clevis bracket. The, j spherical bearing on the snubber      l extension end paddle was replaced      !
which reduced the play.                l 42-002                                      B-F            PT(Initial)          B O O        Examination performed 2R10.
Nozzle To Flange Circumferential Weld      B 5.40        UT45" RLong-Axial 9 O O Prz Safety Nozzles                                        UT45* RLong-Cire 9 O O 42-003                                      B-F            PT(Initial)          9 OO          Examination performed 2R10.
l Nozzle To Flange Circumferential Weld      B 5 40        UT45 RLong-Axial 9 O O                                                i Prz Safety Nozzles                                        UT45* RLong-Cire 9 0 0 l
 
i 3..u. w n . -r ~ . s. :- t
                                    -?
m-      _ ;- "ygQy
                                                              .v...Q p[.- c-  :
_._.,,y  s        ,____2,_,    ~^~^w  % r s:n ~ q  ye. mqgy:g      y _.
ed n%NO-2tlS'I                                                                        i ,4 _p
* q sg,          g - me-                C,Q?fg___g___,Jm.ponent:Exami wnumv ~        ~>gw+                            - attn
                                                                                              .n /In,_Sp=ec.t n.. W2R1.m  -
tn Sumw w _.m,        aryra n,muaQQ0ENo am        sOu N            O l
ASME                                    O        G T                              pgg~ym{w
                                                                                                                                                ~~    '
ISI Eram No.                                                Code              Nondestructive      R        E H Examination Area Description                            Category                Examinations      E O E Component / Piping Line No.                            Item No.                  Performed        C M R                              Remarks 42-011                                                  B-G-2              VT-1                  8 O O              Inspection performed 2R10.
Flange Bolting                                          B 7.50 Prz Safety Nozzles 42-012                                                  B-G-2              VT-1                  O O O              Inspection performed 2R10.
Flange Bolting                                        B 7.50 Prz Safety Nozzles 52-013                                                C-F-1              PT(Initial)            9 O O              Examination performed Elbow To Pipe Circumferential Weld                    -
UT45' Shear-Axial O 9 O                    Non-Outage.
2GCB-5-14"                                                                UT45' Shear-Circ      0 0 0 52-013AB                                              C-F-1              PT(Initial)            B CD                Examination performed l
Elbow Longitudinal Welds                              -
UT45' Shear-Axia! 9 O O                    Non-Outage.
i 2GCB-5-14"                                                                UT45* Shear-Circ      2 O O i  52-014                                                C-F-1              PT(Initial)            0 0 0              Examination performed f
Pipe To Elbow Circumferential Weld                    ---
UT45* Shear-Axial B OO                    Non-Outage.
2GCB-5 14"                                                                UT45* Shear-Circ      9 0 O l  52-015AB                                              C-F-1              PT(Initial)            B OO                Examination performed l  Elbow Longitudinal Welds                              --
UT45* Shear-Axial E OO                    Non-Outage.
2GCB-5 14'                                                                UT45' Shear-Cire      E O O 52-031 AB                                              C F-1              PT(Initial)            8 O O              Examination performed Elbow Longitudinal Welds                              -
UT60* Shear-Axial O O O                    Non-Outage.
2GCB-2-12"                                                                UT60* Shear-Cire      @OO l  52-032                                                C-F 1              PT(Initial)            8 0 0              Examination performed l  Elbow To Pipe Circumferential Weld                    ---
UT60* Shear Axial O 9 O                    Non-Outage.
2GCB 2-12"                                                                UT60* Shear-Cire      9 0 0 52-037                                                F-A                VT-3                  8 OO                Inspection performed Non-Outage.
Multi-Directional Restraint 2GCB-5-H10                F 1.20B 2GCB-5-14" f  52-039                                                F-A                VT-3                  9 O O              Inspection performed Non-Outage.
One-Way Restraint 2GCB-5-H12                            F 1.20A 2GCB-5 14" 54-034                                                  F-A                VT-3                  9 O O              Inspection performed Non-Outage.
l  Variable Spring 2GCB-3 H13                              F 1.20C i  2GCB-3-12" l  54-037                                                  F-A                VT-3                  9 O O              Inspection performed Non-Outage.
;  Anchor 2GCB-3-H18                                      F1.20E j  2GCB-3-12" 56-003                                                  C-F-1              PT(Initial)            9 O O              Examination performed Pipe To Elbow Circumferential Weld                      -
UT45' Shear-Axial 8 00                    Non-Outage.
I l
2GCB-8-14"                                                                UT45* Shear-Cite      9 0 O 56-004AB                                                C-F-1              PT(Initial)            9 O O              Examination performed i  Elbow Longitudinal Welds                                -
UT45* Shear-Axial 9 0 0                    Non-Outage.
2GCB-8-14"                                                                UT45* Shear-Cire      B D 0 57-025                                                  F-A                VT-3                  8 0 0              Inspection performed 2Rio by Snubber 2GCB-3-H22                                      F120F                                                        Snubber Group.
2GCB-3-12"
 
: r.                      s        -
                                                .;. :. ~ n. w. :w. y.,,..
                                                                          -Q-    ~9                      3. .
                                                                                                                          ..n
                                                                                                                          -    . , u .a , y .x .,. < . . . . . . ,
c:Nq.gs%."NO42 A :.x :. n.c w Qanwww!1S1            C6:? iip O%' %.
6de}pi.YW                                            1 I. . v q:Sdama:q u:.yafEiainEatiSi/          r n. ww Ins';psd6g          n.yr m e2_ m  Rid %,m(N.6hiOWisjE$$m;p                            i w                  wma em              '-
a    > w8 c                                    .n:>  a                          e wn as                                j N          O                            NEMN ASME                                            O  G      T ISIExam No.                                          Code                Nondestructive          R  E H Ex:mination Area Description                      Category                Examinations            E  O E Component / Piping Line No.                      Item No.                  Performed            C M R                        Remarks 59-038                                            F-A                    VT-3                      8 O O        Inspection performed Non-Outage.
Variable Spring 2GCB-16-H2O                      F 1.20C                                                                                                            l 2GCB-16-10" l
59-039                                          F-A                    VT-3                      9 O O        Inspection performed Nonoutage.
One-Way Restraint 2GCB 16-H21                    F 1.20A                                                                                                            q 2GCB 16-10" 59-040                                          F-A                    VT-3                      8 OO          Inspection performed Non-Outage.
One-Way Restraint 2GCB-16-H19                    F 1.20A 2GCB-16-10" 59 049W                                          C-E-1                  PT(Initial)              E OO          A surface (PT) examination was Integrally Welded Attachment 2GCB 16-H2          C 2.5                                                          performed Non-Outage in response 2GCB-16-12"                                                                                                    to ist Interval Relief Request C-E-1/C2.5. The interfering pipe clamp was temporarily removed from an adjacent support to enable a complete surface exam of this stanchion attachment weld.
61 042                                          F-A                    VT 3                      9.O O        Inspection performed Non-Outage.
l  Multi-Directional Restraint 2GCB-7-H7            F1.20B 2GCB-7-6" 61-044                                          F-A                    VT-3                      9 O O        Inspection performed Non-Outage.
One-Way Restraint 2GCB 7-H21                    F 1.20A 2GCB-7-6" f  62-002                                          C-F-2                  MT(Initial)              2 OO          Examination performed 2R10.
!  Pipe To Flued Head Penetration Circumferential C 5.51                  UT45' Shear-Axial O EO Weld                                                                    UT45' Shear-Cire          9 OO 2DBB-1-24" 62-009W                                          C-C                  MT(2P93 Outage)          O O E        Linear surface (PT) indications Integrally Welded Attachment 2DBB-1-HS            C 3.20                MT(2R10 Outage)          O OE          recorded during both 2P93 and 2DBB-1-24"                                                                                                      2R10 exams. These indications                      1 originate from the metal-to-metal                  )
l                                                                                                                  interfaces of the pipe support (i.e.,
plate-to-pipe and plate-to-plate) l                                                                                                                  and are a geometric condition (CR 2-92-0399-5).                                i 63-006                                          C-F-2                MT(Initial)              B OO          Examination performed 2R10.                      l ,
Sweepolet To Flange Circumferential Weld        C 5.51                UT45' Shear-Axial E OO                                                                      l 2 EBB-1-10"                                                            UT70 Shear-Axial 8 O O 63-013                                          C-F-2                UT60* Shear-Axial O E O                An augmented volumetric Pipe To Pipe Circumferential Weld                C 5.51                                                        examination was performed 2R10 2 EBB- t-38"                                                                                                  in response to Branch Technical Position MEB 3 1. No evidence of.
degradation was detected.                        l 63-014                                          C-F-2                UT60* Shear-Axial B D O                  An augmented volumetric                          j Pipe To Elbow Circumferential Weld              C 5.51                                                        examination was performed 2R10 2 EBB-1-38"                                                                                                    in response to Branch Technical Position MEB 3-1. No evidence of degradation was detected.
 
              -^
              ,m% ,rfh- D[ .h* m,          Y        ,  ,( ,Y 4-  - Er      ' ' .+ ,-                    -,          s t '=+                ,
r  .g +
                                                                                                                                                                        /'
sashme%vwAs JANO""'"4'D          2*..
                                    ?''l'//
SI ^' .yf' 'dsnpsssst    Fasnii%iin'r'/I'n, specti6n"eSu' mniaiy'              ?' 2" R' cr i -mm n' 'g/ab' I+10'a,-  f' r ~d' m%
u, si'N sg"MMENnis Q' '',."
en        w-''"                ++  1
                                                                                                      - -    - ~
N            O                        NN
* ASME                                    O    G        T MidPirlad)          i
                                                                                                                                                              -9g ; -
ISI Eram No.                                                      Code            Nondestructive        R    E H i
Ex mination Area Description                                  Category            Examinations        E    O E l        Component / Piping Line No.                                    Item No.              Performed          C M R                            Remarks                  i t
63-015                                                        C-F-2            UT60" Shear-Axial O O B                    An augmented volumetric Elbow To Pipe Circumferential Weld                            C 5.51                                                      examination was performed 2R10 2 EBB 1-38"                                                                                                              in response to Branch Technical Position hEB 3-1. One Code-acceptable slag indication          j recorded of an acceptable size per Table IWB-3514-1.
63-015AB                                                      C-F-2            UT60* Shear-Axial O 9 O                    An augmented volumetric Elbow Longitudinal Welds                                      C 5.52                                                      examination was performed 2R10 2 EBB-1-38"                                                                                                              in response to Branch Technical          )
Position hEB 3-1. No esidence of degradation was detected.
l          63-016                                                      C-F-2            UT60* Shear-Axial B D D                    An augmented volumetric                  I Pipe To Reducer Circumferential Weld                        C 5.51                                                      examination was performed 2R10 l
l          2 EBB-1-38"                                                                                                              in response to Branch Technical Position hEB 3-1. No evidence of degradation was detected.
l          63-017                                                        C-F-2            UT60* Shear-Axial 9 0 0                  An augmented volumetric Reducer To Valve Circumferential Weld                        C 5.51                                                    examination was performed 2R10 2 EBB-1-36"                                                                                                              in response to Branch Technical l
Position hEB 3-1. No evidence of f                                                                                                                                  degradation was detected.
l          63-017A                                                      C-F-2            UT60 Shear-Axial B D D                    An augmented volumetric l          Valve To Reducer Circumferential Weld                        n/a                                                        examination was performed 2R10 l          2EBD-1-36"                                                                                                                in response to Branch Technical Position hEB 3-1. No evidence of degradation was detected.
63-017C                                                      C-F-2            UT45* Shear-Cire        9 O O              An augmented volumetric Pipe to Pipe Circumferential Weld                            n/a              UT60 Shear-Axial O E O                    examination was performed 2R10 2EBD-1-38"                                                                    UT60* Shear-Circ        9 O O              in response to Branch Technical Position hEB 3-1. No evidence of        I degradation was detected.
64-002                                                        C-F-2            MT(Initial)            8 O O              Examination performed 2R10.              ,
Pipe To Elbow Circumferential Weld                            C 5.51          UT45' Shear Axial B O O 2DBB-2-24"                                                                    UT45' Shear-Cire        9 O O 64-003                                                        C-F-2            MT(Initial)            9 O O              Examination performed 2R10.
Elbow To Pipe Circumferential Weld                            C 5.51            UT45 Shear-Axial B O O 2DBB-2-24"                                                                    UT45" Shear-Cire      8 O O                                                      l 4
l 64-004                                                        C-F-2            MT(Initial)            0 0 0              Examination performed 2R10.
Pipe To Elbow Circumferential Weld                            C 5.51          UT45 Shear-Axial 8 O O                                                            .
2DBB-2-24"                                                                    UT45* Shear-Cire      Z O O                                                      I 65-014                                                        C-F-2            MT(Initial)            9 O O              Examination performed 2Rio.
Pipe To Swecpolet Branch Connection Weld                      C 5.81 l
2 EBB-2-38" 65-019                                                        C-F-2            UT60 Shear-Axial 8 0 0                    An augmented volumetric                l Reducer To Valve Circumferential Weld                        C 5.51                                                      examination was performed 2R10 2 EBB-2-36"                                                                                                              in response to Branch Technical Position MEB 3-1. No evidence of !
degradation was detected.
1 ._- . _ _ _ _ _ - . . _ _ - _ _ - _ _ _-.
 
  ,a    $$NdMM w  e ce s or r      SpssEEEiiisN' x  r ~ %.c ms c wmU9friispesut(Ssi.nis,afp_M,Ri.dM,
                                                            .w34      .
s  m. w  3 .~        w N$$,6Mgjgggg
                                                                                                      .n MMi N      O ASME                      O  G  T                      *nggg{g ISI Eram No.                                    Code    Nondestructive  R  E H Examination Area Description                  Category  Examinations    E O E
; Ccmponent/ Piping Line No.                    Item No. Performed      C M R                    Remarks 6>019A                                        C-F-2    UT60 Shear-Axial 9 0 0          An augmented volumetric
, Valve To Reducer Circumferential Weld        n/a                                      examination was performed 2R10      l 2EBD-2 36"                                                                            in response to Branch Technical      i I
Position MEB 3-1. No evidence of degradation was detected.            l 65-019C                                      C-F-2    UT45 Shear-Cire    9 O O        An augmented volumetric Pipe to Pipe Circumferential Weld            n/a      UT60* Shear-Axial O E O        examination was performed 2R10 2EBD 2-38"                                            UT60* Shear-Cire  B O O        w response to Branch Technical Position MEB 3-1. No esidence of degradation was detected.
65-021                                      C-F-2    MT(Initial)        9 OO        Examination performed 2R10.
Valve To Pipe Circumferential Weld          C 5.51  LTr45* Shear-Axial 0 00 2 EBB-9-10"                                          UT45* Shear-Cire  9 O O UT60 Shear-Axial O 9 O 65-036W                                      C-C      MT(Initial)        B O O        Examination performed 2R10.
Integrally Welded Attachment 2 EBB-2-H2      C 3.20 2 EBB-2-38" 65-038                                      F-A      VT 3              0 0 0        Inspection performed 2R10 by Snubber 2 EBB 2-H5                          F 1.20F                                  Snubber Group.
2 EBB-2-38" 65-038W                                      C-C      MT(Initial)        9 O O        Examination performed 2R10.
Integrally Welded Attachment 2 EBB-2-H5      C 3.20 2 EBB-2-38" 66-017W                                      C-C      PT(Initial)        8 O O        Examination performed 2R10.
Integrally Welded Attachment 2CCB-5-H1      C 3.20 2CCB-5-6" 72-046W                                      D-B    VT-3              2 00        Inspection performed Non-Outage Integrally Welded Attachment 2HCB-50-H6      D 2.20 2HBC-50-18" 72-100W                                      D-B    VT-3              8 OO        Inspection performed Non-Outage.
I Integrally Welded Attachment 2HBC 50-H10      D 2.20 2HBC-50-18"                                                                                                              l 72-102W                                      D-B    VT-3              9 O O        Inspection performed Non-Outage. l Integrally Welded Attachment 2HBC-83-H1      D 2.20                                                                      1 2HBC-83-30"                                                                                                                l 72-108                                        F-A    VT-3              8 O O        Inspection performed Non-Outage.
One-Way Restraint 2HBC-83-H3                  F 1.30A 2HBC-83-30" 72-108W                                      D-B    VT-3              8 O O        Inspection performed Non-Outage.
Integrally Welded Attachment 2HBC-83-H3      D 2.20 2HBC-83-30" 72-109                                      F-A    VT-3              9 O O        Inspection performed Non-Outage.
Multi-Directional Restraint 2HBC-83-H6      F 1.30B I
2HBC-83-30" 72-109W                                      D-B    VT-3              8 O O        Inspection performed Non-Outage. . l Integrally Welded Attachment 2HBC-83-H6      D 2.20 2HBC-83-30"
 
4%n  hkhh,hkhINIhlhbH
                            - ~ m r evisu- -hNkinlibbftt/InSpdClion
                                                        <-    ~          -  - - - '
Sdbik,IffYN sim x -  ..mam hhNfbktA[$%;w r~w        r w.
N          O                        :            ;
AShfE                            O    G    T                          yyyyy ISIEram No.                                      Code    Nondestructive        R    E H Examination Area Description                  Category  Examinations            E  O    E Component / Piping Line No.                    Item No. Performed            C M R                        Remarks 72-110                                        FA      VF-3                    9 O O          Inspection performed Non-Outage.
Multi-Directional Restraint 2HBC-83-H8        F 1.30B                                                                                ,
2HBC-83-30"                                                                                                                          I 72-110W                                        D-B      VT-3                    9 OO            Inspection performed Non-Outage.
Integrally Welded Attachment 2HBC-83-H8        D 2.20 2HBC-83-30" 72-111                                        F-A      VT-3                    9 O O          Inspection performed Non&tage.        I Anchor 2HBC-83-H7                            F1.30E 2HBC-83-30" 72-111W                                      D-B      VT-3                    9 O O          Inspection performed Non-Outage.
Integrally Welded Attachment 2HBC-83-H7      D 2.20 2HBC-83-30" 72-112                                        F-A      VT-3                    9 O O          Inspection performed Non-Outage.
Multi-Directional Restraint 2HBC-83-H5        F1.30B 2HBC-83-30" 72-Il2W                                      D-B      VT-3                    9 O O          Inspection performed Non&tage.
Integrally Welded Attachment 2HBC-83-H5      D 2.20 2FEC-83-30" 72-115W                                      D-B      VT-3                    9 O O          Inspectioti performed 2R10.          )
Integrally Welded Attachment 2HBC-103-H29    D 2A0 2HBC-103-8" 72 132                                        F-A      VF-3                    9 O O          Inspection performed 2R10.
Variable Spring 2HBC-103-H5                  F 1,30C 2FGC-103-12" 72132W                                        D-B    VF-3                    9 O O          Inspection performed 2R10.
Integrally Welded Attachment 2HBC-103-H5      D 2 40 2HBC-103-12" 72-136W                                        D-B    VF-3                    9 O O          Inspection performed 2RIO.
Integrally Welded Attachment 2HBC 103-H18      D 2.30 2HBC-103-12" 72-137                                        F-A    VT-3                    9 O O          Inspection performed 2R10 by Snubber 2HBC-103-H2O                          F1.30F                                          Snubber Group.
2HBC-103 12" 72-138                                        F-A    VF-3                      9 O O          Inspection performed 2R10 by Snubber 2HBC-103-H17                          F1.30F                                          Snubber Group.
2HBC-103-12" 72-139                                        FA      VT-3                      9 O O          Inspection performed 2R10.
One Way Restraint 2HBC-103-H16                F 1.30A 2HBC-103-12" 72-139W                                      D-B    VF-3                      8 0 0          Inspection performed 2R10.
Integrally Welded Attachment 2HBC-103-H16    D 2.20 2 HBC-103-12" 72-14i                                        F-A    VF-3                      0 0 9          IRF 7187 evaluated 2R10 reported One-Way Restraint 2HBC-103-H19                F 1.30A                                          conditions of baseplate gap & loose 2HBC-103-12"                                                                                  anchor bolts, spalled concrete, and pipe to support gaps. These v,cre all verified by a field walkdown.
The evaluation concluded tlat these conditions are acceptable.
u___
 
H
, - +,.+ e - -          ~w w                        . . . < - - / . .    ~ ~  v    v - men =,+.~                          -
nnu.4.pn EE
                                      -~    x.,
M.Os%              .
m y 3. y,N. Oj2 IS.I.C.7.w.r,ji,si.i.s.. nt:E. .sassin.a..ti.th/Inspbet..i6n
                                                        ~
3  ,m        -
a        0 .m.y.;itK.c 2 Sum.      w yys T
                                                                                                                  .R.1e%N2      SO N      O ASME                          O  G  T                        h v gy{L ISI Exam No.                                        Code        Nondestructive R  E H Examination Area Description                    Category          Examinations  E  O  E Component / Piping Line No.                    Item No.          Performed    C M R                      Remarks                !
1 72-141W                                        D-B          VT-3              0 0 0        Inspection performed 2R10.
Integrally Welded Attachment 2HBC-103-H19      D 2.20 2HBC-103-12" 72-144 A                                        F-A          VF-3              8 OO        Inspection performed 2R10 by Snubber 2HBC-105-H27                            F1.30F                                      Snubber Group.
2HBC-105-8" 72-159                                          F-A          VT3              9 OO        Inspection performed 2R10 by Snubber 2HBC-105-H14                          F1.30F                                      Snubber Group.
2HBC-105-12" 73-038                                        FA          VF-3              8 OO        Inspection performed Non-Outage.
Anchor 2HBC-43-H3                              F 1.30E 2HBC-43-16" 73-038W                                        DB          VF-3              9 OO        Inspection performed Non-Outage.
Integrally Welded Attachment 2HBC-43-H3        D 2.20 2HBC-43-16" 73-048W                                        D-B        VF-3              9 OO        Inspection performed 2R10.
Integrally Welded Attachment 2HBC-76-H9        D 2.20 2HBC-76-8" 73-056W                                        D-B        VF3              E O O        Inspection performed Non-Outage.
Integrally Welded Attachment 2HBC-76-H13        D 2.20 2HBC-76-8" 73-093B                                        F-A          VT-3            8 OO          Inspection performed 2R10 by Snubber 2HBC-104-H18                          F1.30F                                      Snubber Group.
2HBC-104-12" 73-103                                        F-A          VT-3            9 00          Inspection performed Non-Outage.
Multi-Directional Restraint 2HBC-76-H11        F1.30B 2HBC-76-8" 73-103W                                        D-B          VF-3            9 O O        Inspection performed Non-Outage.
Integrally Welded Attachment 2HBC-76-H11      D 2.20 2HBC-76-8" 73-104                                        F-A          VF3              9 OO          Inspection performed Non-Outage.
Multi-Directional Restraint 2HBC-76-H12        F1.30B 2HBC-76-8" 73-110W                                        D-B        VF-3              9 OO          Inspection performed Non-Outage.
Integrally Welded Attachment 2HBC-51-H6        D 2.20 2HBC-51-18" 73-111                                          F-A        Vr-3              O O9          IRF 7135 evaluated a Non-Outage One-Way Restraint 2HBC-76-H14                  F 1.30A                                    reported condition of a bent beam 2HBC-76-8"                                                                                  attachment. This was verified by a field walkdown. The evaluation concluded that the slightly bent beam attachment will still perform its design function and the condition is acceptable.
73-I l l W                                    D-B          VT-3            8 00          Inspection performed Non-Outage integrally Welded Attachment 2HBC-76-H14      D 2 20 2HBC-76-8" m
 
p
    .)2.. $ b,. h-  L".'d' [t . p.N - . . ..''./  l _  _.t ."#
(        .C ,q..I'        f. .3,  - -.j g.d  , *.E'  N  % '
                                                                                                                                                % g[ ffj%"'    _
g /
l m TAN''?
w,gw        s    - O12ilSI'C, mw - 4 ?mp>onent:E')xaminid_N.oh'"/Inspecti:n'[Su'
                                                  .... . .mww      a -- , ,        >+    n.      -
:;n. - mm,arywd.
                                                                                                                ,u  . - - - 1.2'"AR'%,f.
man          en wa
                                                                                                                                          #,msa-Os''m_"tage
                                                                                                                                      '0 &'luh                ,,w.,,n.xh i                                                                                                            y            o                                MMMM Y2ndPeribbl l                                                                    ASME                                    O    G      T                              9ggg -
ISI Exam No,                                                          Code          Nondestruaive          R    E H Eximination Area Description                                      Category        Examinations            E O E l
I Component / Piping Line No.                                        Item No.          Performed              C M R                              Remarks l
75-041                                                            F-A            W -3                      9 0 0              Inspection performed 2Rio by Snubber 2GCB 10-H5                                                F1.20F                                                      Snubber Group.
2GCB 10-12" 76-046                                                            F-A            W -3                      9 O O              Inspection performed 2R10 by Snubber 2GCB-Il-H5                                                F1.20F                                                      Snubber Group.
2GCB-11 12"
\
76-047                                                            FA            W3                        9 0 0            Inspection performed Non-Outage.
Variable Spring 2GCB-11-H3                                        F 1.20C 2GCB-11-12" 78-06i                                                            F-A            VT-3                      9 O O            Inspection perfortned 2R10 by Snubber 2HCB-15-H15                                                F1.20F                                                      Snubber Group.
i  2HCB-15-14" 80-545                                                            FA            W-3                        8 O O            Inspection performed Non-Outage.
Variable Spring 2DCB-501-(Detail B)                                F 1.20C 2DCB-501-2" 80 548                                                            FA            VT-3                        9 O O            Inspection performed Non-Outage.
One-Way Restraint 2DCB-501-(Detail O)                              F 1.20A 2DCB-501-2" 80-556                                                            F-A          Vr-3                        8 0 0            Inspection performed Non-Outage.
l Multi-Directional Restraint                                      F 1.20B l  2DCB-500-PS-3/PG-32 2DCB-500-2" l
l  80-557                                                            F-A          VT-3                        9 O O            Inspection performed Non-Outage.
l  Multi-Directional Restraint                                      F 1.20B l
2DCB-500-PS-3/PG-Il 2DCB-500-2" l  80-558                                                            F-A          VT-3                        9 OO              Inspection performed Non-Oatage.
Multi-Directional Restraint                                      F 1.20B 2DCB-500-PS-5/PG-11 l  2DCB-500-2"
!  80-582                                                            F-A          VT-3                        9 0 0            Inspection performed Non-Outage.
Variable Spring 2DCB l-H2                                        F 1.20C 2DCB 1-4"                                                                                                                                                            l 80-599                                                            FA          VT 3                        9 OO              Inspection performed Non-Outage.
:    One-Way Restraint 2DCB 3-H27                                      F 1.20A i    2DCB-3-3" 81-223                                                            F-A          VT-3                        9 0 0            Inspection performed Non-Outage.
Variable Spring 2CCB 12-H007                                    F 1.20C 2CCB-12-4" 81-237                                                          FA            Vr-3                        8 0 O              Inspection performed Non-Outage.
Multi-Directior.al Restraint 2CCB-70-H2O                        F 1.20B 2CCB-70-3" 81 238                                                          F-A          VT 3                        9 00              Inspection performed Non-Outage.
Multi-Directional Restraint 2CCB-70-H21                          F 1.20B 2CCB-70-3" 85-210W                                                          D-B          VT-3                        9 O O              Inspection performed Non-Outage.
Integrally Welded Attachment 2DBC-2-H10                          D 2.20 2DBC-2-4"
 
e      . Wy. ' -        .<w                  a n %6.w.      W    jg
      -s.w:a. : %%w    -g            4 p e - sw..- . e am . ... -Me.-                      3
                                                                                                        .ve -i l%NOf2 I""Sig>:dp:::. ih    pussatLEiapiniitioit/In;WR,itisj    spe                  aity"R'10ld''rn-Wu.$Out S' unijn..e                              g Q [$
AShfE N
O    G O
T ffflhh; Qa  c ISI Exam No.                                            Code            Nondenructive    R    E 11 Examination Area Description                          Category          Examinations      E    O    E ComponenuPiping Line No.                              Item No.            Performed      C Af R                        Remarks 85-211W                                                D-B            VT-3                9 O O          Inspection performed Non-Outage.
Integrally Welded Attachment 2DBC-2-H11              D 2.20 2DBC-2-4" 85-212W                                              D-B            VT-3                9 O O          Inspection performed Nonoutage.
Integrally Welded Attachment 2DBC-2-H12              D 2.20 2DBC-2-4" 85-215                                                F-A            VT-3                0 0 0          Inspection performed Non4utage.
Multi-Directional Restraint 2DBC-2-H15                F 1.30B 2DBC-24" 85-215W                                              D-B          VT-3                8 O O        inspection performed Non-Outage.
Integrally Welded Attachment 2DBC-2-H15              D 2.20 2DBC-2-4" 85-217                                                F-A          VT-3                9 O O          Inspection performed Non-Outage.
One-Way Restraint 2DBC-2-H17                          F 1.30A 2DBC 24" 85-217W                                              D-B          VT-3                8 O O          Inspection performed Nonautage.
Integrally Welded Attachment 2DBC-2-H17              D 2.20 2DBC-24" 85-218                                                F-A          VF-3                8 O O          Inspection performed Nonautage.
Multi-Directional Restraint 2DBC-2-H18                F 1.30B 2DBC-24" 85-218W                                              D-B          VT-3                8 O O          Inspection performed Nonoutage.
Integrally Welded Attachment 2DBC-2-H18              D 2.20 2DBC-2-4" 85-220                                              F-A          VT-3                9 O O          Inspection performed Non Outage.
One-Way Restraint 2DBC-2-H20                        F 1.30A 2DBC-2-4" 85-221W                                              D-B          VT-3                9 O O          Inspection performed Nonoutage.
Integrally Welded Attachment 2DBC-2-H21              D 2.20 2 DBC-2-4" 85 703                                                F-A          VT-3                E O O          Inspection performed Non-Outage.
Multi-Directional Restraint 2DBC-7-PG-11              F1.30B 2DBC 7-2" 88-001                                              F-A          VT-3                  9 0 0          Inspection performed Non-Outage.
Pump Support (s)                                    F 1.40 HPSI Pump 2P89A 91-103                                              F-A          VT-3                  O O 9          1RF 7107 evaluated a Non-Outage One-Way Restraint 2GCB-9-H3                          F 1.20A                                            reported condition of a ~ 1/16" gap, 2GCB-9-8"                                                                                              between the pipe and hanger. This was verified by a field walkdown The evaluation concluded that some of the loads will be applied to other supports and the condition acceptable.
91-108                                              F-A            VT-3                8 0 0          Inspection performed Non-Outage i Variable Spring 2GCB-9-H8                            F 1.20C l
2GCB-9-8" k
 
gg_ _ _._.smas ~sema                            m.    .,  .m
                                                                                            -m-wg*_
M,mANO42:ISI'          Component!E+xamiT~ahy/  on Ins
                                              *um w e . .e
_pe._
c - - ~tion Su.= ....o. ...smmarygan    ni <-2R10 &N'3,d%s 1.#e w. %sa... .--                m at a.wwwwam wezue ww truc N            O                        ShL 9*%
ASME                          O    G T                              US" S ISL Eram No.                                  Code    Nondestructive    R    E H Examination Area Description              Category    Examinations      E    O E Component / Piping Line No.                Item No.      Performed        C M R                          I:emarks 91-111                                    F-A      VF-3                0 09              1RF 7108 evaluated a Non Outage One-Way Restraint 2GCB-9-H11              F 1.20A                                          reported condition of a sliding 2GCB-9-8"                                                                                  plate that is misaligned by 1%*.
The evaluation concluded that this condition is acceptable in the as-found condition.
91-113                                    FA        Vr-3                9 00              Inspection performed Non-Outage.
Anchor 2GCB-9-H13                        F 1.20E 2GCB-9 8" 93-012                                    F-A      Vr3                  9 OO              Inspection performed Non-Outage.
One-Way Restraint 2HCB-23-H2              F 1.20A 2HCB 23-6" 93-019                                    FA        VF-3                9 OO              Inspection performed 2Rio.
Multi-Directional Restraint 2HCB-23-H9    F 1.20B 2HCB-23-6" 94-036W                                  D-B      VF-3                9 OO              Inspection performed Non-Outage.
Integrally Welded Attachment 2HCC-282 H36 D 2.20 2HCC-282-12" 94-037 F-A      VT-3                9 OO              Inspection performed Non-Outage' Multi-Directional Restraint 2HCC-282-H37  F1.30B 2HCC-282-12" 94 038                                    p.A      Vr-3                9 OO              Inspection performed Non-Outage' Multi-Directional Restraint 2HCC-282-H38  F 1.30B 2HCC-282-12" i
l
 
Attachment to 2CAN079403 i
i FORMS NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS l
l l
1 I
 
l l
Attachment to 2CAN079403
                                                            -ABSTRACT l
Repair and replacements were conducted during the tenth operating cycle concluding with the 2R10 refueling outage in accordance with the ASME Code, Section XI,1986 Edition with no Addenda.
Arkwright Mutual Insurance Company (Factory Mutua; Systems) served as the Authorized Inspection Agency as defmed in ASME Section XI, IWA-2120, reviewing applicable pre:saiures, witnessing examinations and checking for general Code compliance as specified in    .
IWA-2110 of the applicable edition and addenda of the Code.                                      ;
Refueling Outage 2R10 is the first outage of the second period of the second 10-year interval.
This report covers repair / replacements performed between October 20,1992 and April 24, .
1994.
Also included in this report are six NIS-2. forms that were not included in the 2R9 ISI Outage Summary Report dated January 18,1993 (2CAN019302),
l I-I
                                                            . _ . .              .,          - - , .              e
 
Attachment to J
2CAN079403 ~
FORM NIS-2 OWNER'S REPORT FOR REPAII, S OR REPLACEMENTS CLASS-1 J.0. NUMBER    DESCRIPTION          COMPONENT I.D.-      ACTIVITY '          ~
1 00858368        6" Globe Valve      2PSV-4633            Repaired & Part .. I
                                                              - Replacement 00859762        6" Globe Valve        2PSV-4634            Part Replacement 00872533        6" Check Valve '    2SI-14A              Part Replacement '
00873971        3" Globe Valve        2CV-4651            Part Replacement -
00874082        6" Globe Valve      .2PSV-4633            Part Replacement 6" Globe Valve        2PSV-4634            Part ReplacementJ 00874083      L6" Globe Valve    ' 2PSV-4633            Part Replacement 00887843        6" Globe Valve      2PSV-4634 '          Replacement 00887846        6" Globe Valve      2PSV-4633            Part Replacement '
00889664        Steam Generator      2E-24A            : Part Replacement 00890731        12" Check Valve -    2SI-15D              Part Replacement 00898754      ' 3" Check Valve      2SI-13A              Replacement          -
00903058        12" Check Valve    2SI-15A -            Part Replacement -
00905586'        Component Support 2CCA-15-H49 '        . Repaired 00905669        1" Globe Valve      2SV-5001-1        : Repaired 00906016        12" Check Valve      2SI-15C    .        Part Replacement i      00907826        Snubber-          " 2CCA-13-H4        . Replacement .
I-                      Snubber          . 2CCA-14-H2.-          Replacement Snubber              2CCA-15-H9          Replacement Snubber              2CCA-15-H24'        Replacement        'i Snubber              2CCA-15-H261        Replacement-        t Snubber              2CCA-15-H27      . Replacement .        ?
Snubber              2CCA-15-H29          Replacement Snubber              2CCA-15-H30          Replacement-        t Snubber -            2CCA-16-H1          Replacementi      -,
1 Snubber              2CCA-16-H4 -        Replacement-Snubber              2CCA-16-H3.          Replacement Snubber              2 EBB-7-H2        ' Replacement .
Snubber              2GCB-10-H5        - Replacement Snubber              2HS-SGB-E2          Replacement          :
Snubber              2CCA-14-H5          Replacement'.        >
Snubber              2CCA-15-H31          Replacement Snubber              2CCA-15-H34          Replacement Snubber              2CCA-15-H36          Replacement Snubber              2CCA-15-H39          Replacement
;                      Snubber              2CCA-15-H41          Replacement          <
l                      Snubber              2CCA-15-H44A '    . Replacement Snubber              2CCA-15-H44B        Replacement Snubber              2CCA-15-H45        - Replacement Snubber              2CCA-15-H50          Replacement Snubber              2CCA-15-H53          Replacement Snubber              2CCA-15-H56          Replacement Snubber              2CCA-15-H60          Replacement Snubber              2CCA-16-H21        -Replacement
 
Attachment to 1
2CAN079403 1
J.0. NUMBER  DESCRIPTION        COMPONENT I.D.      ACTIVITY Snubber            2CCA-16-H12        Replacement Snubber            2CCA-16-H16 '      Replacement    !
00910284      Com ponent Support 2CCA-15-H30        Repaired      !
00910820      1" G obe Valve    2SV-4636-2          Repaired 00910821      1" Globe Valve    2SV-4636-1          Repaired 00908358      6" Check Valve    2SI-14A            Replacement-  t 00911983      1" Globe Valve    2SV-4668-2          Replacement    '
00912145      Snubber            2CCA-15-H44A & B    Repaired Snubber            2CCA-15-H53        Repaired Snubber            2CCA-15-H60        Repaired      ,
Snubber            2CCA-16-H12        Repaired 1
l l
i l
l l
l l
j l
 
i Attachment to j                                                2CAN079403 l
l FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT S CLASS-2 l
J.0 NUMBER      DESCRIPTION            COMPONENT I.D. ACTIVITY        l 1
!                                                00813666        4" Gate Valve        2CV-1066-1    Part Replacement l                                                00854640        1" Gate Valve        2SI-1036      Repaired l                                                00857863        1" Gate Valve        2MS-55        Replacement      ,
j                                                00866837        2" Globe Valve        2CV-5016-2    Part Replacement 00875223        3/4" Globe Valve      2SGS-21B      Repaired 00880722        2" Globe Valve        2CV-5036-2    Part Replacement 00884165        1" Gate Valve        2SI-1640      Replacement
,                                                                1" Gate Valve        2Sb1041        Replacement i                                                00886957        3/4" Globe Valve      2CVC-1096      Replacement 00888288        3/4" Globe Valve      2CVC-1099      Repaired 00889340        1" Globe Valve        2SV-5046      Repaired j                                                00889341        1" Globe Valve        2SV-5004      Repaired 00892261        Component Support 2HCB-33-H8        Repaired 00892262        Component Support 2HCB-33-H6        Repaired 00892313        1" Globe Valve        2SI-50        Repaired 00893120        1" Globe Valve        2SV-0205      Repaired 00893805        1" Gate Valve        2SI-1036      Replacement 00893882        1" Gate Valve        2BS-1070B      Replacement 00894157        8" Globe Valve        2PSV-1003      Part Replacement 00894157        8" Globe Valve        2PSV-1003      Replacement 00894219        1" Gate Valve        2CV-2428      Repaired l                                                00898455        2" Gate Valve        2CV-1090-2    Repaired 00900999        8" Globe Valve        2PSV-1055      Part Replacement 00904161        Component Support 2CCB-70-H6        Repaired 00905763        2" Check Valve        2CVC-78        Repaired 00905763        2" Check Valve        2CVC-78        Replacement 00907954        Component Support 2GCB-5-H14        Repaired 00907970        Com 3onent Support 2HCB-3-H179      Repaired 00907972        8" Globe Valve        2PSV-1006      Part Replacement 00907972        8" Globe Valve        2PSV-1006      Replacement 00907980        8" Globe Valve        2PSV-1052      Part Replacement 00907980        8" Globe Valve        2PSV-1052      Replacement      1 00907981        8" Globe Valve        2PSV-1056      Part Replacement 00907981        8" Globe Valve        2PSV-1056      Replacement      j 00908463        1" Check Valve      2N2-1          Replacement      !
00908465        3" Piping            2HBB-7-3"      Repaired          l 00908465        3" Check Valve        2SA-69        Replacement      !
00908746        2" Globe Valve        2SI-69        Repaired        l 00908746        2" Globe Valve        2CV-5015-1    Repaired 00909000/      2" Globe Valve        2CV-5055-1    Replacement 00909001        2" Globe Valve        2CV-5056-2    Replacement 2" Globe Valve        2CV-5015-1    Replacement 2" Globe Valve        2CV-5016-2    P; placement 2" Globe Valve        2SI-68        Replacement 2" Globe Valve        2SI-70        Replacement
 
Attachment to 2CAN079403 J
J.0. NUMBER  DESCRIPTION        COMPONENT 1.D. ACTIVITY      l 2" Globe Valve    2SI-69        Replacement  ;
2" Globe Valve    2SI-71        Replacement  ,
00910426      Com ponent Support 2GCB-16-H11    Repaired 00911128      1" G:obe Valve    2SV-5633-1    Repaired      !
00911129      . I" Globe Valve    2SV-5633-2    Repaired      '
00911460      2" Gate Valve      2CV-5082      Repaired 00911737      Steam Generator    2E-24A        Repaired 00912810      Component Support 2HCB-9-H2      Repaired      !
l.
i                                                                !
,                                                                i l
l i
I l
l l
I l
l
 
Attachment to                                                                        ,
2CAN079403 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS (NIS-2 Forms Not Included in the 2R9 ISI Outage Summary Report)          i CLASS-1                                    ;
J.0. NUMBER      DESCRIPTION            COMPONENT I.D.      ACTIVITY 00865111          6" Globe Valve          2PSV-4633            Part Replacement      !
6" Globe Valve ~        2PSV-4634            Part Replacement -
CLASS-2 00853735          10" Gate Valve        2CV-1002            Part Replacement 00880688          2" Globe Valve        2CV-5035-1          Part Replacement Part Replacement l  00880718          2" Globe Valve        2CV-5055-1
;  00880725          2" Globe Valve        2CV-5015-1          Part Replacement      ,
00881293          2" Globe Valve -      2CV-5056-2          Part Replacement l
l 7
P 1
 
Attachment to 2CAN079403 1
(
NIS-2 FORMS CLASS-1 I
l i
1
 
                                                                                                                                            - Page 1 (Front)
:                              FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS                                                                            ;
As Required By The Provisions Of The ASME Code Section XI 1
: 1. Owner AP&I1Entergy Operations, Inc                                              Date      12/20/92 N-Rt.3 Box 137G, Russellville, AR 72801                                          Sheet        I                of            1 Adar
: 2. Plant      Arkansas Nuclear One                                                Unit          Two                                                      !
Rt. 3, Box 137G, Russellville, AR 72801                                          JO# 00858368 Address                                                  Rapair Orgeruzation P.O.No.. Job No..etc.
: 3. Work Performed by AP&I1Entergy Operations,Inc                                    Type Code Symbol Stamp                    N/A Nune                                    Authorization No -                        N/A                          1 Rt. 3. Box 137G, Russellville, AR 72801                                        Expriation Date N/A Addren
: 4. ' Identification of System RCS (TOP OF PRESSURIZER) l
: 5. (a) Applicable Construction Code          8" H3                19 68      Edition, W-70              Addenda, 1440                      codeCase      l (b) Applicable Edition of Section XI Utilized for Repairs of Replacements 19          86                                                            .
i
: 6. Identification of Components Repairs or Replaced and Replacement Components
                                                                                                                                                              )
ASME Code National                                    Repaired,              Stamped      i Name of              Name of                  Manufacturer            Board      Other              Year        Replaced,              (yes Component            Manufacturer                  Serial No.              No. Identification        Built      or Replacement            or No)      t 6* GLOBE              CROSBY                      N55605-            N/A        2PSV-4633            1975        REPAIRED                  YES VALVE                                            00-0003                                                                                                  }
6* GLOBE              CROSBY                      N55605-            N/A        2PSV-4633            1975        PART                      YES          '
VALVE                                            00-0003                                                          REPLACEMENT N                                                              "'^
N/A l
I
: 7. Description of Work MACHINED NOZZLE INSERT & REPLACED NOZZLE SEAT
: 8. Tests Conducted                  Hydrostatic l      l Pneumatic l    l NominalOperating Pressure            l Other l    l Pressure N/A              Psi    TestTemp N/A                    F NOTE: Supplemental Sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
(12/82)                            This Form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N.Y.10017 REPRINT 12/91
 
                                              . -                . _ . .          __        . __                      _ . .            _ - _ _              _ ~ ,
i
;                                                                                                                                                    Page 1 (Back) f n
i j                                                                        FORM NIS-2 (Back) l  9. Remarks N/A Apphcable Manufacture 4 Data Reports to be attached i
      ~
{
I h
e CERTIFICATE OF COMPLIANCE                                                                                      '
;                We certify that the statements made in the report are correct and this        ' REPAIR / REPLACE conforms to the rules of the j    ASAE Code, Section XI.                                                                  Repair or Replacement i!'
s Type Code Symbol Stamp                                                                    N/A j.
Certificate of Authorization No.                    N/A                    Expiration Date                                    N/A signed                                                                      Date              7!7                                  ,19 l-              owner fowner's Dc:Esnee. TGe                                                        (
;              D.B. Lomax - Manager, Engineering Programs
,                                                    CERTIFICATE OF INSERVICE INSPECTION i    1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State j    or Province of          Arkansas                  and employed by              Factory Mutual Engineering Association                                of I        Norwood. MA                                                                            AAt/ haveinspected the componentsdescribed
)    in this Owner's Report during the period                10/20/92                      107/7/F9 4'/M,'?# VIfM9v ,and state that
* i    to the best of my knowledge and belief, the Owner has performed examinations and talien correctivci mcfasures described in this 2    Owner's Report in accordance with the requirements of the ASME Code, Section XI.
i By signing this certificate neither the Inspector nor his employer makes any warranty, expressed orimplied, concerning the
!    examinations and corrective measures described in this Owner's Report.Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personalinjury or property damage or a loss of any kind arising from or connected with this
,  inspection
!.                                                                                                                                                                      ]
j
: 9. O.        [M          inspector's Sipiature Commissions            : NB-9947, Ark.-1133, "N" , "I" , "A" National Board, State, Province, and Endonemert.s i                                  J.0, Elhott 1
i      Date    M8                                    19 W G      V 1
4 4
4
 
Page 1 (Front)
FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI
: 1. Owner AP&IJEntergy Operations, Inc                                            Date      01/12/93 Name Rt. 3 Box 137G, Russellville, AR 72801                                      Sheet        1                of        1 Ahem
: 2. Plant        Arkansas Nuclear One                                            Unit            Two Rt. 3, Box 137G, Russellville, AR 72801                                        JO# 00859762 Address                                                  Repair Orgaruzadon P.O.No. Job No etc.
: 3. Work Performed by AP&I/Entergy Operations, Inc                                Type code Symbol Stamp                N/A Nana                                    Authorization No                      N/A Rt. 3, Box 137G, Russellville, AR 72801                                      Expriation Date                        N/A Ahem
: 4. Identification of System RCS (TOP OF PRESSURIZER)
: 5. (a) Applicable Construction Code SECT. HI                    19 68      Edition, W-70              Addenda, 1440                    CodeCase (b) Applicable Edition of Section XI Utilized for Repairs of Replacements 19        86
: 6. Identification of Components Repairs or Replaced and Replacement Components ASME Code National                                    Repaired,              Stamped Name of              Name of              Manufacturer            Board      Other              Year        Replaced,              (yes Component            Manufacturer              Serial No.              No. Identification        Built    or Replacement          or No) 6" GLOBE              CROSBY                  N55605-            N/A        2PSV-4634            1975        PART                    YES VALVE                                        00-0003                                                          REPLACEMENT N/A N/A N/A N/A
: 7. Description of Work REPLACED DISC INSERT
: 8. Tests Conducted            Hydrostatic l        l Pneumatic l    l Nominal Operating Pressure l          l Other l      l Pressure NA              Psi    TestTemp NA                    F NOTE: Supplemental Sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
(12/32)                      This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 REPRINT 12/91
 
i i'
i l                                                                                                                                                                              Page 1 (Bask) i j
l                                                                                                                                                                                                1 i
j
,                                                                                              FORM NIS-2 (Back) i-            9, Remarks NEW DISC INSERT S/N N95543-35-0004 l
Apphcable Manufacture's Data Repats to be anached c
3~
CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this          REPLACEMENT co-tbnni to the rules of the                                f AShE Code, Section XI.                                                                                Repair or Replacement l
7 Type Code Symbol Stamp                                                                                N/A                                                                      i Certificate of Authorization No.                                  N/A                    Expiration Date                                  N/A Signed                                A/
owner dr owners Desinnee. Tiile ' '
                                                                                                          . Date              4/tb -
                                                                                                                                /
                                                                                                                                                                  ,19      44, D.B. Iemax - Manager, Engineering Programs CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State                                            !
or Province of                        Arkansas                  and employed by            - Factory Mutual Engineering Association                                of        4 Norwood. MA -                                                                                            hayinsped th in this Owner's Report during the period                          10/20/92-                      to #fk' n.r"'h ff' @y components        V/# , and        described statethat to the best of my knowledge and belief, the Owner has performed examinations and tiken c6rrective ' mea'sures described in this                                                ]
Owner's Report in accordance with the requirements of the ASME Code, Section XI.                                                                                                1 By signing this certificate neitherthe Inspectornor his employer makes any warranty, expressed orimplied,concerning the examinations and corrective measures described in this Owner's Repet Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personalinjury or property damap or a loss of any kind arising from or connected with this inspection, e
k . O. [ /h -                                                        Commissions                    NB-9947, Ark.-l 133, "N" , "I" , "A" f                                          gp                                                              National Board, State. Province, and r-_'__
Date                S/,3                            19 98/
i A__-m._ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ - .                  _        -                #                                                    ,            e                v. e
 
Page 1 (Front)
FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPIACEMENTS As Required By The Provisions Of The ASME Code Section XI
: 1. Owner AP&I/Entergy Operations,Inc                                                    Date        05/18/93 Name Rt. 3, Box 137G, Russellville, AR 72801                                            Sheet          1              of                1 m
: 2. Plant        Arkansas Nuclear One                                                    Unit              Two Rt. 3, Box 137G, Russellville, AR 72801                                              JO # 00873971 Address                                                              Repas Orgamzation P.O.No Job No stc.
: 3. Work Performed by AP&I1Entergy Operations,Inc                                        Type Code Symbol Stamp                      N/A N=                                              Authorization No                          N/A-                            i Rt. 3. Box 137G, Russellville, AR 72801                                      ,
Expriation Date                            N/A                            l
                                        * "'                                                                                                                        l
: 4. Identification of System RCS (2CCA-15)
: 5. (a) Applicable Construction Code        sum                      19 71      Edition, S.73                  Addenda, 1388-2                  Code Case (b) Applicable Edition of Section XI Utilized for Repairs of Replacements 19              86
: 6. Identification of Components Repairs or Replaced and Replacement Components ASME Code        i National                                        R paired,              Stamped Name of                Name of              Manufacturer                Board        Other                Year          Replaced,            (yes Component            Manufacturer                Serial No.                  No. Identification              Built    or Replacement            or No) 3" GLOBE -          COPES                    7410-                    N/A          2CV-4651                1976. PART                      YES VALVE                VULCAN                  95326-8-1                                                                REPLACEMENT                              ;
N/A                                                                                    r N/A N/A N/A
: 7. Description ofWork REPLACED VALVE PLUG
: 8. Tests Conducted              Hydrostatic l              l Pneumatic        Nominal Operating Pressure            )(l Other l      l Pressure 2240                  Psi      Test Temp 650                    F NOTE: Supplemental Sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) informa-
    ~ tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
(12/82)                        This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 REPRINT 12/91
 
Page1(Back) i l
l l
i FORM NIS-2 (Back) i
,  9. Remarks REPLACED VALVE PLUG S/N 10-95326 WITH NEW PLUG S/N/ 8821-96587-1-1 i                                                                      ApphceNe Manufacture's Data Reports to be an.ched i
CERTIFICATE OF COMPLIANCE
(                  We certify that the statements rrmde in the report are correct and th -      REPLACEMENT confmns to the rules of the ASME Code, Section XI.                                                                    Repair or Replacement Type Code Symbol Stamp                                                                    N/A                                                            ,
Certificate of Authorization No.                        N/A                    Expiration Date                                      N/A Signed                    8[
Owner or 6wner's thstanee. TiiF '
                                                    /;                                Date              4/26                                ,19 - %
i D.B. Lomax - Manager, Engineering Programs                                                                                                            l CERTIFICATE OF INSERVICE INSPECTION                                                                ,
I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State
;      or Province of .          Arkansas                  ' and employed by                Factory Mutual Engineering Association                              of
!          Norwood. MA                                                                                        have              ed the componentsdescribed I      in this Owner's Report during the period                  10/20/92                      to    @ 1s//- ?f/f" 9'/.fF/9v ', and state that to the best of my knowledge and belief, the Owner has performed examinations a'nc taken corrective nicasures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty,- expressed orimplied, concerning the examinations and corrective measures described in this Owner's Report.Furthermore, neither the Inspector norhis employer j      shall be liable in any manner for any personalinjury or property damage or a loss of any kind arising from or connected with this
    ' inspection.
I. C.        [ /#,.                                                Commissions            NB-9947, Ark.-1133, "N" , "1" , "A" g                          gp                                                                      u. w no.re, si.ic, ermue, .no n.e_-
Date        S/3                              19 W                                                                                                            l l
1-                                                                                                                                                                      1 I
 
                        -      _ - - -          _                ~        . _ _        .-          -      .-              -      .            - . _ - - _ .
s Page 1 (Front)
;                            FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS J                                        As Required By The Provisions Of The ASME Code Section XI i                                                                                                                                                                      .
f l 1. Owner AP&UEntergy Operations, Inc                                                        Date      09/14/93 2                                                New of Rt. 3, Box 137G, Russellville, AR 72801                                              Sheet        1                            1
;                                              m e.
l 2. Plant Arkansas Nuclear One                                                              Unit            Two l      Rt. 3, Box 137G, Russellville, AR 72801                                                JO# 00874082
)                                              A& kens                                                          Repar Organizauon P.O.No.,Jub No.,etc.
l 3. Work Performed by AP&UEntergy Operations, Inc                                            Type Code Symbol Stamp                  N/A
;                                              New                                          Authorization No                        N/A
:      Rt. 3. Box 137G. Russellville, AR 72801                                              Expriation Date                        N/A                              l
!                                              AMras
: 4. Identification of System RCS (TOP OF PRESSURIZER) i
) 5. (a) Applicable Construction Code              smm                  19 68          Edition, W.70                  Addenda. 1440                        Code Case f        (b) Applicable Edition of Section XI Utilized for Repairs of Replacements 19                86                                                              ,
j 6. Identification of Components Repairs or Replaced and Replacement Components 1
,1 j                                                                                                                                                                ASME  !
Code l                                                                                National                                        Repaired,                Stamped Name of              Name of                  Manufacturer                Board        Other                Year        Replaced,                    (yes
!    Component            Manufacturer                  Serial No.                  No. Identification          Built      or Replacement                or No) 4                                                                                                                                                                      *
;    6" GLOBE            CROSBY                      N55605-                  N/A          2PSV-4633              1975        PART                      YES 1    VALVE                                            00 0002                                                                  REPI.ACEMENT 1    6" GLOBE            CROSBY                      N55605-                  N/A          2PSV-4634              1975        PART                      YES I    VALVE                                            00-0003                                                                  REPLACEMENT h/A
            'N                                                                  N/A l
              \
                    \                                                          N/A
: 7. Description of Work REPLACED NOZZLE INSERT FOR BOTH VALVES
' 8. Tests Conducted                  Hydrostatic l      l Pneumatic l        l Nominal Operating Pressure l            l Other l    l Pressure      N/A            Psi      Test Temp N/A                    F
;        NOTE: Supplemental Sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) informa-i        tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is i        recorded at the top of this form.
t i (12/82)                            This Form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N.Y.10017
)                                                                                                                                            REPRINT 12/91 i
i
 
l.
Page 1 (Back)
FORM NIS 2 (Back)
: 9. Remarks NEW NOZZLE INSERT S/N N96193-32-0013 FOR VALVE 2PSV-4633 AND Apphcable Manufactuds Data Reports to be attached NOZZLE INSERT S/N N96193-31-0002 FOR VALVE 2PSV-4634 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this        REPLACEMENT conforms to the rules of the ASME Code, Section XI.                                                                  Repair or Replacement Type Code Symbol Stamp                                                                  N/A Certificate of Authonzation No.      ,
N/A                    Expiration Date                                  N/A' Signed                                /)                                    Date
                                                                                            ~
                                                                                                . y/7                              ,19 k Owru/or Owner's Desagr@stle D.B. Lomax - Manager Engineering Programs CERTIFICATE 'OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of          Arkansas                  and employed by              Factory Mutual Engineering Association                            of Norwood, MA                                                                            aAp haveinspected the componentsdescribed in this Owners Report during the period                10/20/92                      to 7/7/fv '//fd'f M/V/vv ,and state that to.the best of my knowledge and belief, the Owner has performed examinations and taken corrective nicasdres described in this Owner's Report in accordance with the requirements of the AShE Code, Section XI.
By signing this certificate neither the inspector nor his employer makes any wananty, expressed orimplied, conarning the examinations and corrective measurps described in this Owners Report.Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
: 1. f)        / /A__h                    ture Commissions              NB-9947, Ark.-l 133, "N" , "I" , "A" National Board, State Province, and Endunements Date M                      8'              19 9 t/
0 V
 
(
Page 1 (Front)
FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI
: 1. Owner AP&I1Entergy Opaations, Inc                                                Date          01/20/93                                                                    ;
Name Rt. 3. Box 137G, Russellville, AR 72801                                          Sheet              1                  of                            I                      l Ahm
: 2. Plant        Arkansas Nuclear One                                                Unit                    Two Rt. 3, Box 137G, Russellville, AR 72801                                              JO# 00874083 Adkus                                                                Repar Orgamzauan P.O.No Joh No.,sec.
: 3. Work Performed by AP&I/Entergy Operations,Inc                                    Type Code Symbol Stamp                                          N/A Name                                      Authorization No                                                N/A Rt. 3. Box 137G, Russellville, AR 72801                                          Expriation Date :                                                N/A                        ;
Am.
: 4. Identification of System : RCS (TOP OF PRESSURIZER) t
: 5. (a) Applicable Construction Code smr.m                          19 68      Edition, W-70                        Addenda, 1440                                  codecase (b) Applicable Edition of Section XI Utilized for Repairs ofReplacements 19                86
: 6. Identification of Components Repairs or Replaced and Replacement Components                                                                                                  !
l ASME        i Code l
National                                                    Repaired,                    Stamped      l' Name of                Name of                Manufacturer            Board            Other                Year                Replaced,                    (yes Component              Manufacturer              Serial No.              No. Identification                  Built        or Replacement                      or No) 6* GLOBE                CROSBY                  N55605-              N/A        2PSV-4633                    1975.          PART                              YES VALVE                                            00-0002                                                                      REPLACEMENT                                      l
      \                                                                      "'^
l N                                                              "'^
N/A N/A
: 7. Description of Work REPLACED NOZZLE INSERT
: 8. Tests Conducted              Hydrostatic l          l Pneumatic l    l Nominal Operating Pressure l                  l Other l      l Pressure NA                Psi '  Test Temp NA                            F l          NOTE: Supplemental Sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) informa-                                        )
;            tion in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is l            recorded at the top of this form.
(12/82)                        This Form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N.Y.10017                              .
REPRINT 12/91
 
1 l
Page 1 (Back)  l I
i
                                                                                                                                                                    )
FORM NIS-2 (Back)
: 9. Remarks NEW NOZZLE INSERT S/N N96193-31-0002 Applicable Manufacture's Data Reports to be anached l
CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and th          REPLACEMENT confonns to the rules of the ASME Code, Section XL                                                                      Repair or Replacement e
T>pe Code Symbol Stamp                                                                      N/A Certificate of Authorization No.                      N/A                    Expiration Date                                    N/A Signed                A /,                  J' Date              4fl8                                  ,19 94 Owner 6r Owners Dessanee. tac '                                                          '
D.B. lomax - Manager, Engineermg Programs                                                                                                              t CERTIFICATE OF INSERVICE INSPECTION                                                                                  !
I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State                                !
or Province of            Arkansas                    and employed by              Factory Mutual Engineering Association _                              of    ,
Norwood, MA to 4 5 % ,e g/ fI eiped tpe componentsdescribed in this Owner's Report during the period                10/20/92                                                i7I#MA/M                    , and state that    ;
to the best of my knowledge and belief, the Owner has performed examinations and taken corrective' meksures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed orimplied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personalinjury or property damage or a loss of any kind arising from or connected with this inspection.
k , C,          M                                              Commissions                  NB-9947, Ark.-l 133, *N" , "1" , "A" g                          gg                                                                        National Board, State, Province, and Endonerneras Date        S/3                              19 W
 
l l
I                                                                                                                                      Page 1 (Front) l FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI
: 1. Owner AP&IJEntergy Operations, Inc                                            Date      05/20/93                                                j Name Rt. 3 Box 137G, Russellville, AR 72801                                      Sheet        1              of        I wre=
: 2. Plant      Arkansas Nuclear One                                              Unit            Two l
Rt. 3, Box 137G, Russelhille, AR 72801                                        JO# 00887843 Address                                                  Repair Organnauan P.O.No Job No.,etc.
: 3. Work Performed by AP&IJEntergy Operations, Inc                                Type Code symbol stamp              N/A Nan
* l Authorization No                      N/A Rt. 3. Box 137G, Russelhille, AR 72801                                      Expriation Date                      N/A wre=
l j
: 4. Identification of System RCS (TOP OF PRESSURIZER)
: 5. (a) Applicable Construction Code        s mr.m              19 68      Edition, W.70              Addenda, 1440                    Code case
!      (b) Applicable Edition of Section XI Utilized for Repairs of Pqlacements 19        86
: 6. Identification of Components Repairs or Replaced and Replacement Components l
ASME Code l                                                                      National                                    Repaired,            Stamped Name of              Name of                Manufacturer            Board      Other              Year        Replaced,            (yes Component            Manufacturer              Serial No.              No. Identification        Built    or Replacement          or No) 6" GLOBE              CROSBY                  N55605-            N/A          2PSV-4634            1975      REPLACED              YES VALVE                                        00-0001 6" GLOBE              CROSBY                  N55605-            N/A          2PSV-4634            1975        REPLACEMENT YES VALVE                                        00-0003 N/A N/A N/A
: 7. Description of Work REPLACED VALVE WITH REBUILT SPARE VALVE                                                                                      I
: 8. Tests Conducted            Hydrostatic l        l Pneumatic l    l Nominal Operating Pressure l )(l l                                Other l      l Pressure    2240        Psi    Test Temp 650                  F NOTE: Supplemental Sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) informa-tion in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
(12/82)                      This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 REPRINT 12/91
 
-                                                                                                                                                                    l
.                                                                                                                                                      Page1(Back) i.
i i
FORM NIS-2 (Back)
: 9. Remarks NV-1 MANUFACTURERS DATA REPORT PREVIOUSLY SUBMITTED Applicable Manufacture's Data Reports to be attached 4
4 CERTIFICATE OF COMPLIANCE q                We certify that the statements made in the report are correct and th          REPLACEMENT confonns to the rules of the AShE Code, Section XI.                                                                      Repair or Reptacement I
  . Type Code Symbol Stamp                                                                        N/A Certificate of Authorization No.                      N/A                    Expiration Date                                    N/A Signed                  jj [                    J                            Date                dfg6                              ,19 $                    ,
I Owner of Owner's Destance. Title                                                        /
l              D.B. Lomax - Manager, Engineezing Programs 4
:                                                    CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State f
or Province of            Arkansas                  and employed by                Factory Mutual Engineering Association                            of Norwood, MA                                                                                4A# haveinspected the componentsdescribed i    in this Owner's Report during the period                10/20/92                          to 7/7/ N Y M d f V /fv/f v , and state that to the best of my knowledge and belief, the Owner has performed examinations and talcen c'orrective' meisures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed orimplied, concerning the examinations and corrective measures described in this Owner's Report . Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personalinjury or property damage or a loss of any kind arising from or connected with this inspection.
k, d,          [                                                Commissions                  NB-9947, Ark.-l133, "N" , "1" , "A" M
V inspector's siparure                                                      National Board, State. Provuwe, and Endorurneiss
.                                    J.O. Elhott Date              SM~                          199V
 
Page 1 (Front) i                                  FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS i                                        As Required By The Provisions Of The ASME Code Section XI
: 1. Owner AP&IJEntergy Operations, Inc                                                  Date    09/09/93-
,                                              N_                                                                                                                ,
,i      Rt. 3. Box 137G, Russellville, AR 72801                                            Sheet        1                of        1                            I i                                            44*.=                                                                                                              ;
l j    2. Plant        Arkansas Nuclear One                                                  Unit            Two
      - Rt. 3, Box 137G, Russellville, AR 72801                                              JO# 00887846                                                      !
r                                            Addreas                                                        Rapear Organizaban P.O.No Job No..etc.
Ii 3. Work Performedby AP&IJEntergy Operations,Inc                                          Type Code Symbol Stamp N/A                            ,
N=                                            Authorization No                    N/A
.l Rt. 3. Box 137G, Russellville, AR 72801                                _
Expriation Date                      N/A-l                                            Ad*=
l 4. Identification of system RCS (TOP OF PRESSURIZER)                                                                                                          >
1
: 5. (a) Applicable Construction Code        SM HI                    19 68      Edition, W-70                Addenda, 1440                      codecase (b) Applicable Edition of Section XI Utilized for Repairs of Replacements 19              86-j    6. Identification of Components Repairs or Replaced and Replacement Components f                                                                                                                                                      ASME l                                                                                                                                                        Code i                                                                              National                                    Repaired,                Stamped 1-      Name of                Name of                Manufacturer              Board        Other              Year        Replaced,                (yes l    Component              Manufacturer              Serial No.                No. Identification            Built    or Replacement              or No) l      6" GLOBE                CROSBY                  N55605-              N/A          2PSV-4633          1975        PART                    YES        l 1      VALVE                                            00 0001                                                            REPLACEMENT N/A N/A                                                                              >
                                                                              "'^
l                \                                                          "'^
:                      N                                                                                                                                        .
: 7. Description ofWork REPLACED DISC INSERT & BELLOWS ASSEMBLY                                                                                              i
: 8. Tests Conducted              Hydrostatic l        l Pneumatic l      l Nominal Operating Pressure l          l                                      l 1
Other l    l Pressure      NA            Psi      Test Te'm p NA                F
;        NOTE: Supplemental Sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) infonna-j          tion in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is
!          recorded at the top of this form.                                                                                                                      ;
i                                                                                                                                                                I (12/82)                        This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y,10017 REPRINT 12/91 f
i 4
 
    .                .            -      . .              . - . .                .      ~.                    ~_. . -                        .            -    -.
i i                                                                                                                                                        Page 1 (Back) j-4 i
i FORM NIS-2 (Back) i;
!  9. Remarks NEW DISC INSERT S/N N96193-32-0011 AND NEW BELLOWS S/N KS6362-35-0007
!                                                                        Apphcable Manufactwo's Data Reports to be atta&od i
l I
CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and th            REPLACEMENT cafens to the ndes of the ASME Code, Section XI.                                                                      Repair or Replacement i
Type Code Symbol Stamp                                                                        N/A Certificate of Authorization No.                            N/A                  Expiration Date                                  N/A Signed                  ]/ /                    '
A                            Date                4/26
                                                                                                                                              ,19    $$
Owner ogDwner% Desianee. Tatie D.B. Iomax - Manager, Engineering Programs CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of            Arkansas                      and employed by                Factory Mutual Engineering Association                            of      i Norwood. MA                                                                                  m have in in this Owners Report during the period                      10/20/92                    to #rM N'spected the componentsdesente to the best of my knowledge and belief, the Owner has performed examinations and tal[en co'rrective incasures desented in this Owner's Poort in accordance with the requirements of thi ASME Code, Section XI.
By signing this certificate neither the Inspector ncr his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described inthis Owners Report.Furthermore, neither the Inspe: tor norhis employer shall be liable in any manner for any personalinjury or property damage or a loss of any kind arising from or connected with this inspection.
k . O. [ /#,                                                        Commissions                NB-9947, Ark.-Il33, "a t" , "I" , "A"
    'y                          . Inspector's Sipatwe                                                        National Board, State Province, and Endorsements J.O. Elhott Date -      8/3                                  '19 9 Y
 
Page 1 (Front)
FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI Date      05/13/93
: 1. Owner AP&UEntergy Operations,Inc New                                                                                                              of      1 Sheet        I Rt. 3, Box 137G, Russelhille, AR 72801 Address Unit            Two
: 2. Plant      Arkansas Nuclear One JO# 00889664 Rt. 3, Box 137G, Russe!hille, AR 72801                                                                                    Repar Orgaruzauon P.O.No.Jub No. etc.
Address Type code Symbol stamp                                      N/A
: 3. Work Performed by        AP&UEntergy Operations, Inc Authorization No                                          N/A N=*
l                                                                                                        Expriation Date                                            N/A l      Rt. 3. Box 137G, Russellville, AR 72801 Address
: 4. Identification of System RCS (
Addenda, 1359-1          code Case sm m                                          Edition, S.67 19 65
: 5. (a) Applicable Construction Code 86 (b) Applicable Edition of Section XI Utilized for Repairs of Replacements 19
: 6. Identification of Components Repairs or Replaced and Replacement Components ASME Code Repaired,        Stamped National                                                                              (yes Other                                      Year      Replaced, Manufacturer              Board Name of                                                                                                                    Built  or Replacement      or No)
Name of                                                                                    No. Identification Manufacturer                                    Serial No.
Component 1972    PART                YES 21083              N/A          2E-24A STEAM              COMBUSTION                                                                                                                          REPLACEMENT GENERATOR          ENGINEERING N/A
        \\                                                                                                                                                                                        f N/A N/A N/A
                      \
: 7. Description of Work          REPLACED ONE PRIMARY MANWAY STUD & NUT Hydrostatic l                                              l Nominal Operating Pressure l l
: 8. Tests Conducted                                                      l Pneumatic l                                                                    F jPressure              N/A        Psi    Teo Teo N/A Other l NOTE:  Supplemental Sheets in form of lists, sketches, or drawings                                                                              d dhmay bbe  r of used, sheets is provided (1) tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbere an t e num recorded at the top of this form.
This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New (12/82)
REPRINT 12/91
  ~~                                        - - - - - _ - - _ _ _ _ _ _ _ _                                            - - - - ~ - - - . _ _ _ _ _ _ _                          _
 
l l
Page 1 (Back) 1 FORM NIS-2 (Back)
: 9. Remarks REPLACED STUD & NUT # AP24-1 WITH NEW STUD                                                                                                                !
Applicable Manufacture's Data Reports to te attached i
l                                                          CERTIFICATE OF COMPLIANCE .                                                                                  ,
l                We certify that the statements made in the report are cotreet and this              REPLACEMENT conforms to the rules of the ASME Code, Section XL                                                                    - Repair or Replacement                                                  ,
T 3pe Code Symbol Stamp                                                                        N/A Certificate ofAuthorization No.      ,                N/A                    Expiration Date                                      N/A
* Signed            _
Date                    7/r/                              ,19 Owner 4r Owners Designee /7itle                                                              /
D.B. Lomax - Manager, Enginesing Programs
;                                                                                                                                                                        1 CERTIFICATE OF INSERVICE INSPECTION                                                                              1 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of          Arkansas                    and employed by              Factory Mutual Engineering Association                                  of Norwood, MA                                                                                4@# haveinspected the components described in this Owner's Report during the period                10/20/92                            to7hM M16M M/MM ,and statethat to the best of my knowledge and belief, the Owner has performed examinatioris 'and tak'en corrective incasures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.                                                                                  v By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report Furthermore, neither the Inspector nor his employer                                          +
shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this
    ' inspeClion.
    /f 9    0.      [M          Inspector s Signature Commissions                    NB-9947, Ark.-l 133, "N" , "I" , "A" Nauonal Board, State, Province, and Lidu. . w.;.
V                                J.O. Elliott                                                                                                                        4 Date d              JP                        19'1'f 4      0
 
Page 1 (Front)
FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI 1, Owner AP&I1Entergy Operations, Inc                                                                                    Date          05/13/93 Name Rt. 3, Box 1370, Russellville, AR 72801                                                                              Sheet            1                of          1                              l Address                                                                                                                                        :
: 2. Plant                Arkansas Nuclear One                                                                              Unit                Two
      -Rt. 3, Box 137G, Russellville, AR 72801                                                                                JO# 00889664 Addreas .                                                                            Repaar Orgamzation P.O.No.. Job No.,asc.                1
: 3. Work Performed by AP&I1Entergy Operations, Inc                                                                          Type Code Symbol stamp                    N/A Name                                                            Authorization No                          N/A Rt. 3. Box 137G Russellville, AR 72801 -                                                                              Expriation Date                            N/A Ahas
: 4. Identification of System RCS (
: 5. (a) Applicable Construction Code                          SECT III                19 65                      Edition, S-67                    . Addenda,1359-1                    Code case (b) Applicable Edition of Section XI Utilized for Repairs of Replacements 19                                                      86-
: 6. Identification of Components Repairs or Replaced and Replacement Components ASME Code National                                                Repaired,              Stamped Name of                                Name of                Manufacturer                                Board            Other              Year        Replaced,                (yes Component                                Manufacturer -            Serial No.                                No.      Identification            Built    or Replacement            or No)        ,
STEAM                                    COMBUSTION              21083                        N/A                    2E-24A                    1972        PART                      YES i  GENERATOR                                ENGINEERING                                                                                                        REPLACEMENT I
N/A
                                                                                                    "'^
N                                                                                        N/A N/A
                                    \
: 7. Description of Work REPLACED ONE PRIMARY MANWAY STUD & NUT
: 8. Tests Conducted                              Hydrostatic l          l Pneumatic l                  l Nominal Operating Pressure l                      l Other l      l Pressure          N/A                      Psi      TestTemp N/A                          F NOTE: Supplemental Sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) informa-tion in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
(12/82)                                        This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 REPRINT 12/91            ,
              . . ~ , . . . , _ . . _ , - ,        .          .-        -,..c-..    .  , - - . . , . _ . . . .    .  ,c,  ._.,.#,.-.      #  . e.
 
j                                                                                                                                                                  Page 1 (Back) l FORM NIS-2 (Back) i
: 9. Remarks REPLACED STUD & NUT # AP24-1 WITH NEW STUD appuc.uc wanur.cture. n.a nepons to he anus.d l
CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this            REPLACEMENT conforms to the rules of the l        ASME Code, Section XI.                                                                          Repair or Replacement l
l Type Code Symbol Stamp                                                                            N/A Certificate ofAuthorization No.            ,                N/A                      Expiration Date                                N/A Signed                _
Date            7/r/                                , 19 owner 4r owner's Designee.4 rue                                                        /
l                    D.B. Lomax - Manager, Engineering Programs l
CERTIFICATE OF INSERVICE INSPECTION l        I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure V                        ' essel Inspectors and the State
!        or Province of                  Arkansas                  and  employed        by          Factory Mutual Engineering Association                            of l                Norwood, MA                                                                                  4A!# haveinspected the componentsdescribed in this Owner's Report during the period                      10/20/92                        to7hN #1bdM VIfMvf/ ,and statethat to the best of my knowledge and belief, the Owner has performed examinations 'and talien corrective incasures described in this l-        Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed orimplied, concerning the examinations and corrective measures described in this Owner's Report, Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
9C                [M                                                          Commissions            NB-9947, Ark.-l 133, "N" , "I" , "A" g                                        or'g                                                              National Board, State, Province, and Endorserneras Date d_                    JP                      19 i 'f 4        0
    ~          m                                                                                                                                    ,          m              m
 
Page 1 (Front)
(
l FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS
                                    'As Required By The Provisions Of The ASME Code Section XI '
, 1. Oner AP&IJEntergy Operations,Inc                                                  Date      05/18/93 Name l    Rt. 3, Box 137G,' Russellville, AR 72801                                        Sheet        1                of        1
!                                            m.
: 2. Plant          Arkansas Nuclear One                                              Unit            Two Rt. 3, Box 137G, Russellville, AR 72801                                          JO# 00890731
                                            /4 dress                                                    Repar Orgamzataan P.O.No., Job No.,etc.
: 3. Work Performed by AP&IJEntergy Operations, Inc                                    Type Code Symbol stamp                  N/A N=                                      Authorization No                        N/A i
Rt. 3, Box 137G, Russellville, AR 72801                                        Expriation Date                        N/A l                                            Mare.
: 4. Identification of System LPSI(2CCA)
: 5. (a) Applicable Construction Code          sm. m                19 71      Edition, S.72                  Addenda, 1535-2                codecase          :
(b) Applical.le Edition of Section XI Utilized for Repairs of Replacements 19          86 j 6. Identification of Components Repairs or Replaced and Replacement Components l
ASME            '
Code i                                                                          National                                      Repaired,              Stamped j    . Name of              Name of                Manufacturer            Board      Other                  Year      Replaced,            (yes l  Component              Manufacturer              Serial No.              No. Identification            Built  or Replacement          or No) 12" CHECK              ATWOOD                  7-626                N/A        2SI-15D                1973        PART                    YES VALVE                  MORRILL                                                                                      REPLACEMENT                              >
N/A N/A N/A i
: 7. Description of Work REPLACED VALVE DISC
: 8. Tests Conducted            Hydrostatic l          l Pneumatic l    l Nominal Operating Pressure lXl Other l        l Pressure 2240            Psi    Test Temp 537                    F NOTE: Supplemental Sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
(12/82)                      This Form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N.Y,10017                                l l
REPRINT 12/91 J
f                                                      __              .                                  _
                                                                                                                                                                -,i
 
\'
Page 1 (Back)
FORM NIS-2 (Back)
: 9. Remarks REPLACED VALVE DISC S/N 7626 WITH NEW DISC SERIAL # 77842-3 Applicable Manuracture's Data Repcsts to be attaded
{
CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and th        REPLACEMENT conforms to the rules of the                              ,
AShE Code, Section XI.                                                                    Repair or Replacement Type Code Symbol Stamp                                                                    N/A                                                                  ;
Certificate of Authorization No.                      N/A                      Expiration Date                                N/A Signed                        N h,            -
Date              4f2J                              ,19 @                      {
Owner or Ownsts Desianes, Tale          '
l D.B. Lomax - Manager, Ew lug Programs CERTIFICATE OF INSERVICE INSPECTION I
1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of            Arkansas                  and employed by                Factory Mutual Engineering Association                            of        i Norwood, MA                                                                                AW' have inspected the components described                      l in this Owner's Report during the period                10/20/92                        to 7/7/sv $ T/?f' M/W94/ ,and state that                                !
I  to the best of my knowledge and belief, the Owner has performed examinations and talien corrective incas 6res described in this                                  )
Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed orimplied, concerning the examinations and corrective measures described inthis Owner's Report.Furthermore, neither the Inspector norhis employer shall be liable in any manner for any personalinjury or property damage or a loss of any kind arising from or connected with this inspection.
9 . 0 . [, .2^ h          _
Commissions                  NB-9947,_ Ark.-l 133, "N" , "1" , "A" f                                  or-    use                                                      National Board State. Province, and Endonemeens l
Date        4"/1                              19 9Y l
!                                                                                                                                                                  l
 
Y Page 1 (Front)
FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI
: 1. Owner AP&I1Entergy Operations,Inc                                                          Date                  04/05/94 Name Rt. 3, Box 137G, Russellville, AR 72801                                            Sheet                      1              of          1 Addren
: 2. Plant            Arkansas Nuclear One                                                    Unit                        Two Rt. 3, Box 137G, Russellville, AR 72801                                              JO# 00898754                                                                                i Address                                                                      Repaar Orgamzataan P.O.No Job No stc.
3 Work Performed by AP&I/Entergy Operations, Inc                                            Type Code symbol stamp                              N/A Nmne                                            Authorization No                                  N/A Rt. 3. Box 137G Russellville, AR 72801                                            Expriation Date                                    N/A Adaren
: 4. Identification of System HPSI (2CCA-22 )
: 5. (a) Applicable Construction Code              sen                19 89            Edition, NO                              Addenda, NA                                Code case (b) Applicable Edition of Section XI Utilized for Repairs of Replacements 19                          86 l  6. Identification of Components Repairs or Replaced and Replacement Components l
ASME Code National                                                      Repaired,                        Stamped Name of              Name of              Manufacturer                Board        Other                          Year          Replaced,                      (yes Component                Manufacturer              Serial No.                    No. Identification                      Built    or Replacement                      or No)
!      3" CHECK                  VELAN-                2294                N/A                2SI 13A                          E          REPLACED                          YES l      VALVE                                                                                                                    1971 l      3" CHECK                  ANCHOR                ET-752-1-2          N/A                2SI-13A                          1994        REPLACEMENT YES VALVE                    DARLING N/A N/A L                        N                                                  "'^
: 7. Description of Work CUT-OUT & REPLACED VALVE
: 8. Tests Conducted                  Hydrostatic l )( l Pneumatic l          l Nominal Operating Pressure l                            l Other l      l Pressure 2937                Psi        TestTemp AMB                                F l
NOTE: Supplemental Sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is l            recorded at the top of this form.
( a,,52)                          This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 REPRINT 12/91
 
l-                                                                                                                                                                Page 1 (Back)
I l                                                                          FORM NIS-2 (Back)
: 9. Remarks NPV-1 MANUFACTURES DATA REPORT FOR REPLACEMENT VALVE ATTACHED i                                                                        Apphcable Manufacture) Data Reports to be attadaed l
l CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this          REPLACEMENT conforms to the rules of the ASME Code, Section XI.                                                                    Repair or Rg!-'
l Type Code Symbol Stamp                                                                      N/A l-I l        Certificate of Authorization No.                        N/A                      Expiration Date                                          N/A Signed                            of I Owner or Owndr's Desinnee Tale - '
                                                              /)                        Date            4/t$                                        ,19 34 j
D.B. Lomax . Manager, Engineenng Programs
!                                                        CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State l        or Province of            Arkansas                  and employed by                Factory Mutual Engineering Association                                        .of l            Norwood. MA                                                                                >*# have inspected the components descriW I        in this Owner's Report during the period                  10/20/92                        to 7h/rv I/Ih# '/If4'/99 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective ' measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, uviswsd or implied, concerning the examinations and corrective measures described in this Owner's Report.Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personalinjury or property damage or a loss of any kind arising from or connected with this inspection.
9 . O.          [                                              Commissions                NB-9947, Ark.-l133, "N" , "I" , "A" g                                    or'g                                                                  National Board, State, Prownce, and Endorsements Date          S/3                              19 9 '/
 
2 s 1 - /. M
'.              FORM NPV 1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS CR VALVES *rf f 7,3 y.f.g l                              As Required by the Provisions of the ASME Code, Section lit, DMolon 1 l                                                                                                                                  Ps.          of I
,        ,, u,,g m w                      w Anchor / Darling Valve Co.e 701 First St., Williamsporte PA 17701 4                                                                                  w    ens        m = c.r.nem mi l"
: 2. Mensm ,,                  Enterey Operations. Inc. , RT. 3. Box 137G, Russellville. AR 72801
]                                                                            in    me        .epww      y o- -i
;        3, t ,,,,,,, ,,io,,,,,,,,          Arkansas Nuclear One. S. of Jct. Hwy. 64W & 3335. Russellville, AR
:                                                                                          saem. .w                                                      72801
;          4. Modd No.. swies No., w Type              SC                    %            W9324163        %,        B                  w N/A i
!          s. Asue code secean m. DMenon 1:                      1989                        N/A                  1                          N/A
:                                                              seen as                i.eeenen es.m              is e      -
icoescomea :
4          e. Pume w weeve          Valve                %e                              3"          w ,,,              3"
!                                                                                        eu                                  en.i i          7, u,,,,w      %        SA351-CF8M            %              SA182-F316          m    SA182-F347              %        Cover Studs-SA453-660B i
Cover Nuts-SA194-8M          4 l
j                    tel                          (b)                            (c)                      (d) .                          fel                  '
q Cert.                      Net'l                          Body                      Bonnet                            Disk
  ;              HoWor's                      teerd                          serial                    serial                          satel
:                sw w us.                      no.                            no.                        no.                              no.                  ,
i            E- T 7 52 1                    N/A                              1                        1                  _            1            _
j
      ' ( E-T7 52- 1-2
_        N/A                    --_      2                        2                              2            ~ __)
j                                                                                                                                                                  1 2                                                                                                                                                              .
l k
i                                                                                                                                                                l 2                                                                                                                                                                  l 3
1 i
4 i
?
i i
l I
i a
3
          *C--
T mm informenon m form of keta, sketches, or crewege may be used proveed it s eue se 8 % x 11. (2) mformenon m nome I ttwough 4 on ene Data Report a mesuced on eacn sheet. i31 each eneet is nummered and the numeer of sheets a recorded et the too of ttmo form.
i
,          12/sel                    The form tE00037) mov be out.med from the Oreer Dept.. ASME 22 Lew Onve, som 2300. Ferrfeed. NJ 07007 2300.
1 a
t
 
PORM NPV 1 (beek)
: e. nevnerte        Hinae Pin Cover SA182-F316
: s. ossign oomseen.            3700              g          650                                                    2500 isso ww
                                                                                          ., e, ,e,,e              eiese                        m
                                                                    =me-wees
: 10. Com working proneure            6000              g ,,igo.,
: 11. Hy westeneinet            9000        g , oi,, m ,,,,                              6600                                        g camnCanOn or Ossaan
                                                                                                        .                                              1 Design speamoseen ewoned by William R. Rowlett. Jr. P.E. stees Arkansat                                    neg. no,    6436 Design mepat owened t,y      Theron C. Bartlett II                          p,t stete    PA              n6g.no. 039036-E l
CetTIRCATE OF SHOP COMPUANCE
* I we carefy that the statemente made in this report are correct and thet tNo purnp or valve confonne to the ruise for construenon              I et v. Asus Code, seceen m. Div i n 1.
N Catenante of Anhortantion No            N1712                                            te,i,ee      4/15/95 o,,,c?.25-9f            yeme    Anchor /Darlina Valve Compangi,ned                        #Y A-(N CarWRosse Hoteert                                  lawhenmed ressessmeeves                  ,
                                                  ,      CERTFICATE OF SHOP WSPECDON 1, the undweigned, holding a valid commise6en issued by the National Board of Boiler and Pressure Vessel Inspectore and                      1 ve stste m ,,                  Pennsv1vania                              end em,ioyed b, Commercial Union Ins. Co.
          ,,              Boston. Mass.                                have ine,eeted e. ,um,, o, veeve, described in inia oste no, ort on
        /2-Y4-931 ME is 2,%'.. and state that to We Inst of my knowiedge and tweef, the Catmcete Holdw hee constructed this purno, or velve,in accoreence with the ASME Code, Seceen Ill, Divielen 1.
By signmg this certpfleets, neither the inspector nor his employer makes any warranty, empressed or implied, concoming the component described in this Date neport. Furthermore, neither the inspector nor his employer ehed be Aeble in any menner for any personal injury or property                loss of any kind arising from or connected with this inspeccon.
Date S'                                M//W C-,.T      .? ^'- .;    Pennsylvania 2392 cwm, /                                              ~,...._,..r.o...-,
(1) For manuelty operoted valves oney.
                                                      /
i
 
4 Page 1 (Front)
}
;                              FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI
: 1. Owner AP&I1Entergy Operations,Inc                                                Date      04/22/94 Name Rt. 3, Box 137G, Russellville, AR 72801                                          Sheet        1              of                1-Ahas
: 2. Plant        Arkansas Nuclear One                                                Unit            Two Rt. 3, Box 137G, Russellville, AR 72801                                          JO# 00903058 Rapaar C..        P.O.No., Job No.,asc.
Ahas
: 3. Work Performed by AP&IJEntergy Operations, Inc                                  Type Code Symbol Stamp                N/A                                  )
N=                                        Authorization No -                  N/A Rt. 3 Box 137G, Russellville, AR 72801                                          Expriation Date                      N/A Ah 4.' identification of System HPSI ( 2CCA-22)
: 5. (a) Applicable Construction Code 8T                        19 71        Edition      S-71            Addenda, 1535-2                        code Case (b) Applicable Edition of Section XI Utilized for Repairs of Replacements 19            86
: 6. Identification of Components Repairs or Replaced and Replacement Components ASME Code National                                      Repaired,                  Stamped Name of              Name of              Manufacturer            Board        Other            Year        Replaced,                  (yes Component            Manufacturer              Serial No.              No. Identification            Built      or Replacement                or No) 12" CHECK            ATWOOD                  3-626              N/A          2SI 15A              1973        PART                        YES VALVE                MORRILL                                                                                    REPLACEMENT N/A
                                                                        "'^
            \                                                            N/A
                                                                        "'^
N
: 7. Description ofWork REPLACED VALVE BONNET, DISC & STUDS & NUTS
: 8. Tests Conducted            Hydrostatic l X l Pneumatic l        l Nominal Openting Pressure R Other l      l Pressure 2244            Psi      Test Temp 750                    F NOTE: Supplemental Sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
(12/82)                      This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 REPRINI' 12M)1
 
4 I
b                                                                                                                                                    Page 1 (Back)  !
i e
i i
i                                                                      FORM NIS-2 (Back) l i
4 4
: 9. Remarks NEW VALVE BONNET S/N 2, NEW DISC S/N 77842-1                                                                                                            l
;                                                                    Applzable Manufassure's Data Reports to be anu                                                  ]
J i
i 4
i 4
CERTIFICATE OF COMPLIANCE
;                We certify that the statements made in the report are correct and this              REPLACEMElfr conforms to the rules of the                      !
j    ASME Code, Section XI.                                                                Pepair or Replacernent 4
j f  , Type Code Symbol Stamp                                                                  N/A                                                                    l Certificate ofAuthorization No.                o    N/A                    Expiration Date                                    N/A Signed                I                          /)                          Date        _
                                                                                                    ,a    J                              ,19 j              D.B.
or ownes D.=nse. Taie        /
                            - Manager, Engmeenng Programs p                                                                        ;
i CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of          Arkansas                  and employed by                Factory Mutual Engineering Association                                of j          Norwood. MA                                                                                mar haveinspected the components described 1    in this Owners Report during the period                10/20/92                      to WM "df/"Y FItd94/                                  , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken'correctis niicasures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
: q.        Bysigning thiscertificate neitherthe Inspectornorhis employer makes any warranty, expressed orimplied,concerningthe j    examinations and corrective measures described in this Owner's Report, Furthermore, neither the Inspector nor his employer
:    shall be liable in any manner for any personal injury or property damage or a . loss of any kind arising from or connected with this
    ' inspection, l
i 9, C        [            Impset#s sipature Commissions -                NB-9947, Ark.-l133, "N" , "1" , "A" National Bonni, State. Provare, and Emdursammes f7 t/                                10. Elhott Date QM                3                      19 9 8/
f
 
Page 1 (Front)
FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI
: 1. Owner AP&IJEntergy Operations, Inc                                            Date      04/05/94 Name                                                                                                      1 Rt. 3, Box 137G, Russellville, AR 72801                                      Sheet        1              of          1 Ahm
: 2. Plant        Arkansas Nuclear One                                            Unit            Two                                                ,
1 Rt. 3, Box 137G, Russellville, AR 72801                                        JO# 00905586 Address                                                  Repar Organnauan P.O.No., Job No etc.
: 3. Work Performed by AP&I1Entergy Operations, Inc                                Type code Symbol stamp                N/A Nan
* Authorization No                      N/A Rt. 3. Box 137G, Russellville, AR 72801                                      Expriation Date                        N/A Addre
: 4. Identification of system PRESSURIZER SPRAY SYSTEM (2CCA-15 )
: 5. (a) Applicable Construction Code Atsc                        19 69      Edition, SUPP 1 & 2 Addenda, NA                              code case (b) Applicable Edition of Section XI Utilized for Repairs of Replacements 19        86
: 6. Identification of Components Repairs or Replaced and Replacement Components AShE Code National                                  Repaired,              Stamped Name of              Name of              Manufacturer            Board      Other              Year      Replaced,              (yes Compnent              Manufacturer            Serial No.                No. Identification          Built    or Replacement          or No)
COMPONENT            BECHTEL                NA                  N/A          2CCA-15-H49        E          REPAIRED                NO SUPPORT                                                                                            1972 N/A N/A N/A N/A
: 7. Description ofWork MODIFIED SUPPORT
: 8. Tests Conducted            Hydrostatic l        l Pneumatic l    l Nominal Operating Pressure l        l Other l      l Pressure NA              Psi    Test Temp NA                  F NOTE: Supplemental Sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) informa-tion in items 1 through 6 on this report is included on cach sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
(12/82)                      This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 REPRINT 12/91
 
I Page 1 (Back) i l
l I-l
;                                                                          FORM NIS-2 (Back) l
: 9. Remarks NA Apphcable Manufactites Data Reports to be anached                                                    l l
l t
CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this                        REPAIR          confonns to the niles of the ASME Code, Section XI.                                                                            Repair or Replacement                                              !
i l      T 3pe Code Symbol Stamp                                                                            N/A Certificate of Authorization No.                          N/A                  Expiration Date                                        N/A Signed                        I                      - /)                      Date                              M                      , 19 %
owner or 04mr4 Desianee. Tale-'          /                                                          '
D.B. lomax - Manager, Engmeenng Programs CERTIFICATE OF INSERVICE INSPECTION                                                                                !
l 1, the undersigned, holding a valid comrmssion issued by the National Board of Boiler and Pressure Vessel Inspectors and the State                                  e or Province of            Arkansas                      and employed by            Factory Mutual Engineering Association                                    of    :
Norwood. MA                                                                                          Aarhave nspected the componentsdescribed                    i in this Owner's Report during the period                    10/20/92                            to    7/WFv Y,j#df MMff                          , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective incasures described in this Owners Report in accordance with the requirements of the ASME Code, Section XI.
* By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the                                    ;
examinations and corrective measures described inthis Owners Report.Furthermore, neither the Inspector norhis employer                                              ,
shallbe liable in any manner for any personalinjury or property damage or a loss of any kind arising from or connected with this                                    ;
inspection.
!'''          . h.            [e              ~
Commissions                        NB-9947, Ark.-1133, "N* , "I" , "A"
[/                          Inspector's Signature                                                          National Board, State. Provuwe, and Endmemeras
        .v                              J.O. Elhott Date          S/3                                19 9V                                                                                                            i i
    ^
l
 
Page 1 (Front)
FORM NIS-2 OWNERS REPORT FOR REPAlRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI l
: 1. Owner AP&I/Entergy Operations, Inc                                              Date      03/22/94 Name Rt. 3, Box 137G, Russellville, AR 72801                                        Sheet        1              of            1                          .
Ahm                                                                                                                '
: 2. Plant        Arkansas Nuclear One                                              Unit            Two Rt. 3, Box 137G, Russellville, AR 72801                                          JO# 00905669 Address                                                    Repaar Orgamzataan P.O.No Job No etc.
: 3. Work Performed by AP&IJEntergy Operations, Inc                                  Type Code Symbol Stamp                N/A N=                                        Authorization No .-                  N/A Rt. 3. Box 137G Russellville, AR 72801                                          Expriation Date                      N/A
                                        ^**                                                                                                                  ,
: 4. Identification of System LPSI(2CCA-52) smn l '
: 5. (a) Applicable Construction Code                            19 77      Edition, S.79                Addenda, NA                        CodeCase (b) Applicable Edition of Section XI Utilized for Repairs of Replacements 19          86
: 6. Identification of Components Repairs or Replaced and Replacement Components i
ASME Code National                                        Repaired,              Stamped Name of                Name of              Manufacturer            Board          Other            Year        Replaced,              (yes Component                Manufacturer            Serial No.                No. Identification        Built      or Replacement          or No) 1" GLOBE                TARGET                2                  N/A            2SV-5001-1          1981-        REPAIRED -              YES VALVE                    ROCK
                                                                    "'^
\                                                                  "'^
        \                                                          N/A N/A
: 7. Description ofWork REMOVED & REWELDED BODY TO BONNET SEAL WELD
: 8. Tests Conducted              Hydrostatic l        l Pneumatic l    l Nominal Operating Pressure              l.
Other l    l Pressure NA                Psi      TestTemp NA                    F NOTE: Supplemental Sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
(12/82)                        This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 REPRINT 12/91
 
                                                        .          _            .    ,,      .m-  , _ ~ . , . .                              , _ .          s. m a
i j                                                                                                                                                          Page 1 (Back) i 1
)
i' FORM NIS-2 (Back) i i
: 9. Remarks NA
.f                                                                Apphcable Manufacture's Data Reports to be attached i
I i
i i                                                          CERTIFICATE OF COMPLIANCE j              We certify that the statements made in the report are correct and th                REPAIR                      carmns to the rules of the              ;
!  AShE Code, Section XI.                                                                  Repair or Replacerrect 1
Type Code Spnbol Stamp                                                                    N/A
,  Certificate ofAuthorization No.                        .N/A                  Expiration Date                                      N/A Signed                                              J' Date                        gb                            ,19 %
Owner or Odnei's Destanee. Tale                                                            s D.B. lanax - Manager, Engmeenng Programs 3
CERTIFICATE OF INSERVICE INSPECTION l  1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of          Arkansas                      and employed by            Factory Mutual Engineering Association                                        of i        Norwood. MA
!  in this Owners Report during the period                  10/20/92                      to gw  rNu    haveigted the componentsdescribed
                                                                                                                  '/('J, , t' +'//v/97                , and state that  ,
I  to the best of my knowledge and belief, the Owner has performed examinations 'and taken c'orrective' measures described in this                                      ,
Owners Report in accordance with the requirements of the AShE Code, Section XI.
;      'By signing this certificate neither the Inspector nor his employer makes any warranty, expressed orimplied, concerning the                                      l l  examinations and corrective measures described in this Owners Report,Furthermore, neither the Irupector nor his employer shall be liable in any manner for any personalinjury or property damage or a loss of any kind arising from or connected with this inspection.
1 k , d, [M                                                        Commissions                  NB-9947, Ark.-Il33, "N" , "I" , "A" 0'                                                                                                            National Board, State. Provira, and fadorsemeras
[/                          Inspector's Signature v                              J.O. Elhott l    Date        .5/"3                                19 9'/
i
 
Page 1 (Front)
FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI
: 1. Owner AP&IJEntergy Operations, Inc                                            Date      03/20/94 Name Rt. 3, Box 137G, Russelhille, AR 72801                                      Sheet        1              of        1 Aaar.
2 Plant          Arkansas Nuclear One                                            Unit            Two Rt. 3, Box 137G, Russellville, AR 72801                                      JO# 00906016 Addnm                                                      Repar Orgatuzatum P.O.No.. Job No.,etc.
: 3. Work Performed by AP&IJEntergy Operations, Inc                                Type Code Symbol Stamp                N/A Name                                    Authorization No                      N/A Rt. 3, Box 137G, Russelhille, AR 72801                                      Expriation Date                      N/A m
: 4. Identification of System HPSI (2CCA-24)
: 5. (a) Applicable Constmetion Code        sm m                19 71      Edition, S-71                Addenda, 1535-2                    Code Case (b) Applicable Edition of Section XI Utilized for Repairs of Replacements 19        86
: 6. Identification of Components Repairs or Replaced and Replacement Components ASME Code National                                    Repaired,              Stamped Name of                Name of            Manufacturer            Board        Other              Year        Replaced,              (yes Component              Manufacturer            Serial No.              No. Identification        Built    or Replacement            or No) 12" CHECK            ATWOOD                6-626                N/A        2SI-15C              1973        PARTS                    YES VALVE                  MORRILL                                                                                  REPLACEMENT N/A N/A N/A
                                                                      "'^
N
: 7. Description of Work REPLACED VALVE BONNET & DISC
: 8. Tests Conducted            Hydrostr.ic l )( l Pneumatic l        l Nominal Operating Pressure l          l Other l    l Pressure    2244        Psi    Test Temp 500+                  F NOTE: Supplemental Sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) informa-tion in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
l (12/82)                      This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 REPRINT 12/91 l
l
 
I l                                                                                                                                                  Page 1 (Back) i i
I l
l                                                                            FORM NIS-2 (Back) l
: 9. Remarks NEW BONNET S/N I,NEW DISC S/N 77842-2                                                                                                            ]
l                                                                          4,pi e r.amsom.a.p            =be  ~
l r
I l
CERTIFICATE OF COMPLIANCE l                    We certify that the statements made in the report are correct and this          REPLACEMENT confonns to the rules of the
(      ASME Code, Section XI.                                                                  Repaar or Replacernent                                          l l
I
      , Type Code Symbol Stamp                                                                    N/A                                                            l Certificate of Authonzation No.                  ,    N/A                  Expiration Date                            N/A Signed          .
8                                                        Date        ),,,, p gf                        ,19
                  # Ownpfar Owner's Damianse. Tale'                                              g D.B. Innax - Manager Engmeenng Programs                                        v                                                              :
t CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State                      1 or Province of -            Arkansas                  and employed by            Factory Mutual Engineering Association                        of      l Norwood. MA                                                                            w haveinspected the componentsdescribed                      l In this Owner's Report during the period                  10/20/92                    to 7/r/vv i'/t.'/?/ v/#F/M                  , and state that      l to the best of my knowledge and belief, the Owner has performed examinations and liken corrective measures described in this                              l Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed orimplied, concerning the examinations and corrective measures described in tids Own:r's Report.Furthermore, neither tie Inspector norhis employer shall be liable in any manner for any personalinjury or property damage or a loss of any kind arising from or connected with this inspection.
i i.
: 9. O. b                                                            Commissions            NB-9947, Ark.-l133. "N" , "I" , "A" g                            '
                                        , =- Sipanne J.O. Elhott Nananal Board, Rase, Pnmnce, and Endonernenu Date M3                                          19 9 Y 1
l
 
4 Pcge 1 (Front)
FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS .
As Required By The Provisions Of The ASME Code Section XI
: 1. Owner AP&I1Entergy Operations,Inc                                            Date      04/14/94 Name
!        Rt. 3, Box 137G, Russellville, AR 72801                                    Sheet        1                of        5 J
li                                          ^^***
: 2. Plant      Arkansas Nuclear One                                            Unit            Two j        Rt. 3, Box 137G, Russellville, AR 72801                                      JO# 00907826                                                      ;
Address                                            .
Rapnar Organizataan P.O.No Job No anc. .
: 3. Werk Performed by AP&IJEntergy Operations, Inc                              Type Code Symbol Stamp                N/A                          i Name.
;                                                                                    Authorization No '                    N/A
!        Rt. 3. Box 137G, Russellville, AR 72801                                    Expriation Date                        N/A 4                                            Addreu
!    4. Identification of System RCS (2CCA-13,14,15,16, & 2 EBB-7 & 2GCB-10 )                                                                            l 1
5, (a) Applicable Construction Code      Alsc                19 69      Edition, SUPP 1 & 2 Addenda, N/A                              Code Case l
j        (b) Applicable Edition of Section XI Utilized for Repairs of Replacements 19 J6 j    6. Identification of Components Repairs or Replaced and Replacement Components I
!                                                                                                                                              ASME 1                                                                                                                                                Code National                                      Repaired,            Stamped      !
i        Name of              Name of              Manufacturer          Board        Other              Year        . Replaced, .          (yes
}      Component            Manufactumr              Serial No.              No. Identification        Built    or Replacement            or No) i l      SNUBBER              PSA                    26149              N/A          2CCA-13-H4          E-          REPLACED                NO
]                                                                                                        1990                                            !
SNUBBER              LISEGA                  61258/02          N/A          2CCA-13-H4          1994-      REPLACEMENT            NO          I
:                                                                                                                                                        I I      SNUBBER              AD                      783                N/A          2CCA 14-H2          E          REPLACED                NO          l t                                                                                                      1990 SNUBBER              LISEGA                  61257/115          N/A          2CCA-14-H2          1994        REPLACEMENT            NO j      SNUBBER              AD                      762                N/A          2CCA-15-H9          E          REPLACED                NO
: j.                                                                                                      1990
: 7. D:scription ofWork REPLACED HYDRAULIC & MECHANICAL SNUBBERS PER LCP Hydrostatic l                        l Nominal Operating Pressure R g - 8. Tests Conducted                                  l Pneumatic l Other l      l Pressure    N/A        Psi    Test Temp N/A .                  F NOTE: Supplemental Sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x !I in., (2) informa-tion in items 1 through 6 on this repon is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
(12/82)                      This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 REPRINT 12/91
 
[      .
;                                                                                                                                                            Page 2 i          -
(Supple =*=t Sheet)
!                                  FORM NIS 2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS                                                                                  !
i                                          As Required By Me Provisions Of The ASME Code Section XI i    1. Owner AP&I1Entergy Operations,Inc                                                            Date    04/14/94
!                                                Nasas l          Rt. 3, Box 137G, Russellville, AR 72801                                                  Sheet      2                    of        5
?                                          um                                                                                                                            :
i t
: 2. Plant            Arkansas Nuclear One                                                      Unit          Two-                                                    j i          Rt. 3, Box 137G, Russellville, AR 72801                                                    JO# 00907826                                                        !
;                                          Mdrums                                                                Repar C..            P.O.No Jab No anc.
}    3. Work Perfonnedby AP&I/Entergy Operations,Inc                                                Type Code symbolStamp_                  N/A j                                            Nana'                                                  Authonzation No                        N/A I        Rt. 3. Box 137G, Russellville, AR 72801
                                            ^^*"
Expnation Date                          N/A i
: 4. Identification of System RCS-( 2CCA-13,14,15.16 & 2 EBB-7 & 2GCB-10 )
f 1
j    5. (a) Applicable Construction Code .. Assc                          19 69            Edition, SUPP 1 & 2            W=,          NA                    code Case j          (b) Applicable Edition of Section XI Utilized for Repairs of Replacements 19                    86                                                            ,
)    6. Identification of Components Repairs or Replaced and Replacement Components j                                                                                                                                                                ASME j                                                                                                                                                                Code l                                                                                    National                                        Repaired,              Stamped
!        Name of                Name of .            hd= 5 - -                        Board          Other              Year        Pa=M                    (yes Component                Manufacturer              Serial No.                        No. Idenhfication              Built    orReplacement l                                                                                                                                                              or No) i                                                                                                                                                                          ,
{    SNUBBER                  LISEGA                  61257/116                    N/A          2CCA-15-H9          1994          REPLACEMENT NO i                                                                                                                                                                          .
j    SNUBBER-                PSA                    30676                        N/A-          2CCA-15-H24        E              REPLACED                NO sann                                                !
l    SNUBBER                  LISEGA                  61293/65                      N/A          2CCA-15-H24        1994          REPLACEMENT NO i
SNUBBER                  AD                      1101                        N/A          2CCA-15-H26        E              REPLACED                NO l'                                                                                                                    inna i    SNUBBER                  LISEGA                  61257/117                    N/A          2CCA-15-H26        1994          REPLACEMENT NO i    SNUBBER                  AD                      876                          N/A          2CCA-15-H27        E .            REPLACED                NO
(                                                                                                                      i nne.                                              .
j    SNUBBER                  LISEGA                  61257/118                    N/A          2CCA-15-H27        1994            REPLACEMENT NO
!    SNUBBER                  PSA                    2766                          N/A          2CCA-15 H23 -      li              REPLACED                NO SNUBBER                  LISEGA                  61293/66                      N/A          2CCA-15-H29                        REPLACEMENT NO 1
1    SNUBBER                  AD                      761                          N/A          2CCA-15-H30        E              REPLACED                NO 1
SNUBBER
                                                                                                                      !a"^
LaSEGA                  61213/26                      N/A          2CCA-15-H30        1994            REPLACEMENT              NO l'    SNUBBER                  AD                      944                          N/A          2CCA-16-H1          E              REPLACED                NO
                                                                                                                      !aaa j    SNUBBER                  LISEGA                  61257/16                      N/A          2CCA-16-H1          1994            REPLACEMENT NO SNUBBER                  AD                      799-                          N/A          2CCA-16-H4        E              REPLACED                NO
,                                                                                                                    inon
;    SNUBBER                  LISEGA                  61257/14                      N/A          2CCA-16-H4          1994            REPLACEMENT NO-i.
1
 
Page 2
    '                                                        (Supplement Sheet)
FORM NIS-3 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI
: 1. Owner AP&I1Entergy Ooerations,Inc                                            Date      04/14/94 Name Rt. 3, Box 137G, Russellville, AR 72801                                  Sheet        3            of        5 us
: 2. Plant      Arkansas Nuclear One                                            Unit          Two Rt. 3, Box 137G, Russellville, AR 72801                                    .10# 00907826 M*                                                        ampar C..    - P.O.No Job No ek:,
: 3. Work Performed by AP&IJEntergy Operations, Inc                              Type Code Symbol Stamp          N/A Name Authorization No                N/A                          l Rt.3 Box 137G, Russellville, AR 72801                                    Expriation Date                  N/A Ana
: 4. Identification of System RCS (2CCA-13,14,15,16 & 2 EBB-7 & 2GCB-10 )
: 5. (a) Applicable Construction Code Atsc                      19 69      Edition, SUPP 1 & 2 Addenda, NA                        Code Case (b) Applicable Edition of Section XI Utilized for Repairs of Replacements 19      86
: 6. Identification of Components Repatrs or Replaced and Replacement Components l
ASME    l Code    4 National                            Repaired,              Stamped    <
Name of              Name of            Manufacturer              Board      Other Component            Manufacturer Year    P=lM                    (yes Serial No.              No. Identification        Built orRey20 = ^            ' or No)
SNUBBER              AD                  779                    N/A        2CCA-16-H3        E      REPLACED                NO SNUBBER              LISEGA              61213/27              N/A        2CCA-16-H3        khh    REPLACEMENT            NO        I SNUBBER              AD                  993                    N/A        2 EBB-7-H2        E      REPLACED                NO SNUBBER              LISEGA              61258/03              N/A        2 EBB-7-H2          hh    REPLACEMENT NO SNUBBER              PSA                  119                    N/A        2GCB-10-HS        E      REPLACED              NO SNUBBER              PSA                  30679                  N/A        2GCB-10-H5        khb    REPLACEMENT NO SNUBBER              P-M                  1804 (02)              N/A        2HS-SGB-E2        E        REPLACED              NO SNUBBER              PM                  1810 (06)              N/A        2HS-SGB-E2                REPLACEMENT NO SNUBBER              AD                  235                    N/A        2CCA-14-H5        E        REPLACED              NO SNUBBER              LISEGA                61257/126              N/A        2CCA-14-H5          hh    REPLACEMENT NO SNUBBER              AD                    237                    N/A        2CCA-15-H31      E        REPLACED              NO' SNUBBER              LISEGA                61257/128              N/A        2CCA-15-H31'      )hh    REPLACEMENT NO SNUBBER              AD                    885                    N/A        2CCA-15 -#ff E            REPLACED              NO SNUBBER              LISEGA                61257/129              N/A        2CCA-15-H34        hh    REPLACEMENT          NO SNUBBER              AD                    12                    N/A        2CCA-15-H36      E        REPLACED              NO inon                                      -
C e
i
 
              .- - - . - - - - -              ... .-                        .      -.      - . . . . .                . -              ~ -    -. _
!    .                                                                                                                                      Pap 2 i                                                                        - (Suppleasent Sheet)
!                                      FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS
!                                              As Required By The Provisions Of ne ASME Code Secties XI                                                  i i
l    1. Owner AP&I/Entergy Operations,Inc                                                Date          04/14/94 i                                                    N Rt. 3, Box 137G, Russellville, AR 72801                                          Sheet            4              of        5
{
4                                                um=
!, . 2. Plant Aa.nses Nuclear One                                                        Unit              Two
]        Rt. 3, Box 137G, Russellville, AR 72801                                          JO# 00907826                                                  l me==                                                        ma,an ors ===== r.o ham N=.=r              l
}
: 3. WorkPerformedby AP&I1Entergy Operations,Inc                                      Type Code symbolstamp                    N/A l                                                                                                                                                      ,
;                                                  N==                                    Authorization No                          N/A RL 3. Box 137G, Russellville, AR 72801                                          Expnation Date                            N/A
!                                                M*=                                                                                                    ,
j    4. Identification of symem RCS (2CCA-13,14,15.16 & 2HBB-7 & 2GCB-10 )
1 3
: 5. (s) Applicable Construction Code Asse              19 69    Edition, SUPP 1 & 2 AM*=ta. NA                          CodeCase 1
(b) Applicable Edition of Section XI Utihzed for Repairs of Reptar== =*= 19                86                                              ,
!    6. Identification of C---    ;----- -- - Repairs or RW and Py= - - =^ Car *                                                                      !
I 2                                                                                                                                              ASME Code i                                                                              National                                      Repaired,      Stamped
!        Name of                  Name of                Manshsuin              Board      Other                Year        Replaced,        (yes    -
i      Component                Manuf&.i-w                  Serial No.            No. Identification            Built    orReplacement      or No)
V l      SNUBBER                  LISEGA                    61258/54            N/A        2CCA-15-H36          1994-      REPLACEMENT      NO        i
!      SNUBBER                  AD                        720                N/A        2CCA-15-H39          E1910      REPLACED.        NO
!      SNUBBER                  LISEGA                    61257/130          N/A        2CCA-15-H39            1994      REPLACEMENT      NO        ,
SNUBBER                  AD                        991                N/A        2CCA-15-H41          E1990      REPLACED          NO f
SNUBBER                  LISEGA                    61258/55          N/A        2CCA-15-H41            1994      REPLACEMENT      NO SNUBBER                  AD                        411                N/A        2CCA-15-H44A          E1990      REPLACED          NO        ;
l
!      SNUBBER                  LISEGA                    61257/119          N/A-      2CCA-15-H44A          1994      REPLACEMENT NO j
1      SNUBBER                  AD                        1308              N/A        2CCA L.-:i44B        E1990      REPLACED          NO i
SNUBBER                  LISEGA                    61257/120          N/A        2CCA-15-H44B          1994      REPLACEMENT NO j
SNUBBER                  AD                        1406              N/A        2CCA-15-H45          E1990      REPLACED          NO l      SNUBBER                  LISEGA                    61257/124          N/A        2CCA 15-H45            1994      REPLACEMENT      NO a
;-      SNUBBER                  AD                            Pp4            N/A        2CCA 15-H50            E1990      REPLACED          NO SNUBBER                  LISEGA                    61258/56          N/A        2CCA-15-H50            1994      REPLACEMENT      NO l
1 SNUBBER                  AD                        417                N/A        2CCA-15-H53            E1990      REPLACED          NO ll I
SNUBBER                  LISEGA                    61257/121          N/A        2CCA-15-H53            1994      REPLACEMENT      NO i
4 a
I i                                                                                                                                                        l J
 
Page 2 i                                                                (Supplement Sheet) 4 FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI
: 1. Owner AP&I1Entergy Operations, Inc                                        Date        04/14/94 Name Rt. 3, Box 137G, Russellville, AR 72801                                Sheet    __
5            of          5 44*-
J  2. Plant      Arkansas Nuclear One                                          Unit            Two
;      Rt. 3, Box 137G, Russellville, AR 72801                                  JO# 00907826 Address                                                Rapaar Orgamzatace P.O.No Job No asc.
,  3. Work Performed by AP&IJEntergy Operations, Inc                            Type code symbol stamp              N/A N *=                                  Authorization No                    N/A j      Rt. 3 Box 137G Russellville, AR 72801                                  Expriation Date                      N/A
                                        ^d*"
i
: 4. Identification of System RCS (2CCA-13,14,15,16 & 2HBB-7 ' & 2GCB-10 )
AIsc                          Edition, SUPP 1 & 2 Addenda, NA
,  5. (a) Applicable Construction Code                          19 69                                                                Code case (b) Applicable Edition of Section XI Utilued for Repairs of Replacements 19    86
: 6. Identification of Components Repairs or Replaced and Replacement Components 4
AShE i
Code National                                Repaired,              Stamped i    Name of              Name of            M-remr                  Board      Other            Year      Replaced,              (yes Component            Manufacturer            Serial No.              No. Identification        Built    or Replacement          or No)
:  SNUBBER              AD                    997                  N/A      2CCA-15-H56        E1990      REPLACED                NO SNUBBER              LISEGA                61258/53            N/A      2CCA-15-H56        1994      REPLACEMENT            NO 1  SNUBBER              AD                    415                  N/A      2CCA-15-H60        E1990      REPLACED                NO SNUBBER              LISEGA                61257/122            N/A      2CCA-15-H60        1994      REPLACEhENT NO SNUBBER              AD                    943                  N/A      2CCA-16-H21        E1990      REPLACED                NO SNUBBER              LISEGA                61257/127            N/A      2CCA-16-H21        1994      REPLACEhENT NO 7
SNUBBER              AD                    1005                N/A      2CCA-16-H12        E1990    REPLACED                NO
]  SNUBBER              LISEGA                61257/123            N/A      2CCA-16-H12        .1994__ JEPLACEMENT NO I  SNUBBER              AD                    422                  N/A      2CCA-16-H16        E1990    REPLACED                NO h  SNUBBER              LISEGA                61257/03            N/A      2CCA-16-H16        1994      REPLACEMENT              NO N/A
        \                                                            N/A
            \      -
N/A x                                                  Na N                                              ""
 
I-
:                                                                                                                                                              Page 1 (Back) i l
J 3
l                                                                            FORM NIS-2 (Back) b
: 9. Remarks N/A                                                                                                                                                                  ,
Apphcable Manufacture's Data Reports to be anached l
t i
J 1
i d                                                                                                                                                                              .;
E 1                                                                                                                                                                                  ,
4
.                                                                CERTIFICATE OF CGMPLIANCE 1
We certify that the statements made in the report are correct and this -                    REPLACEMENT conforms to the rules of the
~
ASME Code, Section XI.                                                                            Repair or Replacement                                                        :
l                                                                                  .
3-l  Type Code Spnbol Stamp                                                                            N/A =                                                                      ;
4
)
Certificate of Authorization No.                                N/A                  Expiration Date                                      N/A Signed                    f,/ I o                            Date              4-Zb                                .,19 %
j              Owrdr or Owner's Desiance.Tille D.B. Lomax - Manager, Engineering Programs l
CERTIFICATE OF INSERVICE INSPECTION
!  I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State j  or Province of              Arkansas                        and employed by              Factory Mutual Engineering Association                                  of Norwood. MA                                                                                        at/ haveinspected the componentsdescribed
!  in this Owner's Report during the period                        10/20/92                        to #ver'//fd?            #
M/v/W                , and state that
:  to the best of my knowledge and belief, the Owner has performed examinations and'takeri corrective incasures described in this                                                ,
1  Owner's Report in accordance with the requirements of the ASME Code, Section XI.
!        By signing this certificate neither the Inspector nor his employer makes any warranty, expressed orimplied, concerning the 3  examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer                                                    !
j  shall be liable in any manner for any personalinjury or property damage or a loss of any kind arising from or ccnnected with this                                              !
;  inspection, l
  /f O. o. Eh                      Inspector's Sipiature Commissions                    us.9942. Ark..ii33. N                i , A-National Board, State. Provmoc, and Endorsements V                                  J.O. Elhott Date      S/3                                          19 9 at i
s G
v
 
i                                                                                                                                      Page 1 (Front) i                            FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS j                                    As Required By The Provisions Of The ASME Code Section XI 5
: 1. Owner AP&I/Entergy Operations, Inc                                            Date      04/12/94 Nasne 4
Rt. 3, Box 137G, Russellville, AR 72801 '                                    Sheet        1              of          1                              ,
addr                                                                                                              l
: 2. Plant - Arkansas Nuclear One                                                  Unit            Two-                                                  ,
;      Rt. 3, Box 137G, Russellville, AR 72801                                        JO# 00910284                                                        -
;                                        Address                                                    Repaar Orgamzatson P.O.No., Job NoA.
i  3. - Work Performed by AP&I1Entergy Operations, Inc                              Type code symbol Stamp                N/A                            f j                                          N=*    -
Authorization No .                  N/A l
Rt. 3. Box 137G, Russellville, AR 72801                                      Expriation Date                      N/A-
: 4. Identification of System LPSI(2CCA-15 )
{
: 5. (a) Applicable Constmetion Code        AIsc                19 69 Edition, SUPP 1 & 2 Addenda, NA                                  Code Case
]
(b) Applicable Edition of Section XI Utilized for Repairs of Replacements 19 - 86 j  6. Identification of Components Repairs or Replaced and Replacement Components i
~
ASME I
Code l                                                                        National                                    Repaired,          Stamped d-Name of              Name of                Manufacturer          Board      Other              Year        Replaced,          (yes Compnent              Manufacturer              Serial No.              No. Identification          Built      or Replacement        or No) l i                                                                                                                                                        ,
,'  COMPONENT            BECHTEL                  NA                N/A          2CCA-15-H30        E            REPAIRED            NO              I
:    SUPPORT                                                                                            1971 N/A                                                                                l l        N                                                            -
                                                                      "'^
l
!                \                                                    N/A j  7. Description ofWork MODIFIED SUPPORT
: 8. Tests Conducted            Hydrostatic l        l Pneumatic      l Nominal Operating Pressure          l Other l      l Pressure    NA          Psi      TestTemp NA                  F                                          l NOTE: Supplemental Sheets in form oflins, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) informa-
!      tion in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is l
recorded at the top of this form.
i                                                                                        .
i (12/82)                      This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 REPRINT 12/91
 
Page 1 (Back)
:                                                                                                                                                                        -j FORM NIS-2 (Back)
I
,  9. Remarks NA                                                                                                                                                          i
: j.                                                                  Applicable Manufacture 4 Data Reports to be anaded CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this                  REPAIR              conforms to the ndes of the ASME Code, Section XL                                                                    Repair or Replacement Type Code Symbol Stamp                                                                    N/A Certificate of Authorization No.                      N/A                    Expiration Date                                    N/A Signed            _
J,./ A,              '
                                                      . /) '
Date              4ff/3 -                          ,19 %
owner crbwner's Desianee. Titie D.B. Lomax - Manager, Engineenng Programs CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of          Arkansas                    and employed by              Factory Mutual Engineering Association                                    of Norwood, MA                                                                                rs' have i              ed  the componentsdescribed in this Owners Report during the period                  10/20/92                        to 7h h v M # &          7 p/ M M / M , and state that to the best of my knowledge and belief, the Owner has performed examinations 'and faken' corrective' measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed orimplied, concerning the                                      ,
examinations and corrective measures described inthis Owners Report.Furthermore, neither the Inspector norhis employer                                                ,
shall be liable in any manner for any personalinjury or property damage or a loss of any kind arising from or connected with this                                    ;
inspection.
I Q , O.        [jlM                                            Commissions                    NB-9947, Ark.-1133, "N" , "I" , "A" v                          lampector's signature J.O. Elliott National Board, State, Provmce, and Imdorsanans Date    5/3                                  19 9 4/
l
 
Page 1 (Front)
;                            FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI I
: 1. Owner AP&IJEntergy Operations, Inc                                            Date      04/04/94 Name Rt. 3, Box 137G, Russellville, AR 72801                                      Sheet        1              of        1 m e.
: 2. Plant        Arkansas Nuclear One                                              Unit            Two Rt. 3, Box 137G, Russellville, AR 72801                                        JO# 00910820 Addrums                                                    Repair Orgamzauon P.O.No.. Job No.,etc.
: 3. WorkPerformedby AP&IJEntergy Operations,Inc                                    Type Code Symbol Stamp                N/A N=                                      Authorization No                      N/A Rt. 3. Box 137G, Russellville, AR 72801                                      Expriation Date                      N/A Addreu
: 4. Identification of System RCS (2BCA-16 )
: 5. (a) Applicable Construction Code        SECT HI 19 77      Edition, S-79                Addenda, NA                      Code case (b) Applicable Edition of Section XI Utilized for Repairs of Replacements 19        86
: 6. Identification of Components Repairs or Replaced and Replacement Components ASME Code National                                    Repaired,              Stamped Name of              Name of              Manufacturer            Board        Other              Year        Replaced,              (yes Component            Manufacturer              Serial No.              No. Identification        Built    or Replacement            or No) 1" GLOBE            TARGET                  67                  N/A          2SV-4636-2          1990        REPAIRED                YES VALVE                ROCK
                                                                      "'^
  \~
N/A N/A N/A
: 7. Description ofWork REMOVED & REWELDED BODY TO BONNET SEAL WELD
: 8. Tests Conducted            Hydrostatic l        l Pneumatic l    l Nominal Operating Pressure l          l Other l      l Pressure NA              Psi    Test Temp NA                    F NOTE: Supplemental Sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
(12/82)                      This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 REPRINT 12/91
 
Page 1 (Back)
FORM NIS-2 (Back) 1 l
: 9. Remarks NA                                                                                                                                                    )
Apphcable Manufacture's Data Reports to be anached l
l CERTIFICATE OF COMPLIANCE                                                                                  l We certify that the statements made in the report are correct and this                REPAIR            conforms to the rules of the              l ASME Code, Section XI.                                                                    Repair or Replacement -                                              l Type Code Spnbol Stamp                                                                    N/A Certificate of Authorization No.                      N/A                    Expiration Date                                    N/A Signed                  2/ d [
Ownercobwners Desianee. THE '
Date              hl8
                                                                                                      /
                                                                                                                                      ,19 %
D.B. Lomax - Manager, Engmeenng Programs                                                                                                              :
CERTIFICATE OF INSERVICE INSPECTION -
I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State                              ,
or Province of          Arkansas                    and employed by              Factory Mutual Engineering Association                                of      I Norwood. MA                                                                              Aar haveinged the componentsdescribed                            !
in this Owner's Report during the period                10/20/92                      to 7Nev 1$hf , # #Ifdfv ,and state that
                                                                                                ~
l to the best of my knowledge and belief, the Owner has performed examinations and taken cbrrective medsures described in this
                                                                                                                                                                ]
Owner's Report in accordance with the requirements of the ASME Code, Section XI.                                                                                -
Bysigning thiscertificate neitherthe Inspectornorhis employer makes any warranty, expressed orimplied,concerningthe examinations and corrective measures described in this Owner's Report.Furthermore, neither the Inspector nor his employer sha!!be liableinany mannerforany personalinjury orproperty damageora lossofany kindarising fromorconnectedwith this inspection.
: 9. d. [                                                        Commiss'ons                    NB-9947, Ark.-l 133, "N" , "I" , "A" f                                  y                                                                National Board, State, Province, and Endorsements Date        8/3                              19 9 Y
 
Page 1 (Front)
FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI
: 1. Owner AP&I/Entergy Operations,Inc                                                                                            Date      04/04/94 Name Rt. 3. Box 137G, Russellville, AR 72801                                                                                    Sheet        1              of        I m
: 2. Plant        Arkansas Nuclear One                                                                                            Unit          Two Rt. 3, Box 137G, Russellville, AR 72801                                                                                    JO# 00910821 Mdras                                                                      Repas Organizaban P.O.No Job No etc.
: 3. Work Performed by AP&I1Entergy Operations,Inc                                                                                Type Code Symbol Stamp              N/A Name                                                Authorization No                    N/A Rt. 3 Box 137G, Russellville, AR 72801                                                                                      Expriation Date                    N/A m
: 4. Identification of System RCS (2BCA-16 )
: 5. (a) Applicable Construction Code                                              smm                            19 77    Edition, S-79              Addenda, NA                    Code Case (b) Applicable Edition of Section XI Utilized for Repairs of Replacements 19                                                      86
: 6. Identification of Components Repairs or Replaced and Replacement Components ASME Code National                                  Repaired,            Stamped Name of                Name of                                                              Manufacturer          Board      Other            Year        Replaced,            (yes Component                Manufacturer                                                              Serial No.            No. Identification        Built    or Replacement          or No) 1" GLOBE              TARGET                                                              70                  N/A        2SV-4636-1          1990      REPAIRED              YES VALVE                    ROCK N/A N                                                                                                          "'^
N/A
                                                                                                                          "'^
N
: 7. Description ofWork REMOVED & REWELDED BODY TO BONNET SEAL WELD 1
: 8. Tests Conducted              Hydrostatic l                                                        l Pneumatic l  l Nominal Operating Pressure l        l Other l                                        l Pressure NA                          Psi    TestTemp NA                  F NOTE: Supplemental Sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) informa-                                                            i l
tion in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is                                                                '
recorded at the top of this form.                                                                                                                                                              -
    . (12/82)                        This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 REPRINT 12/91
 
;                                                                                                                                                          Page 1 (Back) i
,                                                                          FORM NIS-2 (Back) l j  9. Remarks NA '                                                                                                                                                        j Apphcable Manufacture's Data Reports to be anached
{
j i
b i                                                                                                                                                                        j 1
i i'
CERTIFICATE OF COMPLIANCE We cenify that the statements made in the repon are correct and this                      REPAIR            conforms to the rules of the ASME Code, Section XI.                                                                        Repair or Replacement Tppe Code Symbol Stamp                                                                          N/A Certificate of Authorization No.                            N/A                  Expiration Date                                    N/A Signed                _ _je/ [                          /J                        Date                Mg6                                ,19 %
Owner or 06ner's Dessanee. Title                                                              '
D.B. Lomax - Manager, Engineermg Programs CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State er Province of                Arkansas                  and employed by              Factory Mutual Engineering Association                                of Norwood, MA w - have iy'ed the components described in this Owner's Report during the period                      10/20/92                      to # # #
                                                                                                        ~
4dT, , f            #/v/W , and state that to the best of my knowledge and belief, the Owner has performed examinations and tafen corrective meas'ures described in this                                        l Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed orimplied, concerning the examinations and corrective measures described inthis Owner's Report.Furthermore, neither the Inspector norhis employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
: 1. O. -[lf d                                                      Commissions                  NB-9947 Ark.-1133, "N" , "1" , "A" g                            inspector s signature                                                    nation. soard, state, Province, and Endorsernenis J.O. Elhott -
Date          S/.3                                  19 W
 
Page 1 (Front)
FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASM.E Code Section XI
: 1. Owner- AP&llEntergy Operations,Inc                                          Date      M/05/94 Rt. 3, Box 137G, Russellville, AR 72801                                    Sheet        1                of        I us
: 2. Plant      Arkansas Nuclear One                                            Unit            Two Rt. 3, Box 137G, Russellville, AR 72801                                      JO# 00908358 M&.as                                                    Repair Organamuon P.O.No., Job No.,etc.
: 3. WorkPerformedby AP&IJEntergy Operations,Inc                                  Type Code Symbol Stamp                N/A Nan =                                  Authorization No                      N/A Rt. 3. Box 137G, Russellville, AR 72801                                    Expriation Date N/A us
: 4. Identification of System LPSI(2CCA-22 )
: 5. (a) Applicable Construction Code      sum                  19 71      Edition, S-72                Addenda, NA                      code case (b) Applicable Edition of Section XI Utilized for Repairs of Replacements .19      86
: 6. Identification of Components Repairs or Replaced and Replacement Components ASME Code National                                    Repaired,              Stamped Name of              Name of              Manufacturer            Board      Other              Year        Replaced,              (yes Component            Manufacturer            Serial No.              No. Identification        Built    or Replacement            or No) 6" CHECK              ANCHOR                IN 102              N/A        2SI-14A              1975        REPLACED                YES VALVE                DARLING 6" CHECK              ANCHOR                EB-721-1-1          N/A        2SI-14A              1991        REPLACEMENT YES VALVE                DARLING N/A N/A
: 7. Description ofWork CUT-OUT                    REPLACED VALVE
: 8. Tests Conducted            Hydrostatic l )( l Pneumatic l        l Nominal Operating Pressure l          l Other l    l Pressure 2937            Psi    Test Temp AMB                  F NOTE: Supplemental Sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) informa-tion in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
(12/82)                      This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 REPRINT 12/91
 
l Page1(Back)
FORM NIS-2 (Back)                                                                              .
  ' 9. Remarks NPV-I MANUFACACTURERS DATA REPORT FOR REPLACEMENT VALVE ATTACHED Apphcalde Manufacture's Data Repons to be enached l
l l
i CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this          REPLACEMENT conforms to the rules of the ASME Code, Section XI.                                                                    Repair or Replacement Type Code Symbol Stamp                                                                    N/A .
Certificate of Authorization No.                        N/A                Expiration Date                                    N/A Signed                      8 Owner or Gwner's Desumea. Title
                                                .bQ                                Date            kl6                                  ,19 94 D.B. Lomax - Manager. Engineering Programs CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of              Arkansas                  and employed by            Factory Mutual Engineering Association                                of Norwood. MA                                                                              up haveinspected the componentsdescribed in this Owner's Report during the period                  10/70/92                      to 7h h v Y # G h ' FIfv/ # , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken co'rrective 'meaIsures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Ownefs Report.Furthermore,' neither the Inspector nor his employer shall be liable in any manner for any personalinjury or property damage or a loss of any kind arising from or connected with this l~    inspection.
k . C.      [M          Inspector's Signature Commissions                NB-9947 Ark.-l133, "N" , "1" , "A" National Board, State. Province, and Endorsernents
      //
V                                J.O. Elliott Date        S/.3                                19 'l Y I
l
!~
 
9, A/M 6/n/e I f
a      s                                              !g
* CORRECTED COPY 6/10/91                                  ygy g/)  ~
REPORT POR NUCLEAA PUGAPG OR VALYRStjgf 7yjij /
PORM NPV 1 CERTIFICATE HOLD l                              As Reedred by the 7.R _':                    of the ASME Code. Seeten lit. DMelon 1 of
!                                                                                                                              PS.
l@
i
            ,, w w                      w Anchor / Darling Valve Co. 701 First Street, W1111aasport, PA 17701 waseowesseneweonomemasem 72901 i            a, u.sene ,ess. Enterav Doerations. Inc. . Route                                      3. Russellville.
wp.e-a        o=en          AA i
c    weme
: 3. t e een.r m Arkansas Nuclear One. Russe 11vitie. AA 72901                                                                    -
;                                                                                                .e see,s e i
TOC                                  it9023335          %,            A        ,          4/A l            4. usesi me s.tw me = tvo.
I                                                        1971                      Sumaner 1972                        1              *WA 1516-1
: a. Asus case sessen m. oeveene i:
tease            sCees Case es.
epete"1                      hessade seus                                                        -
6'                  % ,,,,        6*
2 e,  p.,, , .          Valve            we
: 7. m aw, $A351-CF8M                      ,,,,,, $A!40 316                        es,n $A351-CF8M              hs - SA453-660s l                                                                                                                            Ruts - $A194-8M i
w                      w                                  w                          w                        W l
non                                ew,                        amene                      ota
.                    em                                                                                                                serned D eMi                              Sereof                      Sests
).                  Heimer's see,                                sen,                        sen.                      No.
)                  Sorted No.
b/A                              V5gg'                          y                      U5536        J C lb72'.-L-L                                                            U55Z;.'                          10                    U5837 b /A
;            [b7 2. ,- a-2                                                                                                                                      _
1 l
e m e w mas, isomene, w ee.e e. .=, no e es sii see is en                          1t, cm me.=e    m e== 1 e.nen a a si.e      e me en    case w a nunnes en e.m eaa. sa eeen an m m au                    e e em a eer es ease m menses a se == se em smaa.
(1&SW                  Thee tena S$efe7: me, no enten ed treme see Onser Dest ASIS,23 Leur tube. See sma, seereons. NJ 07001-430s.
O i?O G G G 9 2 . O : t4 E
 
                                                                                                                                                                                        # 4 4                                                                              PORA4 NPV 1 (booki Gasket Retainer, SA240-316; Hinge Pin Covers SA182-F316 i
                                                                                                                              ,,.neu,e esse 1500        -m 650        ., , ,*e 2580                  _,e e % een,es,.                                      e,
_ _ =e      -
3600                _ ,w a too.,
l  so. ces e w -                                                                                                          3600
                                                                                                                                                                            - ,e i
'                                                  6425          ,et m en,,,ew                      - _
n , n. _ u .,
commcAnon or osesen AI                                    4557 mee, as.
Larry 0. Youn0                              P.s. sm
    %                                    e,,,,,,NonaldFarrel1                                            _ p.g. so.          PA                    - g no. .03H 1'4 -
    % % ,,n,n,, g _
cernpicAfr Or swoe conspuAsocs we e.wy v    v. ennem ee mees in we ree-i ne uma and om v* rwn, = ** owde== = ** nda 8w esasewe
    # ** " *******" "" "                                          ''                                                        Eustres 4/15/92                  -
N1712 N Coneneses of hoherenedan
* j        --
m.,
AACh0r/Darl100 ValVG COEpany g,,og N*O9 9/ V:
e_-
One                                                                  . _ ,s ceRTwecATE or SMor seestCThost end
: i. the unsereigned, holene a vend esmmiesten                                                                leeued
                                                                                                        -- wid amoneyar      w ''- b, the Neuenal Seerd of Seder and Press
      ,,e go,e upsgeme se _                              Penn<v1vania
_ ne,,e w v. ,,,,,, . ,,se. me ess a wee ones asses en e,      Soston. Mass.
      /-ti-7/dL A/90 , is fff.,,,, ,w ees. == . ww men et my nne wee, and naaet, we connenes Meneer amo eenovuned this pump, er wesve. In eesseeense wem ww Asses Cees. Seseen W. Dedenen 1.
av verde ses cervasses, noemer we innesener nw his                                                                        s amedeyw meneer ser            say wenway. aomen esmoonwn desamed m we o es me, rt. rweismore noen v. meevener nor we one ever enes ne mome e new    any und arianne two w eennemed wem ode messenen, any e=eens % e presen, oss Al- h @ L
                                                                  .- 4                          hve f m"*?sra;sylvania        * ''d '"*"*""""f392          "'" ' 8"o. as W Che? eV T U [ /
                                                                                                /
se e,e,.
m ew - eew o.w sa==.oe m
                                                                                                                                                                                            .+
                                                                                                                                                                                                  . g
_ _ - _ _ _ _ . _ _ _ _ _ _ . . _          __m    __ __        _ _ _ _ - -                      -- ___        _ _ _ _ _ _ _ _
 
1 Page 1 (Front)
FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI 1
: 1. Owner AP&UEntergy Operations, Inc                                            Date      04/08/94 Name f      Rt. 3. Box 137G, Russellville, AR 72801                                    Sheet        1              of        1
!                                          *=
: 2. Plant      Arkansas Nuclear One                                            Unit            Two Rt. 3, Box 137G, Russellville, AR 72801                                      JO# 00911983 g                                          Address                                                  Repaar Orgamzaban P.O.No., Job No etc.
: 3. Work Performed by AP&UEntergy Operations, Inc                                Type code symbol Stamp              N/A N=                                    Authorization No                    N/A
;      Rt. 3. Box 137G, Russellville, AR 72801                                    Expriation Date                      N/A i                                          Addre=
l  4. Identification of System RCS (2CCA-17 )
: 5. (a) Applicable Construction Code        SECTnl 19 77      Edition, S-79              Addenda, NA                      Code case (b) Applicable Edition of Section XI Utilized for Repairs of Replacements 19      86
: 6. Identification of Components Repairs or Replaced and Replacement Components
;                                                                                                                                          ASME Code
.                                                                      National                                    Repaired,              Stamped Name of              Name of                Manufacturer          Board      Other              Year        Replaced,              (yes Component            Manufacturer              Serial No.              No. Identification        Built    or Replacement          or No) i
. 1" GLOBE            TARGET                  20                N/A        2SV-4668-2          1980        REPLACED                YES 4
VALVE                ROCK 1" GLOBE            TARGET                  83                N/A        2SV-4668-2          1992        REPLACEMENT YES
:    VALVE                ROCK N/A N                                                  "'^
: 7. Description of Work CUT-OUT                    AND REPLACED VALVE
: 8. Tests Conducted            Hydrostatic l        l Pneumatic l  l Nominal Operating Pressure l          l Other l      l Pressure NA            Psi    Test Temp NA                    F NOTE: Supplemental Sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) informa-I      tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
;  (12/82)                      This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 REPRINT 12/91
 
l l
Page1(Back) l i
FORM NIS-2 (Back) l
: 9. Remarks NPV-1 MANUFACTURES DATA REPORT FOR REPLACEMENT VALVE ATTACHED Applicable Manufacture's Data Reports to be attached                                              ;
l CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this          REPLACEMENT conforms to the rules of the                            l ASME Code, Section XI.                                                                      Repair or Replacement Type Code Symbol Stamp                                                                      ~N/A Certificate of Authorization No.                        N/A                    Expiration Date                                      N/A                            !
Signed                          8d Owner or Owiiers Desianee. Titic -
J '
Date              klb                                    ,19 %
D.B. Lomax - Manager, Ergineering Programs                                                                                                              ,
CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of              Arkansas                  and employed by              Factory Mutual Engineering Association                                of Norwood, MA                                                                              Aar ha einspected the componentsdesenkt in this Owner's Report during the period                  10/20/92                        to 7/##V ,,y/.',-If M/V/99 , and state that l    to the best of my knowledge and belief, the Owner has performed examinations'and (aken' corrective' medsures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed orimplied, concerning the examinations and corrective measures described inthis Owner's Report.Furthermore, neither the Inspector norhis employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
i l
Q.C. [ M                                                          Commissions                  NB-9947, Ark.-1133, "N" , "I" , "A" 6                              Inspectors Sipature J.O. Elliott -
National Board, State. Province, and E.ndoraenwnsa Date          S/3                              19C f'/
l l
l
 
l                                                                                                                                                                            l l
j
\                                                                                                                                                      $$V-//blS-A          l l                                                                                                                                                      % 83                \
;e                FORM NPV 1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES
* i                                    As Required by the Provisions of the ASME Code, Section lil, Div.1
: 1. Manufactured and cortified by Target Rock Corp.; 1966E Broadhollow Rd; E. Farmingdale, NY 11735 (name and address of N Cerftficate Holderp                              ,
: 2. Manufactured for            Entergy Operations Inc.; Russellville, Arkansas 72801 Iname and address of Purchaser or Owner)
Arkansas Nuclear One; Russellville, Arkansas 72801
: 3. Location of installation (name and address)
[. Model No., Series No., or Type                80E-001          Drawing
                                                                                                  #              Rev.                        CRN
: 5. ASME Code Section m:
1977                          S 1979                            1                            N/A Edition                  Addenda date                      Class                      Code Case no.
: 6. Pump or valve                Va1ve              Nominal inlet size 1
Outlet size tin.)                                    Im.)
: 7. Material: Body        SA-182 F316L g,nn,,SA-479 316                              g;,g SA-564 GR 630 %y                      SA-479 316 Indicator Tube (a)                          (b)                            (c)                          id)                              (el Cert.                        Nat'l                          Body                          Bonnet                            Disk          Indicator Holder's                      Board                          Serial                        Serial                          Serial            Tube Serial No.                      No.                            No.                            No.                            No.            Serial No.
75                          N/A                        5770                            3514                            2049              4099 76                          N/A                          5763                          3584                            2043              4143 l
77                          N/A                          5771                          3770                            1965              4057 78                          N/A                          5766                            3552                          2014              4193 79                          N/A                          5764                          3631                            1963              4124 80                          N/A                          3782                          3549                            2010              4187 81                          N/A                          5783                            3775                          1960              4072 I                      82                          N/A                          5759                            3640                          2047              4178
                                      ~
l      [                83                          N/A            ~_          5760                            3510                          2001          -~
4105) 3560                            2004              4233 84                          N/A 1                        5781 N/A                          N/A                          N/A                            N/A                            N/A                N/A s
          *SuDDiementalinformahon en the form of hsts, sketches, or drawings may be used provided (1) stre es 8'4 x 11, (2) snformation en stems 1 through 4 on this Data ReDort is included on each sheet, (3) each sheet is numoered and the number of sheets is recorded at the top of this form I
16/8 5)                                      tNs form IE00037 may be obta.ned from the Order Dept . ASME,345 E 47th St . New York. N Y.10017 l- ,
 
l l
FORM NPV-1 (bock)
Mfr. Serial No.                                    )
: 8. Remarks 1
00        ,,;            700                . p ,,      y,,,,  ,,,,,,,,,,,,,
                                                                                                                                        @                ,33
: 9. Design conditions (pressures                      tiemperaturel
: 10. Cold working pressure                                  psi at 100'F
: 11. Hydrostatic test            b            psi Temp.        A M ent            ,,,__.F  Disk differential test pressure                        psi CERTIFICATION OF DESIGN                                                                                          .
Larry Young                              Prof. Eng. state Arkansas          Reg.No.
Design Specification certified by Design Report certified by            Steven Karidas                                  Prof. Eng. state      NY              g,g go, 0%00 i
CERTIFICATE OF SHOP COMPLIANCE We certify that the statements made in this report are correct and that this pump or valve conforms to the rules for construction of the ASME Code, Section Ill.
* N Certificate of Authorization No                                                                          Expires Date                    Name Target Rock Corporation                                Signed                -        /#bb (N Certificate Holder)                                    E. Bajed(9ntoseector, Q. A.
I
                                                    \
CERTIFICATE OF SHOP INSPECTION selIns
: 1. the undersigned, holding c valid commission issued by the National Board of Boiler                    Come  andrcia Pressure l VgMon]ctors ns. agdo.
the State or Province of        New York                                            and employed by of Boston, Mass.                                              have inspected the pump, or volve, described in this Data Report on
                ,I[M                  19f8 and state that to the best of my knowledge and belief, the N Certificate Holder has constructed this pump, of valve, in accordance with the ASME Code, Section Ill.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the                                        l equipment desenbed in this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any rnanner for any personal injury or roperty damage or a loss of any kind arising from or connected with this inspection.
Date                                -1
                      /                                                                    N.Y. STATE COMMISSION NO. 2288 ALSO COMMISSIONED IN PENN., OHIO & CONN.
ommissions
                                              # _                                                (Nat'l 8d., Und. endorsemental State. Prov. and No.)
Unopector)
(1) For manually operated velves only.
                                                                                                            -    ._.        -                                ,- _m
 
l Page 1 (Front) 3 FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS j                                    As Required By The Provisions Of The ASME Code Section XI 4
: 1. Owner AP&IJEntergy Operations,Inc                                              Date      04/12/94 i                                              Name
!      Rt. 3, Box 137G, Russellville, AR 72801                                        Sheet        1              of        1 Addrem
: 2. Plant        Arkansas Nuclear One                                              Unit            Two j      Rt. 3, Box 137G, Russellville, AR 72801                                          JO# 00912145 j                                            Address                                                  Repair Organga6cn P.O.No Job No etc.
: 3. Work Performed by AP&IJEntergy Operations, Inc                                  Type Code Symbol Stamp              N/A N=                                      Authorization No                    N/A i      Rt. 3, Box 137G, Russellville, AR 72801                                        Expriation Date                    N/A Addres
: 4. Identification of System RCS (2CCA-15 & 16 )
: 5. (a) Applicable Construction Code Aisc                          19 69      Edition, SUPP 1 & 2 Addenda, NA                            Code case (b) Applicable Edition of Section XI Utilized for Repairs of Replacements 19          86
;  6. Identification of Components Repairs or Replaced and Replacement Components I
1 a
j                                                                                                                                          ASME Code i                                                                          National                                  Repaired,            Stamped
:      Name of                Name of                Manufacturer            Board      Other            Year        Replaced,            (yes 1
Component              Manufacturer              Serial No.              No. Identification        Built    or Replacement        or No) 4 HYDRAULIC              LISIGA                  61257              N/A          2CCA-15-H44 A      1994        REPAIRED              NO i    SNUBBER                                        119 & 120                      2CCA-15-H44B i    HYDRAULIC              LISEGA 61257-            N/A          2CCA-15-H53        1994        REPAIRED              NO SNUBBER                                        121 i    HYDRAULIC              LISEGA 61257-122          N/A          2CCA-15-H60        1994        REPAIRED              NO SNUBBER
;    HYDRAULIC              LISEGA                  61257-123          N/A          2CCA-16-H12        1994        REPAIRED              NO 4    SNUBBER N/A
: 7. Description of Work WELDED EXTENSION PIECES TO SNUBBERS
: 8. Tests Conducted            Hydrostatic l          l Pneumatic l    l Nominal Operating Pressure l        l Other l        l Pressure NA              Psi    Test Temp NA                  F 4
NOTE: Supplemental Sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 1I in., (2) informa-tion in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
(12/32)                      This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017
.                                                                                                                              REPRINT 12/91
 
I Page1(Back) l FORM NIS-2 (Back)
: 9. Remarks NA                                                                                                                                                    l Applicable Manufactmet Data Reports to be attactead i
l CERTIFICATE OF COMPLIANCE -                                                                              l We certify that the statements made in the report are correct and this                  REPAIR                conforms to the rules of the ASME Code, Section XL                                                                    Repair or Replacement -
i T3pe Code Symbol Stamp                                                                    N/A Cettificate ofAuthonzation No.                          N/A'                  Expiration Date .                                N/A Signed                  8[
Owner er owner % Damianse. Tale . /
J                              Date        dff6
                                                                                                                                                        ,19 94 j
D.B. Lomax - Manager, Engmeenng Programs i
CERTIFICATE OF INSERVICE INSPECTION                                                                            '
I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of          Arkansas                      and employed by              Factory Mutual Engineering Association                              of Norwaod. MA                                                                                4W ' have inspected the components described in this Owner's Report during the period                  10/20/92                      to 7/7 M 8 _ Y f ;' 9 d 9 /9 / , and state that to the best of my knowledge and belief, the Owner has performed examinations and faken' corrective' measures da.TuM in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.                                      . .
By signing this certificate neither the inspector nor his employer makes any warranty, expressed orimplied, concerning the examinations and corrective measures described in this Owner's Report.Furthermore, neither the Inspector nor his employer                                      !
shall be liable in any manner for any personalinjury or property damage or a loss of any kind arising from or connected with this inspection.
i 9,C. b M                                                            Commissions                NB-9947 Ark.-l133, "N" , "1" , "A" 6                            Inspector's Signature
: 10. Elhott Natsonal Board, State. Pronnce, and Endarnemeras Date          S/3                                19 9 V i
 
i Attachment to 2CAN079403 l                                  <
1 1
1 l
                                  \
i 1
l                                !
1 I                                t l
NIS-2 FORMS CLASS-2
[
i i
l l
I 4
l l
 
l                                                                                                                                                      l
!                                                                                                                                        Page 1 (Front) l                            FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI
: 1. Owner AP&IJEntergy Operations,Inc                                            Date        11/03/92 Name Rt. 3. Box 137G, Russellville, AR 72801                                      Sheet        1              of          I i
Ahm
: 2. Plant        Arkansas Nuclear One                                            Unit            Two Rt. 3, Box 137G, Russellville, AR 72801                                      JO# 00813666 Address                                                  Repair Organnatasi P.O.No., Job No etc.
: 3. Work Performed by AP&IJEntergy Operations, Inc                                Type Code Symbol stamp                N/A
                                                            ~
Name                                    Authorization No                      N/A Rt. 3. Box 137G, Russellville, AR 72801                                      Expriation Date                      N/A
                                          ^*"
: 4. Identification of System S.G.S (2DBB-8)
: 5. (a) Applicable Construction Code sm.m                      19 71      Edition, W-72              Addenda, 1516                      Code Case (b) Applicable Edition of Section XI Utilized for Repairs of Replacements 19        86
: 6. Identification of Components Repairs or Replaced and Replacement Components ASME Code National                                    Repaired,              Stamped Name of              Name of              Manufacturer            Board        Other            Year        Replaced,              (yes Component            Manufacturer            Serial No.              No. Identification        Built    or Replacement            or No)
C GATE                ANCHOR                2N-334              N/A          2CV-1066-1          1974        PART                    YES VALVE                DARLING                                                                                  REPLACEMENT N/A
                                                                      "'^
N                                                          N/A N/A
: 7. Description ofWork REPLACED VALVE BONNET ASSEMBLY
: 8. Tests Conducted            Hydrostatic l        l Pneumatic l    l Nominal Operating Pressure y                                                  ;
Other l    l Pressure 2160            Psi    Test Temp 100                  F l
NOTE: Supplemental Sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) informa-              i tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
(12/82)                      This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 REPRINT 12/91
 
Page1(Back) l FORM NIS-2 (Back)                                                                            j i
i
: 9. Remarks N-2 MANUFACTURERS DATA REPORT NOT AVAILABLE                                                                                                              !
Applicable Manufacturn Data Rapons e be ansched i
l P
CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and th        REPLACEMENT caforms to the rules of the ASME Code, Section XI.                                                                    Repair or Replacement P
Type Code Spnbol Stamp                                                                    N/A Certificate ofAuthorization No.                        N/A                  Expiration Date                                  N/A                              .
i Signed                    II owner or ou Desiann.ni.
J' Date          3-t                                ,19 $ $.
D.B. Immax - Manager, Engmeenng Programs 1
CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of          Arkansas                      and employed by            ' Factory Mutual Engineering Association                        ' of Norwood. MA                                                                              m have                  ed the componentsdescribed in this Owners Report during the period                  10/20/92                      to 7/7hv Y,p?d# M/v/fv ,and statethat to the best of my knowledge and belief, the Owner has performed examinations and taken corrective ineasures described in this Onefs Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neitherthe Inspector norhis employer makes any warranty, expressed orimplied,concerningthe examinations and corrective measures described in this Owners Report.Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personalinjury or property damage or a loss of any kind arising from or connected with this inspection.
        .      . bO                                                Commissions              NB-9947. Ark.-l 13 3, "N" , "I" , "A"
    //                          Inspector's Sipature                                                  National Board, State, Pronnce, and F '--
v                              J.O. Elliott Date        S/.3                              19 9s/
                                                                                                                                                                    )
 
Page 1 (Front)
FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI -
: 1. Owner AP&I1Entergy Operations, Inc                                              Date          03/16/93 Nams Rt. 3. Box 137G, Russellville, AR 72801                                        Sheet        1-                of          1 Am.
: 2. Plant        Arkansas Nuclear One                                              Unit          -Two                                                    .
1 Rt. 3, Box 137G, Russellville, AR 72801                                        JO# 00854640                                                          !
Address                                                      Repair Organazaban P.O.No,, Job No., sic.
: 3. Work Performed by AP&I/Entergy Operations,Inc                                    Type Code symbol Stamp                    N/A Nan
* Authorization No                          N/A Rt. 3. Box 137G, Russellville, AR 72801                                        Expriation Date                          N/A Am.s
: 4. IdentificationofSystem LPSI(2GCB)
: 5. (a) Applicable Construction Code        su m                19 71        Edition, S-72                Addenda, NA                        code Case (b) Applicable Edition of Section XI Utilized for Repairs of Replacements 19          86
: 6. Identification of Components Repairs or Replaced and Replacement Components
                                                                                                                                                        ~ASME        1 Code National                                        Repaired,            Stamped Name of                Name of            Manufacturer.            Board        Other              Year            Replaced,            (yes Component              Manufacturer            Serial No.                No. Identification        Built          or Replacement        or No) l'' GATE              BORG-                  920-                N/A            2SI-1036            1973            REPAIRED              YES VALVE                  WARNER                                                                                                                            1
                                                                            "'^
        \                                                                  N/A N/A                                                                                    I
                                                                            "'^
N
: 7. Description ofWork REMOVED & REWELDED BODY TO_ BONNET SEAL WELD
: 8. Tests Conducted              Hydrostatic l        l Pneumatic- l    l Nominal Operating Pressure l          l Other l    l Pressure NA                Psi      Test Temp ' NA                  F NOTE: Supplemental Sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) informa-tion in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is l              recorded at the top of this form.
l (12/82)                        This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 REPRINT 12/91 l                                ..                                          -__                _                            . .          _                    _
 
Page1(Back).
t                                                                                                                                                                        -r l                                                                        FORM NIS-2 (Back)
: 9. Remarks NA                                                                                                                                                      j Appucable Manuractwe's Data Repwts to be anached f
l l
l CERTIFICATE OF COMPLIANCE.
We certify that the statements made in the report are correct and th                - REPAIR                conforms to the rules of the ASkE Code, Section XI.                                                                    Repair or Replacement I
Type Code Symbol Stamp                                                                    N/A                                                                      l t                                                                                                                                                                          i t                                                                -                                                                                                        I Certificate of Authonzation No.                        N/A                  - Expiration Date                                  , N/A                              j Signed                  df I,[                                                Date'          S=2                                    ,19 % -
ownpf or owners Desianee.Tnie '
D.B. Immax - Manager. Engineering Programs CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of            Arkansas                  and employed by              Factory Mutual Engineering Association .                              of Norwood, MA                                                                              der havginspected the components described in this Owner's Report during the period                10/20/92                      to 7N#/ Yi fe i / MW/9/                              , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective' measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed orimplied, concerning the examinations and corrective measures described in this Owner's Report.Furthermore,- neither the Inspector nor his employer shall be liable in any manner for any personalinjury or property damage or a loss of any kind arising from or connected with this inspection.
i Q. O.        [ /4                                                  Commissions                    NB-9947, Ark.-1133 "N" , "I" , "A" g                            inspectors signauwe                                                    , Nanonal Board, State, Province, and Endorsenmes J.O. Elhott Date      8/3                                19 9Y-
 
;                                                                                                                                              Page 1 (Front) 1                              FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS l                                      As Required By The Provisions Of The ASME Code Section XI
; 1. Owner AP&IJEntergy Operations, Inc                                                  Date      04/12/94 j                                                Name
{      Rt. 3, Box 137G, Russellville, AR 72801                                            Sheet        1                of          1
.l                                              Addras j 2. Plant        Arkansas Nuclear One                                                  Unit          Two I      Rt. 3, Box 137G, Russellville, AR 72801                                            JO# 00U7863 l                                              Addras                                                    Repaar Orgamzauan P.O.No., Job No.,sec.
l 3. Work Performed by AP&IJEntergy Operations,Inc                                        Type Code Symbol Stamp                N/A                            j N=
i                                                                                        Authorization No                      N/A l      Rt. 3. Box 137G, Rnssellville, AR 72801                                          Expriation Date                      N/A
:                                              Addras i
j 4. Identification of System MS (2 EBB-18 )
1
; 5. (a) Applicable Construction Code 8NH                                19 74    Edition. S-75                Addenda, NA                      code Case i      (b) Applicable Edition of Section XI Utilized for Repairs of Replacements 19              86                                                        .
: 6. Identification of Components Repairs or Replaced and Replacement Components 1
i.
l                                                                                                                                                  ASME j                                                                                                                                                    Code National                                      Repaired,            Stamped Name of              Name of                  Manufacturer            Board        Other              Year        Replaced,            (yes Component            Manufacturer                  Serial No.                No. Identification          Built    or Replacement          or No)      ;
j                                                                                                                                                              !
l    1" GATE              HENRY                      58-214782            N/A        2MS-55                E          REPLACED              YES I
VALVE                VOGT                                                                                1980 s    1"OVIE              IENRY                      52-215017            N/A        2MS-55                1983        REPLACEMENT YES f    VALVE                VOGT
{                N                                                        "'^
N/A l 7. Description ofWork CUT-OUT & REPLACED VALVE
: 8. Tests Conducted            Hydrostatic l            l Pneumatic l    l Nominal Operating Pressure l          l Other l          l Pressure NA              Psi    Test Temp NA                    F s
NOTE: Supplemental Sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) informa-
;      tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is                        )
l        recorded at the top of this form.                                                                                                                      I i
(12/82)                      This Form (E00030) may be obtained from the Order Dept., AShE,345 E. 47th St., New York, N.Y.10017 j                                                                                                                                    REPRINT 12/91
 
Page 1 (Back)
FORM NIS-2 (Back) l
: 9. Remarks appiabi. wanur. cam tw a.p== = b. -
i NPV-1 MANUFACTURERS DATA REPORT FOR REPLACEMENT VALVE ATTACHED l
l CERTIFICATE OF COMPLIANCE                                                                  I
                  - We certify that the statements made in the repoit are correct and this          REPLACEMENT conforms to the rules of the            ;
l l      ASME Code, Section XI.                                                                  Repair or Replacement I Type Code Symbol Stamp'                                                                    N/A Certificate of Authoriza 'on No.                        N/A                  Expiration Date                        N/A Signed                    jey' d                        />                    Date          6-Z                          ,19    %
Owner h Desi.n.e. Tale "/
D.B. Lomax - hanager, Engmeenng Programs I                                                  - CERTIFICATE OF INSERVICE INSPECTION =
I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectoa and the State or Province of -          Arkansas                    and employed by              Factory Mutual Engineering Association                of Norwood MA                                                                            ' 4Wtp ' haveinspected the components described in this Owner's Report during the period                  10/20/92                      to 7/7/rf '/,#f 6?f- 4IfM9//
                                                                                                                          /      , and state that        ]
to the best of my knowledge and belief, the Owner has performed examinations and tiken corrective' measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed orimplied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shallbe liableinany mannerforany personalinjury orproperty damageora lossof any kindarising fromorconnectedwiththis                              i inspection.                                                                                                                                      !
k .'O ,      b _ // e N                                        Commissions              NB-9947. Arlh.-l133, "N" , "1" , "A" g                            gy                                                                    ~~. n- -, -
!          Date      SM                                    19 9 */
l l
l l
i
 
N.                  '
N ,ue m,.,M ?i2s2lU5                      iiEB a. . a.m..pie        ..m .4      , %;*2f(8]ijgf.#
h-. #5l'.hk5.
W e.. .s. m
                                        .. .iu P . ,, 2 w m..  ..
                                                                                                                ~~ /
                                                                                                                                        ~ .M I - 6 senry vont Machine C6i.1,oEisville/ Kr
        ,  y,4,,, ,                                    and Aeor, soe N cerimeete noiser t=Ar kansas        Power & Light Co., Little Rock. arf fN U-4/ 6d//
      .2                                              ,
: 2. Manufectured for                      ,"rItans    N ,e % , % , lear One, Russellville. AR A                                                                                        1"
: 3. Location of instaff ation                em. .ao meervem                                          1"              Outta sin _        Unch)
C8 Y81YI                -. Nominsi inlet Sin _        OncN
        & Pvmo or valve __
(c) Canadian                                          (f) Net'l    (g) Year (al Model No., (b) N Certmcate Holder *SRegistration                (di Drawing I
Serial                                                                      Od. No.        Sullt series No.                                                          No.            (e) Ctees j  4,                                                    No.                      No.
or Type                                                                                              -          1983_
1 N                                                                            -          B 49832 Cate              31-215017                                                                                                  -
gij                                        'D"                                                                                                                                      i M        (2)                                    55-213017                                                                                                                                    1 0)
O        y, (See Attached Sheet)                                                                                              -
v          (5)                                                                                                                                                    ._
    .s .*
O                                                                                                                                                    __
(7)          _ . .
N1
    .O in                                                                                        -- -
M (10)                                                                                                                                                            __
: 5. -                                              isaw e-..c.+, er .-wee w wn.cn eau omene e e e.en.e O                                                                                                                                  1500                _ g3,
                                                                    - poi -                      Y of Veno Pressure Ctess O    6. Design Conditions                                                  (Temowmure
:Prg          - poi at 100T.
: 7. Cold Working Pressure _.
E Pressure Retaining Pieces Remarts Manufacturer Matenal Spec. No.
Mark No.
ts; Cartings I
A                  l l
1 I
(b) Forgings Body                                                              Vogt                                                                                    l I
                                                        ;            S A-105                                                                                                                  t !
R4601A Bonnet                                                            Vogt
                                                                                                                                                                                    ]
S A-105 R4613A l
I (1) For manually operated veNes onN.                                                                      i i 81.2* x 11*. r2) inforrnstler. n
* Supolemental sheets in form of lists sketches or drawings                                          i        may be used provided (1) s te s items 1,2 cred 5 on tNs Date Report is included on each sheet, and (3) each sheet s                                                                                      J
                            ~~w et too of mie form.                                                                                                  ~ - - - - - .                        ._ ,
 
i
  ; aw -                  s.            - .                __ .
                                                                                                                                  ..; vib a,sm.A s.                L*
Yhb.UNb..%'.,'. 3 -.$.p , . .~.
                                                                                              ~-
                                                                                                                    .wNb  is zm v w w                        . '
e
                                            .v
                                                      .. ,r. c:    . . . . ~ . - - - - Jr"?'m,, o.tcH STAonrrec3r r.vW                                        ,
,p h, x. 'f. asviAv
                .            9 ewo* rumun w= W.P'V:                                                                        ^*'      RmW 4      5, .
                                                      %t'edel spec. No.'" '                    " %'riu M h7tSr''" "                                        .e Mark No.                                                                                                              .-    S'"'+
;    (c) Sottine                                                                          '
l                  Cao Screv                                                                    Texas Bolt B7                      SA 193 Cr. 57 I
(f) Other Ports Bonnet                                                                        Vogt HHD                        SA 479 I.410 (Qtemistry Only)
O
  .j j
5 400_ ,,,,        o;,, o;,,,,,,,,, ,,, ,,,,,,                                                                                                  \
  .. s. Hvoroetatic test _                                                                                                                                                        i CERTIFICATE OF COMPUANCE O                                                                                                                                f        t the rules of O      We certify that the statements made in this report are correct                                                    and thatU74 iv / Edition            this pumo,  _.        or volve, con orm construction of the ASME Code for Nuclear Powce                              .-      Plant Components.
                                                                                                          //        Aetober Section  IX  1983
                                                      , coe, c., u .
Addends _ Suruner ' 75 Henry Voht Machine Co.                                              g& --                      /M Signed              mc,., ~ ,            ,                                                    N            --symbol empiree 1/6/84          _,
9 07        to use me _                                          seen cm Our ASME Certificate of Authorintion No. _
CuuiesCAT)ON OF DESH3N
!                                                                                Henry Vogt Machine Co.
4        Oesign information on file et                                          Henry Vogt Machine Co.
Stroes enshsis report (Close 1 only) on fise et _
Larry D. Young Design specigcations              certified      by (1)          4557 Ar ansas              _ Reg. No.
PE state                                            R. S. Perry try til l          Stress anatp"is      certir "E"C                Reg. No. _ 5380 PE State __
(1) Signature not required.1.ist name only.
Ct.,5nFrCATE OF SHOP INSPECTION d Pressure Vessef Inspectors t, the understgned. holding                Kentucky a valid commission- and        issued    by try employed    the National Board of Boiler anCounnercial Uni and the State or Province of _
Boston, MA                                      have inspected the pump, or wahre. *1esenbod in this Date Report on of _                                39_83 . and stete thet to the best of my knowf edge snd belief, the N Cortificate Holdec ha Sept. 27 structed this pump. or valve. in secordance with the ASME Code. Section ut.                                                                Y; By signing this certif'scate. neither the insoector nor his employer makes any warranty,                                      fiable in ar'y ibed in this Data Report. Furthermore, neither the inspector nor.his employer shafi be the equipment d r property damage or a loss of any kind arising from or connected with this inspectie manner for an - rsonst '
l 0 o,ber            ,              g                                          Kentucky 11 W NAM #A                                                    com m;,,,ons overi se, sm.. em ano ca.i
                                / ' v.c.n,i
 
Page 1 (Front)
FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI 1 Owner APal/Entergy Operations,Inc                                                Date      05/21/93 Name Rt. 3, Box 137G, Russellville, AR 72801                                        Sheet        1-              of        1 m e.
: 2. Plant          Arkansas Nuclear One                                              Unit            Two Rt. 3, Box 137G, Russellville, AR 72801                                        JO# 00866837 Addren                                                      Repair Ortaan*=i P.O.No Job No etc.
: 3. Work Performed by AP&I1Entergy Operations, Inc                                  Type code Symbol stamp              -N/A Na=*                                    Authorization No                      N/A-Rt. 3, Box 137G, Russellville, AR 72801                                        Expriation Date                      N/A m e.
: 4. Identification of System HPSI ( 2CCB-4 )
SECrIII                        Edition, S 73                Addenda, N/A 5.- (a) Applicable Construction Code                              19 71                                                                  Codecase
      - (b) Applicable Edition of Section XI Utilized for Repairs of Replacements 19        86
: 6. Identification of Components Repairs or Replaced and Replacement Components ASME Code National                                    Repaired,            Stamped Name of                Name of              Manufacturer            Board        Other-            Year        Replaced,          (yes Component                Manufacturer            Serial No.              No. Identification        Built    or Replacement        or No) 2* GLOBE                TARGET                3                    N/A          2CV-5016-2          1977        PART                  YES VALVE                    ROCK                                                                                    REPLACEMENT N/A N/A
                                                                      "'^
N                                                      "'^
N
: 7. Description ofWork REPLACED VALVE DISC
: 8. Tests Conducted              Hydrostatic l        l Pneumatic l    l Nominal Operating Pressure - l        l Other l    l Pressure N/A              Psi    Test Temp N/A                    F
      ' NOTE: Supplemental Sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8'- 1/2 in. x 11 ina (2) informa-
      - tion in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
-(12/82)                        This Form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N.Y.10017 REPRINT 12/91
 
                                                                                                                                                          ~ . .
PageI(Back)
FORM NIS-2 (Back)
  . 9. Remarks REPLACED VALVE DISC WITH NEW DISC S/N 5
                                                                                                                                                                    ~
Applicable Manuracture's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this              REPLACEMENT conforms to the rules of the ASME Code, Section XI.                                                                      Repair or Replacement i
Type Code Symbol Stamp                                                                      N/A Certificate of Authorization No.                      N/A                      Expiration Date                                  N/A Signed                .f#. d__            m -
                                                      />                              Date              5-Z                                  19 %
D.B. Immax - Manager, Engineering Programs
* CERTIFICATE OF INSERVICE INSPECTION -
1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of            Arkansas                  and employed by                Factory Mutual Enginaring Association                                  of j        Norwood, M A en hayinspected the components described in this Owner's Report during the period                  10/20/92                        to #7h/ i '~/?# N9/(V                            , and state that to the best of my knowledge and belief, the Owner has performed examinations and (aken' corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed orimplied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personalinjury or property damage or a loss of any kind arising from or connected with this inspection.
k      O.      [_/d      Inspect #s Sipature Commissions                    NB-9947, Ark.-Il33, "N" , "I" , "A" Nabonal Board, State, Prmince, and Endonemesas
    //
v                              10. Elliott Date        S/3                                19 94/
 
Page 1 (Front)
FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI I
i
: 1. Owner AP&IJEntergy Operations, Inc                                            Date    04/13/94 Nanu Rt. 3, Box 137G, Russellville, AR 72801                                      Sheet        1                  of            1 Addras
: 2. Plant        Arkansas Nuclear One                                            Unit            Two Rt. 3, Box 137G, Russellville, AR 72801                                        JO# 00875223 Address                                                  Repar Organamuun P.O.No., Job No.,sec.
: 3. Work Performed by AP&IJEntergy Operations, Inc                                Type Code Symbol stamp                      N/A                      l Nann                                    Authorization No                            N/A                      1 Expriation Date                                                        I Rt. 3. Box 137G, Russellville, AR 72801                                                                                  N/A Addre-                                                                                                          !
1
: 4. Identification of System SGS (2DBB-100 )
: 5. (a) Applicable Construction Code SECT m                      19 7}      Edition, S-73                    Addenda, NA                    Code case    l (b) Applicable Edition of Section XI Utilized for Repairs of Replacements 19        86
: 6. Identification of Components Repairs or Replaced and Replacement Components ASME Code National                                          Repaired,          Stamped Name of              Name of              Manufacturer            Board      Other                  Year          Replaced,              (yes Component            Manufacturer              Serial No.              No. Identification              Built    or Replacement              or No) 3/4" GLOBE            BORG-                  2758                N/A        2SGS 21B                  1974      REPAIRED              YES VALVE                WARNER
\                                                                  N/A N                                                      N/A
: 7. Description ofWerk WELDED TUBING ADAPTOR INTO VALVE END
: 8. Tests Conducted            Hydrostatic l        l Pneumatic l    l Nominal Operating Pressure l              l Other l      l Pressure    NA          Psi    TestTemp NA                        F NOTE: Supplemental Sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
(12/32)                      This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 REPRINT 12/91
 
      ..            . . ~ - . - . .                                .                  .        - . - -                            ..        .
i Page 1 (Back)  l 4
f 4
l FORM NIS-2 (Back) i
: 9. Remarks NA                                                                                                                                                                    !
;                                                                                Applicable Manufacture's Data Reports to be anached v
i a
CERTIFICATE OF COMPLIANCE                                                                              I We certify that the statements made in the report are correct and this                                REPAIR                conforms to the rules of the            !
ASME Code, Section XI.                                                                                  Repair or Replacement Type Code Symbol Stamp                                                                                  N/A Certificate of Authorization No.                                      N/A                    Expiration Date                                  N/A Signed                          Ad owner d Owner's Desiance. Title                  I M                              Date            5[g.
                                                                                                                                                          ,19 %
D.B. Lomax - Manager, Engmeenng Programs CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State                                              !
or Province of                        Arkansas                      and employed by              . Factory Mutual Engineering Association                            of      l Norwood. MA                                                                                                              inspeted the components described in this Owners Report during the period                                10/20/92                        to AF 7hMhavyff ~        , / #//dfv ,and statethat                    <
to the best of my knowledge and belief, the Owner has performed examinations 'and taken corrective measures described in this Owner's Report in accordance with the requirements of the AShE Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed orimplied, concerning the examinations and corrective measures described inthis Owners Report.Furthermore, neither the Inspector norhis employer
    'shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this                                              j inspection.
9 d,        [                                                                  Commissions                  NB-9947, Arid.-l 133, "N" , "I" , "A"
    #                                        . Inspector's Sipature J.0, Elhott National Board, State Province, and Endorsemeras Date    S/3                                                  19 9 s/
I 1
                                    - , . -                                              . ~ .                                                  -          -.        .
 
4
                                                                                                                                                .Page 1 (Front)
FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS l                                            As Required By The Provisions Of The ASME Code Section XI i
l 1
i    1. Owner AP&llEntergy Operations, Inc                                                    Date      10/02/93                                                  .l Nuw
]        Rt. 3, Box 137G, Russellville, AR 72801                                              Sheet        1              of        .1 4
m em j    2. Plant        Arkansas Nuclear One -                                                Unit            Two                                                    I j        Rt. 3, Box 137G, Russellville, AR 72801                                                JO# 00880722
: j.                                                Address                                                    Repair Organuation P.O.No. Job No etc.
;    3. Work Performed by AP&lEntergy Operations, Inc                                        Type Code Symbol Stamp                N/A Nm"                                        Authorization No                    N/A                              l l
j          Rt. 3. Box 137G, Russellville, AR 72801-                                          Expriation Date                      N/A~
                                                  * *"                                                                                                              i
: 4. Identification of System HPSI(2CCB-13 )
: 5. (a) Applicable Construction Code                SECTH1 19 71      Edition, 'S 73            Addenda, N/A                      code case j          (b) Applicable Edition of Section XI Utilized for Repairs of Replacements 19                86                                                            -
6.' Identification of Components Repairs or Replaced and Replacement Components f                                                                                                                                                                    P s
l                                                                                                                                                    ASME Code 3                                                                                  National                                  . Repaired,            Stamped 2
Name of .                    Name of                Manufacturer          Board        Other          Year        Replaced,              (yes Component                  Manufacturer                Serial No.              No. Identification        Built    or Replacement          or No) i 1
2" GLOBE                  TARGET                    1                  N/A          2CV-5036      1977        PART                    YES VALVE                      ROCK                                                                                      REPLACEMENT                            ,
N/A
                                                                                "'^
N                                                                  N/A 1
N/A
: 7. Description ofWork REPLACED VALVE DISC
: 8. Tests Conducted                  Hydrostatic l        l Pneumatic l    l Nominal Operating Pressure l        l Other l        l Pressure    N/A        Psi    Test Temp N/A -                F NOTE: Supplemental Sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) informa-
;,          tion in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. -
(12/82)                            This Form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N.Y.10017 REPRINT 12/91 i
 
i                                                                                                                                                  !
1                                                                                                                                                    l
!                                                                                                                                                    i l                                                                                                                                    Page 1 (Back)  l i                                                                                                                                                    i 4
}'
l                                                                      FORM NIS-2 (Back)
: 9. Remarks REPLACED VALVE DISC WITH NEW DISC S/N 19
)
i a
i l
i k
CERTIFICATE OF COMPLIANCE j                  We certify that the statements made in the repon are correct and this        REPLACEMENT conforms to the rules of the j-      ASME Code, Section XI. -                                                              Repair or Replacement i
!                                                                                                                                                    1
!      Type Code Symbol Stamp                                                                  N/A                                                  j i
j-      Certificate of Authorization No.                      N/A                  Expiration Date                      N/A
;      Signed                  d 3,                                              Date            6-E                      ,19 94 l                  Owner o(Owner's Desinnee. Title -
D.B. Lomax . Manager, Engineenng Programs
?
CERTIFICATE OF INSERVICE INSPECTION i      I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State
!      or Province of          Arkansas.                  and employed by              Factory Mutual Engineering Association              of Norwood, MA                                                                        W haveinspected the componentsdescribed
;      in this Owners Report during the period                10/20/92                    to*7h h r '/,b M 7    #
                                                                                                                      #[fM9# ,and state that
:      to the best of my knowledge and belief, the Owner has performed examinations'and t'aken' corrective' measures desenM in this t      Owners Report ir. accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed orimplied, concerning the
!      examinations and corrective measures described inthis Owners Report.Furthermore, neither the Inspector nothis employer i      shall be liable in any manner for any personalinjury or property damage or a loss of any kind arising from or connected with this l      inspection.
1 k.O- [ U~                        -
Commissions              NB-9947, Ark.-l133 "N" , "I" , "A"
^
h                            Yoj [                                                              " M "' *' "
Date      S/3                              19 9 '/
W 4
 
d i
!                                                                                                                                          Page 1 (Front)          l FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS                                                                                  i I
                                    . As Required By The Provisions Of The ASME Code Section XI                                                                  I
!                                                                                                                                                                  l l
: 1. Owner AP&I1Entergy Operations,Inc                                                Date    02/14/94 Name Rt. 3 Box 137G, Russellville, AR 72801                                          Sheet      1                of        I ue-                                                                                                                      ;
: 2. Plant      Arkansas Nuclear One                                                Unit          Two Rt. 3, Box 137G, Russellville, AR 72801                                          JO # 00884165 Mdress                                                      Repar Organizauce P.O.No., Job No.,asc.
: 3. Work Performed by AP&IJEntergy Operations,Inc                                  Type code symbol Stamp                N/A Nams                                        Authorization No                    N/A Rt. 3 Box 137G, Russellville, AR 72301                                        Expriation Date                      N/A use.
: 4. Identification ofSystem LPSI(2GCB-7 )
: 5. (a) Applicabic Construction Code      SECT. HI 19 71        Edition, S.72              Addenda, NA                      Code Case (b) Applicable Edition of Section XI Utilized for Repairs of Replacements 19          86
: 6. Identification of Components Repairs or Replaced and Replacement Components t
ASME Code National                                    Repaired,              Stamped Name of              Name of              Manufacturer                Board        Other            Year        Replaced,              (yes Component            Manufacturer            Serial No.                  No. Identification        Built    or Replacement            or No) 1" GATE              BORG-                  1684                N/A          2SI-1040            1973        REPLACED                YES VALVE                WARNER 1" GATE              WESTON                347                  N/A          2S1-1040            1973        REPLACEMENT YES VALVE                HYDRAULICS 1" GATE              BORG-                  745                  N/A            2SI-1041          1973        REPLACED                YES VALVE                WARNER 1" GATE              WESTON                1668                N/A          2SI-1041            1974        REPLACEMEbfr YES VALVE                HYDRAULICS
: 7. Description ofWork CUT-OUT & REPLACED VALVES i
: 8. Tests Conducted            Hydrostatic l          l Pneumatic l  l Nominal Operating Pressure _l          l Other l    l Pressure      NA            Psi    TestTemp NA                    F                                              l NOTE: Supplemental Sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) informa-                      i tion in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.                                                                                                                          1 (12/82)                      This Form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N.Y.10017 REPRINT 12/91 l
 
Pcge1(Back)
FORM NIS-2 (Back)
: 9. Remarks NPV-1 MANUFACTURES DATA REPORT FOR REPLACEMENT VALVES ATTACHED Apphenble Manuracture's Data Repons to be enached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and th                                                                                  REPLACEMENT cmforms to the rules of the ASME Code, Section XL                                                                                                                                                    Repair or Replacement Type Code Symbol Stamp                                                                                                                                                    N/A l
Certificate of Authorization No.                                          N/A                                                                                Expiration Date                              N/A Signed                          j,/ [                            /j'                                                                                          ' Date          6 - 2.                              ,19 %
Owner gf Owner's Desiance. Tstle                    /
D.B. Lomax - Manager Engineering Pmgrams CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of                  Arkansas                          and employed by                                                                                  Factory Mutual Engineering Association                          of Norwood, MA                                                                                                                                                            Ac#              nspeged the componentsdescribed in this Owner's Report during the period                                              10/20/92                                                                          to 7/7/#F havej#67/ YA/9# ,and state that
                                                                                                                                                                                        '0 to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer snakes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.Furthermore, neither the Inspector norhis employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
h . O.              [                                                                                                                        Conunissions                NB-9947, Ark.-Il33, "N" , "1" , "A"
(/                              Inspectes signature
: 10. Elliott National Board, State, Pnmnce, and Endarmerneras Date                  8/3                                    19 9 V
 
y--                            _ __
ASI- /C VD                                    -
                                                                                                                                                                                                              %o .st'7                                        .
4.
l'ulN NPY. I \l ul'l'Al*lVill'.llV ll.\TA Ill:l'OllT I Ull NI'( l.f: A!! I'INI' Mill val.\T.*
* b lle.piecil Iy slic l'rast.la . af the WlE 1.. fr 1(.I,.                                                                                                          . ,
w_ .u.          a s s .rv v - 5 . ..                    r      u.= =.m .=..          r,
                      . . , -,. =:.: .:- n . . v. . .-. - v .es .r-r a a.,
                                                                                                                          -r.
m,,      _
L Van Nuys, Ca._orde, M,_'A4E496                              ' ' * * " " ' * * ' * **
Ye.st.em. .Ifp.t.ra.u.l.i_c..s. , 7S. 00.T.y.rone            .
su,e.)                Avo.
: 1. Ms.eru e eeJ 6,.                -                .
(M.s.e & Adas..e of W ud 90 6 San Francisco Oed.e No. 6600.N.2114.ls f_                                                                                      *
: 3. g
                    .f.,,,,,,a f.e Bechtel P.rwe.r... C_o.
                                                                                                                . .r.p. . - P O Box.
d AAa....I                  Call 3..            ornis tw
  ~~                                                                                                                                                                          _.
Ark-ana n s..P.o.we.r. .a.n. .d . L.i gh.t _co.m. p.a.ny.
S. O ,,,
l'*
Lt.t.t,1 c ,Rpc)[,_Arknnasa
> q 4, t <ssive af Ptsee                                                                                                                                                        Tag Ito.            1" CCA-Gr                    __
1" Ge t.e_ V_a_lv.        _            .o t O S. la e w vote,                    Jr. ;r;,.ii                      P. .a r.t Kuvib.e.r. 700.80                                                                                                                                                          u
      \                                                                                                        793.
747 (25 Ysivos)                      . ._ .
8*@          --
Se.r. ial Kusib.e.r.s .343...e..
                                                                                                      - 3 58,i          n... v.a............
                                                                                                                                . e. .,. .i._., ..
I M                                                                                        _ .              . _ . _ -
>~9~                                            70080                                                      p,,r.,,4 We_s.t.o.n if.yd.ra.uli_.c.s_            -
p
( a3 f)i .. .      h.
a..
(M N.iioa.1 q..,4 sf.._ _. ,
100 ,                ,,.-
3600              , _ _ , ,g _                                                        *      -
)          & tiesism Coadisi.a.                          _
i r .. . ...:                                      st r...s            :
r
                                                                                      ..J ..,6...                6;,          rii,. .iiusur. c.4, s, ; in ci.. .                                                                            ,_.
)          7. n, ....;.i. 4..;g. , ..... i.
                                                                            . Am.e n,,, __s.u_w,y. .'.72,__. c. ., n . _. .
r4;.t _.1971                                                                                            ._
u      .sw.                                  a.. s.
u.. .. ., s r.. . u ..                                                                                                          . .
                                                                          - - . .                                                                                                                                                      .a att C.siins.                                                                                      SA351-CFS1!
Cate - Code 1 A.:3, 1A51                                                                                                                                                                            _ _ _ . .
R.o. _x T*re. .c.i s.i o._n
                                                                . 7039.3 ._. _ .
_. . . .C. .a s t. i n1        .
Koston Ilpirrulles Itachined - 7G108                                                                                                                                                                              _ . .
_ . . . . . . . .                                                                                                                                                                                          -~ ~
                                                                                    ...__.-                                                                                                                                              ~ - - -
                                                                                  . - .                  - - ~                                          - _ __
(H F a'*ia t'                                          _ . . _          . . _ . .                  _ _ _ ..... ..                              . _ - -
                                                                                                                                                                                                                                      = _ . .
M1 x2-P.110 nott1 - cer.f o 1/c10!'                                                                                                  Pacific Torge                                  ,-
                                  . Forging.. 7. 03t:7                                                                                                  Lf9 .s.tqn Ilydya_ul.1_crj                                                                    ,,
_ _Ma eMn94 , . 703.~10. _. ._ _ .                                                    . . . . _ . . . .              . .
Ib. d.y . A. s s '.1                        .7032._9 Weston !!.vdraulics tionnot - Codo 1A46                                                                  SA182-T316 Forged Etock                                                                                            ..
                                                                                                                                                          .f_orge.nt:e..n
                                                                                                                                                            .            . .          .C.o. _          ._
Lfestein Ilydraulics                                                                _
l'.nchined - 70324                                                                                                                                                                                              .
                                                        .=_
p3s.r.,        u i. n.        .t.2.5. .ad
                                . si .s.b.tw.. n....                                                                                                                                                  , ded . i.e . su. r.
6.i+ e w
            <s.e,t, de..i.e...,6....dp...w.4(n                  .u s en..e, 4 (*;            e,s.sw*,na.s.
e u n en..i se =>.ee            ese.        d as.o.    ..i ,,,.,,. .h. se6. swi.,o              d
                                                                                                                                                                                                                                          -p                7%
g--                  i  .g=-av--            -N,v      , , - 7 i-gr7 ; i g gg 4 ,=.
                                  """'a""***                          - - ---                          --.,---.-q                                                                                                                      .. ... ..
 
                                                                                                                                                                    ~
  >                                                                                                                                                        . .v .
G 0 e61                          .v 11)lN Ml'V.I                                                                                                                                                                                            ,
e ,,, . ,
                                                                                            !        is ....i s . . w                            u s w.                                                                                                                                                ,
: u.                                        .      _ . _ . .. _                                . - . _
t s_
ses .fi.ase.i                                                        _                _ _ _ . . .                _ .                                                                                                                                                                      '
                                                                                                                                                                                                                                                                                        =.              ,
N
                                                                                                                                                                                  -                                                                                . ~
                                                                                                                                      - . ~ ~y        i. .
                                                                                                                          . . A.                                                                                                                                    - -        . . .
id, ~., . .                                      ._
N
                                                              -~~~
p,.
M                  -
29                _.
en 6400~IIES    -                            - P*I-n  s. Mrde umie <<a
                                                                            ......          ChllT111 CAT 10N OF DESIGN
    ,o                                                                                                                                                                                                                                                                                __
veston frydravt.,Jes. 7500 Tyrono,,A.vo_. g. Van _Nuys. Ca. 91409 O      p,,;g ;.r.,.uin.                        r.tc .,
W ton Hr}!raujf,csdS00 Tyrone A_ve.. Van 1.'uys. a,g.x.,                                                                                                                          Ca. 91409      2516 5
                          . trois sepers              fite es . ita                                                                            _ (3) p,.g, t g. 5,,,, Texa s
          .e.er..
g    pe.ig. .pecific.si e eerillied by _).4_N_4,,,,,If.988rtl. Jr._ : 3 p,.t.t.s.si. . Calif mes.x 13.700 s..e..          .tr.I. .ep.ee ce.iiried i.r Jr L _ citarie, O      (1) Sip.i.ie aw .<<reiseJ.1.i.
e c.fy.                                                                                                                                                                                  -
j C
Ce eretify shat the st.trement navle 3. shie seport .te snetece.
itg                                ,,r_ _
S          .._4__ O. s                                                                                  __          ..                ,
o,,, 26 oct ober                                    n?3            s;,,,,, wo_st.on.g,,,_rau.lle    g              ,,.-            s
_ e,p;,c.p.ssow,r Is __19.7p                                                                                                                                                                          i 533 r ,,s;r.<... .: 4. i..,,i,.n.. x..                                                                                                                                                                                                                                                                i e
t
                                                                                , CElrill1CATF.Ul' Hl01'IN!J'ECT1(W
      .                                                                                                                                                                                                                                                      ve..es I.. pre....
l i, ik ..d,,.;p,d. h.us., . .11J e                                              i.1 l
: i. sed hr ehe N.ii . pa..I t it.iies ..a Pee...,e..a e ptuyeJ I by Dep
              . 4/a, she t e.ie at l's .ine e of CaliffirA A _                                                                                                                                                                                                                kistise.
_ _,,,, h.,, ;.,puie a .6, e ,p,;p.,,,, g,,,,;g,,4 ;. i
              .i __ C.i t 7.9 ..      f Io?..A'ICO I.y a J klief, abe Ha..f.eteser#                                                              ,
                                                                                                          .a.I .f.se sh.# sa ehe !=r 44 et my h ansfeJp .*                                                                                                                                                        I Report            M . eed    .kNski        I' .6 e S.s.p      1920 .                                                                            c tt f.ede. L esic.d[ft.                                                                  .e implie.1 c e stie b.s        e e.
r .ee.c                                                  =v.4 is #er ,wdaare sieh she applir.!Je 5.b.crain..                                                                                                                      4Aa                                                  I ft- signi.g shis erreifirase, e.cist.ee el.e in g.ertae                                                  l s.cecher    see    his    employe,                  m.bre                                                any                e.se.asy.            espsesse i g she e g i rse.se de.4eilarJ i. ibio lisi. Repnet. Festhess.oes                                                ar kiaJ .,i.i.g she        i..        eI..pers.is raa.erse d .iih                                                          n.. ibi.his  i .p,ecopinyee n n.                    sk.11 he lia mu.3,e 9.. .i y n,e u.. 1 se.i.er , r .ve r sy .t.n..ac w . l.. . e                                                                                                                                                                                                                                  .
2G October                                        ._ g,73 -                                                                                                                                                                  .. .
p ,,,                                                        . .                .
                                        .n, ./,4.hua  .s                  .
                                                                                                                      - t.    , . .i . -
                                                                                                                                                          ,,..          ,. 4 .n.. ,.                                                                            .        . ,
0 p,
PQQ.a8,, OPJ5w.~AL vh..,-,k,,...
                                                                                                                                                            .. . ,, . ~.-..
{                                                                                                                                                                                                                                                                                                  .
                                                                                                                                                                                                                                                                                          --      m,
                                                                                                                                                                                                  -                                      - ,,,,                          ~g
                                                                                                                                    ~
 
257-/09f' Ve - M6b' l
l' Ult \1 Sl'V. I \l \Mll'AC'll'lti It%* Il \TA llEl'OltT IJtHI NilCI.lMit l't Til'% Uit l
A. ItriquireJ l.,s ilic l'e..u i.. . of slic A* ale Cmfr llele.                                                          _ ,-a,
                                                                                                                                                                  . _ v . _-.u , .
p6                            ---..-m..-__.                              umun .r                u s., -:.s ~a m- - ~ ~_.m
    ,U            _ n_-
                                                                                                                                                                              ,,, Aq14 pg,,
7500.T,y rpn.q          .e ..Av.g
: s. us..(.ci..ed by Wes t o_n, if yd ra ul t.cs,.u m . a A44.... .: u                  .we . ,Je n lt.uyL._CA.o,4,, s.
I San Francisco o,de, g., 6600-N-2]J 4..il                -          .
2.
ua,,,,g.,,,,,a g,, Dechtel Powe <r wCore,.                              . 4 A.wP.O.      ..a Box 39J6                      CA I
I D            o. .e.
Arkensaa Power and Ligh,, Co,                      t epa _n_r f
m .3.          .
Little Rock, Arkennes
: a. , e..;          .f eu...
I'' CCA-gr...
Part Number 70080 1 inch Cote Valve Te g_,,No .
_        $. p. p Vol e IJc ificatiea Serial Numbers 1145-1149, IG50-1609 (25a.m                                              Valves)                    4..ie..<a Q            -~                                                t o, .e 4. w,a,.i    .e .. i. . s=                  . 4        .
D            _ _ _
M                                                                                                          Ncs t ort .Rydraulics . .____                                    -_                .
(
(.) ne s. ;a g No. . . _ 0. 70080 , ,,, __ _,_, p,,p.,ed I.y __                                                                                                                              ,
o                                                                          .
f (b) Naisoaal lieaed No.
* 00                  _ p,;              100                  of .                                                                      p
                                                                                                                                      ,                                                                                C
: 6. ne sign Co.Jisiaa.                              c c.. . ...,                              it . .
O                                                                                                                                                                      I                . . . .            r 3
: 7. The maereial,              s      los a. c.aur.ciion, and .oehmsaship cu,nplies wist A$uE Code Section Ill. Class 1971                --_ , AdJceiJa Daic Summer 1972                        - . Ca se No.
3 .i n .. _ _
u.a.s ui e n                          m..                              '
u .. .. ..i s,. e . p ..
u..a et..
tal Ca uia s s                            ,
S A 351-CF8M                                                                                                      ,
Gate - Code 1 A51                                                                                  Rex Precision                                              "
l Casting - 70:19 3 ~                                                                            Weston Ilydraultes
                                    ~ ~da~cIii'ne T " 7'04'0'H                                                                                                                                                            ,
i l                                                                        _ _ _ -
I                                                                                                                                ..          -_
i                            O'l I *L81a 8 '              _.____L.                  l _ L._.                                    -
                                                                                                      . . .SA 182-F316 I                                    Uody - Code 1A3G,1A53 1AS7                                                                          Pacific Forge 2                                        Forging - 70307                                                                                weston !!ydraulles Machined - 7033G                            _
Wonton Hydraulics Dody,Assy.                -  70320
                                                                          - 6. -
4 SA182-F316
"                                      Bonnet - Code IA46                                                                                  Jorgensen C o.
4                                        Forced Stock                                                                                      Weston Ilydraultes                                  ~
E                                                                                                                      ,
N                        uschined - 70324 4
[j
              \
                                                                                                                                                                                  .u.a a. ii... 8. 2. s. .
( n .t.. e s w*n. sn
                                                                                                                                                              ...".,.m u ...t.,,, e .i ., .e imi. s ..
L G,
i
                          .e p...w.4s n .. iu. 4. .w.i. . ..
es.,,ci....i.:.h....i.t . .tn e..... .h.. .,4...ias. ..e v.
: s. s.. :.4,4 .a . .. h eh. . i. ..a o n . .e n                            . 4 . a . t , .t
                                                                                                                            . i. . i,..
d)
  *.1  ,
                                                                                                                                                                                          ..g.                              (
a                                                                                                                                                          ..      ..        .
 
          .t
              ?                    .
w                                                                                                                                                                                                                                                                  r j
FOIDI NPV.I (l ek)                                                                                                                            F s...                                              p.
1                m.                                                    - _ . .
: m. ....i s,.. . w..                                        - _ _ _ .                                                                      a e
w..                                                            I t p inasisas e,
                                                                                                                                                          .          .      .__ _ _                                                                                E
                                                . .._ ..                                                                _p          .
g
                                                    . . . _ _ . . . . . . _ ..._..___                                                                                                                                                                                  t
                                                ...__..__                                                                                          ..-          _ __                                                                                                  F f
t, (d) 0. hee i,'aeis,                                                                                                        -
g                _ _ _ . _ . . .
                                                                                                                                                                                                                                    -. _                                =
g                          ..
f p
N                  ______                                                                                                                                                                                                            . . . _                      .
O E                                                - P83.                                                                                                                                                                  I Crim 3. Ilyd,os sei, sese....
CFit11FICATION OF IllNGN 4                                                                                                                        .
s          91409 j                          go,l_c        f 1), mig. infeemailen as fil' #8 ISEI[0 )k1N0.U,1, s.M                                                                                                                                                Res.Ne. 25165 leon s.rd , J r.                                          g 3 p,,t, ng, $,,,,Te x a s                                                                5 Seess analysis arpews e='s Isle et _                                                                                                                                                      CA        Re 8. No.13790 q~      ocaign specificae; . .,,eir.edR.by_E. Jj oL. Citerley                                                                                                          - (!! Prof.hs.Sasse l
c)      S een. ...(y i. ,ce..,. . .eiified lar g i3 ei g,.
                              .. w ..;.... J. I.i.e name =ity.
C l'c ecosity it.ai ih, ,,, . cnes made in ibis sepose are correct.                                                                                                            CA d' , '-                                          _
gay 19 2.f          Signed _. Wpston.,,,J.fygreg11ps na,, _ J anua ry _21,                                                                                                  tu. r . .reet 533                                        _ e,p;,c, _Docember IL _19_75 ce reir e ase i,t A.eh..rie.ai*a No..                                                                                                                                                                                                  '
CEltTIFICATF. OF Sil0P INAl'ECTION l board of fleifer sad Peessvee YesselInspeesors Dept of D1dg. k Safety -
1, she vndeenig sJ, holdiaA                                  California                                  a valid enmmistisui and employed I,y. issued by the Nailena                                                                                        ,
I ha , ;.specied the eq,ip.e. 4csc,ihed i ihis nais on.1/or she N ase I l't.**Iat' *I-.                                                                                                                                    y nn..lcJac aw belief,ilic usavfaceveer                                                  f
                  .f __C1&y_of Ma Angeles                                                                                                                            h      n,r e .f J $cciion lit.
Res .ev en _ Jontis t Y_2.)_,39,li__, ed since ihai se c eni in                                                                                                                                                                                                  f' h as c e.i s seve erd thi . i ge                          n< itten ilie inspecs.w seat his emp,loyer msbes a.y wastans ,                                                        his.nempleyre e nedance    shall  3ishbe liable n
she applicable in sayy espsesseil  khscrtions l    e
* J
: 11) signing sleis e , sei ic as ing she eqwipencas se                              Jrueleis  's,lacJ                      liaia      ,c,Reperi. Ferilecemnre, scialie, slic lampeciot metdamage ce a' loss of                                                                            -
                                                                                                                                                                                                                                                                                  )
1 say k manaes for any pre sver.l 88)#fy O' l'ulw-8'Y                                                                                                                                                                                                                  f
                                                                                                                                                                                                                                                                                  /
i                                                '
Janunryjl                                        __ 19_7 4 Daie                                                                                                                                                                                      .
s M8M Coennis sions _                                    s g e.            ..,e . o..>
ns.ii                                                                  -
                                        ,,......,8                          ,
194l1 Thle fera (KJf) le ehesin.6te (e.m the Asa:E, Ms E. 4Fah $4., Mee York, ff.Y P.
Pasaa e4 in V.S.A. (6/f g)
!.le :
mg
: o. .                                                                                                                                                                                                                                    ,.-
                                                                                                                                                                                  . _ . ,            .. n            .
___                  __        __-_--_.__._m.                _ _ . - _ _ _ . - _ _ _ _ _ _ - _
 
Page 1 (Front)
FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI
: 1. Owner AP&I1Entergy Operations, Inc                                                          Date        02/10/94 Name                                                                                                                    ,
Rt. 3, Box 137G, Russellville, AR 72801                                              Sheet        1              of          1 Aaaren
: 2. Plant                  Arkansas Nuclear One                                                Unit            Two Rt. 3, Box 137G, Russellville, AR 72801                                                JO# 00886957 Address                                                .
Repar Orgamzataca P.O.No Job No.,sec.
: 3. Work Performed by AP&I1Entergy Operations, Inc                                              Type code symbol Stamp                N/A Name                                      Authorization No                      N/A Rt. 3. Box 137G, Russellville, AR 72801                                              Expriation Date                        N/A Addres
: 4. Identification of System CVCS (2HCB-44 )
: 5. (a) Applicable Construction Code                    sum                  19.71      Edition, S-72              Addenda, N/A                              CodeCase (b) Applicable Edition of Section XI Utilized for Repairs of Peplacements 19              86
: 6. Identification of Components Repairs or Replaced and Replacement Components                                                                                                ,
ASME Code National                                      Repaired,                      Stamped Name of                      Name of                Manufacturer              Board      Other              Year          Replaced,                      (yes Component                        Manufacturer                Serial No.                No. Identification          Built      or Replacement                  or No) .
l 3/4" GLOBE                        WESTON                  1350                N/A          2CVC-10%            1974          REPLACED                        YES l      VALVE                            HYDRAULICS
'-    3/4" GLOBE                      WESTON                    1415                N/A          2CVC-1096            1974          REPLACEMENT YES l      VALVE                            HYDRAULICS i                                                                                      N/A N/A N/A
: 7. Description of Work CUT-OUT AND REPLACED VALVE
    = 8. Tests Conducted                        Hydrostatic l      l Pneumatic l      l Nominal Operating Pressure ' l . l Other l      l Pressure    N/A          Psi    Test Temp . N/A                F
          . NOTE: Supplemental Sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) Informa-tion in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.                                                                                                                              3 (12/82)                                  This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 '                                  I i
REPRINT 12/91
 
              .      -    - ..        ~. --              --                              .        .      .        . - -            - . -            -          -
I Page1(Back) i 2                                                                                                                                                                        ,
l 1
1 i                                                                          FORM NIS-2 (Back) -
l l      9. Remarks NPV-1 MANUFACTURERS DATA REPORT ATTACHED FOR REPLACEMENT VALVE 1                                                                      Applicable Manufacture's Data Reparis to be enached i
s i
i s
s
!                                                              CERTIFICATE OF COMPLIANCE l                    We certify that the statements made in the report are correct and th          REPLACEMENT conforms to the rules of the -
I ASME Code, Section XI.                                                                    Repair or Replacement 4                                                                                                                                                                        :
Type Code Symbol Stamp                                                                    N/A Certificate of Authorization No.                        N/A                  ' Expiration Date                                    N/A 3
]
Simed              lA /
Owner oubwner's Desiance. Title e4B2  5 o.te              s.r                                  .i,44 j                  D.B. Iemax - Manager, Engineering Programs                                                                                                            1 I                                                                                                                                                                        I s-CERTIFICATE OF INSERVICE INSPECTION                                                                              I
:        1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State j-      or Province of          Arkansas                      and employed by            Factory Mutual Engineering Association                                of i          Norwood. M A                                                                            AM havejnspected the components described 1      in this Owner's Report during the period                  10/20/92                      to #fAFF N/f/77 kW/6 ,and statethat 1      to the best of my knowledge and belief, the Owner has performed examinations'and tal(en co'rrective incasures described in this J.      Ouner's Report in accordance with the requirements of the ASME Code, Section XI.
!'          By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the                                  1 j        examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer                                      {
shall be liable in any manner for any personalinjury or property damage or a loss of any kind arising from or connected with this                                I j        inspection.
J J          90, [M                                                          Commissions                  NB-9947, Ark.-1133, "N" , "I" , "A"
          /7                        Inspector's Signature                                                    National Board, State, Province, and Endorsements E        V J.O. Elliott 4-        Date        S/3                                19 7 V
 
                                                                              . ; / J .. . !                                            '; . . . w . : ' ;.: . : ; . ; .          ,
                                                                                                                                                                                                                        ..    . : . . . nw. m..
fmyW.3'
                        ~                                                                                                                                                                                                  2 C VC - /0 96 l
                                                                                                                                                                                                                                                                        ~
                                                                                                                                                                                                                        % / V/5~                                          f      '
l'Ollil NI'\.1 \l.uul' A(.'ll iti.its' il \ 1 A Iti;l'ultT I Olt NULLl'\lt I'l \ll's 011 \ \l. VIM                    .
4I A Itcquircel in slic l'r.ni-ions of tiie NIE Cuk itule-
      '..                        O                        -.=.-              ..-===a._-==_==:.:=.:==::._=L===--__---
                                                                                                                                                                                                            ~ - - - - - -        ---                                        Te A4249G                                          [
ll                                    1. st.notai sure.1 t,y WC.st on flyd raulics , _75.00 Tyrong. Aye,#.,ypn._NuyECA_._orde, No                                                                                                              ,e
            ! >                                                                                                                i n . , 6 A,ia,e . . .: n noi .c iu e,>
l                                                                                                                                                                                                                                                                $
I f
Bechtel Power Corp.,                                      P.O. Dox 30G5, Snn Francisco g,g,,s,. 0600-M-2 _114 U_                                          _.                    w.
I Manufacioecd for                                                                                                                        C t'
      !      l
                                                    ..                                                                                        ( n . .... Addie e s)                                                                                                        -
1
                                                                                                                                                                                                                                                                          .g
                                  &                3. o.nse Arkone Power and Light Company                                                                                                                                                            b,.        ,
                                  ===
                                                                                                                                                                                                                                                        ,_                            f L1 t t]e noch,_ Arkansas                                                                                                                                            a          :
: 4. l.or niion of plan, e                                                                                            Number 70100 3/4 Inch Globe Yalve Tag No. 3/4" CCA-GU                              .
C l
pu.np or vals e identific ation __Pa rt Q
5.
y D                                Serial Numbers                            1400-1424                      (25                                                                                                                            p
                                                                                                                                                  . . Valves)
I
                                                                            ~
                                                                                                  ' ~~ ~~~      in',iis J.7,ien .,n                  ewe 7.'
* na h e quir-e ni -a.                d ineen a.
            'y                    t>=
* p                                                                                                                _ . .
                    ?
4                                                                    70100                                  1,separed by                  Weston li)rdraulics r
(a) Dra. .in t. No. _
O                                                                ,
                                                                                                                                                                                                                                                                            .+
1                  .
(b) Naiional lioard No                                                                                                                    ,
s-3G00                                        p,;              100                -
o g, i                              6. Oc *irn ConJi'ioa,                                                                                            (T e mpe n si...)
  .e                                g                                                                            s e ,, . . u, e >
be;                                                                                                                                                                                                                      I                            .
Tbc n.atreist. design, consouc tion, and morkniansliip coing lici m ith ASMI: Coitr Scrsion ill. Class fd.-                            f-)              7.
    @                                                                                  1971                                                      Summer 1972 - . Case No.
                        ,                                  I d aion..                                      . , Addenda Daic u _,mu.e.                      ......
H    .,                                                    - _ - .
u.,,...
u.ie...ne.....
(a) ( .t s u n g s
        , 3                                                                                                                      . _ _ . -
:n M                j s
  .,                j                                                  ___
N e                                                                  --
g                                                                    ..
c.
( b) I crpint.%
* IJqd y - Q_ ode JA52                                                              SA182-F316 4                                                                                                                                                          Pa ei fic Forg e__,
    ;              y                                                  __yor_gi ng - 70307                                                                                              Weston liydraulic,s_
m                                                                  jfael_Qned - 70308                                                                                              Weston liydraulies
___nody_ Assyn- 70315 l +
k                    D.                                                                                                                                                                                                                                  . _ __
h.pp_ct._- _CocLc_ J AiG -                                                    __S A.M2- F3 ] G .
                                                                                                                                                                                        . Jorgensen Co.                                                          _
Y                                              __Jqrged St ock                                                                                                  Weston Hydraulics
_M:Lchinnd - 70324 Mdt                                                                                                                                                                                                                                                                                '
* 1.
        *                    \                            *5upriemental shee ts in fe,m of Ilois, sketc*.s or drawinge enay be used provided (t) size le 4%": 33". (2) inform 5t> en ihls data report le included on escri sheet, an<f (3) each sliers is nuinbered and number of sheets sa recorded at top o j.g.;''
v.< n
,ts.4                                                                                        .                      .
                                                                                                                                                                                                                                            . - . .                                e
                              ,q                      .
: i. ,
i--
 
M                    (
t 4
l'Olnl NI'LI              (lincM                                                                                                                                  '
k 1
n,    .,6.
w u    ..r . < i .. . .                                                                                      d.
u .. n .
u . . .i se e, . x..                                                                            l,                                          -
fe) 15ni'ia s
                                                                                                                                                                                    - w __
                                                                                                                                                                                                                                                                                                                                    & 'r u                                            . . _ .                    '
6 1                                                              I l                                  .        .._
                                                                                                                                                                                                                                                                                                                                            )}
                                                                                .- . . . . _ _ . . .                                                                                                                                                                    I. .
                                                                                                      . _ - . _ -                                              . _ _ .                                                                                                                              - - - . - - .                        l          ,
_.__..._,.__,.._..                                                                                                                          v.                            ~=w-,~. - ,-=~                                -.v.-_.-
                                                                                                                                                                    ,-n .            -
h        4'
                                              ---n.-m.-,--~_--_-m,,,                                                                    .
                                                                                                                                                                                                                                                                        .k ._..
(.1) Onlict l'ibris                                                                                                          SA 162- 1'31 G_._ .
                                                . Disk.          _ Code IA4G.._ . . _ .                                                                                                                                    forgc_nsciLC                o._ _ _                                      _,        _
m                              _Fo rney). Stock _                                                                                                                                                          #cH.t on _Ilyd ra ul t es 8                                                  _ , , _ , , _                  .        c.
                                                                                                                                                                                                                                                                                                          . . . . _                  (                  .
                                              ,,,__ Machined - 70346                                                                                                                _ _ . _ . .                            _
                                                                                                                                                                                                                                          ...___..                                                                                          i g
                                                                                                                                                                                                                              ~ _ _
                                                                                                                                                                                                                                                                                                                  .-                        !    4
                    ,                          _ _ . _ _ _ .                                                                                                                                                                                                                                                                                l
                                                                                                                                                      . _ . . ___                                                                                                                                - ~ - --
_        . - .                                                                                                1 C                              ._._. _.._ __ _ ... _..
I e'
                                                                                                                                                                                                                                                                                                                                          .l.y; C
: a. itya.o..aiic it u.                      5400-5450                                                                  _ ps;.                                                                                                                                                                                        a n            ..s.                                                -__ __
r!
m.
Cl(IITIFICATION OF lil'.StGN                                                                                                                                                  c. t-9                                                                                                                                                                                                                                                                                                                      1 I
75,,00..Ty r,,one .Av,,e                                                  o  . , .Ya n.Nu y.s. CA,, . 91409 . . _{i                                    N[+      .
linirn info <m.nion ..a file a, .Wes t                                                              on.Uydrauli c4_ _ . . _. .._.
O                                                                                                                                                                                                                _ _ _ . . _
51GS                          ,
Sin u anai> sis n pne t on hie at                                          ._.
J r , _ _.                                        _ ( t ) l'rof.1.ng. Statc 7f X a $ ._ Heg. No. 2                                                      (,
M                i), sign spre ifii uinen e rstified to .. .jl, 4._1rgna                                                                  C i t c rl cy_
rd .                                                      (1) p,uf. l:ng.Staic CA . __ Re g. Nu._13790 J;                                                                                                                  R . _ l<.                                                        _
b                                Sur n s analy sis n pore s i riil.co by                                                          .
                                                                                                                                                                                                                                                                                                                                            ,M I            C)              ( t ) N ei.uun noi try .ier.f. I ist n.u .e ..nly.                                                                                                                                                                                                                                                              4 j                                                                                                                                                                                                                                                                                                                                            r d
sl ai rnu est s in .n .j s - ist this es port AIC s urrC(f.
M Tr f etid) il 46 ''.c                                                                                                                                                                                                                                                                                    [fa, .
[h f
ny C4 . ([.__ p4.                                      _ ___.
Ja n ua ry_22                p;__7_4_ S;,nta .yeston_                                                                          llyd raulics
                                                                                                                                                                            <u.....r.....,
I ) .u ,_                                                                                                                                                                                                                                                                                                  ;
q                                                                                                                                                        _ ,,p;,c,_Docember 18, J ,7,5 g                                  ( reista aie of Auchurie.uiosi No._ .. 33 5
M r.
e' w                                                                                                                                                                                                                                                                                                                                              "
5:
CI'.itTil'ICXIl'. Ol? Sil()l' INSl'l?CI'lON VesselInspessuts                                          .
1, ihr un.tenirn. .f, hohling a v ali.1 t umminion jourd by the Nasional lloard ni lloiler                                                                                                                                                                                        and l're} s weeand
* and/or the $iam of prodne e of _. .CD11.fprni a __                                                                                                                                      have inspected the quipe.e .. d< usibed in ibis Data Clty      of  ins    A u[;e                  l        eS..                                . _.      ._.                                                                                                                                                                                f&
of ._                                                                                                                                                    so                    che        best of my knowledge an f te lief. the Manuf actuart 111.
m pun on . . . a nua ry y 2 ,,, ,_ pg 74 ._. nd st at e shat l
has      s o.nasui ird abis ry.ruip.m                                                                        ni in .n medaru a. with the applic able Subseid sions ishre the luspi rtoe our hi cniplover makes any m arr.mry. espressehi s ern; ly,, e shall be liable in an) un implied, cont a rn-of A9(1. CuJt, f<-c s:,,n                      "
q                                  th signmr ibis sen.fo us.
manner for any personal inguay or properey d.smage or a loss of any kining ils eqinpmr ai d                                                                                                                                                                                                                    ,
ll g 74 i
I  t                            n,,, _,,,,, J a nua ry 2 2                                                                                                                                                                                                                                                                                        '
Wh*5 Commir.sion s                                            m.u.a.i no.,qs.. .,.e n . - .no n ..>
h
                                                          %, . ,,w .,3 l
[w'                                                                                                                                                                                                                                                                                                          .....,
                                                                                                                                                                                  ..m - ,. . _ n.m... _ i,. _ . ,.. .. _ ,i.. ... ..r....
    ;                              r.ne..in          .. . ~ ,,,
                                                                                                                                                                          ,,i.
  .oe
&:es M                                                                                                                                                                                                                                                              .-        .        -
                                                                                                                                                                                                                                                                                                      --..==t.v-1 M"                                                                  .
                                                                                              ..              _m
: p. E' .
s.:                                      .            .
 
i
:                                                                                                                                                    Page 1 (Front) 2                              FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS j                                        As Required By The Provisions Of The ASME Code Section XI I  1. Owner AP&IJEntergy Operations, Inc                                                      Date      04/01/93 j                                                      Nams j        Rt. 3, Box 137G, Russellville, AR 72801                                              Sheet        1                  of          1 44*
  ; 2. Plant        Arkansas Nuclear One                                                      Unit          Two
;        Rt. 3, Box 137G, Russellville, AR 72801                                                JO# 00888288
]                                                    Address                                                    Repaar oryannai an P.O.No., Job No.,sse.
* j  3. Work Performed by AP&IJEntergy Operations, Inc                                          Type Code Symbol Stamp                  N/A j                                                      N=                                      Authorization No .                      N/A
;        Rt. 3. Box 137G, Russellville, AR 72801                                              Expriation Date                          N/A 1                                                    Ad*==
:  4. Identification of System CVCS (2HCB-7) 1
: 5. (a) Applicable Construction Code                  smn              19 71        Edition, S 73'              Addenda, NA                        Code Case l        (b) Applicable Edition of Section XI Utilized for Repairs of Replacements 19                86 1
: 6. Identification of Components Repairs or Replaced and Replacement Components 4
i
      .                                                                                                                                                    ASME l                                                                                                                                                          Code National                                      Repaired,              Stamped Name of              Name of                        Manufacturer            Board      Other              Year          Replaced,              (yes
;      Component            Manufacturer                      Serial No.                No. Identification          Built      or Replacement            or No) 4      3/4" GLOBE -        WESTON                          2554                N/A        2CVC-1099            1974        REPAIRED                YES i      VALVE                IWDRAULICS
                                                                                  "'^
:    \                                                                            "'^
:          N                                                                      =
l N                                                                N/A
: 7. Description of Work REMOVED &. REWELDED BODY TO BONNET SEAL WELD                                                                                                l 4
: 8. Tests Conducted                liydrostatic l          l Pneumatic l      l Nominal Operating Pressure R Other l          l Pressure NA              Psi    TestTemp NA                      F NOTE: Supplemental Sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
(12/82)                          This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 REPRINT 12/91
 
Page1(Back)
FORM NIS-2 (Back) i- 9i Remarks NA Applicable Manufacturet Data Reports to be attached                                                ,
I
                                                        . CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and th                  REPAIR -                conforms to the rules of the ASME Code, Section XI.                                                                    Repaar or Replacement .
Type Code Symbol Stamp                                                                    N/A l
Certificate of Authorization No.                      N/A                    Expiration Date                                      N/A Signed                  A /,                  />                            Date                  32                                ,19 %
I                owner af owners o.aien e. TK ' /
D.B.Lomax-Manager Engmeerms Programs                                                                                                                  ;
l CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State
!    or Province of          Arkansas                  and employed by              Fadtory Mutual Engineering Association                                    of Norwood. MA                                                                              Addp ha                    ed the componentsdescribed in this Owner's Report during the period                10/20/92                        to 7/## igi        .-,,,# M/v/f/                  , and state that to the best of my knowledge and belief, the Owner has performed examinations and tdken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, hvis 4 orimplied, concerning the examinations and corrective measures described in this Owners Report.Furthermore, neither the Inspector nor his. employer shall be liable in eny manner for any personalinjury or property damage or a loss of any kind arising from or connected with this in::pection.
k , C. dMS9                                                    Commissions                      NB-9947, Ark.-1133, "N" , "1" , "A"
    /7                          Wr="a Sipeture                                                            National Board, State Province, and Endorsements V                                J.O. Elhott L
Date        S/3                              19 9 '/
j I
 
t Page 1 (Front)
FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI
: 1. Oner AP&I1Entergy Operations, Inc                                            Date      03/26/94 Name Rt. 3. Box 137G, Russellville, AR 72801                                      Sheet        1              of      1 Ahm
: 2. Plant      Arkansas Nuclear One                                              Unit          Two Rt. 3, Box 137G, Russellville, AR 72801                                      JO# 00889340 Address                                                  RepairOrgamzabanP.ONo JobNo etc.
: 3. Work Performed by AP&IJEntergy Operations,Inc                                Type Code symbol Stamp            N/A Nana                                    Authorization No                  N/A Rt. 3. Box 137G, Russellville, AR 72801                                      Expriation Date                  N/A Addre.
: 4. Identification of System LPSI (2FCB-16 )
: 5. (a) Applicable Construction Code      sun 1              19 77      Edition, S-79              Addenda, NA                Code case (b) Applicable Edition of Section XI Utilized for Repairs of Replacements 19        86 i
: 6. Identification of Components Repairs or Replaced and Replacement Components ASME Code National                                  Repaired,          Stamped i    Name of              Name of              Manufacturer            Board        Other            Year      Replaced,            (yes Component            Manufacturer            Serial No.              No. Identification        Built    or Replacement        or No) 1" GLOBE              TARGET                4                  N/A        2SV-5046            1981      REPAIRED            YES VALVE                ROCK
  \                                                                "
        \                                                          "
              \                                                      =
N
: 7. Description of Work REMOVED & REWELDED BODY TO BONNET SEAL WELD
: 8. Tests Conducted            Hydrostatic l      l Pneumatic l    l Nominal Operating Pressure l        l Other l    l Pressure NA              Psi    TestTemp NA                  F NOTE: Supplemental Sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) informa-tion in items I through 6 on this repon is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
(12/82)                      This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 REPRINT 12/91
 
Page 1 (Back) l FORM NIS-2 (Back) l
: 9. Remarks NA                                                                                                                                                  ;
Apphcable Manufacture's Data Reports to be anached i
CERTIFICATE OF COMPLIANCE                                                                                !
We certify that the statements made in the report are co:Tect and this                REPAIR            confonns to the rules of the ASME Code, Section XI.                                                                  Repair or Replacement Type Code Symbol Stamp                                                                    N/A Certificate of Authorization No.                      N/A                    Expiration Date                                      N/A l
Signed                    [or [.
Owner osDaner's Desiance. Title-Date          S-Z                                      ,19 94, D.B. Lomax - Manager, Engineering Programs CERTIFICATE OF INSERVICE INSPECTION l  I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State l  or Province of          Arkansas                    and employed by                Factory Mutual Engineering Association                              of Norwood. MA                                                                            em havein:px:ted the componentsdesenkd in this Owners Report during the period                10/20/92                        to 7h/M dfN4/IV/M                                  , and state that to the best of my knowledge and belief, the Owner has performed examination's and taken co'rective              r          ' measures desenhd in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed orimplied, concerning the examinations and corrective measures described inthis Owners Report.Furthermore, neither the Inspector norhis employer shall be liable in any manner for any personalinjury or property damage or a loss of any kind arising from or connected with this inspection.
k.O. [ M                  inst Commissions                NB-9947, Ark.-l 133. "N" , "I" , "A" Mtional Board, State. Province, and Endorsements Date      S/3                                19 W l
L
 
Page 1 (Front)
FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI
: 1. Owner AP&llEntergy Operations, Inc                                            Date      03/22/94 Name Rt. 3 Box 137G, Russellville, AR 72801                                      Sheet        1              of        1 Ahess
: 2. Plant      Arkansas Nuclear One                                              Unit          Two                                              l Rt. 3, Box 137G, Russellville, AR 72801                                      JO# 00889341                                                    {
AMress                                                    Repaar Organusuon P.O.No Job No etc.            l
: 3. Work Performed by AP&I1Entergy Operations, Inc                              Type Code symbol stamp              N/A N'a"                                    Authorization No                    N/A Rt. 3, Box 137G, Russellville, AR 72801                                      Expriation Date                    N/A Aheu
: 4. Identification of System LPSI (2FCB-9 )
: 5. (a) Applicable Constmetion Code 8" "I                      19 77      Edition, S-79              Addenda, NA                    Code case  5 (b) Applicable Edition of Section XI Utilized for Repairs of Replacements 19        86
: 6. Identification of Components Repairs or Replaced and Replacement Components ASME Code National                                  Repaired,            Stamped Name of              Name of                Manufacturer          Board      Other            Year        Replaced,            (yes Component            Manufacturer              Serial No.              No. Identification          Built    or Replacement          or No) 1" GLOBE            TARGET                  2                  N/A          2SV-5004            1981      REPAIRED              YES VALVE                ROCK
                                                                  "'^
\                                                                N/A N/A N/A
: 7. Description ofWork REMOVED & REWELDED BODY TO BONNET SEAL WELD 8, Tests Conducted            Hydrostatic l                        l Nominal Operating Pressure l l Pneumatic l                                          l Other l      l Pressure NA            Psi    Test Temp NA                  F NOTE: Supplemental Sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
(12/82)                      This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 REPRINT 12/91
                                  -    _.                ~.
 
l Page 1 (Back) l FORM NIS-2 (Back) l
: 9. Remarks NA Applicable Manuraccuet Data Reports to be anached l
l l
CERTIFICATE OF COMPLIANCE                              .
We certify that the statements made in the report are co:Tect and th                REPAIR            confonns to the rules of the' ASME Code, Section XL                                                                      Repair or Replacement Type Code Spnbol Stamp                                                                    N/A Certificate of Authorization No.                      N/A                    Expiration Date                            N/A Signed                    [
Owner /r ows DamianeMh /
                                        .  !J                                    Date          5 - Z'                          ,19 94 D.D. Lomax - Manager, Engineenng Programs CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of          Arkansas                  and employed by              Factory Mutual Engineering Association                          of Norwood, MA                                                                              Anp haveinspected the componentsdescribed                  '
in this Owner's Report during the period                10/20/92                          to 7MN              N"#Iff/9# , and state that to the best of my knowledge and belief, the Owner has performed examinations and taiEen c6rrective' measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the inspector nor his employer makes any warranty, expressed orimplied, concerning the examinations and corrective measures described in this Owner's Report.Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
l:    h . O. [M                                                        Commissions                NB-9947 Ark.1133, "N" , "I" , "A" g                            gg mm o_ se_. a t                    _,e,a.
Date            6~/3                        19 9e/
l
 
Page 1 (Front)
FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI
: 1. Owner AP&IJEntergy Operations, Inc                                            Date      06/09/93 Name Rt. 3, Box 137G, Russellville, AR 72801                                      Sheet        1                    of          I me                                                                                                              !
: 2. Plant        Arkansas Nuclear One                                            Unit            Two                                                    l Rt. 3, Box 137G, RusselMlle, AR 72801                                        JO# 00892261 Address                                                  Repaar Organizataan P.O.No.. Job No.,sse.              l
: 3. Work Performed by AP&I1Entergy Operations, Inc                                Type Code Symbol Stamp                      N/A                        j N=                                      Authorization No                            N/A                      J Rt. 3. Box 137G, Russellville, AR 72801                                      Expriation Date                              N/A                        l
                                          ^**""
: 4. Identification of System CVCS (2HBB-33 )                                                                                                              j
: 5. (a) Applicable Construction Code          Alse                19 69    Edition, SUPP 1 & 2 Addenda, N/A                                Code Case (b) Applicable Edition of Section XI Utilized for Repairs of Replacements 19        86                                                            )
l
: 6. Identification of Components Repairs or Replaced and Replacement Components                                                                          l ASME Code National                                            Repaired,        Stamped Name of                Name of                Manufacturer          Board      Other                Year              Replaced,        (yes Component              Manufacturer              Serial No.              No. Identification            Built        or Replacement        or No)
COMPONENT              BECHTEL                  N/A                N/A        2HBB-33-H8          E                REPAIRED            NO SUPPORT                                                                                            1972 N/A N/A N/A N/A
: 7. Description of Work MODIFIED SUPPORT
: 8. Tests Conducted              Hydrostatic l        l Pneumatic l    l Nominal Operating Pressure l              l Other l      l Pressure N/A            Psi    TestTemp N/A                        F NOTE: Supplemental Sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) informa-tion in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
(12/82)                      " Ibis Form (E00030) sney be obtained from the Order Dept, ASME,345 E. 47th St., New York, N.Y.10017 REPRINT 12/91
 
i Page1(Back) i
;                                                                                                                                                                          4 i
i FORM NIS-2 (Back) i 1
: 9. Remarks NA Applicable Manufacture: Data Reports to be enached i
k                                                                                                                                                                          l i
4 l
d j'                                  .
                                                          - CERTIFICATE OF COMPLIANCE
,                  We certify that the statements made in the report are correct and th              REPAIR                    confonns to the rules of the                -
.      ASME Code, Section XI.                                                                  Repair or Replacement                                                      4 i
]
    . Type Code Symbol Stamp                                                                    N/A i                                                                                                                                                                          '
Certificate ofAuthorization No.                      N/A                    Expiration Date                                    N/A Signed                  J/ [.                                              Date            6-Z                                    ,19 %
]                Owner or owners Demiansa. Title      /
j                D.B. Innax - Manager, Engmeenng Progranu
;                                                  CERTIFICATE OF INSERVICE INSPECTION -                                                                                  .
!      I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel . Inspectors and the State
,      or Province of          Arkansas                  and employed by              Factory Mutual Engineering Association                                      of Norwood, MA                                                                            w
}
havf iped the componentsdescribed
;      in this Owner's Report during the period                10/20/92                        to #//ff              MC ,I MW/99 , and state that
      .to the best of my knowledge and belief, the Owner has performed examinations and taken c'orrective measures described in this
;      Owner's Report in accordance with the requirements of the ASME Code, Section XI.
;          By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the -
4 examinations and corrective measures described in this Owner's Report . Furthermore, neither the Inspector not his employer 3    shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.                                                                                                                                                          '
J          T . O.      [ //[ O                                        Commissions                NB-9947 Ark.-l133, "N" , "I" , "A" National Board, State. Province, and Endorsemmts 4
  !      Date        S/3                              19 94/
1 l
L
 
                                                                                                                                              - Page 1 (Front)
                          - FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI                                                                    i i
i
: 1. Owner AP&I1Entergy Operations, Inc                                              Date      _
06/09/93 Nasse Rt. 3. Box 137G, Russellville, AR 72801                                        Sheet          1              of        1 ue
: 2. Piant      Arkansas Nuclear One                                                Unit              Two                                                    :
1 Rt. 3, Box 137G, Russellville, AR 72801                                          JO# 00892262 M&ess                                                      . Repair Orgamzauco P.O.No., Job No.,sec.                    l
: 3. Work Performed by AP&I1Entergy Operations,Inc                                  . Type Code Symbol stamp                N/A-Name                                        Authorization No                      N/A                                '
Rt. 3. Box 137G, Russellville, AR 72801                                        Expriation Date -                    N/A um
: 4. Identification of System CHEMICAL & VOLUME CONTROL (2HCB-33)'                                                                                              :
: 5. (a) Applicable Construction Code      Aisc                19 69        Edition, SUPP.1 & 2 Addenda, NA                                  Code Case (b) Applicable Edition of Section XI Utilized for Repairs of Replacements 19          '86                                                              :
( 6. Identification of Components Repairs or Replaced and Replacement Components -
l ASME Code National          .
Repaired,                Stamped        .
Name of              Name of              Manufacturer            Board          Other                Year      Replaced,                  (yes Component            Manufacturer            Serial No.                No. Identification              Built    or Replacement              or No)
COMPONENT            BECHTEL                NA                  N/A            2HCB-33-H6            E          REPAIRED                  NO SUPPORT                                                                                                1972                                                ;
N/A x                                                            =
N/A
                                                                    =
N                                                                                                                                            ;
: 7. Description ofWork MODIFIED SUPPORT                                                                                                                        ,
l 8. Tests Conducted            Hydrostatic l        l Pneumatic l  l Nominal Operating Pressure l-              l l
Other l      l Pressure NA              Psi        TestTemp NA                      F NOTE: Supplemental Sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) informa-tion in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
(12/82)                      This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 REPRINT 12/91          ,
1 j
 
1 l                                                                                                                                                              Page 1 (Back)    j i                                                                                                                                                                              l
:                                                                                                                                                                              1 3.
FORM NIS-2 (Back) j    9. Remarks NA Appucabie Manut ctures osta Reports to tu anached 4
                                                                                                                                                                              )
F 1
1 1
,                                                                CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and th '              REPAIR                    conforms to the rules of the I
ASME Code, Section XI.                                                                      Repair or Replacement 1
Type Code Symbol Stamp                                                                        N/A
,          Certificate of Authorization No.                          N/A                  Expiration Date                                    N/A                              .
Signed                      If I                                                Date          6 -l,                                    ,19 $$
f                    Owner or 0&ner's Douanse. Title        -~/
D.B. Lomax - Manager, Engineering Programs j                                                            CERTIFICATE OF INSERVICE INSPECTION
!          I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State i          or Province of            Arkansas                      and employed by              Factory Mutual Engineering Association                                of a              Norwood. MA                                                                              m A # hav                  ed the componentsdescribed i          in this Owrier's Report during the period                    10/20/92                      to 7/7M dyiy/      JC-VMF/9# ,and statethat
        . to the best of my knowledge and belief, the Owner has performed examinations and talien co'rrective ' measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed orimplied, concerning the
,        examinations and corrective measures described in this Owner's Report.Furthermore, neither the Inspector nor his employer
,        shallbe liableinany mannerforany personalinjury orproperty damageora lossof any kindarising from orconnectedwiththis inspection.
d S. O.      [_/A_                                                Commissions                NB-9947, Ark.-l 133 "N" , "I" , "A" g                                    g                                                                National Board, State. Province, and Endorserneras Date      8!3                                    19 hY
 
i Page 1 (Front)
FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI
: 1. Owner AP&IJEntergy Operations,Inc                                          Date      04/02/94 Name Rt. 3, Box 137G, Russellville, AR 72801                                    Sheet        1              of        1 Addrces
: 2. Plant      Arkansas Nuclear One                                            Unit            Two Rt. 3, Box 137G, Russellville, AR 72801                                      JO# 00892313 Address                                                  Repair Organnahan P.O.No., Job No.,etc.
: 3. Work Performed by AP&IJEntergy Operations, Inc                              Type code symbol stamp              N/A Nanw                                    Authorization No                    N/A l    Rt. 3. Box 137G, Russellville, AR 72801                                    Expriation Date                      N/A Address
: 4. Identification of System LPSI (2FCB-11 )
: 5. (a) Applicable Construction Code      sum                  19 71      Edition, S 72              Addenda, NA                      code Case t
!      (b) Applicable Edition of Section XI Utilized for Repairs of Replacements 19      86
: 6. Identification of Components Repairs or Replaced and Replacement Components AShE Code National                                  Repaired,              Stamped Name of              Name of              Manufacturer            Board      Other            Year        Replaced,              (yes Component            Manufacturer            Serial No.              No. Identification        Built    or Replacement            or No) 1" GLOBE              BORG-                  1919                N/A        2SI-50              1974        REPAIRED                YES VALVE                WARNER
                                                                    "'^
  \                                                                N/A N/A
                                                                    "'^
N
: 7. Description of Work REMOVE & REWELDED BODY TO BONNET SEAL WELD
: 8. Tests Conducted            Hydrostatic l        l Pneumatic l    l Nominal Operating Pressure l        l Other l      l Pressure    NA          Psi    Test Temp NA                  F NOTE: Supplemental Sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) informa-tion in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
(12/82)                      This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 REPRINT 12/91
 
Page 1 (Back) 1 FORM NIS-2 (Back)
: 9. Remarks NA Apphcable Manufacture's Data Reports to be anached l
CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this                                                                              -l REPAL confonns to the rules of the                _
ASME Code, Section XI.                                                                    Repair or Replacement Type Code Symbol Stamp                                                                    N/A                                                                    :
i Certificate of Authorization No.                    , N/A                    Expiration Date                                    N/A                              l Signed                    ],/                    J                          Date          ,$. g                                  ,19 @
Owner or Q4ner's Desinnee. Title" ' /
D.B. Lomax - Manager, Engineering Programs l
CERTIFICATE OF INSERVICE INSPECTION ~                                                                            l I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of            Arkansas                    and employed by            Factory Mutual Engineering Association                                    of Norwood. MA                                                                              ad4# hav in this Owner's Report during the period                  10/20/92                      to 7/7/M Y,-,        gip'ed      the componentsdescribed
                                                                                                                        ,I 4//A/##/              , and state that to the best of my knowledge and belief, the Owner has performed examinations and talien 6rrectiv5 measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed orimplied, concerning the examinations and corrective measures described inthis Owner's Report.Furthermore, neither the Inspector norhis employer shall be liable in any manner for any personalinjury or property damage or a loss of any kind arising from or connected with this                                  i inspection.
l
: 1. O .      [_//m                                              Commissions                  NB-9947, Ark.-I l33, "N" , "1" , "A" g                          inspector's Signature
                                    - J.O. Elliott National Board State, Province, and Endorsements Date      S/3                                  197 Y
                                                                                                                                                            -m  -
 
                      -                -.          . . . - -                      =    -    ..      .                      .    -        - - _ .          _ _ ~ .
Page 1 (Front)
FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI i
: 1. Owner AP&IJEntergy Operations,Inc                                                Date      05/13/93 Name Rt. 3, Box 137G, ~Russellville, AR 72801 -                                      Sheet        1                of          1                                  ,
Am.
: 2. Plant      Arkansas Nuclear One                                                Unit            Two Rt. 3, Box 137G, Russellville, AR 72801                                          JO# 00893120 Addras                                                                                                                    '
Repair Orgamzation P.O.No., Job No., esc.
: 3. Work Performed by AP&I/Entergy Operations,Inc                                  Type Code Symbol Stamp                  N/A N=                                        Authorization No                        N/A                                    -
Rt. 3 Box 137G, Russellville, AR 72801                                        Expriation Date                          N/A Am.
: 4. Identification of System SPARE VALVE (STOCK)
: 5. (a) Applicable Construction Code sm.m                          19 77    Edition, S-79                Addenda, NA                          Code Case (b) Applicable Edition of Section XI Utilized for Repairs of Replacements 19            86
: 6. Identification of Components Repairs or Replaced and Replacement Components                                                                                    ,
ASME Code National                                      Repaired,                  Stamped Name of              Name of              Manufacturer              Board        Other              Year        Replaced,                  (yes Component            Manufacturer              Serial No.                No. Identific'ation          Built    or Replacement              or No) 1" GLOBE              TARGET                80                    N/A          2SV-0205            1992        REPAIRED                    YES VALVE                ROCK N/A N/A N/A l
                    \
: 7. Description ofWork REMOVED & REWELDED BODY TO BONNET SEALWELD
: 8. Tests Conducted            Hydrostatic l            l Pneumatic l  l Ncminal Operating Pressure l          l                                                  j Other l    l Pressure NA                Psi      Test Temp NA                    F
                                                                                                                                                                      ]
NOTE: Supplemental Sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) informa-tion in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
(12/82)                      This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 REPRINT 12/91 l'
1
 
i l
Page1(Back) m I
1 FORM NIS-2 (Back)                                                                                )
: 9. Remarks NA 4pMic Manufacture's Data Reports to be anached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and th              REPAIR                  conforms to the rules of the -
ASME Code, Section XI.                                                                  Repair or Replacement
- Type Code Symbol Stamp                                                                  N/A Certificate of Authorization No.                        N/A                  Expiration Date                                  N/A Signed                  J./ I                    />                        Date          5. F, . M                              ,19    94 Owner or ywner's Desianos. Title" D.B. Immax - Manager, Engmeermg Programs CERTIFICATE OF INSERVICE INSPECTION -
1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of          Arkansas                      and employed by            Factory Mutual Engineering Association                              of Norwood, MA                                                                          ma# haveinspected the componentshJ4 in this Owners Report during the period                  10/20/92                      to 7/7/rv f//fe#"f </lN/W ,and state that to the best of my knowledge and belief, the Owner has performed examinations 'and taken corrective ' measures described in this Owner's Report i:t accordance with the requirements of the ASME Code, Section XI.
Bysigning tluscertificate neitherthe Inspectornorhis employer makes any warranty, expressed orimplied,concerningthe examinations ar.d corrective measures described in this Owners Report.Furthermore, neither the Inspector norhis employer shall be liablein any manner for any personalinjury or property damage or a loss of any kind arising from or connected with this inspection, k . O . [ /> >                                                Commissions                NB-9947, Ark.-l133, "N" , "I" , "A" g                        Inspector's Signature                                                  National Board, State Province, and Endorsements J.O. Elhott Date        S/3                                19 9 8/
 
l Page 1 (Front)
FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI
: l. Owner AP&l1Entergy Operations, Inc                                              Date      01/07/94 Name Rt. 3, Box 137G, Russellville, AR 72801 Sheet        1                of        1 Ahm
: 2. Plant        Arkansas Nuclear One                                              Unit            Two Rt. 3, Box 137G, Russellville, AR 72801                                        JO# 00893805 Address                                                    Repair Orgaruzauan P.O.No.. Job No.,etc.
: 3. Work Performed by AP&I1Entergy Operations, Inc                                  Type Code S3 mbol Stamp                N/A N=                                      Authorization No                      N/A Rt. 3, Box 137G, Russellville, AR 72801                                      Expriation Date                        N/A Ahss
, 4. Identification of System LPSI(2GCB-8 )
I
' 5. (a) Applicable Construction Code SECT nl                      19 71      Edition, S-72                Addenda, NA                        Code case (b) Applicable Edition of Section XI Utilized for Repairs of Replacements 19        86
: 6. Identification of Components Repairs or Replaced and Replacement Components ASME Code National                                      Repaired,              Stamped Name of              Name of              Manufacturer            Board        Other              Year        Replaced,                (yes Component            Manufacturcr              Serial No.              No. Identification        Built    or Replacement            or No) 1" GATE              BORG-                  920                N/A          2SI-1036            1973        REPLACED                  YES VALVE                WARNER 1 GATE              WESTON                  1701                N/A          2SI-1036            1974        REPLACEhENT YES VALVE                HYDRAULICS N/A N/A N/A                                                                                j
: 7. Description ofWork CUT-OUT & REPLACED VALVE
: 8. Tests Conducted              Hydrostatic l        l Pneumatic l    l Nominal Operating Pressure l          l Other l      l Pressure NA              Psi    TestTemp NA                      F NOTE: Supplemental Sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
(12/82)                        This Form (E00030) may be obtained from the Order Dept., AShE, 345 E. 47th St., New York, N.Y.10017 REPRINT 12/91
 
. -              - . .                        .        - . - - . . . .                  . . -          -        - - -                    ....-              -  ...    ~
l Page 1 (Back) l I
FORM NIS-2 (Back)
: 9. Remarks NPV-I MANUFACTURES DATA REPORT ATTACHED FOR REPLACEMENT VALVE                                                                                                    :
Applicable Manufadurei Data Reports to be anached i
t a
f CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are cmat and th                        REPLACEMENT confens to the mies of the ASME Code, Section XI.                                                                                Repair or ! Ri &t                                                  '
Type Code Symbol Stamp                                                                                N/A
    . Certificate ofAuthorization No.                                N/A'                      Expiration Date '                                N/A Signed                  j./ [                                                              Date          5-t                                    ,19 %
Owner /r Owner's Desianee. Tstle                                                                                                                                i D.B. Lomax - Manager, Engineering Programs                                                                                                                        I
:),
                                                      ' CERTIFICATE OF INSERVICE INSPECTION                                                                                    l I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of            Arkansas                          and employed by -                  Factory Mutual Engineering Association                              of Norwood. MA                                                                                          p As have i              ed the componentsdescribed in this Owner's Report during the period                          10/20/92                          to 7/7/M '/ Ng+' MW/W ei                        , and state that to the best of my knowledge and belief, the Owner has performed examinations and tafcen co'rrective' measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed orimplied,concerning the examinations and corrective measures described in this Owner's Report.Furthermore, neither the Inspector norhis employer shallbe liableinany mannerforany personalinjury orproperty damageora loss'of any kindarising fromorconnectedwiththis inspection.
k , C. [ ./24 9                                                          Commissions                    NB-9947. Ark.-Il33, "N" , "I" , "A"
(/                          . Inspector's Sipature J.O. Elliott National Board, State. Province, and Endorsemeras Date            5/3                              19 9a/
 
A                                -
ASI-/o54 sfyiyet FulBI NI'V.I nt ANilFACMiltF.itt flATA lEl4MIT FOtt NtJCI.F. Alt l'tslPs oft VALVES
* A. Itegelred by the 1%s lo. .f the ASIF. Code Itale.                                                              . - -
_ ,,          n..-..-                          .. . . .
A42494 g g1      g.c  .,,4 Qeston flydraulics,_ 7500                        Tyrone _ Ave. . Van Nuys. CA o,4,, g s ae ... .e um..ewiw=
in O.,, Box,396,5,,, San Franeisco                              o,4,, g.,    4600-M-212,4-B_
: 2. Ms f*es*cd I"II-* etytel Power Corpz,w==                      ,P g      4 444 ..                                      cA A rka ns a a Powo r,,s,nd,_Li.,,gh_t, .,Co. saga ay g o ,,                                  ,
4 g,,,y .g pg .                  Little Rock. Arkansas Part Number 70080 1 Inch Gate Valve Tag No. 1" CCA-07 g p.mp a vol IJeuttic.tio.
serial Numbers 1550-1545, 1695-1703 (25.ns.m                                          Valves).            .n 4..a...e, to .e e. wee,es      .s        in s Weaton Hydroulics 70080                  _p,,,,,,4 g
.        (a) Deewi.s No.-                                                            .
m s..i        .i no.,4 s
                                                                                                          '          (  .      .
3600                  p.;_                100              *y,      ,.
: 4. De e13. Co.ditio.s                        gren .:                                    (T            a =3 I
d wwkm.. ship complice with ASME Code 5ecei IIL Close 7, ne materi.6, desig., constr.c.io.,
gg;i;              197_1            - , Adocode Dei,_ Sununor 1972 - . Case No.
u      two==                    s. wn.
u.,e n..                            u        .: se.<. no.
;          (a) Cassiass SA351-CF8M
;                  ,pate - Code 1A,51                                                                            Rex Precision l                  ___qs_s_t_ing - 70303                                                                          reston Ilydraulics Machined - 70408
?
(b) F or pi.a s                                                                                                                                                                          l
_ Body - Q.gd3_ JA.36, 1A40B                              SA182-F316                                                                                                .
1AD. lA57                                                            Pacific Force i
For.gi.gg. - 703_07                                                                      Weston Ilydraulics l
Machined - 70336                                                                        Weston Hydraulics                                                                i Body Assy.          -    70329                                                                                                                                            !
i Bonnet - Code 1A46                                        SA182-F316 Jorgensen Co.
Forge,d Stock Weston Hydraulics Machined - 70324                                                                                                                                                  s, j
i s%" . I t". m int ==.it
: i. ii. . t, t, s. ..a
          *s.,e s ..w i.s ehui      i tw. .t neie, et.i n.. .,4,..i.s. may 6. ...a ,.. 44 4 (i)e .in                                                                                                :
                                                        .un .awa,      d  ta)  .wh      en.. se    . bu.e        . ber t h..i. a. a.w<.4.i i.e .t aw. s==.
se    sw. 4.i. we.ri    se s  :.4.d 4
                                                                                                                                                                                                  . 1 i
N w w. - .            --              \
g o
 
a                                                  .
FtM01 NPY.1 (keek) es.ae ..                          m        ..
es. .....      ..w is = ss..                                  !
                ~
(e) nalains                                                                                                                                                                      O (d) Othe, Parte                                                        _
b                                                                                  .
  )
* i 3
5400-5450                _ p.i, 4  S. llydeoesuie se,.
3                                                                .              Cell 1111CA110N OF DEMGN E1400 3                                                              on Hydr _e.ulles. 7500                a Tyrone n
Ave.
n      . Van a  Mu.m CA  =
Detiam infamatles em Gle uwes t.4                                      h (t} prog. tag.ka.e Terms Reg.N 25165.
        $sesse smalysis, report om file as 1
Desiga specificesions eersified by__B.
H.      Isonard. Jr.                                                            . Reg.No.13790 (I) peet. Eng.5:ue.f4
        $ssess samty sin report certified by _
R. L. CiterleY
  ")                                                                                                                          ----
(1) Sisasive, noe required. I.ist name only.
7                                                                                                                                        ,
Te cevilly that she asasements snade in this repoet art correct.
74                          Weston Hydrevlies                          By  C.f 'b January 23 _ g,                                  Sis. ,4 Das,_                                                                                cw. # we,,
533              _ e,p;,e . December 18. 1975 h          Certificeie of Aviheeisation Nn.
a CEIL 1111CATE OF NI0l' INSI'EC110N l
i
+.
j
: l. ake endersigned. balding a entid coensission                                                            issued
_ ..a e.pt,y,a by__
Dept.
by the of Bidr.
National  & Safetv Doesd al Dollet and Pse Ca li fo rnin j          and/ c she saue of Peo.isce of _                                                                        hace inspected the epipment desesibed in this Date j          ef_            Qi.tlo f)1 Angchs.4                          7            , and sine thu sa she bess of my knowledar and belief, the Llanufsc<= ret Repori      n J_anuary 23                          39 ssed or implied          concern.
boa consieucted                        this equipment                in aescrJance wi In ihe applicatJe Sehmections                                      of ASME kle is anyCode. Seesion Ill.
signina shis certific aec, sciehet she Inspe esos nor his employes makes any warraacy, esste
:            inaDyihe eqwipencat described in sl.is Data Repost. Fe.shermose.                                                                      neieher frase or connected wish thisthe          tospeceot nor his emple inspection.
l            manner for sny personal ingwry or property damage o# a loss of any kind arising 3
1 i
j                                                                                                                                              ,,
January 23                                  3,_74                                                                                  .. .
j            naie _                                                                                                                                                    .
                              /8                        [                [                        - Cosweis sion s O
                                                                                              .....,....a....-..................,
            ...........m, i                                                                                  _
4
 
Page 1 (Front)
FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI
: 1. Owner AP&IJEntergy Operations, Inc                                            Date      05/13/93 Name Rt. 3, Box 137G, Russellville, AR 72801                                    Sheet        1              of          I l                                        Addrem
: 2. Plant      Arkansas Nuclear One                                            Unit            Two R2. 3, Box 137G, Russellville, AR 72801                                      JO# 00893882 Address                                                Repair Orgamzatson P.O.No., Job No etc.
N/A
: 3. Work Performed by AP&I1Entergy Operations,Inc                                Type Code symbol stamp Nan =                                  Authorization No                    N/A Rt. 3. Box 137G, Russellville, AR 72801                                    Expriation Date                      N/A Addrem 1
: 4. Identification of System BS (2GCB-69)
: 5. (a) Applicable Construction Code srcr.ni                    19 71      Edition, S-72              Addenda, NA                          Code Case (b) Applicable Edition of Section XI Utilized for Repairs of Replacements 19      86
: 6. Identification of Components Repairs or Replaced and Replacement Components ASME Code National                                  Repaired,                    Stamped Name of              Name of              Manufacturer          Board      Other            Year        Replaced,                      (yes Component            Manufacturer              Serial No.              No. Identification        Built    or Replacement                  or No) l' GATE              BORG-                  350                N/A        2BS-1070B          1973        REPLACED                      YES VALVE                WARNER 1" GATE              WESTON                  863                N/A        2BS-1070B          1973        REPLACEMENT YES VALVE                HYDRAULICS N/A N/A N/A
: 7. Description ofWork CUT-OUT & REPLACED VALVE
: 8. Tests Conducted            Hydrostatic l        l Pneumatic l  l Nominal Operating Pressure l        l Other l    l Pressure NA              Psi    Test Temp NA                  F i
NOTE: Supplemental Sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) informa-tion in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
(12/82)                      This Form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N.Y.10017 REPRINT 12/91 l
l
 
Page1(Back)
FORM NIS-2 (Back) 1
: 9. Remarks NPV-1 MANUFACTURERS DATA REPORT FOR REPLACEMENT VALVE ATTACHED Applicable Manufacture's Data Reports to be anached
                                                                                                                                                                ]
I l
CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this          REPLACEMEbfr - conforms to the mies of the ASME Code, Section XI.                                                                    Repair or Replacement Type Code Symbol Stamp                                                                    N/A Certificate of Authorization No.                    N/A                    Expiration Date                                    N/A Signed                    I          ,                                      Date            S - 7.                                ,19 9[
Owner or Wwner's Desianne. Title "/
D.B. Iemax - Manager, Engineering Programs CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of          Arkansas                  and employed by              Factory Mutual Engineering Association                                of Norwood, MA                                                                            A0# ha,veinspected the components described in this Owner's Report during the period                10/20/92                        to 7MI#3-/F+' #dtv/9v                              , and state that to the best of my knowledge and belief, the Owner has performed examinations and fakerfcorrective m'easures described in this                                '
Owner's Report in accordance with the requirements of the ASME Code, Section XI.                                                                              l By signing this certificate neither the Inspector nor his employer makes any warranty, expressed orimplied, concerning the examinations and corrective measures described in this Owner's Report.Furthermore, neither the Inspector nor his employer                                    ;
shall be liable in any manner for any personalinjury or property damage or a loss of any kind arising from or connected with this inspection.
1 k , o.      [M                                              Commissions                  NB-9947, Ark.-1133, "N" , "1" , "A" g                          gg                                                                      NatioM Board, State. Province, and Endonernesas Date        5/3                            19 '/ '/                                                                                                        j
 
                                                                                                                                                                                                                                                                                                            ;7BS- Je 70B                            k shy w I l.E til l'lNI'S Olt V AtJE5' Fult\t Nt'V.I \1%IIFMll4'lli:sts' IITTA ItI-;l'ultT Full M:
A. Reigelect I., the l'imi inea cf abe A4tF. ( Je Itele.                                                                -      . ___.._:
                                                                                                                                                                                                                                                  - - ~ - - -                  .ma :.~ __
                                                                                                                                                                              . 3 : ~..
                                                                                                                                                                                            .v a r.-v ,..v ,_ - :n u .
                                                          ,_.____v,_                            _
A42496
: g. u. tni.eeJ by_I'.sto:4,                                                                                                            in      6 u ... 4 w    flydgagi,os  .r..      us                    ,, ,7800_Tyrono, Ave . Yan_Nuybs 398L8an Francisao_ o,4,, y,, _8600-N-2114-B
: 2. Wea.f.ceweJ far MIN.pr Co,,t,2f,,                                                                                                            sw . .ad Mf_,    A.a*...:Bog,Califozwis O                                                                                                        A_r.,            k ans.as,,h_r. s_g_tf,gh,t ,Co,mpe_ny
                                                                  ). 0=see g                                                            4. Lee ii.e et t' tame _ Little _ Rock.1Mrka_a_sas                                                                                                                    Ind_Ogir Yalve Tar No.1" CCA-@r 0
v '' s. P.er e Valve ide.eIficsilea.BUL"4_)lWLabe.r.J,.QSO                                                                                                                                                                                                                                                                                        ,
                                                                                                                                                                                                                                                                                                                                      --                j 846 - 862, 864 - 871 (25 Valves)
                                                                                                                                                                                                                                                                        .. a.. e S                                                                            Serist Ntsrbere                                                                                            cma.e      ,i,i l  .e = ,.ie. s.                wn .                                                                                                    i I
G Weston Eydraulies 4                                                                                                                                                                      70080                        _ p,,,,,,.a g g.3 oJ.;.g N _                                                                                                              -
O                                                                                                                                                                                      i.                          - -              -
                                                                                                                                                                                                                                                                            -                                                                                l gn usdemas t>eard No._
* l 3600                        _ ,,g
                                                                                                                                                                                                                                                *100 of A Deelsa Caadiet ps 2                                                                                                                                          (T.wpe.uropel (Pres.w.)_
i    til. Close _I O                                                    7. The material. Jealsa. <*aser=<ii.a. **d =akaamship c ctie. .ish AshfE Code Sect .e
                                                                                                                                                                                            -, Addenda Det,_8?numer '72_                                . Case No._
1971 gdi1 a  .m .
m.e i.: e,.e. we.                            wenswiew asme w..
                                                                              ~ (s) ca.siass
                                                                                                                                                                                                                    ._fA351-CJ1tM _
_cate - Code 1A43_,._1A5)                                                                                                                          mar Precision
                                                                                                            ._._Cas. ting - 70393                                                                                                                              [ggtpp gyAntg} igg
___ Ma ch ined_ _. T04, 6_.                                                          0      _ _ _ _ _      _ _ _ _ _
                                                                                                                                                                                                                                                                                                                                                .m ab 7- s i. , .
_ g is> .r sj s____                _
                                                                                                                .D9dy - cc: sis _JAion _
rorginr - 7030L Besiite arre restan_Rydtmulism o                                                                                                                                          Machined - 70336_ _                                                              _
feston.Jirt ts.E1icsi
___Desty_Ata'.r._ _ ff3.2,9                                                                                                      _
1
                                                                                                                  .Ji9Jm9t __ ppde._1446 _                                                                      _._ __B}83-M1J_                                Jorg.gnsen_Qp..
70rgod..Stook.
(es.t.oA.Hydtstulist h Vff                                                                                                                          _Jinchined.. 70324 _                                                                      __._        _ _
I L
et~,cnist--.as                  s.        .e.a.s.          a 8
                                                                                              .w_r    .e ,,,,se.datene,a snae. so. am e.n...s.r                                            ..au..... n.. 4,.w
                                                                                                                                                              ,,,we s. sa.i.e.4 .us .6 :. d m enn .n,.e u . n=ed nad
                                                                                                                                                                                                                                    ,n.
                                                                                                                                                                                                                                                                        ===t= .t ah .a u . 4 4 m ue .iinu t==.
 
(g_gg- u_ _ _--
l.* tilt \1 Nt'V.I                            (linrL)                                                                                                          ,
I l
8 '-* .
                                                                                                                                          '            w .a.f ** * *
* _
i u..... .            mi... . w ..              ,,_
u i ,, . .                                                      .-,
                                                                                    - - - ~ * ~ ~ ~ ~ ~ " " " * ' -"-. .-                                                            ..
(t) l.l_a_it18_8--- _ _ . . . _ _ _ _ . - ,_ _ _ _ _.
6
                                                        . _ . _ _                                                                                                                                                                                      w.    .
i ..
(
(43 ,,her6 Peres                                    _ _ . _ _                    __.                            _
)                  _                                                        -
n..
j                    -
v.
u p                        _
b ,.                          ,e ,e.._
M*-M"                        -- p.i.
      ,,,d CERT 1HCATION OF DEt4GN 5                                                                                                                                                                                                      cs. 91400
'e                                                                                                                          7500 Tz.pne Ave.. Van Ntrys u 5) pets,i.f-.mi.e                                                                                                            750,0,,__Tg_ Ave. . Yes A;. Cs. 91409 Texas _ Res
'E) r.se ., Yeston Nydraul,ics.,,_Serise                    B.+. 5. , IAonerti, Jr.
f
_ g g ) p,.g,smalysis  g.g m.,
_ g33 p, t,g.g,we, Caltf g,,,y.,J3J_90,                i repers en file se _
Desima specifiewiens eenified by                        R. L. Citerlef                                                                                                                            .s g      54rese analyals report cessified by fy, g      (1) Sis ...i non omis.J. Liss name a"'-
we ,,..iry 6. 6, u.ie.c.i. =ade i= aia <cea$ =e <
Vost,on,_piirsuj_J es                                      _ py__        b'b 16 November _ g9 73                        Siped                                    cu s.ein.<s Deer                                                                                                                                            18. 1975
                                                    .        533_      -
                                                                                                        ,,P;,,, December                                                                                                                      .__
c,n;r.cese of A=4ar.isainen N .                                                                                                                                              .
CEltTIRCATE OF Sil0F INSI'ECTION i      l Doard of Boller and Pressere Yessellaspersons_                                                          l Estete                                          l 1, the modersiped, holding                    Callfornis                  e valid easvois**nne isseed by the Nat ona- ip                                                                                  sad employeJ by.EC.
sed /.c abe 5ssae el Pse,ince d
* __ g ,,;.,p ,gg,g h , , p p. ,,, 4,.e,;g,4 ;, e , . .                                                            ;
                                                                                                                                                                                                                                                                    )
h ties of my knowledge and belief, de blumf acturer MJity of* Io,,n,, Angeles                                                                                                                                                                                                                                I Reyevi ee .I.O. Koycabpr,,__39,,,73,,__,                                                                                          Subsections
                                                                                                                                      ,,,a ,,,,, shat      kes any      se  of sASME warsanty,e espressedCode. Secties              lif. concern.
ev IsapfieJ,                                  ;
bas cansas.csed die egvipewes is se creJaace irisk                                                                                            heshelaspectorapplicalJe  not has employev shall be liebte in any ing she e quipenest de.4 riheJ                                                                                  f I any  ja kind    shie        flers maisies              frams    Repare.
or conneceed          Fescherrnase, sieb this inspection.acnh mannet for say petoonal iajery or pop <<sy Jamage os a uss <
_ _ 3 9,7,_3 16 Noyember p,,,            _                                                                                                                                                                      ,.i A- w                        ,-.-.-              .
                                                                                                                            ~ . .!- .                          ....                s -.      gf.e.. . - s..,                                      e 88 T* 3"'I yy, g.,. gg af) la ebastnsble rese the Asus,345 E. 47sb 8t 8fe* Y*'t.
pytased is U.S.A. (6/f ff
                                                                                                                                                                                                          ..n -.,. o,,,y,y,pg
 
i i
Page 1 (Front) i                              FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI
],
I                                                                                                                                                              i i                                                                                                                                                              I J  1. Owner AP&I1Entergy Operations, Inc                                              Date      04/22/94                                                      I j                                            Name Rt. 3, Box 137G, Russellville, AR 72801                                        Sheet        1                of        1                              l i                                        Ad*==
l 2. Plant          Arkansas Nuclear One                                            Unit            Two j      Rt. 3, Box 137G, Russellville, AR 72801                                          JO# 00894157 Addrums                                                      Repaar Orgamzaban P.O.No., Job No.,etc.
: 3. Work Performed by AP&llEntergy Operations, Inc                                Type Code Symbol stamp                  N/A j                                          Name                                        Authorization No                      N/A j    Rt. 3. Box 137G, Russellville, AR 72801                                        Expriation Date                        N/A
                                          ~
l
: 4. Identification of System M.S. ( 2 EBB-1 )
: 5. (a) Applicable Construction Code        smu                  19 71      Edition, S-73                Addenda, 1574                      Code case
]
l      (b) Applicable Edition of Section XI Utilized for Repairs of Replacements 19          86
!  6. Identification of Components Repairs or Replaced and Replacement Components 2                                                                                                                                                ASME Code l                                                                        National                                      Repaired,            Stamped l      Name of                Name of            Manufacturer              Board        Other              Year -        Replaced,            (yes j    Component              Manufacturer            Serial No.                No. Identification          Built      or Replacement          or No) i
,    8 GLOBE                CROSBY                N58090-              N/A        2PSV-1003            1979          PARTS                  YES
. VALVE                                        00-0007                                                              REPLACEMENT
                                                                        "'^
!  \                                                                  "'^
!        \                                                              "'^
;                \                                                    N/A
, 7. Description ofWork REPLACED NOZZLE AND DISC INSERT
: 8. Tests Conducted            Hydrostatic l      l Pneumatic l      l Nominal Operating Pressure l            l
)
Other l    l Pressure    N/A            Psi    TestTemp N/A                      F
:      NOTE: Supplemental Sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) infonna-
!      tion in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is                          I recorded at the top of this form.                                                                                                                      l 1                                                                                                                                                              !
(12/82)                      This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 l
1 l                                                                                                                                  REPRINT 12/91 4
 
1 i
1
;                                                                                                                                                  Page1(Back) k i
FORM NIS-2 (Back)
: 9. Remarks REPLACED NOZZLE INSERT AND DISC INSERT
,                                                                appuc.w. unmrutures rasa n. para a t. .u.a.d i      NEW NOZZLE INSERT S/N N91560-36-0019 1      NEW DISC INSERT S/N N91562 0033 1
1 j
!                                                      CERTIFICATE OF COMPLIANCE' l              We certify that the statements made in the report are correct and this      ffp/ agggpr confonns to the rules of the ASME Code, Section XI.                                                                  Repaar or Replacement 5
1 Type Code Symbol Stamp                                                                    N/A
{
Certificate of Authorization No.                      N/A                      Expiration Date                              N/A l  Signed                    .            J                                      Date        hasp ,93                                  ,19 1              Owns /or Owner's Desisnee. TitW                                              ,y i            D.B. Lomax - Manager, Engmeenng Programs
;                                              CERTIFICATE OF INSERVICE INSPECTION -
7  I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of          Arkansas                  and employed by                Factory Mutual Engineering Association                        .
of l        Norwood. MA                                                                          dK# haveinspected the componentshd4 i  in this Owner's Report during the period                10/20/92                        to7//Av''#/X/PF MM/Fv                              , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective ' measures described in this
;  Owner's Report in accordance with the requirements of the ASME Code, Section XI.
i        Bysigning thiscertificate neitherthe Inspectornorhis employer makes any warranty, expressed orimplied,concerningthe examinations and corrective measures described in this Owner's Report.Furthermore, neither the Inspector nor his employer                                  ;
j  shall be liable in any manner for any personalinjury or property damage or a loss of any kind arising from or connected with this inspection.
l l
)    9 . C.          28> zh                                              Commissions              NB-9947, Ark.-1133, "N" , "I" , "A" z
g                            pggurs                                                                National Board, State Provina, .nd Emdorsemesas Date    (, /42 3                          19 M e
 
l
                                                                                                                                                      \
Page 1 (Front)  '
FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI
: 1. Owner AP&I1Entergy Operations,Inc                                          Date        04/22/94 Name Rt. 3, Box 137G, Russellville, AR 72801                                    Sheet        '1            of        1 Addrum
: 2. Plant        Arkansas Nuclear One                                            Unit            Two Rt. 3, Box 137G, Russellville, AR 72801                                        JO# 00894157 Address                                                  Rapair Ory=ae P.O.No Job No., sac.
: 3. Work Performed by AP&IJEntergy Operations, Inc                              Type code symbol stamp              N/A Name                                    Authorization No                    N/A Rt. 3. Box 137G, Russellville, AR 72801                                    Expriation Date                    N/A Adorm.
: 4. Identification of System M.S. (2 EBB-1 )
: 5. (a) Applicable Construction Code      sum                  19 71      Edition, S.73                Addenda, 1574                Code case (b) Applicable Edition of Section XI Utilized for Repairs of Replacements 19      86                                                      ,
: 6. Identification of Components Repairs or Replaced and Replacement Components ASME Code  .
National                                  Repaired,            Stamped Name of              Name of              Manufacturer            Board        Other            Year      Replaced,              (yes Component            Manufacturer              Serial No.              No. Identification        Built. or Replacement          or No) 8" GLOBE            CROSBY                  N58090-            N/A        2PSV-1003            1979      REPLACED              YES VALVE                                        00-0007 8" GLOBE            CROSBY                  N58090-            N/A        2PSV-1003            1979      REPLACEMENT YES VALVE                                        00-0009
                                                                          ^                                                                          I N                                                          "'^
N/A
: 7. Description ofWork REMOVED EXISTING VALVE AND REPLACED WITH SPARE VALVE l
: 8. Tests Conducted            Hydrostatic l        l Pneumatic l    l Nominal Operating Pressure lXl                                              I Other l    l Pressure 1000            Psi    Test Temp 545                  F                                    l NOTE: Supplemental Sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) informa-tion in items 1 through 6 on this repon is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
  .(12/82)                      This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 REPRINT 12/91 l
                              .                                                                                              _                      i
 
                                                                                                                                            ' Page 1 (Back)
I FORM NIS-2 (Back) l i
1
: 9. Remarks THESE RELIEF VALVES ARE REPLACED EVERY REFUELING OUTAGE Appucable M-dW Data Rapwu to to anM                                                            l NPV-1 MANUFACTURERS DATA REPORT PREVIOUSLY PROVIDED i
1 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this        REPLACEMENT conforms to the mies of the ASME Code, Section XI.                                                                Repair or Replacement Type Code Symbol Stamp                                                                  N/A Certificate of Authorization No._                    N/A                    Expiration Date                                N/A Signed                      /              f)                                Date        ha,,p g)/                              ,19 9d ownn4rowner Deirnse. e    Title /
D.B. Lomax - Manager, Fngmeermg Programs j
                                                                                        /
CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of          Arkansas                  and employed by                Factory Mutual Engineering Association                      .
of Norwood. MA                                                                          and/ haveinspected the comporutsdesenhd in this Oncr's Report during the period                10/20/92                      to 7///W ddFf' 9/'M/99 ,and state that to the best of my knowledge and belief, the Owner has performed examinations and tdken corrective ' measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.                                                                              I Bysigning thiscertificate neitherthe Inspectornorhis employer makes any warranty, expressed orimplied,concerningthe examinations and corrective measures described inthis Owner's Report.Furthermore, neither the Inspector norhis employer shallbe liableinany mannerforany personalinjury orproperty damageora lossof any kindarising fromorconnectedwiththis inspection.                                                                                                                                                  ,
I
: 9. C. [                                                          Commissions              NB-9947, Ark.-1133, "N" , "I" , "A" '
(f impactors signature                                                  National Board, State Province, and Endorsements J.O. Elhott Date L J2,;L                                  19 C) 4
 
i Page 1 (Front)
FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI
: 1. Owner AP&I1Entergy Operations, Inc                                            Date      06/29/93 Name J    Rt. 3, Box 137G, Russellville, AR 72801                                      Sheet        1              of        1 Aha 4
: 2. Plant        Arkansas Nuclear One                                            Unit            Two Rt. 3, Box 137G, Russellville, AR 72801                                        JO# 00894219 i                                        Address                                                  Repair Orgamzauon P.O.No., Job No.,etc.
: 3. Work Performed by AP&I1Entergy Operations,Inc                                Type Code Symbei Stamp                N/A N=                                      Authorization No                    N/A Rt. 3. Box 137G, Russellville, AR 72801                                      Expriation Date                      N/A Aha 4
: 4. Identification of System GASEOUS RADWASTE (2GCB-7)
: 5. (a) Applicable Construction Code sum                        19 71      Edition, S.73                Addenda, NA                      code case (b) Applicable Edition of Section XI Utilized for Repairs of Replacements 19        86
: 6. Identification of Components Repairs or Replaced and Replacement Components ASME Code National                                    Repaired,              Stamped Name of              Name of              Manufacturer            Board      Other              Year        Replaced,              (yes Component            Manufacturer              Serial No.              No. Identification          Built    or Replacement            or No) 1" GATE              BORG-                  2450                N/A          2CV-2428            1975        REPAIRED                YES VALVE                WARNER
                                                                      "'^
  \                                                                  "'^
l N                                                            N/A N/A
: 7. Description ofWork REMOVED & REWELDED BODY TO BONNET SEAL WELD
: 8. Tests Conducted            Hydrostatic l        l Pneumatic l    l Nominal Operating Pressure l          l Other l      l Pressure NA              Psi    TestTemp NA                    F NOTE: Supplemental Sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
(12/82)                      This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 REPRINT 12/91
 
Page 1 (Back) l i
1 Y
FORM NIS-2 (Back)
. 9. Remarks NA Apphcable Manuracturch Data Reports to be anached i
I                                                                                                                                                                        ,
d 1
,                                                      CERTIFICATE OF COMPLIANCE i              We certify that the statements made in the report are correct and th                  REPAIR                conforms to the rules of the j  ASME Code, Section XL                                                                    Repair or Replacement                                                      ,
4
* Type Code Symbol Stamp                                                                    N/A Ccitificate of Authorization No.                      N/A                    Expiration Date '                                N/A Signed                    31 A            -'
e                          Date          $E                                    ,19 - T$
owner orpwners Desianoe. Tide D.B. Lomax - Manager, Engineering Programs CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of            Arkansas                  and employed by              Factory Mutual Engineering Association                                of Norwoodi MA in this Oncr's Report during the period                  10/20/92                      to #f/ W have    dj  - - , ,
ed the componentsdescribed g I + I#f9A/ , and state that to the best of my knowledge and belief, the Owner has performed examinations and tak'en corrective' measures described in this Cwner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed orimplied, concerning the examinations and corrective measures described in this Owner's Report.Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personalinjury or property damage or a loss of any kind arising from or connected with this inspction.                                                                                                                                                          '
J
: k. O. [.// M                                                  Commissions                    NB-9947, Ark.-l 133, "N" , "I" , "A" g                          Insggp                                                                  Nanonal Board, State. Province, and Endorsemeses Date      S/3                                19 't '}                                                                                                              l l
l
                                                                                                                                                                      \
 
Page 1 (Front) l                              FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI
: 1. Owner AP&I1Entergy Operations, Inc                                              Date      03/23/94 Name Rt. 3, Box 137G, Russellville, AR 72801                                        Sheet        1              of          1 Ama
: 2. Plant        Arkansas Nuclear One                                                Unit            Two Rt. 3, Box 137G, Russellville, AR 72801                                          JO# 00898455 Address                                                    Repair Orgeruzation P.O.No., Job No., sic.
: 3. Work Performed by AP&IJEntergy Operations,Inc                                    Type Code Symbol stamp                N/A Num                                      Authorization No                      N/A Rt. 3. Box 137G. Russellville, AR 72801                                        Expriation Date                        N/A Ahm
: 4. Identification of System MAIN STEAM (2 EBB-17)
SECTlH                                                      Addenda, NA
: 5. (a) Applicable Construction Code                                19 71      Edition. S-73                                                    code case (b) Applicable Edition of Section XI Utilized for Repairs of Replacements 19          86
: 6. Identification of Components Repairs or Replaced and Replacement Components ASME Code National                                      Repaired,                Stamped Name of                Name of                Manufacturer            Board        Other            Year        Replaced,                (yes Component            Manufacturer                Serial No.              No. Identification        Built      or Replacement              or No) 2" GATE                BORG-                    2465                N/A          2CV-1090-2          1974        REPAIRED                  YES VALVE                  WARNER
  \                                                                    ""
          \                                                              N/A N/A
: 7. Description ofWork REMOVED                          REWELDED BODY TO BONNET SEAL WELD
: 8. Tests Conducted              Hydrostatic l          l Pneumatic l  l Nominal Operating Pressure l          l Other l      l Pressure        NA        Psi      Test Temp NA                  F NOTE: Supplemental Sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2)informa-                      ;
tion in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
(12/82)                        This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 REPRINT 12/91 1
 
l l
!-                                                                                                                                                      Page 1 (Back) '
l                                                                                                                                                                        <
!                                                                                                                                                                        l l-                                                                                                                                                                      I l
1 FORM NIS-2 (Back)                                                                              ;
: 9. Remarks NA Applicable Manufacture's Data Reports to be anached l
?
i I
i CERTIFICATE OF COMPLIANCE -
We certify that the statements made in the report are correct and th                REPAIR                    confonns to the rules of the '
ASME Code, Section XL                                                                      Repair or Replacement l      Type Code Symbo1 Stamp                                                                    N/A' Certificate of Authorization No.                  _
N/A                  Expiration Date                                    N/A Signed                j ,-/ / ,                                              Date            52                                    ,19 %
Owner gir Owner's Desianee. TV 7 D.B. Lomax - Manager, Engineermg Programs CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State
    . or Province of          Arkansas                      and employed by                Factory Mutual Engineering Association                            of Norwood. MA                                                                            aw# haveins in this Ownefs Report during the period                  10/20/92                      to 7/7/rV '/I@pected the componentsdescrib to the best of my knowledge and belief, the Owner has performed examinations 'and tak'en corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed orimplied, concerning the examinations and corrective measures described in this Owners Report Furthermore, neither the Inspector norhis employer shall be liable in any manner for any personalinjury or property damage or a loss of any kind arising from or connected with this inspection.
kIC, [ M                                                      Conunissions                NB-9947, Ark.-Il33, "N" , "I" , "A"
      //                          inspector's Signature                                                    National Board, State Provira, and Endarnerneras v                              J.O. Elhott Date      8/.3                                  19 9 V
                                                                                .y
 
Page 1 (Front)
FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI
: 1. Owner AP&IlEntergy Operations,Inc                                            Date    01/04/94 Name Rt. 3 Box 137G, Russellville, AR 72801                                      Sheet        1                of        1 AMrses
: 2. Plant      Arkansas Nuclear One                                            Unit            Two Rt. 3, Box 137G, Russellville, AR 72801                                      JO# 00900999                                                      l A& hes                                                  Repsis Orgaruzaban P.O.No Job No etc.
: 3. Work Performed by AP&I1Entergy Operations,Inc                                Type Code Symbol Stamp                N/A N=                                      Authorization No                    N/A Rt. 3. Box 137G, Russellville, AR 72801                                    Expriation Date                      N/A                            j
                                        ^**=                                                                                                        l
: 4. Identification of System MAIN STEAM (2 EBB-1)
: 5. (a) Applicable Construction Code sm. m                      19 71      Edition, S-73              Addenda, 1574                    Code Case (b) Applicable Edition of Section XI Utilized for Repairs of Replacements 19      86
: 6. Identification of Components Repairs or Replaced and Replacement Components ASME Code National                                    Repaired,            Stamped    !
Name of              Name of              Manufacturer            Board      Other              Year        Replaced,            (yes      .
Component            Manufacturer              Serial No.              No. Identification          Built    or Replacement          or No) 8" GLOBE            CROSBY                  N58090-            N/A        2PSV-1055            1979        PART                  YES VALVE                                        00-0002                                                          REPLACEMENT 8" GLOBE            CROSBY                  N58090-            N/A        2PSV-1055            1979        PART                  YES VALVE                                        00-0010                                                          REPLACENENT N/A N/A N/A
: 7. Description ofWork REPLACED NOZZLE INSERT & DISC INSERTS IN VALVES
: 8. Tests Conducted            Hydrostatic l      l Pneumatic l    l Nominal Operating Pressure l        l Other l    l Pressure NA              Psi    TestTemp NA                    F                                    l NOTE: Supplemental Sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
l (12/82)                      This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017                    l l
REPRINT 12/91 l
l
 
l l                                                                                                                                                    Page 1 (Back) i FORM NIS-2 (Back)
: 9. Remarks NEW NOZZLE INSERT S/N N91560-36-0024 AND NEW DISC INSERT S/N N91562-00-0030 Applicable Manufacture's Data Reports to be attached FOR VALVE S/N N58090 00-0002 AND NEW DISC INSERT S/N N91562-36-0028 FOR VALVE S/N N58090-00-0010 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and th        REPLACEMENT conforms to the rules of the ASME Code, Section XI.                                                                    Repair or Replacement Type Code Symbol Stamp                                                                    N/A Certificate of Authorization No.                      N/A-                  Expiration Date                                  N/A Signed              I[
Owder or Owner's Desiance. Title /
                                                  /)                            Date          6-Z                                  ,19 'yh l            D.B. Lomax - Manager, Engineering Programs CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of          Arkansas-                ' and employed by              Factory Mutual Engineering Association                                of Norwood. MA                                                                            M_# haveinspected the componentsdescribed in this Owner's Report during the period                10/20/92                        to 7/7M dC "?'7 #//MM , and state that to the best of my knowledge and belief, the Owner has performed examinations'and talien corrective ' mea'sures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
Bysigning thiscertificate neitherthe Inspectornorhis employer makes any warranty, expressed orimplied,concerningthe examinations and corrective measures described in this Owner's Report.Furthermore, neither the Inspector norhis employer shallbe liableinany mamierforany personalinjury orproperty damageora lossofany kindarising fromorconnectedwiththis inspection.
9    O.    [ ./L M                                            Commissions                  NB-9947, Ark.-l133, "N" , "I" , "A"
(/                          Inspecies sipature J.O. Elliott
                                                                                                      . National Board, State, Pnmnce, and En&nements Date        S/.5                              19 9 V 1
I
 
l-f                                                                  .
Page 1 (Front) l                              FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS l
As Required By The Provisions Of The ASME Code Section XI                                                              i l~                                                                                                                                                            ;
1
  - 1. Owner AP&I/Entergy Operations, Inc                                            Date      03/27/94 Name                                                                                                              i Rt. 3, Box 137G, Russellville, AR 72801                                        Sheet        1                of        1 Ad*=                                                                                                                l
: 2. Plant      Arkansas Nuclear One                                                Unit-          Two Rt. 3, Box 137G, Russellville, AR 72801                                        JO# 00904161 Address                                                    Repaar Orgamzation F.O.No., Job No.,stc.                .
: 3. Work Performed by AP&IJEntergy Operations, Inc                                  Type code symbol Stamp                N/A Na=                                        Authorization No                      N/A                              l Rt. 3 Box 137G, Russellville, AR 72801                                        Expriation Date                      N/A                              l
                                          ^'**                                                                                                              j l 4. IdentificationofSystem HPSI(2CCB-70)                                                                                                                  -
, 5. (a) Applicable Construction Code psc                            19 69      Edition, SUPP 1 & 2 Addenda, NA                                code case l
(b) Applicable Edition of Section XI Utilized for Repairs of Replacements 19          86
: 6. Identification of Components Repdrs or Replaced and Replacement Components                                                                            ,
ASME Code National                                      Repaired,              Stampul i      Name of                Name of              Manufacturer              Board      Other            Year        Replaced,              (yes Compnent              Manufacturer            Serial No.                No. Identification        Built      or Replacement            or No)
COMPONENT              BECHTEL              NA                  N/A          2CCB-70-H6          E            REPAIRED                NA SUPPORT                                                                                            1972 N/A
                                                                        "'^
N                                                            "'^                                                                                  '
                \                                                      "'^
N  ,
: 7. Description ofWork MODIFIED SUPPORT
! 8. Tests Conducted              Hydrostatic ' l      l Pneumatic l    l Nominal Operating Pressure l            l Other l      l Pressure NA                Psi    TestTemp NA                      F NOTE: Supplemental Sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) informa-tion in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
(12/82)                      This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 REPRINT 12/91
 
                                                                                                                                                                                                          .1
)                                                                                                                                                                                                            I 4
j                                                                                                                                                                                          Page 1 (Back) 4                                                                                    ~
i FORM NIS-2 (Back) 1 1
;              9. Remarks NA                                                                                                                                                                                '
Applicable Manufacture's Data Reports to be anadied 1
J l
t e
i l
CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and th              REPAIR                    conforam to the rules of the l
ASME Code, Section XI.                                                                                    Repair or Replacement                                                    ,
i Type Code Symbol Stamp                                                                                      N/A Certificate of Authorization No.                                        N/A                    Expiration Date                                      N/A Signed                                          [
Owner or O/ncr's Demianos. Tale
                                                                                            /
Date              5-7.                            ,_ .19 94 D.B. Ianax - Manager, Engineenng Programs f
l                                                                                        CERTIFICATE OF INSERVICE INSPECTION                                                                                ,
,                      I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of                              Arkansas                  and employed by              Factory Mutual Engineering Associatio'n                                of      ;
Norwood. MA                                                                                        Agf haveinspected the componentsdescribed                              '
.                      in this Owner's Report during the period                                  10/20/92                        to 7/7/95/ Y//idf v//M9v ,and statethat to the best of my knowledge and belief, the Owner has performed examinations 'and taken corrective ' measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
;                                  By signing this certificate neither the Inspector nor his employer makes any warranty, expressed orimplied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his' employer shall be liable in any manner for any personalinjury or property damage or a loss of any kind arising from or connected with this                                                    i
!                      inspection.                                                                                                                                                                          !
i 9 . C.                      [M                                              Commissions                  NB-9947 Ark.-l 133 "N" , "I" , "A"                                  4
(/
Inspectes sipature                                                      National Board, State, Province, and Endormerneras J.O. Elliott Date                      5/3                                199 Y l
4
 
Page 1 (Front) ]
FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI
: 1. Owner AP&I1Entergy Operations,Inc                                            Date      04/20/94 Name Rt. 3, Box 137G, Russellville, AR 72801                                      Sheet -      1                  of                      1 Ahas
: 2. Plant        Arkansas Nuclear One                                            Unit            Two Rt. 3, Box 137G, Russellville, AR 72801                                      J0# 00905763 Address                                                    Repair Organization P.O.No., Job No stc.
: 3. Work Performed by AP&I1Entergy Operations, Inc                                Type Code Symbol stamp                    N/A-N=                                      Authorization No                        N/A Rt. 3, Box 137G, Russellville, AR 72801                                      Expriation Date                          N/A Ahas
: 4. Identification of System CVCS (2HCB-65)
: 5. (a) Applicable Construction Code        SECT. n!
                                                                }9 7}      Edjtion, W-72                  Addenda, N/A                              Code Case (b) Applicable Edition of Section XI Utilized for Repairs of Replacements 19        86                                                                    j
: 6. Identification of Components Repairs or Replaced and Replacement Components ASME        I Code National                                        Repaired,                      Stamped      !
Name of              Name of              Manufacturer            Board          Other            Year          Replaced,                      (yes Component            Manufacturer              Serial No.              No. Identification          Built      or Replacement                  or No)      t 2" CHECK              ROCKWELL              KA-609              N/A        2CVC-78                1974          REPAIRED                        YES VALVE N/A N/A                                                                                          ]
N/A N/A
: 7. Description ofWork MACHINED VALVE DISC ON BOTH SIDES
: 8. Tests Conducted            Hydrostatic l        l Pneumatic l  l Nominal Operating Pressure lXl Other        l Pressure 135            Psi    TestTemp AMB                        F NOTE: Supplemental Sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
(12/82)                      This Form (E00030) may be obtained frora the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 REPRINT 12/91
 
J Page1(Back) 4 4
FORM NIS 2 (Back) 1-
: 9. Remarks MACHINED .0025 " FROM EACH SIDE OF DISC S/N 483550 Apphcable Manuf acture's Data Reports to be anached i
4 4
4
$                                                                                                                                                                      l i                                                                                                                                                                    !
;.                                                                                                                                                                    l l                                                              CERTIFICATE OF COMPLIANCE j                We cenify that the statements made in the report are correct and this                        REPAIR            confornu to the mies of the ASME Code, Section XL                                                                          Repair or Replacement Type Code Symbol Stamp                                                                            N/A Cenificate of Authorization No.                  _
N/A                  Expiration Date                                N/A Signed                  [/        .
Date            bp J                                ,19q4
            , ownpf or owners Desinnee. Tibe '                                                    ,
;              D.B. Lomax - Manager, Engineering Programs l                                                      CERTIFICATE OF INSERVICE INSPECTION
!  I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of            Arkansas                      and employed by                Factory Mutual Engineering Association                            of Norwood, MA                                                                                AA# haveinspected the componentsdescribed
;  in this Owner's Report during the period                      10/20/92                        to7/r/N88/M F/#F/9</ ,and statethat to the best of my knowledge and belief, the Owner has performed examinations and 'taken' corrective' measures described in this
{  Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed orimplied, concerning the examinations and corrective measures described in this Owner's Report , Furthermore, neither the Inspector nor his employer 1
shall be liable in any manner for any personalinjury or property damage ora loss of any kind arising from or connected with this                                  ,
4 inspection.                                                                                                                                                      1 i
l i
9, O.            [M;I9                                              Commissions                NB-9947. Arli.-l133, "N" , "I" , "A" g                            Inspector's Signature                                                        National Board. State, Province, and era .. e J.O. Elliott 1
l                                                                                                                                                                    i
.;      Date W 3                                            19 'l '/                                                                                                  I
:            e7                                                                                                                                                      !
i
 
i Page 1 (Front) l                          FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS                                                                            I i                                    As Required By The Provisions Of The ASME Code Section XI                                                              l l                                                                                                                                                            l l
: 1. Owner AP&I1Entergy Operations, Inc                                          ,
Date      04/20/94 Name Rt. 3, Box 137G, Russellville, AR 72801                                          Sheet        1              of          1                          l Ahn
: 2. Plant      Arkansas Nuclear One                                                  Unit            Two Rt. 3, Box 137G, Russellville, AR 72801                                          JO# 00905763 Address                                                      Repair Orgaruzation P.O.No Js No etc.
: 3. Work Performed by AP&I1Entergy Operations, Inc                                    Type Code Symbol Stamp                N/A N=                                          Authorization No                      N/A Rt. 3. Box 137G, Russellville, AR 72801                                          Expriation Date                      N/A Am.
: 4. Identification of System CVCS (2HCB-65) r
: 5. (a) Applicable Construction Code      su m                19 83          Edition, S-84              Addenda, N/A                    Code Case      ,
(b) Applicable Edition of Section XI Uti!ized for Repairs of Replacements 19            86
: 6. Identification of Components Repairs or Replaced and Replacement Components ASME Code National                                        Repaired,          Stamped Name cf              Name of                Manufacturer              Board        Other            Year          Replaced,          (yes Compoiant            Manufacturer                Serial No.                  No. Identification        Built    or Replacement          or No) 2" CHECK            ROCKWELL                  KA-609              N/A            2CVC-78            1974        REPLACED                YES VALVE 2" CHECK            EDWARDS                  95AFF              N/A            2CVC-78            1992        REPLACEMENT YES VALVE                                                                                                                                                    I N/A N/A N/A
: 7. Description of Work CUT-OUT AND REPLACED VALVE
: 8. Tests Conducted            Hydrostatic J
[X Pneumatic l        l Nominal Operating Pressure l Psi      Test Temp AMB l
F Other l    l Pressure      189 NOTE: Supplemental Sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is                        ,
recorded at the top of this form.                                                                                                                    l (12/32)                      This Form (E00030) may be obtained from the Order Pm , ASME,345 E. 47th St., New York, N.Y.10017 REPRINT 12/91
 
_.                              -                          .        .      .          ._ ~. ,_ _                                                .        _ ___
i                                                                                                                                                          Page 1 (Back)    '
J J
}                                                                      FORM NIS-2 (Back)
L 4
: 9. Remarks NPV-1 MANUFACTURERS DATA REPORT FOR REPLACEMENT VALVE ATTACHED-
,                                                                    Apphcable Manufacture's Data Reports to be attached 1
4 1
a i                                                                                                                                                                            .
~
CERTIFICATE OF COMPLIANCE g                We certify that the statements made in the report are correct and this              REPLACEMENT conforms to the rules of the
;    ASME Code, Section XI.-                                                                    Repair or Replacement l
Type Code Symbol Stamp                                                                      N/A
{
,  Certificate of Authorization No.                  _
N/A                  Expiration Date                                      N/A Signed                    [f
                                                    ./
[                            Date V
g 3                              ,19 8h  .
Owner orp Desinnee. Tnle
          -#  D.B. Lomax - Manager. Engineering Programs CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State                                        l i    or Province of          Arkansas                      and employed by            Factory Mutual Engineering Association                                  of Norwood, MA                                                                              AA/ haveinspected the componentsdescribed j    in this Owners Report during the period                    10/20/92                      to7h/rV UMff' '//f#9v ,and statethat to the best of my knowledge and belief, the Owner has performed examinations 'and then dorrective ' measures desenkd in this
!    Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty,- expressed or implied, concerning the j    examinations and corrective measures described in this Owner's Report.Furthermore, neither the Inspector norhis employer .
shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this                                      ;
I inspection.
!                                                                                                                                                                          l O.C.Slb                            '
Commissions                        NB-9947. Ark.-ll33 "N" , "I" , "A" I  /7                            Inspector's Signature                                                        National Board, State. Province, and Endorsements 1  (/                              J.O. Elliott 1
Date L3                                          19 Cf</
!-            g 4
l
 
atC V e - 72 Sfg 95'RFF
    ~
FORM NPV 1 N CERT 1FICATE HOLDERS
* DATA REPORT FOR NUCLEAR PUM8 OR VALVES
* As Required by the Provisions of the ASME Code, Sectior. Ill. Div.1
: 1. Manufactured by          Ib                - d d e. s I.u        /900 d. % % M.                        '
b l*e.d_  "'
A)C 2_Pble b(tvame          and AadressI-_
at . Ow aY.*u .
of% Certif PJ 6cate
                                                                                          *1      Holder;hr LT76 b c, p//.a*[r_ 4 /.
: 2. Manufactured for th      e enb Aooress of F
: 3. Location of installation                  be A/                noser
                                                                          ~ A+ of Owner:bffarMus*Ms 4M.
tNo e eno Acoress
: 4. Pump or Valve                      \ 'ldo                            Nominal inlet Site                    2-            Outiet Site              2 (anch)                                    Onch) lal Model No., (b) N Cettificate Holder's (c) Canadian Senes No.                    Serial              Registration          (d) Drawing                              (f) Nat'l.      (g) Year or Type                        No.                    No.                    No.              (e) Class          Bd. No.            Built g,,          Fx~CWF1thrt 93AFF '
s/A          M 2 -ts4.19-of                  I              J/A-            iser g1,                  &                    'f MFF '                    b                    4                      4                &                  $
G3i            L1c.1Nb"M WI                  %AFF                    A            D*f t-L9135 -ol                I                xlA              199 0 (a)
(5)
(6)
(7)
(s)                                                                                                                                                          .
(9)
(10;                                                                                                                                                      _.
: 5.                          "15                                                                                                                                  . l
                                                        .n.t    - of ~. or                  . .eu,orr,    ,t wee or,.e,                                                        .
S.o.E3L - 25939                                  l
: 6. Design Conditions                  2MO                p.;                Boo            *F or Valve Pressure Class                          /UO          " (1 )
(Preemaal                      (Tomooreture)                                                                                        i
: 7. Cold Working Pressu're                    Mb'        psi et 100*F.
: 8. Pressure Retaining Pieces                                                                                .
                                                                                                            . .a..e.
                                                                                                                .                    .                          +
f . 4 , Manufacturer
                * ',. ' Mark No.                            Material Spec. No.                                                                    Remarks                    )
(a) Castings                                                                                                                                                      !
                        &                      %)G, llMSL Gv. tJ e
k n O)2a) O l'                .r hp/c
                                      - -                .+ . ..                      ..                              .
l l                    .                  . .    .
t                                                                                                .
I i
.                                                l (b) Forgings TMA/A                                                                      'Th%*h fen e-                            6e dw 001                  \ T% A 1
rtrLIi L &&c. F: P'1,i
                                                                            .  ~
                                                                                    '                .Z.T & id                                L A.
: 1. M u -saI                  eA ws c rp                _.
Ml <;;L (                              ' & L.
                        / '5'1 BC                    M 4 7 f 7"'t/(.                              (* .J / , n af                          d.a.e/
                  ..                              l 1
I til For manually operated valves osv.
* Supplemental sheets in form o'iets, sketches or drawings may be used provided (1) size is 8-112" x it", (2) information in items 1. 2 and 5 on this Data hoort is ir t'uded on each sheet. and (3) each sheet is numbered and number of sheets is recorded at top of this forrrt (10/77)                              Thnwm (E00037) mey be obtained from the Order Darst., A3ME,345 E. 47th St., New York, N.Y.10017
 
s                          .      -
m P. t J 1-rom Nev.1 teacu                                          s SA.* 9W-TM Material Spec. No.                      Manufacturer                    Remarks Mark No l
(c) Boiting                                                                  l l
l
                                    }
l l
l                                                        l l                                                                                                      I l                                      I l
(o) Otner Paris              l l                                      1
!                                      1 l
t l
l l
: 9. Hydrwtstic test    d/**      osi . Disk Differential test pressure    ** d- psi .
}
                                          .            CERT 1FICATE OF COMPUANCE We certsfy tnat the statements made in this r' sport are correct and that this pump, or valve, conforms to the rules of construction of the ASME Code for Nuclear Power Plant Corhponents. Section ut, Div. L. Edition 8U          ,
NwM%                        , Code Case No.                M/d                ate      /O      /M    /    h Addenda 5;gned          Il        d        a1 Jess .1*m e. .                      wy                "
A              1              _
(N C#tiMcate Heleer) j f A/ /M              to use the
* AI "        symbol expires MINI N .
Our ASME Certificate of Authorization No.                                                (M)                                (Detop l
l
                                              .            CERTIFICATION OF DESIGN Design information on file at                &d db I = -                        N.A e_1J. w/ft u ses Stress analysis report (Class 1 only) on nie at            A~/ d J Val /se. A .#. M /- -d -de.
Design specifications certified by (1)          N_dh ske/ A. Ondwed PE State        AE                    Reg.No.      6/ '5 N Stress analysis cemfied by (1)              Id. AIo-e PE State          M O"              Reg. No. W M */
(1) Signature not recuired. List name only.                            ,
CERTIFICATE OF SHOP INSPECTION f
l 1, the undersigned, holding a valid c mmission issued by the National Board of Soiler and Pressure Vessel inspectors Me          bN                          and employed by N
* Ib*
and the State or Provi ce of of                        ;
have inspected the pump, or valve. described in this Data Report on
                                / #-E S 191, a nd state that to the best of my knowledge and belief, the N Certificate Holder has con-structed this pump, or valve. in accordarice with the ASME Code, Section Ill.
                                                                                                                        ~
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the equipment described in this Data Report. Furthermore, neither the inspector nor his employer shalt be liable in any mann          ny personal ' jury or property damage or a loss of any kind arising from or connected with this inspection, f      Date        ~          /        /O'M 19 9 L.
{**                                                        Commissions                /O (Nert ed., State. Prov. and No.)
l
                            * (port l
 
l l
Page 1 (Front)  l FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS                                                                    I As Required By The Provisions Of The ASME Code Section XI
: 1. Owner AP&IJEntergy Operations,Inc                                            Date      03/26/94 Name Rt. 3, Box 137G, Russellville, AR 72801                                    Sheet        1              of          1                          ,
Am
: 2. Plant        Arkansas Nuclear One                                          Unit          Two Rt. 3, Box 137G, Russellville, AR 72801                                      JO# 00907954 Address                                                  Repaar Orgamzation P.O.No. Job No.,etc.
: 3. Work Performed by AP&I/Entergy Operations,Inc                                Type Code symbol stamp              N/A N=                                    Authorization No                    N/A Rt. 3. Box 137G, Russellville, AR 72801                                    Expriation Date                      N/A Addre.s
: 4. Identification of System LPSI (2GCB-5 )
: 5. (a) Applicable Construction Code        sm.m              19 69      Edition, SUPP.1 & 2 Addenda, NA                              Code Case (b) Applicable Edition of Section XI Utilized for Repairs of Replacements 19        86
: 6. Identification of Components Repairs or Replaced and Replacement Components ASME Code National                                  Repaired,              Stamped Name of                Name of              Manufacturer          Board        Other          Year        Replaced,              (yes Component              Manufacturer            Serial No.              No. Identification        Built    or Replacement            or No) l COMPONENT              BECHTEL                NA                N/A        2GCB-5-H14 -      E          REPAIRED                  NO SUPPORT                                                                                          1972 N/A
                                                                        "'^
N                                                          N/A l
N/A
: 7. Description ofWork MODIFIED SUPPORT
: 8. Tests Conducted            Hydrostatic l        l Pneumatic l    l Nominal Operating Pressure l        l Other l      l Pressure NA            Psi    Test Temp NA'                F NOTE: Supplemental Sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) informa-tion in items I through 6 on this repon is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
(12/82)                      This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 REPRINT 12/91
 
};
l                                                                                                                                                                                    Page 1 (Back) 4                                                                                                                                                                                                        i 4
i 1
: j.                                                                        FORM NIS-2 (Back) _
i
! ' ' 9. Remarks NA Applicable Manufactures Data Reports to be attached                                                                            I 1
[                                                                                                                                                                                                    >
i i
3 i
1 1
}                                                            CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and th                REPAIR                                              confonns to the' rules of the
]-
j      ASkE Code, Section XI.                                                                    Repair or Replacement i
i 4      Type Code Symbol Stamp                                                                      N/A j      Certificate of Authorization No.                      N/A                    Expiration Date                                                            N/A Signed                                  .
d                              Date            S-Z                                                          ,19 %                          '
l                  Owner onCwrds Desianee. Title D.B. Lomax - Manager, Engineering Programs 1'                                                                                                                                                                                                    >
1 i                                                        CERTIFICATE OF INSERVICE INSPECTION
,      I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State                                                            !
or Province of            Arkansas                  and employed by                  Factory Mutual Engineering Association                                                        of Norwood. MA                                                                              4 War haveinspected the componentsdesenhd
)      in this Owners Report during the period                  10/20/92                        to 7/## '/,NU M/Mf( , and state that
                                                                                                                    ~                                                                                ;
3      to the best of my knowledge and belief, the Owner has performed examinations and taken co'rrective measures described in this                                                                  '
i      Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed orimplied, concerning the                                                              !
examinations and corrective measures described in this Owner's Report.Furthermore, neither the Inspector norhis employer j      shall be liable in any manner for any personalinjury or property damage or a loss of any kind arising from or connected with this inspection.
{
1 I
O.      [/k                                                Commissions                  NB-9947, Ark.-l133, "N" , "1" , "A" inspector's Sipature                                                    National Board, State. Province, and Endorsemanas                                        -
1                                      J.O. Elltott Date          S/3                              19 94 e                                                                                                                                                                                                      .
t
 
l l
Page 1 (Front)
{                              FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI 1,
4
: 1. Owner AP&I/Entergy Operations, Inc                                            Date      04/06/94 Name Rt. 3, Box 137G, Russellville, AR 72801                                      Sheet        1              of            I
;                                          ^*'*
1  2. Plant        Arkansas Nuclear One                                              Unit          Two l-      Rt. 3, Box 137G, Russellville, AR 72801                                        JO# 00907970 Address                                                    Repaw Orgaruzahon P.O.No Job No stc.
4
: 3. Work Performed by AP&I/Entergy Operations,Inc                                  Type Code symbol stamp              N/A I                                          Name                                      Authorization No                    N/A
.      Rt. 3. Box 137G, RusselMlle, AR 72801                                        Expriation Date                      N/A Ahas
! 4. Identification of system CONTAINMENT SPRAY (2HCB-3 )
J j  5. (a) Applicable Construction Code Alsc                        19 69    Edition, SUPP 1 & 2 Addenda, NA                            Code case j        (b) Applicable Edition of Section XI Utilized for Repairs of Replacements 19        86 i
: 6. Identification of Components Repairs or Replaced and Replacement Components ASME Code National                                  Repaired,            Stamped Name of                Name of            Manufacturer            Board        Other            Year      Replaced. -            (yes j    Component              Manufacturer          Serial No.                No. Identification        Built    or Replacement          or No)
,    COMPONENT              BECHTEL              NA                  N/A          2HCB-3-H179        E          REPAIRED                NO i    SUPPORT                                                                                            1972
                                                                        "'^
:        N                                                            "'^
N                                                      "'^
N
: 7. Description ofWork MODIFIED SUPPORT i
1
: 8. Tests Conducted            Hydrostatic l      l Pneumatic l    l Nominal Operating Pressure l        l Other ] Pressure          NA            Psi      Test Temp NA -              F NOTE: Supplemental Sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) informa-
,        tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.                                                                                                            '
i i' (12/82)                        This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 I
REPRINT 12/91 1
4 5-
 
xe-.s    u      -.                  -        s, s        . . . . .      .-    -r          -    ,,                            s. a.. 2        ~  m-.s -
5 l
Page 1 (Back) i
]
1
:                                                                          . FORM NIS-2 (Back)
: 9. Remarks NA Applicable Manuracurn Data Repans to tw anacbed i
a i
4 i
l t
k I                                                            CERTIFICATE OF COMPLIANCE j                    We certify that the statements made in the report are correct and this                REPAIR            confonns to the rules of the.
4 ASME Code, Sectica XI.                                                                      Repair or Replacement 1
j    Type Code Symbol Stamp                                                                      N/A 1
Certificate of Authorization No.                          N/A                  Expiration Date                                  N/A
{                                                                                                                                                                            ;
Signed                    h[
owne/arown <sDesianes Tiue r
                                                                                      .Date          $ . 2, ~                                ,19 %
}
j              D.B. Lomax - Manager, Engmeenng Programs
;                                                    CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of              Arkansas Norwood. MA and employed by                Factory Mutual Engineering Association                            . of
                                                                                                    .'?# have i
!    in this Owners Report during the period                      10/20/92                      to7/p/rv #1%ged the      , , -
componentsh;bs:
V//v/FF            , and statetht i    to the best of my knowledge and belief, the Owner has performed examinatioris 'and tallen corrective ' measures described in this
. Owner's leport in accordance with the requirements of the ASME Code, Section XI.
i          By signin,', this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the l    examinations and corrective measures described in this Owners Report.Furthermore, neither the Inspector nor his employer
;    shall be liable o any manner for any personalinjury or property damage or a loss of any kind arising from or connected with this
;    inspection.
k . C. b/A                                                          Commissions              NB-9947, Ark.-1133, "N" , "1" , "A" g                            inspectors Sipahre J.O. Elhott National Board, State. Province, and Emdarsernents 4        Date        8/3                                19 9 a/
 
                -    =        .        . .        -      -  -                .        -      .. ...                  ---        .__            _          _
Page 1 (Front)
FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI
: 1. Owner AP&I1Entergy Operations,Inc                                                  Date        04/22/94 Names Rt. 3, Box 137C, Russellville, AR 72801                                          Sheet              1-              of          I uem.
: 2. Plant ~ Arkansas Nuclear One                                                        Unit                  Two Rt. 3, Box 137G, Russellville, AR 72801                                          JO# 00907972 Addrums                                                ..
Repaar Organzataan P.O.No., Job No.,sec.
: 3. Work Performed by AP&IJEntergy Operations, Inc-                                    Type Code Symbol Stamp                      N/A Naa=                                          Authorization No                            N/A Rt. 3. Box 137G, Russellville, AR 72801                                          Expriation Date                              N/A us
: 4. Identificatica of System M.S. ( 2 EBB-1 )
: 5. (a) Applicabic Construction Code          sum                  19 71      Edition, . S-73                    Addenda, 1574                      Code Case (b) Applicable Edition of Section XI Utilized for Repairs of Replacements 19                86 6.' Identification of Components Repairs or Replaced and Replacement Components ASME Code National                                              Repaired,            Stamped Name of              Name of                  Manufacturer            Board        Other                    Year          Replaced,                (yes Component              Maanrm-turer                Serial No.                No. Identification '            Built    or Replacement              or No) 8' GLOBE              CROSBY                    N58090-            N/A            2PSV-1006                  1979        PARTS                    YES VALVE                                            00-0013                                                                    REPLACEMENT
                                                                      *^
\                                                                      "'^
N                                                              N/A l
N/A                                                                                          l
: 7. Description ofWork _ REPLACED NOZZLE AND DISC INSERTS
: 8. Tests Conducted              Hydrostatic l          l Pneumatic l    l Nominal Operating Pressure l                  l                                            1 Other l        l Pressure    N/A          Psi      TestTemp N/A                          F 1
NOTE: Supplemental Sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
i (12/82)                      ' This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 REPRINT 12/91
 
4 i
j                                                                                                                                                          Page 1 (Back) k l
e f
,                                                                            FORM NIS-2 (Back) i'
[      9. Remark.s REPLACED NOZZLE INSERT AND DISC INSERT                                                                                                                    j
;                                                                        Apphcable Manufacsure's Data Reports to be enached j            NEW NO77IF. INSERT S/N N91560-35-0017                                                                                                                          4 I
4 i            NEW DISC INSERT S/N N91562-37-0032                                                                                                                            l l
i i
l                                                                                                                                                                          -)
!                                                                                                                                                                            I a                                                                                                                                                                            1 CERTIFICATE OF COMPLIANCE                                                  .
                                                                                                                                                  .      .                  j We certify that the statements made in the report are correct and this          REPLACEMENT confonns to the mies of the                              i ASME Code, Section XI.                                                                    Repair or Replacement                                                    l l                                                                                                                                                                            l Type Code Symbol Stamp                                                                    N/A                                                                      ;
j_      Cenificate of Authonzation No.                        N/A                    Expiration Date                                      N/A                              l Signed            _[          [          , . E>                              Date          hup O/                                  ,19    %-                    l 1                    ownn/r ownes twiime.Tak /
D.B. Lomax - Manager, Engmeermg Programs p
l_                                                      CERTIFICATE OF INSERVICE INSPECTION
!        1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State 1        or Province of            Arkansas                    and employed by              Factory Mutual Engineering Association                                  of Norwood, MA                                                                                                            ed the components described            l
!        in this Owner's Report during the period                  10/20/92                          M/ have p?# F/df9/W ,and statethat to 7/7/r/ " rite                                                          l i        to the best of my knowledge and belief, the Owner has performed examinations'and then f:orrective me'asures ds#ued in this                                        l j        Owner's Report in accordance with the requirements of the ASME Code, Section XI.                                                                                  j
;            By signing this certificate neither the Inspector nor his employer makes any warranty, expressed orimplied, concermag the
: j.        examinations and corrective measures described in this Owner's Report.Furthermore, neither the Inspector nor his employer
!        shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this 4
inspection.
i
.i                                    e b.C, [_f4 M                                      i Ommissions                NB-9947, Ark.-113 3, "N" , "I" , "A"                              1
}      ' /7                          Inspector's Sipature                                                    National Board, State, Province, and Endorsernsuls            j
(/                              10. Elliott                                                                                                                        !
i
'                                                                                                                                                                            I Date -Q M J .7                                19 W                                                                                                              )
j 6
I O_
                  ,                                              .-                              -                        . _ _ _ _        ______________.____._l
 
1 i
.i j                                                                                                                                                    Page 1 (Front) i                            FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI
: 1. Owner AP&IJEntergy Operations,Inc                                                      Date      04/22/94 Name Rt. 3, Box 137G, Russellville, AR 72801                                                Sheet        1'                of            I us
: 2. Plant        Arkansas Nuclear One                                                      Unit.            Two Rt. 3, Box 137G, Russellville, AR 72801                                                JO# 00907972 Mdrums                                                          Repaa Organizahon P.O.No Job Na,asc.
: 3. Werk Performed by AP&l/Entergy Operations, Inc .                                        Type Code Symbol Stamp                    N/A N=                                          Authorization No                          N/A-Rt. 3. Box 137G, Russellville, AR 72801                                                Expriation Date                            N/A u&a.
: 4. Identification of System M.S. (2 EBB-1 )
: 5. (a) Applicable Construction Code              smrm                19 71          Edition, S-73                  Addenda, 1574                    Code Case    j (b) Applicable Edition of Section XI Utilized for Repairs of Replacements 19                  86
: 6. Identification of Components Repairs or Replaced and Replacement Components i
ASME      I Code National                                        Repaired,            Stamped Name of              Name of                      Manufacturer              Board      . Other              Year        Replaced,              (yes Component            Manufacturer                    Serial No.                  No. Identification            Built    or Replacement          or No) i 8" GLOBE              CROSBY                        N58090-            N/A            2PSV-1006              1979      REPLACED                YES        >
VALVE                                              00-0010 8" GLOBE              CROSBY                        N58090-            N/A            2PSV-1006              1979      . REPLACEMENT YES VALVE                                                00-0013 N/A N/A I
: 7. Description ofWork REMOVED EXISTING VALVE AND REPLACED WITH SPARE VALVE
: 8. Tests Conducted                  Hydrostatic l          l Pneumatic l    l Nominal Operating Pressure lXl Other l      l Pressure 1000-              Psi    Test Temp 545                    F NOTE: Supplemental Sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) informa-tion in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
(12/82).                          This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 REPRINT 12/91 l
 
i Page 1 (Back) e i
!                                                                    FORM NIS-2 (Back) i
: 9. Remarks THESE RELIEF VALVES ARE REPLACED EVERY REFUELING OUTAGE .
j                                                                  Appi.e.bi. u-u*-o n.= a.pon a b. .-~                                                              l l        NPV-1 MANUFACTURERS DATA REPORT PREVIOUSLY PROVIDED                                                                                                        .
!                                                                                                                                                                  s
}
i                                                                                                                                                                    i h                                                                                                                                                                    :
i                                                                                                                                                                    !
I
.i                                                                                                                                                                  ,
CERTIFICATE OF COMPLIANCE                                                                                  l j                We certify that the statements made in the report are correct and this        REPLACEMENT ' conforms to the rules of the
;    ASME Code, Section XI.                                                                Repair or Replacement Type Code Symbol Stamp                                                                  N/A l    Certificate of Authorhation No.                      N/A-                  Expiration Date                                N/A Signed            .]          i owner hs Designerritne (
                                                ,f                              Date          ,,,, g ' 3)/
                                                                                                                                          ,19 N l                                                                                              '
j              D.B. Lomax - Manager, Emgineenng Programs I
!                                                CERTIFICATE OF INSERVICE INSPECTION                                                                                )
!'  I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State
!    or Province of          Arkansas                  and employed by                Factory Mutual Engineering Association - ,                        of i        Norwood. MA                                                                          mo/1/ haveinspected the componentsdescribed in this Owner's Report during the period                10/20/92                      to 7NN UN/n' 9/,W/94/ , and state that
    ~ to the best of my knowledge and belief, the Owner has performed examinations and taken corrective' medsures described in this Ouer's Report in accordance with the requirements of the ASME Code, Section XI.
I        By signing this certificate neither the Inspector nor his employer makes any warranty, expressed orimplied, concerning the
,    enminations and corrective measures described in this Own,:r's Report .Furthermore, neither the Inspector norhis employer
. shallbe liableinany mannerforany personalinjury orproperty damageora lossof any kindarising fromorconnectedwiththis I  inspection.
4 4
~
    //
: 9. O .[h                  Inspeews Sipuhre Commissions                NB-9947, Arit.-Il33, "N" "I" , "A" '
National Board, Stau, Pnmnoe, and Endorserness
;  f/                              - J.O. Elliott i
-      Date LM a ;t                                19 7 $/
!            6 i
 
Page 1 (Front)
FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI
: 1. Owner AP&L/Entergy Operations, Inc                                                    Date    04/22/94 Name Rt. 3, Box 137G, Russellville, AR 72801                                            Sheet        1                of          1 Addr
: 2. Plant          Arkansas Nuclear One                                                  Unit          Two Rt. 3, Box 137G, Russellville, AR 72801                                              JO# 00907980 Address                                                        Rapaar Ort =*= P.O.No., Job No.,sec.
: 3. 'VorkPerformedby AP&IJEntergy Operations,Inc                                        Type code symbol Stamp                  N/A N=                                            Authorization No                      N/A 3 3. Box 137G, Russellville, AR 72801                                                Expriation Date                        N/A Address
' 4. Identification of system M.S. ( 2 EBB-2 )
: 5. (a) Applicable Constmetion Code smrn!                        19 71      Edition, S-73                      Addenda, 1514                  Code Case (b) Applicable Edition of Section XI Utilized for Repairs of Replacements 19              86
: 6. Identificatien of Components Repairs or Replaced and Replacement Components ASME Code National                                          Repaired,          Stamped Name of              Name of                Manufacturer          Board              Other            Year        Replaced,          (yes Component            Manufacturer              Serial No.              No.        Identification        Built      or Replacement        or No) 8" GLOBE              CROSBY                  N58090            N/A              2PSV-1052          1979          PARTS                YES        l VALVE                                          00-0003                                                                REPLACEMENT N/A x                                                            Nm N/A N/A
  -7. Description ofWork REPLACED NOZZLE AND DISC INSERT
: 8. Tests Conducted            Hydrostatic . l      l Pneumatic l  l Nominal Operating Pressure l                l Other l      l Pressure    N/A        Psi      TestTemp N/A                        F NOTE: Supplemental Sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
!(12/82)                        This Form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N.Y.10017 REPRINT 12/91-u_______ _ _ _ ____ __ _                                                          _ _ _ . .
 
3 i                                                                                                                                                      Page 1 (Back)
)
i j                                                                          FORM NIS-2 (Back)
!    9. Remarks REPLACED NO771R INSERT AND DISC INSERT Applicable Manufemure) Data Reports to be ana&nd
:          NEW NOZZLE INSERT S/N N91560-36-0025 i
j'        . NEW DISC INSERT S/N N91562-37-0034 i
i I
2 a
.                                                              CERTIFICATE OF COMPLIANCE -
;                    We cc:try that the statements made in the icport are correct and this            REPLACEMENT conforms to the rules of the .
j      ASME Code, Section XI.                                                                      Repair or Replacement b
4 i
Type Code Symbol Stamp                                                                      N/A Certificate of Authonzation No.          ,                N/A                    Expiration Date                                N/A Signed                                        J                                  Date                p Ql                              ,19 M
                    -- De -. me r D.B. Lomax - Manager, Engmeenng Programs v
CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of            Arkansas                      and employed by              Factory Mutual Engineering Association                            of Norwood. MA                                                                              A S / y#              i        the componentsdescribed in this Owner's Report during the period                    10/20/92                      to7hh4' 4 ##.'p' #f VIW/99, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken cdtrective incasures described in this
,      Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warrar.ty, expressed or implied, concerning the examinations and corrective measures described inthis Owner's Report,Furthermore, neither the Inspector norhis employer shall be liable in any manner for any personalinjury or property damage or a loss of any kind arising from or connected with this inspection.
9e C.          [                                                    Commissions                NB-9947, Ark.-1133, "N" , "l* , "A"
                                                                                                                                                ~
National Board, State Provm, and Emensements l
inspedds Signature
: 10. Elhott Date QiM 2 .2                                      19 *l '/
9 l
~ _ _ _ _ _ -                                                                                            . -                          -
 
Page 1 (Fr:nt)
FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS
$                                            As Required By The Provisions Of The ASME Code Section XI                                                                      l 1
* I
: 1. Owner AP&L/Entergy Operations,Inc                                                            Date      04/22/94                                                    l j                                                    Name j        Rt. 3, Box 137G, Russellville, AR 72801                                                      Sheet        1                of        1 l                                                  Ad*=
l  2. Plant          Arkansas Nuclear One                                                          Unit            Two Rt. 3, Box 137G, Russellville, AR 72801                                                      JO# 00907980 l                                                Addrums                                                              Repaar Orgamzauan P.O.No Job No.,sec.
4  3. Work Performed by AP&I1Entergy Operations, Inc                                                Type Code Symbol Stamp                N/A
!                                                  Name                                              Authorization No                      N/A
;        Rt. 3. Box 137G, Russellville, AR 72801                                                      Expriation Date                        N/A i                                                  44
: 4. Identification of System M.S. (2 EBB-2 )                                                                                                                              .
l
!    5. (a) Applicable Construction Code              SECTIU                    19 71 - Edition, S.73                        Addenda, 1574                    Code Case (b) Applicable Edition of Section XI Utilized for Repairs of Replacements 19                      86
{
l  6. Identification of Components Repairs or Replaced and Replacement Components
)
i
!                                                                                                                                                              ASME j                                                                                                                                                                Code 1                                                                                        National                                      Repaired,              Stamped        !
j      ' Name of                      Name of                Manufacturer                Board        Other              Year      Replaced,              (yes        !
;      Component                  Manufacturer                      Serial No.                No. Identification          Built    or Replacement            or No)      l 4                                                                                                                                                                            1 l      8' GLOBE                    CROSBY                    N58090-                N/A            2PSV-1052            1979      REPLACED                YES i      VALVE                                                  00-0003 8' GLOBE                  CROSBY                      N58090-                N/A            2PSV-1052            1979      REPLACEMENT YES VALVE                                                  00-0005
                                                                                      "'^
      \                                                                                N/A                                                                                  I l
N/A                            e j  7. Description ofWork REMOVED EXISTING VALVE AND REPLACED WITH SPARE VALVE
: 8. Tests Conducted                  Hydrostatic l              l Pneumatic l      l Nominal Operating Pressure lXl Other l    l Pressure 1000                    Psi    Test Temp 545                    F NOTE: Supplemental Sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is j            recorded at the top of this form.
(12/82)                              This Form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N.Y,10017 REPRINT 12/91 e
i
 
                                                                  . ~ . _                ~      ,,        .              ..-.._-.~...-_....wa
                                                                                                                                  .                        ._a      ,.a.-._. =,
Page1(Back)
FORM NIS-2 (Back)
: 9. . Remarks THESE RELIEF VALVES ARE REPLACED EVERY REFUELING OUTAGE
                                                                              . 4,phobi. u.-r.a o tw. a.p== = 6. .n=*.d NPV-1 MANUFACTURERS DATA REPORT PREVIOUSLY PROVIDED                                                                                                                    :
I i
J i
l CERTIFICATE OF COMPLIANCE We certify that the statements nude in the report are correct and this                REPLACEMENT confonns to the rules of the ASME Code, Section XL                                                                              Repair or RT= =- =t Type Code Symbol Stamp                                                                            - N/A l
l    Certificate of Authorization No.                                N/A                    Expiration Date                                      N/A Signed                            [          yJ                                        Date        by .J/                                    ,19 N owmr or ownes D=snai. Tan                                                              y i              D.B. Innax - Manager, Engmeenng Programs i
CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State                                        ,
or Province of                Arkansas                      and employed by                Factory Mutual Engineering Association                      .
of Norwood, MA                                                                                      m# have i                        the components described _          ,
in this Owner's Report during the period                            10/20/92                    to7/##' YNC ff (/#F/9/ ,and statethat                                      ,
to the best of my knowledge and belief, the Owner has performed examinations' and taken cirrective ' mea'sures described in this                                            l Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concermng the examinations and corrective measures described in this . Owner's Report. Furthermore, neither the Inspector nor his employer                                                i shallbe liablein any mannerforany personalinjury orproperty damageora lossofany kindarising fromorconnectedwiththis inspection.
i 9 . D. [                                                                    Commissions              NB-9947, Ark.-Il33 "N" , "I" , "A" g                                    #g                                                                    National Bo rd, State, Pnmnae, .nd Endon.mems Date      Qw              .2 A                      19 9 '/
61 l
 
                . _ . _ .                                . _ _ _            _                  _.            .          .                  ~._      _ _ _ . _            _,                    _.
l Page 1 (Front)
FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI-
: 1. Owner AP&I1Entergy Operations, Inc                                                                        Date        04/22/94 Name                                                                                                                i Rt. 3, Box 137G, Russellville, AR 72801                                                Sheet        1                    of      I M*=                                                                                                                    I
: 2. Plant                            Arkansas Nuclear One                                                      Unit            Two                                                l Rt. 3, Box 137G, Russellville, AR 72801                                                  JO# 00907981                                                      l Addrena                                                              Repar Organization P.O.No Job No sec.
: 3. Work Performed by AP&I/Entergy Operations,Inc                                                              Type Code Symbol stamp                    N/A Nam                                                Authorization No                          N/A Rt. 3. Box 137G, Russellville, AR 72801                                                Expriation Date                          N/A Meena
: 4. Identification of System M.S. ( 2 EBB-2 )
: 5. (a) Applicable Construction Code                          sun                    19 71            Edition, ' S-73                      Addenda, 1574              Codecase (b) Applicable Edition of Section XI Utilized for Repairs of Replacements 19                  86
: 6. Identification of Components Repairs or Replaced and Replacement Components 1
ASME Code National                                              Repaired,        Stamped Name of                  Name of              Manufacturer                  . Board          Other                    Year      Replaced,        (yes Component                      Manufacturer            Serial No.                      No. Identification              Built  or Replacement      or No) l                                8" GLOBE                        CROSBY                N58090-              N/A                  2PSV-1056                1979        PARTS              YES VALVE                                                  00-0012                                                                        REPLACEMENT l
                                                                                                              "'^
                                                \                                                            N/A
                                                                                                              "'^
l
(
N                                                                                                                                        ,
                    .7. Description ofWork REPLACED NOZZLE AND DISC INSERT
: 8. Tests Conducted                              Hydrostatic l        l Pneumatic l        l Nominal Operating Pressure l                    l Other R Pressure              N/A            Psi        Test Temp N/A                        F-
                                                                                                                                                                                                        ]
NOTE: Supplemental Sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is
                                            ' recorded at the top of this form.
l (12/82)                                                              This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 -
REPRINT 12/91
 
Page 1 (Back) i 4
FORM NIS 2 (Back)
: 9. Remarks REPLACED NOZZLE INSERT AND DISC INSERT waw. u. nut sura o.u n.pon. m 6. .num.4 NEW NOZZLE INSERT S/N N91560 0022 NEW DISC INSERT S/N N91562-37-0038 CERTIFICATE OF COMPLIANCE-                                                            _
i We certify that the statements made in the report are correct and this        REPLACEMENT conforms to the mies of the ASME Code, Section XI.                                                                  Repair or Replacement Type Code Symbol Stamp                                                                  N/A
                                                                                                                                                                    )
Certificate of Authorization No.                      N/A                    Expiration Date                                      N/A Signed          .  [+                [                                      Date        k ,,,,p  ,9)                              ,19 N owns or ownse. OEs'nn. T .
D.B. Lomox - Manager Engmeermg Programs p
CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of            Arkansas                  and employed by                Factory Mutual Engineering Association                          of Norwood. MA                                                                          AS# haveiped the componentsdescribed in this Owner's Report during the period                10/20/92                      to 7/7/#v fehO Tf' 9dff/99 , and state that to the best of my knowledge and belief, the Owner has performed examinations 'and then dorrective mciasures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer rnakes any warranty, expressed or implied, concerning the                                ,
examinations and corrective measures described inthis Owner's Report.Furthermore, neither the Inspector norhis employer                                          !
shallbe liable in any manner for any personalinjury or property damage or a loss of any kind arising from or connected with this                                j inspection.                                                                                                                                                    1 ll 1,b. [                                                          Commissions              NB-9947, Ark.-l 133, "N" , "I" , "A" g                                    g                                                            Nauanal Ba.rd, St.2, Provina, and Ende mares Date M                .7 A                  1999 v
j
 
1 i
Page 1 (Front)
!                            FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS I                                      As Required By The Provisions Of The ASME Code Section XI 4
,f 1. Owner AP&UEntergy Operations, Inc                                                      Date      04/22/94
:                                          N_
Rt. 3, Box 137G, Russellville, AR 72801                                                Sheet          1                of          1                      i
!                                          N 4  2. Plant        Arkansas Nuclear One                                                      Unit            Two                                                  !
f      Rt. 3, Box 137G, Russellville, AR 72801                                                JO# 00907981
!                                          Addren.                                                              Rapaar organusuun P.O.No., Job No..stc.            j j  3. Woik Performed by AP&IJEntergy Operations, Inc                                        Tme Code Symbol Stamp                      N/A l                                          N=                                                Authorization No                          N/A
: j. Rt. 3. Box 137G, Russellville, AR 72801                                                Expriation Date                          N/A                        ,
j                                          A4ar                                                                                                                    ;
3  4. Identification of System ' M.S. ( 2 EBB-2 )
,  5. (a) Applicable Construction Code        sm m                  19 7}        Edition, S-73                      Addenda, 1574                    Code case
)      (b) Applicable Edition of Section XI Utilized for Repairs of Replacements 19                  86 i
j  6. Identification of Components Repairs or Replaced and Replacement Components I                                                                                                                                                        ASME l                                                                                                                                                        Code l                                                                          National                                                  Repaired,          Stamped
!    Name of              Name of              Manufacturer              Board              Other                Year          Replaced,          (yes l    Component              Manufacturer                Serial No.              No. Identification                  Built      or Replacement        or No) 8" GLOBE              CROSBY                  N58090-              N/A                2PSV-1056            1979          REPLACED              YES l    VALVE                                        00-0012 l    8" GLOBE              CROSBY                N58090-              N/A                2PSV-1056            1979          REPLACEMENT YES V LVE                                        004)010 N/A
!                                                                        N/A N/A
: 7. Description of Work REMOVED EXISTING VALVE AND REPLACED WITH SPARE VALVE
: 8. Tests Conducted            Hydrostatic l            l Pneumatic l  l Nominal Operating Pressure l )(l                                                        l Other l      l Pressure 1000              Psi            Test Temp 545                      F                                    l NOTE: Supplemental Sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) informa-i      tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is J
recorded at the top of this form.
j  (12/82)                      This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 REPRINT 12/91 1                                                                                                                                                                  .
I
 
1-i~
: i.                                                                                                                                            Page1(Back) l7
.I-3 5'                                                                                                                                                          l 4                                                                              FORM NIS-2 (Back) i j    9. Remarks THESE RELIEF VALVES ARE REPLACED EVERY REFUELING OUTAGE p u-r% Den a.p== w .m m.d                                                    :
_ NPV-1 MANUFACTURERS DATA REPORT PREVIOUSLY PROVIDED I; -
b 4
i i
i                                                                    CERTIFICATE OF COMPLIANCE We certify that the staternents made in the report are coTect and this        REPLACEMENT ' conforms to the mies of the -
j      ASME Code, Section XI.                                                                    Repair or Replacement i
1 i
a j        Type Code Spubol Stamp                                                                    N/A i
j        Certificate of Authorization No.                            N/A              Expiration Date                          N/A Signed                              I          f)                              Date      [m          ,9 /                ,19 %
j I
ownerorowner Dosisna.Tnd D.B. Lomax - Manager, Engmeermg Programs y                                                      >
i j                                                        CERTIFICATE OF INSERVICE INSPECTION l        I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State
;-      or Prosince of            Arkansas                        and employed by        Factory Mutual Engineering Association                  of Norwood MA                                                                            Ag# haveinspected the componentsdescribed
      - in this Owner's Report during the period                      10/20/92                to 7/7/ff/ dd,"# 9ddf 9 , and state that to the best of my knowledge and belief, the Owner has performed examinations 'and talien corrective'mesIsures described 'in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
',            By signing this certificate neither the Inspector nor his employer makes any' warranty, expressed orimplied, concerning the 4
examinations and corrective measures described in this Owner's Report , Furthermore, neither the Inspector norhis employer j        shallbe liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
9.o. [                                                              Commissions          NB-9947, Ark.-l 13 3, "N" , "1" , "A" 4
g                                Inspasovs sipann J.O. Elhott nan Board, Sws, Pnmace, and Endonerness
{          Date Ow                  a p.                    19 9 V                                                                                      !
[                v
    ,  -. .              .                  , _ __          _ ~, ,
 
l 3
Page 1 (Front)
FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI                                                        l a
: l. Owner AP&IJEntergy Operations, Inc                                              Date      04/14/94 i                                              Name Rt. 3, Box 137G, Russellville, AR 72801                                      Sheet        1              of          1
.                                            me
: 2. Plant        Arkansas Nuclear One                                            Unit            Two Rt. 3, Box 137G, Russellville, AR 72801                                        JO# 00908463
;                                            Address                                                  Repar Orgamzation P.O.No., Job M.,etc.            l
: 3. Work Performed by AP&IlEntergy Operations, Inc                                Type code Symbol Stamp                N/A N w.*                                  Authorization No                      N/A Rt. 3. Box 137G, Russellville, AR 72801                                      Expriation Date                      N/A mes.
i
: 4. Identification of System N2 (2HBB-17)
: 5. (a) Applicable Construction Code        SECr. HI 19 74      Edition, S-74              Addenda,. N/A                    Code Case (b) Applicable Edition of Section XI Utilized for Repairs of Replacements 19        86
: 6. Identification of Components Repairs or Replaced and Replacement Components                                                                      ,
AShE Code National                                    Repaired,              Stamped Name of              Name of              Manufacturer            Board      Other              Year      Replaced,              (yes Component            Manufacturer              Serial No.              No. Identification        Built    or Replacement            or No) 1" CHECK              ROCKWELL                NA                  N/A        2N2-1              E          REPLACED                YES VALVE                                                                                              1972 1" CHECK              EDWARDS                22AEZ              N/A        2N2-1                1992      REPLACEhENT YES VALVE N/A N                                                          "'^
N/A
: 7. Description ofWork CUT-OUT AND REPLACED VALVE
  ' 8. Tests Conducted            Hydrostatic l        l Pneumatic l    l Nominal Operating Pressure l        l Other l      l Pressure N/A            Psi    Test Temp N/A                  F NOTE: Supplemental Sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
(12/82)                      This Form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N.Y.10017                    l l
REPRINT 12/91
 
Page 1 (Back)    l l
l FORM NIS-2 (Back) i
: 9. Remarks NPV-1 MANUFACTURERS DATA REPORT FOR REPLACEMENT VALVE ATTACHED                                                                                            j Applicable Manufacture's Data Reports to be anached I-                                                                                                                                                                        ,
i I.
1                                                                                                                                                                        ,
i                                                          CERTIFICATE OF COMPLIANCE -                                      ,.                                        ,
We cenify that the statements made in the report are correct and this              REPLACEMENT ' conforms to the rules of the ASME Code, Section XI.                                                                    Repair or Replacement i
                                                                                                                                                                        +
Type Code Symbol Stamp                                                                      N/A Cenificate of Authorization No.                        N/A                    Expiration Date                                  .'N/A
  ~
Signed              I/            ,                /J                          Date        b, J                                      ,19                        ,
              < OW or owner's Desinnee.TiUs          r                                        p D.B. Iemax - Manager, Engineering Programs a
CERTIFICATE OF INSERVICE INSPECTION                                                                                -
e 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State -                                l or Province of          Arkansas                      and employed by              Factory Mutual Engineering Association ..                              of Norwood, MA                                                                              Ap# haveinspected the components described                            -
in this Owner's Report during the period                  10/20/92                        to 7/7/f f fehMT 4' W//d99 , and state that '                            !
to the best of my knowledge and belief, the Owner has performed examinations and taken co'rrective measures described in this                                      i Owner's Report in accordance with the requirements of the ASME Code, Section XI.
i i
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective . measures described in this Owner's Report.Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this                                  (
inspection.                                                                                                                                                        I
!                                                                                                                                                                        b t
k, O. [                                                          Commissions                  NB-9947, Ark.-l133, "N" , "I" . "A" Inspector's Signature                                                    National Board, State, Province, and Endorsementa J.O. Elliott                                                                                                                        !
Date Qu 3                                        19 cf s;                                                                                                        ;
d                                                                                                                                                          :
E
                                                        ,          ,                                                                  -________.__________l
 
-                                                                                                                                                    .24.'r - /                                  \
                                                                                                                                              % '.72 M 2
                                                                                                                            ? AGE $0v2.
FORM NPV 1 N CERTIRCATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES
* As Required by the Provisions of the ASME Code. Section lit, Div.1
: 1. Manufactured my bWA**YALus a De.190D .E. .S Aounnas Sr:. ht ria; A/c 27d,03 (Name ano Address of N Certificate Moicer)
: 2. Manufactured for            b G 1P N b ##Afla E TIM 30 OcK 7.h bf Starsu) ;MS J91.5 o            '
(Neme eric Acoress of Pureneser or ow ner
: 3. Location of I..stallation        C= 17 mJm do t a-        A/ u e te4 r SrmTied Paitr- 6 r= u d Mf M /50 tNerne ano Acoresse
: 4. Pump of Valve                  UALVE                                  Nominal Intet Site            /              Outlet Size                                          /
l                                                                                                        oncm                                                                  onen i
l              (a) Model No. (b) N Certificate Holder's (c) Canadian Senes No.                    Serial                  Registration        (d) Drawing                                        (f) Nat'l.                      (g) Year        f I
or Type                      No.                        No.                  No.          {et Class                          Bd. No.                          Built (v        868 YTl                    ztAer                        NJA            D9I- zo709-ot                I                    1071                                1992 968 YT-1                  23 A&C-                        blM            D91- 2crin8-cI              I                        It)1L                            IG 9 s 3 (i2T (3)
(4)
(5)
(6)
(7)
(8)
(9)
(10) s.
{ " S1bP 0H * * < lln, Je tarief oescnotion of service for enica equipment was oes.gneca Eco se Marnensat Arusn Asksc 11T
* r*r f.'o . 5
* 17 Au.                                              .R O. *41L. = 20102                                                        ;
: 6. Design Conditions                    940              psi              700 (Temperatures y or valve Pressure Class                                        A DC                      (1)
(Pressures
: 7. Cold Working Pressure                  t4N psi at 1005.                '
: 8. Pressure Retaining Pieces
          -          Mark No.                            Ntatorial Spec. No.                      Manufacturer                                                          Remarks                ,
(a) Castings i
{                                                                                                                                                                                                l l
l I
(b) Forgings SA / OS                                                                                              Beav SPrR                                                            ntierry i once                                                                                    i 14 A k'                .SA I R.S                            TerAoin rontGE                                                % sea-2.01. 9 G,              A 5t S &nt LIL                          Cou urve .Sns s                                                  n i1 w l
(1) For manually operated valves only.
* Supplemental sheets in form of lists. sketches or drawings may be used provided (1) site is 81/2" x 11", (2) information in items 1,2,nd 5 on this Data Report is included on each sheet. and (3) each sheet is numbered and number of sheets is recorded at top of this form.
{
(10/77)                              This form (E000371 mov be obtained f rom the Order Dept., ASME,345 E. 47th St., New York, N.Y. 20017
 
    -.                .                      .                                  .  - - . .        .    -                                          . . ~  _
                                                                                                                                                          '2/AEZ I" **                      frfM I,Bisel Vai.ya 4/g 22 AE Manufacturer                Remarks Matenal Spec. No.
Mark No.
(c) Botting                                                                                                      De u ne J
                                                                                        \ %,rm Bour-PC I2.                AA I41              f:n 87 I
i                                                                                                                                                                  ,
4 (di Otner Ports I
I I
I i
l N M poi .
: 9. Hvorostatic test      IfSO esi.            Disk Difforentist test pressure                                                                .-
\                      .
'                                                              CERTIFICATE OF COMPUANCE' l
rules of We certify that the statements made in this report are correct and that this pump, or volve,                          /97conforms to th f                                                                                                                                                ,
construction of the ASME Code for Nuctear Power Plant Co .ponents. Section lit. Div. l Edition"I /L R /f L.
f                                                    , Code Case No.                    A          -
Addenda - N e eDeses      R/97N hy                  ht        SMA                                          >
Signed _ EN Af*D lla LU# C bt* -                                                                _
i 1
m con mcese        ri to use the    Y            symbol empires    11/2 L/% .
manei Our ASME Certificate of Authorization No. Al-7 5/.2                                            on CERTIFICATION OF DESIGN
[DWARD VA LWC D c._ Pau r if.nl. d d. 2*7/. dig Design information on file at Stress analysis report (Class 1 only) on file at __ EDWfth I/d d C E84 ; MAL #hfM_NO, Design specifications certified by (1)
Evu. TAaJAK A OA                    Reg.No.          I "I T/= 1 PE State Stress analys;s, certified by (1)
St A o4+tr T PE State        N 0-                  Reg.No.            NI87 f
(1) Signature not required. List name only.
l
* CERTIFICATE OF SHOP INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Soiler and Pressure Vessel inspectors and employed by . M M kE b-and the State or Province of Ale need Ca a e # e W l
have inspected the pump, of valve. Gescribed in this Data Report on of M A 9 Y s"a er 3 , U                                                                                                                                l 7 - 2 I 19 T 2 , and state thattothe best of my knowledge and belief,the N Certificate Holder has con-structed this pump, of valve,in accordance with the ASME Code, Section lit.
By signing this certificate. neither the inspector nor his employer makes any warranty, expressed or imp the ocuipment described in this Data Report. Furthermore neither the inspector nor his employer shall be liable in manner for an personapt i ry or property damage or a loss of any kind arising from or connected with this inspection.
M/                    7-2 Vjg 7 2 ,
Date                                                                                                4          MN Commissions -          men so. sisie. Prov. ano m                              4:
                        ~      ' /og'weien  v                                                                                                                  ..
                                                                                                                ~
                                                                                                                                            .______.m
 
Page 1 (Front)
FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI II l
: 1. Owner AP&IJEntergy Operations, Inc                                            Date    04/10/94 Name Rt. 3, Box 137G, Russellville, AR 72801                                      Sheet        1              of          1 Ahems l
: 2. Plant        Arkansas Nuclear One                                            Unit            Two Rt. 3, Box 137G, RusselMlle, AR 72801                                          JO# 00908465 AMress                                                    Repsa Orgamzauon P.O.No., Job No..etc.
: 3. Work Performed by AP&IJEntergy Operations,Inc                                Type Code Symbol Stamp              N/A Nana                                    Authorization No                    N/A Rt. 3, Box 137G, RusselMlle, AR 72801                                        Expriation Date                      N/A AMress
: 4. Identification of System SERVICE AIR (2HBB-7 )
: 5. (a) Applicable Construction Code        NA                  19 NA Edition, NA                      Addenda, NA                      Code Case (b) Applicable Edition of Section XI Utilized for Repairs of Replacements 19        86
: 6. Identification of Components Repairs or Replaced and Replacement Components AShE        ;
Code        ,
National                                  Repaired,              Stamped Name of              Name of              Manufacturer            Board      Other              Year      Replaced,      -
(yes Component              Manufacturer            Serial No.              No. Identification          Built    or Replacement            or No) t 3" PIPING              UNK.                  NA                  N/A        2HBB-7-3"          E          REPAIRED                YES          i' 1972 N/A
[
N/A                                                                                i N/A                                                                                ,
N/A
: 7. Description of Work PERFORMED NON-WELDED REPAIR TO PIPE
: 8. Tests Conducted            Hydrostatic l        l Pneumatic l    l Nominal Operating Pressure l        l Other l    l Pressure NA              Psi    Test Temp NA                  F NOTE: Supplemental Sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) informa-tion in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
(12/32)                      This Form (E00030) may be obtained from the Order Dept., AShE,345 E. 47th St., New York, N.Y.10017 REPRINT 12/91
 
l                                                                                                                                                                      I Page 1 (Back) l I
FORM NIS-2 (Back) l  9. Remarks RELOCATED NPT CODE NAMEPLATE TO ALLOW CUTTING OUT OF VALVE 2SA-69 Applicable Manufacture's Data Reports to be nuached
?
f CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this                    REPAIR        confonns to the rules of the ASIE Code, Section XI.                                                                          Repair or Replacement                                          '
i Type Code Symbol Stamp                                                                          N/A                                                            l
                                                                                                                                                                    ^
l Certificate of Authorization No.                          N/A                      Expiration Date                              N/A j  Signed                      I owneros%n e.o ian TV e
                                              ,        o                                Date            $-2                            ,19 %
t D.B. Lomax - Manager, Engmeenng Programs i
CERTIFICATE OF INSERVICE INSPECTION                                                                            !
!  I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State
!  or Province of                Arkansas                  andemployed by -                  Factory Mutual Engineering' Association .                    . of Norwood, MA AEF havejnspected the componentsdescribed in this Owners Report during the period                      10/20/92                          to 7h/99 Ydd# VIfF/W ,and statethat to the best of my knowledge and belief, the Owner has performed examinations and taken cofrective measures described in this .
Ownets Report in accordance with the requirements of the AShE Code, Section XI.                                                                                  i
!        By signing this certificate neither the Inspector nor his employer makes any warranty,' expressed or implied, mncerning the examinations and corrective measures described in this Owner's Report.Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personalinjury or property damage or a loss of any kind arising from or connected with this                                f inspection.                                                                                                                                                      '
h . D. b2 h                                                        Commissions                  NB-9947, Ark.-l133, "N" , "I" , "A" f                              gg                                                                        ~ ~ s m .e,.              .ano -
Date            8/3                              19 '/ Y l                                                                                                                                                                    J
 
aAw                    _2  ,h
* 4 c__,  4  m.        4    di  a  a.- , .              a    e  #      .r,s:  ..m s.  .ue..a i
i                                                                                                                                                                        l Page 1 (Front) i                            FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS                                                                                        l
-                                      As Required By The Provisions Of The ASME Code Section XI f
a j                                                                                                                                                                        l l  1. Owner AP&l/Entergy Operations,Inc                                                    Date      04/14/94.
]                                            Name
!      Rt. 3. Box 137G, Russellville, AR 72801                                            Sheet              1            of          I
* l                                          444,,,s j 2. Plant        Arkansas Nuclear One                                                  Unit                  Two
)      Rt. 3, Box 137G, Russellville, AR 72801                                              JO# 00908465 Addr,ss                                                              Repar Orgamzauan P.O.No.. Job No..stc.
I  3. Work Performed by AP&IJEntergy Operations, Inc                                      Type code Symbol Stamp                      N/A i
Nam
* Authorization No                          N/A j      Rt. 3. Box 137G, Russellville, AR 72801                                            Expriation Date                            N/A
                                          ^''""*
-j 4. Identification of System SERVICE AIR (2HBB-7 )
I j  5. (a) Applicable Construction Code        sum                    19 71. Edition, S-73                            Addenda, N/A                        Code case
.      (b) Applicable Edition of Section XI Utilized for Repairs of Replacements 19                86 i  6. Identification of Components Repairs or Replaced and Replacement Components i                                                                                                                                                            ASME Code National                                          Repaired,                Stamped i      Name of              Name of              Manufacturer                  Board        Other                  Year        Replaced,                  (yes 3    Component              Manufacturer            Serial No.                    No. Identification                Built    or Replacement                or No) i    3" CHECK              ANCHOR                2N-294                  N/A            2SA-69                  1974      REPLACED                    YES VALVE                  DARLING
!    3" CHECK              BORG                  7779                    N/A            2SA-69                  1976      REPLACEMENT YES
}    VALVE                  WARNER l  \                                                                      "'^
N/A l                                                                          .N/A i.
l 7. Description ofWork . CUT-OUT & REPLACED VALVE a
;  8. Tests Conducted            Hydrostatic l        l Pneumatic l X l Nominal Operating Pressure l                    l l                                Otherl      l Pressure 156                  Psi      Test Temp ~ AMB                    F NOTE: Supplemental Sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) informa-
.        tion in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is i        recorded at the top of this form.
(12/82)                      This Form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N.Y.10017 REPRINT 12/91 J
m    -. ~                    -.          ,                            --
 
                                                                                                                                                - Page 1 (Back) l l
l l                                                                      FORM NIS 2 (Back)
: 9. Remarks NPV-1 MANUFACTURERS DATA REPORT FOR REPLACEMENT VALVE ATTACHED Applicable Manufacture's Data Reports to be attuhed 1
                                                                                                                                                                -l L                                                                                                                                                                  j I
l CERTIFICATE OF COMPLIANCE'-
l                We certify that the statements made in the report are correct and this            REPLACEMENT conforms to the rules of the ASME Code, Section XI.                                                                    Repair or Replacement Type Code Symbol Stamp                                                                    N/A Certificate of Authorization No.                    . N/A                    Expiration Date                                N/A Signed                Ad Owrwhy Owner's Desiance.Taki /
                                                //                                Date            S-2                                ,19 94 l              D.B. lomax - Manager, Engmeermg Programs                                                                                                          ,
l                                                CERTIFICATE OF INSERVICE INSPECTION i
I, the undersign~t, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of          Arkansas                  and employed by              Factory Mutual Engineering Association                            of Norwood, MA Ldf ha- iyed the componentsdescribed in this Owner's Report during the period                10/20/92                        to7hh9 dyJC 7'/ WIfM9/ ,and statethat to the best of my knowledge and belief, the Owner has performed examinations and taken corrective ' measures described in this t    Owner's Report in accordance with the requirements of the ASME Code, Section XI.
!        By signing this certificate neither the Inspector nor his employer makes any warranty, expressed orimplied, concerning the -                            !
examinations and corrective measures described inthis Owner's Report,Furthermore, neither the Inspectar norhis employer                                      !
,    shall be liable in any manner for any personal injury or property damage or a loss of any- kind arising from or connected with this inspection.
l
;        k . C.      [M                                                Commissions                    NB-9947, Ark.-Il33, "N" , "1" , "A" g                                a'g                                                                National Board, State. Province, and DA . ;
Date    ,5~/3                              19 9'/
l j
 
_-__-_-_                              --~--                                            _              _
a l                    ;
t FORM NPV.1 MANUFACTURERS' D ATA REPORT                                                                                                                  7y 77 7 ey FOR NUCLEAR                    l f          g    /
P An Regstred by the Provistoss of the A94E Code Rate.                                                                                                                                      j
                                                                                                                                                                              -- ~ _._, __ __ _
___                                                                                                    I y              l J                                              Nuclear Valve Division                                                                                                                    46291 7500 Tvrope Ave . _ Van N as Ca __ order N,                                                                                                        3
: 1. Manuf.etured 6 _ af Bor:'_.Marnar_(m                                                            an Addr.ee ed Mmed c4.r.r)                                                                                                        -      l l
5      San Franc $ scoOder N, G600-M-21127-C.
: 2. Manor crured for Bechtel Power                                                                    cm . a Corp.
A44,...), P.O. Box 396 ,
Ca.                                                        ,
I r
Arkansas Power and Light Conipany f
M Ownet -                                                                                                                                                                                                                        ,
Little Rock, Arkansas N 4 Location of Plant                                                                                                                                                                                                                    g 73800, 3_Jnch Gate Valvo, CS, 300#
    '              O $. pur.p o Valee fdentification __ NV Division P/N Serial Numbers 7779                                                                                                                                                                .
                          ~
(B,4.f 4.scripil.n t ..rvice f.e which .quipe..a w.e dests. 4)                                                                _-
                                                                                                                                                                                                                                                            !i;f ;
N                                                                                                                                                                                                                                        $
O    ~
Nuclear Valve Division of Borg warner 73800                                              Picpared by                                                                                                                      .
mL c        (a) Drawing No.                                                                                                                                                                                                                k(m:g As                                                                                                                                                                                                                                                                !)
n
          .        O        (b) Rational Board No.                                                                                                                                                                                                        p'.g ig/.
720                                        _ ,,t 100                of                                                                                        . . - i 0    6. Deelsa Coadisias                                                  (Pr.o.w.)                                    (T          p.r.tur )
2 (W3                                                                                                                                                                                                                      -
: 7. The metesist, design. construction, and workmanship complies with ASME Code Section                                                                                                                    _
jQ!!!.l CIss QQ O                                        1971                          , Addenda Date _ Summer '73 _ , c,,, go,                                                                                                                          (m .Of i itM w                    Edition
                                                                                                                                                                                                                                                            ...,c
@m                                                                                                                                                                        w enur n.iur.,                  a  .,t.
                                                                                                                                                                                                                                                              &j; rg (
une,iansp e.it..                                                                                      -
If                                                                        v.eu N .
-Fa                                                                                                                                                                                                                                    __
Qi;)        ,                                                                                                                                                            ~                                                                                  is sA I fa) C.,rinas S
Gate - Code 1K06 SA351GRCF8M Waukesht: Fdy.
gjj Casting :-~~'7N15-11                                                                                                                                                                                            g!g
$[f g;          ,
72416-11                                                                              NV Division g            '
_Vachined -
:A yg J.;;.H
                                                                              -=                                                                                                                                                                                %
%q G
6                                                                                                                __ _ _ _              _ _ . . . . . .                                                                        -
                                                                                                                                                                                                                                                                'sh g
Wy 31i h
3%            :                              ._
__                g, tk%
nii e-g                              (b) F or ain e s Body - Code 1H37 SA-105
                                                                                                                                                                                                                                                                ' d.
Compton Forge
'h                                                Forging -                    72679-11 NV Division h{d Jj                                                                              72678                                                                                                                                                                          f,f Pf4 Machjy d_-.
72G77 NV Division                                                                              ,?
Atasembly -                                                                                                                                                                                                              I
_ Nec's = QM9 n,._
1J11                                                  SA-105 Compton Forge                                                  _ _ _ , _
lh f Ch !
      $                                            Foih'*7 ''' 72684-11                                                                                                NV Division                              -
4
                                                ~Eddnin M M 83-11 fi
> (f)            , ,
i
                                                                                                                                                                                      . e ..... en ,          :. . i. .. ..
                            .. u .. . ... ..,.                              .,u.....m...                              .      ..... ,              ..              .,,,e,..                  .
anu-n.,. .h..i.6. ..,4 4.
                                                                                                                                                                                                            ., tths.8.e=.                                        J'
        .4w .                                                                                                    ..se .m t. e cu ...n .h..        4..      % ,.a                                                                                              t n      iN. e.i.e.p.,ti.i.eius.4 4\
h 9i L r a...
q,w
% v~
n%
b* .,            +l.
                                  ~ . ..
s --
_ 5j
                                      ~ - - - -                                - - - - - _ . _ _ _ _ _ _ _ _ _ _ _
 
                                                                                                                                                                                                                                          +
u.=s.et.                                                    m m.,te-W.,s p..                        as...es.: sp.e. N l"
          )
l                      (c) Ahlag                                            ,
J-      364 typ 630 St ud - Code IJ98 Der Stock                                                            Du11 dor                        ,
Machined - 72183-11                                                                                                                                              _
l SA 194'Gr8m                                                                                                      _
l Fut - Code 1K47 f'
Ear Stock                                                            ibi l d oc-                                                                              --
hk 4 m ,4    - 791R4 11                                                                                                                                                                            r, (d) In m rr ux 1 Forgings (cont'd)
SA-105 O.                                  Bonnet ? Code 1G29                                                    Airto Viking T          _Forgine -            71945-11                                                                                                                                    . _ _
Machined -            72675-11                                        NV Division                                                                                ___
f                N l                                                                                                                                                                                                    _
L                Os
  ':j  ;
g 6
J g                                                                                                                                                                                                                                    %
    .-                    N                                                                                                                                                                                                                  6p
      $                                              1075-1125                                                                                                                                                                                      {
D Hydrostatie sea,                                  p,;,
[                                                                                                                                                                                                                                    n      -
t            ,
* CERDF1 CAT 10N OF DESIGN Y
P                                                        Nuclear Valve Div.. of Borg Warner. 7500 Tyrone Ave . Van Nuys. lle .
f                        Design information en file st OSeress analysis report on file Juelear Valve Div.. of Borg Warner, 7500 TyroneRe                                                                        Ave.,      Van  Nuy_s, Ca.                    ((3 Y                                                                        John Centles                              (1) Prof. Eng. Sense _ CA                                        g. No. 2371                                            ff
      ,[                    Design specifications certified by                                                                                                                                                                              IqI S. T. Yamahara                            (1) Prof. Eng. State _ CA                                    Reg.No. 23 521 RC                      OStress analysis repor certified by                                                                                                                                                                                  ;.4 DN!                      O(1) Signature not required. List came only.                                                                                                                                                                        '
4g                                                                                                                                                                                                                                    ,
D'y Fe certify that the statements nude in this report are correct.
Nuclear Valve Div.                                                                                                                                      p July 99                                    of Borr Warner                    By.          MW                                          .            WM Das,                          3976        Signed (u.avreeturera                                                        y                                                                          Q jdt.7 1254              ,, p i ,, ,
October 27, 1978                                                                                                                          h N
Certificate of Authorisation No._                                                                                                                                                    __
!,thd
%;p
't..
CERTIFICATE OF SHOP INSPECBON                                                                                                                                          Lj v                    -
d.4        .
                                                                                                                                                                                                                                                  ~
N                                I, the undersigned, holding a valid commission issued by the National Board California                      and employed by Dept.of Doller  sad Psessure of Bidr.                      Is Safety          VesselInspectors h
and/or the State of Province of hf            .-            og                    Ciy of los Angeles July 2 9,          ,19,7_6 have inspected the equipmens described in this Dets
                                                                                  , and siste shat to the best of my knowledge and belief, she Manuf aciarer Q
g 3?h:                          Report on has constructed this equipmt r. in accordance sich the applicable Subsections of s.SME Code, Section !!!.
7r
.d(.x; ing the equipment described in this Data Report. Furthermore neither the laspector nor his                                                                                                                        $ employ bi*j manner int any personal injury or property damage or a loss olany kind arising from or connected wieb chis inspection.
R1                                                                                                                                                                                                                                              4 WW 4,A N
3 W
/M$                            page            July 29                gg76 p
V h}$M                                                                                                                                                                                                                                              i M            .
M Commis sions                                                                                                                                      4
                                        .                                                                              (Nett.nel Beerpf 8tst.. Freeuwe an. No.)
%% ;.6                                          (Ins'P.eter)                                                                              -"*""                                                                                                    y 9%                                                                                                                                                                                                                                                t 33 u
{X pv                                                                                                                                                                                                                                                  k T'                          erw i. u.s.A. (enn                                            vw. r      <em i. .w.i    w. tr n aswa us s. no ai m.- v. =.x.v. soort                                                                                  g g, y.                                                                                                                                                                                                                                              !
@ A                                                                                                                                                                                                                                                  :
k.
b                    . .
: g. ."-..                -
v                                  p~.                                -
                                                                                                                                                                                                                            ~ ,. -~~
 
l l
Page 1 (Front)
FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS                                                                      l l                                      As Required By The Provisions Of The ASME Code Section XI
: 1. Owner AP&I1Entergy Operations, Inc                                            Date      03/10/94 l                                              Name Rt. 3, Box 137G, Russellville, AR 72801                                      Sheet        1                of        I
                                            ^'uras                                                                                                      l
<    2. Plant        Arkansas Nuclear One                                            Unit            Two                                                l l
Rt. 3, Box 137G, Russellville, AR 72801                                        JO# 00908746                                                      l Address                                                  Repa2r Orgaruzaban P.O.No.. Job No etc.
l    3. Work Performed by AP&IJEntergy Operations, Inc                                Type Cod: Symbol Stamp                N/A I                                            N=                                      Authorization No                      N/A Rt. 3. Box 137G, RusselMlle, AR 72801                                        Expriation Date                      N/A Addras
: 4. Identification of System HPSI(2CCB-14 )
!    5. (a) Applicable Construction Code        SECT m 19 $9      Edition, NO                Addenda, NA                        Code case i
j        (b) Applicable Edition of Section XI Utilized for Repairs of Replacements 19        86
: 6. Identification of Components Repairs or Replaced and Replacement Components AShE I
Code National                                    Repaired,              Stamped Name of              Name of              Manufacturer            Board      Other              Year        Replaced,              (yes Component            Manufacturer              Serial No.              No. Identification          Built    or Replacement            or No) l l
l
.      2" GLOBE              ANCHOR                  ET-724-2 8          N/A        2SI-69              1993        REPAIRED                YES
!      VALVE                DARLING l                                                                        N/A N/A N/A N/A
: 7. Description ofWork PERFORMED NON-WELDED REPAIR ON VALVE BODY
: 8. Tests Conducted            Hydrostatic l        l Pneumatic l    l Nominal Operating Pressure (          l Other l      l Pressure    NA          Psi    Test Temp NA                    F i        NOTE: Supplemental Sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
(l' 32)                      This Form (E00030) may be obtained from the Order Dept., AShE,345 E. 47th St., New York, N.Y.10017 REPRINT 12/91 l
l
 
              .    .              .                      .      .                                                -. -- ---                  . . ~ - - - _ _ .
Page 1 (Back) 1 I
I l
FORM NIS-2 (Back)
: 9. Remarks REMOVED LINEAR INDICATION FROM VALVE BODY AFTER WELDED INTO SYSTEM Applicable Manufacture's Data Repons to be enached i
CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and th                REPAIR                  confonns to the mies of the ASME Code, Section XI.                                                                    Repair or Replacement Type Code Sytnbol Stamp                                                                    N/A Certificate of AutLnationNo.                          N/A                    Expiration Date                                  N/A Signed                  If I,                                                Date            6 - 2.                                ,19        Q4 Owner ochwner's Desumse. TV '
D.B. Lomax - Manager, Engmeermg Programs CERTIFICATE OF INSERVICE INSPECTION
. I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State                                        i or Province of          Arkansas                  and employed by                Factory Mutual Engineering Association                                        of Norwood, MA JdF haveinged the componentsdescribed in this Owner's Report during the period                10/20/92                          to 7 h h 9 Y, h 6 7 / MW/f# , and state that to the best of my knowledge and belief, the Owner has performed examinations and tal[en corrective' measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.                                                                                          l By signing this certificate neither the Inspector nor his employer makes any warranty, expressed orimplied, concerning the examinations and corrective measures described in this Owner's Report.Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personalinjury or property damage or a loss of any kind arising from or connected with this                                          1 inspection.
9 . 0. [.// >                                                    Commissions                  NB-9947, Ark.-1133, "N" , "I" , "A"                                        l
  //                          Inspectvs Sipature                                                      National Board, State Provir.w, and Endorsemesas                      I V                              J.O. Elhott
                                                                                                                                                                              ]
Date      5/.3                            19 9 </
1
 
Page 1 (Front)
FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI i
: 1. Owner AP&I1Entergy Operations, Inc                                                                                                                      Date      03/10/94 Name Rt. 3, Box 137G, Russellville, AR 72801                                                                                                                Sheet        1              of        1 A4dren
: 2. Plant      Arkansas Nuclear One                                                                                                                        Unit            Two Rt. 3, Box 137G, Russellville, AR 72801                                                                                                                  JO # 00908746 Address                                                                                                                        Repair Orgamzatmn P.O.No.,Jub No.,etc.
: 3. Work Performed by AP&I1Entergy Operations, Inc                                                                                                          Type Code Symbol Stamp              N/A Nanw                                                                                                          Authorization No                    N/A Rt. 3, Box 137G, Russellville, AR 72801                                                                                                                Expriation Date                      N/A Addren
: 4. Identification of System HPSI (2CCB-14 )
: 5. (a) Applicable Construction Code            8M HI                                                                                19 89            Edition, NO                Addenda, NA                      Code Case (b) Applicable Edition of Section XI Utilized for Repairs of Replacements 19                                                                                  86
: 6. Identification of Components Repairs or Replaced and Replacement Components ASME Code National                                  Repaired,              Stamped Name of                  Name of                Manufacturer                                                                                  Board      Other            Year        Replaced,              (yes Coraponent            Manufacturer                  Serial No.                                                                                      No. Identification        Built    or Replacement          or No) 2" GLOBE              ANCHOR                      ET-724-1-1                                                                                N/A        2CV-5015-1          1994        REPAIRED                YES VALVE                DARLING
                                                                                                                                                "'^
  \                                                                                                                                            N/A N/A N/A
: 7. Description of Work PERFORMED NON-WELDED REPAIR ON VALVE BODY
: 8. Tests Conducted                  Hydrostatic l      l Pneumatic l                                                                          l Nominal Operating Pressure l        l Other l    l Pressure NA                                                                                    Psi    TestTemp NA                    F NOTE: Supplemental Sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) informa-tion in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
(12/82)                            This Form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N.Y.10017 REPRINT 12/91
 
Page1(Beck)
FORM NIS-2 (Back)
: 9. Remarks REMOVED LINEAR INDICATION FROM VALVE BODY AFTER WELDED INTO SYSTEM                                                                                  i Applicalde Manufacture % Data Reposts to be anached i
l CERTIFICATE OF COMPLIANCE We cenify that the statements made in the report are conect and th                REPAIR                    conforms to the rules of the -
AShE Code, Section XI.                                                                  Repair or Replacement Type Code Symbol Stamp                                                                    N/A' Certificate of Authorization No.                      N/A                    Expiration Date                                    N/A Signed                  f,./ [                                              Date '        SZ                                      ,19 94 Owner or/>wners Desianos. Title" '
D.B. Lomax - Manager, Engineenng Programs CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of          Arkansas                  and employed by                Factory Mutual Engineering Association                                of  !
Norwood, MA                                                                          ggf have 'nspected the components desenkd in this Owner's Report during the period                10/20/92                        to####                                FIId99 , and state that to the best of my knowledge and belief, the Owner has performed examinations and tak'en co'rrective mea'sures Mued in this OwTier's Report in accordance with the requirements of the ASME Code, Section XI.
Bysigning thiscertificate neitherthe Inspectornor his employer makes any warmnty, expressed orimplied,concerning the                                    i examinations and corrective measures described in this Owner's Report, Furthermore,' neither the Inspector nor his employer                                  j shall be liable in any manner for any personalinjury or property damage or a loss of any kind arising from or connected with this                            '
inspection.
: 9. O. [M                                                      Commissions                  NB-9947, Ark.-l133, "N" , "I" , "A"
(/                        Inspectors Sipature J.O. Elhott National Board, State. Province, and Endorsenwres Date    8/3                                19 '/ V                                                                                                      l i
l
 
i Page 1 (Front)
;                              FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS
;                                        As Required By The Provisions Of The ASME Code Section XI i
j  1. Owner AP&I1Entergy Operations,Inc                                              Date      04/05/94 j                                              Name a
Rt. 3, Box 137G, Russellville, AR 72801                                      Sheet        I                  of        1 i                                            Ad**=
l  2. Plant        Arkansas Nuclear One                                              Unit            Two e
;        Rt. 3, Box 137G, Russellville, AR 72801                                      JO# 00909000 & 00909001 Address                                                  Repair Orgamzauco P.O.No Job No.,etc.
l
: 3. Work Performed by AP&I1Entergy Operations,Inc                                  Type Code symbol stamp-                  N/A N=
[                                                                                    Authorization No                        N/A j        Rt. 3. Box 137G, Russellville, AR 72801                                      Expriation Date                          N/A Ad*e=                                                                                                        1 1
1
: 4. Identification of System HPSI (2CCB-7 )                                                                                                            l
:                                                                                                                                                        I
: 5. (a) Applicable Construction Code smrm                        19 89      Edition. NO                    Addenda. NA                  Code case  $
l (b) Applicable Edition of Section XI Utilized for Repairs of Replacements 19        86 s  6. Identification of Components Repairs or Replaced and Replacement Components                                                                      ,
l
!                                                                                                                                            AShE
!                                                                                                                                              Code i                                                                        National                                      Repaired,          Stamped Name of              Name of                Manufacturer          Board        Other                Year      Replaced,          (yes
;    Component            Manufacturer              Serial No.              No. Identification            Built    or Replacement        or No)
I i
2" GLOBE              TARGET                  6                  N/A          2CV-5055-1          1971          REPLACED            YES j    VALVE                ROCK i    2" GLOBE              ANCHOR                  ET-724-1 5        N/A          2CV-5055-1          1994          REPLACENENT YES I'    VALVE                DARLING j                                                                      N/A N/A N                                                  "'^
j  7. Description ofWork CUT-OUT                      REPLACED VALVE
: 8. Tests Conducted              Hydrostatic l )( l Pneumatic l      l Nominal Operating Pressure l            l Other l    l Pressure 2582          Psi    Test Temp AMB                      F i        NOTE: Supplemental Sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) informa-l        tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is i        ~ recorded at the top of this form.
(12/82)                        This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 REPRINT 12/91
 
Pcge 1 (Back)
FORM NIS-2 (Back)
!  9. Remarks NPV-I MANUFACTURES DATA REPORT FOR REPLACEMENT VALVE ATTACHED -
Applicable Manufacture's Data Reports to be attached l-l l
l l                                                      .
CERTIFICATE OF COMPLIANCE l              We certify that th, statements made in the report are correct and this              - REPLACEMENT confonns to the rules of the ASME Code, Section XI.                                                                        Repair or Replacement Type Code Spnbol Stamp                                                                        N/A Certificate of Authorization No.                            N/A                  Expiration Date                                        N/A Signed              8 /.                            A                            Date          S2                                        ,19 %                  '
ownfor owners Desianee'TW /
D.B. Lomax - Manager, Engineering Programs CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State o7 Province of            Arkansas                        and employed by            Factory Mutual Engineering Association                                of Norwood, MA                                                                                                    nsp in this Owner's Report during the period                      10/20/92                      to 7/W#44Ep have)#f~ged Y,              I MM/E    the ,componentsdescribed and state that to the best of my knowledge and belief, the Owner has performed examinations and taken cofrective measures described in this Oner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warrcnty, expressed orimplied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer
!'  shall be liable in any manner for any personalinjury or property damage or a loss of any kind arising from or connected with this inspection.
[
9.O.          b _ 2 /.c                                            Commissions                  NB-9947, Ark.-l 133, "N" , "I" , "A"
    //                                Inspectors Sipature                                                  National Board, State. Province, and Fadarsemerns v                                    J.O. Elliott Date      .5"/3                                      19 9 sf 1
 
PORM NPW1 CERTIFICAT1 HOLDER $' DATA REPORT NR NUCLEAR PUMPS OR VALVESP' j                              As Required by the Provienone of the ASME Code. Section Ill, DMelon 1                                                          I"#~ #~# ~
;                                                                                                                                            Pg.            of j
i
!          i,u,no, m w                      g      Anchor / Darling Valva Co. , 701 First St. . Williamsport PA 17701                                                                                  l
!                                                                                ===.w              .e=c                    n    m 1          2. Manute s. Entergy Operations Inc. , Rt.                                  3,. Box    137G.                    Russellville,    AR 72801 eum. .ns            .e ewv                        o.nni 3, % ,, m                      Arkansas Nuclear Cse, South 'of Jct. of Hwy. 64W & 3335, Russellville, AR j                                                                                          ,          ,,,,                                                            72801                          '
G8                            W9324157                                      ---
                                                                                                                                                ,            N/A 1
: 4. MmW No.. Sah No., w Type                                  %
          .s. m code, m m. m 1                                1989                      N/A                                        2                        N/A ie                      w e.ne.      e                              we      -
ec c eau
: s. Pume w e              Valve              N.,ense w , m            2"                  o,,, m                          2"
!                                                                                      su                            s                    ou l          7. m                y SA351-CF8M            ,,,,,          N/A                  gn,, A747-CB7-Clil-Q                                  N/A i                      w                          w                        w                                              km .                      W i                      cat.                        Neri                      noey                                          nonna                      tM.k j                    HohWe                    Board                      Sertal                                        Sortal                    $* rial j                  Setal No.                      No.                        No.                                            No.                        No.
!      E-T724 1                          N/A                            4                                              N/A            HT.fl9549 j    ' E-T724-1-2                            N/A                            si                                            N/A            HT.fl9549 j      E-T724-1-3                            N/A                            6                                              N/A            HT.#19549 j      E-T7 24- 1-4                          N/A                            7                                              N/A            HT.fl9549              _
j  (T-T724 5                              N/A                            R                                              N/A            HT.#19549                3
.        E-T724-1-6                            N/A                            Q                                              N/A            HT.fl9549 E-T724-1-7                            N/A                            11                                            N/A            HT.fl9549 i
* 4 4
4 h
1 I
j      *suossememes wtomwoon m tonn et nom, merches, w arewege eney be uses pnmose (It sue n e n = 11. tri hvormeoon e nome 1 eroven 4 1        on see Deta Report a mcsuess on esce sheet. (3) each emoet le numeoced and the nwneer of sheete se recorved et the too of tNs form.
(12/94)                    7hh h (E00037) eney be ottamed from the Creer Dept.. ASMt. 22 Low Detve, see 2300, Fer6.W. NJ 07007 2300.
1 i
  !                                                                                                                                                                                                      1 1
 
i PORM NPV-1 theski 1                                                                                                                                                                      .
s i              s. namede
: j.                                                                                                                                                            .
4
!              s. omdri esmeessie          2779            ,,              650              . , , .              ,,,                              1878    tu l                                        >= nem                      emme =neW 4507                                                          '
!.          Io cowworthspresswe                            ,,e n igo.,
1
: 11. Hymessedetest        6775            ,g,                                                  4958-l                                                          angdu,,,,en ,            -                                                                    ,,
j                    .                                                                                                                                        .
l                                                            cumRoanoN orosman                                                              .
{              os ,, % .,,ened b, William R. Rowlett,                                  Jr ,,,,,,,,,      AR 606 i              pedyi nopart eerened by Ronald S. Farrell                                    r.s. seen    PA        g ne. 1 16-E t
I g                                                        comncAn or Snor comumen                                                                                -
i'            We serivy est ee semesmome made h one report am seneet and that ets own, w vehe eenfonne se me rWee for eeneirucean
: i.            et me ASus code, seeden m. oMosen 1.
!              N Cereneses et Aumestenden W          N1712                                              espiree  4/15/95 noen    /~F N :-            sfor/Dar11na a c.eesem neem Vaive ComoanQmanas                  W s0r Ymdealtuu                                    ('v e          O                      ;
t a
* camRcAM oF SHOP 500P9eDON A
1
!            t, em undereisned. heidng a weed osmndosion leeued by es Nedend Board of Setor and Prenews Vened inspectore and
;            -em stow smsnmenee,          Pennsv1vania                              ende.,n,,edi,, Commercial Union Ins. Co.
i            e,              Boston. Mass-                              how inoposted en pump. or veen, deserned h mis osia neport on l            /o+ M A /'7 , is W, and etese est to es best of my knowies e end beast,                  s      me carencois Helder hee j            eeneeructed tNe pump, or vefwe. In esserdenes wtet the ASME Cette. Socilen M DMelon 1.
i                                                                                                                                                                            l
:            e rsayens ese serenamie, neenhor en hopeeser nor his empiover makes as weersney, espressed er homes, eenoeming v.
j            esmponent desorens h eis oeis neeert.                                                                                                                          j
                                                                  , nWeer ou inspector eer his emWeyw shed, be EeWe in any mannw fw
{            eny per enes key w preewty kind wisine from er conneemd with one hosmction.
no. /~7-W                                                            ..        __
Pennsylvania 2392 3                                      ' Cha'eGs iuuod                    /                      3"''''"""**"*"''"*""*"""*'"*"d"*1 j
(1) For manuesy operated veW,. enry.            V/                                                            .
]
4-I l~
l b
i i
1                                                                                                                                                                            l i                                                                                                                                                                            i
:                                                                                                                                                                          .l
 
l l
l Page 1 (Front)
FORM NIS-2 OWNERS RCPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI
                                                                                                                                                      ~
l
: l. Owner AP&IJEntergy Operations, Inc                                            Date      04/05/94 Name Rt. 3, Box 137G, Russellville, AR 72801                                      Sheet        I                of          1 m e.
: 2. Plant      Arkansas Nuclear One                                            Unit            Two
!    Rt. 3, Box 137G, Russellville, AR 72801                                      JO# 00909000 & 00909001 Address                                                  Repair Orgaruzation P.O.No., Job No.,etc.
l 3. Work Performed by AP&I1Entergy Operations, Inc                              Type Code Symbol Stamp                  N/A Name                                    Authorization No                      N/A Rt. 3. Box 137G, Russellville, AR 72801                                      Expriation Date                        N/A m e=
: 4. Identification of System HPSI (2CCB-7 )
: 5. (a) Applicahk Construction Code        smn                  19 89      Edition, NO                  Addenda, NA                        CodeCase (b) Applicable Edition of Section XI Utilized for Repairs of Replacements 19        86
: 6. Identification of Components Repairs or Replaced and Replacement Components ASME Code National                                      Repaired,              Stamped Name of              Name of              Manufacturer            Board      Other              Year          Replaced,              (yes Component            Manufacturer              Serial No.              No. Identification          Built      or Replacement            or No) l l  2" GLOBE            TARGET                  5                  N/A          2CV-5056-2          1971        REPLACED                  YES VALVE                ROCK 2" GLOBE            ANCHOR                  ET-724-1        N/A          2CV-5056-2          1994        REPLACEMENT YES l  VALVE                DARLING l                                                                    N/A N/A N/A
: 7. Description ofWork CUT-OUT & REPLACED VALVE
: 8. Tests Conducted            Hydrostatic l X l Pneumatic l        l Nominal Operating Pressure l          l Other l      l Pressure 2582            Psi    Test Temp AMB                    F NOTE: Supplemental Sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is l      recorded at the top of this form.                                                                                                                j i
(12/82)                      This Form (E00030) may be obtained from the Order Dept., ASME,345 E 47th St., New York, N.Y.10017 REPRINT 12/91 1
l 4
 
j Page1(Back)
FORM NIS-2 (Back) -
: 9. Remarks NPV-1 MANUFACTURERS DATA REPORT FOR REPLACEMENT VALVE ATTACHED -                                                                                ;
Apphcable Manufacture's Data Rcporta to be ansched 1
CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this          REPLACEMENT conforms to the rules of the ASME Code,'Section XI.                                                                  Repair or Replacement Type Code Symbol Stamp                                                                    N/A Ccitificate ofAuthorization No.                      N/A                    Expiration Date                                  N/A                        t Signed                  [c/ [.
Owner orbwner's Desianee. TC        f M                          Date            6 - f.                              ,19M4 D.B. Iemax - Manager, Engmeenng Programs                                                                                                        i CERTIFICATE OF INSERVICE INSPECTION                                                                          -
1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of          Arkansas                  and employed by                Factory Mutual Engineering Association                            of Norwood, MA                                                                          A&# haveinspected the componentsdesenhd in this Owners Report during the period                  10/20/92                      to7/7/W '/,p/d?f MN/99 , and state that to the best of my knowledge and belief, the Owner has performed examinations 'and tak'en co'rrective ' mea'sures described in this                        ,
Ownefs Report in accordance with the requirements of the ASME Code, Section XI.'
By signing this certificate neither the Inspector nor his employer 'makes any warranty, expressed or implied, concerning the examinations and corrective measures described inthis Owners Report.Furthermore, neither the Inspector norhis employer sha!! be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this                        )
inspection.
: 9. O.        [X3                                                Commissions                NB-9947, Ark.-1133, "N" , "I" , "A"                          !
Inspectes signature                                                    National Ikard, State. Provna, and Endorsernents f                              J.O. Elliott 1
Date      S/3                                  19 9 '/
1
 
l l
PORMAs NPV.1        Required by the  CERTIFICATE Provleions of the ASME Code.        HOLDERS'Section lit, Division CATA  1            RCPORT 3 VET-7.M-/-4h'OR Ps.            of i
i i, um ,,, m g                            Anc' hor / Darling Valve Co. , 701 First St. , Williamsport, PA 17701                                          ,
w          e      e.e = cerenc meni l      2. u.ns          ,,,w      Entergy Operations,Inc., Rt. 3.. Box 137G, Russellville, AR 72801 v e one .ee-o .e ewww., - o-wri
!      3,%,m                            Arkansas Nuclear One, South'of Jct. of Hwy. 64W & 333S, Russellville, AR
.                                                                                    .,,,,,, e,w .e.e                                                    72801 '
G8                            W9324157                          ---
                                                                                                                                      ,          N/A
: 4. Model No.. Sales No., or Type                                %
      .s. ASME Code, Secdon M. DMeien 1:                        1989                    N/A                          2                          N/A seemeni            see ne esaw                  isinew    -
scese case no.
I
: a. % or e                  Valve              N.,,,ww win t -        2'                    oudet eie.        2" ou                -                      ou 7 m s ,y SA351-CF8N                            w              N/A              m A747-CB7-CU1- %                              N/A
)i
!                    w                          a                            w                            te .                              Iel j                  Cart.                        Net'l                        medy                        Bornet                              Disk l                Hohner's                      Board                        Serial                      Swiel                            88W
!              8.rlal No.                      No.                          No.                          No.                              No.
I    E-T7 24- 1-1                              N/A                          4                            N/A                HT.#19549
  ' E-T724-1-2                                N/A                          F3                            N/A                  HT.#19549 E-T724-1-3                                N/A                          6                            N/A                HT.#19549 i    E-T724-1-4                                N/A                          7                            N/A                  HT.fl9549
:      E-T724-1-5                              N/A                          R                            N/A                HT.#19549 1  C E-T724-1-6                                N/A          -              Q                            N/A                  HT.fl9549              J l    E-T724-1-7                                N/A                          11                            N/A                HT.fl9549 i
I 1
s i
i
      *C
                ._.4 informonen Wi form of esta, sketenes, or erewange mey be used artrvedad (1) aise le 3 4 r.11. (2) Informecon en atoms i througn 4 on this Data Aeoort le inesuesd on eacn sheet. (3) each sheet is numeered and the numeer of sheets is recorood et the too of trus form.
(12/96)                      This form (E000371 may tie ootained from the Creer Dept.. ASME. 22 Law Ortwo. Son 2300. Fernsid. NJ 07007 2300.
 
_-      -- _        _ = .      .- -          .    --            .            .-.          - - . .
i                                                                                                                                                          i i
1 NNIM NPVo1 theski 2
i                                                                                                                                                      .
1 s
j      e, nemente                                                                                                                                  '
1 i
3                                                                                                                                                            ,
1                                                                                                                                                            1 1
(
: e. Deelen ennemens          2779          pd              650                                                    1878
                                    >= esse                  n==emesse
                                                                                  . , , , , , ,            g,,,                      m 4507                                                        '
to. cow % -                                        ,, ,ico.,
: 11. Hydesessetest          6775        ,it, m en,,,,,eg          ,,,                      4958 i
                                                                                                                                                              \
              ~
{                                                                                                                                            .
I c a m RCA11 oft 0F oE30We                                          .
i o,,,,                                                              Jr.,,,,,,,,,        AR o,,, ,,,      6436 j      o g,,mn,,,,
                  ,,ene,Ionald
                        ,,en g , S. FarrellWilliam R. Rowlett.,,g,g,,,,                        PA            su,. ne. 35216-E
[                                                            .
l                                                comncAT orsuorcouruanca                                                                          -
k j      we eeney ens am sensmenes made in ede esport om earme and met ese pump = ww.e eenferme to em ndes #w eenseveden i      of me Asus case, sessen m. owsien 1.
j      Ncwenameof Aummesedanp.              N1712                                            esperes      4/15/95                                            l l      o.,      /'7-9'/        1_      Anchor /Darlina Valve C=Mn.3,,og h d. /mdu4/4mv                                                              ('
;                                              a c.ea.s        =-i                                    noe  e          es        o                  +
1                                                                                                                                      .
i j                                                cemncATs or anorsospecT1on                                                                                  i s
13 es undereigned, heleng a veed esmmission leeued by the National Board of Boter and Pmesure VessefInspoeters and
      'en swiemennmon o,              Pennsylvania ensom,,,,,enfoamercialUnionIns.Co.
!      og                Boston. Mass.                                                                                .
have inspeceed me pump, or vove, desarmed in mie Date Report en
    /o+ U R /' 7 , is W. and state met se me best of my knoweedse end besef, me coronesse Heider has j    eenstructed this pump. or vefwe. In samordense with the AsMs Cado, seetten M. oMelon 1.
4 er eipens een aeroneses, nenhor me nmesesser nor No employer makes as warreney, eseressed er impsed. eene mine the j    eempenent deserted in ese one neeert.                . neimer the inspector nor Ne employer shed be Reble in any mennw tw                              l l      eny personal hfury er property                of      Idnd ereeing frern er eennected with this inspeeHen, on, /-7-9'/                                                      d _.        _
Pennsylvania 2392 i                                      Chise 1oud ' /                                I""'888"'"**''""'*"'''''""""""'"*"*3
                                                        ~
(1) For manuesy operated velves only.
1 5'
i 1
i,
 
Page 1 (Front)
FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI
: 1. Owner AP&UEntergy Operations, Inc                                            Date      04/05/94 Name Rt. 3, Box 137G, Russellville, AR 72801                                      Sheet        1              of        1 m e.
: 2. Plant      Arkansas Nuclear One                                              Unit            Two Rt. 3, Box 137G, Russellville, AR 72801                                      JO# 00909000 & 00909001 Address                                                  Repair Orgamzataan P.O.No.,Jub No.,etc.
: 3. Work Performed by AP&UEntergy Operations, Inc                                Type Code Symbol Stamp                N/A Name Authorization No                    N/A Rt. 3. Box 137G, Russellville, AR 72801                                      Expriation Date                      N/A m en
: 4. Identification of System HPSI (2CCB-14 )
: 5. (a) Applicable Constmetion Code sECTlH                      19 89      Edition, NO                  Addenda, NA                      Code Case (b) Applicable Edition of Section XI Utilized for Repairs of Replacements 19        86
: 6. Identification of Components Repairs or Replaced and Replacement Components AShE Code National                                    Repaired,              Stamped Name of              Name of              Manufacturer            Board        Other            Year        Replaced,              (yes Component            Manufacturer              Serial No.              No. Identification        Built    or Replacement            or No) 2" GLOBE            TARGET                  4                  N/A          2CV-5015-1          1971        REPLACED                YES VALVE                ROCK 2" GLOBE            ANCHOR                  ET-724-1-1          N/A          2CV-5015-1          1994        REPLACEMENT YES
' VALVE              DARLING N/A N/A N/A 1
: 7. Description of Work CUT-OUT & REPLACED VALVE
: 8. Tests Conducted            Hydrostatic l X l Pneumatic l        l Nominal Operating Pressure l          l Other l      l Pressure    2403        Psi    Test Temp AMB                  F NOTE: Supplemental Sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
(12/82)                      This Form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N.Y.10017 IEPRINT 12/91
 
Page 1 (Back) l l
[
l
;-                                                                                FORM NIS-2 (Back)                                                                              ,
l;                                                                                                                                                                                >
l
: 9. ' Remarks NPV-1 MANUFACTURERS DATA REPORT FOR REPLACEMENT VALVE ATTACHED Applicable Manufacture's Data Reports to be enached s
l                                                                                                                                                                                  !
l CERTIFICATE OF COMPLIANCE l                  We certify that the statemems inade in the report are correct and this -                REPLACEMENT conforms to the rules of the ASME Code, Section XL                                                                            Repair or Replacement t
Type Code Symbol Stamp                                                                          'N/A Certificate of Authonzation No.                              N/A                    Expiration Date                                      N/A
      ' Signed            _      d/ d Owns of Oueer's Destanee. TC /
_a                            Date        S - 7. -                                  ,19 %
D.B. Lomax - Manager. Engineenng Programs CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State                                        ;
or Province of          Arkansas                          and employed by -            Factory Mutual Engineering Association                                  of
                                                                                                                                                                                  ^
Norwood. MA                                                                                    Me havejnspeged the components desclibed in this Owner's Report during the period                      10/20/92                      to 7 h /f / 6 O 7 i #/M/99 , and state that to the best of my knowledge and belief, the Owner has performed examinatioris 'and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
Bysigning thiscertificate neitherthe Inspectornorhis employer makes any warranty, expressed orimplied,concerningthe examinations and corrective measures described in this Owner's Report.Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
k.O          bM-                                                      Commissions              NB-9947, Ark.-1133, "N" , "I" , "A"
        'g                          Inspector's Signature J.O. Elhott National Board, Staic, Province, and Endorsements Date      5/3                                      ' 19 't I/
 
4
,            FORM NPV 1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS CR VALVES
* 7##-50'S ~/
;                            As Required by the Provisions cf the ASME Code. Section ill, DMalon 1                                        FN E 7- 7/ /-/-/
P9-            of                i 3
I 3, um ,,, m g Anchor / Darling Valve Co. , 701 First St. , Williamsport, PA 17701
;                                                                          ==. .n me        er n e,one somni j        2, www Entergy Operations,Inc. , Rt. 3.. Box 137G, Russellville, AR 72801
;                                                                  o-. ans me        ee purce      o.nni                                                    ,
j      g%,m                            Arkansas Nuclear One, South of Jct. of Hwy. 64W & 3335, Russellville, AR                                              l
.                                                                                            .e                                                  72801      <
: 4. Model No.. Series No.. or Type GB                          W9324157                        ---
N/A j                                                                  Drewtng                        Rev.                        CAN f      .s. AsME code. Secean m. DMaion 1:                    1989                  N/A                        2                          N/A 4
semese            imme nes ee w                ww        -
sca.c w
;      e, un, ., %                Valve              we                    2"                  w ,,,,            2" ou                                    ou
.      7, m ,,,,SA351-CF8M                            ,,,,,,      N/A              m A747-CB7-CU1- Q                              N/A i
I                  W                            tw                        w                          se .                          w
.              Cert.                        Not1                      Body                      Sonnet                          06d j              Holder's                      Soard                    Serial                      Sortal                        Serial                    ;
l            Seriol No.                      No.                        No.                        No.                            No.
(E-T7 24-1-1
  ' E-T724-1-2 N/A N/A 4                            N/A              HT.#19549              )
R                            N/A              HT.#19549 E-T7 24 3                          N/A                          6                            N/A              HT.#19549 E-T7 24- 1-4                            N/A                        7                            N/A              HT.#19549                            !
E-T7 24 5                          N/A                        R                            N/A              HT.#19549
!    E-T7 24 6                          N/A                          4                            N/A              HT.#19549 l    E-T724-1-7                              N/A                        11                          N/A              HT.#19549 i
l t                                                                                        _
                                                =
r I
i i                                                                                                                                                            !
I i
i i
_a informenen in form of nets. amerenes, or eewege mey t. uses prev =see 111 eue to a n = 11. (21 mformenon m nome i tnrough 4 on tree Osta Aeoort w e aon each eheet.13) each sheet te nummered and the numeer of sheets is recorded et the top of this form.
(12/961                    TNe form (E00037) mey be octaned from the Orcer Deot.. ASME. 22 Law Ortve. Bos 2300. Forfwd, NJ 07007 2300.
d i
?
 
I
;                                                            PORM NPV.1 (booW i
:      a. nemerte                                                                                                                                            '
                                                                                                                                                                -    I 1                                                                                  .
I i      s. onderi earnede,.          2779                            650
                                                        ,,                            ., , %                g,,,          1878 lares.ww                    ta= eene                                                              fu io, cowwortanepresswo              4507              ,,o, ion.,
!    11. Hyte sede test        6775            g u                                                4958 d,,,,,,,,
(            -
i d
,                                                        campicAitom orosasen                                            .
i      w m ewdned w William R.'Rowlett, Jr.,,,,,,,,,                                            AR
                                                                                                              , , , , , 6436 ossion neport ewoned try      Ronald S. Farrell                              P.E. sarm  PA            g, ne, 35216-E 4                                                                                                                                                                      j
: i.                                                              .
1 l
1 a
i camncAT orsHopcotAPt.LUect
* i i
j We certify Wiet sie sestamerite made in tNo report are correct ered Wiet tide purvia er vefwe eerderms to the ruise for eenstruction i      et om AsME come, section m, o6viesen 1.
j      N carensen of Austwineden No            N1712 Empiree      4/15/95 o,,,  / 9'/      1_        Anchor /Darlino Valve Cmn.gi,ned A d. Ymduud4mv                                                                      f' 4                                                se c.enesis nos.ri                                sesei.n.wr - .es U                              -
I                                                                                                                                                            -
j                                                                                                                                      -
l
:
* camncATs or sHopsospecTion a
i, em undereiened. hakenePennsv1yan1a a vend sommission leeued try the Nedenal Board ef Senor and Preenwe Vened inspectore and wie suria mesnemone ,,,
                                                                          - and empsey,,d n,Commereial Union Ins . Co.
l    et              Boston. Mass.
have inspected the pump, er ves , descreed in tNo oste neport en l
    /O-d-U R /-7 . is W, and state that to the best of my i2J :_ sad benef, the c.encate Heider hee sonstructed 1No pump, or verve, in accordenes with the AsME Code, section lH. Divielen 1.
i Dy signine tNo cartsnosto, netther the Inoposeer nor No employer makes any warranty, expressed er Impiled, eencaming the
,'  componeret descrhed in tNo oste neport.
ormere, nehher the inspector nor his empieyer ehes, he Rohde in any menner for i    eny pereenet ir4ury or property                    of    kind arising from er connected with tNo :.- ; f-o,. /-7-9V                                                      -
Pennsylvania 2392 w
;                                      com e
                                                                                          - es. - - .i.ie .r _. .r,e n..,
4 (1) For menue#y operated vefwee only.            Yf                                                              -
i i
e i
)
4
 
a j                                                                                                                                        Page 1 (Front) j                            FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI 5
1 4
i  1. Owner AP&I1Entergy Operations, Inc                                            Date        04/05/94 i                                            Name Rt. 3, Box 137G, Russellville, AR 72801                                      Sheet        1                    of        1 i                                          m.
j 2. Plant _ Arkansas Nuclear One -                                                Unit            Two i      Rt. 3, Box 137G, Russellville, AR 72801                                      JO# 00909000 & 00909001
$                                          Address                                                    Repair Orgamzauan P.O.No Job No., sic.
l  3. Work Performed by AP&I1Entergy Operations, Inc                                Type Code Symbol Stamp                    N/A Nme                                    Authorization No                          N/A
]
}      Rt. 3. Box 137G, Russellville, AR 72801                                      Expriation Date                          N/A
                                          ^""''
5
{ 4. Identificationof System HPSI(2DCB-3 )
i j  5. (a) Applicable Construction Code smin                        19 89      Edition, NO                        Addenda, NA                  code Case j      (b) Applicable Edition of Section XI Utilized for Repairs of Replacements 19          86 4  6. Identification of Components Repairs or Replaced and Replacement Components i
f                                                                                                                                                AShE Code National                                          Repaired,          Stamped i      Name of              Name of              Manufacturer            Board        Other                  Year      Replaced,            (yes j    Component            Manufacturer              Serial No.            . No. Identification              Built    or Replacement          or No) i 2" GLOBE            TARGET                  3                  N/A          2CV-5016-2                  1971      REPLACED            YES j    VALVE                ROCK
!    2" GLOBE            ANCHOR                  ET-724-1-2        N/A          2CV-5016-2                  1994      REPLACEhENT YES
:    VALVE                DARLING N/A N/A l  7. Description of Work CUT-OUT & REPLACED VALVE i
: 8. Tests Conducted            Hydrostatic l )( l Pneumatic l      l Nominal Operating Pressure l                l j                                Other l      l Pressure    2403        Psi    Test Temp AMB                        F NOTE: Supplemental Sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) informa-j      tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
j  (12/82)                      This Form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N.Y.10017
+
REPRINT 12/91 4
 
Pege 1 (Back) 2 4
i FORM NIS~2 (Back)
: 9. Remarks NPV-1 MANUFACTURES DATA REPORT FOR REPLACEMENT VALVE ATTACHED Applicable Manufacture's Data Repsts to be attadied P
CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this          REPLACEMENT con ms to the rules of the
  ' ASME Code, Section XI.                                                                  Repair or Replacement.
Type Code Symbol Stamp                                                                  N/A Certificate of Authorization No.                      N/A                    Expiration Date                                            N/A Signed                8 d,                        />                          Date                    5        ~2                            ,19 9 4 Ownerbr Owner's Destanee. TC - /
D.B. lomax - Manager, Fagineenng Programs CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of            Arkansas                    and employed by              Factory Mutual Engineering Association                                          of Norwood. MA                                                                                                                  ed the componentsdescribed in this Ownefs Report during the period                10/20/92                            AAF have ny#.Ghp 9I' MW' , and state to 7/7/W I                                                                      t to the best of my knowledge and belief, the Owner has performed examinations and taken corrective nicasures described in this Owners Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed orimplied, concerning the examinations and corrective measures described in this Owner's Report, Furthermore, neither the Inspector not his employer shall be liable in any manner for any personalinjury or property damage or a loss of any kind arising from or connected with this inspection.
I 4
k . C.        bM                                                Commissions                      NB-9947, Ark.-1133, "N" , "I" , "A"
    #-                        inspector's Signature J.O. Elliott National Board, State, Province, and Endorsements Date        S/3                                19 'f8/
 
  . _ _ _ _. . . _ . . - . _ .                              _.                              --                            -~
i                                                                                                                                                            2CV-s cie - d
;                          PORM NPV.1 CERTTPICATE HDLDERS' CATA REPORT POR NUCLEAR PUMPS CR VALVES'a/, j 7 7pg _.j_y                                                          l As Required by the Provisions cf the ASME Code. Section IN, DMelon 1                                                                    l of Pg.
              ',, w . m m w Anc' hor / Darling Valve Co., 701 First St., Williamsport, PA 17701 owns ans emmen e a c ness, nonni
: 2. -,,, Entergy Operations,Inc. , Rt. 3.. Box 137G, Russellville, AR 72801 w no ens seeen w rweheen n own.
g %,                            Arkansas Nuclear One, South 'of Jct. of Hwy. 64W & 3335. Russellville AR e one e                                                          72801 GB                            W9324157            ,
                                                                                                                                                ,          N/A
: 4. nameene . s.tes No.. er ry,.                                ,,,,,,,
                .s. ASaas case, secean m. oMaion 1:                    1989                    N/A                            2                          N/A                ,
l issess                iseannesessu                  wese      -
scene c.e w
: e. pu,,, ,, m              Valve              no,,,,,, e              2"                    w ,,,              2" ou                s                    ou
: 7. Motorial: Boey SA351-CF8M                  ,,,,,,          N/A              g,,    A747-CB7-CU1- Q                          N/A w                        w                            w                            w.                              W                        i Can.                    Mm1                          Boey                        Bonna                            Disk l
Heider's                  Gosse                        Sertal                        Serial                          Sortel                    I Sortal No.                  No.                          No.                          No.                              No.
1 E- T724 1                          N/A                            4                              N/A                HT.fl9549
                                                                                                                                                                -)
          '(E-T724-1-2                                N/A                            5                              N/A                HT.#19549 E- T7 24 3                          N/A 6                              N/A                HT.#19549 E- T7 24- 1-4                          N/A                            7                              N/A                HT.#19549 E-T7 24 5                          N/A                            R                              N/A                HT.fl9549 E-T724-1-6                              N/A                            Q                              N/A                HT.fl9549 E-T724-1-7                              N/A                            11              .,,          N/A                HT.fl9549
* Sussesmentes informonen h form of tots. sketches, or eowngs may be used prowesed (1) sae le 0 % = 11. (2) informsoon in items 1 througn 4 en tree Data Report to anoused on eacn sneet. (3) each eneet le numeered and the nurnest of oneets is recorood et the too of true form.
(12/941                    This krm (E00037) may be ontemed fmm the Order Dept.. ASME. 22 Law oftve. 50s 2300. Fernand. NJ 07007 2300.
 
i MHtM NPV-1 lbook) i i
!          s. nemens                                                                                                                                      '
o j
!                                                                                                                                                                  j
!          e. % eseiseesis              2779              Pd              650              .,,,,,,,,                  ,,,,,        1878 ie=seem                                                                                                    n,              l
}                                                                      ameeres w j        io, cand wemme -                '4507                g , iao., -
;        11. Hydressmestest        6775            g m e ,,,,,,,eg ,,,, ,                                  4958
(                                                                                                                                                    .
1 j
i                                                            cammcADoN orcemen                                                    .
l l          oemen w eseemed                    William R. Rowlett, Jr.P.a. m                                AR
                                                                                                                        %            6436 1
a myi nspers serened by        onald S. Farrel1                                P.E seses        PA          m,. no,    35216-E-2 1
;                                                      ceKTIRcATE or SHOP COMPUANc3
* i
}        We corolfy sist the steesmente made in this report are oorme' g er volve eenferms to the ndes for eenstruetion i          et sw AsME code, seseen m. oMeien t.
j          N cweneses of Aumansesen
* N1712                                                  esperse    4/15/95
                  / f'/ -
4 o,,                            Anchor /Darlino Valve Compan.g no, h S. ImdeAt/4ev                                                              ''
se cansamens Meneeri
!                                                                                                              isomennee emersesrome.w U                  -        >
i                                                                                                                                                              -
:                                                                                                                                                                  t I
4
;                                                . commcATE OP SHOP 56SPECDON t
]
I, ou undersigned hetens e vend eneminalen issued by the Noennel toeni of Gener and Pmesure Vessel inspectore end i        me steie moreNGdW6 o,          Pennsylvania                                endom,isyedi,,Cornercial Union Ins. Co.
i        se              Boston. Mass-                                                                                        ,
I                                                                        have inasmeted om pump, or valve deserted in mis este neport on
'        /o+ M R /-7 . Is W. and etets that to the best of my Mr._ and benef, the certmcate Holder hee eenesuceed mis pump, er ve#ve, in essensense with em AsME code, seceen m. DMalen 1.                                                                      '
i er etydne mis aeroneses, neither the insposter nor'his employer makes erk warrenty, empressed er impsed, concoming the I        component described in mis osis neport.
                                                                  , neether the inspector ner his employw shes be neb 6e in any mennw for
!        eny pereenet infury or propwty                    of      kind arising troen or connected whh mio inspection.
no. /-7-9V                                                                - . e.,            Pennsv1vania 2392                                          i i                                        Cha?&1 isuol '                                          "'*********''*'"*"***'''***'"*'''"e.n                            1 i
{      111 For menuesy operstod velves only.          V/                                                                .
4 j
i 4
)
4 i
I,
 
Page 1 (Front)
FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI
: 1. Owner AP&L/Entergy Operations, Inc                                            Date      04/05/94 Name Rt. 3, Box 137G, Russellville, AR 72801                                      Sheet      1              of        1 Address
: 2. Plant        Arkansas Nuclear One                                              Unit          Two RL 3, Box 137G, Russellville, AR 72801                                        JO# 00909000 & 00909001 Address                                                    Repas Organnadan P.O.No., Job No.,etc.
: 3. Work Performed by AP&I1Entergy Operations,Inc                                Type Code Symbol Stamp              N/A Nanw                                      Authorization No                    N/A Rt. 3, Box 137G, Russellville, AR 72801                            _
Expriation Date                    N/A Addre
: 4. Identification of System HPSI (2CCB-12 )
: 5. (a) Appbcable Construction Code        sum                  19 89      Edition, NO                Addenda, NA                      Code case (b) Applicable Edition of Section XI Utilized for Repairs of Replacements 19        86
: 6. Identification of Components Repairs or Replaced and Replacement Components AShE Code National                                  Repaired,              Stamped Name of              Name of              Manufacturer            Board        Other            Year        Replaced,              (yes Component            Manufacturer              Serial No.              No. Identification        Built    or Replacement            or No) 2" GLOBE              ANCHOR                  ET-724-2-1          N/A        2SI-68              1993      REPLACEhENT YES VALVE                DAPLING 2" GLOBE              ANCHOR                  ET-724-2-3          N/A          2SI-70              1993      REPLACEhENT YES VALVE                DARLING N/A N/A N/A
: 7. Description ofWork INSTALLED NEW VALVES INTO SYSTEM
: 8. Tests Conducted            Hydrostatic l X l Pneimiatic l        l Nominal Operating Pressure l        l 2403        Psi    Test Temp AMB                  F Other ] Pressure NOTE: Supplemental Sheets in fonn oflists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) informa-tion in items 1 through 6 on this r. port is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
(12/82)                      This Form (E00030) may be obtained from the Order Dept., AShE,345 E. 47th St., New York, N.Y.10017 i
REPRINT 12/91
 
Page 1 (Back) i l
I l
1 l
FORM NIS-2 (Back)
: 9. Remarks NPV-1 MANUFACTURES DATA REPORTS FOR NEW VALVES ATTACHED Applicable Manufacture's Data Reports to be suached i
t                                                                                                                                                                          ,
l CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this            REPLACEMENT conforms to the rules of the ASME Code, Section XI.                                                                      Repair or Replacement Type Code Symbol Stamp                                                                        N/A Cenificate of Authorization No.                        N/A                      Expiration Date                                'N/A Signed                  I[
Owner eft Owners Desiance. Title
                                                        /)                              Date            5      2.                            ,19 'I4 D.B. Immax - Manager, Engincenng Programs l                                                      CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of            Arkansas                    and employed by                Factory Mutual Engineering Association                              of Norwood, MA                                                                                A 42# have                ed the componentsdescribed
(      in this Owner's Report during the period                10/20/92                          to 7/7/9f/ #dyiff~h' '/IfV/9ff , and state                        that l      to the best of my knowledge and belief, the Owner has performed examinations a'id takeft corfective nicasures &KWued in this l      Owner's Report in accordance with the requirements of the ASME Code, Section XI.
l          By signing this certificate neither the inspector nor his employer makes any warranty, expressed orimplied, concerning the l      examinations and corrective measures described in this Owner's Report.Furthermore,' neither the Inspector.norhis employer shallbe liableinany mannerforany personalinjury orproperty damageora loss ofany kindarising fromorconnectedwiththis inspection.
9    O,      [M          Inspectors Signature Commissions                  NB-9947, Ark.-l l33, "N" , "1" , "A" National Board, State, Province, and Endorsernents
      //
v                                J.O. Elhott Date      S/3                                    19 9 t/
i
 
}
                                                                                              -                                              of3Z- fI$
l                PORM NPV-1 CBmPICATE HOI.DERs' CATA REPORT POR                                                    NUCLEAR PUMPS CR VALVEt*k A. Reque.d by *. P=vw.a. .e m. AsME Cee., s e m. oivw i Ps.          of
/                                                                                                                                                .
4 i
j
: i. namissemees w earenes ty Anc' hor / Darling Valve Co. 701 First St.. Williamsport. PA 17701
                                                                                ==mo        me w a c.usem.,=M i
: s. ns weeneesser.galprov Doerations. Inc., Rt. 3. Box 1376. Russellville, AR 72801                                                          ,
in    ==ses==wmen          .        e                                                  '
: s. i.sosennetkisionamen Arkansas Nuclear One, South of Jct. of Hwy. 64W & 3335 Russellville,                                          /2801 AR ens. o s.ee e                          .                                    l j                                                                                                                                          N/A
: 4. namens % sede. No., er vyys                  AB            o,eistis    W9324158          n,,,        -_
l
                                                                                                                                                                  )
l
;                                                                                                                  2                      N/A
          .s.~ isas code, sessen m, osse.non 1:                  1989                    N/A 1
esenen              e.es e.eu.                ens.    -
sc.e ca .ea I
valwe                                      2'            ouemm                  2"
: s. Pueservene                                  Numiiss asism -
  }                                                                                  ena                                ou i
son,        N/A                gi,g SA564-630-110 Q                  N/A I          7. namendet see, SA38st-CF8M let                          M                        M                          M.                        lel 80sti                      Body                      Bennet ,                  Disk Cert.
* Board                      Sess                      Serial                    Sedel HeMar's SedelNo.                        Ite.                      No.                        Ms.                      80 s.
                                                                                                                                                  )
  !,                                                t /A                    2874                        N/A                /C A668                            ,
    *{E-T7 24-2-1 /                                                                                      N/A
                                                                                                                              /C A668 i        E-T724-2-3 7                              I  /A                    2881                                                                                1 E-T7 24-2-4 /                            t /A                    2882                        N/A            "/C A668                              l E-T724-2-6 7                              k/A                      2883                        N/A            "/C A668            e                  !
E "724-2-7 / ,                            N/A                      2886                        N/A            "/C A668 l'-                                                                                                        N/A            "/C A668 J.
E-"724-2-R V                              N/A                      2887 I
i J
i                                                          _
1 i
i                                                                                                                                                                i l
4
              *su e m.nw wennseen m sean w em mm                  .e m m        m      e e, eems sti m.m am x t1. im wennseen mi.m. t e en 4 en en.        n n a me e en n en . im n en.m m n                    e one me ne , w en      me      e a e me w en s nn.
j n-                            1,s. - i          - m        e - -                      m                    . ,m    .u o, ,.
j          .
i                                                                                                                            -
i i
b                                ._
 
                                                                                                                                                                    ~
j                                                                                                                              PENthR NPV-1 theakt                                                    ..
i
.i 1
i    s. nemente l                                                                                                                    .
l    s. ossie eenedene                                                2779                                                            650                  ., ,                                  1878 j                                                                    tene==e ausse=new
                                                                                                                                                                        - mens                              gu j  to, com mornho spessee                                                    4507                                            ,g a goo. ,-
: 11. Nyeeessestest                                          6775                                              pis, cem enoresids ma m                        4958                                    ,,,      ,
1 campamon oresseen                                                .
new, & es,ened by William R. Rowlett, Jr. ,,,, m                                                                                                                AR                    6436 came neport amened by                                                    Ronald S. Farrell                                                          p.g.sie,e    PA          g ,m,      35216-E l
l                                                                                                                                                          .                                  .
!                                                                                                                      camacma .norcoMamics                                                                            -
1
!. we eerser met me essesmenn made h ese report are eenes and men ese m er valve eerderme a se ndse ser eeneounden
!    et me ASME Code. Session IE. Divielen 1.                                                                                                                                                                              .
OIII12 l    N CuelRemes of Aumerienden
* Emptme    4/15/95                                        l oss,/2-to-T .:                                                              Anchor /Darlino Valve C-n3iped                                                      49      -
j ,                                                                                                                  ascarenesseNeuere                                  sauemmes reemmenesswee                          g l
1 i
j                                                                                                                  .
commcATE or anorsospumoss                                                                            -
}-                                                                                                                                                                                                                              l
: 1. me undarongned, hoheng a weed enemiselon leeued by to Madonal Beerd of Beer and prenewe Vessel inesestere and i    om stemmasemeisse e,                                                Pennsv1vania                                                              ende,,,esyed g oannercial Union Ins. Co.
!    e,                                              , Boston. Mass.                                                                                                                      ~
heve inspaned me purne, w veh, deserend h mie osis neport en
;    /0-/ zC /2.-31                                                    . to 3.3 . and emes met se me heat et my knowledes and beast. me Cnenoese Heider hae l    oeneousand mie' pump, er velve in seeerdense wie me ASME code, asedan ut. Dhdalen 1.
i l    ty siping mis serenesis, neieer the inspessor ner his employer mesmo any woneney, meressed er knpaed. eenoeming the j    esmponent deserlbed in me. Date Report
                                                                                                                                  , nehher the bisposeer ner his employer sheE, he EeMe in ,any enanner for any pereenes k$ny er preewty                                                                                          at    kind aristne from er mennessed wah tMe inspeeden.
o,,,/2-11-W                                                                                                                M            ce,,,,,d,me,.        Pennsylvania 2392
                                                                                                                          ~~
6h >^ ~                                        -- V                          8"''''"'"*'"""""'""""'''"'"'*'
i m es, re.en e.y operated
(/                                                                  .
;                                                                    es ordy.
b l
l                                                                                                                                                                                                                        .
i
* 1 i
l 1
1 '
 
__ .                        ..    .- _--                    -                  . - . - - ..                        .            .      .-        _-=        . _ ._-.
i I                                                                                                  .
JST-70 PORM NPV-1 CENTIFICATI HOLDERS' DATA REPORT POR NUCLEAR PUMPS CR VALVES'74 4 7.- 7,7y. 1 - f j
As Required by the Prowlsions of the ASME Code, Section E, Olvlalon 1 Ps.            of i        '
Anc' hor / Darling Valve Co. 701 First St.. Williamsport. PA 17701                                                        ;
i          t. u.,sdes      s e.g esname gy
                                                                                ====.nsese e w a c.en            nos.n l                                                                                                                                                                            ;
: 2. unregemenester EntetCY Operations, Inc.                            Rt. 3. Box 13?6. Russellville. AR 72801                                          ,
l                                                                      ==am.no ases w sw.n              .o n                                                                l J
: s. L seeneebiennesen Arkansas Nuclear One, South of Jct. of Hwy. 64W & 3335. Russellville. AR menn emsessee                              .
                                                                                                                                                              /2801 W9324158            nev:
c            N/A 4.. used A Sedes Ns mType                    SE            %                                                                                        .
1989 N/A                      2                              N/A k          .s. isua cene. Seeman m. ohnumn 1:
esamme                mes.msee.ms                  mas e scoesc no.:
i                                                                                                                              2" S. Pumo,m                valwe              n ,e, d hem -            2*                o,n, s.
ou                                    au
: 7. us. ort.k Boey SA38il-CF8M                              N/A                    ge,n SA564-630-110 %                      N/A sonna W                            W                          W                            M.              ,
W
-                    Cert.                      Nesi                        Seer                      Sonnet                          elsk HaMar's                      So.d                        Said                        Send                            SeNW Ms.                        Ms.                        Ms.                              Ms.
Sedel Ms.      ,
E-T724-2-1 /                          N/A                        2874                          N/A                "/C A668
( E-T724-2-3 7                                N/A                        2881                          N/A                "/C A668                      ')
E-T7 24 4 / .                      N/A                        2882                          N/A                "/C A668 E-T724-2-6 7                          N/A                        2883                          N/A                "/C A668                e E-T7 24-2-7 / ,                        N/A                        2886                          N/A                "/C A668
.-          E-T7 24-2-R V                          N/A                        2887                          N/A                "/C A668 1
i i
i
)
i 1
1 i
i              su en.n.nie w.m      a m senn of e    ansen .        ine. m.y m        e er eems ni sm. = am x it. im ww.naseen m i m. i mm.sh 4 h sh t1.nummeros ns 9.n.se.r of sh                mens et 9.t.,of IN. f nn.
;              enIN.D m A ort le mehs ss en      h sh t.13                                              q.4.p nmi                      -                  .            e      .        r              m            .      s..          .u .=1.
s I
3 e
 
l                                *i
                                                                                                                      .(                    *
                                                                                                                        ~
PORM NPV 1 theekt                                                                ..                      1 i                                                                                                                                                                                    '
1 l          s. numeras i                                                                                              -
j                                                                                                                                                                    .
l          s. Dessen eenemens              2779                    pel        650                e, , ,,see , es,se                              1878        in 3                                            tresses                        sememesse i        io,cowweresse -                          4507                  ,es ios. ,-
1 i        11. Nyeessnes ess            6775              ok, oisk anerendesmes p                                  4958                                        ,,,,
i                                                                                                                                                                        ,
t camncAttoN oraussen                                                      .
neden spessneeden omvense by William R. Rowlett. Jr. ,,,, ,                                                  AR                    6436 i                                                  Ronald S. Farrell                                                        PA nemen nepet ewoned by                                                                  P.E. same                        g ,e,      35216-E 1
I cumnCATE OF SHoPCOMpMANc3
* we eene estr me essesmenes mens h ese esport are earme and ee' een pump er vehe eensonne as me mens ser eenseruseen                                                    '
W me AsMe cess, sessen m.ousten 1.
N connesse W Ameeressenenm                    N1712                                                                    4/15/95 essene os. /2 - zo-T _ ___ Anchor /Dar11no Valve Omngi,,edN M.
                            -                                  8' C***"" ""*'8                                                huommesses    mme
{
camncATs or aHOPWapecTION                                                                                    -
: i. es mwd. hetene e vend eenwesenen lesund by em Nedenes Beeni W Sotw and pmeewe Vesed inspectere and                                                                  '
Pennsylvania en semensenwesen d                                                                ende,,,n,,ed e,Connercial Union Ins. Co.
g              , Boston. Mass.                                                                                                    ,
here insposeed om purne, or vehm, deserend in ede Does Report en
            /o-/ A /2-21                      , is 9,J , and esses met to me been of my treweedes and baser, me carensees Heider has coneousand mis pions, er vesve, h seendenes wesh the ASME Come, seeden m. OMelon 1, er anydne ele eenmoses, noemer es inspeeeer nor No empiover mebes any warreney, esamesed er imated, eenoeming me oorneenent deserted in mis osse Report.
:            any personalinewy or property
                                                                            , nehner ee insposest ner his empiover ehes,he satie h _eny enanner for
                                                    . .      .                kind arteine from er eennessed wee sie insposeen.
l            ones 12-11-93                                                                ce,,emogene                  Pennsv1vania 2392 6hgg,m' , " , , , /
                                                                  ~
l                                                                                                              ise=1. as, ens. ene====nw men er ww. =m a
,        (1) Per manuesy operoemd veeves only, i
j                              -
4                                                                                                                                                                                    l i
* 9                                                                                                          ,
I i
4 1                                                                                                                                                                                    I
:                                                                                                                                                                                    I i
 
Page 1 (Front)  l FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS                                                                                  ,
As Required By The Provisions Of The ASME Code Section XI                                                                    I l
i
: 1. Owner AP&IJEntergy Operations, Inc                                                    Date        04/05/94 Naaw Rt. 3, Box 137G, Russellville, AR 72801                                              Sheet        1                of          1
                                            .m
: 2. Plant - Arkansas Nuclear One                                                          Unit            Two Rt. 3, Box 137G, Russellville, AR 72801                                              JO# 00909000 & 00909001 Ad&us                                                            Repar Organizance P.O.No Job No mc.
: 3. WorkPerformedby AP&IJEntergy Operations,Inc                                  ~
Type Code Symbol Stamp                  N/A Nanu                                            Authorization No                        N/A Rt. 3. Box 137G, Russellville, AR 72801                                              Expriation Date                        N/A Ahas
: 4. Identification of System HPSI ( 2DCB-3 ) -
: 5. (a) Applicable Construction Code          sen                  19 89          Edition, NO                  Addenda, NA                        Code case  ;
(b) Applicable Edition of Section XI Utilized for Repairs of Replacements 19                86
: 6. Identification of Components Repairs or Replaced and Replacement Components ASME Code      3 National                                        Repaired,            Stamped Name of              Name of                Manufacturer                Board        Other              Year          Replaced,              (yes      !
Component            Manufacturer                Serial No.                  No. Identification          Built      or Replacement            or No)    -
i l    2" GLOBE              ANCHOR                  ET-724-2-8            N/A            2SI-69              1993          REPLACEMENT YES
!    VALVE                  DARLING 2" GLOBE              ANCHOR                    ET-724-2-4            N/A            2SI-71              1993          REPLACEMENT YES VALVE                DARLING N/A N/A.                                                                                  ;
L                    N                                                      "'^
: 7. Descripdon ofWork INSTALLED NEW VAINES INTO SYSTEM l    8. Tests Cou.      *d        Hydrostatic l X l Pneumatic l                l Nominal Operating Pressure l          l j                                  Other l        l Pressure      1884            Psi    Test Temp AMB                    F l
j-      NOTE: Supplemental Sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) informa-tion in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
t l . (12/82)                      This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 i
i                                                                                                                                              REPRINT 12/91        !
l
 
          -          -              -      . . _ -    -    . ~ . - .-                  -          _ .-            .      .                        .- - -              .-.
i Page 1 (Back)
FORM NIS-2 (Back)                                                                                    ,
: 9. ' Remarks NPV-1 hMNUFACTURERS DATA REPORT FOR NEW VALVES A*1TACHED Applicable Manufacture) Data Reports to be attached
                                                          - CERTIFICATE OF COMPLIANCE We cenify that the statements made in the report are correct and this                    REPLACEMENT conforms to the rules of the l
ASME Code, Section XI.                                                                        Repair or Replacement T>pe Code S>tabol Stamp                                                                        N/A l-  Certificate of Authorization No.                        N/A                      Expintion Date                                    N/A Signed                I,/ I                        o                              Date          S-E                                      ,19 %
l              Owner o/ Owner's Desiance. TV '
D.B. Lomax - Manager, Engmeenng Programs CERTIFICATE OF INSERVICE INSPECTION l
  - 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Provirice of          Arkansas                      and employed by                Factory Mutual Engineering Association                                  of Norwood. MA                                                                                                        ected the componentsdescribed in this Owners Report during the period                    10/20/92                            A%ilF haveinp#f/4f[#9/96and statetha to 7///94/ '//
to the best of my knowledge and belief, the Owner has performed examinations And taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed orimplied, concerning the
!    examinations and corrective measures described inthis Owners Report Furthermore, neither the Inspector norhis employer l    shall be liable in any manner for any personalinjury or property damage or a loss of any kind arising from cr connected with this j    inspection.
Q o . 2 /a, O                                                        Commissions                    NB-9947, Ark.1133, "N" , "I" , "A" 4                            Inspector's Signature                                                        National Board, State, Province, and Endorsements U                              - J.O. Elliott -
Date      .6"/3                                  19 M
 
/                                                                                .
PORM NPV 1 CERT 1PICATE HOLDERS' DATA REPORT POR&NUCLEAR                                                                                    E7- 7,y p_ pPUM As Required by the Pn, visions of the Asus Code, sostion C Devision 1 l                                                                                                                                          P..            oe p
i
      ~
: 1. na iwessess a w es,enes my Anchor / Darling Valve Co. 701 F1rst St.. Williaosporte PA 17701 i
                                                                                      ==nooneeseem wac.emmeneem i          2. namnweenawser Enterav Operations. Inc. . Rt.1. Box 1376. Russellville AR 72801                                                                                      ,
e== =mesmessee shmen.o non j          s. taaseenerinmesses. Arkansas Nuclear One. South of Jct. of Hwy. 64W & 3335. Russellville, AR e          seaseene                            .
12801 GB                          N93241b8            Rev:
c              M/A
: 4. nesed No, sedes No., w %                                      Osewins l
* i 1989                      N/A                        2                                  N/A i          .s.' isam case, seamen a, pues i; esamen            amassnesone                enuse      .
cesscome e4 l                    ,
2" valwe                  y,,,,,, is, m            28                o,,, ,,,
l            s. Puseore                                                                    an.1                                    au f
: 7. Reesemsk gedy SA351-CFBM                        sonna        N/A                  tus SA564-630-110 %                            w/a i
;                        W                              W                            W                            M.              ,
W cert.                        seer 1                        seer                        sonnet Disk
-                    Heider's                      seed                          send                          send                              send sanalMs.        ,                  Ms.                          sen.                          a.                                80 s.
E-T724-2-1 /                              P /A                      2874                              N/A                  "/C A660
      ' E-T724-2-3 7                                  1  /A                      2881                              N/A                  "/C A660 E-T724-2-4 / .                            > /A                        2882                            N/A                      /C A668 l
i          E-T7 24-2-6 7                              >/A                        2883                            N/A                  "/C A668                e l          E-T724-2-7 / ,                            N/A                        2886                            N/A                  "/I A668
!- -  (E-T724-2-R V                                    N/A                        2887
                                                                                                    ~
N/A          ' "/C A668                            ' _)
                                          +
                              ^
                                                                                                                                                                                              ?
J-
              'Siemenmanus keennemen in tonn of asas, smessnes. er sowings nwy se used poseems til also le 816 x 11. (a Wennseen en seeme 1 enough 4 en ins Deus Assert is inukseed en eesh sheet, la oesh shoot is nuneered and eie seeneer af shosse is reassded at Wie toe of ins femt.
112/006                    This tonn 10000371 esey to assobied foem sie Order Dest., AgedE. 22 Law Ostue. Ses 2300. Fernets. NJ 070071300.
p                                                                8 e
    -                                  -        -  r n  -          -                          .                                  , -                            - - - - , --
 
e
(                            *
                                                                                                      ~
!                                                              P0fuW NPV-1 theakt                                                            .,
I      .
4                                                                                                                                                                                t S. Remarks r                                                                                                                                                                    i
}        s. neden eenemme              2779                ,,          650              . , , ,eese - e,es                              1878        ni                        l
!                                      weseem                      amusessem                                                                                                    i 10, cow worthe messee            4507                ,g ,oo., -
!        11. Hymeasseseast            6775        ,g. ENak eNerened am p                          4958                                            ,,,    ,
i                .
i
:                                                            campicAfton cPonsam                                                      .
i o,g, % e ,ened liy Will1am R. Rowlett, Jr. P.s.sorse                                            AI                          6436
                                                                                                                          % rie.
onde w eerened try                Ronald S. Farrell                            p.g. 3,,,        PA
                                                                                                                          % 35216-E campicATEor anoPcompuance
* J We eenwy met we seismenes made h ode report am eeness and est ede mene w vesve eensonne es en russe for eensevesen er me Aenas case, sessen m oMalen 1.                                                                                  .
n c eneses W Airessemasonu.              K1712                                                espiree        4/15/96                                                  l o,,,/2-20 4 ..                    Anchor /Darlino Valve Cen.g nes                    g a c.nesse nmani -                                          seem mee:==            e                          g I
complcATE OF SHOP SIOPECMON                                                                                    .
I. es undersigned, hoheng a weed commission leeued by sw Nettenal Beere of toAer and Pressure vessel Inspectors and 4        ee stese m e,                    Pennsv1vania                              engsen,se,,g ,Connercial Union Ins. Co.
!        og            . Beston. Mass.                                    heve hesmened me pump, er veeve, deseresed h ele Date Report on i        /o-/ A /2-21 . is .9.3 . and sises est a me meet et my knowiedes and beset, en coronesse Hekser has eeneousend mie pump, w veh=. h senereense wah me Asus case, asemen m. oMmen 1.
i l        Dr sirine mis eenmesis, noseer me inspooner nor me emptever makes an'y woneney, espressed er knoEsh eenoemhe me j        esmoonent descrened in ele Oste Report.
nelmer me inesesser nor Ne employer sheE,he EeMe in ,any manner for                                        j any persond i$ry or propony                        et      the arishe from er sonneesse wee tNo inspeeman.
j;        .
i        o,./2-11 5                                                                                  Pennsylvania 2392 c,          ,.
!                                          6ha'en, n'ono /                                    3""1. es.        ene=== mm          = s==. == no.
niew mere ye ,e,s.ed          ee ordy.
                                                  //                                                                        .
i t
i                            .
1                                    .
]'
k -
t                    .
i                                                                                                                                .
i.
i
 
]                                                                                                                                              -
2SI- 7/
}
j                      PORM NPV-1 CGmRCATE HOLDERS' DATA REPORT POR NUCLEAR PUMPS CR VAL As Required by em Provisions of the AsME code, section EI, DM8 ion 1 Ps.            et 1
l        '
Anc' hor / Darling Valwe Co. 701 F1rst 5t.. Williansport. PA 17701
: i. nas,,see.,en            e          ,w
,                                                                                    ==    .e e      m a c.enam nes.,
j            z ns weeneess. Enterav Ooerations. Inc., Rt. 3. Box 1376. Russellville AR 72801 sim      .e ese m m euen,o =n                                                                  !
l
: 3. i.soseeneelneestemen Arkansas Nuclear One. South of Jct. of Hwy. 64W & 3335. Russellville, AR l 12801
                                                                                              ===e  sese.es                                    .
!                                                                                                                                                            N/A
: 4. named m.senss pen arry,e                      AR          %                W9324158              nev:
                                                                                                                                    --            y l
4 1989 N/A                            2                            N/A l          .s.' isnes case. seamen u. nevision 1:
essess                mes.a esse                      seems mes.c nu j
Valve                  ,,,,,,,,g,,,.              2"                  g ,, , ,,,,                2"
: s. Pumeervesse                                                                                                            ou
}                                                                                            au
: 7. nessense: see, SA351-cF8N                      nee,,a    N/A                  cask SA564-630-110 Q                                w/a j
j i                          W                            m                            m                                m.                '
w can.                        Best'l                        Beer                          sonnes                            Desk 1
gesed                        go,ieg ge,ggg '                        g ,ge j                        Helder's pen,                            gee, 3                        Sedel pen,  ,
see.                        see.
E-T7 24-2-1 /                              N/A                          2874                              N/A                  "/C A668 E-T724-2-3 7                                                                                            N/A                  "/C A668
                                                      > /A                        2881
                                                                                                                                                                    )
;      C E-T724-2-4 /                                  9  /A                      2882                              N/A                  "/C A668 l-T724-2-6 7                                  >/A                        2883                              N/A                  "/C A668            ~
E-T724-2-7 / ,                            N/A                        2886                              N/A                  "/I A668 E-T724-2-R V                              N/A                        2887                              N/A                  "/C A668 p-f I
l l
i                                                                                                                                                                        -
l                                                                .
4 1                                                                                                                                                                            )
1 I
l i        .
see.m.nis wenn.e.n m sean w as                n = e m n., e. e w.s m me. i 8m x it. tm ww-se n m si.=. i eveuen 4
                    .n ses One n nis msnm s en n an i. in n een is nwne e ens es nwneer w n                            is    m s . en me w een senn.
}
i j              lt2/901                    This f.nn (8000375 may h. he.bi.e h.m in. Order Dest ASMS. 22 La.s Odvs. Sea 2300. PeirAsid. NJ 07007 2300.
i i                                                                        '
1            .
i                                                                                                                                                '
I 1
I                                                                                                                    -
 
PENIM NPV-1 theekt                                                                  ..
I i
l i
: s. namens I
,'        s. Dessen eenede,.        2779                ,,            650                                                                1878 imene-se                      mesesseee
                                                                                                  . , e, ,elve , ,ses.                                    m
: 10. cow wedeia posene            4507                ,e , goo., -
: 11. Myeessedemas          6775        ,g, oi,e m ,, m                                        4958                                            ,,,    ,
CamRCA1 nom ornestem                                                          .
AR                          6436 e.g,e    m .,,ened Ianaid S. FarrellWilliam R. Rowlett, Jr. PA nemen nopen essmand by P.E. Smen                        g      35216-E CENRCATE OF SHOP 00MPU4f0CE
* we eenwy est me annamenes made in ede eepen om eenesi and met odo pump er velve eensonne se me even. #er eenseusden of the ASME Code. Reeden 15. Division 1.
N Canineses of Aushednesien h          I01712                                                    Esphs            4/15/95 com/2-20 4                      Anchor /Darline Valve C-n.nyied                                          M.
  , ,                                              a cosasses Messere                                          scenemos semes==semme g
                                                ,      CEMRCATE OF SHOP WISPECTION                                                                                          -
: 1. we widersigned, holdng a weAd enemiselen leeued by me Nedensi Seese of Serer and Frenewe Vessel inspeetere end we steismeettuisam ,,          Pennsylvania                                endem,se,,de, Commercial Union Ins. Co.
of          ,
Beston. Maas-                                  have insposeed om pump, or vesve, deserted bi ele one Report en
;        /O-/1/2-21                    10 d. and sene that to the best of eny knowledes and besef. sie Certinesse Helder hae l
4 oenseussed ehraume, er velve. In esseseense wie the ASME Code. Seemen M. Division 1.
l        er sirens ein eenineen, nenhor the insposeer ner his unpiover makee any woneney, messened er imoned, coneeming the                                                  i j        esmoonent deoermed in this osis neoert.                  . nehher me inspesser nor his empeever ehes he seus in any menner for i        eny pasones Wwy or propony _. .          .      of        und arteens trem er eennessed whh mio inspeeden, e                              *
!        osseL2-1)49          my
                                                        "                      cornmisesens              Pennsv1vania 2392 i                                        th^"^                  -- V                                ****'******'*"**********'***I L                                              (/                                                                                  .
L        m eer e.e.e.y see,eeed      e. dy.
i
:f                                                                                                  .
}                                                                                                                                    .
:                                                                                                                                                                            i b                                                                                                                                                                              l
:                                                                                                                                                                            i l
!                                                                                                                                                                            i i                                                                                                                                                                            I
 
Page 1 (Front)
FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI
: 1. Owner AP&IJEntergy Operations,Inc                                              Date      03/20/94 Name Rt. 3, Box 1370, Russellville, AR 72801                                      Sheet        1              of          1 m m.
: 2. Plant        Arkansas Nuclear One                                            Unit            Two Rt. 3, Box 137G, Russellville, AR 72801                                        JO# 00910426 Address                                                  Repaar Orgamration P.O.No. Job No sec.
: 3. Work Performed by AP&IJEntergy Operations, Inc                                Type Code symbol Stamp                N/A Name                                    Authorization No                      N/A Rt. 3. Box 137G, Russellville, AR 72801 -                                    Expriation Date                        N/A m
: 4. Identification of System HPSI (2GCB-16 )
. 5. (a) Applicable Construction Code            sc                19 69      Edition, SUPP 1 & 2 Addenda, NA                              Codecase (b) Applicable Edition of Section XI Utilized for Repairs of Replacements 19        86
: 6. Identification of Components Repairs or Replaced and Replacement Components ASME Code National                                    Repaired,            Stamped Name of                Name of              Manufacturer            Board      Other              Year        Replaced,              (yes Component            Manufacturer            Serial No.              No. Identification        Built    or Replacement          or No)
COMPONENT            BECHTEL                NA                  N/A        2GCB-16-Hil          E          REPAIRED                NO SUPPORT                                                                                            1971 N/A                                                                              '
N/A N/A
                                                                      "'^
N
: 7. Description of Work REMOVED & REINSTALLED SUPPORT TO ALLOW ISI EXAM 8.' Tests Conducted            Hydrostatic l        l Pneumatic l    l Nominal Operating Pressure l          l Other l      l Pressure 'NA            Psi    TestTemp NA                    F NOTE: Supplemental Sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
.. (12/82)                      This Form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N.Y.10017 REPRINT 12/91
 
\
I-l l                                                                                                                                                                        Page 1 (Back)-
l I
i
;                                                                              FORM NIS-2 (Back)
!                                                                                                                                                                                              l I
: 9. Remarks NA Apphcable Manufacture's Data Repons to be anached I
l I
CERTIFICATE OF COMPLIANCE We certify that the statements made in tha report are correct and th -                      REPAIR                - conforms to the rules of the ASME Code, Section XI.                                                                        Repairor Replacenh.nt Type Code Spubol Stamp                                                                          N/A-Certificate of Authorization No.                      _
                                                                    -N/A                      Expiration Date                                          N/A Signed                    If I                                                      - Date            5-E                                              ,19 M Owner o/ Owner's Desianee. TV E D.B. Lomax - Manager Engineenng Programs
: l.                                                          CERTIFICATE OF INSERVICE INSPECTION-I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressurc Vessel Inspectors and the State or Province of            Arkansas                        and employed by                Factory Mutual Engineering Association                                      - of            i
                                                                                                                                                                        ~
Norwood. MA                                                                                AJf haveinspected the componetttsdescribed in this Owncts Report during the period                      10/20/92                        to7///f( Y//fb' 9//F/fV                /              ,and statethat to the best of my knowledge and belief, the Owner has performed examinations'and taken co'rrective measures described in this
        ' Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed orimplied, concerning the examinations and corrective measures described in this Owners Report.Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a los: of any kind arising from or connected with this inspection.
M . C.      dM            9                                      Commissions                      NB-9947, Ark.-l133. "N" , "I" , "A" g                          ggp                                                                              National Board, State. Provmoe, and Endorsements Date    S/J                                        19 9Y l
 
Page 1 (Front)
FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI
: 1. Oner AP&IJEntergy Operations, Inc                                            Date      04/08/94 Name Rt. 3, Box 137G, RusselMile, AR 72801                                        Sheet        I            _
of        1 Addren
: 2. Plant      Arkansas Nuclear One                                              Unit            Two Rt. 3, Box 137G, Russellville, AR 72801                                      JO# 00911128 Address                                                    Repair Orgamzaban P.O.No. Job No.,etc.
: 3. Work Performed by AP&I1Entergy Operations, Inc                                Type Code Symbol Stamp                N/A Nan =                                    Authorization No                      N/A Rt. 3, Box 137G, RusselMlle, AR 72801                                        Expriation Date                      N/A Addrea
: 4. Identification of System BS (2HCB-15 )
: 5. (a) Applicable Construction Code      8""                  19 77      Edition, S-79                Addenda, NA                                                Code Case (b) Applicable Edition of Section XI Utilized for Repairs of Replacements 19        86
: 6. Identification of Components Repairs or Replaced and Replacement Components AShE Code National                                    Repaired,                                        Stamped Name of              Name of              Manufacturer            Board        Other              Year        Replaced,                                        (yes Component            Manufacturer            Serial No.              No. Identification        Built    or Replacement                                    or No) 1" GLOBE              TARGET                76                  N/A          2SV-5633-1          1992        REPAIRED                                          YES VALVE                ROCK
                                                                    "'^
  \                                                                N/A N/A N/A
: 7. Description of \ 3rk REMOVED & REWELDED BODY TO BONNET SEAL WELD
: 8. Tests Conducted            Hydrostatic l        l Pneumatic l    l Nominal Operating Pressure l          l Other l      l Pressure NA              Psi    Test Temp NA                    F NOTE: Supplemental Sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) informa-tion in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
(12/82)                      This Form (E00030) may be obtained from the Order Dc;4., AShE,345 E 47th St., New York, N.Y.10017 REPRINT 12/91
 
I Page 1 (Back)
FORM NIS-2 (Back) 9.: Remarks N/A Apphcable Manufacture's Data Reports to be anached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this                REPAIR'          conforms to the rules of the ASME Code, Section XI.                                                                    Repair or Replacement Type Code Symbol Stamp                                                                      N/A Certificate of Authorization No.                        N/A                  Expiration Date -                              N/A                          ,
Signed            i        h Owner at Owner's Desianee. Title      / '
6                        Date            5-Z                              ,19  9/
D.B. Lomax - Manager, Engineering Programs CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State                        l or Province of            Arkansas                      and employed by            Factory Mutual Engineering Association                          of    l Norwood. MA                                                                            aA# haveinspected the componentsdescribed                      I in this Owner's Report during the period                  10/20/92                      toVMvY/d 3-/' / W//<//M                      , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed orimplied, concerning the examinations and corrective measures described in this Owner's Report;Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personalinjury or property damage or a loss of any kind arising from or connected with this                          !
inspection.
1 9.C, [                                                          Commissions                NB-9947. Ark'.-l 133, "N" , "I" , "A" g            -
inspector's Signature
                                  -J.O. Elliott NationalBoard. State. Province,and Era ~ ;
Date _ff/3                                      19 94/
 
i i
Pnge 1 (Front) ,
4                            FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS
:                                      As Required By The Provisions Of The ASME Code Section XI
;  1. Owner AP&IJEntergy Operations, Inc                                                Date      04/08/94
!                                              Nann a      Rt. 3. Box 137G, Russellville, AR 72801                                          Sheet          1                    of        1 i                                            AMrm j ' 2. Plant      Arkansas Nuclear One                                                  Unit              Two Rt. 3, Box 137G, Russellville, AR 72801 JO# 00911129 AMress                                                              Repair Organaatmn P.O.No Job No,asc.
;  3. Work Performed by AP&I1Entergy Operations,Inc                                    Type code Symbol Stamp -                      N/A                          ;
j-                                            Nan
* Authorization No                            N/A j      Rt. 3. Box 137G, Russellville, AR 72801                                          Expriation Date                              N/A
;                                            AMrm j  4. Identification of System BS (2HCB-15 )
j  5. (a) Applicable Construction Code        smm                  19 77      Edition, S 79                      Addenda. NA                      Code case
.        (b) Applicable Edition of Section XI Utilized for Repairs of Replacements 19            86
: 6. Identification of Components Repairs or Replaced and Replacement Components d
4 ASME j                                                                          National                                            Repaired,            Stamped
;      Name of              Name of                Manufacturer              Board        Other                    Year        Replaced,            (yes
. Component            Manufacturer                Serial No.                No. Identification                  Built    or Replacement          or No) l i    1" GLOBE            TARGET                  79                    N/A            2SV-5633 2                1992        REPAIRED              YES 1    VALVE                ROCK N/A N/A
!                                                                        N/A
                                                                          "'^
i N
;  7. Description of Work REMOVED & REWELDED BODY TO BONNET SEAL WELD
: 8. Tests Conducted            Hydrostatic l        . l Pneumatic l  l Nominal Operating Pressure l                  .l
;                                  Other l      l Pressure NA                Psi    Test Temp ' NA                          F
;      NOTE: Supplemental Sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in. 9) informa-i        tion in items 1 through 6 on this report is included on each shr, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
i l (12/82)                        This Form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N.Y.10017
)                                                                                                                                                REPRINT 12/91 4
                                                      -      n                                ,    ,c-  . - -          ,-.        ,
 
i Page1(Back) i 1
i
;                                                                                  FORM NIS-2 (Back)                                                                          :
r
                                                                                                                                                                              ?
1                                                                                                                                                                              i
;        9. Remarks NA Applicable Manufacture's Data Reports to be an=M I
i 1'
l 2-CERTIFICATE OF COMPLIANCE
* I' We certify that the statements made in the report are correct' and this                  - REPAIR -          ' confonns to the rules of the
[            ASME Code, Sectica XI.                                                                        Repair or Replacement
.i
: j.          T3pe Code Symbol Stamp                                                                          N/A-l            Certificate of Authorization Na                            N/A                  Expiration Date                                    N/A
          . Signed                  fo/ d                      '
Date              :6-2                                .,19 M l'                      owne/or Owner's Dominnes. Title
:                    D.B. Lomax - Manager, Engmeenng Programs i
i I
i          .
CERTIFICATE OF INSERVICE INSPECTION j            1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State i            or Province of            Arkansas                      and employed by .              Factory Mutual Engineering Association                                of
;                Norwood MA                                                                                  AAp          haveinspected the componentsdescribed in this Owner's Report during the period                      10/20/92                        1041 V/r/ ?Y M/V/f/
7
                                                                                                                                                              , and state that +
to' the best of my knowledge and belief, the Owner has performed examinationFand taken correctite measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
7                By signing this certificate neither the Inspector nor his employer makes any warranty, expressed orimplied, concerning the
        . examinations and corrective measures described in this Owner's Report.Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage ora loss ofany kind arising from or connected with this inspection.
i'
        ! /7 k . C.        [lhb      Inspector's Signature Commissions                  NB-9947, Ark.-l 133, "N" , "I" , "A" National Board, State, Province, and Endoneenents l
I V                                J.O. Elhott
: Date      4~/3                                    19  't af i
i.
 
I Page 1 (Front)
FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI
: 1. Owner AP&I1Entergy Operations, Inc                                                Date      04/01/94 N.n.
Rt. 3, Box 137G, Russellville, AR 72801                                        Sheet          1            of          1 Ahu
: 2. Plant          Arkansas Nuclear One                                                Unit              Two Rt. 3, Box 137G, Russellville, AR 72801                                            JO# 00911460 Address                                                        Repar C. e.i F.O.No., Job No.,ste.
: 3. Work Performed by AP&IJEntergy Operations, Inc                                      Type code symbol stamp                  N/A                        !
Nana-                                        Authorization No                        N/A                        l Rt. 3 Box 137G, Russellville, AR 72801                                          Expriation Date                        N/A                        l Addra.
: 4. Identification of System LPSI (2DCB-4 )                                                                                                                i 1
SECTIII                          Edition, S-73                Addenda, NA
: 5. (a) Applicable Construction Code                                  19 71                                                                  Code Case (b) Applicable Edition of Section XI Utilized for Repairs of Replacements 19            86
: 6. Identification of Components Repairs or Replaced and Replacement Components                                                                            l l
AShE Code National                                      Repaired,          Stamped Name of              Name of              Manufacturer                Board          Other            Year          Replaced,          (yes Component            Manufacturer                Serial No.                No. Identification        Built    or Replacement        or No) 2' GATE              BORG-                  2488                    N/A          2CV-5082            1974        REPAIRED              YES VALVE                WARNER
    \
            \                                                              ""
N/A N/A
: 7. Description ofWork REMOVED & REWELDED BODY TO BONNET SEAL WELD
: 8. Tests Conducted              Hydrostatic l            l Pneumatic l  l Nominal Operating Pressure l -l Other l      l Pressure        NA          Psi ' ' Test Temp NA                    F NOTE: Supplemental Sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) Informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
(12/82)                        This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 REPRINT 12/91 I
 
    . - . . . - --                      -              ~    ._. - ..
_                    .  --.              .            . . _ - _ . _ - - ~ _                    . - -          - - . _ .      .-
4
!-                                                                                                                                                                              Page 1 (Back) i i
FORM NIS-2 (Back) i                                                                                                                                                                                                  I j            9. Remarks NA                                                                                                                                                                        ,
j-                                                                                        Apphcable Manufactur(s Data Reports to be ansched 1
i 1
3 4
CERTIFICATE OF COMPLIANCE i                              We certify that the statements made in the report are correct and th                          REPAIR-                    conforms to the rules of the
: i.                ASME Code, Section XI.                                                                            Repair or Replacement i
i                  Type Code Spnbol Stamp                                                                            .N/A
,                  Certificate of Authorization No.                                N/A                  Expiration Date                                        N/A j                  Signed                    a[d                          <
Date                $.2                                      ,19 %                      '
owner or' owners De,uance. Tale li                          D.B. Lomax - Manager, Engmeenng Programs                                                                                                                              !
4
{                                                                        CERTIFICATE OF INSERVICE INSPECTION                                                                                      .
j                  I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspecton and the State j                  or Province of            Arkansas                          and employed by              Factory Mutual Engineering Association                                      of
.                      Norwood. MA                                                                                      map ha l                  in this Owner's Repon during the period                          10/20/92                        to7h/fv Mgiyed            - ~ , thy  componentsdescribed f 'WW/99          , and state that 3                  to the best of my knowledge and belief, the Owner has performed examinations 'and tafcen ciorrective' measures described in this
:                  Owner's Report in accordance with the requirements of the ASME Code, Section XI.
!                      By signing this certificate neither the Inspector nor his employer maket any warranty, expressed orimplied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer
:                - shall be liable in any manner for any personalinjury or property damage or a loss of any kind arising from or connected with this t                  inspection.
i k . C . [./h b                                                        Commissions                ' NB-9947,' Ark.-l 133, "N" , "I" , "A" g                          inspector's Sipature J.O. Elhott National Board, State, Province, and Endorsements Date        S/3                                        19 9 4/
i w  m                            ge --
 
Page 1 (Front)
FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS                                                                      l As Required By The Provisions Of The ASME Code Section XI                                                        l
: 1. Oner AP&UEntergy Operations, Inc                                              Date      04/02/94 Name Rt. 3, Box 137G, Russellville, AR 72801                                      Sheet        1                of        1 Address
: 2. Plant        Arkansas Nuclear One                                            Unit            Two Rt. 3, Box 137G, Russellville, AR 72801                                      jo# 00911737                                                      ,
Address                                                    Repair Oiganasuon P.O.No. Job No.,etc.
: 3. Work Performed by AP&UEntergy Operations, Inc                                Type Code Symbol Stamp                N/A N=                                      Authorization No                      N/A Rt. 3. Box 137G, Russellville, AR 72801                                      Expriation Date                      N/A Address 4 Identification of System MAIN STEAM (2 EBB-1 )
: 5. (a) Applicable Construction Code      SECT HI 19 68      Edition, S-70                Addenda, SEE PG2                  Code case (b) Applicable Edition of Section XI Utilized for Repairs of Replacements 19        86
: 6. Identification of Components Repairs or Replaced and Replacement Components ASME Code National                                    Repaired,              Stamped Name of              Name of              Manufacturer            Board        Other            Year        Replaced,              (yes Component            Manufacturer              Serial No.              No. Identification        Built      or Replacement          or No)
STEAM                COMBUSTION              70502              N/A          2E-24A              1974        REPAIRED                YES GENERATOR            ENGINEERING N/A N/A N/A N/A
: 7. Description of Work REMOVED LINEAR INDICATIONS IN NOZZEL TO PIPE WELD
: 8. Tests Conducted            Hydrostatic l        l Pneumatic l    l Nominal Operating Pressure l          l Other l    l Pressure NA              Psi    TestTemp NA                      F NOTE: Supplemental Sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
i (12/32)                      This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017
                                                                                                                                                      )
REPRINT 12/91          j
 
i i                                                                                                                                                            Page 1 (Back) i I
l                                                                            FORM NIS-2 (Back)
]
f                                                                                                                                                                            I
: 9. Remarks CODE CASES USED 1337.-4,1336 & 1401 Applicable Manufacture's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and th                  REPAIR-                  conforms to the rules of the ASME Code, Section XI.                                                                            Repair or Replacement Type Code Symbol Stamp                                                                            N/A Certificate of Authorization No.                            N/A                    Expiration Date                                    N/A Signed                          [          ,
Owner or (Xvner's Desianee. TitleUT a                            Date              f . Z,                              ,19 %
D.B. Lomax - Manager Engineering Programs CERTIFICATE OF INSERVICE INSPECTION -
1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State
__ or Province of                Arkansas                    and employed by              Factory Mutual Engineering Association                          _
of Norwood. MA                                                                                      AQdt# haveinspected the componentsdescribed in this Owner's Report during the period                        10/20/92                        to#7h9 Mb.'.'/7? .7M9V , and state that to the best of my knowledge and belief, the Owner has performed examinatioits' and tallen corrective t'neasures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
Bysigning thiscertificate neitherthe Inspectornorhis employer makes any warranty, expressed orimplied,concerningthe
    -examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personalinjury or property damage or a loss of any kind arising from or connected with this inspection.
S.C.                [B            h-                                  Commissions                    NB-9947. Ark.-l 133, "N" , "1" , "A"
  . (/                                        gp                                                                National Board, State. Province, ar,d Endmarnans Date                8/.3                            19 9 */
 
i i
i                                                                    .
Page 1 (Front) l                                FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS -
l                                        As ' Required By The Provisions Of The ASME Code Section XI
.i
{ 1. Owner AP&UEntergy Operations,Inc            Name Date        04/22/94
.I        Rt. 3, Box 137G, Russellville, AR 72801                                                              Sheet        1                          of          I
;                                              Adar
: 2. Plant        Arkansas Nuclear One                                                                    Unit              Two
]
Rt. 3, Box 137G, Russellville, AR 72801                                                                JO# 00912810 l                                            Address                                                                              Repair Organizauen P.O.No., Job No.,anc.
l 3. Work Performed by AP&UEntergy Operations, Inc                                                              Type code Symbol Stamp                              N/A N=
)'                                                                                                              Authorization No                                    N/A l        Rt. 3, Box 137G Russellville, AR 72801                                                                Expriation Date                                      N/A
{                                            Address i - 4. identification of System CVCS (2HCB-9 )
i i (a) Applicable Construction Code Atsc.                                        19 69              Edition, SUPP.1 & 2 Addenda, N/A                                              Code Case l          (b) Applicable Edition of .iection XI Utilized for Repairs of Replacements 19                                86
; 6. Identification ofI':,mponents Repairs or Replaced and Replacement Components i
$-                                                                                                                                                                                      ASME I
Code National                                                          Repaired,                Stamped        l
!        Name of              Name of                  Manufacturer                            Board          Other                    Year            ' Replaced,                (yes          j j      Component            Manufacturer                  Serial No.                                No. Identificatica                Built        or Replacement              or No) 1
^
COMPONENT            BECHTEL                    N/A                        N/A                      2HCB-9 H2              E                  REPAIRED                    NO
!      SUPPORT                                                                                                                        1972
!      \                                                                            "'^
;            \                                                                        "'^
i                  N                                                                  "'^
i                        N i .7. Description of Work MODIFIED SUPPORT
  ' 8. Tests Conducted Hydrostatic -l              l Pneumatic l          l Nominal Operating Pressure l                                l.
Other l      l Pressure                  N/A            Psi          Test Temp - N/A                              F l_        NOTE: Supplemental Sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) informa-
,        tion in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is
.          recorded at the top of this form.
! (12/82)-                        This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 REPRINT 12/91 a
s
                                    .-m  v -      w      . - .      . _ , .  ,
c  - - , - . . , ,                ~-            - - , . , - , , ,                    *---
 
i 1
a                                                                                                                                                                        !
Page 1 (Back)  i i
4
?
4 i
1                                                                                                                                                                        i i-FORM NIS-2 (Back)-
I
;    9. Remarks N/A~
Applicable Manuracture's Data Reposts to be ana&ed i                                                                                                                                                                      j 4
1                                                                                                                                                                        l 1                                                                                                                                                                        l 1
l
!                                                                                                                                                                        I
: j. '
1
;                                                            CERTIFICATE OF COMPLIANCE                                                                                  !
:                    We certify that the statements made in the report are correct and this                  REPAIR              conforms to the rules of the            )
ASME Code, Section XI.                                                                      Repair or Repla==mt                                                  j 1                                                                                                                                                                        1 l
1 1
!      Type Code Symbol Stamp                                                                      N/A Certificate of Authorization No.                      N/A                        Expiration Date                                : N/A Signed                  _
[                              - Date~          7/7
                                                                                                                                              ,19 9
;                  owner or 90mes Designie.Thie      (.
j                D.B. Lomax - Manager, Engineering Programs -
2 t
CERTIFICATE OF INSERVICE INSPECTION 4      I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of            Arkansas.                  and employed by                  Factory Mutual Engineering Association                            of      j
<          Norwood. MA                                                                                AAF haveiyed the components hiFued                                i '
j      in this Owners Report during the period                  10/20/92                          to 7/dN 7/#5', ;"? MW/99 , and state that
;    : to the best of my knowledge and belief, the Owner has performed examinationis 'and taken corrective ' mea'sures described in this i
Owner's Report in accordance with the requirements of the ASME Code, Section XI.
]            By signing this certificate neither the Inspector nor his employer makes any warranty, expressed orimplied, concerning the examinations and corrective measures described in this Owners Report.Furthermore, neither the Inspector nor his employer i    ' shall be liable in any manner for any personalinjury or property damage or a loss of any kind arising from or connected with this
! .-  inspection.
        $ . O.                                                            Commissions                  NB-9947, Ark.-l 133, "N" , "1" , "A"
      /7 v
Inspector's Signature                                                    National Board, State, Provuus, and Endorsemeras j                                      J.O. Elliott l          Date M F                                        19 99
[                9 9 4
4 4
4
 
                                                        ^
Attachment to 2CAN079403 l
l l
l l                                                                                                              .
i l
l NIS-2 FORMS l
(Not Included in 2R9 ISI Outage Summary Report) l I
i l
l l
I l
l l
1 l
l
  .____-___.m__----.m_--__._._.-_______._______m-
 
Page 1 (Front)
FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI                                                                  )
: 1. Owner AP&IJEntergy Operations,Inc                                                    Date    09/15/92 Name Rt. 3, Box 137G, Russellville, AR 72801                                          Sheet          1                  of      1 Addrem
: 2. Plant        Arkansas Nuclear One                                                Unit              Two Rt. 3, Box 137G, Russellville, AR 72801                                            JO# 00865111 Address                                                          Repair Organizauon P.O.No., Job No..asc.
: 3. Work Performed by AP&I1Entergy Operations,Inc                                      Type Code Symbol Stamp                    N/A                            j Name                                          Authorization No                        N/A                            l Rt. 3, Box 137G, Russellville, AR 72801                                        Expriation Date                            N/A Addren
: 4. Identification of system RCS (TOP OF PRESSURIZER)
: 5. (a) Applicable Construction Code SECT nl                      19 68          Edition, W-70                      (ddenda, 1440'                  Code Case (b) Applicable Edition of Section XI Utilized for Repairs of Replacements 19            86
: 6. Identification of Components Repairs or Replaced and Replacement Components l                                                                                                                        '
ASME Code
!                                                                            National                              .
Repaired,            Stamped l      Name of              Name of              Manufacturer                Board        Other              Year          Replaced,            (yes Component            Manufacturer            Serial No.                  No. Identification            Built        or Replacement          or No) l 6" GLOBE              CROSBY                N55605-                N/A        2PSV-4633              1975          PART                  YES        '
VALVE                                        00 4 )01                                                                  REPLACEMENT 6" GLOBE              CROSBY                N55605-                N/A        2PSV-4634              1975          PART                  YES VALVE                                        00-0004                                                                    REPLACEhENT l
N/A x                                                              -
                                                                              ^
l
: 7. Description ofWork REPLACED NOZZLE INSERT & DISC INSERT j 8. Tests Conducted              Hydrostatic l        l Pneumatic l        l Nominal Operating Pressure l              l Other l    l Pressure NA                  Psi    TestTemp NA                        F NOTE: Supplemental Sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 1I in., (2) informa-tion in items I through 6 on this report is included on each sheet, and (3) each sheet is rambered and the number of sheets is recorded at the top of this form.
l (12/82)                        This Form (E00030) may be obtained from the Order Dept., AShm,345 E. 47th St., New York, N.Y.10017                              I I
l l                                                                                                                                        REPRINT 12/91 l
l
 
I Page 1 (Back) l l
l                                                                                                                                                                              l FORM NIS-2 (Back) i
: 9. Remarks NEW NOZZLE INSERT S/N 96193-31-0010 FOR VALVE S/N N55605 00-0001                                                                                                1 Applicat le Manuracture's Data Reports to be attached I
AND NEW DICS INSERT S/N 95542-35 0013 FOR VALVE S/N N55605-00-0004.
l l
CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this                  REPLACEMENT conforms to the rules of the j    ASME Code, Section XI.                                                                          . Repair or Replacement -
Type Code Symbol Stamp                                                                            N/A Certificate ofAuthorization No.                          N/A-                      Expiration Date                                      N/A l    Signed                A[
Owner dr Owners Desianse.Tiile - /
                                                        /J                              Date                  d$/g6
                                                                                                                                                    ,19 %
D.B. Lomax - Manager, Engineering Programs
                                                                                                                                                                              ?
CERTIFICATE OF INSERVICE INSPECTION' I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of-          Arkansas                      and employed by -                Factory Mutual Engineering Association                                  ' of Norwood, MA haveinged the components described in this Owners Report during the period                  10/20/92                              to    OThrY#T, , f 9'/NAT , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken cdrrective ' measures described in this Owners Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.Furthermore, neither the Inspector nor his employer .
shall be liable in any manner for any personalinjury or property damage or a loss of any kind arising from or connected with this inspection.
h . O , [ /A                                                        Commissions                      NB-9947, Ark.-l 133, "N" , "I" , "A" g                          Inspectors Signature J.O. Elhott National Board, State, Province, and Endorsements Date        5~/.3                                19 9 '/
 
Page 1 (Front)
FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS i                                      As Required By The Provisions Of The ASME Code Section XI
!                                                                                                                                                                  l
: l. Owner AP&I1Entergy Operations,Inc                                              Date      10/27/93 Name Rt. 3, Box 137G, Russellville, AR 72801                                        Sheet        1                of            I uem
: 2. Plant          Arkansas Nuclear One                                              Unit            Two l
Rt. 3, Box 137G, Russellville, AR 72801                                          JO # 00872533 M&ses                                                      Repair Orgamrataan P.O.No Job No stc.
  . 3. Work Performed by AP&I1Entergy Operations,Inc                                  Type Code Symbol Stamp                    N/A N=                                        Authorization No                          N/A                            1 Rt. 3. Box 137G, Russellville, AR 72801                                        Expriation Date                            N/A
* Man
: 4. Identification of System RCS (2CCA-22)                                                                                                                    !
: 5. (a) Applicable Construction Code            sum                19 71      Edition, W-72                Addenda,' NA                        Codecase (b) Applicable Edition of Section XI Utilized for Repairs of Replacements 19          86                                                                {
: 6. Identification of Components Repairs or Replaced and Replacement Components l                                                                                                                                                    ASME l                                                                                                                                                    Code l                                                                          National                                      ' Repaired,              Stamped      ;
j      Name of                Name of                  Manufacturer          Board      Other_            Year            Replaced,              (yes l'    Component            Manufacturer                Serial No.              No. Identification          Built      or Replacement            or No) 6" CHECK              ANCHOR                    IN-102            N/A          2SI-14A              1975        PART                      YES l      VALVE                DARLING                                                                                      REPLACEMENT N/A N                                                                                                                                                    i x
Nm x                                                Na                                                                                      !
: 7. Description ofWork REPLACED VALVE DISC
: 8. Tests Conducted            Hydrostatic l          l Pneumatic l  l Nominal Operating Pressure lXl Other l        l Pressure 610            Psi    Test Temp 100                  F NOTE: Supplemental Sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) informa-tion in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
(12/82)                        This Form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N.Y.10017 REPRINT 12/91
                                                                            -                              .                                  --                l
 
i Page 1 (Back)
FORM NIS-2 (Back)
: 9. Remarks REPLACED VALVE DISC WITH NEW DISC S/N4858 Apphcable Manufactwe4 Data Reports to be atta&ed CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and th          REPLACEMENT cafens to the mies of the ASME Code, Section XI.                                                                      Repair or Rei-t Type Code Symbol Stamp                                                                      N/A Certificate of Authorization No.                        N/A                    Expiration Date                                      N/A Signed                        Jf [f              '
                                                      /~)                        Date                4ff6                                        ,19 %
Owner or Outus's Desianee. Tale-                                                          /
D.B. lanax - Manager, Engmeenng Programs CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board o! Boiler and Pressure Vessel Inspectors and the State or Province of            Arkansas                  and employed by              Factory Mutual Engineering Association                                    of Norwood, MA                                                                                        haveinspected the components described la this Owners Report during the period                  10/20/92                        to    M+'dbfd/ VIfv/Fv ' ,and state that
                                                                                                    ~
to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed.orimplied, concerning the examinations and corrective measures described in this Owners Report.Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personalinjury or property damage or a loss of any kind arising from or connected with this inspection.
k, d. [ ./l'N                                                    Commissions ^'              NB-9947 Ark.-I l33, "N" , "I" ', "A" National Board, State, Province, am1 Endorsements Date        S/3                              19 9 Y
 
        .          .--      -    .-                        -    - - _ . ~ .              .          -.              .-          . _ . . . - _ - _ - . _ ~ . _
i                                                                                                                                                                                      ;
i
:                                                                                                                                                                  Page 1 (Front)
FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS
.                                      As Required By The Provisions Of The ASME Code Section XI i
!  1. Owner AP&I1Entergy Operations, Inc                                                          Date      09/14/92 i
Name                                                                                                                                    i i      Rt. 3, Box 137G, Russellville, AR 72801                                                    Sheet        1                  of              1 i                                          Address
: 2. Plant      Arkansas Nuclear One                                                          Unit            Two l
!      Rt. 3, Box 137G, Russellville, AR 72801                                                    JO# 00853735 -
Address                                                                Repaar Orgamzation P.O.No Job No.,ste.
: 3. Work Performed by AP&IJEntergy Operations, Inc                                            Type Code symbol stamp                    N/A N=                                                    Authorization No                          N/A Rt. 3. Box 137G, Russellville, AR 72801                                                  Expriation Date                            N/A
;                                          Address
: 4. Identification of System MAIN STEAM (2 EBB-8 )
: 5. (a) Applicable Construction Code        SECT III 19 71      Edition, S-72                    Addenda, 1516                            Code Case
{
1        (b) Applicable Edition of Section XI Utilized for Repairs of Replacements 19                    86 1
1
: 6. Identification of Components Repairs or Replaced and Replacement Components l.
l                                                                                                                                                                      ASME Code National                                      Repaired,                        Stamped
:      Name of              Name of                Manufacturer                        Board        Other                Year      Replaced,                        (yes 1    Component            Manufacturer              Serial No.                            No. Identification              Built    or Replacement                    or No) e i
j    10" GATE            ANCHOR                  2N 241                          N/A          2CV-1002            1974          PART                              YES j    VALVE                DARLING                                                                                                  REPLACEMENT j                                                                                    N/A
                                                                                    "'^
!          \                                                                        N/A                                                                                              f N/A i
) 7. Description ofWork REPLACED VALVE WEDGE j  8.. Tests Conducted            Hydrostatic l X l Pneumatic l                      l Nominal Operating Pressure l            l l                                Other l      l Pressure          1000                Psi      Test Temp 545                    F 2      NOTE: Supplemental Sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
}
(12/82)                      This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 j                                                                                                                                                      REPRINT 12/91 1
                                                      - - . , - - ~                                                  . , - -                    .--                    ,      n- o
 
Page 1 (Back) l FORM NIS-2 (Back)
: 9. Remarks REPLACED WEDGE WITH NEW WEDGE BEARING S/N P1233 Apple Manuracu=6 Data Rapans to in anached
_      i 1
                                                                                                                                                              .l CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this            REPLACEMEN1' conforms to the rules of the ASME Cade, Section XI.                                                                    Repair or Replacement l
l l
l Type Code Symbol Stamp                                                                      N/A                                                    ,
N/A                  Expiration Date                            N/A Cenificate of Authorization No.
Signed            ,
d                                Date            yh                          ,19
                                                                                                        /
Owner orpwner's Designee. Tit)/
D.B. Immax - Manager, Fnpa% Programs CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiles and Pressure Vessel Inspectors and the State and employed by            Factory Mu3 sal Engineering Association _                  of or Province of            Arkansas AA# haveinspected the componentsdescribed
        - Norwood. MA in this Owners Report during the period                      10/20/92                    to 7h/a/ '/,Od?' 9/tM94/ , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken coriective incasures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed orimplied, concerning the examinations and corrective measures described in this Owner's Report.Furthermore, neither the Inspector nor his employer shallbe liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with th inspection;                                                                                                                                              )
NB-9947, Ark.-l133. "N" , "I" , "A"
    .Q    C.    [/JN                inspector's Sipature Commissions National Board, State Primnos, and E.a --
J.O. Elliott Date 94                    /                        19 7 Y G V l
                                                                                                                                                            ,?
 
1 Page 1 (Front)
                          - FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI
: 1. Owner AP&UEntergy Operations,Inc                                              Date      10/17/92 Name Rt. 3, Box 137G, RusselMlle, AR 72801                                        Sheet        1              of        1 Addras
: 2. Plant        Arkansas Nuclear One                                            Unit            Two Rt. 3, Box 137G, RusselMlle, AR 72801                                          JO# 00880688 Address                                                  Repair Orgamzanon P.O.No Job No.,etc.            l
: 3. Work Performed by AP&UEntergy Operations, Inc                                TYPE Code Symbol Stamp              N/A Nane                                    Authorization No                    N/A Rt. 3, Box 137G, Russellville, AR 72801                                      Expriation Date                      N/A-                        .
Address
: 4. Identification of System HPSI ( 2CCB-12 )
: 5. (a) Applicable Construction Code        smm                  19 71      Edition, S-73                Addenda N/A                    CodeCase  ,
(b) Applicable Edition of Section XI Utilized for Repairs of Replacements 19        86
: 6. Identification of Components Repairs or Replaced and Replacement Components                                                                    i ASME Code National                                    Repaired,            Stamped Name of              Name of              Manufacturer            Board      Other              Year        Replaced,            (yes Component              Manufacturer            Serial No.              No. Identification        Built    or Replacement          or No) 2" GLOBE              TARGET                2                  N/A        2CV-5035-1          1977        PART                  YES VALVE                  ROCK                                                                                    REPLACEMENT N/A N/A N/A N/A
: 7. Description of Work REPLACED VALVE DISC
: 8. Tests Conducted            Hydrostatic l        l Pneumatic l    l Nominal Operating Pressure l          l Other l      l Pressure    N/A          Psi    Test Temp N/A                  F NOTE: Supplemental Sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in., (2) informa-tion in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is                !
recorded at the top of this form.                                                                                                            I (12/32)                      This Form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N.Y.10017 REPRINT 12/91
 
    ..                  . . - -                                -..          ~      . -            - =, .-                    . - . - .          .                    . _ . .    . ..
}
1
]                                                                                                                                                                    Page 1 (Back)
}
4
}
l;                                                                              FORM NIS-2 (Back) 2 j  9 Rernarks REPLACED VALVE DISC WITH NEW DISC S/N 6 Applicable Manufacture's Data Reports to be attached
{
l 1
3 i
}
i i
CERTIFICATE OF COMPLIANCE
:                We certify that the statements made in the report are correct and this                        REPLACEMENT conforms to the rules of the ASME Code, Section XI.                                                                                  Repair or Replacement l
i l      Type Code Symbol Stamp                                                                              ' N/A I      Certificate of Authorization No.                              N/A                  Expiration Date                                        N/A Signed                      A/ -[                  J                                Date                    6Z                                  ,19 %
Owner 4r Owner's Desianee. THis /
.                D.B. Innax - Manager, Engineering Programs                                                                                                                            -
1,
,                                                            CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State
:      or Province of                    Arkansas                    and employed by              Factory Mutual Engineering Association                                        of i
Norwood. MA                                                                                          Adar haveinspected the components described -
!      in this Owncts Report during the period                        10/20/92                            to Wrhv Mh.'-h/ +'dM99 , and state that j      to the best of my knowledge and belief, the Owner has performed examinations and (aken' corrective' measures desenhd in this j      Owners Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the
!. examinations and corrective measures described in this Owner's Report,Furthermore, neither the Inspector nor his employer i      shall be liable in any manner for any personalinjury or property damage or a loss of any kind arising from or connected with this inspection.
3
    . $.b. [ M                            inspector's Sipature Commissions                      NB-9947, Ark.-1133, "N" , "1" , "A" National Board, State Province, and Endorsemerns
: 10. Elliott Date      8/3                                        19 94 i
I 4
4
 
Page 1 (Front)
:                                  FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI
: 1. Owner AP&I/Entergy Operations,Inc                                                            Date            10/17/92                                                  j Name
                                                                                                                                                                                  )
Rt.3 Box 137G, Russellville, AR 72801                                                        Sheet            1                  of          1                        1 Abu                                                                                                                              !
: 2. Plant        Arkansas Nuclear One                                                            Unit                  Two Rt. 3, Box 137G, Russellville, AR 72801                                                        JO# 00880718 Addries                                                    .
Repair Organusum P.O.No., Job No ate.
: 3. Work Performed by AP&I1Entergy Operations,Inc                                                Type Code Symbol Stamp                          N/A Name                                            - Authorization No                                N/A-Rt. 3. Box 137G, Russellville, AR 72801                                                      Expriation Date                                N/A Ahm
: 4. Identification of System HPSI (2CCB-12 )
: 5. (a) Applicable Construction Code                sum                  19 71        Edition, S-73                          Addenda, N/A                    Code case    ;
(b) Applicable Edition of Section XI Utilized for Repairs of Replacements 19                            86                                                            l
: 6. Identification of Components Repairs or Replaced and Replacement Components l
ASME Code National                                                Repaired,            Stamped Name of                Name of                    Manufacturer                Board                Other                Year        Replaced,            (yes Component              Manufacturer                    Sedal No.                    No. Identification                    Built    or Replacement          or No) 2" GLOBE              TARGET                        6                    N/A              2CV-5055-1                  1977        PART                  YES VALVE                  ROCK                                                                                                          REPLACEMENT N/A
                                                                                    "'^
N                                                                    N/A N/A
: 7. Description ofWork REPLACED VALVE DISC
      ~ 8. Tests Conducted            Hydrostatic l              l Pneumatic l        l Nominal Operating Pressure l                      l Other l            l Pressure    N/A              Psi    TestTemp N/A                              F NOTE: Supplemental Sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) informa-tion in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is
          - recorded at the top of this form.
(12/82)                      This Form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N.Y.10017 REPRINT 12/91 l
l
 
                      . .      .-        -                                                  ~                  .                            _ - _ _ - - - _
[
!                                                                                                                                                            Page 1 (Back) 1-l i
i l
FORM NIS-2 (Back) _                                                                                  l l
1
: 9. Remarks REPLACED VALVE DISC WITH NEW DISC S/N IS                                                                                                                      !
Apphcable Manufacnues Desa Reports ia be aanded i
r 4
CERTIFICATE OF COMPLIANCE We cenify that the statements made in the report are correct and this        REPLACEMENT conforms to the rules of the ASME Code, Section XL                                                                  Repair or Replacement                                                        ,
l i
  , Type Code Spnbol Stamp                                                                    N/A Certificate ofAuthorization No.                      N/A                    Expiration Date                                  N/A l
Signed J./ [                  f                            Date -          5-2                                ,19 M Owner 9fowners Demanse. Tale l              D.B. Lomax . Maneger, Ergir 64 Programs l
CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State
;    'or Province of          Arkansas                  and employed by              Factory Mutual Engineering Association                                      of Norwood. MA                                                                                                  ed        components described l
l      in this Owners Report during the period                10/20/92                        ,,  g ts ufffJC, havpipf            K    M9(/                , and state that to the best of my knowledge and belief, the Owner has performed examination 6-i tiken corrective' measures described in this Ownefs Report in accordance with the requirements of the ASME Code, Section AI.
Bysigning thiscertificate neitherthe Inspectornorhis employer makes any warranty, expressed orimplied,concerningthe examinations and corrective measures described inthis Owner's Report.Furthermore, neither the Inspector norhis employer
    - shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this
    ; inspection.
h . O. b                                                Commissions                NB-9947, Ark.-l133, "N" , "1" , "A" g                                org                                                            Nanonal Board, State, Province, and Endonemesas Date        .5~/3                            19 9 '/
l                                                                                                                                                                          :
l-l
 
Page 1 (Front) l'                              FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI                                                                !
: 1. Owner AP&UEntergy Operations, Inc                                                Date        10/17/92 Name Rt. 3, Box 137G, Russellville, AR 72801                                          Sheet          1                    of        1 Addmm
: 2. Plant      Arkansas Nuclear One                                                  Unit            Two Rt. 3, Box 137G, Russellville, AR 72801                                            JO# 00880725                                                            ,
Address                                                        Repaar Orgamzataan P.O.No., Job No.,etc.
: 3. Work Performed by AP&UEntergy Operations,Inc                                      Type Code Symbol Stamp                    N/A N=                                          Authorization No                          N/A Rt. 3. Box 137G, Russellville, AR 72801                                          Expriation Date                            N/A Addrem                                                                                                              -
: 4. Identification of System HPSI ( 2CCB-12 )
: 5. (a) Applicable Construction Code SECTIH                      19 71      Edition, S-73                        Addenda, N/A                  Code Case (b) Applicable Edition of Section XI Utilized for Repairs of Replacements 19              86
: 6. Identification of Components Repairs or Replaced and Replacement Components l
ASME Code National                                            Repaired,          Stamped Name of                  Name of            Manufacturer            Board          Other                    Year      Replaced,          (yes Component                Manufacturer          Serial No.                No. Identification                Built    or Replacement        or No) l    2" GLOBE                  TARGET              4                  N/A            2CV-5015-1              1977          PART                YES i    VALVE                    ROCK                                                                                            REPLACEMENT A
N/A
                                                                        "'^
N                                                        N/A l  7. Description ofWork REPLACED VALVE DISC
,  8. Tests Conducted              Hydrostatic l      l Pneumatic l    l Nominal Operating Pressure l                    l L
Other l    l Pressure N/A              Psi        Test Temp N/A                        F NOTE: Supplemental Sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) informa-                        l tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is                            l recorded at the top of this form.
(12/82)                        This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 REPRINT 12/91 l
 
Page 1 (Back) l i
l l
1 FORM NIS-2 (Back) 1
: 9. Remarks REPLACED VALVE DISC WITH NEW DISC S/N 14 l
Apphcable Manufactures Data Reports to be attached
                                                                                                                                                                -    4 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this          REPLACEhENT conforms to the rules of the                          i ASME Code, Section XI.                                                                    Repair or Replacement i-Type Code Symbol Stamp                                                                    N/A Certificate ofAuthorization No.                          N/A                  Expiration Date                                  N/A
  ' Signed                8 ownerer owners o um e. Tiii.~
J
                                                        /
Date        6-Z-                                    ,19    %
c l              D.B. Lomax - Manager, Engmeermg Programs l                                                      CERTIFICATE OF INSERVICE INSPECTION                                                                        I l    I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State                              l or Province of            Arkansas                      and employed by            Factory Mutual Engineering Association                            of Norwood. MA                                                                            Agp haveped the components described l    in this Owner's Report during the period                  10/20/92                    to # 7 M W A i - ( 9 %If d f v , and state that j'  to the best of my knowledge and belief, the Owner has performed examinations 'and taken corrective'messures described in this Owner's Report in accordance with the requirements of the AShE Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed orimplied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind ari. sing from or connected with this inspection.
k '. O .    [M                                                Commissions                NB-9947, Ark.-l133, "N" , "I" , "A" l
g                            Inspectors sipature J.O. Elhott National Board, State. Province, and Endomrnents            '
L      Date      S/3                                    19 9'/
l.
(
 
Page 1 (Front)
FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS                                                                    l As Required By The Provisions Of The ASME Code Section XI                                                          !
l L owner AP&UEntergy Operations, Inc                                              Date      10/17/92 Name Rt. 3, Box 137G, Russellville, AR 72801                                      Sheet        1              of          1 A.Wem
: 2. Plant      Arkansas Nuclear One -                                            Unit            Two Rt. 3, Box 137G, Russellville, AR 72801                                        JO# 00881293 Addreas                                                    Repaar Orgamzation P.O.No Job No.,etc.
: 3. WorkPerformedby AP&UEntergy Operations, Inc                                  Type Code symbol stamp                N/A Name                                    Authorization No                      N/A Rt 3. Box 137G, Russellville, AR 72801                                      Expriation Date                      N/A                          :
Addrea
: 4. Identification of System HPSI ( 2DCB-3 )                                                                                                          ,
SECTHI                        Edition,                    Addda, N/A
: 5. (a) Applicable Construction Code                            19 71                S-73.                                              Code Case (b) Applicable Edition of Section XI Utilized for Repairs of Replacements 19        86
: 6. Identification of Components Repairs or Replaced and Replacement Components ASME      >
;                                                                                                                                              Code l                                                                        National                                    Repaired,              Stamped Name of                  Name of              Manufacturer        - Board      Other            Year        Replaced,              (yes Coraponent            Manufacturer              Serial No.            No. Identification        Built    or Replacement            or No) l 2" GLOBE              TARGET                  5                N/A          2CV-5056-2          1977      PART                    YES        ,
l    VALVE                  ROCK                                                                                    REPLACEMENT N/A N/A N/A i
                    \                                                N/A
: 7. Description ofWork REPLACED VALVE DISC l
: 8. Tests Conducted -            Hydrostatic l      l Pneumatic l  l Nominal Operating Pressure l          l l                                  Othe-r l    l Pressure N/A            Psi      Test Temp N/A                  F NOTE: Supplemental Sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) informa-tion in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is l        recorded at the top of this form.
; '(12/82)                        This Form (E00030) may be obtamed from the Order Dept., ASME, 345 E. 47th St., New York, N.Y.10017 REPRINT 12/91
 
Page1(Back)
                                                                                                                                                            .i i
FORM NIS-2 (Back) ..
: 9. Remarks REPLACED VALVE DISC WITH NEW DISC S/N 16 Applicable Manufactures Desa Reports to be enached                                            i l
i l
1 CERTIFICATE OF COMPLIANCE                                                                                i We certify that the statements made in the report are correct and this            REPLACEMENT conforms to the rules of the                      l ASME Code,Section XL                                                                      Repair or Replacement
                                                                                                                                                              )
1 Type Code Symbol Stamp                                                                    N/A                                                                l Cenificate ofAuthornation No.                        N/A                    Expiration Date '                              N/A Signed                  /,/ /              M                                  Date          5-2                                ,19 94 owner 4 owner o. man Tdie r                                                                                                                      1 D.B. Innax - Manager, Engmeenng Programs                                                                                                            i CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of          Arkansas                  and employed by                Factory Mutual Engineering Association -                          of Norwood. MA                                                                              Asp              i    ed the          nents AM in this Owners Report during the period                10/20/92                        to 7/7/#9 p?_Cg# M/E U , and state that l
                                                                                                ~
to the best of my knowledge and belief, the Owner has performed examinations and talen corrective m'casures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neitherthe Inspectornor his employer makes any warran:v,- expressed orimplied, concerning the examinations and corrective measures described inthis Owncts Report.Parthermore, taither the Inspector norhis employer shall be liable in any manner for any personalinjury or property damage or a loss of any k'nd arising from or connected with this inspection.
Q . O,      [_/b h                                          Commissions                    NB-9947, Ark.-l 13 3. "N" , "I" , "A" g                      gg                                      ,
monai aoard. swa, Provino., and Endesmosas Date      5/3                              19 W
_                                                          .}}

Latest revision as of 09:39, 16 December 2024

ISI Summary Rept for Arkansas Nuclear One,Unit 2 Outage 2R10
ML20070G861
Person / Time
Site: Arkansas Nuclear Entergy icon.png
Issue date: 07/15/1994
From:
ENTERGY OPERATIONS, INC.
To:
Shared Package
ML20070G846 List:
References
NUDOCS 9407200320
Download: ML20070G861 (248)


Text