Regulatory Guide 3.50: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
(Created page by program invented by StriderTol)
Line 1: Line 1:
{{Adams
{{Adams
| number = ML13038A424
| number = ML003739463
| issue date = 01/31/1982
| issue date = 09/30/1989
| title = Guidance on Preparing a License Application to Store Spent Fuel in an Independent Spent Fuel Storage Installation
| title = (Task CE 402-4), Standard Format and Content for a License Application to Store Spent Fuel and High-Level Radioactive Waste
| author name =  
| author name =  
| author affiliation = NRC/RES
| author affiliation = NRC/RES
Line 10: Line 10:
| license number =  
| license number =  
| contact person =  
| contact person =  
| case reference number = TASK FP 907-4
| case reference number = -nr
| document report number = RG-3.050
| document report number = RG-3.50 Rev 1
| document type = Regulatory Guide
| document type = Regulatory Guide
| page count = 8
| page count = 20
}}
}}
{{#Wiki_filter:U.S. NUCLEAR REGULATORY  
{{#Wiki_filter:U.S. NUCLEAR REGULATORY  
COMMISSION  
COMMISSION  
January 1982 0 REGULATORY  
Revision 1 9.. 0 September
GUIDE OFFICE OF NUCLEAR REGULATORY  
1989 REGULATORY  
GUIDE "OFFICE OF NUCLEAR REGULATORY  
RESEARCH REGULATORY  
RESEARCH REGULATORY  
GUIDE 3.50 (Task FP 907-4)GUIDANCE ON PREPARING
GUIDE 3.50 (Task CE 402-4) STANDARD FORMAT AND CONTENT FOR A LICENSE APPLICATION  
A LICENSE APPLICATION  
TO STORE SPENT FUEL AND HIGH-LEVEL
TO STORE SPENT FUEL IN AN INDEPENDENT
RADIOACTIVE
SPENT FUEL STORAGE INSTALLATION
WASTE USNRC REGULATORY
INTRODUCTION
GUIDES Regulatory Guides are issued to describe and make available to the pub lic methods acceptable to the NRC staff of implementing specific parts of the Commission's regulations, to delineate techniques used by the staff in evaluating specific problems or postulated accidents, or to pro vide guidance to applicants.
Subpart B, "License Application, Form, and Contents," of 10 CFR Part 72, "Licensing Requirements for the Storage of Spent Fuel in an Independent Spent Fuel Storage Installation," specifies the information to be covered in an application for a license to store spent fuel in an independent spent fuel storage installation (ISFSI).However, Part 72 does not specify the format to be followed in the license application.


This regulatory guide suggests a format acceptable to the NRC staff for submitting the information specified in Part 72 for a license application to store spent fuel in an ISFSI.Other regulations applicable to the licensing of spent fuel storage in an ISFSI are in the following parts of Title 10,"Energy," of the Code of Federal Regulations:
Regulatory Guides are not substitutes for regulations, and compliance with them is not required.
2 -Rules of Practice for Domestic Licensing Proceedings
 
8 -Interpretations
Methods and solutions different from those set out in the guides will be acceptable if they provide a basis for the findings requisite to the issuance or continu ance of a permit or license by the Commission.
9 -Public Records 11 -Criteria and Procedures for Determining Eligibility for Access to or Control over Special Nuclear Material 19 -Notices, Instructions and Reports to Workers;Inspections.
 
This guide was issued after consideration of comments received from the public. Comments and suggestions for improvements in these guides are encouraged at all times, and guides will be revised, as ap propriate, to accommodate comments and to reflect new information or experience.
 
Written comments may be submitted to the Regulatory Publications Branch, DFIPS, ARM, U.S. Nuclear Regulatory Commission, Washing ton, DO 20555.The guides are issued in the following ten broad divisions:
1. Power Reactors 6. Products 2. Research and Test Reactors
 
===7. Transportation ===
3. Fuels and Materials Facilities
8. Occupational Health 4. Environmental and Siting 9. Antitrust and Financial Review 5. Materials and Plant Protection
10. General Copies of issued guides may be purchased from the Government Printing Office at the current GPO price. Information on current GPO prices may be obtained by contacting the Superintendent of Documents, U.S.  Government Printing Office, Post Office Box 37082, Washington, DC 20013-7082, telephone
(202)275-2060
or (202)275-2171.


20 -Standards for Protection against Radiation
Issued guides may also be purchased from the National Technical Infor mation Service on a standing order basis. Details on this service may be obtained by writing NTIS, 6285 Port Royal Road, Springfield, VA 22161.
-21 -Reporting of Defects and Noncompliance
25 -Access Authorization for Licensee Personnel 51 -Licensing and Regulatory Policy and Procedures for Environmental Protection
73 -Physical Protection of Plants and Materials 75 -Safeguards on Nuclear Material-Implementation of US/IAEA Agreement 95 -Security Facility Approval and Safeguarding of National Security Information and Restricted Data 150 -Exemptions and Continued Regulatory Authority in Agreement States and in Offshore Waters under Section 274 170 -Fees for Facilities and Materials Licenses and other Regulatory Services under the Atomic Energy Act of 1954, as Amended.Part 72 provides for a single licensing procedure.


The smooth functioning of this one-step licensing procedure requires that the license application be essentially complete in its initial submission.
TABLE OF CONTENTS Introduction
.....................................
Chapter 1.Chapter Chapter Chapter Chapter Chapter Chapter Chapter Chapter Chapter Chapter Chapter 2.  3.  4.  5.  6.  7.  8.  9.  10.  11.  12.GENERAL AND-FINANCIAL
INFORMATION
....................... 
TECHNICAL
QUALIFICATIONS
................................. 
TECHNICAL
INFORMATION
-- SAFETY ANALYSIS REPORT .......... 
CONFORMITY
TO GENERAL DESIGN CRITERIA .................... 
OPERATING
PROCEDURES
-- ADMINISTRATIVE
AND MANAGEMENT
CONTROLS ..................
........................... 
QUALITY ASSURANCE
PROGRAM ................................ 
OPERATOR TRAINING ........................................ 
INVENTORY
AND RECORDS REQUIREMENTS
....................... 
PHYSICAL PROTECTION
...................................... 
DECOMMISSIONING
PLAN ..........................
.......... 
EMERGENCY
PLAN ........................................... 
ENVIRONMENTAL
REPORT .....................................
Chapter 13. PROPOSED LICENSE CONDITIONS
.............................. 
Value/Impact Statement
...............................
.... ..........
Page 3.50-v 3.50-1 3.50-2 3.50-3 3.50-4 3.50-5 3.50-6 3.50-7 3.50-8 3.50-9 3.50-10 3,.50-11 3.50-12 3. 50-13 3.50-14 iii INTRODUCTION
Subpart B, "License Application, Form, and Contents," of 10 CFR Part 72, "Licensing Requirements for the Independent Storage of Spent Nuclear Fuel and High-Level Radioactive Waste," specifies the information to be covered in an application for a license to store spent fuel in an independent spent fuel storage installation (ISFSI) or to store spent fuel and high-level radioactive waste in a monitored retrievable storage facility (MRS). However, Part 72 does not specify the format to be followed in the license application.


A license under this part will be issued before the start of construction of any physical facilities involved.
This regulatory guide suggests a format acceptable to the NRC staff for submitting the information specified in Part 72 for a license application to store spent fuel in an ISFSI or to store spent fuel and high-level radioactive waste in an MRS.  The need for this revision of Regulatory Guide 3.50 arose from changes made to 10 CFR Part 72. The final rule was published on August 19, 1988 (53 FR 21651) and became effective September
19, 1988.  Part 72 provides for a single-step licensing procedure.


Under this procedure, the final design details of those ISFSI components, systems, and structures that are important to safety must be available for review and evaluation.
The smooth func tioning of this one-step licensing procedure requires that the license applica tion be essentially complete when it is initially submitted.


Part 72 also requires that a site evaluation be provided to ensure that the natural characteristics of the site and its environs are sufficiently known and have been factored into the engineering design of the installation.
Thus, the final design details of those ISFSI or MRS components, systems, and structures that are important to safety should be made available for review and evaluation with submittal of the license application.


The document in which this information is presented is a Safety Analysis Report (SAR).Although an applicant may plan to contract with another organization for the design, construction, and possibly the operation of the proposed ISFSI, a licensee under Part 72 cannot delegate to a contractor the responsibility for meeting all applicable regulatory requirements.
Part 72 also requires that a site evalu ation be provided to ensure that the natural characteristics of the site and its environs are sufficiently known and have been factored into the engineering design of the installation.


This means that the applicant must make a commitment that, as the licensee, it will have an adequate staff to ensure that regulatory requirements are met at each stage of the proposed project. If the applicant plans to contract with another organization for the operation of the proposed ISFSI, the contractual arrangements must be described in the license application.
The document in which this information is presented is a safety analysis report (SAR).  Although an applicant may plan to contract with another organization for the design, construction, and possibly the operation of the proposed ISFSI or MRS, a licensee under Part 72 cannot delegate to a contractor the responsibility for meeting applicable regulatory requirements.


Any subsequent changes in such contractual arrangements may require an amendment to the license.This guide represents a standard format that is acceptable to the NRC staff for the license application.
This means that the applicant must make a commitment that, as the licensee, it will have an adequate staff to ensure that regulatory requirements are met at each stage of the proposed project. If the applicant plans to contract with another organization for the operation of the proposed ISFSI or MRS, the contractual arrangements must be described in the license application.


Conformance with this guide, however, is not mandatory.
Any subsequent changes in such contrac tual arrangements may require an amendment to the application.


License applica-tions with different formats will be acceptable to the staff if they provide an adequate basis for the findings required for the issuance of a license. However, because it may be USNRC REGULATORY
This regulatory guide represents a standard format that is acceptable to the NRC staff for the license application.
GUIDES Regulatory Guides are Issued to describe and make available to the public methods acceptable to the NRC staff of Implementing specific parts -of the Commission's regulations, to delineate tech-niques used by the staff in evaluating specific problems or postu-lated accidents, or to provide guidance to applicants.


Regulatory Guides are not substitutes for regulations, and compliance with them is not required.
Conformance with this guide, how ever, is not mandatory.


Methods and solutions different from those set out in the guides will be acceptable If they provide a basis for the findings requisite to the issuance or continuance of a permit or license by the Commission.
License applications with different formats will be acceptable to the NRC staff if they provide an adequate basis for the findings required for the issuance of a license. However, because it may be more difficult to locate needed information, the staff review time may be longer, and there is a greater likelihood that the staff may regard the license appli cation as incomplete.


This guide was Issued after consideration of comments received from the Public. Comments and suggestions for improvements In these guides are encouraged at all times, and guides will be revised, as appropriate, to accommodate comments and to reflect new informa-tion or experience.
3.50-v As experience is gained in the licensing of spent fuel and high-level radioactive waste storage, the Commission's requirements for information needed in its review of applications for licenses to store radioactive material in an ISFSI or MRS may change. Revisions of the Commission's needs for information in connection with such licensing actions will be conveyed to the industry and the public by (1) amendments to NRC regulations, (2) revisions to this regula tory guide, (3) issuance of new or revised regulatory guides, and (4) direct communications, as needed, with the applicant by the NRC staff.  Prospective applicants are encouraged to meet with representatives of the Fuel Cycle Safety Branch, Division of Industrial and Medical Nuclear Safety, Office of Nuclear Material Safety and Safeguards, during the development of a license application to resolve any problems that may arise. An early resolution of potential problems is beneficial to all concerned with the licensing process.


Comments should be sent to the Secretary of the Commission, U.S. Nuclear Regulatory Commission, Washington, D.C. 20555, Attention:
Any information collection activities mentioned in this regulatory guide are contained as requirements in 10 CFR Part 72, which provides the regulatory basis for this guide. The information collection requirements in 10 CFR Part 72 have been cleared under OMB Clearance No. 3150-0132.
Docketing and Service Branch.The guides are issued in the following ten broad divisions:
1. Power Reactors 6. Products 2. Research and Test Reactors


===7. Transportation===
Contents of the License Application The license application is the basic document that must address each of the requirements of Part 72 and must be complete in itself. The following should be submitted as separate documents as enclosures to the license application.
3. Fuels and Materials Facilities
8. Occupational Health 4. Environmental and Siting 9. Antitrust and Financial Review 5. Materials and Plant Protection
10. General Copies of issued guides may be purchased at the current Government Printing Office price. A subscription service for future guides in spe-cific divisions is available through the Government Printing Office.Information on the subscription service and current GPO prices may be obtained by writing the U.S. Nuclear Regulatory Commission, Washington, D.C. 20555, Attention:
Publications Sales Manager.


more difficult to locate needed information, the staff review time may be longer, and there is a greater likelihood that the staff may regard the license application as incomplete.
The contents of each should be briefly summarized in the license application.


As experience is gained in the licensing of spent fuel storage, the Commission's requirements for information needed in its review of applications for licenses to store spent fuel in an ISFSI may change. Revisions of the Commis-sion's needs for information in connection with such licensing actions will be conveyed to the industry and the public by (1) amendments to NRC regulations, (2) revisions to this regulatory guide, (3) issuance of new or revised regulatory guides, and (4) direct communications, as needed, with an applicant by the NRC staff.Since the preparation of a license application pursuant to Part 72 will be a new experience, prospective applicants are encouraged to meet with representatives of the Division of Fuel Cycle and. Material Safety of the Office of Nuclear Material Safety and Safeguards during the development of a license application to resolve any problems that may arise.An early resolution of potential problems is beneficial to all concerned with the licensing process.Contents of the License Application The license application is the basic document that must address each of the requirements of Part 72 and must be complete in itself. However, the following subjects should be covered in separate reports that are identified as enclosures to the license application, and the contents of each report should be summarized in a brief statement in the license application:
1. Safety Analysis Report 2. Decommissioning Plan 3. Emergency Plan 4. Environmental Report 5. Quality Assurance Program 6. Physical Security Plan (including guard training)
1. Safety Analysis Report 2. Decommissioning Plan 3. Emergency Plan 4. Environmental Report 5. Quality Assurance Program 6. Physical Security Plan 7. Safeguards Contingency Plan 8. Personnel Training Program 9. Proposed License Conditions, including Technical Specifications
7. Safeguards Contingency Plan 8. Personnel Training Program 9. Proposed License Conditions, including Technical Specifications  
10. Design for Physical Security Format and Style The applicant should strive for clear, concise presentation of the information provided in the application.
10. Design for Physical Security Format and Style The applicant should strive for clear, concise presentation of the information provided in the application.


The applica-tion should be written in plain English and should be understandable to an educated lay person.Abbreviations should be consistent throughout the license application and its enclosures.
Abbreviations should be consistent throughout the license application and its enclosures.


Any abbreviations, symbols, or special terms unique to the proposed activity or not in general use should be defined when they first appear.A title page identifying key individuals responsible for the preparation of the license application and the oath required under paragraph  
Any abbreviations, symbols, or special terms unique to the proposed activity or not in general use should be defined when they first appear. A title page identifying key individuals responsible for the preparation of the license application and the oath or affirmation as required by paragraph  
72.11(b) should be included.
72.16(b) should be included.


A table of contents should also be included.Physical Specifications
A table of contents should also be included.3. 50-vi Physical Specifications  
1. Paper size: 8h x I Iinches 2. Paper stock and ink: Suitable quality in substance, paper color, and ink density for handling and reproduction by microfilming or image-cbpying equipment.
1. Paper size: 8A x 11 inches 2. Paper stock and ink. Suitable quality in substance, paper color, and ink density for handling and reproduction by microfilming or image-copying equipment.


3. Paper margins: A margin of no less than 1 inch should be maintained on the top, bottom, and binding side of all pages.4. Printing: a. Composition:  
3. Paper margins. A margin of no less than 1 inch should be maintained on the top, bottom, and binding side of all pages. 4. Printing a. Composition:  
Text should be single or 11/2 spaced.b. Type face and style: Suitable for microfilming or image-copying equipment.
Text should be single or 11/2 spaced. b. Type face and style: Suitable for microfilming or image-copying equipment.


c. Reproduction:  
c. Reproduction:  
Either mechanical or photographic.
Either mechanical or photographic.


Text should be printed on both sides of the paper with the image printed head to head.5. Binding: Pages. should be punched for a standard 3-hole loose-leaf binder.6. Chapter and page numbering:
Text should be printed on both sides of the paper with the image printed head to head. 5. Binding. Pages should be punched for a standard 3-hole loose-leaf binder. 6. Chapter and page numbering.
Each requirement of the regulation addressed should be shown as a separate chapter with the same number as the chapter given in this guide, e.g., Chapter 8, "Operator Training." Pages should be numbered sequentially in each chapter, e.g., 8-1, 8-2, etc.Do not number the entire document sequentially.
 
Each requirement of the regulation addressed should be shown as a separate chapter with the same number as the chapter given in this guide, e.g., Chapter 7, "Operator Training." Pages should be numbered sequentially in each chapter, e.g., 7-1, 7-2, etc. Do not number the entire document sequentially.


Procedures for Updating or Revising Pages All pages submitted to update, revise, or add to the license application should. show the date of change and a change or amendment number. The changed or revised portion of each page should be highlighted by a "change indicator" mark consisting of a bold vertical line drawn in the margin opposite the binding side.Referenced Materials Caution should be used in references to information previously filed with the AEC or NRC. Such references must be pertinent to the subject discussed, must contain current information, and must be readily obtainable or extractable from the referenced documents.
Procedures for Updating or Revising Pages All pages submitted to update, revise, or add to the license application should show the date of change and a change or amendment number. The changed or revised portion of each page should be highlighted by a "change indicator" mark consisting of a bold vertical line drawn in the margin opposite the binding side. Referenced Materials Caution should be used in references to information previously filed with the NRC. Such references must be pertinent to the subject discussed, must con tain current information, and must be readily obtainable or extractable from the referenced documents.


It may be more efficient in some cases to repeat in a license application previously furnished information.
It may be more efficient in some cases to repeat, or at least summarize, information furnished in the previously submitted document.3.50-vii
1. GENERAL AND FINANCIAL
INFORMATION
The license application should address the requirements of § 72.22, "Con tents of Application:
General and Financial Information," of 10 CFR Part 72 regarding details on the identity of an applicant.


Chapter 1. GENERAL AND FINANCIAL
If the applicant is other than the owner and planned operator of the proposed independent spent fuel storage installation (ISFSI) or monitored retrievable storage facility (MRS), details of the working and contractual arrangements between all parties involved should be set forth. Any information on such matters considered as proprietary information by the applicant should be identified and submitted under separate cover. The procedures in paragraph
INFORMATION
2.790(b) of 10 CFR Part 2 should be followed for such information.
The license application should address the requirements of § 72.14 of 10 CFR Part 72 regarding details on the identity of an applicant.


If the applicant is other than the owner or planned operator of the proposed ISFSI, details of the working and contractual arrangements between all parties involved should be set forth. Any information on such matters considered as proprietary information by the applicant should be identified and submitted under separate 3.50-2 cover. The procedures in 10 CFR 2.790(b) should be followed.If the proposed ISFSI is to be built on the site of another licensed activity or facility such as a nuclear power plant, details of the working arrangements and responsibilities of the licensees involved should be stated. Similarly, if unlicensed activities are carried out at the proposed site, any potential interactions between the proposed ISFSI and these other site activities should be explained.
If the proposed ISFSI or MRS is to be built on the site of another licensed activity or facility such as a nuclear power plant, details of the working ar rangements and responsibilities of the licensees involved should be stated. Similarly, if unlicensed activities are carried out at the proposed site, any potential interactions between the proposed ISFSI or MRS and these other site activities should be explained.


Paragraph  
Paragraph  
72.14(e) specifically addresses the required financial information that must be submitted with the application.
72.22(e) specifically addresses the required financial informa tion that must be submitted with the application.


If the applicant is a government agency or a regulated utility, the assumption is made that the applicant is financially qualified for a license under Part 72. If the applicant is a corporation organized for the specific purpose of owning and operating the proposed ISFSI, details of its organizational structure, including the responsibilities of its members to meet the financial requirements of the proposed ISFSI throughout its proposed operating life and ultimate decommissioning, must be stated. This requirement is applicable even if the proposed ISFSI is to be owned and operated by a consortium of utilities.
If the applicant is a corpor ation organized for the specific purpose of owning and operating the proposed ISFSI, details of its organizational structure, including the responsibilities of its members to meet the financial requirements of the proposed ISFSI through out its proposed operating life and ultimate decommissioning, must be stated. This requirement is applicable even if the proposed ISFSI is to be owned and operated by a consortium of utilities.


Chapter
3.50-1


===2. TECHNICAL ===
===2. TECHNICAL ===
QUALIFICATIONS
QUALIFICATIONS
Paragraph  
Paragraph  
72.31 (a)(4) and § 72.17 require a finding by the staff that the applicant is qualified by training and experience to construct and operate an ISFSI.Although spent fuel storage in an ISFSI is generally considered a relatively low-risk operation compared to some other types of nuclear activities, the design, construc-tion, and operation of an ISFSI require certain skills and an understanding of the requirements involved to ensure that the objective of a relatively low-risk operation is achieved in practice.
72.40(a)(4)  
requires a finding by the NRC that the applicant is qualified by training and experience to operate an ISFSI or MRS. Section 72.28, "Contents of Application:
Applicant's Technical Qualifications," sets forth information that must be included in the application for this purpose.
 
Although spent fuel storage in an ISFSI or spent fuel and high-level radioactive waste storage in an MRS is generally considered a relatively low risk operation compared to some other types of nuclear activities, the design, construction, and operation of an ISFSI or MRS require certain skills and an understanding of the requirements involved to ensure that the objective of a relatively low-risk operatiQn is achieved in practice.
 
The license application should contain a commitment that the applicant will staff the project with an adequate cadre of personnel possessing the required skills throughout all phases of the project.


The license application should contain a commit-ment that the applicant will staff the project with an adequate cadre of personnel possessing the required skills throughout all phases of the project. This element of the license. application is in addition to the discussion of the conduct of operations covered in Chapter 9 of the SAR.The licensee is responsible for the execution of the proposed project as described in the license application.
The licensee is responsible for the execution of the proposed project as described in the license application.


This means that, even though much of the actual work involved during the site selection, design, procurement, con-struction, and even the operating phases of the project may be performed by a contractor, the licensee must have a staff that is knowledgeable in all aspects of the project. If such a staff does not actually exist, the applicant should describe the staffing plans in sufficient detail to support the finding required by paragraph  
This means that, even though much of the actual work involved during the site selection, design, procurement, construc tion, and even the operating phases of the project may be performed by a con tractor, the licensee must have a staff that is knowledgeable in all aspects of the project. If such a staff does not actually exist, the applicant should describe the staffing plans in sufficient detail to support the finding required by paragraph  
72.3 l(a)(4).Chapter
72.40(a)(4).
3.50-2


===3. TECHNICAL ===
===3. TECHNICAL ===
INFORMATION;
INFORMATION  
SAFETY ANALYSIS REPORT As required by § 72.15, the technical information is presented in the SAR, which should be submitted as an enclosure to the license application.
-- SAFETY ANALYSIS REPORT As required by § 72.24, "Contents of Application:
Technical Information," the technical information is presented in the safety analysis report (SAR), which should be submitted as an enclosure to the license application.


A summary statement identifying the type of installation proposed (e.g., a water basin), its design capacity, any unique features incorporated in its design, and its mode of operation is adequate for the license application document.The SAR required for an ISFSI differs from the SARs for some other nuclear facilities in that the initial SAR is expected *to be complete and comparable in scope and detail to the final. SAR for facilities licensed under 10 CFR Part 50. Section 72.15 identifies the minimum information that is required to be included in the SAR. Although§ 72.50 provides for the subsequent updating of the SAR, such changes during the design and construction phases of the project are expected to be of minor importance.
A summary statement identifying the type of installation proposed (e.g., a water-basin ISFSI, a storage-cask MRS), its design capacity, any unique features incorpor ated in its design, and its mode of operation is adequate for the license ap plication document.


Any of these changes deemed significant by the staff may cause delay in the granting of the final clearance to receive spent fuel.Guidance on the preparation of the SAR for an ISFSI of the conventional water-basin type is contained in Regulatory Guide 3.44, "Standard Format and Content for the Safety Analysis Report for an Independent Spent Fuel Storage Installation (Water-Basin Type)." For the dry storage ISFSI, guidance on the preparation of the SAR is contained in Regulatory Guide 3.48, "Standard Format and Content for the Safety Analysis Report for an Independent Spent Fuel Storage Installation (Dry Storage)." Chapter
The SAR required for an ISFSI or MRS differs from the SARs for some other nuclear facilities in that the initial SAR is expected to be complete and com parable in scope and detail to the final SAR for facilities licensed under 10 CFR Part 50. Section 72.24 identifies the minimum information that is required to be included in the SAR. Although § 72.70 provides for the subsequent updat ing of the SAR, such changes during the design and construction phases of the project are expected to be of minor importance.
 
Any of these changes deemed significant by the NRC staff may cause delay in the granting of the final clear ance to receive spent fuel or high-level radioactive waste. Guidance on the preparation of the SAR for an ISFSI of the water-basin type is contained in Regulatory Guide 3.44, "Standard Format and Content for the Safety Analysis Report for an Independent Spent Fuel Storage Installation (Water-Basin Type)." For the dry storage ISFSI that is not colocated at another nuclear facility site or for a dry storage MRS, guidance on the preparation of the SAR is being developed in the proposed Revision 1 to Regulatory Guide 3.48, "Standard Format and Content for the Safety Analysis Report for an Independent Spent Fuel Storage Installation or Monitored Retrievable Storage Installation (Dry Storage)." Guidance for preparing the SAR for the use of dry storage casks at the site of another nuclear facility is contained in Regulatory Guide 3.62, "Standard Format and Content for the Safety Analysis Report for Onsite Storage of Spent Fuel Storage Casks." 3.50-3


===4. CONFORMITY ===
===4. CONFORMITY ===
TO GENERAL DESIGN CRITERIA Subpart F of 10 CFR Part 72 contains the general design criteria for an ISFSI. The subject of conformity to the genera- design. criteria o.i .overed in tala 11- the C A r3. II *sufficient that the license application contain a summary discussion of each criterion and reference where more detailed information on a specific subject can be found in the SAR.Chapter
TO GENERAL DESIGN CRITERIA Subpart F of 10 CFR Part 72 contains the general design criteria for an ISFSI or MRS. The subject of conformity to the general design criteria is dis cussed in detail in the SAR. It is sufficient that the license application con tain a summary discussion of each criterion and reference where more detailed information on a specific subject can be found in the SAR.3.50-4


===5. OPERATING ===
===5. OPERATING ===
PROCEDURES;
PROCEDURES  
ADMINIS-TRATIVE AND MANAGEMENT  
-- ADMINISTRATIVE
AND MANAGEMENT  
CONTROLS Paragraph  
CONTROLS Paragraph  
72.31 (a)(5) requires a finding by the staff that the applicant's proposed operating procedures to protect health and to minimize danger to life or property are adequate.
72.40(a)(5), "Issuance of License," requires a finding by the staff that the applicant's proposed operating procedures to protect health and to minimize danger to life or property are adequate.


Essential to these operating procedures are the applicant's proposed administrative and management controls.
Essential to these oper ating procedures are the applicant's proposed administrative and management controls.


Guidance on this subject is available in ANSI N299-1976, "Administrative and Managerial Control for the Operation of Nuclear Fuel Reprocessing Plants."*  
Guidance on this subject is available in ANSI N299-1976, "Adminis trative and Managerial Control for the Operation of Nuclear Fuel Reprocessing Plants."*  
Although ANSI N299-1976 is designed for the much more complex operating requirements of a fuel reprocessing plant, the basic principles set forth for administrative and managerial controls are considered applicable to the operation of an ISFSI. Paragraph
Although ANSI N299-1976 is designed for the much more complex oper ating requirements of a fuel reprocessing plant, the basic principles set forth for administrative and managerial controls are considered applicable to the operation of an ISFSI or MRS. If the proposed ISFSI or MRS is to be operated by the owner, a relatively brief explanation of how ANSI N299-1976 will be followed may be adequate.
72.15(a)(8)
identifies the information that is to be included in the SAR.If the proposed ISFSI is to be operated by the owner, a relatively brief explanation of how the requirements of ANSI N299-1976 will be met may be adequate.


However, if*Copies may be obtained from the American National Standards Institute, Inc., 1430 Broadway, New York, N.Y. 10018.3.50-3 the proposed ISFSI is to be operated by a contractor, con-siderable detail will be required on the working arrangements between the parties involved.
How ever, if the proposed ISFSI or MRS is to be operated by a contractor, consider able detail may be required on the working arrangements between the parties involved.


Particular attention should be placed on the description of the administration of the Independent Review and Audit Program that is identi-fied in ANSI N299-1976.
Particular attention should be placed on the description of the administration of the Independent Review and Audit Program that is identified in ANSI N299-1976.


Chapter
*Copies may be obtained from the American National Standards Institute, Inc., 1430 Broadway, New York, NY 10018.3.50-5


===6. QUALITY ASSURANCE ===
===6. QUALITY ASSURANCE ===
PROGRAM The quality assurance program required by § 72.80 must be submitted as an enclosure to the application and is briefly discussed in Chapter I I of the SAR. It is sufficient that the license application contain a commitment that the quality assurance program described is (or will be)understood by all involved in its execution and that the program will be implemented, as applicable, for all phases of the project, including any activities important to safety that have been carried out prior to submission of the license application.
PROGRAM The quality assurance (QA) program required by Subpart G of Part 72 must be submitted as an enclosure to the application and is briefly described in Chapter 11 of the SAR. It is sufficient that the license application contain a commitment that the QA program described is (or will be) understood by all involved in its execution and that the program will be implemented, as appli cable, for all phases of the project, including any activities important to safety that have been carried out prior to submittal of the license application.


This program should cover the engineering aspects of the site investigation, facility design, procurement, shop fabrica-tion, onsite construction, preoperational testing, conduct of operations, and ultimate decommissioning.
This program should cover the engineering aspects of the site investiga tion, facility design, procurement, shop fabrication, onsite construction, preoperational testing, conduct of operations, and ultimate decommissioning.


The emphasis of this program should be on those activities and items that are identified as being important to safety. The planned quality assurance effort should be commensurate with the importance to safety of such identified activities and items.Chapter 7. OPERATOR TRAINING ISFSI operators are not required to be licensed.
The emphasis of this program should be on those activities and items that are identified as being important to safety. The planned QA effort should be com mensurate with the importance to safety of the identified activities and items. A QA program that has been approved by the NRC as meeting Appendix B to 10 CFR Part 50 or Subpart G of 10 CFR Part 72 may be applied to the spent fuel storage system.* The applicant should state the intent to implement this QA program for the ISFSI or MRS, the date on which the QA program was submitted to the NRC, the docket number, and the date of NRC approval.


However, they must have a level of qual!ifications and training in subjects and operating procedures applicable to the opera-tion of an ISF SI comparable to the requirements of 10 CFR Part 55 on spent fuel pool operation for licensed operators of a reprocessing plant or nuclear power plant. Appropriate documentation of training activities and certifications of proficiency should be included in the ISFSI records.Subpart I, "Training and Certification of ISFSI Personnel," of 10 CFR Part 72 requires that a training program be established and that the personnel training program document be included as an enclosure to the license application.
*Note that 10 CFR 72.140(d)
states "A Commission-approved quality assurance program which satisfies the applicable criteria of Appendix B to Part 50 of this chapter and which is established, maintained, and executed with regard to an ISFSI will be accepted as satisfying the requirements of paragraph (b) of this section." 3.50-6
7. OPERATOR TRAINING Subpart I, "Training and Certification of Personnel," of 10 CFR Part 72 -requires that a personnel training program be established and that the program be submitted for NRC approval.


A brief summary of the program. should be included in the application.
A brief summary of the program should be in cluded in the application.


In addition to the specific operating requirements of the planned facility, the training program should also cover the nuclear engineering principles involved in the safe handling and storage of spent fuel and the regulations, regulatory guides, and national standards applicable to ISFSI operations.
Applicants who have an approved training program in effect may modify this program to cover spent fuel storage operations.


Guidance on the content of the required training program is available from the Fuel and Spent Fuel Licensing Branch, Division of Fuel Cycle and Material Safety, Office of Nuclear Material Safety and Safeguards, U.S. Nuclear Regu-latory Commission, Washington, D.C. 20555.Chapter
A description of the proposed changes should be provided.
 
ISFSI and MRS operators are not required to be licensed.
 
However, they must have successfully completed an established training program. Appropriate documentation of training activities and certifications of proficiency should be included in the ISFSI or MRS records.
 
In addition to the specific operating requirements of the planned facil ity, the training program should include the nuclear engineering principles, NRC regulations, regulatory guides, and national standards applicable to ISFSI or MRS operations.
 
Information on the content of the required training program is available from the Fuel Cycle Safety Branch, Division of Industrial and Med ical Nuclear Safety, Office of Nuclear Material Safety and Safeguards, U.S. Nuclear Regulatory Commission, Washington, DC 20555.3.50-7


===8. INVENTORY ===
===8. INVENTORY ===
AND RECORDS REQUIREMENTS
AND RECORDS REQUIREMENTS
A description of the inventory and records system for the stored fuel should be included in the license application.
A description of the inventory and records system for the stored spent fuel and high-level radioactive waste should be included in the license application.
 
Section 72.72 identifies the inventory and record requirements for radioactive material stored at an ISFSI or MRS. The records on the identity of each fuel assembly or high-level radioactive waste container should be complete.
 
As a minimum, these records should include: 1. For Spent Fuel a. Fuel manufacturer, b. Date of manufacture, c. Reactor exposure history, d. Burnup, e. Calculated special nuclear material content, f. Inventory control number, g. Pertinent data on discharge and storage at the reactor, transfer to the ISFSI or MRS, and storage at the ISFSI or MRS, h. For consolidated spent fuel, the records should show how the fuel rods can be traced to the original fuel assembly.


Section 72.51 identifies the inventory and record require-ments for spent fuel stored at an ISFSI. Because of the uncertainty as to the ultimate disposition of spent fuel stored in an ISFSI, the records on the identity of each fuel assembly should be complete.
2. For High-Level Radioactive Waste a. Origin of waste, b. Calculations of isotope and curie content whenever they are necessary, c. Waste form, d. Thermal output, e. Inventory control number, f. Pertinent data on waste stabilization operations, transfer to the MRS, and storage at the MRS.3.50-8


As a minimum, these records should cover: a. Fuel manufacturer, b. Date of manufacture, c. Reactor exposure history, d. Burnup, e. Pertinent observations on discharge and during storage at the reactor, transfer to the ISFSI, and storage in the ISFSI.If storage of consolidated fuel rods is being considered, special requirements concerning inventory and recordkeep- ing for stored fuel pins should be described.
===9. PHYSICAL PROTECTION ===
Subpart H, "Physical Protection," of 10 CFR Part 72 requires that a physi cal security plan and guard training plan (§ 72.180), a design for physical pro tection (§ 72.182), and a safeguards contingency plan (§ 72.184) be submitted.


Chapter
Since the details of the provisions for physical protection are withheld from public disclosure, these reports should be submitted separately.


===9. PHYSICAL PROTECTION===
The license application should contain only a reference to the identity of the reports and when they were submitted.
Subpart H, "Physical Protection," of 10 CFR Part 72 requires that a physical security plan (§ 72.81), a design for physical protection
(§ 72.82), and a safeguards contingency plan (§ 72.83) be submitted.


Since the details of the provisions for physical protection are withheld from public disclosure, this subject should be covered in separate reports. The license application should contain only a reference to the identity of the reports and when they were submitted.
Specific guidance on these submittals for an MRS or an ISFSI not located on a nuclear power reactor site may be obtained from the Safeguards Licensing Branch, Office of Nuclear Material Safety and Safeguards, U.S. Nuclear Regula tory Commission, Washington, DC 20555. Reactor licensees may obtain guidance on these topics from the Reactor Safeguards Branch, Office of Nuclear Reactor Regulation, U.S. Nuclear Regulatory Commission, Washington, DC 20555.  If the applicant has a physical security plan and a safeguards contingency plan that have been approved by NRC, modifications may be made to cover spent fuel storage operations.


Interim guidance regarding the proposed design for phy-Jc seclrity and the format and content of the physical security plan can be obtained from the Director, Division of Safeguards, Office of Nuclear Material Safety and Safe-guards; U.S. Nuclear Regulatory Commission, Washington, D.C. 20555.Guidance for the safeguards contingency plan is contained in Regulatory Guide 5.55, "Standard Format and Content of Safeguards Contingency Plans for Fuel Cycle Facilities." Chapter 1
A description of, and a schedule for, changes related to the spent fuel storage installation should be provided.3.50-9
1


===0. DECOMMISSIONING ===
===0. DECOMMISSIONING ===
PLAN Section 72.18 requires the submission of a decommis-sioning plan as part of the license application.
PLAN Section 72.30, "Decommissioning Planning, Including Financing and Record keeping," requires submittal of a proposed decommissioning plan, including a proposed funding plan that contains information on how funds will be available to decommission the ISFSI or MRS. The application should contain a description of the practices and procedures for decommissioning and an explanation of how the costs of decommissioning will be financed.


A brief description of the decommissioning plan is included in Section 9.6 of the SAR. The license application need contain only a brief summary statement, enough to identify what will be involved and the basis for the estimated costs of decommissioning.
Applicants who have previously submitted proposed decommissioning plans (i.e., nuclear power reactor licensees)
may show how these plans will include the spent fuel storage installation.


However, the financial provisions for carrying out the decommissioning plan at the end of useful life of the proposed ISFSI are not necessarily addressed in the SAR and must be covered in either the license application or the decommissioning plan.Chapter 1
3.50-10
1


===1. EMERGENCY ===
===1. EMERGENCY ===
PLAN Section 72.19 requires that an emergency plan be provided as part of the license application.
PLAN The applicant should submit a plan for coping with emergencies as a sep arate document.


The plan must 3.50-4 include the information listed in Section IV, "Content of Emergency Plans," of Appendix E to 10 CFR Part 50.Chapter 1
If the ISFSI is located on the site of a nuclear power reactor, the emergency plan required by § 50.47 of 10 CFR Part 50 satisfies the require ments of § 72.32 of 10 CFR Part 72.3.50-11
1


===2. ENVIRONMENTAL ===
===2. ENVIRONMENTAL ===
REPORT Section 72.20 requires that an environmental report be provided as part of the license application.
REPORT Section 72.34 requires that an environmental report be provided as part of the license application.


Guidance on the format and content of an environmental report for an ISFSI may be found in 10 CFR Part 51, "Licensing and Regulatory Policy and Procedures for Environmental Protection." In the interests of keeping the size of this report within reasonable bounds and its structure and language keyed to the general public, it is recommended that a prospective applicant confer with the NRC staff to obtain definitive guidance on the scope and content of this report.Chapter 13. PROPOSED LICENSE CONDITIONS
Guidance on the format and content of an environ mental report for an ISFSI may be found in Subpart A of 10 CFR Part 51, "Envi ronmental Protection Regulations for Domestic Licensing and Related Regulatory Functions." In the interest of keeping the size of this report within reasonable bounds and its structure and language keyed to the general public, it is recom mended that a prospective applicant confer with the NRC staff to obtain defini tive guidance on the scope and content of this report.3.50-12
License conditions proposed by an applicant constitute a commitment by the applicant to take the actions specified therein. Because a license issued pursuant to Part 72 is issued prior to the commencement of construction, license conditions cover the entire proposed life of the ISFSI, from site selection through the subsequent phases of design, construction, operation, and ultimate decommissioning.
13. PROPOSED LICENSE CONDITIONS  
License conditions proposed by an applicant constitute a commitment by the applicant to take the actions specified therein. License conditions can be con sidered in two broad categories:
(1) administrative and management organization and controls and (2) technical specifications.


License conditions can be considered in two broad categories:
Those addressing administrative and management subjects should be included in the license application;  
(1) administrative and management organization and controls and (2) technical specifications, Those addressing administrative and management subjects should be covered in the license application;  
those ad dressing technical specifications should be described briefly in the license ap plication with appropriate references to the detailed analyses in the SAR. Care should be taken to ensure that such references are clear and explicit.
those addressing technical subjects can be covered very briefly in the license application with appropriate references to Chapter 10 of the SAR. Care should be taken to ensure that such references are clear and explicit.Proposed license conditions should address such subjects as: 1. Administrative and management organization;
proce-dures and controls, including review and approval activities;
and auditing and reporting requirements.


In particular, the subject of interfaces between the licensee and its contractors should be covered.2. Verification of design features that are important to safety. In particular, those quality assurance activities that confirm that design and construction are being carried out in accordance with plans, e.g., inspection hold points, should be covered.3. Test procedures throughout the life of the project.Such subjects as conditions applicable to site evaluation, component testing during design and construction, preopera-tional testing prior to startup, and conditions applicable to tests that may be desirable after the commencement of operations should be covered.4. Functional and operating limits of monitoring instru-ments and limiting control settings.5. Limiting conditions of operation.
Proposed license conditions should address such subjects as: 1. Administrative and management organization, procedures, controls (in cluding review and approval activities), and auditing and reporting require ments. In particular, the subject of interfaces between the licensee and its contractors should be discussed.


The functional capabilities or performance levels of equipment and systems that are important to safety should be addressed.
2. Verification of design features that are important to safety. Those quality assurance activities that confirm that design and construction are being carried out in accordance with plans, e.g., inspection hold points, should be discussed.


The subject includes setpoint limits on monitoring instruments and any controls that may need to be imposed on personnel access to any part of the installation.
In particular, identify who is responsible for performing this veri fication.


6. Surveillance requirements.
3. Test procedures.


Such items as the periodic inspection of cranes and, for water pools, water purity and evidence of corrosion should be covered.3.50-5 VALUE/IMPACT
Such subjects as conditions applicable to site eval uation, component testing during design and construction, preoperational testing prior to startup, and conditions applicable to tests that may be desirable after the commencement of operations should be discussed.
STATEMENT 1. ACTION


===3. PROCEDURAL ===
4. Functional and operating limits, monitoring instruments and limiting control settings.
APPROACH 3.1 Procedural Alternatives
1.1 Description This guide is an updating of the material in -Regulatory Guide 3.24 to correct omissions and reflect regulatory devel-opments since Regulatory Guide 3.24 was issued. Regulatory Guide 3.24 was withdrawn on February 27, 1981 (46 FR 14507).1.2 Need There is increasing interest in the nuclear community in the licensing requirements for the storage of spent fuel in an ISFSI. The guide is designed to assist prospective applicants by discussing in more detail specific requirements of Part 72 for the license application.


1.3 Value/Impact
The operating limits necessary for (a) protecting the integ rity of the spent fuel or solidified high-level radioactive waste, (b) protect ing employees against radiation exposure, and (c) preventing uncontrolled release of radioactive material should be discussed.
.1.3.1 NRC The further explanation of the content of license applica-tions covering the storage of spent fuel in an ISFSI will be helpful to the licensing staff in their contacts with potential licensees and in the review of these applications when received, particularly during the "mini-review" before docketing of such applications.


1.3.2 Other Government Agencies The Tennessee Valley Authority has expressed interest in the storage of spent fuel in an ISFSI and is now trying to determine the applicable licensing requirements.
Radiation monitoring instruments and their limiting control settings should be described.


1.3.3 Industry The further explanation of the content of license applica-tions covering the storage of spent fuel in an ISFSI is thought to be particularly useful to the utilities, which deal primarily with the NRC Office of Nuclear Reactor Regula-tion and which now will be dealing with the NRC Office of Nuclear Material Safety and Safeguards, which handles the licensing of spent fuel storage in an ISFSI and operates somewhat differently.
5. Limiting conditions of operation.


1.3.4 Public There is a need to aid the public in becoming better informed on the various aspects of the licensing of spent fuel storage in an ISFSI. The guide will contribute to meeting this need.
The functional capabilities or per formance levels of equipment and systems that are important to safety should be addressed.


===2. TECHNICAL ===
The subject includes setpoint limits on monitoring instruments and any controls that may need to be imposed on personnel access to any part of the installation.
APPROACH The guide is nontechnical in its content.The following are potential NRC procedures that may be used to disseminate the information contained in the guide:* Regulation
* Regulatory guide* Branch position paper* NUREG-series report 3.2 Value/Impact of Procedural Alternatives A regulation is not a suitable means of disseminating the explanatory type of information contained in the proposed guide. A NUREG-series report is also not a viable alternative because the proposed guide contains regulatory positions.


Only a regulatory guide or branch position paper are considered to be viable alternatives.
6. Surveillance requirements.


Branch positions are sometimes presented for guidance of this sort. However, because of the limited distribution within NRC for concurrence, branch positions should be formalized by the issuance of a. regulatory guide. In this case, no branch position has been prepared or is anticipated.
Such items as the periodic inspection of cranes and storage structures and, for water pools, water purity and evidence of corrosion should be covered.3.50-13 VALUE/IMPACT
STATEMENT A draft value/impact statement was published with the proposed Revision 1 to Regulatory Guide 3.50 (Task CE 402-4) when the draft guide was published for public comment in September
1986. No changes were necessary, so a separate value/impact statement for the final guide has not been prepared.


3.3 Decision on Procedural Approach* A regulatory guide should be prepared.
A copy of the draft value/impact statement is available for inspection and copying for a fee at the Commission's Public Document Room at 2120 L Street NW., Washington, DC, under Task CE 402-4.3.50-14 UNITED STATES NUCLEAR REGULATORY  
 
COMMISSION  
===4. STATUTORY ===
WASHINGTON, D.C. 20555 OFFICIAL BUSINESS PENALTY FOR PRIVATE USE, $300 FIRST CLASS MAIL POSTAGE & FEES PAID USNRC PERMIT No. G-67}}
CONSIDERATIONS
4.1 NRC Authority Authority for this guide is derived from the Atomic Energy Act of 1954, as amended, and the Energy Reorganiza- tion Act of 1974, as amended, and implemented through the Commission's regulations.
 
4.2 Need for NEPA Assessment The action is not a major Federal action as defined by 10 CFR 51(a)(10)
and does not require an environmental impact statement.
 
===5. RELATIONSHIP ===
TO OTHER EXISTING OR PROPOSED REGULATIONS
OR POLICIES The guide is one of a series of guides that will replace Regulatory Guide 3.24, Other guides in this series include Regulatory Guide 3.44, "Standard Format and Content for the Safety Analysis Report for an Independent Spent Fuel Storage Installation (Water-Basin Type)"; Regulatory
3.50-6 Guide 3.48, "Standard Format and Content for the Safety Analysis Report for an Independent Spent Fuel Storage Installation (Dry Storage)";
and Regulatory Guide 3.49,"Design of an Independent Spent Fuel Storage Installation (Water-Basin Type)." 6. SUMMARY AND CONCLUSIONS
The regulatory guide should be issued to meet a current need in the written development of the regulatory bases for the licensing of spent fuel storage in an ISFSI.3.50-7 UNITED STATES NUCLEAR REGULATORY  
COMMISSION
WASHINGTON, 0. C. 20555 OFFICIAL BUSINESS PENALTY FOR PRIVATE USE, $300 POSTAGE AND FEES PAID U.S. NUCLEAR REGULATORy COMMISSION
120 9550,5 5 466 1 op (IS NPC ofCm P 7-G GY SHUTTL EWD:TH A P rf3 W ASH! NG Tr-N oC 2r955}}


{{RG-Nav}}
{{RG-Nav}}

Revision as of 02:56, 21 September 2018

(Task CE 402-4), Standard Format and Content for a License Application to Store Spent Fuel and High-Level Radioactive Waste
ML003739463
Person / Time
Issue date: 09/30/1989
From:
Office of Nuclear Regulatory Research
To:
References
-nr RG-3.50 Rev 1
Download: ML003739463 (20)


U.S. NUCLEAR REGULATORY

COMMISSION

Revision 1 9.. 0 September

1989 REGULATORY

GUIDE "OFFICE OF NUCLEAR REGULATORY

RESEARCH REGULATORY

GUIDE 3.50 (Task CE 402-4) STANDARD FORMAT AND CONTENT FOR A LICENSE APPLICATION

TO STORE SPENT FUEL AND HIGH-LEVEL

RADIOACTIVE

WASTE USNRC REGULATORY

GUIDES Regulatory Guides are issued to describe and make available to the pub lic methods acceptable to the NRC staff of implementing specific parts of the Commission's regulations, to delineate techniques used by the staff in evaluating specific problems or postulated accidents, or to pro vide guidance to applicants.

Regulatory Guides are not substitutes for regulations, and compliance with them is not required.

Methods and solutions different from those set out in the guides will be acceptable if they provide a basis for the findings requisite to the issuance or continu ance of a permit or license by the Commission.

This guide was issued after consideration of comments received from the public. Comments and suggestions for improvements in these guides are encouraged at all times, and guides will be revised, as ap propriate, to accommodate comments and to reflect new information or experience.

Written comments may be submitted to the Regulatory Publications Branch, DFIPS, ARM, U.S. Nuclear Regulatory Commission, Washing ton, DO 20555.The guides are issued in the following ten broad divisions:

1. Power Reactors 6. Products 2. Research and Test Reactors

7. Transportation

3. Fuels and Materials Facilities

8. Occupational Health 4. Environmental and Siting 9. Antitrust and Financial Review 5. Materials and Plant Protection

10. General Copies of issued guides may be purchased from the Government Printing Office at the current GPO price. Information on current GPO prices may be obtained by contacting the Superintendent of Documents, U.S. Government Printing Office, Post Office Box 37082, Washington, DC 20013-7082, telephone

(202)275-2060

or (202)275-2171.

Issued guides may also be purchased from the National Technical Infor mation Service on a standing order basis. Details on this service may be obtained by writing NTIS, 6285 Port Royal Road, Springfield, VA 22161.

TABLE OF CONTENTS Introduction

.....................................

Chapter 1.Chapter Chapter Chapter Chapter Chapter Chapter Chapter Chapter Chapter Chapter Chapter 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12.GENERAL AND-FINANCIAL

INFORMATION

.......................

TECHNICAL

QUALIFICATIONS

.................................

TECHNICAL

INFORMATION

-- SAFETY ANALYSIS REPORT ..........

CONFORMITY

TO GENERAL DESIGN CRITERIA ....................

OPERATING

PROCEDURES

-- ADMINISTRATIVE

AND MANAGEMENT

CONTROLS ..................

...........................

QUALITY ASSURANCE

PROGRAM ................................

OPERATOR TRAINING ........................................

INVENTORY

AND RECORDS REQUIREMENTS

.......................

PHYSICAL PROTECTION

......................................

DECOMMISSIONING

PLAN ..........................

..........

EMERGENCY

PLAN ...........................................

ENVIRONMENTAL

REPORT .....................................

Chapter 13. PROPOSED LICENSE CONDITIONS

..............................

Value/Impact Statement

...............................

.... ..........

Page 3.50-v 3.50-1 3.50-2 3.50-3 3.50-4 3.50-5 3.50-6 3.50-7 3.50-8 3.50-9 3.50-10 3,.50-11 3.50-12 3. 50-13 3.50-14 iii INTRODUCTION

Subpart B, "License Application, Form, and Contents," of 10 CFR Part 72, "Licensing Requirements for the Independent Storage of Spent Nuclear Fuel and High-Level Radioactive Waste," specifies the information to be covered in an application for a license to store spent fuel in an independent spent fuel storage installation (ISFSI) or to store spent fuel and high-level radioactive waste in a monitored retrievable storage facility (MRS). However, Part 72 does not specify the format to be followed in the license application.

This regulatory guide suggests a format acceptable to the NRC staff for submitting the information specified in Part 72 for a license application to store spent fuel in an ISFSI or to store spent fuel and high-level radioactive waste in an MRS. The need for this revision of Regulatory Guide 3.50 arose from changes made to 10 CFR Part 72. The final rule was published on August 19, 1988 (53 FR 21651) and became effective September

19, 1988. Part 72 provides for a single-step licensing procedure.

The smooth func tioning of this one-step licensing procedure requires that the license applica tion be essentially complete when it is initially submitted.

Thus, the final design details of those ISFSI or MRS components, systems, and structures that are important to safety should be made available for review and evaluation with submittal of the license application.

Part 72 also requires that a site evalu ation be provided to ensure that the natural characteristics of the site and its environs are sufficiently known and have been factored into the engineering design of the installation.

The document in which this information is presented is a safety analysis report (SAR). Although an applicant may plan to contract with another organization for the design, construction, and possibly the operation of the proposed ISFSI or MRS, a licensee under Part 72 cannot delegate to a contractor the responsibility for meeting applicable regulatory requirements.

This means that the applicant must make a commitment that, as the licensee, it will have an adequate staff to ensure that regulatory requirements are met at each stage of the proposed project. If the applicant plans to contract with another organization for the operation of the proposed ISFSI or MRS, the contractual arrangements must be described in the license application.

Any subsequent changes in such contrac tual arrangements may require an amendment to the application.

This regulatory guide represents a standard format that is acceptable to the NRC staff for the license application.

Conformance with this guide, how ever, is not mandatory.

License applications with different formats will be acceptable to the NRC staff if they provide an adequate basis for the findings required for the issuance of a license. However, because it may be more difficult to locate needed information, the staff review time may be longer, and there is a greater likelihood that the staff may regard the license appli cation as incomplete.

3.50-v As experience is gained in the licensing of spent fuel and high-level radioactive waste storage, the Commission's requirements for information needed in its review of applications for licenses to store radioactive material in an ISFSI or MRS may change. Revisions of the Commission's needs for information in connection with such licensing actions will be conveyed to the industry and the public by (1) amendments to NRC regulations, (2) revisions to this regula tory guide, (3) issuance of new or revised regulatory guides, and (4) direct communications, as needed, with the applicant by the NRC staff. Prospective applicants are encouraged to meet with representatives of the Fuel Cycle Safety Branch, Division of Industrial and Medical Nuclear Safety, Office of Nuclear Material Safety and Safeguards, during the development of a license application to resolve any problems that may arise. An early resolution of potential problems is beneficial to all concerned with the licensing process.

Any information collection activities mentioned in this regulatory guide are contained as requirements in 10 CFR Part 72, which provides the regulatory basis for this guide. The information collection requirements in 10 CFR Part 72 have been cleared under OMB Clearance No. 3150-0132.

Contents of the License Application The license application is the basic document that must address each of the requirements of Part 72 and must be complete in itself. The following should be submitted as separate documents as enclosures to the license application.

The contents of each should be briefly summarized in the license application.

1. Safety Analysis Report 2. Decommissioning Plan 3. Emergency Plan 4. Environmental Report 5. Quality Assurance Program 6. Physical Security Plan (including guard training)

7. Safeguards Contingency Plan 8. Personnel Training Program 9. Proposed License Conditions, including Technical Specifications

10. Design for Physical Security Format and Style The applicant should strive for clear, concise presentation of the information provided in the application.

Abbreviations should be consistent throughout the license application and its enclosures.

Any abbreviations, symbols, or special terms unique to the proposed activity or not in general use should be defined when they first appear. A title page identifying key individuals responsible for the preparation of the license application and the oath or affirmation as required by paragraph

72.16(b) should be included.

A table of contents should also be included.3. 50-vi Physical Specifications

1. Paper size: 8A x 11 inches 2. Paper stock and ink. Suitable quality in substance, paper color, and ink density for handling and reproduction by microfilming or image-copying equipment.

3. Paper margins. A margin of no less than 1 inch should be maintained on the top, bottom, and binding side of all pages. 4. Printing a. Composition:

Text should be single or 11/2 spaced. b. Type face and style: Suitable for microfilming or image-copying equipment.

c. Reproduction:

Either mechanical or photographic.

Text should be printed on both sides of the paper with the image printed head to head. 5. Binding. Pages should be punched for a standard 3-hole loose-leaf binder. 6. Chapter and page numbering.

Each requirement of the regulation addressed should be shown as a separate chapter with the same number as the chapter given in this guide, e.g., Chapter 7, "Operator Training." Pages should be numbered sequentially in each chapter, e.g., 7-1, 7-2, etc. Do not number the entire document sequentially.

Procedures for Updating or Revising Pages All pages submitted to update, revise, or add to the license application should show the date of change and a change or amendment number. The changed or revised portion of each page should be highlighted by a "change indicator" mark consisting of a bold vertical line drawn in the margin opposite the binding side. Referenced Materials Caution should be used in references to information previously filed with the NRC. Such references must be pertinent to the subject discussed, must con tain current information, and must be readily obtainable or extractable from the referenced documents.

It may be more efficient in some cases to repeat, or at least summarize, information furnished in the previously submitted document.3.50-vii

1. GENERAL AND FINANCIAL

INFORMATION

The license application should address the requirements of § 72.22, "Con tents of Application:

General and Financial Information," of 10 CFR Part 72 regarding details on the identity of an applicant.

If the applicant is other than the owner and planned operator of the proposed independent spent fuel storage installation (ISFSI) or monitored retrievable storage facility (MRS), details of the working and contractual arrangements between all parties involved should be set forth. Any information on such matters considered as proprietary information by the applicant should be identified and submitted under separate cover. The procedures in paragraph

2.790(b) of 10 CFR Part 2 should be followed for such information.

If the proposed ISFSI or MRS is to be built on the site of another licensed activity or facility such as a nuclear power plant, details of the working ar rangements and responsibilities of the licensees involved should be stated. Similarly, if unlicensed activities are carried out at the proposed site, any potential interactions between the proposed ISFSI or MRS and these other site activities should be explained.

Paragraph

72.22(e) specifically addresses the required financial informa tion that must be submitted with the application.

If the applicant is a corpor ation organized for the specific purpose of owning and operating the proposed ISFSI, details of its organizational structure, including the responsibilities of its members to meet the financial requirements of the proposed ISFSI through out its proposed operating life and ultimate decommissioning, must be stated. This requirement is applicable even if the proposed ISFSI is to be owned and operated by a consortium of utilities.

3.50-1

2. TECHNICAL

QUALIFICATIONS

Paragraph

72.40(a)(4)

requires a finding by the NRC that the applicant is qualified by training and experience to operate an ISFSI or MRS. Section 72.28, "Contents of Application:

Applicant's Technical Qualifications," sets forth information that must be included in the application for this purpose.

Although spent fuel storage in an ISFSI or spent fuel and high-level radioactive waste storage in an MRS is generally considered a relatively low risk operation compared to some other types of nuclear activities, the design, construction, and operation of an ISFSI or MRS require certain skills and an understanding of the requirements involved to ensure that the objective of a relatively low-risk operatiQn is achieved in practice.

The license application should contain a commitment that the applicant will staff the project with an adequate cadre of personnel possessing the required skills throughout all phases of the project.

The licensee is responsible for the execution of the proposed project as described in the license application.

This means that, even though much of the actual work involved during the site selection, design, procurement, construc tion, and even the operating phases of the project may be performed by a con tractor, the licensee must have a staff that is knowledgeable in all aspects of the project. If such a staff does not actually exist, the applicant should describe the staffing plans in sufficient detail to support the finding required by paragraph

72.40(a)(4).

3.50-2

3. TECHNICAL

INFORMATION

-- SAFETY ANALYSIS REPORT As required by § 72.24, "Contents of Application:

Technical Information," the technical information is presented in the safety analysis report (SAR), which should be submitted as an enclosure to the license application.

A summary statement identifying the type of installation proposed (e.g., a water-basin ISFSI, a storage-cask MRS), its design capacity, any unique features incorpor ated in its design, and its mode of operation is adequate for the license ap plication document.

The SAR required for an ISFSI or MRS differs from the SARs for some other nuclear facilities in that the initial SAR is expected to be complete and com parable in scope and detail to the final SAR for facilities licensed under 10 CFR Part 50. Section 72.24 identifies the minimum information that is required to be included in the SAR. Although § 72.70 provides for the subsequent updat ing of the SAR, such changes during the design and construction phases of the project are expected to be of minor importance.

Any of these changes deemed significant by the NRC staff may cause delay in the granting of the final clear ance to receive spent fuel or high-level radioactive waste. Guidance on the preparation of the SAR for an ISFSI of the water-basin type is contained in Regulatory Guide 3.44, "Standard Format and Content for the Safety Analysis Report for an Independent Spent Fuel Storage Installation (Water-Basin Type)." For the dry storage ISFSI that is not colocated at another nuclear facility site or for a dry storage MRS, guidance on the preparation of the SAR is being developed in the proposed Revision 1 to Regulatory Guide 3.48, "Standard Format and Content for the Safety Analysis Report for an Independent Spent Fuel Storage Installation or Monitored Retrievable Storage Installation (Dry Storage)." Guidance for preparing the SAR for the use of dry storage casks at the site of another nuclear facility is contained in Regulatory Guide 3.62, "Standard Format and Content for the Safety Analysis Report for Onsite Storage of Spent Fuel Storage Casks." 3.50-3

4. CONFORMITY

TO GENERAL DESIGN CRITERIA Subpart F of 10 CFR Part 72 contains the general design criteria for an ISFSI or MRS. The subject of conformity to the general design criteria is dis cussed in detail in the SAR. It is sufficient that the license application con tain a summary discussion of each criterion and reference where more detailed information on a specific subject can be found in the SAR.3.50-4

5. OPERATING

PROCEDURES

-- ADMINISTRATIVE

AND MANAGEMENT

CONTROLS Paragraph

72.40(a)(5), "Issuance of License," requires a finding by the staff that the applicant's proposed operating procedures to protect health and to minimize danger to life or property are adequate.

Essential to these oper ating procedures are the applicant's proposed administrative and management controls.

Guidance on this subject is available in ANSI N299-1976, "Adminis trative and Managerial Control for the Operation of Nuclear Fuel Reprocessing Plants."*

Although ANSI N299-1976 is designed for the much more complex oper ating requirements of a fuel reprocessing plant, the basic principles set forth for administrative and managerial controls are considered applicable to the operation of an ISFSI or MRS. If the proposed ISFSI or MRS is to be operated by the owner, a relatively brief explanation of how ANSI N299-1976 will be followed may be adequate.

How ever, if the proposed ISFSI or MRS is to be operated by a contractor, consider able detail may be required on the working arrangements between the parties involved.

Particular attention should be placed on the description of the administration of the Independent Review and Audit Program that is identified in ANSI N299-1976.

  • Copies may be obtained from the American National Standards Institute, Inc., 1430 Broadway, New York, NY 10018.3.50-5

6. QUALITY ASSURANCE

PROGRAM The quality assurance (QA) program required by Subpart G of Part 72 must be submitted as an enclosure to the application and is briefly described in Chapter 11 of the SAR. It is sufficient that the license application contain a commitment that the QA program described is (or will be) understood by all involved in its execution and that the program will be implemented, as appli cable, for all phases of the project, including any activities important to safety that have been carried out prior to submittal of the license application.

This program should cover the engineering aspects of the site investiga tion, facility design, procurement, shop fabrication, onsite construction, preoperational testing, conduct of operations, and ultimate decommissioning.

The emphasis of this program should be on those activities and items that are identified as being important to safety. The planned QA effort should be com mensurate with the importance to safety of the identified activities and items. A QA program that has been approved by the NRC as meeting Appendix B to 10 CFR Part 50 or Subpart G of 10 CFR Part 72 may be applied to the spent fuel storage system.* The applicant should state the intent to implement this QA program for the ISFSI or MRS, the date on which the QA program was submitted to the NRC, the docket number, and the date of NRC approval.

states "A Commission-approved quality assurance program which satisfies the applicable criteria of Appendix B to Part 50 of this chapter and which is established, maintained, and executed with regard to an ISFSI will be accepted as satisfying the requirements of paragraph (b) of this section." 3.50-6

7. OPERATOR TRAINING Subpart I, "Training and Certification of Personnel," of 10 CFR Part 72 -requires that a personnel training program be established and that the program be submitted for NRC approval.

A brief summary of the program should be in cluded in the application.

Applicants who have an approved training program in effect may modify this program to cover spent fuel storage operations.

A description of the proposed changes should be provided.

ISFSI and MRS operators are not required to be licensed.

However, they must have successfully completed an established training program. Appropriate documentation of training activities and certifications of proficiency should be included in the ISFSI or MRS records.

In addition to the specific operating requirements of the planned facil ity, the training program should include the nuclear engineering principles, NRC regulations, regulatory guides, and national standards applicable to ISFSI or MRS operations.

Information on the content of the required training program is available from the Fuel Cycle Safety Branch, Division of Industrial and Med ical Nuclear Safety, Office of Nuclear Material Safety and Safeguards, U.S. Nuclear Regulatory Commission, Washington, DC 20555.3.50-7

8. INVENTORY

AND RECORDS REQUIREMENTS

A description of the inventory and records system for the stored spent fuel and high-level radioactive waste should be included in the license application.

Section 72.72 identifies the inventory and record requirements for radioactive material stored at an ISFSI or MRS. The records on the identity of each fuel assembly or high-level radioactive waste container should be complete.

As a minimum, these records should include: 1. For Spent Fuel a. Fuel manufacturer, b. Date of manufacture, c. Reactor exposure history, d. Burnup, e. Calculated special nuclear material content, f. Inventory control number, g. Pertinent data on discharge and storage at the reactor, transfer to the ISFSI or MRS, and storage at the ISFSI or MRS, h. For consolidated spent fuel, the records should show how the fuel rods can be traced to the original fuel assembly.

2. For High-Level Radioactive Waste a. Origin of waste, b. Calculations of isotope and curie content whenever they are necessary, c. Waste form, d. Thermal output, e. Inventory control number, f. Pertinent data on waste stabilization operations, transfer to the MRS, and storage at the MRS.3.50-8

9. PHYSICAL PROTECTION

Subpart H, "Physical Protection," of 10 CFR Part 72 requires that a physi cal security plan and guard training plan (§ 72.180), a design for physical pro tection (§ 72.182), and a safeguards contingency plan (§ 72.184) be submitted.

Since the details of the provisions for physical protection are withheld from public disclosure, these reports should be submitted separately.

The license application should contain only a reference to the identity of the reports and when they were submitted.

Specific guidance on these submittals for an MRS or an ISFSI not located on a nuclear power reactor site may be obtained from the Safeguards Licensing Branch, Office of Nuclear Material Safety and Safeguards, U.S. Nuclear Regula tory Commission, Washington, DC 20555. Reactor licensees may obtain guidance on these topics from the Reactor Safeguards Branch, Office of Nuclear Reactor Regulation, U.S. Nuclear Regulatory Commission, Washington, DC 20555. If the applicant has a physical security plan and a safeguards contingency plan that have been approved by NRC, modifications may be made to cover spent fuel storage operations.

A description of, and a schedule for, changes related to the spent fuel storage installation should be provided.3.50-9

1

0. DECOMMISSIONING

PLAN Section 72.30, "Decommissioning Planning, Including Financing and Record keeping," requires submittal of a proposed decommissioning plan, including a proposed funding plan that contains information on how funds will be available to decommission the ISFSI or MRS. The application should contain a description of the practices and procedures for decommissioning and an explanation of how the costs of decommissioning will be financed.

Applicants who have previously submitted proposed decommissioning plans (i.e., nuclear power reactor licensees)

may show how these plans will include the spent fuel storage installation.

3.50-10

1

1. EMERGENCY

PLAN The applicant should submit a plan for coping with emergencies as a sep arate document.

If the ISFSI is located on the site of a nuclear power reactor, the emergency plan required by § 50.47 of 10 CFR Part 50 satisfies the require ments of § 72.32 of 10 CFR Part 72.3.50-11

1

2. ENVIRONMENTAL

REPORT Section 72.34 requires that an environmental report be provided as part of the license application.

Guidance on the format and content of an environ mental report for an ISFSI may be found in Subpart A of 10 CFR Part 51, "Envi ronmental Protection Regulations for Domestic Licensing and Related Regulatory Functions." In the interest of keeping the size of this report within reasonable bounds and its structure and language keyed to the general public, it is recom mended that a prospective applicant confer with the NRC staff to obtain defini tive guidance on the scope and content of this report.3.50-12

13. PROPOSED LICENSE CONDITIONS

License conditions proposed by an applicant constitute a commitment by the applicant to take the actions specified therein. License conditions can be con sidered in two broad categories:

(1) administrative and management organization and controls and (2) technical specifications.

Those addressing administrative and management subjects should be included in the license application;

those ad dressing technical specifications should be described briefly in the license ap plication with appropriate references to the detailed analyses in the SAR. Care should be taken to ensure that such references are clear and explicit.

Proposed license conditions should address such subjects as: 1. Administrative and management organization, procedures, controls (in cluding review and approval activities), and auditing and reporting require ments. In particular, the subject of interfaces between the licensee and its contractors should be discussed.

2. Verification of design features that are important to safety. Those quality assurance activities that confirm that design and construction are being carried out in accordance with plans, e.g., inspection hold points, should be discussed.

In particular, identify who is responsible for performing this veri fication.

3. Test procedures.

Such subjects as conditions applicable to site eval uation, component testing during design and construction, preoperational testing prior to startup, and conditions applicable to tests that may be desirable after the commencement of operations should be discussed.

4. Functional and operating limits, monitoring instruments and limiting control settings.

The operating limits necessary for (a) protecting the integ rity of the spent fuel or solidified high-level radioactive waste, (b) protect ing employees against radiation exposure, and (c) preventing uncontrolled release of radioactive material should be discussed.

Radiation monitoring instruments and their limiting control settings should be described.

5. Limiting conditions of operation.

The functional capabilities or per formance levels of equipment and systems that are important to safety should be addressed.

The subject includes setpoint limits on monitoring instruments and any controls that may need to be imposed on personnel access to any part of the installation.

6. Surveillance requirements.

Such items as the periodic inspection of cranes and storage structures and, for water pools, water purity and evidence of corrosion should be covered.3.50-13 VALUE/IMPACT

STATEMENT A draft value/impact statement was published with the proposed Revision 1 to Regulatory Guide 3.50 (Task CE 402-4) when the draft guide was published for public comment in September

1986. No changes were necessary, so a separate value/impact statement for the final guide has not been prepared.

A copy of the draft value/impact statement is available for inspection and copying for a fee at the Commission's Public Document Room at 2120 L Street NW., Washington, DC, under Task CE 402-4.3.50-14 UNITED STATES NUCLEAR REGULATORY

COMMISSION

WASHINGTON, D.C. 20555 OFFICIAL BUSINESS PENALTY FOR PRIVATE USE, $300 FIRST CLASS MAIL POSTAGE & FEES PAID USNRC PERMIT No. G-67