05000382/FIN-2012004-04: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
 
(Created page by program invented by StriderTol)
Line 1: Line 1:
{{finding
{{finding
| title = Failure To Adequately Access And Manage Risk Before Performing Maintenance Activities Associated With Non-Standard Lifts
| title = Failure to Adequately Access and Manage Risk Before Performing Maintenance Activities Associated with Non-Standard Lifts
| docket = 05000382
| docket = 05000382
| inspection report = IR 05000382/2012004
| inspection report = IR 05000382/2012004

Revision as of 19:46, 20 February 2018

04
Site: Waterford Entergy icon.png
Report IR 05000382/2012004 Section 1R13
Date counted Sep 30, 2012 (2012Q3)
Type: NCV: Green
cornerstone Initiating Events
Identified by: NRC identified
Inspection Procedure: IP 71111.13
Inspectors (proximate) P Elkmann
M Davis
D Allen
W Sifre
J Laughlin
R Cureton
R Azua
D Overland
C Speer
CCA H.13, Consistent Process
INPO aspect DM.1
'