ML24031A660: Difference between revisions
StriderTol (talk | contribs) (StriderTol Bot change) |
StriderTol (talk | contribs) (StriderTol Bot change) |
||
| Line 17: | Line 17: | ||
=Text= | =Text= | ||
{{#Wiki_filter:Krishna P. Singh Technology Campus, 1 Holtec Blvd., Camden, NJ 08104 Telephone (856) 797- 0900 Fax (856) 797- 0909 | {{#Wiki_filter:Krishna P. Singh Technology Campus, 1 Holtec Blvd., Camden, NJ 08104 Telephone (856) 797-0900 Fax (856) 797-0909 Document ID: 5021074 Page 1 of 1 January 31, 2024 Ms. Kristina Banovac, Project Manager Division of Spent Fuel Office of Nuclear Material Safety and Safeguards U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 Docket No. 72-1040 Certificate of Compliance (CoC) No. 1040 | ||
January 31, 2024 | |||
Ms. Kristina Banovac, Project Manager Division of Spent Fuel Office of Nuclear Material Safety and Safeguards | |||
U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 | |||
Docket No. 72-1040 Certificate of | |||
==Subject:== | ==Subject:== | ||
Submittal of RSI Responses for Revision to HI-STORM UMAX CoC Amendments 0, 1, and 2 | Submittal of RSI Responses for Revision to HI-STORM UMAX CoC Amendments 0, 1, and 2 Reference [1] Application for Revision to Amendment Nos. 0, 1, and 2 of the Certificate of Compliance No. 1040 for the HI-STORM UMAX Canister Storage System - | ||
Supplemental Information Needed - Enterprise Project Identification Number L-2023-LLA-0070, from K. Banovac (NRC) to K. Manzione (Holtec), dated 12/18/23 | |||
Reference [1] Application for Revision to Amendment Nos. 0, 1, and 2 of the Certificate of Compliance No. 1040 for the HI-STORM UMAX Canister Storage System - | |||
Supplemental Information Needed - Enterprise Project Identification Number L-2023-LLA-0070, from K. Banovac (NRC) to K. Manzione (Holtec), dated 12/18/23 | |||
==Dear Ms. Banovac:== | ==Dear Ms. Banovac:== | ||
Holtec is pleased to submit the attached responses to the staffs RSI on the revisions HI-STORM UMAX CoC Amendments 0, 1, 2. The attachments contain the responses and marked up proposed revisions to the | Holtec is pleased to submit the attached responses to the staffs RSI on the revisions HI-STORM UMAX CoC Amendments 0, 1, 2. The attachments contain the responses and marked up proposed revisions to the FSARs associated with each CoC. | ||
If you have any questions, please contact me at (856)-797-0900 ext. 3951. | |||
If you have any questions, | Sincerely, Kimberly Manzione Director of Licensing - NMSS Projects Holtec International Attachments : Responses to RSIs for Revision 1 to Amendments 0, 1, and 2 : HI-STORM UMAX FSAR Proposed FSAR Revision 2.1A : HI-STORM UMAX FSAR Proposed FSAR Revision 3.1A : HI-STORM UMAX FSAR Proposed FSAR Revision 4.1A}} | ||
Sincerely, | |||
Kimberly Manzione Director of Licensing - NMSS Projects Holtec International | |||
Attachments : Responses to RSIs for Revision 1 to Amendments 0, 1, and 2 : HI -STORM UMAX FSAR Proposed FSAR Revision 2.1A : HI -STORM UMAX FSAR Proposed FSAR Revision 3.1A : HI -STORM UMAX FSAR Proposed FSAR Revision 4.1A | |||
Latest revision as of 20:35, 24 November 2024
| ML24031A660 | |
| Person / Time | |
|---|---|
| Site: | HI-STORM 100 |
| Issue date: | 01/31/2024 |
| From: | Manzione K Holtec |
| To: | Kristina Banovac Office of Nuclear Material Safety and Safeguards, Document Control Desk |
| Shared Package | |
| ML24031A659 | List: |
| References | |
| 5021074 | |
| Download: ML24031A660 (1) | |
Text
Krishna P. Singh Technology Campus, 1 Holtec Blvd., Camden, NJ 08104 Telephone (856) 797-0900 Fax (856) 797-0909 Document ID: 5021074 Page 1 of 1 January 31, 2024 Ms. Kristina Banovac, Project Manager Division of Spent Fuel Office of Nuclear Material Safety and Safeguards U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 Docket No. 72-1040 Certificate of Compliance (CoC) No. 1040
Subject:
Submittal of RSI Responses for Revision to HI-STORM UMAX CoC Amendments 0, 1, and 2 Reference [1] Application for Revision to Amendment Nos. 0, 1, and 2 of the Certificate of Compliance No. 1040 for the HI-STORM UMAX Canister Storage System -
Supplemental Information Needed - Enterprise Project Identification Number L-2023-LLA-0070, from K. Banovac (NRC) to K. Manzione (Holtec), dated 12/18/23
Dear Ms. Banovac:
Holtec is pleased to submit the attached responses to the staffs RSI on the revisions HI-STORM UMAX CoC Amendments 0, 1, 2. The attachments contain the responses and marked up proposed revisions to the FSARs associated with each CoC.
If you have any questions, please contact me at (856)-797-0900 ext. 3951.
Sincerely, Kimberly Manzione Director of Licensing - NMSS Projects Holtec International Attachments : Responses to RSIs for Revision 1 to Amendments 0, 1, and 2 : HI-STORM UMAX FSAR Proposed FSAR Revision 2.1A : HI-STORM UMAX FSAR Proposed FSAR Revision 3.1A : HI-STORM UMAX FSAR Proposed FSAR Revision 4.1A