{{#Wiki_filter:Krishna P. Singh Technology Campus, 1 Holtec Blvd., Camden, NJ 08104 Telephone (856) 797- 0900 Fax (856) 797- 0909
{{#Wiki_filter:Krishna P. Singh Technology Campus, 1 Holtec Blvd., Camden, NJ 08104 Telephone (856) 797-0900 Fax (856) 797-0909 Document ID: 5021074 Page 1 of 1 January 31, 2024 Ms. Kristina Banovac, Project Manager Division of Spent Fuel Office of Nuclear Material Safety and Safeguards U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 Docket No. 72-1040 Certificate of Compliance (CoC) No. 1040  
 
January 31, 2024
 
Ms. Kristina Banovac, Project Manager Division of Spent Fuel Office of Nuclear Material Safety and Safeguards
 
U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001
 
Docket No. 72-1040 Certificate of Complia nce (CoC) No. 1040


==Subject:==
==Subject:==
Submittal of RSI Responses for Revision to HI-STORM UMAX CoC Amendments 0, 1, and 2
Submittal of RSI Responses for Revision to HI-STORM UMAX CoC Amendments 0, 1, and 2 Reference [1] Application for Revision to Amendment Nos. 0, 1, and 2 of the Certificate of Compliance No. 1040 for the HI-STORM UMAX Canister Storage System -
 
Supplemental Information Needed - Enterprise Project Identification Number L-2023-LLA-0070, from K. Banovac (NRC) to K. Manzione (Holtec), dated 12/18/23  
Reference [1] Application for Revision to Amendment Nos. 0, 1, and 2 of the Certificate of Compliance No. 1040 for the HI-STORM UMAX Canister Storage System -
Supplemental Information Needed - Enterprise Project Identification Number L-2023-LLA-0070, from K. Banovac (NRC) to K. Manzione (Holtec), dated 12/18/23


==Dear Ms. Banovac:==
==Dear Ms. Banovac:==
Holtec is pleased to submit the attached responses to the staffs RSI on the revisions HI-STORM UMAX CoC Amendments 0, 1, 2. The attachments contain the responses and marked up proposed revisions to the FSAR s associated with each CoC.
Holtec is pleased to submit the attached responses to the staffs RSI on the revisions HI-STORM UMAX CoC Amendments 0, 1, 2. The attachments contain the responses and marked up proposed revisions to the FSARs associated with each CoC.
 
If you have any questions, please contact me at (856)-797-0900 ext. 3951.
If you have any questions, pleasecontact me at (856)-797-0900 ext. 3951.
Sincerely, Kimberly Manzione Director of Licensing - NMSS Projects Holtec International Attachments : Responses to RSIs for Revision 1 to Amendments 0, 1, and 2 : HI-STORM UMAX FSAR Proposed FSAR Revision 2.1A : HI-STORM UMAX FSAR Proposed FSAR Revision 3.1A : HI-STORM UMAX FSAR Proposed FSAR Revision 4.1A}}
 
Sincerely,
 
Kimberly Manzione Director of Licensing - NMSS Projects Holtec International
 
Attachments : Responses to RSIs for Revision 1 to Amendments 0, 1, and 2 : HI -STORM UMAX FSAR Proposed FSAR Revision 2.1A : HI -STORM UMAX FSAR Proposed FSAR Revision 3.1A : HI -STORM UMAX FSAR Proposed FSAR Revision 4.1A
 
Document ID: 5021074 Page 1 of 1}}

Latest revision as of 20:35, 24 November 2024

International, Submittal of Rsi Responses for Revision to HI-STORM Umax CoC Amendments 0, 1, and 2
ML24031A660
Person / Time
Site: HI-STORM 100
Issue date: 01/31/2024
From: Manzione K
Holtec
To: Kristina Banovac
Office of Nuclear Material Safety and Safeguards, Document Control Desk
Shared Package
ML24031A659 List:
References
5021074
Download: ML24031A660 (1)


Text

Krishna P. Singh Technology Campus, 1 Holtec Blvd., Camden, NJ 08104 Telephone (856) 797-0900 Fax (856) 797-0909 Document ID: 5021074 Page 1 of 1 January 31, 2024 Ms. Kristina Banovac, Project Manager Division of Spent Fuel Office of Nuclear Material Safety and Safeguards U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 Docket No. 72-1040 Certificate of Compliance (CoC) No. 1040

Subject:

Submittal of RSI Responses for Revision to HI-STORM UMAX CoC Amendments 0, 1, and 2 Reference [1] Application for Revision to Amendment Nos. 0, 1, and 2 of the Certificate of Compliance No. 1040 for the HI-STORM UMAX Canister Storage System -

Supplemental Information Needed - Enterprise Project Identification Number L-2023-LLA-0070, from K. Banovac (NRC) to K. Manzione (Holtec), dated 12/18/23

Dear Ms. Banovac:

Holtec is pleased to submit the attached responses to the staffs RSI on the revisions HI-STORM UMAX CoC Amendments 0, 1, 2. The attachments contain the responses and marked up proposed revisions to the FSARs associated with each CoC.

If you have any questions, please contact me at (856)-797-0900 ext. 3951.

Sincerely, Kimberly Manzione Director of Licensing - NMSS Projects Holtec International Attachments : Responses to RSIs for Revision 1 to Amendments 0, 1, and 2 : HI-STORM UMAX FSAR Proposed FSAR Revision 2.1A : HI-STORM UMAX FSAR Proposed FSAR Revision 3.1A : HI-STORM UMAX FSAR Proposed FSAR Revision 4.1A