ML20154R930: Difference between revisions
StriderTol (talk | contribs) (StriderTol Bot change) |
StriderTol (talk | contribs) (StriderTol Bot change) |
||
| Line 19: | Line 19: | ||
=Text= | =Text= | ||
{{#Wiki_filter:- | {{#Wiki_filter:- | ||
t, S. | t, S. | ||
I 2 | I 2 | ||
RANCHO SECO UNIT 1 TECHNICAL SPECIFICATIONS | RANCHO SECO UNIT 1 TECHNICAL SPECIFICATIONS TABLE OF CONTENTS (Continued) i Section Page 1.5 INSTRUMENTATION SURVEILLANCE 1-3 1.5.1 Trip Test 1-3 l | ||
1.5.2 Channel Test 1-3 l | |||
1.5.3 Instrument Channel Check 1-3 1.5.4 Instrument Channel Calibration 1-4 1.5.5 Heat Balance Check 1-4 4 | |||
1.5.4 | 1.5.6 Heat Balance Calibration 1-4 1.6 QUADRANT POWER TILT 1-4 1.6.1 Reactor Power Imbalance 1-4 1.7 CONTAINMENT INTEGRITY 1-4 1.8 REPORTABLE OCCURRENCE 1-5 l | ||
1.5.5 | 1.9 TIME PERIODS 1-5 1.9.1 Shift 1-5 i | ||
1.9.2 Weekly 1-5 | |||
) | |||
1.9.3 Daily 1.5 136> | |||
) | 1.9.4 Fortnightly 1-5 1.9.5 Monthly 1-5 1.9.6 Quarterly 1-5 I | ||
1.9.7 Semi-Annually 1-5 1.9.8 Annua 1ly 1-5 1.9.9 Biannually 1-5 1.9.10 Refueling Interval 1-5 1.10 SAFETY 1-5 1.11 FIRE SUPPRESSION SYSTEMS 1-6 1.12 STAGGERED TEST BASIS 1-6 1.13 PROCESS CONTROL PROGRAM 1-6 l | |||
1.14 SOLIDIFICATION 1-6 1.15 0FFSITE DOSE CALCULATION MANUAL (0DCM) 1-7 1 | |||
Proposed Amendment No. 136 i | |||
11 | |||
'e | |||
'. ~. | |||
l RANCHO SECO UNIT 1 TECHNICAL SPECIFICATIONS | l RANCHO SECO UNIT 1 TECHNICAL SPECIFICATIONS Definitions I | ||
All automatic containment isolation valves are operable or closed | |||
~ | |||
D. | |||
in the safety features position. | |||
'i j | 'i j | ||
E. | |||
i | The containment leakage satisfies Specification 4.4.1 and no known changes have occurred. | ||
i 1.8 LICENSEE EVENT REPORTS Defined under Administrative Controls Section 6.9.4. | |||
I 1.9 TIME PERIODS May be extended to a maximum of +25% to accomodate operations scheduling. | I 1.9 TIME PERIODS May be extended to a maximum of +25% to accomodate operations scheduling. | ||
136>< The total maximum combined interval time for any three consecutive intervals shall not exceed 3.25 times a single specified surveillance interval. | 136>< The total maximum combined interval time for any three consecutive intervals shall not exceed 3.25 times a single specified surveillance interval. | ||
1.9.1 | 1.9.1 SHIFT A time period covering at least once per twelve (12) hours. | ||
1.9.2 | 1.9.2 DAILY A time period spaced to occur at least once per twenty-four (24) hours. | ||
1.9.3 | 1.9.3 WEEKLY A time period spaced to occur at least once per seven (7) days. | ||
136> | |||
1.9.4 FORTNIGHTLY 4 | |||
A time period spaced to occur once per fourteen (14) days. | 1 A time period spaced to occur once per fourteen (14) days. | ||
1.9.5 | 1.9.5 MONTHLY A time period spaced to occur at least once per thirty-one (31) days. | ||
1.9.6 | 1.9.6 QUARTERLY A time period spaced to occur at least once per ninety-two (92) days. | ||
1.9.7 | 1.9.7 SEMI-ANNUALLY A time period spaced to occur at least once per six (6) months. | ||
1.9.8 | 1.9.8 ANNUALLY i | ||
A time period spaced to occur at least once per twelve (12) months. | A time period spaced to occur at least once per twelve (12) months. | ||
1.9.9 | 1.9.9 BIANNUALLY A time period spaced to occur at least once in two (2) years. | ||
1.9.10 REFUELING INTERVAL A time period spaced to occur at least once per eighteen (18) months. | |||
] | ] | ||
j | j 1.10 SAFETY Safety as used in these Technical Specifications shall mean nuclear safety i | ||
Safety as used in these Technical Specifications shall mean nuclear safety i | i and shall en' compass all systems and components that have or may have an effect on the health and safety of the general public. | ||
j | j Proposed Amendment No.136 1-5 | ||
- -}} | |||
Latest revision as of 22:52, 10 December 2024
| ML20154R930 | |
| Person / Time | |
|---|---|
| Site: | Rancho Seco |
| Issue date: | 03/20/1986 |
| From: | SACRAMENTO MUNICIPAL UTILITY DISTRICT |
| To: | |
| Shared Package | |
| ML20154R928 | List: |
| References | |
| TAC-61472, NUDOCS 8603310248 | |
| Download: ML20154R930 (2) | |
Text
-
t, S.
I 2
RANCHO SECO UNIT 1 TECHNICAL SPECIFICATIONS TABLE OF CONTENTS (Continued) i Section Page 1.5 INSTRUMENTATION SURVEILLANCE 1-3 1.5.1 Trip Test 1-3 l
1.5.2 Channel Test 1-3 l
1.5.3 Instrument Channel Check 1-3 1.5.4 Instrument Channel Calibration 1-4 1.5.5 Heat Balance Check 1-4 4
1.5.6 Heat Balance Calibration 1-4 1.6 QUADRANT POWER TILT 1-4 1.6.1 Reactor Power Imbalance 1-4 1.7 CONTAINMENT INTEGRITY 1-4 1.8 REPORTABLE OCCURRENCE 1-5 l
1.9 TIME PERIODS 1-5 1.9.1 Shift 1-5 i
1.9.2 Weekly 1-5
)
1.9.3 Daily 1.5 136>
1.9.4 Fortnightly 1-5 1.9.5 Monthly 1-5 1.9.6 Quarterly 1-5 I
1.9.7 Semi-Annually 1-5 1.9.8 Annua 1ly 1-5 1.9.9 Biannually 1-5 1.9.10 Refueling Interval 1-5 1.10 SAFETY 1-5 1.11 FIRE SUPPRESSION SYSTEMS 1-6 1.12 STAGGERED TEST BASIS 1-6 1.13 PROCESS CONTROL PROGRAM 1-6 l
1.14 SOLIDIFICATION 1-6 1.15 0FFSITE DOSE CALCULATION MANUAL (0DCM) 1-7 1
Proposed Amendment No. 136 i
11
'e
'. ~.
l RANCHO SECO UNIT 1 TECHNICAL SPECIFICATIONS Definitions I
All automatic containment isolation valves are operable or closed
~
D.
in the safety features position.
'i j
E.
The containment leakage satisfies Specification 4.4.1 and no known changes have occurred.
i 1.8 LICENSEE EVENT REPORTS Defined under Administrative Controls Section 6.9.4.
I 1.9 TIME PERIODS May be extended to a maximum of +25% to accomodate operations scheduling.
136>< The total maximum combined interval time for any three consecutive intervals shall not exceed 3.25 times a single specified surveillance interval.
1.9.1 SHIFT A time period covering at least once per twelve (12) hours.
1.9.2 DAILY A time period spaced to occur at least once per twenty-four (24) hours.
1.9.3 WEEKLY A time period spaced to occur at least once per seven (7) days.
136>
1.9.4 FORTNIGHTLY 4
1 A time period spaced to occur once per fourteen (14) days.
1.9.5 MONTHLY A time period spaced to occur at least once per thirty-one (31) days.
1.9.6 QUARTERLY A time period spaced to occur at least once per ninety-two (92) days.
1.9.7 SEMI-ANNUALLY A time period spaced to occur at least once per six (6) months.
1.9.8 ANNUALLY i
A time period spaced to occur at least once per twelve (12) months.
1.9.9 BIANNUALLY A time period spaced to occur at least once in two (2) years.
1.9.10 REFUELING INTERVAL A time period spaced to occur at least once per eighteen (18) months.
]
j 1.10 SAFETY Safety as used in these Technical Specifications shall mean nuclear safety i
i and shall en' compass all systems and components that have or may have an effect on the health and safety of the general public.
j Proposed Amendment No.136 1-5
- -