{{#Wiki_filter:REACTOR COOLANT SYSTEM OPERATING LIMITING CONDITION FOR OPERATION 3.4.2.2 All pressurizer Code safety valves shall be OPERABLE with a lift setting' of 2485 psig + 2%, 3%. 2 | {{#Wiki_filter:REACTOR COOLANT SYSTEM OPERATING LIMITING CONDITION FOR OPERATION 3.4.2.2 All pressurizer Code safety valves shall be OPERABLE with a lift setting' of 2485 psig + 2%, 3%. 2 I | ||
APPLICABILITY: | |||
MODES 1, 2, and 3. | |||
ACTION: | ACTION: | ||
With one pressurizer Code safety valve inoperable, either restore the inoperable valve to OPERABLE status within 1 hour or be in at least H-OT STANDBY within 6 hours and In at least HOT SHUTDOWN within the following 6 hours. | With one pressurizer Code safety valve inoperable, either restore the inoperable valve to OPERABLE status within 1 hour or be in at least H-OT STANDBY within 6 hours and In at least HOT SHUTDOWN within the following 6 hours. | ||
SURVEILLANCE REQUIREMENTS 4.4.2.2 | SURVEILLANCE REQUIREMENTS 4.4.2.2 No additional requirements other than those required by Specification 4.0.5. | ||
'The lift setting pressure shall correspond to ambient conditions of the valve at nominal operating temperature and pressure. | 'The lift setting pressure shall correspond to ambient conditions of the valve at nominal operating temperature and pressure. | ||
2The | 2The as left lift setting shall be within +1% following valve testing. | ||
SOUTH TEXAS - UNITS 1 & 2 | SOUTH TEXAS - UNITS 1 & 2 314 4-8 Unit 1 - Amendment No. 59T78,159 Unit2-AmendmentNo. 47;67,147}} | ||
Latest revision as of 06:16, 16 January 2025
| ML033390089 | |
| Person / Time | |
|---|---|
| Site: | South Texas |
| Issue date: | 12/02/2003 |
| From: | NRC/NRR/DLPM |
| To: | |
| References | |
| Download: ML033390089 (1) | |
Text
REACTOR COOLANT SYSTEM OPERATING LIMITING CONDITION FOR OPERATION 3.4.2.2 All pressurizer Code safety valves shall be OPERABLE with a lift setting' of 2485 psig + 2%, 3%. 2 I
APPLICABILITY:
MODES 1, 2, and 3.
ACTION:
With one pressurizer Code safety valve inoperable, either restore the inoperable valve to OPERABLE status within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> or be in at least H-OT STANDBY within 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and In at least HOT SHUTDOWN within the following 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />.
SURVEILLANCE REQUIREMENTS 4.4.2.2 No additional requirements other than those required by Specification 4.0.5.
'The lift setting pressure shall correspond to ambient conditions of the valve at nominal operating temperature and pressure.
2The as left lift setting shall be within +1% following valve testing.
SOUTH TEXAS - UNITS 1 & 2 314 4-8 Unit 1 - Amendment No. 59T78,159 Unit2-AmendmentNo. 47;67,147