ML072480572: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
(StriderTol Bot change)
 
(One intermediate revision by the same user not shown)
Line 2: Line 2:
| number = ML072480572
| number = ML072480572
| issue date = 06/15/2007
| issue date = 06/15/2007
| title = Gnf S-0000-0068-2643, Gnf Additional Information Regarding the Requested Changes to the Technical Specification Slmcpr. Hope Creek (KT1) Cycle 15
| title = GNF S-0000-0068-2643, GNF Additional Information Regarding the Requested Changes to the Technical Specification Slmcpr. Hope Creek (KT1) Cycle 15
| author name =  
| author name =  
| author affiliation = Global Nuclear Fuel - Americas, LLC
| author affiliation = Global Nuclear Fuel - Americas, LLC
Line 21: Line 21:
{{#Wiki_filter:ATTACHMENT 3 Hope Creek Generating Station Facility Operating License No. NPF-57 NRC Docket No. 50-354 Extended Power Uprate GNF Hope Creek C15 SLMCPR - Non-Proprietary Letter
{{#Wiki_filter:ATTACHMENT 3 Hope Creek Generating Station Facility Operating License No. NPF-57 NRC Docket No. 50-354 Extended Power Uprate GNF Hope Creek C15 SLMCPR - Non-Proprietary Letter


GNF NON-PROPRIETARY INFORMATION Class I           GNF S-0000-0068-2643 GNF Attachment 6/15/2007 GNF S-0000-0068-2643 GNF Additional Information Regarding the Requested Changes to the Technical Specification SLMCPR Hope Creek (KT1) Cycle 15 Hope Creek (KT1) Cycle 15                                           Page 1 of 21
GNF NON-PROPRIETARY INFORMATION Class I GNF S-0000-0068-2643 GNF Attachment 6/15/2007 GNF S-0000-0068-2643 GNF Additional Information Regarding the Requested Changes to the Technical Specification SLMCPR Hope Creek (KT1) Cycle 15 Hope Creek (KT1) Cycle 15 Page 1 of 21


GNF NON-PROPRIETARY INFORMATION Class I                 GNF S-0000-0068-2643 GNF Attachment Proprietary Information Notice This document is the GNF non-proprietary version of the GNF proprietary report. From the GNF proprietary version, the information denoted as GNF proprietary (enclosed in double brackets) was deleted to generate this version.
GNF NON-PROPRIETARY INFORMATION Class I GNF S-0000-0068-2643 GNF Attachment Proprietary Information Notice This document is the GNF non-proprietary version of the GNF proprietary report. From the GNF proprietary version, the information denoted as GNF proprietary (enclosed in double brackets) was deleted to generate this version.
Proprietary Information Notice                                                   Page 2 of 21
Proprietary Information Notice Page 2 of 21


GNF NON-PROPRIETARY INFORMATION Class I                                                   GNF S-0000-0068-2643 GNF Attachment Table of Contents 1.0       M ETH O D O LO G Y ..........................................................................................................................................           4 2.0       D ISC U SSIO N ...................................................................................................................................................       4 2.1.       M AJOR CONTRIBUTORS TO SLM CPR CHANGE ..........................................................................................                                     4 2.2.       DEVIATIONS IN N RC-APPROVED U NCERTAINTIES .....................................................................................                                     5 2.2.1.       R-Factor.................................................................................................................................................     5 2.2.2.       Core Flow Rate and Random Effective TIP Reading.......................................................................                                         5 2.2.3.       Reactor PressureM easurement ....................................................................................................                             6 2.3.       DEPARTURE FROM NRC-A PPROVED M ETHODOLOGY. ...............................................................................                                           6 2.4.       FUEL A XIAL POWER SHAPE PENALTY ...................................................................................................                                 7 2.5.       M ETHODOLOGY RESTRICTIONS ......................................................................................................................                     8 2.6.       M IN IM UM CORE FLOW CONDITION ................................................................................................................                     8 2.7.       LIM ITING CONTROL ROD PATTERNS ...............................................................................................................                       8 2.8.       CORE M ONITORING SYSTEM ..........................................................................................................................                   8 2.9.       POWER/FLOW M AP .........................................................................................................................................           8 2.10.       CORE LOADING D IAGRAM ..........................................................................................................................                   8 2.1 1.       FIGURE REFERENCES ..................................................................................................................................               8 2.12.       A DDITIONAL SLM CPR LICENSING CONDITIONS ...................................................................................                                       9 2.13.       SUM MARY ..................................................................................................................................................       9 3.0       REFER EN C ES ..............................................................................................................................................           10 List of Figures FIGURE     1. CURRENT CYCLE CORE LOADIN G D IAGRAM ..............................................................................................                               11 FIGURE   2. PREVIOUS CYCLE CORE LOADING D IAGRAM .........................................................................................                                     12 FIGURE   3. FIGURE 4.1 FROM NED C-32601 -P-A .........................................................................................................                         13 FIGURE   4. FIGURE 111.5-1 FROM N EDC-32601P-A ......................................................................                                                         13 FIGURE   5. FIGURE 111.5-2 FROM N EDC-32601P-A .................................................................................................                               13 List of Tables TABLE 1.     D ESCRIPOPTION OF CORE .................................................................................................................................           14 TABLE 2.     SLM CPR CALCULATION M ETHODOLOGIES .............................................................................................                                   15 TABLE 3.     MONTE CARLO CALCULATED SLMCPR vs. ESTIMATE ..........................................................................                                               16 TABLE 4.     NON-POWER D ISTR IBUTION U NCERTAINTIES .........................................................................................                                   17 TABLE 5.     POWER D ISTRIB UTION U NCERTAINTIES .......................................................................................................                         19 TABLE 6.     CRITICAL POW ER U NCERTAINTIES ...............................................................................................................                     21 Table of Contents                                                                                                                                                       Page 3 of 21
GNF NON-PROPRIETARY INFORMATION Class I GNF S-0000-0068-2643 GNF Attachment Table of Contents 1.0 M ETH O D O LO G Y..........................................................................................................................................
4 2.0 D ISC U SSIO N...................................................................................................................................................
4 2.1.
M AJOR CONTRIBUTORS TO SLM CPR CHANGE.......................................................................................... 4 2.2.
D EVIATIONS IN N RC-APPROVED U NCERTAINTIES.....................................................................................
5 2.2.1.
R-Factor.................................................................................................................................................
5 2.2.2.
Core Flow Rate and Random Eff ective TIP Reading.......................................................................
5 2.2.3.
Reactor Pressure M easurem ent....................................................................................................
6 2.3.
D EPARTURE FROM N RC-A PPROVED M ETHODOLOGY................................................................................
6 2.4.
FUEL A XIAL POWER SHAPE PENALTY...................................................................................................
7 2.5.
M ETHODOLOGY RESTRICTIONS......................................................................................................................
8 2.6.
M IN IM UM CORE FLOW CONDITION................................................................................................................
8 2.7.
LIM ITING CONTROL ROD PATTERNS...............................................................................................................
8 2.8.
CORE M ONITORING SYSTEM..........................................................................................................................
8 2.9.
POWE R/FLOW M AP.........................................................................................................................................
8 2.10.
CORE LOADING D IAGRAM..........................................................................................................................
8 2.1 1.
FIGURE REFERENCES..................................................................................................................................
8 2.12.
A DDITIONAL SLM CPR LICENSING COND ITIONS...................................................................................
9 2.13.
SUM M ARY..................................................................................................................................................
9 3.0 RE FER EN C ES..............................................................................................................................................
10 List of Figures FIGURE 1. CURRENT CYCLE CORE LOADIN G D IA GRAM.............................................................................................. 11 FIGURE 2. PREVIOUS CYCLE CORE LOADING D IAGRAM.........................................................................................
12 FIGURE 3. FIGURE 4.1 FROM NED C-32601 -P-A......................................................................................................... 13 FIGURE 4. FIGURE 111.5-1 FROM N ED C-32601P-A...................................................................... 13 FIGURE 5. FIGURE 111.5-2 FROM N ED C-32601P-A.................................................................................................
13 List of Tables TABLE 1. D ESCRIPOPTION OF CORE.................................................................................................................................
14 TABLE 2. SLM CPR CALCULATION M ETHODOLOGIES............................................................................................. 15 TABLE 3. MONTE CARLO CALCULATED SLMCPR vs. ESTIMATE..........................................................................
16 TABLE 4. N ON-POWER D ISTR IBUTION U NCERTAINTIES.........................................................................................
17 TABLE 5. POWER D ISTRIB UTION U NCERTAINTIES....................................................................................................... 19 TABLE 6. CRITICAL POW ER U NCERTAINTIES...............................................................................................................
21 Table of Contents Page 3 of 21


GNF NON-PROPRIETARY INFORMATION Class I                   GNF S-0000-0068-2643 GNF Attachment 1.0 Methodology GNF performed the Hope Creek Cycle 15 Safety Limit Minimum Critical Power Ratio (SLMCPR) calculation in accordance to NEDE-24011-P-A "General Electric Standard Application for Reactor Fuel" (Revision 15) using the following NRC-approved methodologies and uncertainties:
GNF NON-PROPRIETARY INFORMATION Class I GNF S-0000-0068-2643 GNF Attachment 1.0 Methodology GNF performed the Hope Creek Cycle 15 Safety Limit Minimum Critical Power Ratio (SLMCPR) calculation in accordance to NEDE-24011-P-A "General Electric Standard Application for Reactor Fuel" (Revision 15) using the following NRC-approved methodologies and uncertainties:
* NEDC-32601P-A "Methodology and Uncertainties for Safety Limit MCPR Evaluations" (August 1999).
* NEDC-32601P-A "Methodology and Uncertainties for Safety Limit MCPR Evaluations" (August 1999).
* NEDC-32694P-A "Power Distribution Uncertainties for Safety Limit MCPR Evaluations" (August 1999).
* NEDC-32694P-A "Power Distribution Uncertainties for Safety Limit MCPR Evaluations" (August 1999).
Line 35: Line 75:
Table 2 identifies the actual methodologies used for the previous and current cycle SLMCPR calculations.
Table 2 identifies the actual methodologies used for the previous and current cycle SLMCPR calculations.
2.0 Discussion In this discussion, the TLO nomenclature is used for two recirculation loops in operation, and the SLO nomenclature is used for one recirculation loop in operation. The "Previous Cycle" is Cycle 14, and the "Current Cycle" is Cycle 15.
2.0 Discussion In this discussion, the TLO nomenclature is used for two recirculation loops in operation, and the SLO nomenclature is used for one recirculation loop in operation. The "Previous Cycle" is Cycle 14, and the "Current Cycle" is Cycle 15.
2.1. Major Contributors to SLMCPR Change In general, the calculated safety limit is dominated by two key parameters: (1) flatness of the core bundle-by-bundle MCPR distribution, and (2) flatness of the bundle pin-by-pin power/R-factor distribution. Greater flatness in either parameter yields more rods susceptible to boiling transition and thus a higher calculated SLMCPR. MIP (MCPR Importance Parameter) measures the core bundle-by-bundle MCPR distribution and RIP (R-factor Importance Parameter) measures the bundle pin-by-pin power/R-factor distribution. The impact of the fuel loading pattern on the calculated TLO SLMCPR using rated core power and rated core flow conditions has been correlated to the parameter MIPRIP, which combines the MIP and RIP values.
2.1.
Table 3 presents the MIP and RIP parameters for the previous cycle and the current cycle along with the TLO SLMCPR estimate using the MIPRIP correlation. If the minimum core flow case is applicable, the TLO SLMCPR estimate is also provided for that case although the MIPRIP correlation is only applicable to the rated core flow case. This is done only to provide some reasonable assessment basis of the minimum core flow case trend. In addition, Table 3 presents Methodology                                                                           Page 4 of 21
Major Contributors to SLMCPR Change In general, the calculated safety limit is dominated by two key parameters: (1) flatness of the core bundle-by-bundle MCPR distribution, and (2) flatness of the bundle pin-by-pin power/R-factor distribution. Greater flatness in either parameter yields more rods susceptible to boiling transition and thus a higher calculated SLMCPR. MIP (MCPR Importance Parameter) measures the core bundle-by-bundle MCPR distribution and RIP (R-factor Importance Parameter) measures the bundle pin-by-pin power/R-factor distribution. The impact of the fuel loading pattern on the calculated TLO SLMCPR using rated core power and rated core flow conditions has been correlated to the parameter MIPRIP, which combines the MIP and RIP values.
Table 3 presents the MIP and RIP parameters for the previous cycle and the current cycle along with the TLO SLMCPR estimate using the MIPRIP correlation. If the minimum core flow case is applicable, the TLO SLMCPR estimate is also provided for that case although the MIPRIP correlation is only applicable to the rated core flow case. This is done only to provide some reasonable assessment basis of the minimum core flow case trend. In addition, Table 3 presents Methodology Page 4 of 21


GNF NON-PROPRIETARY INFORMATION Class I                     GNF S-0000-0068-2643 GNF Attachment estimated impacts on the TLO SLMCPR due to methodology deviations, penalities, and/or uncertainties deviations from approved values. Based on the MIPRIP correlation and any impacts due to deviations from approved values, a final estimated TLO SLMCPR is determined.
GNF NON-PROPRIETARY INFORMATION Class I GNF S-0000-0068-2643 GNF Attachment estimated impacts on the TLO SLMCPR due to methodology deviations, penalities, and/or uncertainties deviations from approved values.
Table 3 also provides the actual calculated Monte Carlo SLMCPRs. Given the bias and uncertainty in the MIPRIP correlation [[ f31]] and the inherent variation in the Monte Carlo results [[ 13 W], the change in the Hope Creek Cycle 15 calculated Monte Carlo TLO SLMCPR using rated core power and rated core flow conditions is consistent with the corresponding estimated TLO SLMCPR value.
Based on the MIPRIP correlation and any impacts due to deviations from approved values, a final estimated TLO SLMCPR is determined.
Table 3 also provides the actual calculated Monte Carlo SLMCPRs.
Given the bias and uncertainty in the MIPRIP correlation ((
f31)) and the inherent variation in the Monte Carlo results ((
13W],
the change in the Hope Creek Cycle 15 calculated Monte Carlo TLO SLMCPR using rated core power and rated core flow conditions is consistent with the corresponding estimated TLO SLMCPR value.
2.2. Deviations in NRC-Approved Uncertainties Tables 4 and 5 provide a list of NRC-approved uncertainties along with values actually used. A discussion of deviations from these NRC-approved values follows; all of which are conservative relative to NRC-approved values. Also, estimated impact on the SLMCPR is provided in Table 3 for each deviation.
2.2. Deviations in NRC-Approved Uncertainties Tables 4 and 5 provide a list of NRC-approved uncertainties along with values actually used. A discussion of deviations from these NRC-approved values follows; all of which are conservative relative to NRC-approved values. Also, estimated impact on the SLMCPR is provided in Table 3 for each deviation.
2.2.1.       R-Factor At this time, GNF has generically increased the GEXL R-Factor uncertainty from [[ (3)]] to account for an increase in channel bow due to the emerging unforeseen phenomena called control blade shadow corrosion-induced channel bow, which is not accounted for in the channel bow uncertainty component of the approved R-Factor uncertainty. The step "aYRPEAK" in Figure 4.1 from NEDC-32601P-A, which has been provided for convenience in Figure 3 of this attachment, is affected by this deviation. Reference 4 technically justifies that a GEXL R-Factor uncertainty of [[ 131]] accounts for a channel bow uncertainty of up to [[ (3)]].
2.2.1.
The Hope Creek Cycle 15 analysis has addressed the potential for shadow corrosion-induced channel bow by increasing the NRC-approved R-Factor uncertainty from [[ 13)]] to [[ f3(]].
R-Factor At this time, GNF has generically increased the GEXL R-Factor uncertainty from ((
Accounting for control blade shadow corrosion-induced channel bow, the Hope Creek Cycle 15 analysis shows an expected channel bow uncertainty of [[ 131]], which is bounded by a GEXL R-Factor uncertainty of [[ 131]]. Thus the use of a GEXL R-Factor uncertainty of [[ 13)]] adequately accounts for control blade shadow corrosion-induced channel bow for Hope Creek Cycle 15 and subsequent cycles that exhibit channel bow uncertainty of [[I13 )]].
(3))) to account for an increase in channel bow due to the emerging unforeseen phenomena called control blade shadow corrosion-induced channel bow, which is not accounted for in the channel bow uncertainty component of the approved R-Factor uncertainty.
2.2.2.       Core Flow Rate and Random Effective TIP Reading At this time, GNF has not been able to show that the NRC-approved process to calculate the SLMCPR only at the rated core power and rated core flow condition is adequately bounding relative to the SLMCPR calculated at rated core power and minimum core flow, see Reference 5.
The step "aY RPEAK" in Figure 4.1 from NEDC-32601P-A, which has been provided for convenience in Figure 3 of this attachment, is affected by this deviation. Reference 4 technically justifies that a GEXL R-Factor uncertainty of ((
131)) accounts for a channel bow uncertainty of up to (( (3))).
The Hope Creek Cycle 15 analysis has addressed the potential for shadow corrosion-induced channel bow by increasing the NRC-approved R-Factor uncertainty from (( 13))) to (( f3()).
Accounting for control blade shadow corrosion-induced channel bow, the Hope Creek Cycle 15 analysis shows an expected channel bow uncertainty of (( 131)), which is bounded by a GEXL R-Factor uncertainty of (( 131)). Thus the use of a GEXL R-Factor uncertainty of (( 1 3))) adequately accounts for control blade shadow corrosion-induced channel bow for Hope Creek Cycle 15 and subsequent cycles that exhibit channel bow uncertainty of (( I13))).
2.2.2.
Core Flow Rate and Random Effective TIP Reading At this time, GNF has not been able to show that the NRC-approved process to calculate the SLMCPR only at the rated core power and rated core flow condition is adequately bounding relative to the SLMCPR calculated at rated core power and minimum core flow, see Reference 5.
The minimum core flow condition can be more limiting due to the control rod pattern used.
The minimum core flow condition can be more limiting due to the control rod pattern used.
GNF has modified the NRC-approved process for determining the SLMCPR to include analyses at the rated core power and minimum licensed core flow point in addition to analyses at the rated core power and rated core flow point. GNF believes this modification is conservative and may in the future provide justification that the original NRC-approved process is adequately bounding.
GNF has modified the NRC-approved process for determining the SLMCPR to include analyses at the rated core power and minimum licensed core flow point in addition to analyses at the rated core power and rated core flow point. GNF believes this modification is conservative and may in the future provide justification that the original NRC-approved process is adequately bounding.
Discussion                                                                           Page 5 of 21
Discussion Page 5 of 21


GNF NON-PROPRIETARY INFORMATION Class I                   GNF S-0000-0068-2643 GNF Attachment For the TLO calculations performed at 94.8% core flow, the approved uncertainty values for the core flow rate (2.5%) and the random effective TIP reading (1.2%) are conservatively adjusted by dividing them by 94.8/100. The steps "a CORE FLOW" and "a TIP (INSTRUMENT)" in Figure 4.1 from NEDC-32601P-A, which has been provided for convenience in Figure 3 of this attachment) are affected by this deviation, respectively.
GNF NON-PROPRIETARY INFORMATION Class I GNF S-0000-0068-2643 GNF Attachment For the TLO calculations performed at 94.8% core flow, the approved uncertainty values for the core flow rate (2.5%) and the random effective TIP reading (1.2%) are conservatively adjusted by dividing them by 94.8/100. The steps "a CORE FLOW" and "a TIP (INSTRUMENT)" in Figure 4.1 from NEDC-32601P-A, which has been provided for convenience in Figure 3 of this attachment) are affected by this deviation, respectively.
Historically, these values have been construed to be somewhat dependent on the core flow conditions as demonstrated by the fact that higher values have always been used when performing SLO calculations. It is for this reason that GNF determined that it is appropriate to consider an increase in these two uncertainties when the core flow is reduced. The amount of increase is determined in a conservative way. For both parameters it is assumed that the absolute uncertainty remains the same as the flow is decreased so that the percentage uncertainty increases inversely proportional to the change in core flow. This is conservative relative to the core flow uncertainty since the variability in the absolute flow is expected to decrease somewhat as the flow decreases. For the random effective TIP uncertainty, there is no reason to believe that the percentage uncertainty should increase as the core flow decreases for TLO.
Historically, these values have been construed to be somewhat dependent on the core flow conditions as demonstrated by the fact that higher values have always been used when performing SLO calculations. It is for this reason that GNF determined that it is appropriate to consider an increase in these two uncertainties when the core flow is reduced. The amount of increase is determined in a conservative way. For both parameters it is assumed that the absolute uncertainty remains the same as the flow is decreased so that the percentage uncertainty increases inversely proportional to the change in core flow. This is conservative relative to the core flow uncertainty since the variability in the absolute flow is expected to decrease somewhat as the flow decreases. For the random effective TIP uncertainty, there is no reason to believe that the percentage uncertainty should increase as the core flow decreases for TLO.
Nevertheless, this uncertainty is also increased as is done in the more extreme case for SLO primarily to preserve the historical precedent established by the SLO evaluation. Note that the TLO condition is different than the SLO condition because for TLO there is no expected tilting of the core radial power shape.
Nevertheless, this uncertainty is also increased as is done in the more extreme case for SLO primarily to preserve the historical precedent established by the SLO evaluation. Note that the TLO condition is different than the SLO condition because for TLO there is no expected tilting of the core radial power shape.
The treatment of the core flow and random effective TIP reading uncertainties is based on the assumption that the signal to noise ratio deteriorates as core flow is reduced. GNF believes this is conservative and may in the future provide justification that the original uncertainties (non-flow dependent) are adequately bounding.
The treatment of the core flow and random effective TIP reading uncertainties is based on the assumption that the signal to noise ratio deteriorates as core flow is reduced. GNF believes this is conservative and may in the future provide justification that the original uncertainties (non-flow dependent) are adequately bounding.
The core flow and random TIP reading uncertainties used in the SLO minimum core flow SLMCPR analysis remain the same as in the rated core flow SLO SLMCPR analysis because these uncertainties (which are substantially larger than used in the TLO analysis) already account for the effects of operating at reduced core flow.
The core flow and random TIP reading uncertainties used in the SLO minimum core flow SLMCPR analysis remain the same as in the rated core flow SLO SLMCPR analysis because these uncertainties (which are substantially larger than used in the TLO analysis) already account for the effects of operating at reduced core flow.
2.2.3.       Reactor Pressure Measurement The input for reactor pressure measurement uncertainty was changed from [[131]] to [[I31]]]. Hope Creek supplied this conservative value to be used in the GNF SLMCPR analysis.
2.2.3.
Reactor Pressure Measurement The input for reactor pressure measurement uncertainty was changed from ((131)) to ((I31))]. Hope Creek supplied this conservative value to be used in the GNF SLMCPR analysis.
2.3. Departure from NRC-Approved Methodology No departures from NRC-approved methodologies were used in the Hope Creek Cycle 15 SLMCPR calculations.
2.3. Departure from NRC-Approved Methodology No departures from NRC-approved methodologies were used in the Hope Creek Cycle 15 SLMCPR calculations.
NRC-approved methodologies or methodologies that produce a conservative result (less margin to acceptance limits) were used in the Hope Creek Cycle 15 SLMCPR calculations.
NRC-approved methodologies or methodologies that produce a conservative result (less margin to acceptance limits) were used in the Hope Creek Cycle 15 SLMCPR calculations.
Discussion                                                                             Page 6 of 21
Discussion Page 6 of 21


GNF NON-PROPRIETARY INFORMATION Class I                   GNF S-0000-0068-2643 GNF Attachment 2.4. Fuel Axial Power Shape Penalty At this time, GNF has determined that higher uncertainties and non-conservative biases in the GEXL correlations for the various types of axial power shapes (i.e., inlet, cosine, outlet and double hump) could potentially exist relative to the NRC-approved methodology values, see References 3, 6, and 7. The following table identifies, by marking with an "X", this potential for each GNF product line currently being offered:
GNF NON-PROPRIETARY INFORMATION Class I GNF S-0000-0068-2643 GNF Attachment 2.4. Fuel Axial Power Shape Penalty At this time, GNF has determined that higher uncertainties and non-conservative biases in the GEXL correlations for the various types of axial power shapes (i.e., inlet, cosine, outlet and double hump) could potentially exist relative to the NRC-approved methodology values, see References 3, 6, and 7. The following table identifies, by marking with an "X", this potential for each GNF product line currently being offered:
[[
((
I                                     t I -i ]
I t
I -i ]
Axial bundle power shapes corresponding to the limiting SLMCPR control blade patterns are determined using the PANACEA 3D core simulator. These axial power shapes are classified in accordance to the following table:
Axial bundle power shapes corresponding to the limiting SLMCPR control blade patterns are determined using the PANACEA 3D core simulator. These axial power shapes are classified in accordance to the following table:
[[
((
13111 If the limiting bundles in the SLMCPR calculation exhibit an axial power shape identified by this table, GNF penalizes the GEXL critical power uncertainties to conservatively account for the impact of the axial power shape. Table 6 provides a list of the GEXL critical power uncertainties determined in accordance to the NRC-approved methodology contained in NEDE-240 11-P-A along with values actually used.
13111 If the limiting bundles in the SLMCPR calculation exhibit an axial power shape identified by this table, GNF penalizes the GEXL critical power uncertainties to conservatively account for the impact of the axial power shape. Table 6 provides a list of the GEXL critical power uncertainties determined in accordance to the NRC-approved methodology contained in NEDE-240 11-P-A along with values actually used.
For the limiting bundles, the fuel axial power shapes in the SLMCPR analysis were examined to determine the presence of axial power shapes identified in the above table. These power shapes were not found; therefore, no power shape penalties were applied to the calculated Hope Creek Cycle 15 SLMCPR values.
For the limiting bundles, the fuel axial power shapes in the SLMCPR analysis were examined to determine the presence of axial power shapes identified in the above table. These power shapes were not found; therefore, no power shape penalties were applied to the calculated Hope Creek Cycle 15 SLMCPR values.
Discussion                                                                           Page 7 of 21
Discussion Page 7 of 21


GNF NON-PROPRIETARY INFORMATION Class I                 GNF S-0000-0068-2643 GNF Attachment 2.5. Methodology Restrictions The four restrictions identified on Page 3 of NRC's Safety Evaluation relating to the General Electric Licensing Topical Reports NEDC-32601P, NEDC-32694P, and Amendment 25 to NEDE-240 11-P-A (March 11, 1999) are addressed in References 1, 2, and 3.
GNF NON-PROPRIETARY INFORMATION Class I GNF S-0000-0068-2643 GNF Attachment 2.5. Methodology Restrictions The four restrictions identified on Page 3 of NRC's Safety Evaluation relating to the General Electric Licensing Topical Reports NEDC-32601P, NEDC-32694P, and Amendment 25 to NEDE-240 11-P-A (March 11, 1999) are addressed in References 1, 2, and 3.
No new GNF fuel designs are being introduced in Hope Creek Cycle 15; therefore, the NEDC-32505-P-A statement "...if new fuel is introducted, GENE must confirm that the revised R-Factor method is still valid based on new test data" is not applicable.
No new GNF fuel designs are being introduced in Hope Creek Cycle 15; therefore, the NEDC-32505-P-A statement "...if new fuel is introducted, GENE must confirm that the revised R-Factor method is still valid based on new test data" is not applicable.
2.6. Minimum Core Flow Condition For Hope Creek Cycle 15 the minimum core flow SLMCPR calculation performed at 94.8% core flow at rated core power condition was not limiting as compared to the rated core flow at rated core power condition.
2.6. Minimum Core Flow Condition For Hope Creek Cycle 15 the minimum core flow SLMCPR calculation performed at 94.8% core flow at rated core power condition was not limiting as compared to the rated core flow at rated core power condition.
Line 76: Line 129:
2.10. Core Loading Diagram Figures 1 and 2 provide the core loading diagram for the current and previous cycle respectively, which are the Reference Loading Pattern as defined by NEDE-2401 1-P-A. Table I provides a description of the core.
2.10. Core Loading Diagram Figures 1 and 2 provide the core loading diagram for the current and previous cycle respectively, which are the Reference Loading Pattern as defined by NEDE-2401 1-P-A. Table I provides a description of the core.
2.11. Figure References Figure 3 is Figure 4.1 from NEDC-32601-P-A. Figure 4 is Figure 111.5-1 from NEDC-32601P-A. Figure 5 is Figure 111.5-2 from NEDC-32601P-A.
2.11. Figure References Figure 3 is Figure 4.1 from NEDC-32601-P-A. Figure 4 is Figure 111.5-1 from NEDC-32601P-A. Figure 5 is Figure 111.5-2 from NEDC-32601P-A.
Discussion                                                                           Page 8 of 21
Discussion Page 8 of 21


GNF NON-PROPRIETARY INFORMATION Class I                   GNF S-0000-0068-2643 GNF Attachment 2.12. Additional SLMCPR Licensing Conditions Hope Creek has submitted a licensing amendment to increase rated power from 3339 MWt to 3840 MWt, which is reflected in the attached power/flow map. This uprate licensing amendment is currently being reviewed by the NRC with anticipation of approval before Hope Creek Cycle 15 starts up. Recent NRC communications for such uprates have suggested that an 0.02 adder to the SLMCPR will be a licensing condition. In anticipation that this licensing condition will be imposed on the Hope Creek uprate amendment, the SLMCPR has been established by adding 0.02 to the cycle-specific SLMCPR value calculated using the NRC-approved methodologies documented in NEDE-2401 1-P-A (see Table 3).
GNF NON-PROPRIETARY INFORMATION Class I GNF S-0000-0068-2643 GNF Attachment 2.12. Additional SLMCPR Licensing Conditions Hope Creek has submitted a licensing amendment to increase rated power from 3339 MWt to 3840 MWt, which is reflected in the attached power/flow map. This uprate licensing amendment is currently being reviewed by the NRC with anticipation of approval before Hope Creek Cycle 15 starts up. Recent NRC communications for such uprates have suggested that an 0.02 adder to the SLMCPR will be a licensing condition. In anticipation that this licensing condition will be imposed on the Hope Creek uprate amendment, the SLMCPR has been established by adding 0.02 to the cycle-specific SLMCPR value calculated using the NRC-approved methodologies documented in NEDE-2401 1-P-A (see Table 3).
2.13. Summary The requested changes to the Technical Specification SLMCPR values are 1.08 for TLO and 1.10 for SLO for Hope Creek Cycle 15.
2.13. Summary The requested changes to the Technical Specification SLMCPR values are 1.08 for TLO and 1.10 for SLO for Hope Creek Cycle 15.
Discussion                                                                         Page 9 of 21
Discussion Page 9 of 21


GNF NON-PROPRIETARY INFORMATION Class I                   GNF S-0000-0068-2643 GNF Attachment 3.0 References
GNF NON-PROPRIETARY INFORMATION Class I GNF S-0000-0068-2643 GNF Attachment 3.0 References
: 1. Letter, Glen A. Watford (GNF-A) to U.S. Nuclear Regulatory Commission Document Control Desk with attention to R. Pulsifer (NRC), "Confirmation of 10xl0 Fuel Design Applicability to Improved SLMCPR, Power Distribution and R-Factor Methodologies",
: 1. Letter, Glen A. Watford (GNF-A) to U.S. Nuclear Regulatory Commission Document Control Desk with attention to R. Pulsifer (NRC), "Confirmation of 10xl0 Fuel Design Applicability to Improved SLMCPR, Power Distribution and R-Factor Methodologies",
FLN-2001-016, September 24, 2001.
FLN-2001-016, September 24, 2001.
Line 92: Line 145:
Proprietary Slides - July 31 - August 1, 2002", FLN-2002-015, October 31, 2002.
Proprietary Slides - July 31 - August 1, 2002", FLN-2002-015, October 31, 2002.
: 7. Letter, Jens G. Munthe Andersen (GNF-A) to U.S. Nuclear Regulatory Commission Document Control Desk with attention to Alan Wang (NRC), "GEXL Correlation for 1OX10 Fuel", FLN-2003-005, May 31, 2003.
: 7. Letter, Jens G. Munthe Andersen (GNF-A) to U.S. Nuclear Regulatory Commission Document Control Desk with attention to Alan Wang (NRC), "GEXL Correlation for 1OX10 Fuel", FLN-2003-005, May 31, 2003.
References                                                                       Page 10 of 21
References Page 10 of 21


GNF NON-PROPRIETARY INFORMATION Class I                           GNF S-0000-0068-2643 GNF Attachment Figure 1. Current Cycle Core Loading Diagram 58f]
GNF NON-PROPRIETARY INFORMATION Class I GNF S-0000-0068-2643 GNF Attachment Figure 1. Current Cycle Core Loading Diagram 58 EM&0F M
58                              l [0 [K] Mr~S [E]"tM EM&0F  [0 [flM10*"
M E
                                                                  *[ ID
58f]
                                                                    ]*J[10M      RM101 M []   E 54                         W.W+.           E+rg 1FR+i A RWv+ i 52                   C[[Ei] 3 -lI1T flF11                   -e [i-eF2! 10[ I11 [] ff 1E 10 11iI*I1@ENDMil
l [0 [K] Mr~S [E]"tM [0 [fl
                                                                      -id       17'YE U         -
*[
50-       []0]t ICPI ]_L][]M rfr[@E-3d       r[ [EC E]_   - 17]r[]_LI ] [][ E7[]   E'_[E_7 r[-0 H]i['r*[-! ]     []TN N  [] ]*1 j2---L*   FE]jE@E]_I]
M ]*J[
IgT[-E gjg E7] M]rjlIQ_3S       M7[g N] []o   EMI             _ MlZ T]E]M] [][],        M[] E]
10*"
_p[Q[E 91_]MHD    ] ] [911   91 [E   RE] M] El M] ML~S m_g3-                         _L -L 8 1-1 mm1E-       '' MR,]NO MR           []] 1% I15 NO1*-Lr       I M *rm[,
ID 10
MI M-'II*M MM            MIM MI**1
[]
                                                                                                    ]I**         F nm-1 16      -      9i11II      1j0flfl[[          EEI[II 0 00009            1II11101J0R]-AN 8i----EUF11T~f T                            10        EO[I            O                            11 SoE1-P[l~g[IV0CAB402-G6.0/16@G4.-100T~- 15-jT6--275             M=GE14-PI 0CNAB393[-@8GZr-100- 150-T6-2884L 8 PrK     l 10NB2-5G6.0 L 27G4.-100T             -2758   N=GE[14-P           legCNAB 39-17         0T- 150-T6-3008 2F=GE                                        115-T6PI1        2 OGE 14- 10CNB40014GZ G=SVA9-N1       POF1ELR    1CASL 36-1G50-68-4R             150-T6265                                               1100T-15-630 H=SEA6-POCSB61-4G-56U-WR 150-T6-2658                             RI1 1 3 5 1 0 11If15517 19 21 23 25 27 29 31 333S3755719                       1 1315 47 ig51 55 5557595 Fuel Type A=SVEA96-P1OCASB36O-12GZ-568U-4WvR-15O-T6-2656                   I= same as D B=SVEA96-PI OCASB36O- 12G5.O-568U-4WvR- 150-T6-2657             J=GE 14-P IOCNAB396-1I7GZ- lOOT-I 50-T6-3007 C=SVEA96-P IOCASB36 1-14GZ-568U-4WvR- 150-T6-2658               K=GE 14-P 1OCNAB393- 18G4.O- 1OOT- 150-T6-2885 D=SVEA96-P IOCASB36O- 12G5.5/2G2.5-568U-4WvR- 150-T6-2659       L--GEI 4-P1 OCNAB4O5-L5GZ- IOOT-1 50-T6-3009 E--GE 14-PI1OCNAB4O2-4G6.O/1 6G4.O- lOOT- 150-T6-2757           M=GE14-P IOCNAB393- 18GZ-I1OOT- 150-T6-2884 F=GE 14-PI1OCNAB4O2-5G6.O/1 4G4.O- lOOT- 150-T6-2758             N=GE1 4-P 1OCNAB398-1I7GZ-I1OOT- 150-T6-3008 G--SVEA96-P IOCASB36O- 12G5.O-568U-4WR- 150-T6-2657             O=GE 14-P 1OCNAB400- l4GZ-I1OOT- 150-T6-3006 H=SVEA96-P1 OCASB36I -14GZ-568U-4WvR- 150-T6-2658 Figure 1. Current Cycle Core Loading Diagram                                                                 Page I I of 21
RM101 54 W. W+.
E+
rg 1 FR+i A RWv+ i 52 C[ [E i] 3 -lI1T flF11 -e
[i-e F2! 10[ I11 [] ff 1E 1 0 I1@ENDMil  
-id 11iI*
17'YE U
50-CPI
[]0]t I
]_L][]M rf r[@E-3d r[
E]_ -
[EC 17] r[]_LI [
] [] E7[]
E'_
[E_7 r[-0 [
H]i'r*[-! ]
[]T [] *1 N
]
N j2--- L*
FE]jE I
@E]_I]
gT[-E gjg E7] M]rjlIQ_3S M7[g N] []o EMI MlZ T]E] M] M[] E]
[][],
_p[ Q[E _]
91
]
M ]
HD
[911 91 [E RE] M] El M] ML~S m_g3-
_L  
-L 8
1-1 mm1 E-
[))
MR,] NO MR 1%
15 NO1*-Lr M  
-'II* ]I**
I M M I
M M I
M M I M M I**1 F nm -1  
*rm[,
SoE1-P[l~g[IV 0CAB402-G6.0/16@G4.-100T~- 15-jT6--275 M=GE14-PI 0CNAB393[-@ 8GZr-100- 150 -T6-2884L 2F=GE 14-PrK l
10NB2-5G6.0 27G4.-100T 15-T6PI
-2758 N=GE[ 14-P legCNAB 39-17 0T-150-T6-3008 G=SVA9-P N1 OF1ELR L
1CAS 36-1G50-68-4R 150-T6265 OGE 14-10CNB40014GZ 1100T-15-630 H=SEA6-POCSB61-4G-56U-WR 150-T6-2658 RI1 16 9i11II 1j0flfl((
EEI[II 0 00009 1II11101J0R]-AN 8i----EUF11T~f 10 EO[I O
T 11 8 -
L 1
1 2
1 3 5 1 0 11If15517 19 21 23 25 27 29 31 333S3755719 1 1315 47 ig51 55 5557595 Fuel Type A=SVEA96-P1OCASB36O-12GZ-568U-4WvR-15O-T6-2656 I= same as D B=SVEA96-PI OCASB36O-12G5.O-568U-4WvR-150-T6-2657 J=GE 14-P IOCNAB396-1I7GZ-lOOT-I 50-T6-3007 C=SVEA96-P IOCASB36 1-14GZ-568U-4WvR-150-T6-2658 K=GE 14-P 1OCNAB393-18G4.O-1OOT-150-T6-2885 D=SVEA96-P IOCASB36O-12G5.5/2G2.5-568U-4WvR-150-T6-2659 L--GEI 4-P1 OCNAB4O5-L5GZ-IOOT-1 50-T6-3009 E--GE 14-PI1OCNAB4O2-4G6.O/1 6G4.O-lOOT-150-T6-2757 M=GE14-P IOCNAB393-18GZ-I1OOT-150-T6-2884 F=GE 14-PI1OCNAB4O2-5G6.O/1 4G4.O-lOOT-150-T6-2758 N=GE1 4-P 1OCNAB398-1I7GZ-I1OOT-150-T6-3008 G--SVEA96-P IOCASB36O-12G5.O-568U-4WR-150-T6-2657 O=GE 14-P 1OCNAB400- l4GZ-I1OOT-150-T6-3006 H=SVEA96-P1 OCASB36I -1 4GZ-568U-4WvR-150-T6-2658 Figure 1. Current Cycle Core Loading Diagram Page I I of 21


GNF NON-PROPRIETARY INFORMATION Class I                               GNF S-0000-0068-2643 GNF Attachment Figure 2. Previous Cycle Core Loading Diagram 60                                         E_L[D [D]_EA]         A] [A] E] []_   [A]_[A   [A] [
GNF NON-PROPRIETARY INFORMATION Class I GNF S-0000-0068-2643 GNF Attachment Figure 2. Previous Cycle Core Loading Diagram 60 E_L[D [D]_EA ]
58                                         El FI   EIFI [ [                   E]l []ED E F-56 54 E[A]     E]
A] [A] E] []_
BFB F C1E
[A]_[A
[E]rj_0 E_*W       [EE][D [DH[ [H]__E] [B]+ E] [] [D [D [f El 52                   EA~] [E] [E]F] [E]i-fl_1___[E] E] [E][]E]] *_[DE       [E] L_1] [E]
[A] [
EI]ED] [E] [Q]
58 El FI EIFI [ [
50                         W El~~~~~~~
E]l []ED E F-56 E[A] E]
                                            -~ 0IE j iWEE
[E]rj_0 E_*W
                                                              ~~                  M E D -L- E mM]I]                           E EiE
[EE]
                                                                                                                        -El      lE 46                                          [DIE) EW[]JI               E]] E]EEEE 44 44          E] E]   [] [E] []   [J] [E] IT]L[][I[E F*iJLc--]   [E] E]]  [EJ]
[D [DH[  
i-1*ii -clE[ ] [E]     0
+
[] E   E'c"I__l" E'B-10 E-I 3A*ID BIRIIE]   IB                      MID 40     [A]IEE] E__FGJ   EE]F]E[] E] [E] E] [A] [J] [1] [CD EC] ED]_lr- [AZ]Ec]F[J] [B]
[H]__E] [B] E] [] [D [D [f 54 BF B F C1E El 52 EA~]
[CD                                                                                C]     E]IFC_2F FICE 34               MAFW I'M ] NE [C IE)            J_B [DWE"R0LEI[
[E] [E]F] [E] i-fl_1___ [E] E] [E][] E)) *_ [DE
[DIE]                              COF -    D         B     []MC]           I L- El  A-IE]
[E]
30                                                                C B ] B ] C[ JD MD      C] C] JE][E]
L_1] [E] EI]
                  ] [E] [E-- [] [] [] [A] E]-I -l DI- IDW]IE 0E1EDWE]][                     J] [C]
ED] [E] [Q]
R B] E]         11E n   C-I]           [E]       l- -A 32     EA[E]*- E__]I-] E] E[E] E]     [] r]M _LE]- E]-
50 W  
EDL[]   E] []] [E]*I-f E iT_*-   [B]
~
EC] E]           [DDEL] E]E]*-
j
[]                  QLrll-26 30     EDM]8XMEW ]E]                      *I1 9[DI]0   F0MINEJ        D]ME] PIWIMIE              ]J--E []    D IFEe [Ell- -l
- 0IE
                  *6[] FIILE] [][] [ _]E]_E] FI__F                   [] [D E]IJE] I_[D-   [D_12F-I[D[D               J]E Ell [D EIjI]     E 22  B              F          C    BF  ~      5      I            ~ HO        A FC        D BJC CF 28 18      E][EEAI[E]
-L-E EiE lE El~~~~~~~  
FEBl E-F  C
~~
[DE EJ]
-El M E D iWEE mM]I] E 46
I5E]  EC ] E]][D[  Ii- ]L*-
[DIE) EW[] JI E)) E]EEEE 44 E]
CIE  B ONE]j~    E-TE M70WN E_L*[D         ElF Ellr-
E]
[]
[E] []
[J] [E] IT]L[][I[E F*iJLc--]
[E] E)) [EJ]
i-1*ii -clE[ ] [E]
[]
0 E
E'c"I__l" E'B-10 E-I 44 3A*ID IB MID BIRIIE]
40
[A]IEE] E__FGJ
[CD EE] F] E[] E] [E] E] [A] [J] [1] [CD EC] ED]_lr- [AZ] Ec]
F[J] [B] C]
E]IF C_2F FIC E
34 A FW
]
M
[D C J_
B COF D
B
[]M C]
A-IE]
I'M NE [
IE)
[DIE]
WE"R0LEI[
I L-El 30
] [E] [E-- [] [] [] [A] E]-I -l J] [C]
C
]
B
]
B JD MD E]
C[
[E]
B] C] C] JE] C-
-A DI-IDW]IE 0E1EDWE))[ R 11E n I]
[E]
l-32 EA
[E]*-
E__]I-] E] E[E] E]
[] _LE]- E]- L[] E] [] ] [E]*I-f E iT_*-
[B]
EC]
E]
[]
[DDEL] E] E]*-
QLrll-30 EDM]8XME
*I1 9[DI]0 D]ME]
WIMIE D IFEe [Ell- -l
*6 [] FIILE] [][]
_]
[
E]_ E] FI__F
[] [D E]IJE] I_[D-
[D_12F-I [D [D J] E Ell [D EIjI]
E 28 E][EEAI[E] [DE EJ]
EC Ii-  
]
]L*-
E)) [D[
ElF Ellr-
_L*[D
[]l[
[]l[
l WEIJ E           AA 122     5IE 7DEERI 11   W1315        19 E1723,2 252E%1    2   1   3353     3       1   454F2`3         53 1
26 r]M W ]E] ED F0MINEJ J--E PI ]
                                                                                                                              `4       L!575 10DOM FuE] MyE           ENE-           [1EPEElPIEF]
[]
A=SVEA96-P 10CASB360- 12GZ-568U-4WR- 150-T6-2656 (Cycle 11)                           I=SVEA96-P IOCASB360- 12G5.5/2G2.5-568U B=SVEA96-PIOCASB360-12G5.0-568U-4WR-150-T6-2657 (Cycle 11)                               -4WR-150-T6-2659 (Cycle 12)
122 5IE 7DE ERI 11 W13 15 E17 19 E%1 23,2 252 2
C=SVEA96-PI OCASB36                     I 14GZ-568U-4WR-             I50-T6-2658 (Cycle 12)       J=GEI4-P1CNAB393-18G4.0-T-150-T6-2885(Cycle 14)
1 3353 3
D=SVEA96-P10OCASB360-1I2G5.5/2G2.5-568U-4WR- 150-T6-2659 (C 12)                       K=GEI14-P IOCNAB393- 18GZ-100OT- 150-T6-2884 (Cycle 14)
1 F2`3 454
`4 1
53 L!575 FuE] MyE ENE-
[1EPEElPIEF]
22 B F
C BF ~
5 I
~
FC HO D
A CF J
B C
18 Bl FE C
E-F I5E]
B CIE ONE]j~
E-TE M70WN E l WEIJ E AA 10DOM A=SVEA96-P 10CASB360- 12GZ-568U-4WR-150-T6-2656 (Cycle 11)
I=SVEA96-P IOCASB360- 12G5.5/2G2.5-568U B=SVEA96-PIOCASB360-12G5.0-568U-4WR-150-T6-2657 (Cycle 11)  
-4WR-150-T6-2659 (Cycle 12)
C=SVEA96-PI OCASB36 I
14GZ-568U-4WR-I50-T6-2658 (Cycle 12)
J=GEI4-P1CNAB393-18G4.0-T-150-T6-2885(Cycle 14)
D=SVEA96-P10OCASB360-1I2G5.5/2G2.5-568U-4WR-150-T6-2659 (C 12)
K=GEI14-P IOCNAB393-18GZ-100OT-150-T6-2884 (Cycle 14)
E=GEI 4-P 10OCNAB402-4G6.0/1 6G4.O-100OT-1 50-T6-2757 (Cycle 13 )
E=GEI 4-P 10OCNAB402-4G6.0/1 6G4.O-100OT-1 50-T6-2757 (Cycle 13 )
F=GEI14-PI1OCNAB402-5G6.0/14G4.0- l00T- 150-T6-2758 (Cycle 13)
F=GEI14-PI1OCNAB402-5G6.0/14G4.0- l00T-150-T6-2758 (Cycle 13)
G=SVEA96-P I 0CASB360- 12G5.0-568U-4WR- 150-T6-2657 (Cycle 11 )
G=SVEA96-P I 0CASB360- 12G5.0-568U-4WR-150-T6-2657 (Cycle 11 )
H=SVEA96-P10OCASB361 -14GZ-568U-4WR- 150-T6-2658 (Cycle 12)
H=SVEA96-P10OCASB361 -14GZ-568U-4WR-150-T6-2658 (Cycle 12)
Figure 2. Previous Cycle Core Loading Diagram                                                                               Pacre1-1 12 of 21
Figure 2. Previous Cycle Core Loading Diagram Pacre 12 of 21 1-1


GNF NON-PROPRIETARY INFORMATION Class I           GNF S-0000-0068-2643 GNF Attachment Figure 3. Figure 4.1 from NEDC-32601-P-A
GNF NON-PROPRIETARY INFORMATION Class I GNF S-0000-0068-2643 GNF Attachment Figure 3. Figure 4.1 from NEDC-32601-P-A
[[131]]
((131))
Figure 4. Figure 111.5-1 from NEDC-32601P-A
Figure 4. Figure 111.5-1 from NEDC-32601P-A
[[131]]
((131))
Figure 5. Figure 111.5-2 from NEDC-32601P-A
Figure 5. Figure 111.5-2 from NEDC-32601P-A
[[ 131]]
(( 131))
Figure 3. Figure 4.1 from NEDC-32601-P-A                           Page 13 of 21
Figure 3. Figure 4.1 from NEDC-32601-P-A Page 13 of 21


GNF Non-Proprietary Information Class I                       GNF S-0000-0068-2643 GNF Attachment Table 1. Desclription of Core Previous Cycle         Previous Cycle Rated         Current Cycle Current Cycle Rated Description             Minimum Core Flow           Core Flow Limiting     Minimum Core Flow Core Flow Limiting Limiting Case                 Case                 Limiting Case       Case Number of Bundles in the                       764                     764                     764             764 Core Limiting Cycle Exposure Point (i.e.                                   BOC                     BOC                     EOC             EOC BOC/MOC/EOC)
GNF Non-Proprietary Information Class I GNF S-0000-0068-2643 GNF Attachment Table 1. Desclription of Core Previous Cycle Previous Cycle Rated Current Cycle Current Cycle Rated Description Minimum Core Flow Core Flow Limiting Minimum Core Flow Core Flow Limiting Limiting Case Case Limiting Case Case Number of Bundles in the 764 764 764 764 Core Limiting Cycle Exposure Point (i.e.
Cycle Exposure at Limiting Point                                 200                     200                     11000           11000 (MWd/STU)
BOC BOC EOC EOC BOC/MOC/EOC)
    % Rated Core Flow                           76.6*                     100                     94.8*             100 Reload Fuel Type                             GE14                     GE14                     GEl4             GEl4 Latest Reload Batch                           20.4                     20.4                     29.8             29.8 Fraction, %
Cycle Exposure at Limiting Point 200 200 11000 11000 (MWd/STU)
Latest Reload Average Batch Weight %                               3.93                     3.93                   4.00             4.00 Enrichment Core Fuel Fraction, %:
% Rated Core Flow 76.6*
GE14                                         41.9                     41.9                     71.7             71.7 SVEA96                                       58.1                     58.1                     28.3             28.3 Core Average Weight %                         3.76                     3.76                     3.88             3.88 Enrichment
100 94.8*
100 Reload Fuel Type GE14 GE14 GEl4 GEl4 Latest Reload Batch 20.4 20.4 29.8 29.8 Fraction, %
Latest Reload Average Batch Weight %
3.93 3.93 4.00 4.00 Enrichment Core Fuel Fraction, %:
GE14 41.9 41.9 71.7 71.7 SVEA96 58.1 58.1 28.3 28.3 Core Average Weight %
3.76 3.76 3.88 3.88 Enrichment
* Refer to the Power/Flow map for lowest flow at rated power.
* Refer to the Power/Flow map for lowest flow at rated power.
Table 1. Description of Core                                                                                             Pacye L_ 14 of 21
Table 1. Description of Core Pacye 14 of 21 L_


GNF Non-Proprietary Information Class I                         GNF S-0000-0068-2643 GNF Attachment Table 2. SLMCPR Calculation Methodologies Previous Cycle     Previous Cycle Rated         Current Cycle Current Cycle Rated Description       Minimum Core Flow     Core Flow Limiting     Minimum Core Flow Core Flow Limiting Limiting Case             Case                 Limiting Case       Case Non-power Distribution       NEDC-32601P-A         NEDC-32601P-A             NEDC-32601P-A   NEDC-32601P-A Uncertainty Power Distribution           NEDC-32694P-A         NEDC-32694P-A             NEDC-32694P-A   NEDC-32694P-A Methodology Power Distribution           NEDC-32694P-A         NEDC-32694P-A             NEDC-32694P-A   NEDC-32694P-A Uncertainty Core Monitoring System       3DMONICORE           3DMONICORE               3DMONICORE       3DMONICORE Table 2. SLMCPR Calculation Methodologies                                                               Page 15 of 21
GNF Non-Proprietary Information Class I GNF S-0000-0068-2643 GNF Attachment Table 2. SLMCPR Calculation Methodologies Previous Cycle Previous Cycle Rated Current Cycle Current Cycle Rated Description Minimum Core Flow Core Flow Limiting Minimum Core Flow Core Flow Limiting Limiting Case Case Limiting Case Case Non-power Distribution NEDC-32601P-A NEDC-32601P-A NEDC-32601P-A NEDC-32601P-A Uncertainty Power Distribution NEDC-32694P-A NEDC-32694P-A NEDC-32694P-A NEDC-32694P-A Methodology Power Distribution NEDC-32694P-A NEDC-32694P-A NEDC-32694P-A NEDC-32694P-A Uncertainty Core Monitoring System 3DMONICORE 3DMONICORE 3DMONICORE 3DMONICORE Table 2. SLMCPR Calculation Methodologies Page 15 of 21


GNF Non-Proprietary Information Class I                         GNF S-0000-0068-2643 GNF Attachment Table 3. Monte Carlo Calculated SLMCPR vs. Estimate Previous Cycle     Previous Cycle Rated         Current Cycle Current Cycle Rated Description           Minimum Core Flow     Core Flow Limiting     Minimum Core Flow Core Flow Limiting Limiting Case             Case                 Limiting Case       Case
GNF Non-Proprietary Information Class I GNF S-0000-0068-2643 GNF Attachment Table 3. Monte Carlo Calculated SLMCPR vs. Estimate Previous Cycle Previous Cycle Rated Current Cycle Current Cycle Rated Description Minimum Core Flow Core Flow Limiting Minimum Core Flow Core Flow Limiting Limiting Case Case Limiting Case Case
[U 13111 Table 3. Monte Carlo Calculated SLMCPR vs. Estimate                                                     Page 16 of 21
[U 13111 Table 3. Monte Carlo Calculated SLMCPR vs. Estimate Page 16 of 21


GNF Non-Proprietary Information Class i                                 GNF S-0000-0068-2643 GNF Attachment Table 4. Non-Power Distribution Uncertainties Nominal (NRC-       Previous Cycle     Previous Cycle       Current Cycle     Current Cycle Approved) Value       Minimum Core       Rated Core Flow       Minimum Core       Rated Core Flow ca (%)       Flow Limiting Case   Limiting Case     Flow Limiting Case     Limiting Case GETAB Feedwater Mow                 1.76               N/A                 N/A                 N/A                 N/A Measurement Feedwater Temperature                   0.76               N/A                 N/A                 N/A                 N/A Measurement Reactor Mea     Pressure sure                 0.50               N/A                 N/A                 N/A                 N/A Measurement Core Inlet Temperature                   0.20               N/A                 N/A                 N/A                 N/A Measurement Total Core Flow       6.0 SLO/2.5 TLO           N/A                 N/A                 N/A                 N/A Measurement Channel Flow Area               3.0               N/A                 N/A                 N/A                 N/A Variation Friction Factor               10.0               N/A                 N/A                 N/A                 N/A Multiplier Channel Friction FactorMutipi                   5.0               N/A                 N/A                 N/A                 N/A Factor Multiplier Table 4. Non-Power Distribution Uncertainties                                                                     Page 17 of 21
GNF Non-Proprietary Information Class i GNF S-0000-0068-2643 GNF Attachment Table 4. Non-Power Distribution Uncertainties Nominal (NRC-Previous Cycle Previous Cycle Current Cycle Current Cycle Approved) Value Minimum Core Rated Core Flow Minimum Core Rated Core Flow a c (%)
Flow Limiting Case Limiting Case Flow Limiting Case Limiting Case GETAB Feedwater Mow 1.76 N/A N/A N/A N/A Measurement Feedwater Temperature 0.76 N/A N/A N/A N/A Measurement Reactor Pressure Mea sure 0.50 N/A N/A N/A N/A Measurement Core Inlet Temperature 0.20 N/A N/A N/A N/A Measurement Total Core Flow 6.0 SLO/2.5 TLO N/A N/A N/A N/A Measurement Channel Flow Area 3.0 N/A N/A N/A N/A Variation Friction Factor 10.0 N/A N/A N/A N/A Multiplier Channel Friction FactorMutipi 5.0 N/A N/A N/A N/A Factor Multiplier Table 4. Non-Power Distribution Uncertainties Page 17 of 21


GNF Non-Proprietary Information Class I                                 GNF S-0000-0068-2643 GNF Attachment Table 4. Non-Power Distribution Uncertainties Nominal (NRC-       Previous Cycle     Previous Cycle         Current Cycle     Current Cycle Approved) Value       Minimum Core     Rated Core Flow         Minimum Core       Rated Core Flow
GNF Non-Proprietary Information Class I GNF S-0000-0068-2643 GNF Attachment Table 4. Non-Power Distribution Uncertainties Nominal (NRC-Previous Cycle Previous Cycle Current Cycle Current Cycle Approved) Value Minimum Core Rated Core Flow Minimum Core Rated Core Flow
                              + g (%)       Flow Limiting Case   Limiting Case       Flow Limiting Case   Limiting Case NEDC-32601-P-A I1                 I I                   I I
+ g (%)
I                  I Table 4. Non-Power Distribution Uncertainties                                                                       Page 18 of 21
Flow Limiting Case Limiting Case Flow Limiting Case Limiting Case NEDC-32601-P-A I1 I
I I
I I
I Table 4. Non-Power Distribution Uncertainties Page 18 of 21


GNF Non-Proprietary Information Class I                                 GNF S-0000-0068-2643 GNF Attachment Table 5. Power Distribution Uncertainties Nominal (NRC-     Previous Cycle       Previous Cycle       Current Cycle       Current Cycle Description       Approved) Value     Minimum Core       Rated Core Flow       Minimum Core       Rated Core Flow
GNF Non-Proprietary Information Class I GNF S-0000-0068-2643 GNF Attachment Table 5. Power Distribution Uncertainties Nominal (NRC-Previous Cycle Previous Cycle Current Cycle Current Cycle Description Approved) Value Minimum Core Rated Core Flow Minimum Core Rated Core Flow
                                +/- * (%)     Flow Limiting Case     Limiting Case     Flow LiMiting Case     Limiting Case GETAB/NEDC-32601-P-A GEXL R-Factor                 [E {3)]           N/A                   N/A                 N/A                   N/A Random Effective       2.85 SLO/1.2 TLO         N/A                   N/A                 N/A                   N/A TIP Reading Systematic Effective             8.6             N/A                   N/A                 N/A                   N/A TIP Reading NEDC-32694-P-A, 3DMONICORE GEXL R-Factor                 [[ 313]]          [[                    E[                      "3)]]
+/- * (%)
[[(3)]]              [[
Flow Limiting Case Limiting Case Flow LiMiting Case Limiting Case GETAB/NEDC-32601-P-A GEXL R-Factor
[3)]] 131]]
[E {3)]
Random Effective       2.85 SLO/1.2 TLO   2.85 SLO/1.2 TLO     2.85 SLO/1.2 TLO     2.85 SLO/1.2 TLO     2.85 SLO/I.2 TLO TIP Reading TIP Integral                                     E[ 131]               [[(3)]]
N/A N/A N/A N/A Random Effective 2.85 SLO/1.2 TLO N/A N/A N/A N/A TIP Reading Systematic Effective 8.6 N/A N/A N/A N/A TIP Reading NEDC-32694-P-A, 3DMONICORE GEXL R-Factor
1311]            E1                  [[ {31]] ]3]]]
(( 313))
Four Bundle Power Distribution                     131]j Surrounding TIP                   3]           [[ (3{]]                      ]            [   3}][3]]
((
Location Contribution to B undle Pow er                                       "I]]                  "I]]                131]j                   "I]]
"3)))
Uncertainty Due to LPRM Update Table 5. Power Distribution Uncertainties                                                                             Page 19 of 21
E[
[3)))
(((3)))
((
131))
Random Effective 2.85 SLO/1.2 TLO 2.85 SLO/1.2 TLO 2.85 SLO/1.2 TLO 2.85 SLO/1.2 TLO 2.85 SLO/I.2 TLO TIP Reading TIP Integral 1 311]
E[ 131]
(((3)))
E1
]3))]
(( {31))
Four Bundle Power Distribution 131]j Surrounding TIP 3]
(( (3{))
]
[
3}][3))
Location Contribution to B undle Pow er "I))
"I))
131]j "I))
Uncertainty Due to LPRM Update Table 5. Power Distribution Uncertainties Page 19 of 21


GNF Non-Proprietary Information Class I                                 GNF S-0000-0068-2643 GNF Attachment Table 5. Power Distribution Uncertainties Nominal (NRC-       Previous Cycle       Previous Cycle       Current Cycle         Current Cycle Description       Approved) Value     Minimum Core         Rated Core Flow       Minimum Core         Rated Core Flow ag (%)   Flow Limiting Case     Limiting Case     Flow Limiting Case       Limiting Case Contribution to Bundle Power Due to         [[  {3}]]          [[ {3}]]              [[{3}]]                      [[{3]3]
GNF Non-Proprietary Information Class I GNF S-0000-0068-2643 GNF Attachment Table 5. Power Distribution Uncertainties Nominal (NRC-Previous Cycle Previous Cycle Current Cycle Current Cycle Description Approved) Value Minimum Core Rated Core Flow Minimum Core Rated Core Flow a
Failed TIP Contribution to Bundle Power Due to         [[  {3}]]          [[ (3)]]              [[13)1]             [[{31]]              [[(3)]]
g (%)
Failed LPRM Total Uncertainty in Calculated Bundle           [[ 131]]            [[(3)]]                [[3T]]              [[131]]              [[]3)]
Flow Limiting Case Limiting Case Flow Limiting Case Limiting Case Contribution to Bundle Power Due to
Power Uncertainty of TIP                                                                                                   3 3                  3 Signal Nodal                 E[ 13)]]          E[ {31]]              E13                [iE }]]
(( {3}))
                                                                                                    ]]]                ([E)]]
(( {3}))
Uncertainty Table 5. Power Distribution Uncertainties                                                                             Page 20 of 21
(({3}))
(({3]3]
Failed TIP Contribution to Bundle Power Due to
(( {3}))
(( (3)))
((13)1]
(({31))
(((3)))
Failed LPRM Total Uncertainty in Calculated Bundle
(( 131))
(((3)))
((3T))
((131))
((]3)]
Power Uncertainty of TIP Signal Nodal E[ 13)))
E[
{31))
E13 3
))]
[iE 3}))
([E 3 )))
Uncertainty Table 5. Power Distribution Uncertainties Page 20 of 21


GNF Non-Proprietary Information Class I                                 GNF S-0000-0068-2643 GNF Attachment Table 6. Critical Power Uncertainties Description TNominal Value   Previous Cycle Minimum Core Previous Cycle Rated Core Flow Current Cycle Minimum Core Current Cycle Rated Core Flow
GNF Non-Proprietary Information Class I GNF S-0000-0068-2643 GNF Attachment Table 6. Critical Power Uncertainties T
                                +/- o(%)   Flow Limiting Case     Limiting Case     Flow Limiting Case   Limiting Case 131]]
Value Previous Cycle Previous Cycle Current Cycle Current Cycle Description Nominal Minimum Core Rated Core Flow Minimum Core Rated Core Flow
Table 6. Critical Power Uncertainties                                                                           Page 21 of 21}}
+/- o (%)
Flow Limiting Case Limiting Case Flow Limiting Case Limiting Case 131))
Table 6. Critical Power Uncertainties Page 21 of 21}}

Latest revision as of 22:05, 14 January 2025

GNF S-0000-0068-2643, GNF Additional Information Regarding the Requested Changes to the Technical Specification Slmcpr. Hope Creek (KT1) Cycle 15
ML072480572
Person / Time
Site: Hope Creek PSEG icon.png
Issue date: 06/15/2007
From:
Global Nuclear Fuel
To:
Office of Nuclear Reactor Regulation
References
LCR H05-01, Rev 1, LR-N07-0215 GNF S-0000-0068-2643
Download: ML072480572 (22)


Text

ATTACHMENT 3 Hope Creek Generating Station Facility Operating License No. NPF-57 NRC Docket No. 50-354 Extended Power Uprate GNF Hope Creek C15 SLMCPR - Non-Proprietary Letter

GNF NON-PROPRIETARY INFORMATION Class I GNF S-0000-0068-2643 GNF Attachment 6/15/2007 GNF S-0000-0068-2643 GNF Additional Information Regarding the Requested Changes to the Technical Specification SLMCPR Hope Creek (KT1) Cycle 15 Hope Creek (KT1) Cycle 15 Page 1 of 21

GNF NON-PROPRIETARY INFORMATION Class I GNF S-0000-0068-2643 GNF Attachment Proprietary Information Notice This document is the GNF non-proprietary version of the GNF proprietary report. From the GNF proprietary version, the information denoted as GNF proprietary (enclosed in double brackets) was deleted to generate this version.

Proprietary Information Notice Page 2 of 21

GNF NON-PROPRIETARY INFORMATION Class I GNF S-0000-0068-2643 GNF Attachment Table of Contents 1.0 M ETH O D O LO G Y..........................................................................................................................................

4 2.0 D ISC U SSIO N...................................................................................................................................................

4 2.1.

M AJOR CONTRIBUTORS TO SLM CPR CHANGE.......................................................................................... 4 2.2.

D EVIATIONS IN N RC-APPROVED U NCERTAINTIES.....................................................................................

5 2.2.1.

R-Factor.................................................................................................................................................

5 2.2.2.

Core Flow Rate and Random Eff ective TIP Reading.......................................................................

5 2.2.3.

Reactor Pressure M easurem ent....................................................................................................

6 2.3.

D EPARTURE FROM N RC-A PPROVED M ETHODOLOGY................................................................................

6 2.4.

FUEL A XIAL POWER SHAPE PENALTY...................................................................................................

7 2.5.

M ETHODOLOGY RESTRICTIONS......................................................................................................................

8 2.6.

M IN IM UM CORE FLOW CONDITION................................................................................................................

8 2.7.

LIM ITING CONTROL ROD PATTERNS...............................................................................................................

8 2.8.

CORE M ONITORING SYSTEM..........................................................................................................................

8 2.9.

POWE R/FLOW M AP.........................................................................................................................................

8 2.10.

CORE LOADING D IAGRAM..........................................................................................................................

8 2.1 1.

FIGURE REFERENCES..................................................................................................................................

8 2.12.

A DDITIONAL SLM CPR LICENSING COND ITIONS...................................................................................

9 2.13.

SUM M ARY..................................................................................................................................................

9 3.0 RE FER EN C ES..............................................................................................................................................

10 List of Figures FIGURE 1. CURRENT CYCLE CORE LOADIN G D IA GRAM.............................................................................................. 11 FIGURE 2. PREVIOUS CYCLE CORE LOADING D IAGRAM.........................................................................................

12 FIGURE 3. FIGURE 4.1 FROM NED C-32601 -P-A......................................................................................................... 13 FIGURE 4. FIGURE 111.5-1 FROM N ED C-32601P-A...................................................................... 13 FIGURE 5. FIGURE 111.5-2 FROM N ED C-32601P-A.................................................................................................

13 List of Tables TABLE 1. D ESCRIPOPTION OF CORE.................................................................................................................................

14 TABLE 2. SLM CPR CALCULATION M ETHODOLOGIES............................................................................................. 15 TABLE 3. MONTE CARLO CALCULATED SLMCPR vs. ESTIMATE..........................................................................

16 TABLE 4. N ON-POWER D ISTR IBUTION U NCERTAINTIES.........................................................................................

17 TABLE 5. POWER D ISTRIB UTION U NCERTAINTIES....................................................................................................... 19 TABLE 6. CRITICAL POW ER U NCERTAINTIES...............................................................................................................

21 Table of Contents Page 3 of 21

GNF NON-PROPRIETARY INFORMATION Class I GNF S-0000-0068-2643 GNF Attachment 1.0 Methodology GNF performed the Hope Creek Cycle 15 Safety Limit Minimum Critical Power Ratio (SLMCPR) calculation in accordance to NEDE-24011-P-A "General Electric Standard Application for Reactor Fuel" (Revision 15) using the following NRC-approved methodologies and uncertainties:

  • NEDC-32601P-A "Methodology and Uncertainties for Safety Limit MCPR Evaluations" (August 1999).
  • NEDC-32694P-A "Power Distribution Uncertainties for Safety Limit MCPR Evaluations" (August 1999).
  • NEDC-32505P-A "R-Factor Calculation Method for GEl 1, GEl2 and GE13 Fuel" (Revision 1, July 1999).

Table 2 identifies the actual methodologies used for the previous and current cycle SLMCPR calculations.

2.0 Discussion In this discussion, the TLO nomenclature is used for two recirculation loops in operation, and the SLO nomenclature is used for one recirculation loop in operation. The "Previous Cycle" is Cycle 14, and the "Current Cycle" is Cycle 15.

2.1.

Major Contributors to SLMCPR Change In general, the calculated safety limit is dominated by two key parameters: (1) flatness of the core bundle-by-bundle MCPR distribution, and (2) flatness of the bundle pin-by-pin power/R-factor distribution. Greater flatness in either parameter yields more rods susceptible to boiling transition and thus a higher calculated SLMCPR. MIP (MCPR Importance Parameter) measures the core bundle-by-bundle MCPR distribution and RIP (R-factor Importance Parameter) measures the bundle pin-by-pin power/R-factor distribution. The impact of the fuel loading pattern on the calculated TLO SLMCPR using rated core power and rated core flow conditions has been correlated to the parameter MIPRIP, which combines the MIP and RIP values.

Table 3 presents the MIP and RIP parameters for the previous cycle and the current cycle along with the TLO SLMCPR estimate using the MIPRIP correlation. If the minimum core flow case is applicable, the TLO SLMCPR estimate is also provided for that case although the MIPRIP correlation is only applicable to the rated core flow case. This is done only to provide some reasonable assessment basis of the minimum core flow case trend. In addition, Table 3 presents Methodology Page 4 of 21

GNF NON-PROPRIETARY INFORMATION Class I GNF S-0000-0068-2643 GNF Attachment estimated impacts on the TLO SLMCPR due to methodology deviations, penalities, and/or uncertainties deviations from approved values.

Based on the MIPRIP correlation and any impacts due to deviations from approved values, a final estimated TLO SLMCPR is determined.

Table 3 also provides the actual calculated Monte Carlo SLMCPRs.

Given the bias and uncertainty in the MIPRIP correlation ((

f31)) and the inherent variation in the Monte Carlo results ((

13W],

the change in the Hope Creek Cycle 15 calculated Monte Carlo TLO SLMCPR using rated core power and rated core flow conditions is consistent with the corresponding estimated TLO SLMCPR value.

2.2. Deviations in NRC-Approved Uncertainties Tables 4 and 5 provide a list of NRC-approved uncertainties along with values actually used. A discussion of deviations from these NRC-approved values follows; all of which are conservative relative to NRC-approved values. Also, estimated impact on the SLMCPR is provided in Table 3 for each deviation.

2.2.1.

R-Factor At this time, GNF has generically increased the GEXL R-Factor uncertainty from ((

(3))) to account for an increase in channel bow due to the emerging unforeseen phenomena called control blade shadow corrosion-induced channel bow, which is not accounted for in the channel bow uncertainty component of the approved R-Factor uncertainty.

The step "aY RPEAK" in Figure 4.1 from NEDC-32601P-A, which has been provided for convenience in Figure 3 of this attachment, is affected by this deviation. Reference 4 technically justifies that a GEXL R-Factor uncertainty of ((

131)) accounts for a channel bow uncertainty of up to (( (3))).

The Hope Creek Cycle 15 analysis has addressed the potential for shadow corrosion-induced channel bow by increasing the NRC-approved R-Factor uncertainty from (( 13))) to (( f3()).

Accounting for control blade shadow corrosion-induced channel bow, the Hope Creek Cycle 15 analysis shows an expected channel bow uncertainty of (( 131)), which is bounded by a GEXL R-Factor uncertainty of (( 131)). Thus the use of a GEXL R-Factor uncertainty of (( 1 3))) adequately accounts for control blade shadow corrosion-induced channel bow for Hope Creek Cycle 15 and subsequent cycles that exhibit channel bow uncertainty of (( I13))).

2.2.2.

Core Flow Rate and Random Effective TIP Reading At this time, GNF has not been able to show that the NRC-approved process to calculate the SLMCPR only at the rated core power and rated core flow condition is adequately bounding relative to the SLMCPR calculated at rated core power and minimum core flow, see Reference 5.

The minimum core flow condition can be more limiting due to the control rod pattern used.

GNF has modified the NRC-approved process for determining the SLMCPR to include analyses at the rated core power and minimum licensed core flow point in addition to analyses at the rated core power and rated core flow point. GNF believes this modification is conservative and may in the future provide justification that the original NRC-approved process is adequately bounding.

Discussion Page 5 of 21

GNF NON-PROPRIETARY INFORMATION Class I GNF S-0000-0068-2643 GNF Attachment For the TLO calculations performed at 94.8% core flow, the approved uncertainty values for the core flow rate (2.5%) and the random effective TIP reading (1.2%) are conservatively adjusted by dividing them by 94.8/100. The steps "a CORE FLOW" and "a TIP (INSTRUMENT)" in Figure 4.1 from NEDC-32601P-A, which has been provided for convenience in Figure 3 of this attachment) are affected by this deviation, respectively.

Historically, these values have been construed to be somewhat dependent on the core flow conditions as demonstrated by the fact that higher values have always been used when performing SLO calculations. It is for this reason that GNF determined that it is appropriate to consider an increase in these two uncertainties when the core flow is reduced. The amount of increase is determined in a conservative way. For both parameters it is assumed that the absolute uncertainty remains the same as the flow is decreased so that the percentage uncertainty increases inversely proportional to the change in core flow. This is conservative relative to the core flow uncertainty since the variability in the absolute flow is expected to decrease somewhat as the flow decreases. For the random effective TIP uncertainty, there is no reason to believe that the percentage uncertainty should increase as the core flow decreases for TLO.

Nevertheless, this uncertainty is also increased as is done in the more extreme case for SLO primarily to preserve the historical precedent established by the SLO evaluation. Note that the TLO condition is different than the SLO condition because for TLO there is no expected tilting of the core radial power shape.

The treatment of the core flow and random effective TIP reading uncertainties is based on the assumption that the signal to noise ratio deteriorates as core flow is reduced. GNF believes this is conservative and may in the future provide justification that the original uncertainties (non-flow dependent) are adequately bounding.

The core flow and random TIP reading uncertainties used in the SLO minimum core flow SLMCPR analysis remain the same as in the rated core flow SLO SLMCPR analysis because these uncertainties (which are substantially larger than used in the TLO analysis) already account for the effects of operating at reduced core flow.

2.2.3.

Reactor Pressure Measurement The input for reactor pressure measurement uncertainty was changed from ((131)) to ((I31))]. Hope Creek supplied this conservative value to be used in the GNF SLMCPR analysis.

2.3. Departure from NRC-Approved Methodology No departures from NRC-approved methodologies were used in the Hope Creek Cycle 15 SLMCPR calculations.

NRC-approved methodologies or methodologies that produce a conservative result (less margin to acceptance limits) were used in the Hope Creek Cycle 15 SLMCPR calculations.

Discussion Page 6 of 21

GNF NON-PROPRIETARY INFORMATION Class I GNF S-0000-0068-2643 GNF Attachment 2.4. Fuel Axial Power Shape Penalty At this time, GNF has determined that higher uncertainties and non-conservative biases in the GEXL correlations for the various types of axial power shapes (i.e., inlet, cosine, outlet and double hump) could potentially exist relative to the NRC-approved methodology values, see References 3, 6, and 7. The following table identifies, by marking with an "X", this potential for each GNF product line currently being offered:

((

I t

I -i ]

Axial bundle power shapes corresponding to the limiting SLMCPR control blade patterns are determined using the PANACEA 3D core simulator. These axial power shapes are classified in accordance to the following table:

((

13111 If the limiting bundles in the SLMCPR calculation exhibit an axial power shape identified by this table, GNF penalizes the GEXL critical power uncertainties to conservatively account for the impact of the axial power shape. Table 6 provides a list of the GEXL critical power uncertainties determined in accordance to the NRC-approved methodology contained in NEDE-240 11-P-A along with values actually used.

For the limiting bundles, the fuel axial power shapes in the SLMCPR analysis were examined to determine the presence of axial power shapes identified in the above table. These power shapes were not found; therefore, no power shape penalties were applied to the calculated Hope Creek Cycle 15 SLMCPR values.

Discussion Page 7 of 21

GNF NON-PROPRIETARY INFORMATION Class I GNF S-0000-0068-2643 GNF Attachment 2.5. Methodology Restrictions The four restrictions identified on Page 3 of NRC's Safety Evaluation relating to the General Electric Licensing Topical Reports NEDC-32601P, NEDC-32694P, and Amendment 25 to NEDE-240 11-P-A (March 11, 1999) are addressed in References 1, 2, and 3.

No new GNF fuel designs are being introduced in Hope Creek Cycle 15; therefore, the NEDC-32505-P-A statement "...if new fuel is introducted, GENE must confirm that the revised R-Factor method is still valid based on new test data" is not applicable.

2.6. Minimum Core Flow Condition For Hope Creek Cycle 15 the minimum core flow SLMCPR calculation performed at 94.8% core flow at rated core power condition was not limiting as compared to the rated core flow at rated core power condition.

.2.7. Limiting Control Rod Patterns The limiting control rod patterns used to calculate the SLMCPR reasonably assures that at least 99.9% of the fuel rods in the core would not be expected to experience boiling transition during normal operation or anticipated operational occurrences during the operation of Hope Creek Cycle 15.

2.8. Core Monitoring System For Hope Creek Cycle 15, the 3DMONICORE system will be used as the core monitoring system.

2.9. Power/Flow Map The utility has provided the current and previous cycle power/flow map in a separate attachment.

2.10. Core Loading Diagram Figures 1 and 2 provide the core loading diagram for the current and previous cycle respectively, which are the Reference Loading Pattern as defined by NEDE-2401 1-P-A. Table I provides a description of the core.

2.11. Figure References Figure 3 is Figure 4.1 from NEDC-32601-P-A. Figure 4 is Figure 111.5-1 from NEDC-32601P-A. Figure 5 is Figure 111.5-2 from NEDC-32601P-A.

Discussion Page 8 of 21

GNF NON-PROPRIETARY INFORMATION Class I GNF S-0000-0068-2643 GNF Attachment 2.12. Additional SLMCPR Licensing Conditions Hope Creek has submitted a licensing amendment to increase rated power from 3339 MWt to 3840 MWt, which is reflected in the attached power/flow map. This uprate licensing amendment is currently being reviewed by the NRC with anticipation of approval before Hope Creek Cycle 15 starts up. Recent NRC communications for such uprates have suggested that an 0.02 adder to the SLMCPR will be a licensing condition. In anticipation that this licensing condition will be imposed on the Hope Creek uprate amendment, the SLMCPR has been established by adding 0.02 to the cycle-specific SLMCPR value calculated using the NRC-approved methodologies documented in NEDE-2401 1-P-A (see Table 3).

2.13. Summary The requested changes to the Technical Specification SLMCPR values are 1.08 for TLO and 1.10 for SLO for Hope Creek Cycle 15.

Discussion Page 9 of 21

GNF NON-PROPRIETARY INFORMATION Class I GNF S-0000-0068-2643 GNF Attachment 3.0 References

1. Letter, Glen A. Watford (GNF-A) to U.S. Nuclear Regulatory Commission Document Control Desk with attention to R. Pulsifer (NRC), "Confirmation of 10xl0 Fuel Design Applicability to Improved SLMCPR, Power Distribution and R-Factor Methodologies",

FLN-2001-016, September 24, 2001.

2. Letter, Glen A. Watford (GNF-A) to U.S. Nuclear Regulatory Commission Document Control Desk with attention to J. Donoghue (NRC), "Confirmation of the Applicability of the GEXL14 Correlation and Associated R-Factor Methodology for Calculating SLMCPR Values in Cores Containing GE14 Fuel", FLN-2001-017, October 1.2001.
3. Letter, Glen A. Watford (GNF-A) to U.S. Nuclear Regulatory Commission Document Control Desk with attention to Joseph E. Donoghue (NRC), "Final Presentation Material for GEXL Presentation - February 11,2002", FLN-2002-004, February 12, 2002.
4. Letter, John F. Schardt (GNF-A) to U.S. Nuclear Regulatory Commission Document Control Desk with attention to Mel B. Fields (NRC), "Shadow Corrosion Effects on SLMCPR Channel Bow Uncertainty". FLN-2004-030, November 10, 2004.
5. Letter, Jason S. Post (GENE) to U.S. Nuclear Regulatory Commission Document Control Desk with attention to Chief, Information Management Branch, et al. (NRC), "Part 21 Final Report: Non-Conservative SLMCPR", MFN 04-108. September 29, 2004.
6. Letter, Glen A. Watford (GNF-A) to U.S. Nuclear Regulatory Commission Document Control Desk with attention to Alan Wang (NRC), "NRC Technology Update -

Proprietary Slides - July 31 - August 1, 2002", FLN-2002-015, October 31, 2002.

7. Letter, Jens G. Munthe Andersen (GNF-A) to U.S. Nuclear Regulatory Commission Document Control Desk with attention to Alan Wang (NRC), "GEXL Correlation for 1OX10 Fuel", FLN-2003-005, May 31, 2003.

References Page 10 of 21

GNF NON-PROPRIETARY INFORMATION Class I GNF S-0000-0068-2643 GNF Attachment Figure 1. Current Cycle Core Loading Diagram 58 EM&0F M

M E

58f]

l [0 [K] Mr~S [E]"tM [0 [fl

  • [

M ]*J[

10*"

ID 10

[]

RM101 54 W. W+.

E+

rg 1 FR+i A RWv+ i 52 C[ [E i] 3 -lI1T flF11 -e

[i-e F2! 10[ I11 [] ff 1E 1 0 I1@ENDMil

-id 11iI*

17'YE U

50-CPI

[]0]t I

]_L][]M rf r[@E-3d r[

E]_ -

[EC 17] r[]_LI [

] [] E7[]

E'_

[E_7 r[-0 [

H]i'r*[-! ]

[]T [] *1 N

]

N j2--- L*

FE]jE I

@E]_I]

gT[-E gjg E7] M]rjlIQ_3S M7[g N] []o EMI MlZ T]E] M] M[] E]

[][],

_p[ Q[E _]

91

]

M ]

HD

[911 91 [E RE] M] El M] ML~S m_g3-

_L

-L 8

1-1 mm1 E-

[))

MR,] NO MR 1%

15 NO1*-Lr M

-'II* ]I**

I M M I

M M I

M M I M M I**1 F nm -1

  • rm[,

SoE1-P[l~g[IV 0CAB402-G6.0/16@G4.-100T~- 15-jT6--275 M=GE14-PI 0CNAB393[-@ 8GZr-100- 150 -T6-2884L 2F=GE 14-PrK l

10NB2-5G6.0 27G4.-100T 15-T6PI

-2758 N=GE[ 14-P legCNAB 39-17 0T-150-T6-3008 G=SVA9-P N1 OF1ELR L

1CAS 36-1G50-68-4R 150-T6265 OGE 14-10CNB40014GZ 1100T-15-630 H=SEA6-POCSB61-4G-56U-WR 150-T6-2658 RI1 16 9i11II 1j0flfl((

EEI[II 0 00009 1II11101J0R]-AN 8i----EUF11T~f 10 EO[I O

T 11 8 -

L 1

1 2

1 3 5 1 0 11If15517 19 21 23 25 27 29 31 333S3755719 1 1315 47 ig51 55 5557595 Fuel Type A=SVEA96-P1OCASB36O-12GZ-568U-4WvR-15O-T6-2656 I= same as D B=SVEA96-PI OCASB36O-12G5.O-568U-4WvR-150-T6-2657 J=GE 14-P IOCNAB396-1I7GZ-lOOT-I 50-T6-3007 C=SVEA96-P IOCASB36 1-14GZ-568U-4WvR-150-T6-2658 K=GE 14-P 1OCNAB393-18G4.O-1OOT-150-T6-2885 D=SVEA96-P IOCASB36O-12G5.5/2G2.5-568U-4WvR-150-T6-2659 L--GEI 4-P1 OCNAB4O5-L5GZ-IOOT-1 50-T6-3009 E--GE 14-PI1OCNAB4O2-4G6.O/1 6G4.O-lOOT-150-T6-2757 M=GE14-P IOCNAB393-18GZ-I1OOT-150-T6-2884 F=GE 14-PI1OCNAB4O2-5G6.O/1 4G4.O-lOOT-150-T6-2758 N=GE1 4-P 1OCNAB398-1I7GZ-I1OOT-150-T6-3008 G--SVEA96-P IOCASB36O-12G5.O-568U-4WR-150-T6-2657 O=GE 14-P 1OCNAB400- l4GZ-I1OOT-150-T6-3006 H=SVEA96-P1 OCASB36I -1 4GZ-568U-4WvR-150-T6-2658 Figure 1. Current Cycle Core Loading Diagram Page I I of 21

GNF NON-PROPRIETARY INFORMATION Class I GNF S-0000-0068-2643 GNF Attachment Figure 2. Previous Cycle Core Loading Diagram 60 E_L[D [D]_EA ]

A] [A] E] []_

[A]_[A

[A] [

58 El FI EIFI [ [

E]l []ED E F-56 E[A] E]

[E]rj_0 E_*W

[EE]

[D [DH[

+

[H]__E] [B] E] [] [D [D [f 54 BF B F C1E El 52 EA~]

[E] [E]F] [E] i-fl_1___ [E] E] [E][] E)) *_ [DE

[E]

L_1] [E] EI]

ED] [E] [Q]

50 W

~

j

- 0IE

-L-E EiE lE El~~~~~~~

~~

-El M E D iWEE mM]I] E 46

[DIE) EW[] JI E)) E]EEEE 44 E]

E]

[]

[E] []

[J] [E] IT]L[][I[E F*iJLc--]

[E] E)) [EJ]

i-1*ii -clE[ ] [E]

[]

0 E

E'c"I__l" E'B-10 E-I 44 3A*ID IB MID BIRIIE]

40

[A]IEE] E__FGJ

[CD EE] F] E[] E] [E] E] [A] [J] [1] [CD EC] ED]_lr- [AZ] Ec]

F[J] [B] C]

E]IF C_2F FIC E

34 A FW

]

M

[D C J_

B COF D

B

[]M C]

A-IE]

I'M NE [

IE)

[DIE]

WE"R0LEI[

I L-El 30

] [E] [E-- [] [] [] [A] E]-I -l J] [C]

C

]

B

]

B JD MD E]

C[

[E]

B] C] C] JE] C-

-A DI-IDW]IE 0E1EDWE))[ R 11E n I]

[E]

l-32 EA

[E]*-

E__]I-] E] E[E] E]

[] _LE]- E]- L[] E] [] ] [E]*I-f E iT_*-

[B]

EC]

E]

[]

[DDEL] E] E]*-

QLrll-30 EDM]8XME

  • I1 9[DI]0 D]ME]

WIMIE D IFEe [Ell- -l

  • 6 [] FIILE] [][]

_]

[

E]_ E] FI__F

[] [D E]IJE] I_[D-

[D_12F-I [D [D J] E Ell [D EIjI]

E 28 E][EEAI[E] [DE EJ]

EC Ii-

]

]L*-

E)) [D[

ElF Ellr-

_L*[D

[]l[

26 r]M W ]E] ED F0MINEJ J--E PI ]

[]

122 5IE 7DE ERI 11 W13 15 E17 19 E%1 23,2 252 2

1 3353 3

1 F2`3 454

`4 1

53 L!575 FuE] MyE ENE-

[1EPEElPIEF]

22 B F

C BF ~

5 I

~

FC HO D

A CF J

B C

18 Bl FE C

E-F I5E]

B CIE ONE]j~

E-TE M70WN E l WEIJ E AA 10DOM A=SVEA96-P 10CASB360- 12GZ-568U-4WR-150-T6-2656 (Cycle 11)

I=SVEA96-P IOCASB360- 12G5.5/2G2.5-568U B=SVEA96-PIOCASB360-12G5.0-568U-4WR-150-T6-2657 (Cycle 11)

-4WR-150-T6-2659 (Cycle 12)

C=SVEA96-PI OCASB36 I

14GZ-568U-4WR-I50-T6-2658 (Cycle 12)

J=GEI4-P1CNAB393-18G4.0-T-150-T6-2885(Cycle 14)

D=SVEA96-P10OCASB360-1I2G5.5/2G2.5-568U-4WR-150-T6-2659 (C 12)

K=GEI14-P IOCNAB393-18GZ-100OT-150-T6-2884 (Cycle 14)

E=GEI 4-P 10OCNAB402-4G6.0/1 6G4.O-100OT-1 50-T6-2757 (Cycle 13 )

F=GEI14-PI1OCNAB402-5G6.0/14G4.0- l00T-150-T6-2758 (Cycle 13)

G=SVEA96-P I 0CASB360- 12G5.0-568U-4WR-150-T6-2657 (Cycle 11 )

H=SVEA96-P10OCASB361 -14GZ-568U-4WR-150-T6-2658 (Cycle 12)

Figure 2. Previous Cycle Core Loading Diagram Pacre 12 of 21 1-1

GNF NON-PROPRIETARY INFORMATION Class I GNF S-0000-0068-2643 GNF Attachment Figure 3. Figure 4.1 from NEDC-32601-P-A

((131))

Figure 4. Figure 111.5-1 from NEDC-32601P-A

((131))

Figure 5. Figure 111.5-2 from NEDC-32601P-A

(( 131))

Figure 3. Figure 4.1 from NEDC-32601-P-A Page 13 of 21

GNF Non-Proprietary Information Class I GNF S-0000-0068-2643 GNF Attachment Table 1. Desclription of Core Previous Cycle Previous Cycle Rated Current Cycle Current Cycle Rated Description Minimum Core Flow Core Flow Limiting Minimum Core Flow Core Flow Limiting Limiting Case Case Limiting Case Case Number of Bundles in the 764 764 764 764 Core Limiting Cycle Exposure Point (i.e.

BOC BOC EOC EOC BOC/MOC/EOC)

Cycle Exposure at Limiting Point 200 200 11000 11000 (MWd/STU)

% Rated Core Flow 76.6*

100 94.8*

100 Reload Fuel Type GE14 GE14 GEl4 GEl4 Latest Reload Batch 20.4 20.4 29.8 29.8 Fraction, %

Latest Reload Average Batch Weight %

3.93 3.93 4.00 4.00 Enrichment Core Fuel Fraction, %:

GE14 41.9 41.9 71.7 71.7 SVEA96 58.1 58.1 28.3 28.3 Core Average Weight %

3.76 3.76 3.88 3.88 Enrichment

  • Refer to the Power/Flow map for lowest flow at rated power.

Table 1. Description of Core Pacye 14 of 21 L_

GNF Non-Proprietary Information Class I GNF S-0000-0068-2643 GNF Attachment Table 2. SLMCPR Calculation Methodologies Previous Cycle Previous Cycle Rated Current Cycle Current Cycle Rated Description Minimum Core Flow Core Flow Limiting Minimum Core Flow Core Flow Limiting Limiting Case Case Limiting Case Case Non-power Distribution NEDC-32601P-A NEDC-32601P-A NEDC-32601P-A NEDC-32601P-A Uncertainty Power Distribution NEDC-32694P-A NEDC-32694P-A NEDC-32694P-A NEDC-32694P-A Methodology Power Distribution NEDC-32694P-A NEDC-32694P-A NEDC-32694P-A NEDC-32694P-A Uncertainty Core Monitoring System 3DMONICORE 3DMONICORE 3DMONICORE 3DMONICORE Table 2. SLMCPR Calculation Methodologies Page 15 of 21

GNF Non-Proprietary Information Class I GNF S-0000-0068-2643 GNF Attachment Table 3. Monte Carlo Calculated SLMCPR vs. Estimate Previous Cycle Previous Cycle Rated Current Cycle Current Cycle Rated Description Minimum Core Flow Core Flow Limiting Minimum Core Flow Core Flow Limiting Limiting Case Case Limiting Case Case

[U 13111 Table 3. Monte Carlo Calculated SLMCPR vs. Estimate Page 16 of 21

GNF Non-Proprietary Information Class i GNF S-0000-0068-2643 GNF Attachment Table 4. Non-Power Distribution Uncertainties Nominal (NRC-Previous Cycle Previous Cycle Current Cycle Current Cycle Approved) Value Minimum Core Rated Core Flow Minimum Core Rated Core Flow a c (%)

Flow Limiting Case Limiting Case Flow Limiting Case Limiting Case GETAB Feedwater Mow 1.76 N/A N/A N/A N/A Measurement Feedwater Temperature 0.76 N/A N/A N/A N/A Measurement Reactor Pressure Mea sure 0.50 N/A N/A N/A N/A Measurement Core Inlet Temperature 0.20 N/A N/A N/A N/A Measurement Total Core Flow 6.0 SLO/2.5 TLO N/A N/A N/A N/A Measurement Channel Flow Area 3.0 N/A N/A N/A N/A Variation Friction Factor 10.0 N/A N/A N/A N/A Multiplier Channel Friction FactorMutipi 5.0 N/A N/A N/A N/A Factor Multiplier Table 4. Non-Power Distribution Uncertainties Page 17 of 21

GNF Non-Proprietary Information Class I GNF S-0000-0068-2643 GNF Attachment Table 4. Non-Power Distribution Uncertainties Nominal (NRC-Previous Cycle Previous Cycle Current Cycle Current Cycle Approved) Value Minimum Core Rated Core Flow Minimum Core Rated Core Flow

+ g (%)

Flow Limiting Case Limiting Case Flow Limiting Case Limiting Case NEDC-32601-P-A I1 I

I I

I I

I Table 4. Non-Power Distribution Uncertainties Page 18 of 21

GNF Non-Proprietary Information Class I GNF S-0000-0068-2643 GNF Attachment Table 5. Power Distribution Uncertainties Nominal (NRC-Previous Cycle Previous Cycle Current Cycle Current Cycle Description Approved) Value Minimum Core Rated Core Flow Minimum Core Rated Core Flow

+/- * (%)

Flow Limiting Case Limiting Case Flow LiMiting Case Limiting Case GETAB/NEDC-32601-P-A GEXL R-Factor

[E {3)]

N/A N/A N/A N/A Random Effective 2.85 SLO/1.2 TLO N/A N/A N/A N/A TIP Reading Systematic Effective 8.6 N/A N/A N/A N/A TIP Reading NEDC-32694-P-A, 3DMONICORE GEXL R-Factor

(( 313))

((

"3)))

E[

[3)))

(((3)))

((

131))

Random Effective 2.85 SLO/1.2 TLO 2.85 SLO/1.2 TLO 2.85 SLO/1.2 TLO 2.85 SLO/1.2 TLO 2.85 SLO/I.2 TLO TIP Reading TIP Integral 1 311]

E[ 131]

(((3)))

E1

]3))]

(( {31))

Four Bundle Power Distribution 131]j Surrounding TIP 3]

(( (3{))

]

[

3}][3))

Location Contribution to B undle Pow er "I))

"I))

131]j "I))

Uncertainty Due to LPRM Update Table 5. Power Distribution Uncertainties Page 19 of 21

GNF Non-Proprietary Information Class I GNF S-0000-0068-2643 GNF Attachment Table 5. Power Distribution Uncertainties Nominal (NRC-Previous Cycle Previous Cycle Current Cycle Current Cycle Description Approved) Value Minimum Core Rated Core Flow Minimum Core Rated Core Flow a

g (%)

Flow Limiting Case Limiting Case Flow Limiting Case Limiting Case Contribution to Bundle Power Due to

(( {3}))

(( {3}))

(({3}))

(({3]3]

Failed TIP Contribution to Bundle Power Due to

(( {3}))

(( (3)))

((13)1]

(({31))

(((3)))

Failed LPRM Total Uncertainty in Calculated Bundle

(( 131))

(((3)))

((3T))

((131))

((]3)]

Power Uncertainty of TIP Signal Nodal E[ 13)))

E[

{31))

E13 3

))]

[iE 3}))

([E 3 )))

Uncertainty Table 5. Power Distribution Uncertainties Page 20 of 21

GNF Non-Proprietary Information Class I GNF S-0000-0068-2643 GNF Attachment Table 6. Critical Power Uncertainties T

Value Previous Cycle Previous Cycle Current Cycle Current Cycle Description Nominal Minimum Core Rated Core Flow Minimum Core Rated Core Flow

+/- o (%)

Flow Limiting Case Limiting Case Flow Limiting Case Limiting Case 131))

Table 6. Critical Power Uncertainties Page 21 of 21