ML082490152: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
(StriderTol Bot change)
 
(One intermediate revision by the same user not shown)
Line 17: Line 17:


=Text=
=Text=
{{#Wiki_filter:"Duke                                                                  DAVE BAXTER Energ* rgy Vice President Oconee Nuclear Station Duke Energy Corporation ON01 VP17800 Rochester Highway Seneca, SC 29672 864-885-4460 864-885-4208 fax dabaxter@dukeenergy.com August 28, 2008 U.S. Nuclear Regulatory Commission Document Control Desk Washington, DC 20555
{{#Wiki_filter:}}
 
==Subject:==
Duke Energy Carolinas, LLC Oconee Nuclear Station, Unit 1 Docket No. 50-269 Unit 1 EOC 24 Refueling Outage Inservice Inspection Report Fourth Ten-Year Inservice Inspection Interval Please find attached a copy of the Inservice Inspection Report for Oconee Unit 1 End of Cycle 24 Refueling Outage. This report is submitted pursuant to Section XI of the ASME Boiler and Pressure Vessel Code, 1998 Edition, with 2000 addenda, Subsubarticles IWA 6230 and IWA-6240.
This report does not include activities specific to the Steam Generator Tube Inservice Inspection. An additional summary report which documents the Steam Generator Tube Inservice Inspection of the Unit 1 EOC-24 Refueling Outage will be transmitted separately.
If there are any questions you may contact Corey Gray at (864) 886-6325.
Very truly yours, Dave Baxter, Site Vice-President Oconee Nuclear Station Attachment www. duke-energy,com
 
U. S. Nuclear Regulatory Commission August 28, 2008 Page 2 xc wo/attachment:  Luis Reyes Region II Administrator U.S. Nuclear Regulatory Commission 61 Forsyth Street, S. W., Suite 23T85 Atlanta, GA 30303 Leonard Olshan, Projects Manager Office of Nuclear Reactor Regulation U. S. Nuclear Regulatory Commission Washington, D. C. 20555 Mr. Andy Hutto NRC Senior Resident Inspector Oconee Nuclear Station
 
INSERVICE INSPECTION REPORT DUKE ENERGY CAROLINAS OCONEE NUCLEAR STATION UNIT 1 TWENTY-FOURTH REFUELING OUTAGE W Duke vEnergy
 
Owner's Report 0                                          For INSERVICE INSPECTIONS OCONEE UNIT 1 2008 REFUELING OUTAGE EOC24 (OUTAGE 3)
Plant Location: 7800 Rochester Highway, Seneca, South Carolina 29672 NRC Docket No. 50-269 Commercial Service Date: July 15, 1973 Document Completion Date____
Owner: Duke Energy Carolinas 526 South Church St.
Charlotte, N. C. 28201-1006 Revision 0 Prepared By:    (QA__  __  Cg_                              Date  7-          o8 Reviewed By:                                                  Date  ?7- 2      '?
                                                                                "'Z-Approved By:                _  _ _ _ _      _  _    _  _    Date  7    3I
 
FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules
: 1. Owner: Duke Energy Carolinas, 526 S. Church St.. Charlotte, NC 28201-1006 (Name and Address of Owner)
: 2. Plant:    Oconee Nuclear Station, 7800 Rochester Highway, Seneca, SC 29672 (Name and Address of Plant)
: 3. Plant Unit:    1    4. Owner Certificate of Authorization (if required)  N/_A
: 5. Commercial Service Date: July 15, 1973            6.National Board Number for Unit N/A
: 7. Components Inspected:
Component or        Manufacturer        Manufacturer            State or          National Appurtenance            Installer        Installer Serial      Province No.        Board No.
No.
See Section 1.1 in the Attached Report Note: Supplemental sheets in the form of lists, sketches, or drawings may be used provided (1) size is 81/2 in. x 11 in., (2) information in items 1 through 6 on this data report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
Total number of pages contained in this report 263
 
4i FORM NIS-1 (Back)
: 8.      Examination Dates          December 15, 2006                        to  June 1,2008
: 9.      Inspection Period Identification:          Second Period
: 10. Inspection Interval Identification:          Fourth Interval
: 11. Applicable Edition of Section XI            1998                      Addenda      2000
: 12. Date/Revision of Inspection Plan:          January 26, 2008/Revision 1
: 13. Abstract of Examinations and Tests. Include a list of examinations and tests and a statement concerning status of work required for the Inspection Plan.          See Sections 2.0, 3.0 and 6.0
: 14. Abstract of Results of Examination and Tests:                          See Sections 4.0 and 6.0
: 15. Abstract of Corrective Measures.                                        See Subsection 4.3 We certify that a) the statements made in this report are correct b) the examinations and tests meet the Inspection Plan as required by the ASME Code,. Section XI,. and c) corrective measures taken conform to the rules of the ASME Code, Section XI.
Certificate of Authorization No. (if applicable)                      NA          Expiration Date          NA Date                                  Signed          Duke Energy              By 7/711                                      Carolinas Owner CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Al.eogrA/          ,.*,W,.          employed by Hartford Steam Boiler of '
Connecticut (HSBCT) have inspected the components described in this Owner's Report during,the period
          .1z -,/s- -o          to    * -/- od                      , and state that to the best of my knowledge and belief, the Owner has performed examinations and tests and taken corrective measures described in the Owner's Report in accordance with the Inspection Plan and as required by the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations, test, and corrective measures described in this Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection Commissions        __________-_____________
    "'-46spector's Signature                                      National Board, State, Province, and Endorsements Date
* 7-08 HSBCT 200 Ashford Center North Suite 205 Atlanta, GA. 30338-4860 (800) 417-3721 www.hsbc.com
 
DISTRIBUTION LIST
: 1. Duke Energy Carolinas Nuclear Technical Services Division Section XI Inspection Program Section
: 2. NRC Document Control Desk
: 3. HSBCT (AIA) c/o ANII at Oconee Note: The following personnel are to be notified via e-mail after the Inservice Inspection Report has been stored in the Nuclear Electronic Document Library:
GO Nuclear Assurance c/o Bruce Nardoci Inspection Services (ISI Coordinator)
 
TABLE OF CONTENTS Section                          Title                  Revision 1.0  General Information                                0 2.0  Fourth Ten Year Interval Inspection Status        0 3.0  Final Inservice Inspection Plan                    0 4.0  Results of Inspections, Performed                  0 5.0  Owners Report for Repair/Replacement Activities    0 6.0  Pressure Testing                                  0
 
1.0    General Information This report describes the Inservice Inspection of Duke's Oconee Nuclear Station, Unit 1 EOC 24 (Outage 3 of the fourth interval). This is the first outage in the second inspection period of the Fourth Ten-Year Interval. ASME Section XI, 1998 Edition with the 2000 Addenda, was the governing Code for selection and performing of the ISI examinations.
Included in this report are: the inspection status for each examination category, the final inservice inspection plan, the inspection results for each item examined, and corrective actions taken when reportable conditions were found. In addition, there is an Owner's Report for Repair/Replacement Section included for completed NIS-2 documentation of repairs and replacements.
1.1    Identification Numbers Manufacturer Item          Manufacturer      or Installer        State or      National or Installer      Serial NO.        Province No. Board No.
Reactor Vessel      Babcock & Wilcox    620-0003-51-52        N/A          N-101 Reactor Vessel      Babcock & Wilcox    068S-01                N/A            202 Head (replaced head)
Steam Generator A Babcock & Wilcox      006K01                N/A            205 Steam Generator B Babcock & Wilcox      006K02                N/A            206 Pressurizer        Babcock & Wilcox    620-0003-59            N/A          N-102 Main Steam          Duke Power                  NA            NA            NA System Auxiliary Steam    Duke Power                  NA            NA            NA System Feedwater System    Duke Power                  NA            NA            NA Emergency          Duke Power                  NA            NA            NA Feedwater System Steam Generator    Duke Power                  NA            NA            NA Flush System Condensate          Duke Power                  NA            NA            NA System Vents and Exhaust  Duke Power                  NA            NA            NA System                                I EOC 24 Refueling Outage Report                                                  Page 1 of 4 Oconee Unit 1                                                                    Revision 0 Section 1                                                                        July 17, 2008
 
Manufacturer Item        Manufacturer or Installer    State or      National or Installer Serial No. Province No. Board No.
Condenser          Duke Power            NA          NA            NA Circulating Water High Pressure      Duke Power            NA          NA            NA Service Water System Low Pressure      Duke Power            NA          NA            NA Service Water System Reactor Coolant    Duke Power            NA          NA            NA System High Pressure      Duke Power            NA          NA            NA Injection System Low Pressure      Duke Power            NA          NA            -NA Injection System Reactor Building  Duke Power            NA          NA            NA Spray System                                                        ..
Component          Duke Power            NA          NA            NA Cooling System Spent Fuel Cooling Duke Power            NA          NA            NA System Vents - Reactor    Duke Power            NA          NA            NA Building Components Drains - Reactor  Duke Power            NA          NA            NA Building Components                                    I EOC 24 Refueling Outage Report                                      Page 2 of 4 Oconee Unit 1                                                        Revision 0 Section 1                                                            July 17, 2008
 
1.2    Personnel,Equipment and MaterialCertifications All personnel who performed or evaluated the results of inservice inspections during the time frame bracketed by the examination dates shown on the NIS-1 Form were certified in accordance with the requirements of the 1998 Edition of ASME Section XI with the 2000 addenda including Appendix VII for ultrasonic inspections. In addition, ultrasonic examiners were qualified in accordance with ASME Section XI, Appendix VIII, and the1998 Edition with the 2000 Addenda through the Performance Demonstration Initiative (PDI) for Supplements 2, 3, 4, 6, 10 and 11. Preservice examinations of weld overlays were conducted in accordance with Code Case N-504-2 including non-mandatory Appendix Q.
The appropriate certification records for each inspector, calibration records for inspection equipment, and records of materials used (i.e., NDE consumables) are on file at Oconee Nuclear Station or copies can be obtained by contacting Duke Energy's Corporate Office in Charlotte, North Carolina.
The copies of the certification records for Washington Group International, Structural Integrity inspectors and Atlantic Group inspectors can be obtained by contacting Duke Energy's Corporate Office in Charlotte, North Carolina.
1.3      Reference Documents The following reference documents apply to the inservice inspections performed during this report period. A copy may be obtained by contacting the ISI Plan Manager at Duke's Corporate Office in Charlotte, North Carolina.
Code Case N-460 (Applicable to items in this report where less than 100%
coverage of the required weld examination volume was achieved.) These items are identified on the Run D that is located in Section 4 of this report.
Code Case N-695 (Qualification Requirements for dissimilar metal piping welds)
Items are identified by the use of UT procedure PDI-UT-10 and are listed in the Plan Report in section 3.0 of this report as dissimilar metal welds.
Code Case N-504-2 (Applicable to items that weld overlay was performed on.)
During 1 EOC-24 outage, there were welds that had weld overlay performed on them and the PSI exams were performed per Code Case N-504-2.
Duke Power Company Problem Investigation Process Report # 0-08-02894.
This PIP was written to track the corrective action for limited coverage on UT examinations of welds that were inspected during EOC-24 for Unit 1.
PIP 0-08-02115 was written to document boron deposits found during a visual examination (VT-1) on flange 1-51A-5-1B1-FLG (summary number #
01 .B7.50.0007).
EOC 24 Refueling Outage Report                                                  Page 3 of 4 Oconee Unit 1                                                                    Revision 0 Section 1                                                                        July 17, 2008
 
Duke Power Company Problem Investigation Process Report # 0-08-02634. This PIP was written to document evidence of leakage found during a VT augmented examination. (Component ID # 1-RPV HEAD PEN, Summary Number 01.G11.1.0002)
Request for Relief 03-006 (Allows Duke and Alternative for the Snubber Examinations required in IWF-5000 for the 4th interval.)
1.4    Augmented and Elective Examinations Augmented and elective examination information found within this Inservice Inspection Report is not required by the ASME Section XI Code; therefore, it is exempt from ANII review, verification, and/or record certification.
1.5    Responsible Inspection Aqencv Hartford Steam Boiler of Connecticut (HSBCT) is responsible for the third party inspections required by ASME Section XI.
Authorized Nuclear Inservice Inspector(s)
Name:                Gary Brouette, Nancy Slaughter Employer:            HSBCT.
Business Address: 200 Ashford Center North Suite 205 Atlanta, GA 30338-4860 (800) 417-3721 www.hsbct.com EOC 24 Refueling Outage Report                                              Page 4 of 4 Oconee Unit 1                                                              Revision 0 Section 1                                                                  July 17, 2008
 
2.0      Fourth Ten Year Interval Inspection Status The completion status of inspections required by the 1998 ASME Code Section Xl, with the 2000 Addenda, is summarized in this section. The requirements are listed by the ASME Section XI Examination Category as defined in Table IWB-2500-1 for Class 1 Inspections, Table IWC-2500-1 for Class 2 Inspections, and IWF-2500-1 for Class 1 and 2 Component Supports. Augmented inspections are also included.
Class 1 Inspections Examination                                  Inspections      Inspections      Percentage      *Deferral Category              Description          Required        Completed        Completed        Allowed B-A            Pressure Retaining Welds        13 Welds        0.5 Weld          4%              Yes in Reactor Vessel B-B            Pressure Retaining Welds        10 Welds        5 Welds          50%              No in Vessels Other than Reactor Vessel B-D            Full Penetration Welds of            54              14          26%            Partial Nozzles in Vessels            Inspections      Inspections Inspection Program B                                      ,,
B-F            Pressure Retaining              2 Welds        0 Welds          0%              Yes Dissimilar Metal Welds              **
B-G-1          Pressure Retaining Bolting      125 Items      82.66 Items        66%              Yes Greater than 2 Inches in Diameter B-G-2          Pressure Retaining Bolting      22 Items        14 Items        64%              No 2 Inches and Less in Diameter B-J            Pressure Retaining Welds        165 Welds        69 Welds        42%              No in Piping                          ....
B-K            Welded Attachments for              10              4            40%              No Vessels, Piping, Pumps and Valves
* Deferral of inspection to the end of the interval as allowed by ASME Section XI Tables IWB and 'IWC 2500-1.
The total of 7 welds for Category B-F that was listed in the EOC-23 Inservice Inspection Report was changed to 2 welds for the EOC-24 report because 5 welds on the Pressurizer had weld overlay performed on them and are no longer in Category B-F. The five welds will be examined per Appendix Q in the future.
***The total of 18 items for Category B-G-2 that was listed in the EOC-23 Inservice Inspection Report was changed to 22 items for the EOC-24 report because 4 B7.50 items were added to the ISI Plan.
**** The total of 168 welds for Category B-J that was listed in the EOC-23 Inservice Inspection Report was changed to 165 welds for the EOC-24 report because 3 B9.11 welds had weld overlay performed on them and are no longer in Category B-J. The 3 overlay welds will be examined per Appendix Q in the future.
***** The total of 17 attachments for category B-K that was listed in the EOC-23 Inservice Inspection Report was changed to 10 attachments for the EOC-24 report because Code Case N-700 was adopted and 7 welded attachments for the pressurizer were removed from the examination schedule.
EOC 24 Refueling Outage Report                                                              Page 1 of 4 Oconee Unit 1                                                                                Revision 0 Section 2                                                                                    July 17, 2008
 
Class 1 Inspections (Continued)
Examination                                      Inspections      Inspections      Percentage    *Deferral Category                    Description          Required        Completed        Completed      Allowed B-Li              Pressure Retaining Welds          1 Weld          1 Weld          100%          Yes in Pump Casings B-L-2              Pump Casings                      1 Casing        0 Casing          0%            Yes B-M-1              ,PressureRetaining            1 Valve Body    1 Valve Body        100%          Yes Welds in Valve Bodies              Weld            Weld B-M-2              Valve Bodies                      3 Valves        1 Valves        33%            Yes B-N-1              Interior.of Reactor Vessel    3 Inspections    1 Inspection      33%            No B-N-2              Welded.Core Support            1 Inspection    0 Inspections        0%            Yes Structures and Interior Attachments to Reactor Vessels B-N-3              Removable Core Support          1 Inspection    0 Inspections        0%            Yes Structures                                                    1 B-0                Pressure Retaining Welds        12 Housing        4 Housing        33%            Yes in Control Rod Housings            Welds            Welds B-P                All Pressure Retaining Components                          REFERENCE SECTION 6.0 OF THIS REPORT B-Q                Steam Generator Tubing              N/A              N/A            N/A            N/A F-A                Class 1 Component              37 Supports      19 Supports        51%            No F1.10 & F1.040    Supports (Except items.            Snubbers)
F-A                Class 1 Component                                                                  **
F1.050 items      Supports, Snubbers
* Deferral of inspection to the end of the interval as allowed by ASME Section Xl Tables IWB and IWC 2500-1.
Inspected under Selected License Commitment 16.9.18 per Relief Request 03-006 EOC 24 Refueling Outage Report                                                                Page 2 of 4 Oconee Unit 1                                                                                Revision 0 Section 2                                                                                    July 17, 2008
 
Class 2 Inspections Examination                                      Inspections      Inspections    Percentage      *Deferral Category                    Description          Required        Completed      Completed      Allowed C-A                Pressure Retaining Welds        11 Welds          8 Welds        73%            No in Pressure Vessels C-B                Pressure Retaining Nozzle        4 Welds          1 Welds        25%            No Welds in Vessels C-C                Integral Attachments for            37              .18        49%            No Vessels, Piping, Pumps        Attachments      Attachments and Valves C-D                Pressure Retaining Bolting        2 Items          1 Items      50%            No Greater Than 2 Inches in Diameter C-F-1              Pressure Retaining Welds        184 Welds        83 Welds        45%            No in Austenitic Stainless Steel or High Alloy Piping C-F-2              Pressure Retaining Welds        74 Welds        30 Welds        41%            No in Carbon or Low Alloy Steel Piping C-G                Pressure Retaining Welds            N/A              N/A          N/A            N/A in Pumps and Valves                          I C-H                All Pressure Retaining Components                          REFERENCE SECTION 6.0 OF THIS REPORT F-A                Class 2 Component              138 Supports      69 Supports      50%            No F1.020 & F1.040    Supports (Except items.              Snubbers)                                      _
F-A                Class 2 Component                                                                **
F1.050 items        Supports, Snubbers Deferral of inspection to the end of the interval as allowed by ASME Section Xl Tables IWB and IWC 2500-1.
**
Inspected under Selected License Commitment 16.9.18 per Relief Request 03-006 The total of 33 attachments for Category CC that was listed in the EOC-23 Inservice Inspection Report was changed to 37 attachments for the EOC-24 report because 4 C3.20 items were added to the ISI Plan.
The total of 131 supports for Category F-A Class 2 that was listed in the EOC-23 Inservice Inspection Report was changed to 138 supports for the EOC-24 report because 6 F1.21 items and 1 F1.40 item was added to the ISI Plan.
EOC 24 Refueling Outage Report                                                              Page 3 of 4 Oconee Unit 1                                                                                Revision 0 Section 2                                                                                    July 17, 2008
 
Augmented/Elective Inspections Augmented and elective examination information found within this Inservice Inspection Report is not required by the ASME Section XI Code; therefore, it is exempt from ANII review, verification, and/or record certification.
Item Number                  Description                        PercentageComplete O1 .G1.1          Reactor Coolant Pump Flywheel        100% of EOC 24 Requirements O1 .G2.1          HPI Nozzle Safe End Examinations    None scheduled for EOC 24 O1 .G3.1          Pressurizer Surge Line Examinations  None scheduled for EOC 24 O1.G4.1          Thermal Stress Piping (NRC Bulletin  100% of EOC 24 Requirements 88-08)
O1 .G11.1.0001    Reactor Pressure Vessel Head        None scheduled for EOC 24 Penetration Nozzle by UT Examination per NRC Order EA                  009.
01 .G11.1.0002    Bare Metal Visual Examination of the 100% of EOC 24 Requirements Reactor Pressure Vessel Head Surface per NRC Order EA-03-009.
O1.G12.1          UT Examination per MRP-139          None scheduled for EOC 24 O1.G12.2          UT Examination per MRP-139          None scheduled for EOC 24 O1.G12.3          UT Examination per MRP-139          None scheduled for EOC 24 O1.G13.1          VT-2 Bare Metal Visual per MRP-139  100% of EOC 24 Requirements O1.G13.2          VT-2 Bare Metal Visual per MRP-139  None scheduled for EOC 24 O1.G13.3          VT-2 Bare Metal Visual per MRP-139  None scheduled for EOC 24 O1.G13.4          VT-2 Bare Metal Visual per MRP-139  None scheduled for EOC 24 O1 .G14.1        VT-2 Bare Metal Visual per Oconee    100% of EOC 24 Requirements Response to BL-2004-01 O1 .H1.1          Pressurizer Sensing/Sampling Nozzle  None scheduled for EOC 24 Safe Ends O1 .H2.1          Class 1 RTE Mounting Bosses          100% of EOC 24 Requirements O1 .H3.1          Main Feedwater Piping in the East    None scheduled for EOC 24 and West Penetration Rooms per QA-513J (ER-ONS-04-03) 01 .H4.1          Main Feedwater and Main Steam        100% of EOC 24 Requirements Piping Supports and Attachment Welds per QA-513J (ER-ONS-04-05)
O1 .H5.1          East Penetration Main Feedwater      None scheduled for EOC 24 Spiping welds and attachments O1 .H6.1          Main Feedwater rupture restraint    None scheduled for EOC 24 Sattachment welds EOC 24 Refueling Outage Report                                                    Page 4 of 4 Oconee Unit 1                                                                    Revision 0 Section 2                                                                        July 17, 2008
 
3.0    Final Inservice Inspection Plan The final Inservice Inspection Plan shown in this section lists all ASME Section XI Class 1, Class 2, Class 3, and Augmented examinations credited for this report period.
The information shown below is a field description for the reporting format included in this section of the report:
Summary Number            =  ASME Section XI Tables IWB-2500-1 (Class 1), IWC-2500-1 (Class 2), IWF-2500-1 (Class 1 and Class 2), Augmented Requirements ID Number                =  Unique Identification Number Sys                      =  Component System Identification Iso / Dwg. Numbers        =  Location and/or Detail Drawings Proc                      =  Examination Procedures Insp Req.                -  Examination Technique - Magnetic Particle, Dye Penetrant, etc.
Mat / Sch.                =  General Description of Material Diam. / Thick            -  Diameter/Thickness Cal Blocks                =  Calibration Block Number Comments                  -  General and/or Detail Description EOC 24 Refueling Outage Report                                                  Page 1 of 1 Oconee Unit 1                                                                  Revision 0 Section 3                                                                      July 17, 2008
 
DUKE EA&GYI' NUCLEAR TECHNICAL SERVICES ScheduleWorks                                      Inservice Inspection DatabaseManagement System Plan Report Oconee 1, 4th Interval, Outage 3 (EOC-24)
This report includes all changes through addendum ONS1-087 Summary Num                                                    Insp Component ID / Type          System  ISOIDWG Numbers    Procedure Req          Mat        Sched ThicWDia      Cal Blocks Comments / HistoricalData Cate-go      AUG O1.G1.1.0001                                                                                                                                                  GO1.001.001, GO1.001..001A 1-RCP-1A1                      50  OM-201D-38          54-ISI-117  UT        CS                9.500 /72.000            Reactor Coolant Pump 1A1 Flywheel. The Circumferential          Class 1                                                                                        complete volume of the flywheel shall be examined by UT at approximately 3 year intervals. Reference Section 7 of the ISI Plan, General Requirements. --(GO1.001.001A)When maintenance or repair activities require removal of the flywheel, a surface examination of exposed surfaces and a complete volumetric examination shall be performed if the interval measured from the previous such inspection is greater than 6 2/3 years. Reference Section 7 of the ISI Plan, General Requirements.
O1 .G1.1.0001                                                                                                                                                GO1.001.001, GO1.001..001A 1-RCP-1A1                      50  OM-201D-38          54-ISI-271  MT        CS                9.500 /72.000            Reactor Coolant Pump WA1    Flywheel. The Circumferential          Class 1                                                                                        complete volume of the flywheel shall be examined by UT at approximately 3 year intervals. Reference Section 7 of the ISI Plan, General Requirements. --(GO1.001.001A)When maintenance or repair activities require removal of the flywheel, a surface examination of exposed surfaces and a complete volumetric examination shall be performed if the interval measured from the previous such inspection is greater than 6 2/3 years. Reference Section 7 of the ISI Plan, General Requirements.
Printed 07/17/08 Ick8302 v. 01/19/08                                                    SDQA Cat "C"                        Oconee 1 7/17/2008 5:22:22 PM        Page 1 of 50
 
This report includes all changes
* gh addendum ONSI-087 Oconee 1, 4th Interval, outage 3 (EOC-24)                                                                0 Summary Num                                                      Insp Component ID / Type          System  ISOIDWG Numbers    Procedure Req          Mat              Sched ThiclWDia      Cal Blocks Comments / HistoricalData Categor      AUG O1.G11.1.0002                                                                                                                                                            G11.001.002 1-RPV-HEAD -PEN                50  O-ISIN4-100A-1.1      NDE-68    VT-2    CS-Inconel                0.000 / 0.000              NRC Order EA-03-009 requires bare metal Class 1 OM-201-2271                                                                                    visual examination of 100% of the reactor pressure vessel head surface (including 360 degree's around each RPV head penetration nozzle). For additional information, contact J.M.
Shuping from the Metallurgy, Lab Services Group.
Procedure MP/0/A/1 150/029-001 Procedure NDE-68 in conjunction with MP/O/A/1 150/029-001 should be used to perform the Bare Metal Visual Inspection.
Dissimilar O1.G13.1.0026                                                                                                                                                            G13.001.026 1RC-269-125V                    50  1RC-269                NDE-68    VT-2    SS-Inconel                0.250 / 1.000              1 inch HL SB- 66 Tap SE to CS Nozzle weld Circumferential            Class 1                                                                                                and SS pipe weld.
(Examine the Nozzle to Safe-End weld and the Safe-End to Pipe weld.)
Augmented Inspection Per MRP-1139. Contact Jody Shuping for additional information on this examination.
Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector. Acceptance criteria is "no evidence of borated water leakage."
Dissimilar Pipe to Safe End O1 .G13.1.0027                                                                                                                                                          G13.001.027 1-50-4-125                      50  1-50-4(3)              NDE-68    VT-2    SS-Inconel                1.187 / 1.000              1 inch HL SB-1 66 Tap SE to CS Nozzle weld Circumferential            Class 1                                                                                                and SS pipe weld.
(Examine the Nozzle to Safe-End weld and the Safe-End to Pipe weld.)
Augmented Inspection Per MRP-139. Contact Jody Shuping for additional information on this examination.
Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector. Acceptance criteria is "no evidence of borated water leakage."
Dissimilar Pipe to Safe End SDQA  Cat 'C"                          Oconee 1 7/17/2008 5:22:22 PM        Page 2 of 50 Printed  07/17/08 Ick8302 Printed 07/17/08          v. 01/19/08 1ck8302 v. 01/19/08                                                        SDQA Cat "C"                            Oconee 1 7/17/2008 5:22:22 PM        Page 2 of 50
 
0                                        This report includes all change        ugh addendum ONS1-087 Oconee 1, 4th Interval, outage 3 (EOC-24)
Summary Num                                                      Insp Component ID / Type          System  ISO/DWG Numbe rs    Procedure Req          Mat              Sched ThicklDia      Cal Blocks Comments / HistoricalData Cate-gor    AUG O1.G13.1.0028                                                                                                                                                            G13.001.028 1-50-4-143                      50  1-50-4(1)              NDE-68    VT-2    SS-Inconel                0.250 / 1.000              1 inch HL SB-166 Tap SE to CS Nozzle weld Circumferential            Class 1                                                                                                and SS pipe weld.
(Examine the Nozzle to Safe-End weld and the Safe-End to Pipe weld.)
Augmented Inspection Per MRP-139. Contact Jody Shuping for additional information on this examination.
Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector. Acceptance criteria is "no evidence of borated water leakage."
Dissimilar Pipe to Safe End O1.G13.1.0029                                                                                                                                                            G13.001.029 1-50-4-131                      50  1-50-4(3)              NDE-68    VT-2    SS-Inconel                0.250/1.000              3/4 inch ID HL SB-166 Flowmeter Noz SE to CS Circumferential            Class 1                                                                                                Nozzle weld ahd SS pipe weld.
(Examine the Nozzle to Safe-End weld and the Safe-End to Pipe weld.)
Augmented Inspection Per MRP-1139. Contact Jody Shuping for additional information on this examination.
Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector. Acceptance criteria is "no evidence of borated water leakage."
Dissimilar Pipe to Safe End SDQA  Cat "C'                          Oconee 1 7/17/2008 5:22:22 PM      Page 3 of 50 Printed 07/17/08 Ick8302 Printed 07/17/08          v. 01/19/08 1ck8302 v. 01/19/08                                                        SDQA Cat "C"                            Oconee 1 7/17/2008 5:22:22 PM      Page 3 of 50
 
This report includes all changes*ugh addendum ONSI-087 Oconee 1, 4th Interval,outage 3 (EOC-24)                                                              s Summary Num                                                    Insp Component ID / Type          System  ISOIDWG Numbers    Procedure Req          Mat              Sched Thick/Dia    Cal Blocks Comments / HistoricalData Categor      AUG O1.G13.1.0030                                                                                                                                                          G13.001.030 1-50-4-135                      50  1-50-4(3)            NDE-68    VT-2      SS-Inconel                0.250 / 1.000            3/4 inch ID HL SB-166 Flowmeter Noz SE to CS Circumferential            Class 1                                                                                                Nozzle weld and SS pipe weld.
(Examine the Nozzle to Safe-End weld and the Safe-End to Pipe weld.)
Augmented Inspection Per MRP-139. Contact Jody Shuping for additional information on this examination.
Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector. Acceptance criteria is "no evidence of borated water leakage."
Dissimilar Pipe to Safe End O1.G13.1.0031                                                                                                                                                          G13.001.031 1-50-4-150                      50  1-50-4(1)            NDE-68    VT-2      SS-Inconel                0.250 / 1.000            3/4 inch ID HL SB-166 Flowmeter Noz SE to CS Circumferential            Class 1                                                                                              Nozzle weld and SS pipe weld.
(Examine the Nozzle to Safe-End weld and the Safe-End to Pipe weld.)
Augmented Inspection Per MRP-1139. Contact Jody Shuping for additional information on this examination.
Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector. Acceptance criteria is "no evidence of borated water leakage."
Dissimilar Pipe to Safe End 01/19/08
: v. 01/19/08 1ck8302 v.                                                                SDQA  Cat "C'                          Oconee 17/17/20085:22:22 PM        Page4ofso Printed 07/17/08 lck8302 Printed 07/17/08                                                                            SDQA Cat "C"                            Oconee 1 7/17/2008 5:22:22 PM      Page 4 of 50
 
This report includes all changes t1gh        addendum ONS1-087 10                                                  Oconee 1, 4th Intervaloutage 3 (EOC-24)
Summary Num                                                      Insp Component ID / Type          System  ISO/DWG Numberrs  Procedure Req            Mat            Sched Thick/Dia      C3al Blocks Comments/ HistoricalData Cate-gory    AUG O.1 .G13.1.0032                                                                                                                                                        G13.001.032 1RC-273-143V                  50  1RC-273                NDE-68    VT-2    SS-Inconel                1.187/ 1.000              1 inch HL SB-166 Tap SE to CS Nozzle weld Circumferential          Class 1                                                                                                and SS pipe weld.
(Examine the Nozzle to Safe-End weld and the Safe-End to Pipe weld.)
Augmented Inspection Per MRP-139. Contact Jody Shuping for additional information on this examination.
Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector. Acceptance criteria is "no evidence of borated water leakage."
Dissimilar Pipe to Safe End O1.G13.1.0033                                                                                                                                                          G13.001.033 1-50-4-44A                    50  1-50-4(1)              NDE-68    VT-2    SS-Inconel                0.250 / 1.000              3/4 inch ID HL SB-166 Flowmeter Noz SE to CS Circumferential          Class 1                                                                                                Nozzle weld and SS pipe weld.
(Examine the Nozzle to Safe-End weld and the Safe-End to Pipe weld.)
Augmented Inspection Per MRP-139. Contact Jody Shuping for additional information on this examination.
Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector. Acceptance criteria is "no evidence of borated water leakage."
Dissimilar Pipe to Safe End O1.G14.1.0002                                                                                                                                                          G14.001.002 1-PZR-HTR PLATES              50                        NDE-68    VT-2    CS-Inconel                0.000 / 0.000              Heater Diaphragm Plates located on the Circumferential          Class 1  OM 201-288                                                                                    Pressurizer.
Augmented Inspection Per Oconee Response to BL-2004-01. Contact Jody Shuping and Dave Peltola for additional information on this examination.
Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector. Acceptance criteria is "no evidence of borated water leakage."
Dissimilar Nozzle to Safe End Printed 07/17/08 Ick8302 v. 01/19/08                                                        SDQA Cat "C"                            Oconee 1 7/17/2008 5:22:22 PM        Page 5 of 50
 
This report includes all changes*        ugh addendum ONSl1-087 Oconee 1, 4th Interval, outage 3 (EOC-24)                                                              0 Summary Num Insp Component ID / Type          System  ISO/DWG Numbers    Procedure Req          Mat              Sched Thick/Dia      Cal Blocks Comments / HistoricalData Cate-ory    AUG O1 .G14.1.0003                                                                                                                                                          G14.001.003 1-PZR-HTR SLEEVES              50                        NDE-68    VT-2    CS-Inconel                  0.000 / 0.000            Heater sleeves to diaphragm weld and heater Circumferential          Class 1  OM 201-288                                                                                      sleeves to sheath weld located on the OM 201-152                                                                                      Pressurizer.
Augmented Inspection Per Oconee Response to BL-2004-01. Contact Jody Shuping and Dave Peltola for additional information on this examination.
Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector. Acceptance criteria is "no evidence of borated water leakage."
Dissimilar Nozzle to Safe End O1.G4.1.0005                                                                                                                                                            G04.001.007 1HP-255-6                    51A  1HP-255              NDE-995      UT          SS                    0.375 / 2.500 Component  Inspect 100% of weld & 1" of base material O-ISIN4-101A-1.4                                                                      40378    (axial & circumferential). This weld was 1-51A-Circumferential          Class 1                                                                                                  10-6 until iso 1-51A-10 was deleted and welds were transferred to iso 1HP-255. Reference Section 7 of the ISI Plan, General Requirements.
Elbow to Pipe O1 .G4.1.0006                                                                                                                                                            G04.001.012 1HP-190-12                    51A  1HP-190              NDE-995      UT          SS                    0.375 /2.500  Component  Inspect 100% of weld & 1" of base material 40378    (axial & circumferential). This weld was 1-51A    Circumferential          Class 1                                                                                                  77C until iso 1-51A-5 was deleted and welds transferred to iso 1HP-190. Reference Section 7 of the ISI Plan, General Requirements.
Pipe to Elbow O1.G4.1.0009                                                                                                                                                            G04.001.015 1HP-190-16                    51A  1HP-190              NDE-995      UT          SS                    0.375 /2.500  Component  Inspect 100% of weld & 1" of base material 0-ISIN4-101A-1.4                                                                      40378    (axial & circumferential). Reference Section 7 Circumferential          Class 1                                                                                                  of the ISI Plan, Volume 1.
Pipe to Valve 1HP-488 O1 .G4.1.0010                                                                                                                                                            G04.001.016 1HP-190.13                    51A  1HP-190              NDE-995      UT          SS                    0.375 /2.500  Component  Inspect 100% of weld & 1" of base material 0-ISIN4-101A-1.4                                                                      40378    (axial & circumferential). Reference Section 7 Circumferential          Class 1                                                                                                  of the ISI Plan, General Requirements.
Elbow to Pipe Printed 07/17/08 Ick8302 v. 01/19/08                                                        SDQA Cat "C"                            Oconee 1 7/17/2008 5:22:22 PM        Page 6 of 50
 
This report includes all changes*ugh addendum ONS1-087 Oconee 1, 4th Interval,outage 3 (EOC-24)                                                              0 Summary Num                                                    Insp Component ID / Type          System  ISO/DWG Numbers    Procedure Req          Mat              Sched Thick/Dia    Cal Blocks Comments / HistoricalData Category    AUG O1.G4.1.0011                                                                                                                                                          G04.001.017 1HP-279-4                    51A  1HP-279              NDE-995    UT          SS                    0.375 /2.500  Component  Inspect 100% of weld & 1" of base material 0-ISIN4-101A-1.4                                                                    40378    (axial & circumferential). This weld was 1-51A-Circumferential            Class 1                                                                                              10-4 until iso 1-51A-10 was deleted and welds tranferred to iso 1HP-279. Reference Section 7 of the ISI Plan, General Requirements.
Elbow to Pipe O1.G4.1.0012                                                                                                                                                          G04.001.018 1HP-279-3                    51A  1HP-279              NDE-995    UT          SS                    0.375 /2.500  Component  Inspect 100% of weld & 1" of base material 0-ISIN4-101A-1.4                                                                    40378    (axial & circumferential). This weld was 1-51A-Circumferential            Class 1                                                                                              10-3 until iso 1-51A-10 was deleted and welds tranferred to iso 1HP-279. Reference Section 7 of the ISI Plan, General Requirements.
Elbow to Pipe O1.G4.1.0013                                                                                                                                                          G04.001.019 1HP-279-24                    51A  1HP-279              NDE-995    UT          SS                    0.375 / 2.500 Component  Inspect 100% of weld & 1" of base material 0-ISIN4-101A-1.4                                                                    40378    (axial & circumferential). Reference Section 7 Circumferential          Class 1                                                                                                of the IS] Plan, General Requirements.
Pipe to Valve 1HP-489 O1 .G4.1.0015                                                                                                                                                        G04.001.021 1HP-277-42C                  51A  1HP-277              NDE-995    UT          SS                    0.375 / 2.500 Component  Inspect 100% of weld & 1" of base material 0-ISIN4-101A-1.4                                                                    40378    (axial & circumferential). This weld was 1-51A-Circumferential          Class 1                                                                                                04-42C until iso 1-51A-04 was deleted and welds transferred to iso 1HP-277. Reference Section 7 of the ISI Plan, General Requirements.
Pipe to Elbow O1.G4.1.0016                                                                                                                                                          G04.001.022 1HP-277-43C                  51A  1HP-277              NDE-995    UT          SS                    0.375 /2.500  Component  Inspect 100% of weld & 1" of base material 0-ISIN4-101A-1.4                                                            -      40378    (axial & circumferential). This weld was 1-51A-Circumferential          Class 1                                                                                                04-43C until iso 1-51A-04 was deleted and welds tranferred to iso 1-HP-277. Reference Section 7 of the ISI Plan, General Requirements.
Elbow to Pipe O1.G4.1.0017                                                                                                                                                          G04.001.023 1HP-277-52                    51A  1HP-277              NDE-995    UT          SS                    0.375/2.500  Component  Inspect 100% of weld & 1" of base material 0-ISIN4-101A-1.4                                                                    40378    (axial & circumferential). Reference Section 7 Circumferential          Class 1                                                                                                of the ISI Plan, General Requirements.
Pipe to Valve 1HP-486 Printed 07/17/08 Ick8302 v. 01/19/08                                                        SDQA Cat "C"                            Oconee 1 7/17/2008 5:22:22 PM        Page 7 of 50
 
S                                      This report includes all change          ugh addendum ONSI-087 Oconee 1, 4th Interval, outage 3 (EOC-24)
Summary Num                                                      Insp Component ID / Type          System  ISOIDWG Numbers    Procedure Req            Mat              Sched Thick/Dia      Cal Blocks Comments / HistoricalData Category      AUG O1.G4.1.0019                                                                                                                                                            G04.001.025 1HP-278-22C                  51A  1HP-278              NDE-995      UT          SS                    0.375/ 2.500  Component  Inspect 100% of weld & 1" of base material 0-ISIN4-101A-1.4                                                                      40378    (axial & circumferential). This weld was 1-51A-Circumferential          Class 1                                                                                                  04-22C until iso 1-51A-04 was deleted welds tranferred to 1-HP-278. Reference Section 7 of the ISI Plan, General Requirements.
Pipe to Elbow O1 .G4.1.0020                                                                                                                                                          G04.001.026 1HP-278-23C                  51A  1HP-278              NDE-995    UT          SS                    0.375 /2.500  Component  Inspect 100% of weld & 1" of base material 0-ISIN4-101A-1.4                                                                      40378    (axial & circumferential). This weld was 1-51A-Circumferential          Class 1                                                                                                  04-23C until iso 1-51A-04 was deleted and welds transferred to iso 1-HP-278. Reference Section 7 of the ISI Plan, General Requirements.
Elbow to Pipe O1.G4.1.0021                                                                                                                                                            G04.001.027 1HP-278-24                    51A  1HP-278              NDE-995    UT          SS                    0.375 /2.500  Component  Inspect 100% of weld & 1" of base material 0-ISIN4-101A-1.4                                                                      40378    (axial & circumferential). Reference Section 7 Circumferential          Class 1                                                                                                  of the ISI Plan, General Requirements.
Pipe to Valve 1HP-487 Catego        B-B 01.B2.60.0001                                                                                                                                                          B02.060.001 1-51A-18792-1-V-3            51A  18792-1              NDE-3630      UT          SS                    0.875 / 8.620  40411    Letdown Cooler 1A Inlet Tubesheet Pc. 2 to Circumferential          Class 1  OM-201-3107                                                                                    Channel Body Pc. 3.
Tubesheet to Head 01.12.60.0002                                                                                                                                                          B02.060.002 1-51A-18792-1-V-5            51A  18792-1              NDE-3630      UT          SS                    0.875 / 8.620  40411    Letdown Cooler 1A Outlet Tubesheet Pc. 2 to Circumferential          Class 1  OM-201-3107                                                                                    Channel Body Pc. 3.
Tubesheet to Head Catego        B-G-1 01 .B6.10.0021                                                                                                                                                          B06.010.021 1-RPV-26-203-21                    OM-201-2271            NDE-62    VT-1        CS                      1.300 / 9.250            Reactor Vessel Closure Nut. Reference OM-201-Class 1  B&W128723E                                                                                      2271 RPV Instruction Manual.
Printed 07/17/08 Ick8302 v. 01/19/08                                                        SDQA Cat "C"                            Oconee 1 7/17/2008 5:22:22 PM        Page 8 of 50
 
This report includes all changes
* lh addendum ONSI-087 a
Oconee 1, 4th Interval, ourage 3 (EOC-24)
Summary Num                                                    Insp Component ID / Type          System  ISO/DWG Numbers  Procedure Req            Mat              Sched Thick/Dia    Cal Blocks Comments / HistoricalData Catego        B-G-1 01.16.10.0022                                                                                                                                                    B06.010.022 1-RPV-26-203-22                    OM-201-2271          NDE-62    VT-I-        CS                  1.300 / 9.250            Reactor Vessel Closure Nut. Reference OM-201-Class 1 B&W128723E                                                                                  2271 RPV Instruction Manual.
01.16.10.0023                                                                                                                                                    B06.010.023 1-RPV-26-203-23                    OM-201-2271          NDE-62    VT-1        CS                  1.300 / 9.250            Reactor Vessel Closure Nut. Reference OM-201-Class 1 B&W128723E                                                                                  2271 RPV Instruction Manual.
01.B6.10.0024                                                                                                                                                    B06.010.024 1-RPV-26-203-24                    OM-201-2271          NDE-62    VT-i1        CS                  1.300 / 9.250            Reactor Vessel Closure Nut. Reference OM-201-Class 1 B&W128723E                                                                                  2271 RPV Instruction Manual.
01.B6.10.0025                                                                                                                                                    B06.010.025 1-RPV-26-203-25                    OM-201-2271          NDE-62    VT-1        CS                  1.300 / 9.250            Reactor Vessel Closure Nut. Reference OM-201-Class 1 B&W128723E                                                                                  2271 RPV Instruction Manual.
01.86.10.0026                                                                                                                                                    B06.010.026 1-RPV-26-203-26                    OM-201-2271          NDE-62    VT-I          CS                  1.300 /9.250              Reactor Vessel Closure Nut. Reference OM-201-Class 1 B&W128723E                                                                                  2271 RPV Instruction Manual.
01.86.10.0027                                                                                                                                                    1306.010.027 1-RPV-26-203-62                    OM-201-2271          NDE-62    VT-1          CS                  1.300 / 9.250            Reactor Vessel Closure Nut. Reference OM-201-Class 1 B&W128723E                                                                                  2271 RPV Instruction Manual.
O1.136.10.0028                                                                                                                                                    806.010.028 1-RPV-26-203-28                    OM-201-2271          NDE-62    VT-1          CS                  1.300 / 9.250            Reactor Vessel Closure Nut. Reference OM-201-Class 1 B&W128723E                                                                                  2271 RPV Instruction Manual.
01.86.10.0029                                                                                                                                                    806.010.029 1-RPV-26-203-29                    OM-201-2271          NDE-62    VT-1          CS                  1.300 /9.250              Reactor Vessel Closure Nut. Reference OM-201-Class 1 B&W128723E                                                                                  2271 RPV Instruction Manual.
01.86.10.0030                                                                                                                                                    B06.010.030 1-RPV-26-203-30                    OM-201-2271        NDE-62    VT-1          CS                  1.300 /9.250              Reactor Vessel Closure Nut. Reference OM-201 -
Class 1 B&W128723E                                                                                  2271 RPV Instruction Manual.
Printed 07/17/08 Ick8302 v. 01/19/08                                                      SDQA Cat "C"                          Oconee 1 7/17/2008 5:22:22 PM    Page 9 of 50
 
This report includes all change',        ugh addendum ONSI-087 Oconee 1, 4th Interval, outage 3 (EOC-24)
Summary Num                                                    Insp Component ID / Type          System  ISOIDWG Numbe,rs  Procedure Req          Mat              Sched ThickWDia    Cal Blocks Comments / HistoricalData Categorv      B-G-1 01.B6.10.0031                                                                                                                                                    B06.010.031 1-RPV-26-203-61                    OM-201-2271          NDE-62    VT-1        CS                  1.300 / 9.250            Reactor Vessel Closure Nut. Reference OM-201  -
Class 1 B&W128723E                                                                                  2271 RPV Instruction Manual.
01.66.10.0032                                                                                                                                                    606.010.032 1-RPV-26-203-32                    OM-201-2271          NDE-62    VT-I        CS                  1.300 / 9.250            Reactor Vessel Closure Nut. Reference OM-201-Class 1 B&W128723E                                                                                  2271 RPV Instruction Manual.
01 .B6.10.0033                                                                                                                                                    B06.010.033 1-RPV-26-203-33                    OM-201-2271          NDE-62    V-i-I        CS                  1.300 / 9.250            Reactor Vessel Closure Nut. Reference OM-201-Class 1 B&W128723E                                                                                  2271 RPV Instruction Manual.
01.B6.10.0034                                                                                                                                                    806.010.034 1-RPV-26-203-65                    OM-201-2271          NDE-62    VT-1        CS                  1.300 / 9.250            Reactor Vessel Closure Nut. Reference OM-201-Class 1 B&W128723E                                                                                  2271 RPV Instruction Manual.
01 .B6.10.0035                                                                                                                                                    B06.010.035 1-RPV-26-203-35                    OM-201-2271          NDE-62    VT-1        CS                  1.300 / 9.250            Reactor Vessel Closure Nut. Reference OM-201-Class 1 B&W128723E                                                                                  2271 RPV Instruction Manual.
01.B6.10.0036                                                                                                                                                    B06.010.036 1-RPV-26-203-36                    OM-201-2271          NDE-62    VT-1        CS                  1.300 / 9.250            Reactor Vessel Closure Nut. Reference OM-201-Class 1 B&W128723E                                                                                  2271 RPV Instruction Manual.
01.16.10.0037                                                                                                                                                    B06.010.037 1-RPV-26-203-37                    OM-201-2271          NDE-62    VT-1        CS                  1.300/ 9.250              Reactor Vessel Closure Nut. Reference OM-201-Class 1 B&W128723E                                                                                  2271 RPV Instruction Manual.
01.16.10.0038                                                                                                                                                    B06.010.038 1-RPV-26-203-38                    OM-201-2271          NDE-62    VT-1        CS                    1.300 / 9.250            Reactor Vessel Closure Nut. Reference OM-201 -
Class 1 B&W128723E                                                                                  2271 RPV Instruction Manual.
01.66.10.0039                                                                                                                                                    B06.010.039 1-RPV-26-203-39                    OM-201-2271          NDE-62    VT-1        CS                    1.300 /9.250              Reactor Vessel Closure Nut. Reference OM-201-Class 1 B&W128723E                                                                                  2271 RPV Instruction Manual.
Printed 07/17/08 Ick8302 v. 01/19/08                                                      SDQA Cat "C"                        Oconee 1 7/17/2008 5:22:22 PM      Page 10 of 50
 
This report includes all change*pugh addendum ONS1-087 Oconee 1, 4th Interval, outage 3 (EOC-24) -
Summary Num                                                    Insp Component ID / Type          System  ISO/DWG Numbers      Procedure Req          Mat              Sched Thick/Dia    Cal Blocks Comments / HistoricalData Catego        B-G-1 01.B6.10.0040                                                                                                                                                      806.010.040 1-RP.V-26-203-40                  OM-201-2271            NDE-62    VT-I          CS                  1.300 / 9.250            Reactor Vessel Closure Nut. Reference OM-201-Class 1 B&W128723E                                                                                    2271 RPV Instruction Manual.
01.B6.30.0021                                                                                                                                                      106.030.021 1-RPV-25-203-21                          I-RPV25-20-21 OM-201-2271          PDI-UT-5    UT          CS                    0.000 / 6.500  40420    Reactor Vessel Closure Stud - Removed. Stud Class 1 B&W128723E                                                                                    Length = 63.250. Reference OM-201-2271 RPV Instruction Manual.
01.86.30.0022                                                                                                                                                      806.030.022 1-RPV-25-203-22                    OM-201-2271          PDI-UT-5    UT          CS                    0.000 / 6.500  40420    Reactor Vessel Closure Stud - Removed. Stud ClassY1 B&W128723E                                                                                    Length = 63.250. Reference OM-201-2271 RPV Instruction Manual.
01.86.30.0023                                                                                                                                                      806.030.023 1-RPV-25-203-23                    OM-201-2271          PDI-UT-5    UT          CS                    0.000 / 6.500  40420    Reactor Vessel Closure Stud - Removed. Stud Class 1 B&W128723E                                                                                    Length = 63.250. Reference OM-201-2271 RPV Instruction Manual.
01.86.30.0024                                                                                                                                                      806.030.024 1-RPV-25-203-24                    OM-201-2271          PDI-UT-5    UT          CS                    0.000 / 6.500  40420    Reactor Vessel Closure Stud - Removed. Stud Class 1  B&W128723E                                                                                    Length = 63.250. Reference OM-201-2271 RPV Instruction Manual.
01 .86.30.0025                                                                                                                                                    B06.030.025 1-RPV-25-203-25                    OM-201-2271          PDI-UT-5    UT          CS                    0.000 / 6.500  40420    Reactor Vessel Closure Stud - Removed. Stud Class 1  B&W128723E                                                                                    Length = 63.250. Reference OM-201-2271 RPV Instruction Manual.
01.86.30.0026                                                                                                                                                      B06.030.026 1-RPV-25-203-26                    OM-201-2271          PDI-UT-5    UT          CS-                  0,000 /6.500    40420    Reactor Vessel Closure Stud - Removed. Stud Class 1  B&W128723E                                                                                    Length = 63.250. Reference OM-201-2271 RPV Instruction Manual.
01.86.30.0027                                                                                                                                                      806.030.027 1-RPV-25-203-27                    OM-201-2271          PDI-UT-5    UT          CS                    0.000 / 6.500  40420      Reactor Vessel Closure Stud - Removed. Stud Class 1  B&W128723E                                                                                    Length = 63.250. Reference OM-201-2271 RPV
                                                                                                                              -    Instruction Manual.
Printed 07/17/08 Ick6302 v. 01/19/08                                                        SDQA Cat "C"                          Oconee 1 7/17/2008 5:22:22 PM    Page 11 of 50
 
This report includes all changes*        ugh addendum ONSI-087 Oconee 1, 4th Interval, outage 3 (EOC-24)
Summary Num                                                    Insp Component ID / Type          System  ISOlDIWG Numbers    Procedure Req          Mat              Sched Thick/Dia    Cal Blocks Comments / HistoricalData Cate-go      B-G-1 O1..B6.30.0028                                                                                                                                                    1B06.030.028 1-RPV-25-203-63                    OM-201-2271          PDI-UT-5    UT          CS                  0.000 / 6.500  40420    Reactor Vessel Closure Stud - Removed. Stud Class 1 B&W128723E                                                                                    Length = 63.250. Reference OM-201-2271 RPV Instruction Manual.
01.86.30.0029                                                                                                                                                      B06.030.029 1-RPV-25-203-29                    OM-201-2271          PDI-UT-5    UT          CS                  0.000 / 6.500  40420    Reactor Vessel Closure Stud - Removed. Stud Class 1 B&W128723E                                                                                    Length = 63.250. Reference OM-201-2271 RPV Instruction Manual.
01.B6.30.0030                                                                                                                                                      3B06.030.030 1-RPV-25-203-30                    OM-201-2271          PDI-UT-5    UT          CS                  0.000/ 6.500    40420    Reactor Vessel Closure Stud - Removed. Stud Class 1 B&W128723E                                                                                    Length = 63.250. Reference OM-201-2271 RPV Instruction Manual.
01.B6.30.0031                                                                                                                                                      B06.030.031 1-RPV-25-203-61                    OM-201-2271          PDI-UT-5    UT          CS                  0.000 / 6.500  40420    Reactor Vessel Closure Stud - Removed. Stud Class 1  B&W128723E                                                                                    Length = 63.250. Reference OM-201-2271 RPV Instruction Manual.
01.B6.30.0032                                                                                                                                                      B06.030.032 1-RPV-25-203-32                    OM-201-2271          PDI-UT-5    UT          CS                  0.000 /6.500    40420    Reactor Vessel Closure Stud - Removed. Stud Class 1  B&W128723E                                                                                    Length = 63.250. Reference OM-201-2271 RPV Instruction Manual.
01.86.30.0033                                                                                                                                                      806.030.033 1-RPV-25-203-33                    OM-201-2271          PDI-UT-5    UT          CS                  0.000 / 6.500  40420    Reactor Vessel Closure Stud - Removed. Stud Class 1  B&W128723E                                                                                    Length = 63.250. Reference OM-201-2271 RPV Instruction Manual.
01.86.30.0034                                                                                                                                                      B06.030.034 1-RPV-25-203-34                    OM-201-2271          PDI-UT-5    UT          CS                  -0.000 /6.500    40420    Reactor Vessel Closure Stud - Removed. Stud Class 1  B&W128723E                                                                                    Length = 63.250. Reference OM-201-2271 RPV Instruction Manual.
01.86.30.0035                                                                                                                                                      B06.030.035 1-RPV-25-203-35                    OM-201-2271          PDI-UT-5    UT          CS                  0.000 / 6.500  40420    Reactor Vessel Closure Stud - Removed. Stud Class 1  1B&W128723E                                                                                  Length = 63.250. Reference OM-201-2271 RPV Instruction Manual.
Printed 07/17/08 Ick8302 v. 01/19/08                                                        SDQA Cat "C"                          Oconee 1 7/17/2008 5:22:22 PM    Page 12 of 50
 
This report includes all changes t        gh addendum ONS1-087 Oconee 1, 4th Interval, ouage 3 (EOC-24)
Summary Num                                                    Insp Component ID / Type          System  ISOIDWG Numbers    Procedure Req            Mat            Sched Thick/Dia    Cal Blocks Comments / HistoricalData Catego C            B-G-1 01 .B6.30.0036                                                                                                                                                  B06.030.036 1-RPV-25-203-36                    OM-201-2271        PDI-UT-5    UT          CS                  0.000 / 6.500  40420    Reactor Vessel Closure Stud - Removed. Stud Class 1  B&W128723E                                                                                Length = 63.250. Reference OM-201-2271 RPV Instruction Manual.
01 .B6.30.0037                                                                                                                                                  B06.030.037 1-RPV-25-203-37                    OM-201-2271        PDI-UT-5    UT          CS                  0.000 /6.500    40420    Reactor Vessel Closure Stud - Removed. Stud Class 1  B&W128723E                                                                                Length = 63.250. Reference OM-201-2271 RPV Instruction Manual.
01 .B6.30.0038                                                                                                                                                  B06.030.038 1-RPV-25-203-38                    OM-201-2271        PDI-UT-5    'UT          CS                  0.000 /6.500    40420    Reactor Vessel Closure Stud - Removed. Stud Class 1  B&W128723E                                                                                Length = 63.250. Reference OM-201-2271 RPV Instruction Manual.
O1.B6.30.0039.                                                                                                                                                  B06.030.039 1-RPV-25-203-65                    OM-201-2271        PDI-UT-5    UT          CS                  0.000 /6.500    40420    Reactor Vessel Closure Stud - Removed. Stud Class 1  B&W128723E                                                                                Length = 63.250. Reference OM-201-2271 RPV Instruction Manual.
011.B6.30.0040                                                                                                                                                  B06.030.040 1-RPV-25-203-40                    OM-201-2271        PDI-UT-5    UT          CS                  0.000 / 6500    40420    Reactor Vessel Closure Stud - Removed. Stud Class 1  B&W128723E                                                                                Length = 63.250. Reference OM-201-227-1 RPV Instruction Manual.
01 .B6.50.0002                                                                                                                                                  B06.050.002 1-RPV-WASH-BUSH                    OM-201-2271          NDE-62    VT-1        CS                  0.214 / 9.750            Reactor Vessel Closure Washers and Bushings.
Class 1  B&W128723E                                                                                Stud Holes 21 - 40. Reference OM-201-2271 RPV Instruction Manual.
Category      B-G-2 01 .B7.30.0001                                                                                                                                                  B07.030.001 1mSGA-UMW-STUDS                    OM-201.S-0001        NDE-62    VT-1        SS                  0.000 / 2.000            Steam Generator 1A Upper Head Manway Class 1  OM-201.S-0170                                                                              Studs and Nuts. (16 Studs & Nuts)
OM-201.S-0171                                                                              Examine all studs and nuts.
Stud Length =19.63 inches.
01 .B7.30.0005                                                                                                                                                  B07.030.005 1-SGA-UHHC-STUDS                  OM-201.S-0001        NDE-62    VT-i        SS                  0.000/1.250              Steam Generator 1A Upper Head Handhole Class 1  OM-201.S-0171                                                                              (primary) Cover Studs and Nuts OM-201.S-0252                                                                              (8 studs and nuts).
Examine all studs and nuts.
Stud length = 10.94 inches.
Printed 07/17/08 Ick8302 v. 01/19/08                                                      SDQA Cat "C"                        Oconee 1 7/17/2008 5:22:22 PM    Page 13 of 50
 
This report includes all change        pugh addendum ONSI-087 Oconee 1, 4th Interval, outage 3 (EOC-24)
Summary Num                                                    Insp Component ID / Type          System  ISO/DWG Numberrs    Procedure Req          Mat              Sched ThicWlDia    Cal Blocks Comments / HistoricalData Categor      B-G-2 101.137.50.000 01                                                                                                                                                      B07.050.001 1-PZR-RC4-STUDS                    OM-245-2012          NDE-62    VT-1          CS                  0.000 / 1.125            Pressurizer EMO Valve RC-4 Inlet Flange Studs Class 1                                                                                              . W-Z Quadrant. Connected to Valve 1RC-66. 8 Studs, Length = 8.750. Examine all studs and nuts.
Inspection in outage 1 is for additional sample and does not count in the percentages.
The additional sample inspection in outage 1 revealed heavy rust that would not allow a thorough examination of the sections of bolting between the flanges. The nuts and portions of the stud above and below the nuts were acceptable. An engineering evaluation was performed and concluded that the bolting was acceptable for service for several more fuel cycles.
The examination to be performed in outage 3 (EOC-24) will be performed by disassembling the flange and cleaning the bolting so that a thorough exam can be performed prior to any continued service.
01.B7.50.0002                                                                                                                                                          B07.050.002 1-PZR-RC66-STUDS                  OM-201-0591          NDE-62    VT-1          CS                  0.000 / 1.125            Pressurizer Relief Valve RC-66 Inlet Flange Class 1                                                                                              Bolting. W-Z Quadrant. 8 Studs and 16 Nuts, Length = 8.750. Examine all studs and nuts.
Inspection in outage 1 is for additional sample and does not count in the percentages.
01.B7.50.0003                                                                                                                                                          B07.050.003 1-PZR-RC67-STUDS                  OM-254-204            NDE-62    VT-1          CS                  0.000 I 1.125            Pressurizer Relief Valve RC-67 Inlet Flange Class 1 OM-254-205                                                                                    Bolting. W-X Quadrant. 8 Studs and 16 Nuts, Length = 8.750. Examine all studs and nuts.
Examination in outage 3 (1 EOC-24) is for additional sample per IWB-2430 (a) because a reportable indication was discovered during the examination of Summary Number 01 .B7.50.007 during 1EOC-24. The examination for this item does not count in the percentages for outage 3 (1EOC-24).
Printed 07/17/08 Ick8302 v. 01/19/08                                                        SDQA Cat "C"                        Oconee 1 7/17/2008 5:22:22 PM        Page 14 of 50
 
9                                      This report includes all change*          ugh addendum ONSI-087 Oconee 1, 4th Interval, outage 3 (EOC-24)
Summary Num                                                      Insp Component ID / Type          System  ISO/DWG Numbers    Procedure Req          Mat              Sched Thick/Dia    Cal Blocks Comments / HistoricalData Categor      B-G-2 01 .B7.50.0004                                                                                                                                                          B07.050:004 1-PZR-RC68-STUDS                  OM-254-204            NDE-62    VT-i        CS                  0.000 /1.125              Pressurizer Relief Valve RC-68 Inlet Flange Class 1  OM-254-205                                                                                    Bolting. X-Y Quadrant. 8 Studs and 16 Nuts, Length = 8.750. Examine all studs and nuts.
Examination in outage 3 (1 EOC-24) is for additional sample per IWB-2430 (a) because a reportable indication was discovered during the examination of Summary Number 01.B7.50.007 during 1EOC-24. The examination for this item does not count in the percentages for outage 3 (1 EOC-24).
01.B7.50.0005                                                                                                                                                          B07.050.005 1-51A-4-1A1-FLG              51A  1-51A-4                NDE-62    VT-1        CS                  1.000 /0.000              Flange Bolting on 2.5 inch piping flange located Class 1  0-ISIN4-101A-1.4                                                                              on the WA1  HPI line. Flange is located on weld iso 1-51A-4. Flange is located upstream of 1 inch drain valve 1HP-322.
01.B7.50.0006                                                                                                                                                          B07.050.006 1-51A-4-1A2-FLG              51A  1-51A-4                NDE-62    VT-1        CS                  1.000 / 0.000            Flange Bolting on 2.5 inch piping flange located Class 1  0-ISIN4-101A-1.4                                                                              on the 1A2 HPI line. Flange is located on weld iso 1-51A-4. Flange is located upstream of 1 inch valve 1HP-323.
01.B7.50.0007                                                                                                                                                          B07.050.007 1-51A-5-1B1-FLG              51A  1-51A-5                NDE-62    VT-1        CS                  1.000 /0.000              Flange Bolting on 2.5 inch piping flange located Class 1  0-ISIN4-101A-1.4                                                                              on the 161 HPI line. Flange is located on weld iso 1-51A-5.
01.B7.50.0008                                                                                                                                                          B07.050.008 1HP-255-1B2-FLG              51A  1HP-255                NDE-62    VT-1          CS                  1.000 / 0.000            Flange Bolting on 2.5 inch piping flange located Class 1  0-ISIN4-101A-1.4                                                                              on the 1B2 HPI line. Flange is located on weld iso 1HP-255.
01.B7.80.0001                                                                                                                                                          B07.080.001 1-RPV-CRD-HOUSING                  OM-201-2186            NDE-62    VT-1        CS                  0.000 / 1.250            CRD Housing includes Bolts (8 bolts on each Class 1  DPS 706599-1056                                                                              connection) and Housing Rings (1 pair per B&W152006E                                                                                    housing.)
Inspect only if disassembled.
Inspect only bolting that is to be reused.
Printed 07/17/08 Ick8302 v. 01/19/08                                                          SDQA Cat "C"                        Oconee 1 7/17/2008 5:22:22 PM        Page 15 of 50
 
This report includes all changes
* gh addendum ONS1-087 Oconee 1, 4th Interval, outage 3 (EOC-24)                                                                0 Summary Num                                                        Insp Component ID / Type          System  ISOIDWG Numbers        Procedure Req          Mat              Sched ThickWDia      Cal Blocks Comments / HistoricalData Categor      B-J 01.19.11.0025                                                                                                                                                              B09.011.033, 109.011.033A 1SGA-W2                        50  ISI-OCN1-008              NDE-25    MT          CS                    3.500 / 33.500            Steam Generator 1A Outlet Circumferential          Class 1  O-ISIN4-100A-1.1                                                                                  Nozzle to Pump 1A2 Suction Piping.
OM 201 .S--0033.001                                                                                Weld W2 is listed on OM 201.S--0033.001 but drawing ISI-OCN1-008 is listed as the iso to show where the weld is located on the 1A2 Suction Piping Loop.
Procedure NDE-600 uses the component for calibration. Procedure PDI-UT-1 may be used in lieu of NDE-600. If PDI-UT-1 is used, then the calibration block listed shall be used.
Terminal End Nozzle to Pipe 01.89.11.0025                                                                                                                                                              B09.011.033, B09.011.033A 1SGA-W2                        50  ISI-OCN1-008            NDE-600    UT          CS                    3.500 / 33.500 Component  Steam Generator 1A Outlet O-ISIN4-100A-1.1                                                                        50337    Nozzle to Pump 1A2 Suction Piping.
Circumferential          Class 1                                                                                                    Weld W2 is listed on OM 201.S--0033.001 but drawing ISI-OCN1-008 is listed as the iso to OM 201 .S--0033.001                                                                                show where the weld is located on the 1A2 Suction Piping Loop.
Procedure NDE-600 uses the component for calibration. Procedure PDI-UT-1 may be used in lieu of NDE-600. If PDI-UT-1 is used, then the calibration block listed shall be used.
Terminal End Nozzle to Pipe 01.89.11.0032                                                                                                                                                              B09.011.040, B09.011.040A 1-PSL-1                        50  ISI-OCN1-015              NDE-35    PT          SS          140      1.000 /10.750              Pressurizer Surge Piping. Elbow Pc. 80 to Circumferential          Class 1  O-ISIN4-100A-1.1                                                                                  Surge Nozzle Safe End Pc. 37.
Procedure NDE-600 uses the component for calibration. Procedure PDI-UT-2 may be used in lieu of NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used Stress Weld Elbow to Safe End 01.B9.11.0032                                                                                                                                                              B09.011.040, B09.011.040A 1-PSL-1                        50  ISI-OCN1-015            PDI-UT-2    UT          SS          140      1.000 / 10.750 Component  Pressurizer Surge Piping. Elbow Pc. 80 to O-ISIN4-100A-1.1                                                                        40399    Surge Nozzle Safe End Pc. 37.
PDI-UT-2-O  Procedure NDE-600 uses the component for Circumferential          Class 1                                                                                                    calibration. Procedure PDI-UT-2 may be used in lieu of NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used Stress Weld Printed 07/17/08 )ck8302 v. 01/19/08                                                            SDQA Cat "C"                          Oconee 1 7/17/2008 5:22:22 PM        Page 16 of 50
 
0                                      This report includes all change,,*        ugh addendum ONS1-087 Oconee 1, 4th Interval, outage 3 (EOC-24)
Summary Num                                                    Insp Component ID / Type.        System  ISOIDWG Numbers    Procedure Req          Mat              Sched Thick/Dia      Cal Blocks Comments / HistoricalData Catego      B-J Elbow to Safe End O1.B9.11.0048                                                                                                                                                            609.011.056, B09.011 .056A 1RC-289-8V                    50  ISI-OCN1-008          NDE-25    MT          CS                    3.500 /33.500              Weld 8V is listed on weld iso IRC-289 but Circumferential          Class 1  1RC-289                                                                                        drawing ISI-OCN1-008 is listed as the iso to show where the weld is located on the 1A2 Suction Piping Loop Procedure NDE-600 usesthe component for calibration. Procedure PDI-UT-1 may be used in lieu of NDE-600. If PDI-UT-1 is used, then the calibration block listed shall be used.
Stress Weld Pipe to Elbow 01..B9.11.0048                                                                                                                                                          B09.011.056, B09.011.056A 1RC-289-8V                    50  ISI-OCN1-008        NDE-600    UT          CS                    3.500 /33.500  Component  Weld 8V is listed on weld iso 1RC-289 but 1RC-289                                                                              50337    drawing ISI-OCN1-008 is listed as the iso to Circumferential          Class 1                                                                                                  show where the weld is located on the 1A2 Suction Piping Loop Procedure NDE-600 uses the component for calibration. Procedure PDI-UT-1 may be used in lieu of NDE-600. If PDI-UT-1 is used, then the calibration block listed shall be used.
Stress Weld Pipe to Elbow 01.89.11.0049                                                                                                                                                            B09.011.057, B09.011.057A 1-PIA2-4                      50 ISI-OCN1-008          NDE-25    MT          CS                    2.330 /33.500              Procedure NDE-600 uses the component for Circumferential          Class 1 OM-201-j1845                                                                                    calibration. Procedure PDI-UT-1 may be used in lieu of NDE-600. If PDI-UT-1 is used, then the calibration block listed shall be used.
Stress Weld Pipe to Elbow 01.19.11.0049                                                                                                                                                            B09.011.057, B09.011.057A 1-PIA2-4                      50  ISI-OCN1-008        NDE-600    UT          CS                    2.330 / 33.500 Component  Procedure NDE-600 uses the component for OM-201-1845                                                                          40350    calibration. Procedure PDI-UT-1 may be used in Circumferential          Class 1                                                                                                  lieu of NDE-600. If PDI-UT-1 is used, then the calibration block listed shall be used.
Stress Weld Pipeto Elbow Printed 07/17/08 Ick8302 v. 01/19/08                                                        SDQA Cat "C"                            Oconee 1 7/17/2008 5:22:22 PM        Page 17 of 50
 
This report includes all changes      tagh addendum ONS1-087 Oconee 1, 4th Interval, outage 3 (EOC-24)
Summary Num                                                    Insp Component ID / Type          System  ISO/DWG Numbers    Procedure Req          Mat              Sched Thick/Dia        Cal Blocks Comments / HistoricalData Catego        B-J 01..B9.111.0053                                                                                                                                                            B09.011.061, B09.011.061A 1-PIB2-9                        50  ISI-OCN1-010          NDE-35    PT          SS                    2.330 / 36.500                Procedure NDE-600 uses the component for Circumferential            Class 1  OM-201-1844                                                                                      calibration. Procedure PDI-UT-2 may be used in lieu of NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used. Procedure NDE-830 and Cal Block 50214 are to be used only for a supplemental UT performed from the pump side. The supplemental exam is being performed as requested by Jim McArdle which will be used to justify limited coverage from the code exam (performed using NDE-600 or PDI-UT-2).
Terminal End Pipe Safe End to RC Pump 1B2 01..B9.11.0053                                                                                                                                                            B09.011.061, B09.011.061A 1-PIB2-9                        50  ISI-OCN1-010        NDE-600    UT          SS                    2.330/36.500    Component  Procedure NDE-600 uses the component for OM-201-1844                                                                            40397    calibration. Procedure PDI-UT-2 may be used in 50214    lieu of NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used. Procedure Circumferential            Class 1                                                                                                  NDE-830 and Cal Block 50214 are to be used only for a supplemental UT performed from the pump side. The supplemental exam is being performed as requested by Jim McArdle which will be used to justify limited coverage from the code exam (performed using NDE-600 or PDI-UT-2).
Terminal End Pipe Safe End to RC Pump 1B2 01 .B9.11.0053                                                                                                                                                            B09.011.061, B09.011.061A 1-PIB2-9                        50  ISI-OCN1-010        NDE-830    UT          SS                    2.330 / 36.500  Component    Procedure NDE-600 uses the component for OM-201-1844                                                                            40397    calibration. Procedure PDI-UT-2 may be used in 50214    lieu of NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used. Procedure Circumferential            Class 1                                                                                                  NDE-830 and Cal Block 50214 are to be used only for a supplemental UT performed from the pump side. The supplemental exam is being performed as requested by Jim McArdle which will be used to justify limited coverage from the code exam (performed using NDE-600 or PDI-UT-2).
Terminal End Pipe Safe End to RC Pump 1B2 Oconee 1 7/17/2008 5:22:22 PM        Page 18 of 50 Printed  07/17/08 Ick8302 Printed 07/17/08          v. 01/19/08 1ck8302 v. 01/19/08                                                              Cat "C' SDQA Cat SDQA      "C"                            Oconee 1 7/17/2008 5:22:22 PM        Page 18 of 50
 
0 Summary Num This report includes all change*          ugh addendum ONS1-087 Oconee 1, 4th Interval, outage 3 (EOC-24)
Insp Component ID / Type          System  ISO/DWG Numbers    Procedure Req            Mat            Sched ThiclWDia    Cal Blocks Comments / HistoricalData Categor      B-J 01.1B9.11.0075                                                                                                                                                        B09.011.083, B09.011.083A 1-PD12-1                      50  ISI-OCN1-014          NDE-35    PT          SS                  2.333 / 33.500            Procedure NDE-600 uses the component for Circumferential          Class 1  OM-201-583                                                                                    calibration. Procedure PDI-UT-2 may be used in lieu of NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used. Procedure NDE-830 and Cal Block 50214 are to be used only for a supplemental UT performed from the pump side. The supplemental exam is being performed as requested by Jim McArdle which will be used to justify limited coverage from the code exam (performed using NDE-600 or PDI-UT-2).
Stress Weld Terminal End RC Pump 1B2 to Safe End 01 .B9.111.0075                                                                                                                                                        B09.011.083, B09.011.083A 1-PD1B2-1                      50  ISI-OCN1-014        NDE-830    UT          SS                  2.333 / 33.500 Component  Procedure NDE-600 uses the component for OM-201-583                                                                          40397    calibration. Procedure PDI-UT-2 may be used in 50214    lieu of NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used. Procedure Circumferential          Class 1                                                                                                NDE-830 and Cal Block 50214 are to be used only for a supplemental UT performed from the pump side. The supplemental exam is being performed as requested by Jim McArdle which will be used to justify limited coverage from the code exam (performed using NDE-600 or PDI-UT-2).
Stress Weld Terminal End RC Pump 1B2 to Safe End 01.B9.11.0075                                                                                                                                                          B09.011.083, B09.011.083A 1-PDB2-1                      50  ISI-OCN1-014        PDI-UT-2    UT          SS                  2.333/ 33.500  Component  Procedure NDE-600 uses the component for OM-201-583                                                                          40397    calibration. Procedure PDI-UT-2 may be used in 50214    lieu of NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used. Procedure Circumferential          Class 1 NDE-830 and Cal Block 50214 are to be used only for a supplemental UT performed from the pump side. The supplemental exam is being performed as requested by Jim McArdle which will be used to justify limited coverage from the code exam (performed using NDE-600 or PDI-UT-2).
Stress Weld Terminal End Printed 07/17/08 Ick8302 v. 01/19/08                                                        SDQA Cat "C"                          Oconee 1 7/17/2008 5:22:22 PM        Page 19 of 50
 
0                                      This report includes all change,      ugh addendum ONSI-087 Oconee 1, 4th Intervalutage3 (EOC-24)        -
Summary Num                                                    Insp Component ID / Type          System  ISOIDWG Numbers    Procedure Req            Mat          Sched Thick/Dia        Cal Blocks Comments / HistoricalData Cate-go      B-J 01.B9.11.0076                                                                                                                                                          B09.011.084, B09.011.084A 1-PDB2-3                      50  ISI-OCN1-014          NDE-25    MT          CS                  2.333 / 33.500              Procedure NDE-600 uses the component for Circumferential          Class 1  OM-201-1844                                                                                    calibration. Procedure PDI-UT-1 may be used in lieu of NDE-600. If PDI-UT-1 is used, then the calibration block listed shall be used.
Stress Weld Elbow 13 degree to Elbow 45 01.B9.11.0076                                                                                                                                                          B09.011.084, B09.01 1.084A 1-PDB2-3                      50  ISI-OCN1-014          PDI-UT-1    UT          CS                  2.333 / 33.500  Component  Procedure NDE-600 uses the component for OM-201-1844                                                                          40350    calibration. Procedure PDI-UT-1 may be used in Circumferential          Class 1                                                                                                lieu of NDE-600. If PDI-UT-1 is used, then the calibration block listed shall be used.
Stress Weld Elbow 13 degree to Elbow 45 01 .B9.11.0077                                                                                                                                                          B09.011.085, B09.011.085A 1-PDB2-4                      50  ISI-OCNI-014          NDE-25    MT          CS                  2.333 / 33.500              Procedure NDE-600 uses the component for Circumferential          Class 1  B&W 131914E6                                                                                  calibration. Procedure PDI-UT-1 may be used in lieu of NDE-600. If PDI-UT-I. is used, then the calibration block listed shall be used.
Stress Weld Elbow 45 to Pipe 45 01.B9.11.0077                                                                                                                                                          B09.011.085, B09.011.085A 1-PDB2-4                      50  ISI-OCN1-014          PDI-UT-1    UT          CS                  2.333 / 33.500  Component  Procedure NDE-600 uses the component for B&W 131914E6                                                                        40350    calibration. Procedure PDI-UT-1 may be used in Circumferential          Class 1                                                                                                lieu of NDE-600. If PDI-UT-1 is used, then the calibration block listed shall be used.
Stress Weld Elbow 45 to Pipe 45 01.B9.21.0009                                                                                                                                                            B09.021.009 1-51A-07-14E                  51A  1-51A-07(1)            NDE-35    PT          SS                    0.375/2.500 Circumferential          Class 1  0-ISIN4-100A-1.1 Pipe to Elbow Printed 07/17/08 Ick8302 v. 01/19/08                                                      SDQA Cat "C"                            Oconee 1 7/17/2008 5:22:22 PM        Page 20 of 50
 
This report includes all changes          ugh addendum ONS1-087 Oconee 1, 4th Interval, outage 3 (EOC-24)
Summary Num                                                        Insp Component ID / Type          System    ISOIDWG Number*s  Procedure Req            Mat              Sched Thick/Dia      Cal Blocks Comments / HistoricalData Category    B-J 01.B9.21.0010                                                                                                                                                              B09.021.010 1-51A-07-18E                  51A  1-51A-07(1)            NDE-35      PT          SS                    0.375 /2.500 Circumferential              Class 1  0-ISIN4-100A-1.1 Pipe to Elbow 01.B9.21.0011                                                                                                                                                              B09.021.011 1-51A-07-22E                  51A  1-51A-07(1)            NDE-35      PT.        SS                    0.375/2.500 Circumferential              Class 1  O-ISIN4-100A-1.1 Pipe to Elbow 45 01.B9.21.0015                                                                                                                                                              B09.021.015 1-51A-134A-6                  51A  1-51A-134A            NDE-35      PT          SS                    0.375 /2.500 Circumferential              Class 1  0-ISIN4-101A-1.1 Pipe to Reducer 01.89.21.0018                                                                                                                                                              B09.021.018 1-51A-137-1B                    51A  1-51A-137              NDE-35      PT          SS                    0.438 /3.000              Letdown Cooler 1B Outlet Channel Nozzle Pc. 5-Circumferential              Class 1  O-ISIN4-101A-1.1                                                                                to Elbow.
OM-201-2991 Terminal End Nozzle to Elbow 01.39.21.0019                                                                                                                                                            809.021.019 1-51A-137-27                    51A  1-51A-137              NDE-35      PT          SS                    0.344/2.000 Circumferential              Class 1  O-ISIN4-101A-1.1 Reducer to Pipe 01.139.21.0027                                                                                                                                                            1309.021.027 1-PIB2-11                      50  ISI-OCN1-010          NDE-35      PT    CS-Inconel                  0.816 / 3.500              Reactor Coolant Pump 182 Circumferential              Class 1  0-ISIN4-100A-1.1                                                                                Suction Piping. Drain Nozzle Pc. 64 to Safe OM-201-1845                                                                                      End Pc. 65.
Dissimilar Stress Weld Nozzle to Safe End Oconee 1 7/17/20085:22:22 PM      Page 21 of 50 Printed 07/17/08 Ick8302 Printed 07/17/08 1ck8302 01/19/08
: v. 01/19/08
: v.                                                                  SDQA  Cat "C" SDQA Cat    "C"                        Oconee 1 7/17/2008-5:22:22 PM      Page 21 of 50
 
This report includes all changes 9        ;h addendum ONS1-087 Oconee 1, 4th Intervaloutage 3 (EOC-24)
Summary Num                                                    Insp Component ID / Type          System  ISOIDWG Numbers    Procedure Req          Mat            Sched Thick/Dia      I0Blocks Comments / Historical Data Cate-go      B-J 01.B9.21.0032                                                                                                                                                        B09.021.032 1-PSP-4                        50  ISI-OCN1-016          NDE-35    PT          SS        160        0.375 / 2.875 Circumferential            Class 1 0-ISIN4-10OA-1.2 Stress Weld Reducer to Pipe 01.89.21.0157                                                                                                                                                        B09.021.012 1-51A-07-25E                  51A 1-51A-07(1)            NDE-35    PT          SS                    0.375/2.500 Circumferential            Class 1 O-ISIN 100A-1.1 Pipe to Elbow 01.B9.32.0006                                                                                                                                                        B09.032.006 1-PIB2-10                      50 ISI-OCN1-010            NDE-25    MT          CS                    2.250 /12.000            28" ID Pipe Pc. 63 to Drain Nozzle Pc. 64. The Branch                    Class 1 0-ISIN4-100A-1.1                                                                            NPS of the branch piping is 1.5 inches.
B&W 131918E6 Stress Weld Pipe to Nozzle 01.89.40.0015                                                                                                                                                        B09.040.015 1RC-127-3                      50 1RC-127                NDE-35    PT          SS          160        0.281 /1.500            Auxiliary Pressurizer Spray Line.
Circumferential            Class 1 0-ISIN4-10OA-1.2                                                                            This weld was previously listed as 1-50-127-3 and was shown on isometric 1-50-127.
Pipe to Full Coupling 01.89.40.0016                                                                                                                                                        B09.040.016 1RC-127-88A                    50 1RC-127                NDE-35    PT          SS          160        0.281 / 1.500          Auxiliary Pressurizer Spray Line.
Socket                    Class 1 0-ISIN4-100A-1.2                                                                            This weld was previously listed as 1-50-127-8BA and was shown on isometric 1-50-127.
Elbow to Pipe Catego      B-K 01.810.20.0002                                                                                                                                                      B10.020.006 1-51A-0-478A-H3C              51A 1-55-03/sht.4          NDE-35    PT          NA                    0.750 / 0.000          Calculation No. OSC-1660-11 , page 68 High Rigid Support              Class 1 0-ISIN4-101A-1.1                                                                            Pressure Injection. Inspect with F01.010.004.
Printed 07/17/08 Ick8302 v. 01/19/08                                                        SDQA Cat "C"                        Oconee 1 7/17/2008 5:22:22 PM        Page 22 of 50
 
01                                  This report includes all changes
* gh addendum ONS1-087 Oconee 1, 4th Interval, outage 3 (EOC-24)
Summary Num                                                    Insp Component ID / Type        System  ISO/DWG Numbers    Procedure Req            Mat              Sched Thick/Dia      CalBlocks Comments /Historical Data Categor      B-M-2 01 .B12M50.0003                                                                                                                                                        B12.050.003 1-53A-CF-1 3                  53A OM-245-0001            NDE-64    VT-3          SS                    0.000 / 14.000            B- Side Core Flood Valve Body 1CF-13 Internal Class I 0-lSIN4-102A-1.3                                                                                Surfaces. Y Axis.
Inspect one of the following valves: 1CF-11, 1CF-12, 1CF-13, or 1CF-14 only if valve is disassembled for maintenance, repair, or volumetric examination.
Cate-or      C-A O1 .Cl.30.0001                                                                                                                                                          C01.030.001 1-SGB-W69                      03 OM-201.S-0001        PDI-UT-6    UT          CS                    5.125 / 132.000  20T-240  Steam Generator 1B Upper Tubesheet to Shell Circumferential          Class 2 OM-201.S-0157                                                                                  Can # 4.
Tubesheet to Shell O1.Cl.30.0007                                                                                                                                                          C01.030.003 1-RCSRCA-SH-TS-1              51A OM 201-086            NDE-35    PT          SS                      0.165 / 0.000            Reactor Coolant Seal Return Cooler 1A. Weld Circumferential          Class 2 O-ISIN4-101A-1.1                                                                                located next to inlet piping.
OM 201-3218 Shell to Tubesheet 01 C1 .30.0008                                                                                                                                                          C01.030.004 1-RCSRCA-SH-TS-2              51A OM 201-086            NDE-35    PT          SS                      0.165 / 0.000            Reactor Coolant Seal Return Cooler 1A. Weld Circumferential          Class 2 O-ISIN4-101A-1.1                                                                                located next to outlet piping.
OM 201-3218 Shell to Tubesheet Catego.y      C-C O1 .C3.10.0001                                                                                                                                                          C03.010.009 1-RCSR-COOLER-A              51B OM-201-0086            NDE-35    PT          SS                      0.187 /0.000            Reactor Coolant Seal Return Cooler 1A. (2 Class 2 O-ISIN4-101A-1.1                                                                                Support Legs) Only 1 Welded Attachment Required to be Examined, Inspector shall specify which attachment was examined for future interval reference. Item rescheduled as a result of PIP 0-06-4249. Item added to Outage 2 as an additional exam per IWC-2430 (a).
Reference PIP 0-06-7569.
Plate to Shell O1 .C3.20.0002                                                                                                                                                          C03.020.002 1-01A-0-550-R7                01A 1-01-01/sht.1          NDE-25    MT          NA                      1.000 /0.000            Calculation No. OSC-320, page 131.1. Inspect Mech Snubber              Class 2 O-ISIN4-122A-1.1                                                                                with F01.022.006.
Printed 07/17/08 Ick8302 v. 01/19/08                                                        SDQA Cat "C"                            Oconee 1 7/17/2008 5:22:22 PM        Page 23 of 50
 
This report includes all changeQugh addendum ONS1-087 Oconee 1, 4th Interval, outage 3 (EOC-24)
Summary Num                                                      Insp Component lD / Type        . System  ISOIDWG Numbers    Procedure Req            Mat            Sched Thick/Dia    'al Blocks Comments / HistoricalData Category      C.C O1 .C3.20.0013                                                                                                                                                        C03.020.052 1-51-0-436H-SR17                51  1-51-01/sht.2          NDE-35      PT          NA                  0.750 / 0.000            Calculation No. OSC-400, page 51. Inspect with Rigid Restraint          Class 2  0-ISIN4-101A-1.2                                                                              F01.021.054.
O-lAB-15101-02 O1 .C3.20.0022                                                                                                                                                        C03.020.096 1-53B-5-0-444-H6              53B  1-53-02/sht.2          NDE-35    PT          NA                  1.000 / 0.000            Calculation No. OSC-408. Inspect with Rigid Support            Class 2  0-ISIN4-102A-1.2                                                                              F01.020.099.
O-lAB-15302-02 O1 .C3.20.0023                                                                                                                                                        C03.020.1 01 1-54A-0-439A-R16              54A  1-54-03/sht.1          NDE-35    PT          NA                  1.000 /0.000              Calculation No. OSC-416, page 58.1.
Mech Snubber              Class 2  0-ISIN4-103A-1.1 O1.C3.20.0025                                                                                                                                                        C03.020.103 1-54A-3-0-436D-R27            54A  1-54-01/sht.1          NDE-35    PT          NA                  1.000 /0.000              Calculation No. OSC-1628, page 60.
Rigid Support            Class 2  0-ISIN4-103A-1.1 O1 .C3.20.0026                                                                                                                                                        C03.020.104 1-54A-3-0-439A-R1 1            54A  1-54-03/sht.1          NDE-35    PT          NA                  1.000 / 0.000            Calculation No. OSC-416, page 58.1. Inspect Rigid Restraint          Class 2  0-ISIN4-103A-1.1                                                                              with F01.021.102.
O0 .C3.20.0029                                                                                                                                                        C03.020.121 1-56-4-0-437B-H1                56  4-56-02/sht.3          NDE-35    PT          NA                  0.125 / 0.000            Calculation No. OSC-421, page 95.1. Inspect Rigid Support            Class 2  0-ISIN4-102A-1.1                                                                              with F01.020.131.
O1 .C3.20.0222                                                                                                                                                        C03.020.015 1-03A-4-PEN # 50              03A  1-03A-4 (1)            NDE-35    PT          CS                  0.750 /8.000              O-1RB-103A14-01, Problem No. 1-03A-14, Rigid Restraint          Class 2  0-62A                                                                                        Drawing 0-ISIN4-121D-1.1. Type II Penetration 0-62C                                                                                        located on Reactor Bid side of Penetration # 50.
Perform a surface exam on the Penetration Pipe Cap and reinforcement plate attachment weld to the 6 inch, System 03A, piping which goes through Penetration # 50. SeeDetail 5 on drawing O-62C.
Printed 07/17/08 Ick8302 v. 01/19/08                                                          SDQA Cat "C"                          Oconee 1 7/17/2008 5:22:22 PM      Page 24 of 50
 
101                                      This report includes all changesugh addendum ONS1-087 Oconee 1, 4th Interval, outage 3 (EOC-24)
Summary Num Insp Component ID / Type          System    ISO/DWG Numbers    Procedure Req            Mat            Sched Thick/Dia      Cal Blocks Comments / HistoricalData Categor      C-C O1.C3.20.0225                                                                                                                                                                  C03.020.122 lSF-107-PEN # 56                56    1SF-107                NDE-35    PT          CS                    0.750 /8.000              O-1RB-15307-04, Problem No 1-53-07. Drawing Rigid Restraint            Class 2  0-62A                                                                                            0-ISIN4-104A-1.1. Type I Penetration located O-62C                                                                                            on Reactor Bid side of Penetration # 56.
Perform a surface exam on the Penetration Pipe Cap and reinforcement plate attachment weld to the 8 inch, System 56, piping which goes through Penetration # 56. see Detail 5 on drawing 0-62C.
Categor      C-F-1 O1 .C5.11.0027                                                                                                                                                              C05.011.005, C05.011.005A 1LP-124-21                    53A    1LP-124                NDE-35    PT          SS                    1.168 / 12.000            Procedure NDE-600 uses the component for Circumferential            Class 2  0-ISIN4-102A-1.2                                                                                calibration. Procedure PDI-UT-2 may be used in lieu of NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used.
Reducer to Valve 1LP-1 7 O1.C5.11.0027                                                                                                                                                                C05.011.005, C05.011.005A 1LP-124-21                    53A    1Lp-124              NDE-600    UT          SS                    1.168 / 12.000 Component  Procedure NDE-600 uses the component for 0-ISIN4-102A-1.2                                                                        40413    calibration. Procedure PDI-UT-2 may be used in Circumferential            Class 2                                                                                                    lieu of NDE-600. If PDI-UT-2 is Used, then the calibration block listed shall be used.
Reducer to Valve 1LP-17 O1.C5.11.0068                                                                                                                                                                C05.011.046, C05.011.046A 1LP-208-12                    53A    1LP-208                NDE-35    PT          SS                    1.000 /10.000              Procedure NDE-600 uses the component for Circumferential            Class 2  0-ISIN4-102A-1.3                                                                                  calibration. Procedure PDI-UT-2 may be used in lieu of NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used.
Pipe to Elbow O1.C5.11.0068                                                                                                                                                                C05.011.046, C05.011.046A 1LP-208-12                    53A    1LP-208              PDI-UT-2    UT          SS                    1.000 / 10.000 Component  Procedure NDE-600 uses the component for 0-ISIN4-102A-1.3                                                                      PDI-UT-2-0  calibration. Procedure PDI-UT-2 may be used in Circumferential            Class 2                                                                                                    lieu of NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used.
Pipe to Elbow Oconee 1 7/17/2008 5:22:22 PM        Page 25 of 50 Printed 07/17/08 Ick8302 Printed 07/17/08 1ck8302 01/19/08
: v. 01/19108
: v.                                                                    SDQA Cat SDQA    Cat "C" "C"                          Oconee 1 7/17/2008 5:22:22 PM        Page 25 of 50
 
This report includes all changes
* gh addendum ONS1-087 Oconee 1, 4th Interval,*  age 3 (EOC-24)
Summary Num                                                      Insp Component ID / Type        System    ISOIDWG Numbers    Procedure Req          Mat              Sched Thick/Dia        Cal Blocks Comments / HistoricalData Categor      C-F-1 O1 .C5.11.0069                                                                                                                                                                C05.011.047, C05.011.047A 1LP-208-13                    53A 1LP-208                  NDE-35    PT          SS                    1.000 / 10.000 .            Procedure NDE-600 uses the component for Circumferential            Class 2 0-ISIN4-102A-1.3                                                                                    calibration. Procedure PDI-UT-2 may be used in lieu of NDE-600. IfPDI-UT-2 is used, then the calibration block listed shall be used.
Pipe to Elbow O1 .C5.11.0069                                                                                                                                                                C05.011.047, C05.011.047A 1LP-208-13                    53A  1LP-208              PDI-UT-2    UT          SS                    1.000 /10.000    Component  Procedure NDE-600 uses the component for 0-ISIN4-102A-1.3                                                                      PDI-UT-2-0  calibration. Procedure PDI-UT-2 may be used in Circumferential    n    Class  2 Ccalibration                                                                                                lieu of NDE-600. IfPDI-UT-2 is used, then the block listed shall be used.
Pipe to Elbow O1 .C5.11.0070                                                                                                                                                                C05.011.048, C05.011.048A 1LP-208-14                    53A 1LP-208                  NDE-35    PT          SS                    1.000 / 10.000              Procedure NDE-600 uses the component for Circumferential            Class 2 0-ISIN4-102A-1.3                                                                                    calibration. Procedure PDI-UT-2 may be used in lieu of NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used.
Pipe to Elbow O1 .C5.11.0070                                                                                                                                                                C05.011.048, C05.011.048A 1LP-208-14                    53A  1LP-208              PDI-UT-2    UT          SS                    1.000 /10.000    Component  Procedure NDE-600 uses the component for 0-ISIN4-102A-1.3                                                                      PDI-UT-2-0  calibration. Procedure PDI-UT-2 may be used in Circumferential            Class 2                                                                                                      lieu of NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used.
Pipe to Elbow O1.C5.11.0071                                                                                                                                                                C05.011.049, C05.011.049A 1LP-208-15                    53A 1LP-208                  NDE-35    PT          SS                    1.000 / 10.000              Procedure NDE-600 uses the component for Circumferential            Class 2 0-ISIN4-102A-1.3                                                                                    calibration. Procedure PDI-UT-2 may be used in lieu of NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used.
Pipe to Elbow O1 .C5.11.0071                                                                                                                                                                C05.011.049, C05.011.049A
  *1LP-208-15                    53A  1LP-208              PDI-UT-2    UT          SS                    1.000/ 10.000    Component  Procedure NDE-600 uses the component for 0-ISIN4-102A-1.3                                                                      PDI-UT-2-0  calibration. Procedure PDI-UT-2 may be used in Circumferential            Class 2                                                                                                      lieu of NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used.
Pipe to Elbow Printed 07/17/08 Ick8302 v. 01/19/08                                                          SDQA Cat "C"                              Oconee 1 7/17/2008 5:22:22 PM        Page 26 of 50
 
This report includes all changes0 ugh addendum ONS1-087 Oconee 1, 4th Interval, outage 3 (EOC-24)                                                                0 Summary Num                                                    Insp Component ID Type            System  ISO/DWG Numbers    Procedure Req          Mat              Sched ThickWDia      Cal Blocks Comments / HistoricalData Cate-o        C-F-I O1.C5.11.0072                                                                                                                                                            C05.011.050, C05.011.050A 1LP-208-19                    53A  1LP-208                NDE-35    PT          SS                    1.000 / 10.000            Procedure NDE-600 uses the component for Circumferential            Class 2 0-ISIN4-102A-1.3                                                                                calibration. Procedure PDI-UT-2 may be used in lieu of NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used.
Pipe to Valve 1LP-1 79 O1.C5.11.0072                                                                                                                                                            C05.011.050, C05.011.050A 1 LP-208-19                  53A  1LP-208              PDI-UT-2    UT          SS                    1.000 / 10.000 Component  Procedure NDE-600 uses the component for 0-ISIN4-102A-1.3                                                                    PDI-UT-2-0  calibration. Procedure PDI-UT-2 may be used in Circumferential            Class 2                                                                                                  lieu of NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used.
Pipe to Valve 1LP-179 O1.C5.11.0073                                                                                                                                                            C05.011.051, C05.011.051A 1LP-208-2                    53A  1LP-208                NDE-35    PT          SS                    1.000 / 10.000            Procedure NDE-600 uses the component for Circumferential            Class 2 0-ISIN4-102A-1.3                                                                                calibration. Procedure PDI-UT-2 may be used in lieu of NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used.
Pipe to Elbow O1.C5.11.0073                                                                                                                                                            C05.011.051, C05.011.051A 1LP-208-2                    53A  1LP-208              PDI-UT-2    UT          SS                    1.000  10.000 Component  Procedure NDE-600 uses the component for 0-ISIN4-102A-1.3                                                                    PDI-UT-2-0  calibration. Procedure PDI-UT-2 may be used in Circumferential            Class 2                                                                                                  lieu of NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used.
Pipe to Elbow O1.C5.11.0074                                                                                                                                                            C05.011.052, C05.011.052A 1LP-208-20                    53A  1LP-208                NDE-35    PT          SS                    1.000 / 10.000            Procedure NDE-600 uses the component for Circumferential            Class 2 0-ISIN4-102A-1.3                                                                                calibration. Procedure PDI-UT-2 may be used in lieu of NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used.
Pipe to Valve 1LP-179 O1.C5.11.0074                                                                                                                                                            C05.011.052, C05.011.052A 1LP-208-20                    53A  1LP-208              PDI-UT-2    UT          SS                    1.000 / 10.000 Component  Procedure NDE-600 uses the component for 0-ISIN4-102A-1.3                                                                    PDI-UT-2-0  calibration. Procedure PDI-UT-2 may be used in Circumferential            Class 2                                                                                                  lieu of NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used.
Pipe to Valve 1LP-179 Printed 07/17/08 Ick8302 v. 01/19/08                                                        SDQA Cat "C"                            Oconee 1 7/17/2008 5:22:22 PM        Page 27 of 50
 
This report includes all changes          Jgh addendum ONSl-087 Oconee 1, 4th Interval, outage 3 (EOC-24)
Summary Num                                                    Insp Component ID / Type          System  ISO/DWG Numbers    Procedure Req          Mat              Sched ThiclWDia      Cal Blocks Comments / HistoricalData Cate-go      C-F-1 O1.C5.11.0075                                                                                                                                                            C05.011.053, C05.011.053A 1LP-208-3                    53A  1LP-208                NDE-35    PT          SS                    1.000 / 10.000            Procedure NDE-600 uses the component for Circumferential          Class 2  0-ISIN4-102A-1.3                                                                                calibration. Procedure PDI-UT-2 may be used in lieu of NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used.
Pipe to Valve 1LP-178 O1.C5.11.0075                                                                                                                                                            C05.011.053, C05.011.053A 1LP-208-3                    53A  1LP-208              PDI-UT-2    UT          SS                    1.000 / 10.000 Component  Procedure NDE-600 uses the component for O-ISIN4-102A-1.3                                                                    PDI-UT-2-0  calibration. Procedure PDI-UT-2 may be used in Circumferential          Class 2                                                                                                  lieu of NDE-600. If PDI-UT-2is used, then the calibration block listed shall be used.
Pipe to Valve 1LP-178 O1.C5.11.0076                                                                                                                                                            (C05.011.054, C05.011.054A 1LP-208-4                    53A  1LP-208                NDE-35    PT          SS                    1.000 / 10.000            Procedure NDE-600 uses the component for Circumferential          Class 2  0-ISIN4-102A-1.3                                                                                calibration. Procedure PDI-UT-2 may be used in lieu of NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used.
Pipe to Valve 1LP-178 O1.C5.11.0076                                                                                                                                                            C05.011.054, C05.011.054A 1LP-208-4                    53A  1LP-208              PDI-UT-2    UT          SS                    1.000 / 10.000 Component  Procedure NDE-600 uses the component for 0-ISIN4-102A-1.3                                                                    PDI-UT-2-0  calibration. Procedure PDI-UT-2 may be used in Circumferential          Class 2                                                                                                  lieu of NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used.
Pipe to Valve 1LP-178 O1.C5.11.0077                                                                                                                                                            C05.011.055, C05.011.055A 1LP-208-5                    53A  1LP-208                NDE-35    PT          SS                    1.000 /10.000              Procedure NDE-600 uses the component for Circumferential          Class 2  0-ISIN4-102A-1.3                                                                                calibration. Procedure PDI-UT-2 may be used in lieu of NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used.
Pipe to Elbow O1.C5.11.0077                                                                                                                                                            C05.011.055, C05.011.055A 1LP-208-5                    53A  1LP-208              PDI-UT-2    UT          SS                    1.000 / 10.000 Component  Procedure NDE-600 uses the component for O-ISIN4-102A-1.3                                                                    PDI-UT-2-0  calibration. Procedure PDI-UT-2 may be used in Circumferential          Class 2                                                                                                  lieu of NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used.
Pipe to Elbow Printed 07/17/08 1ck8302 v. 01/19/08                                                          SDQA Cat "C"                            Oconee 1 7/17/2008 5:22:22 PM        Page 28 of 50
 
This report includes all changes-ough addendum ONS1-087 Oconee 1, 4th Interval, outage 3 (EOC-24)                                                                S Summary Num                                                    Insp Component ID / Type          System  ISO/DWG Numbers    Procedure Req          Mat              Sched Thick/Dia      Cal Blocks Comments / HistoricalData Cate-gory    C-F-O1.C5.11.0078                                                                                                                                                            C05.011.056, C05.011.056A 1LP-208-6                    53A  1LP-208                NDE-35    PT          SS                    1.000 /10.000              Procedure NDE-600 uses the component for Circumferential          Class 2  0-ISIN4-102A-1.3                                                                                calibration. Procedure PDI-UT-2 may be used in lieu of NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used.
Pipe to Elbow O1 .C5.11.0078                                                                                                                                                            C05.011.056, C05.011.056A 1LP-208-6                    53A  1LP-208              PDI-UT-2    UT          SS                    1.000 /10.000  Component  Procedure NDE-600 uses the component for 0-ISIN4-102A-1.3                                                                    PDI-UT-2-0  calibration. Procedure PDI-UT-2 may be used in Circumferential          Class 2                                                                                                  lieu of NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used.
Pipe to Elbow O1.C5.11.0079                                                                                                                                                            C05.011.057, C05.011.057A 1LP-208-7                    53A  1LP-208                NDE-35    PT          SS                    1.000 /10.000              Procedure NDE-600 uses the component for Circumferential          Class 2  0-ISIN4-102A-1.3                                                                                calibration. Procedure PDI-UT-2 may be used in lieu of NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used.
Pipe to Elbow O1.C5.11.0079                                                                                                                                                            C05.011.057, C05.011.057A 1LP-208-7                    53A  1LP-208              PDI-UT-2    UT          SS                    1.000 /10.000  Component- Procedure NDE-600 uses the component for 0-ISIN4-102A-1.3                                                                    PDI-UT-2-O calibration. Procedure PDI-UT-2 may be used in Circumferential          Class 2                                                                                                  lieu of NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used.
Pipe to Elbow O1.C5.11.0080                                                                                                                                                            C05.011.058, C05.011.058A 1LP-208-8                    53A  1LP-208                NDE-35    PT          SS                    1.000 / 10.000            Procedure NDE-600 uses the component for Circumferential          Class 2  0-ISIN4-102A-1.3                                                                                calibration. Procedure PDI-UT-2 may be used in lieu of NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used.
Pipe to Elbow O1.C5.11.0080                                                                                                                                                            C05.011.058, C05.011.058A 1LP-208-8                    53A  1LP-208              PDI-UT-2    UT          SS                    1.000 10.000  Component  Procedure NDE-600 uses the component for 0-ISIN4-102A-1.3                                                                    PDI-UT-2-0  calibration. Procedure PDI-UT-2 may be used in Circumferential          Class 2                                                                                                  lieu of NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used.
Pipe to Elbow Printed 07/17/08 Ick8302 v. 01/19/08                                                        SDQA Cat "C"                            Oconee 1 7/17/2008 5:22:22 PM        Page 29 of 50
 
This report includes all change*        ugh addendum ONSI-087 Oconee 1, 4th Interval,outage 3 (EOC-24)
Summary Num                                                    Insp Component ID / Type          System  ISOIDWG Numbe,r    Procedure Req            Mat            Sched Thick/Dia      'al Blocks Comments / HistoricalData Catego        C-p-I O1.C5.21.0003                                                                                                                                                            C05.021.003, C05.021.003A 1-51A-03-93BA                51A  1-51A-03(1)            NDE-35    PT          SS                    0.531 / 4.000              Procedure NDE-600 uses the component for Circumferential            Class 2 0-ISIN4-101A-1.4                                                                                calibration. Procedure PDI-UT-2 may be used in lieu of NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used.
Pipe to Elbow O1 .C5.21.0003                                                                                                                                                            C05.021.003, C05.021.003A 1-51A-03-93BA                51A  1-51A-03(1)          NDE-600    UT          SS                    0.531 /4.000  Component    Procedure NDE-600 uses the component for O-ISIN4-101A-1.4                                                                      40406      calibration. Procedure PDI-UT-2 may be used in Circumferential            Class 2                                                                                                . lieu of NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used.
Pipe to Elbow O1.C5.21.0007                                                                                                                                                            C05.021.009, C05.021.009A 1HP-192-4                    51A  1HP-192                NDE-35    PT          SS                    0.531 /4.000                Procedure NDE-600 uses the component for Circumferential          Class 2  0-ISIN4-101A-1.4                                                                                calibration. Procedure PDI-UT-2 may be used in lieu of NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used.
Pipe to Elbow O1 .C5.21.0007                                                                                                                                                            C05.021.009, C05.021.009A 1HP-192-4                    51A  1HP-192              PDI-UT-2    UT          SS                    0.531 /4.000  Component    Procedure NDE-600 uses the component for 0-ISIN4-101A-1.4                                                                  PDI-UT-2-0    calibration. Procedure PDI-UT-2 may be used in Circumferential          Class 2                                                                                                  lieu of NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used.
Pipe to Elbow O1 .C5.21.0009                                                                                                                                                            C05.021.014, C05.021.014A 1-51A-124-2                  51A  1-51A-124              NDE-35    PT          SS                    0.531 /4.000                Procedure NDE-600 uses the component for Circumferential          Class 2  0-ISIN4-101A-1.3                                                                                calibration. Procedure PDI-UT-2 may be used in lieu of NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used.
Elbow to Pipe O1 .C5.21.0009                                                                                                                                                            C05.021.014, C05.021.014A 1-51A-124-2                  51A  1-51A-124            PDI-UT-2    UT          SS                    0.531 /4.000  Component    Procedure NDE-600 uses the component for 0-ISIN4-101A-1.3                                                                  PDI-UT-2-0    calibration. Procedure PDI-UT-2 may be used in Circumferential          Class 2                                                                                                  lieu of NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used.
Elbow to Pipe Printed 07/17/08 Ick8302 v. 01/19/08                                                        SDQA Cat "C"                            Oconee 1 7/17/2008 5:22:22 PM          Page 30 of 50
 
This report includes all changes thih        addendum ONSI-087 Oconee 1, 4th Interval, oage 3 (EOC-24)
Summary Num                                                      Insp Component ID / Type          System  ISO/DWG Numbe rs    Procedure Req          Mat              Sched Thick/Dia      ;al Blocks Comments / HistoricalData Cate-go      C-F-1 O1.C5.21.0019                                                                                                                                                            C05.021.036, C05.021.036A 1HP-180-97E                  51A  1HP-180                NDE-35      PT        SS                    0.375 /2.500              Procedure NDE-600 uses the component for.
Circumferential            Class 2 0-ISIN4-101A-1.1                                                                                calibration. Procedure PDI-UT-2 may be used in lieu of NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used.
Elbow to Pipe O1.C5.21.0019                                                                                                                                                            C05.021.036, C05.021.036A 1HP-180-97E                  51A  1HP-180              PDI-UT-2  . UT        SS                    0.375 /2.500  Component    Procedure NDE-600 uses the component for 0-ISIN4-101A-1.1                                                                      40378    calibration. Procedure PDI-UT-2 may be used in PDI-UT-2-0  lieu of NDE-600. If PDI-UT-2 is used, then the Circumferential            Class 2                                                                                                  calibration block listed shall be used.
Elbow to Pipe O1 .C5.21.0023                                                                                                                                                            C05.021.041, C05.021.041A 1HP-282-76A                  51A  1HP-282                NDE-35      PT        SS                    0.531 /4.000              Procedure NDE-600 uses the component for Circumferential          Class 2  0-ISIN4-101A-1.3                                                                                calibration. Procedure PDI-UT-2 may be used in lieu of NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used.
Tee to Valve 1HP-117 O1 .C5.21.0023                                                                                                                                                            C05.021.041, C05.021.041A iHP-282-76A                  51A  1HP-282              NDE-600      UT        SS                    0.531 / 4.000 Component    Procedure NDE-600 uses the component for 0-ISIN4-101A-1.3                                                                      40406    calibration. Procedure PDI-UT-2 may be used in Circumferential          Class 2                                                                                                  lieu of NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used.
Tee to Valve 1HP-117 O1.C5.21.0032                                                                                                                                                            C05.021.053, C05.021.053A 1-51A-02-64B                  51A  1-51A-02              NDE-35      PT        SS                    0.531 / 4.000              Procedure NDE-600 uses the component foe Circumferential          Class 2  0-ISIN4-101A-1.3                                                                                calibration. Procedure PDI-UT-2 may be used in lieu of NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used.
Elbow to Elbow O1.C5.21.0032                                                                                                                                                            C05.021.053, C05.021.053A 1-51A-02-64B                  51A  1-51A-02              PDI-UT-2      UT        SS                    0.531 / 4.000 Component    Procedure NDE-600 uses the component for 0-ISIN4-101A-1.3                                                                    PDI-UT-2-0  calibration. Procedure PDI-UT-2 may be used in Circumferential          Class 2                                                                                                  lieu of NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used.
Elbow to Elbow Printed 07/17/08 Ick8302 v. 01/19/08                                                          SDQA Cat "C"                            Oconee 1 7/17/2008 5:22:22 PM        Page 31 of 50
 
This report includes all change
* ugh addendum ONS1-087 01.
Oconee 1, 4th Interval, outage 3 (EOC-24)
Summary Num                                                    Insp Component ID / Type          System  ISOIDWG Numbers    Procedure Req          Mat              Sched Thick/Dia      Cal Blocks Comments / HistoricalData CateqorV    C-F-1 O1.C5.21.0036                                                                                                                                                          C05.021.057, C05.021.057A 1-51A-03-93BB                51A  1-51A-03(1)            NDE-35    PT          SS                    0.531 /4.000              Procedure NDE-600 uses the component for Circumferential            Class 2 0-ISIN4-101A-1.4                                                                              calibration. Procedure PDI-UT-2 may be used in lieuof NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used.
Elbow to Pipe O1 .C5.21.0036                                                                                                                                                          C05.021.057, C05.021.057A 1-51A-03-93BB                51A  1-51A-03(1)          NDE-600    UT          SS                    0.531 /4.000  Component  Procedure NDE-600 uses the component for 0-ISIN4-101A-1.4                                                                    40406    calibration. Procedure PDI-UT-2 may be used in Circumferential          Class 2                                                                                                lieu of NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used.
Elbow to Pipe O1.C5.21.0039                                                                                                                                                          C05.021.063, C05.021.063A 1HP-193-13                    51A  1HP-193                NDE-35    PT          SS                    0.674 /4.000              Procedure NDE-600 uses the component for Circumferential          Class 2  0-ISIN4-101A-1.4                                                                              calibration. Procedure PDI-UT-2 may be used in lieu of NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used.
Valve 1HP-26 to Tee O1 .C5.21.0039                                                                                                                                                          C05.021.063, C05.021.063A 1HP-193-13                    51A  1HP-193              NDE-600    UT          SS                    0.674 / 4.000 Component  Procedure NDE-600 uses the component for 0-ISIN4-101A-1.4                                                                  PDI-UT-2-0  calibration. Procedure PDI-UT-2 may be used in Circumferential          Class 2                                                                                                lieu of NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used.
Valve 1HP-26 to Tee O1 .C5.21.0043                                                                                                                                                          C05.021.069, C05.021.069A 1HP-367-21                    51B  1HP-367                NDE-35    PT          SS                    0.216/ 3.000              Procedure NDE-600 uses the component for Circumferential          Class 2  0-ISIN4-101A-1.1                                                                              calibration. Procedure PDI-UT-2 may be used in lieu of NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used.
Elbow to Flange O1.C5.21.0043                                                                                                                                                          C05.021.069, C05.021.069A 1HP-367-21                    51B  1HP-367              NDE-600    UT          SS                    0.216 / 3.000 Component  Procedure NDE-600 uses the component for 0-ISIN4-101A-1.1                                                                  PDI-UT-2-0  calibration. Procedure PDI-UT-2 may be used in Circumferential          Class 2                                                                                                lieu of NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used.
Elbow to Flange Printed 07/17/08 Ick8302 v. 01/19/08                                                        SDQA Cat "C"                          Oconee 1 7/17/2008 5:22:22 PM        Page 32 of 50
 
This report includes all changes t        gh addendum ONS1-087 Oconee 1, 4th Interval, outage 3 (EOC-24)
Summary Num                                                      Insp Component ID / Type          System  ISO/DWG Numbers    Procedure Req            Mat              Sched Thick/Dia      Cal Blocks Comments / HistoricalData Category    C-F-j O1.C5.21.0047                                                                                                                                                              C05.021.077, C05.021.077A 1-51A-01-27A                  51A  1-51A-01(1)            NDE-35      PT          SS                    0.237 /4.000                Procedure NDE-600 uses the component for Circumferential            Class 2  0-ISIN4-101A-1.3                                                                                  calibration. Procedure PDI-UT-2 may be used in lieu of NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used.
Elbow to Elbow O1.C5.21.0047                                                                                                                                                              C05.021.077, C05.021.077A 1-51A-01-27A                  51A  1-51A-01(1)          NDE-600    UT          SS                    0.237 /4.000  Component    Procedure NDE-600 uses the component for 0-ISIN4-101A-1.3                                                                  - PDI UT 2-0  calibration. Procedure PDI-UT-2 may be used in Circumferential            Class 2                                                                                                    lieu of NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used.
Elbow to Elbow O1.C5.21.0052                                                                                                                                                              C05.021.089, C05.021.089A 1-51A-02-30B                  51A  1-51A-02              NDE-35    PT          SS                    0.531 /4.000                Procedure NDE-600 uses the component for Circumferential            Class 2  0-ISIN4-101A-1.4                                                                                  calibration. Procedure PDI-UT-2 may be used in lieu of NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used.
Tee to Pipe O1.C5.21.0052                                                                                                                                                              C05.021.089, C05.021.089A 1-51A-02-30B                  51A  1-51A-02              PDI-UT-2    UT          SS                    0.531 /4.000  Component    Procedure NDE-600 uses the component for 0-ISIN4-101A-1.4                                                                    PDI-UT-2-0  calibration. Procedure PDI-UT-2 may be used in Circumferential            Class 2                                                                                                    lieu of NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used.
Tee to Pipe O1.C5.30.0002                                                                                                                                                                C05.030.002 1-51B-10-49                    51B  1-51B-10              NDE-35      PT          SS                    0.154 /2.000 Socket                    Class 2  0-ISIN4-101A-1.1 Pipe to Valve 1HP21 O1.C5.30.0005                                                                                                                                                                C05.030.005 1-51A-136-27                  51A  1-51A-136              NDE-35    PT          SS                      0.344/2.000 Socket                    Class 2  0-ISIN4-101A-1.1 Pipe to Elbow Printed 07/17/08 Ick8302 v. 01/19/08                                                          SDQA Cat "C"                            Oconee 1 7/17/2008 5:22:22 PM        Page 33 of 50
 
This report includes all change~ugh addendum ONS1-087 Oconee 1, 4th Interval, outage 3 (EOC-24)
Summary Num                                                    Insp Component ID / Type        System  ISO/DWG Numberrs    Procedure Req          Mat              Sched Thick/Dia      C*al Blocks Comments / HistoricalData Cate-gory    C-F-I O1.C5.41.0008                                                                                                                                                              C05.041.015 1-53B-07-23                  53B  1-53B-07(1)            NDE-35    PT          SS                      0.134/6.000 Branch                    Class 2 0-ISIN4-102A-1.2 Pipe to Pipe O1.C5.41.0010                                                                                                                                                              C05.041.030 1-51B-1-12AA                  51B  1-51B-1                NDE-35    PT          SS                      0.154 / 2.000              Branch Socket Weld.
Branch                    Class 2  O-ISIN4-101A-1.2 Pipe to Half Coupling Categor      C-F-2 O1.C5.51.0002                                                                                                                                                              C05.051.002, C05.051.002A 1MS-073-13B                  01A  1MS-073                NDE-25    MT          CS                    0.875 /26.000              This weld was previously listed as 1-01A-02-13B Circumferential          Class 2  0-ISIN4-122A-1.1    --                                                                            before the Iso was redrawn.
Procedure NDE-600 uses the component for calibration. Procedure PDI-UT-1 may be used in lieu of NDE-600. If PDI-UT-1 is used, then the calibration block listed shall be used.
Elbow to Pipe O1.C5.51.0002                                                                                                                                                              C05.051.002, C05.051.002A 1MS-073-13B                  01A  lMS-073                NDE-600    UT          CS                    0.875 /26.000  Component    This weld was previously listed as 1-01A-02-13B 0-ISIN4-122A-1.1                                                                    PDI-UT-1-0  before the Iso was redrawn.
Circumferential          Class 2                                                                                                    Procedure NDE-600 uses the component for calibration. Procedure PDI-UT-1 may be used in lieu of NDE-600. If PDI-UT-1 is used, then the calibration block listed shall be used.
Elbow to Pipe O1.C5.51.0004                                                                                                                                                              C05.051.004, C05.051.004A 1-MS1B-B                      01A  1MS-068                NDE-25    MT          CS                    0.875 /26.000              Grinnell subassembly MS-lB.
Circumferential          Class 2                                                                                                    Procedure NDE-600 uses the component for calibration. Procedure PDI-UT-1 may be used in lieu of NDE-600. If PDI-UT-1 is used, then the calibration block listed shall be used.
Elbow to Pipe O1.C5.51.0004                                                                                                                                                              C05.051.004, C05.051.004A 1-MS1B-B                      01A  1MS-068                NDE-600    UT          CS                      0.875 / 26.000 Component    Grinnell subassembly MS-lB.
PDI-UT-1-0  Procedure NDE-600 uses the component for Circumferential          Class 2                                                                                                    calibration. Procedure PDI-UT-1 may be used in Printed 07/17/08 Ick8302 v. 01/19/08                                                        SDQA Cat "C"                              Oconee 1 7/17/2008 5:22:22 PM        Page 34 of 50
 
This report includes all changes tagh          addendum ONS1-087 Oconee 1, 4th Interval,    aou*ge 3 (EOC-24)
Summary Num                                                      Insp Component ID / Type          System  ISO/DWG Numbers    Procedure Req          Mat              Sched ThiclWDia      Cal Blocks Comments /Historical Data Categor      C-F-2 lieu of NDE-600. If PDI-UT-1 is used, then the calibration block listed shall be used.
Elbow to Pipe O1.C5.51.0014                                                                                                                                                            C05.051.014, C05.051.014A 1MS-068-35V                  01A  1MS-068                NDE-25    MT          CS                    0.969 /24.000              Procedure NDE-600 uses the component for Circumferential          Class 2  0-ISIN4-122A-1.1                                                                                calibration. Procedure PDI-UT-1 may be used in lieu of NDE-600. If PDI-UT-1 is used, then the calibration block listed shall be used.
Terminal End Reducer to Nozzle SG 1 B O1 .C5.51.0014                                                                                                                                                          C05.051.014, C05.051.014A 1MS-068-35V                  01A  1MS-068              NDE-600    UT          CS                    0.969 / 24.000 Component  Procedure NDE-600 uses the component for 0-ISIN4-122A-1.1                                                                    PDI-UT-1-0  calibration. Procedure PDI-UT-1 may be used in Circumferential          Class 2                                                                                                  lieu of NDE-600. If PDI-UT-1 is used, then the calibration block listed shall be used.
Terminal End Reducer to Nozzle SG 1 B O1.C5.51.0015                                                                                                                                                            C05.051.015, C05.051.015A 1-MS21A-ID                    01A  1MS-066                NDE-25    MT          CS                    0.969/24.000              Grinnell subassembly MS-21A.
Circumferential          Class 2                                                                                                  Procedure NDE-600 uses the component for calibration. Procedure PDI-UT-1 may be used in lieu of NDE-600. If PDI-UT-1 is used, then the calibration block listed shall be used.
Elbow Y to Pipe O1.C5.51.0015                                                                                                                                                            C05.051.015, C05.051.015A 1-MS21A-D                    01A  1MS-066              PDI-UT-1    UT          CS                    0.969/24.000  Component  Grinnell subassembly MS-21A.
PDI-UT-1-0  Procedure NDE-600 uses the component for Circumferential          Class 2                                                                                                  calibration. Procedure PDI-UT-1 may be used in lieu of NDE-600. If PDI-UT-1 is used, then the calibration block listed shall be used.
Elbow Y to Pipe O1.C5.51.0026                                                                                                                                                            C05.051.026, C05.051.026A 1-FWD64-E                      03  1-03-3(1)              NDE-25    MT          CS                    1.219 / 24.000            Grinnell subassembly FWD-64.
Circumferential            Class 2                                                                                                  Procedure NDE-600 uses the component for calibration. Procedure PDI-UT-1 may be used in lieu of NDE-600. If PDI-UT-1 is used, then the calibration block listed shall be used.
Elbow to Reducer Printed 07/17108 Ick8302 v. 01/19/08                                                          SDQA Cat "C"                          Oconee 1 7/17/2008 5:22:22 PM        Page 35 of 50
 
O                                    This report includes all changes
* gh addendum ONS1-087 Oconee 1, 4th Interval, outage 3 (EOC-24)
Summary Num                                                    Insp Component ID / Type          System  ISO/DWG Numbe.rs    Procedure Req          Mat              Sched ThicklDia      Cal Blocks Comments / HistoricalData Category      C-F-2 O1.C5.51.0026                                                                                                                                                            C05.051.026, C05.051.026A 1-FWD64-E                      03  1-03-3(1)            NDE-600    "UT          CS                    1.219 / 24.000 Component  Grinnell subassembly FWD-64.
PDI-UT-1-0  Procedure NDE-600 uses the component for Circumferential            Class 2                                                                                                  calibration. Procedure PDI-UT-1 may be used in lieu of NDE-600. If PDI-UT-1 is used, then the calibration block listed shall be used.
Elbow to Reducer O1.C5.51.0031                                                                                                                                                            C05.051.031, C05.051.031A 1 CC-136-81B                  55  1CC-136                NDE-25    MT          CS                    0.500 /8.000              This weld was listed previously as 1-55-3-81B Circumferential            Class 2 0-ISIN4-144A-1.2                                                                                until iso 1-55-3 was redrawn.
Procedure NDE-600 uses the component for calibration. Procedure PDI-UT-1 may be used in lieu of NDE-600. If PDI-UT-1 is used, then the calibration block listed shall be used.
Pipe to Elbow O1.C5.51.0031                                                                                                                                                            C05.051.031, C05.051.031A 1CC-136-81B                    55  1CC-136              NDE-600    UT          CS                      0.500 /8.000  Component  This weld was listed previously as 1-55-3-81B 0-ISIN4-144A-1.2                                                                    PDI-UT-1-0  until iso 1-55-3 was redrawn.
Circumferential          Class 2                                                                                                  Procedure NDE-600 uses the component for calibration. Procedure PDI-UT-1 may be used in lieu of NDE-600. If PDI-UT-1 is used, then the calibration block listed shall be used.
Pipe to Elbow O1.C5.51.0041                                                                                                                                                            C05.051.041, C05.051.041A 1LPSW-345-19                  14B  1LPSW-345              NDE-25    MT          CS                    0.500 / 8.000              This weld was listed previously as 1-LPSW-345-Circumferential          Class 2  0-ISIN4-1248-1.2                                                                                19 until iso 1-LPSW-345 was redrawn. This weld was listed previously as 1-LPS-345-19 until iso 1-LPS-345 was deleted.
Procedure NDE-600 uses the component for calibration. Procedure PDI-UT-1 may be used in lieu of NDE-600. If PDI-UT-1 is used, then the calibration block listed shall be used.
Elbow to Pipe 01 .C5.51.0041                                                                                                                                                            C05.051.041, C05.051.041A 1LPSW-345-19                  14B  1LPSW-345            PDI-UT-1    UT          CS                      0.500 /8.000  Component  This weld was listed previously as 1-LPSW-345-0-ISIN4-124B-1.2                                                                    PDI-UT-1-0  19 until iso 1-LPSW-345was redrawn. This Circumferential          Class 2                                                                                                  weld was listed previously as 1-LPS-345-19 until iso 1-LPS-345 was deleted.
Procedure NDE-600 uses the component for calibration. Procedure PDI-UT-1 may be used in lieu of NDE-600. If PDI-UT-1 is used, then the Printed 07/17/08 Ick8302 v. 01/19/08                                                        SDQA Cat "C"                            Oconee 1 7/17/2008 5:22:22 PM        Page 36 of 50
 
This report includes all change          ugh addendum ONSI-087 Oconee 1, 4th Interval, outage 3 (EOC-24)
Summary Num                                                    Insp Component ID / Type          System  ISO/DWG Numbers    Procedure Req          Mat              Sched Thick/Dia      Cal Blocks Comments / HistoricalData Cateqor      C-F-2 calibration block listed shall be used.
Elbow to Pipe O1 .C5.51.0047                                                                                                                                                            C05.051.047, C05.051.047A 1 LPS-911-37                  14B  lLPS-911              NDE-25    MT          CS                      0.500 / 8.000            Procedure NDE-600 uses the component for Circumferential          Class 2  0-ISIN4-124B-1.2                                                                                calibration. Procedure PDI-UT-1 may be used in lieu of NDE-600. If PDI-UT-1 is used, then the calibration block listed shall be used.
This weld was listed previously as 1-LPSW-346-37 on weld iso 1-LPSW-346 until it was transferred to iso 1LPS-911 Pipe to Elbow O1.C5.51.0047                                                                                                                                                            C05.051.047, C05.051.047A 1 LPS-911-37                  14B  1LPS-911              PDI-UT-1    UT          CS                      0.500/8.000  Component  Procedure NDE-600 uses the component for 0-ISIN4-124B-1.2                                                                    PDI-UT-1-0  calibration. Procedure PDI-UT-1 may be used in Circumferential          Class 2                                                                                                  lieu of NDE-600. If PDI-UT-1 is used, then the calibration block listed shall be used.
This weld was listed previously as 1-LPSW-346-37 on weld iso 1-LPSW-346 until it was transferred to iso 1 LPS-91 1 Pipe to Elbow O1.C5.51.0061                                                                                                                                                            C05.051.061, C05.051.061A 1-14-232-1-11                14B  1-14-232-1            NDE-25 "MT              CS                      0.432 /6.000              Procedure NDE-600 uses the component for Circumferential          Class 2  0-ISIN4-121D-1.1                                                                                calibration. Procedure PDI-UT-1 may be used in lieu of NDE-600. If PDI-UT-1 is used, then the calibration block listed shall be used.
Elbow to Tee O1 .C5.51.0061                                                                                                                                                            C05.051.061, C05.051.061A 1-14-232-1-11          . 14B  1-14-232-1            PDI-UT-1    UT          CS                      0.432 /6.000  Component  Procedure NDE-600 uses the component for 0-ISIN4-121D-1.1                                                                    PDI-UT-1-0  calibration. Procedure PDI-UT-1 may be used in Circumferential          Class 2                                                                                                  lieu of NDE-600. If PDI-UT-1 is used, then the calibration block listed shall be used.
Elbow to Tee O1.C5.81.0003                                                                                                                                                              C05.081.003 1-MS23B-C                    01A  1MS-063                NDE-25    MT          CS                      0.500 /8.000              Grinnell subassembly MS-23B.
Branch                    Class 2 Pipe to Pipe Printed 07/17/08 Ick8302 v. 01/19/08                                                          SDQA Cat "C"                            Oconee 1 7/17/2008 5:22:22 PM        Page 37 of 50
 
This report includes all changes
* gh addendum ONS1-087 S
Oconee 1, 4th Interval, outage 3 (EOC-24)
Summary Num                                        -            Insp Component ID / Type          System  ISO/DWG NumberIs    Procedure Req          Mat              Sched Thick/Dia    CCal Blocks Comments / HistoricalData Category      D-A O1.D1.10.0017                                                                                                                                                          D01.010.010 0-19A-447F-H7101                19 O-SSF-41903-02        NDE-65    VT-1          CS                  0.250 /42.000              Standby Shutdown Facility. Diesel Generator Rigid Support            Class 3  0-ISIN4-137D-1.3                                                                              Intake Silencer Welded Attachment.
OM-351-121 O1.D1.10.0018                                                                                                                                                          D01.010.011 0-19A-447F-H7102                19 O-SSF-41903-02        NDE-65    VT-1          CS                  0.250 /42.000              Standby Shutdown Facility. Diesel Generator Rigid Support            Class 3  O-ISIN4-137D-1.3                                                                              Intake Silencer Welded Attachment.
OM-351-121 O1.D1.10.0019                                                                                                                                                          D01.010.012 0-19A-447F-H7119                19 0-SSF-41903-01        NDE-65    VT-1          NA                  0.625 /48.000              Standby Shutdown Facility. Diesel Generator Rigid Support            Class 3  O-320-J6                                                                                      Exhaust Silencer Welded Attachment. This OM-351-75                                                                                      support attachment is listed on O-ISIN4-137D-1.3.
O1.D1.10.0020                                                                                                                                                          D01.010.013 0-19A-447F-H7120                19 O-SSF-41903-01        NDE-65    VT-1          NA                  0.625 /48.000              Standby Shutdown Facility. Diesel Generator Rigid Support            Class 3  0-320-J6                                                                                      Exhaust Silencer Welded Attachment. This OM-351-75                                                                                      support attachment is listed on O-ISIN4-137D-1.3.
O1.D1.20.0014                                                                                                                                                          001.020.030 D
1-03A-1-0-400B-H59            03A  1-03A-09/sht.4        NDE-65    VT-1          NA                  0.125 / 6.000              Calculation No. OSC-342, page 104. Inspect Rigid Support            Class 3  0-ISIN4-121D-1.1                                                                              with F01.030.048.
O1.D1.20.0021                                                                                                                                                          D01.020.051 1-13-0-400B-JEJ-1901          13  1-13-09/sht.1          NDE-65    VT-1          NA                  0.250/30.000              Calculation No. OSC-1636. Inspect with Rigid Restraint          Class 3  0-ISIN4-133A-1.1                                                                              F01o.031.056.
O1.D1.20.0023                                                                                                                                                          D01.020.062 1-14B-1-0-400B-H31            14B  1-14A-01/sht.1        NDE-65    VT-1          NA                  0.187 / 36.000              Calculation No. OSC-395, page 40. Inspect Spring Hgr                Class 3  0-ISIN4-124A-1.1                                                                              with F01.032.083.
O1.D1.20.0094                                                                                                                                                            D01.020.
1-03A-401B-DE049              03A  1-03A-06/sht.3        NDE-65    VT-1                              0.500 / 6.000              Calculaton No. OSC-340, page 90 Rigid Support            Class 3  0-ISIN4-121D-1.1 O1.D1.20.0248                                                                                                                                                          D01.020.070 0-19A-447F-H7123                19 O-SSF-41903-01        NDE-65    VT-1          NA                  0.500 /22.000              Standby Shutdown Facility. Diesel Generator Spring Hgr                Class 3  0-ISIN4-137D-1.3                                                                              Exhaust Piping Welded Attachment.
Printed 07/17/08 Ick8302 v. 01/19/08                                                        SDQA Cat "C"                          Oconee 1 7/17/2008 5:22:22 PM      Page 38 of 50
 
This report includes all changes *gh          addendum ONS1-087 Oconee 1, 4th Interval, outage 3 (EOC-24)
Summary Num                                                      Insp Component ID / Type          System  ISO/DWG Numbers    Procedure Req          Mat              Sched Thick/Dia        Cal Blocks Comments / HistoricalData Cate-go      D-A O1 .D1.20.0249                                                                                                                                                          D01.020.071 0-19A-447F-H7094                19 O-SSF-41903-02        NDE-65    VT-i        CS                      0.280 / 24.000            Standby Shutdown Facility. Diesel Generator Rigid Support              Class 3 0-ISIN4-137D-1.3                                                                                Intake Piping Welded Attachment.
O1.D1.20.0250                                                                                                                                                          " D01.020.072 0-19A-447F-H7103                19 o-SSF-41903-02        NDE-65    VT-1        CS                    0.280 / 24.000              Standby Shutdown Facility. Diesel Generator Rigid Support              Class 3 0-ISIN4-137D-1.3                                                                                Intake Piping Welded Attachment.
Category      ELC O1 .H2.1.0001                                                                                                                                                            H02.001.001 1-PHA-13                      50  ISI-OCN1-005          NDE-35      PT    CS-Inconel                  2.875 /9.000              RTE Mounting Boss. This weld covers the X Circumferential          Class 1  OM-201-2296                                                                                      axis. The diameter of the hole that penetrates the nozzle into the Hot Leg = .613". Reference Section 7 of the ISI Plan, General Requirements.
Dissimilar Pipe to Pipe O1.H2.1.0002                                                                                                                                                            H02.001.002 1-PHA-14                      50 ISI-OCN1-005            NDE-35      PT    CS-Inconel                  2.875 /9.000              RTE Mounting Boss. This weld covers the Y-Z Circumferential          Class 1 OM-201-2296                                                                                      Quadrant. The diameter of the hole that penetrates the nozzle into the Hot Leg = .613".
Reference Section 7 of the ISI Plan, General Requirements.
Dissimilar Pipe to Pipe 01 .H2.1.0003                                                                                                                                                            H02.001.003 1-PHA-15                      50  ISI-OCN1-005          NDE-35      PT    CS-Inconel                  2.875 /9.000              RTE Mounting Boss. This weld covers the Z-W Circumferential          Class 1  OM-201-2296                                                                                      Quadrant. The diameter of hole that penetrates the nozzle into the Hot Leg = .613". Reference Section 7 of the ISI Plan, General Requirements.
Dissimilar Pipe to Pipe 01.H2.1.0010                                                                                                                                                            H02.001.010 1-PIB2-12                      50 ISI-OCN1-010            NDE-35      PT    CS-Inconel                  2.250 / 8.750              RTE Mounting Pipe. This weld covers the Z-W Branch                    Class 1 OM-201-1845                                                                                      Quadrant. The diameter of hole that penetrates the nozzle into the RCP 1 B2 Suction Piping =
                                                                                                                                        .613". Reference Section 7 of the ISI Plan, General Requirements.
Dissimilar Salvaged Pipe to Pipe Printed 07/17/08 Ick8302 v. 01/19/08                                                        SDQA Cat "C"                            Oconee 1 7/17/2008 5:22:22 PM      Page 39 of 50
 
0                                      This report includes all change*          ugh addendum ONSI-087 Oconee 1, 4th Interval, outage 3 (EOC-24)
Summary Num                                                    Insp Component ID / Type          System  ISO/DWG Numbers    Procedure Req          Mat              Sched ThicW/Dia    Cal Blocks Comments / HistoricalData Cate-go      ELC 01 .H4.11.0008                                                                                                                                                          H04.001.008, H04.001.008A 1-03-0-551-R7                  03  1-03-01/sht.1          NDE-25    MT          NA                  1.000 /24.000              Calculaton No. OSC-336, page 45a.1 Hyd Snubber              Class 3  0-ISIN4-121B-1.3                                                                                --(H04.001.008A)Perform a Surface exam on the attachment welds.
Note: Magnetic Particle examinations (with the use of procedure NDE-25) may be performed on carbon steel material in lieu of or in conjunction with liquid penetrant examinations.
01..H4.11.0008                                                                                                                                                          H04.001.008, H04.001.008A 1-03-0-551-R7                  03  1-03-01/sht.1          NDE-66    VT-3          NA                  1.000 / 24.000            Calculaton No. OSC-336, page 45a.1 Hyd Snubber              Class 3  0-ISIN4-121B-1.3                                                                                --(H04.001.008A)Perform a Surface exam on the attachment welds.
Note: Magnetic Particle examinations (with the use of procedure NDE-25) may be performed on carbon steel material in lieu of or in conjunction with liquid penetrant examinations.
01.H4.1.0009                                                                                                                                                              H04.001.009 1-03-0-551-R11                03  1-03-01/sht.1          NDE-66    VT-3          NA                  0.000 /24.000              Calculation No. OSC-336, page 45a.1.
Rigid Support            Class 3  0-ISIN4-121B-1.3                                                                              Inspect with item number F01.030.021 01.H4.1.0014                                                                                                                                                              H04.001.014 1-03-0-551-H60                03  1-03-01/sht.1          NDE-66    VT-3          NA                  0.000 /24.000              Calculation No. OS-336, page 45a.1 Rigid Support            Class 3  0-ISIN4-121B-1.3 01 .H4.11.0015                                                                                                                                                          H04.001.015, H04.001.015A 1-03-4011B-H4171              03  1-03-01/sht.1          NDE-25    MT          NA                  0.375 /24.000              Calculation No. OSC-336 --
Mech Snubber              Class 3  0-ISIN4-121B-1.3                                                                              (H04.001.015A)Perform a Surface exam on the attachment welds.
Note: Magnetic Particle examinations (with the use of procedure NDE-25) may be performed on carbon steel material in lieu of or in conjunction with liquid penetrant examinations.
01..H4.1.0015                                                                                                                                                          H04.001.015, H04.001.015A 1-03-4011B-H4171              03  1-03-01/sht.1          NDE-66    V'-3          NA                  0.375 / 24.000            Calculation No. OSC-336 --
Mech Snubber              Class 3  0-ISIN4-121B-1.3                                                                              (H04.001.015A)Perform a Surface exam on the attachment welds.
Note: Magnetic Particle examinations (with the use of procedure NDE-25) may be performed on carbon steel material in lieu of or in conjunction with liquid penetrant examinations.
Printed 07/17/08 Ick8302 v. 01/19/08                                                          SDQA Cat "C"                          Oconee 1 7/17/2008 5:22:22 PM        Page 40 of 50
 
0                                    This report includes all changes t        gh addendum ONSI-087 Oconee 1, 4th Interval, outage 3 (EOC-24) 0 Summary Num                                                      Insp Component ID / Type          System  ISOIDWG Numberrs    Procedure Req          Mat            Sched Thick/Dia    Cal Blocks Comments / HistoricalData Category      ELC 01 .H4.1.0016                                                                                                                                                          H04.001.016, H04.001.016A 1-03-0-551-R12                03  1-03-01/sht.1          NDE-25    MT          NA                  1.000 /24.000              Calculation No. OS-336, page 45a.1 Hyd Snubber              Class 3  0-ISIN4-121B-1.3                                                                              --(H04.001.016A)Perform a Surface exam on the attachment welds.
Note: Magnetic Particle examinations (with the use of procedure NDE-25) may be performed on carbon steel material in lieu of or in conjunction with liquid penetrant examinations.
O1 .H4.1.0016                                                                                                                                                          H04.001.016, H04.001.016A 1-03-0-551-R12                03  1-03-01/sht.1          NDE-66    VT-3        NA                  1.000 /24.000              Calculation No. OS-336, page 45a.1 Hyd Snubber              Class 3  O-ISIN4-121B-1.3                                                                              --(H04.001.016A)Perform a Surface exam on the attachment welds.
Note: Magnetic Particle examinations (with the use of procedure NDE-25) may be performed on carbon steel material in lieu of or in conjunction with liquid penetrant examinations.
O1 .H4.1.0017                                                                                                                                                            H04.001.017 1-03-0-551-R13                03  1-03-01/sht.1          NDE-66    VT-3      - NA                  0.000 /24.000              Calculation No. OS-336, page 45a.1 Mech Snubber              Class 3  0-ISIN4-121B-1.3 O1 .H4.1.0018                                                                                                                                                          H04.001.018, H04.001.018A 1-03-0-551-H59                03  1-03-01/sht.1          NDE-25    MT          NA                  2.500 / 24.000            Calculation No. OSC-336, page 45a.1 Spring Hgr                Class 3  0-ISIN4-121B-1.3                                                                              --(H04.001.018A)Perform a Surface exam on the attachment welds.
Note: Magnetic Particle examinations (with the use of procedure NDE-25) may be performed on carbon steel material in lieu of or in conjunction with liquid penetrant examinations.
O1 .H4.1.0018                                                                                                                                                          H04.001.018, H04.001.018A 1-03-0-551-H59                03  1-03-01/sht.1          NDE-66    VT-3        NA                  2.500 /24.000              Calculation No. OSC-336, page 45a.1 Spring Hgr                Class 3  0-ISIN4-121B-1.3                                                                              --(H04.001.018A)Perform a Surface exam on the attachment welds.
Note: Magnetic Particle examinations (with the use of procedure NDE-25) may be performed on carbon steel material in lieu of or in conjunction with liquid penetrant examinations.
Printed 07/17/08 Ick8302 v. 01/19/08                                                        SDQA Cat "C"                          Oconee 1 7/17/2008 5:22:22 PM        Page 41 of 50
 
This report includes all changes          h addendum ONSI-087 Oconee 1, 4th Interval,outage3 (EOC-24)                                                                0 Summary Num                                                          Insp Component ID / Type            System    ISOIDWG Numbers    Procedure Req            Mat            Sched Thick/Dia    Cal Blocks Comments / HistoricalData Categor      ELC 01.H4.1.0019                                                                                                                                                              H04.001.019, H04.001.019A 1-03-0-551-H58                    03  1-03-01/sht.1          NDE-25      MT          NA                0.375 / 24.000              Calculation No. OSC-336 Page 45a.1 Spring Hgr                  Class 3  0-ISIN4-121B-1.3                                                                              --(H04.001.019A)Perform a Surface exam on the attachment welds.
Note: Magnetic Particle examinations (with the use of procedure NDE-25) may be performed on carbon steel material in lieu of or in conjunction with liquid penetrant examinations.
O1.H4.1.0019                                                                                                                                                              H04.001.019, H04.001.019A 1-03-0-551-H58                    03 . 1-03-01/sht.1          NDE-66    VT-3        NA                0.375 / 24.000              Calculation No. OSC-336 Page 45a.1 Spring Hgr                  Class 3 0-ISIN4-121B-1.3                                                                                --(H04.001.019A)Perform a Surface exam on the attachment welds.
Note: Magnetic Particle examinations (with the use of procedure NDE-25) may be performed on carbon steel material in lieu of or in conjunction with liquid penetrant examinations.
Cate-go        F-. k O1 .Fl.10.0001                                                                                                                                                              F01.010.001 1-51A-0-479A-H11B                51A  1-51-26/sht.1          NDE-66    VT-3        NA                  0.000 /2.500              Calculation No. OSC-1304-06, page 6(1)31 Rigid Support                Class 1  0-ISIN4-101A-1.4                                                                              High Pressure Injection.
O1 .Fl.10.0004                                                                                                                                                              F01.010.004 51A-0-478A-H3C                51A  1-55-03/sht.4 .        NDE-66    VT-3        NA.                0.750/2.500                Calculation No. OSC-1660-11, page 68 High Rigid Support                Class 1  0-ISIN4-101A-1.1                                                                              Pressure Injection. Inspect with B10.020.006.
Ot.F1.10.0007                                                                                                                                                                F01.010.007 1-51A-0-A79A-H9A                51A  1-51-15/sht.1          NDE-66    VT-3        NA                  0.375/2.500                Calculation No. OSC-1304-06, page 61 Rigid Support                Class 1  0-ISIN4-101A-1.4                                                                              High Pressure Injection.
O1 .Fl.11.0001                                                                                                                                                              F01.011.001 1-51A-0-479A-H1OB              51A    1-51-26/sht.1          NDE-66    VT-3        NA                  0.000 / 2.500              Calculation No. OSC-1304-06, page 6(1)32 Rigid Restraint              Class 1  0-ISIN4-101A-1.4                                                                              High Pressure Injection.
01.F1.11.0002                                                                                                                                                                F01.011.002 1-51A-0-478A-H2C                51A    1-55-03/sht.4          NDE-66    VT-3        NA                  0.154 / 2.500              Calculation No. OSC-1660-1 1, page 68 Rigid Restraint              Class 1  0-ISIN4-101A-1.1                                                                              High Pressure Injection.
                                                                                                          "C"                        Oconee 1 7/17/2008 5:22:22 PM          Page 42 of 50 07/17/08 Icki v:01/19/08 Printed 3302 v.,01/19/08 Printed 07/17/08 Ick 8302                                                                      SDQA Cat SDQA  Cat "C"                        Oconee 1 7/17/2008 5:22:22 PM          Page 42 of 50
 
S                                      This report includes all changes*        ugh addendum ONSI-087 Oconee 1, 4th Interval, outage 3 (EOC-24)
Summary Num                                                    Insp Component ID / Type          System  ISO/DWG Numberrs  Procedure Req          Mat              Sched Thick/Dia    'al Blocks Comments / HistoricalData Cate-go      F-A 01.F1.12.0006                                                                                                                                                      F01.012.006 1-51A-0-478A-H1C              51A 1-55-03/sht.4          NDE-66    VT-3        NA                    0.750 / 2.500            Calculation No. OSC-1660-11, page 68 Spring Hgr                Class 1 0-ISIN4-101A-1.1                                                                              High Pressure Injection.
01.F1.12.0009                                                                                                                                                      F01.012.009 1-53A-0-478A-H5B              53A 1-53-08                NDE-66    VT-3        NA                  0.000 /10.000              Calculation No. OSC-1300.
Spring Hgr                Class 1 0-ISIN4-102A-1.3 01 1F1.20.0002                                                                                                                                                      F01.020.002 1-01A-0-550rH2                01A  1-01-01/sht.1          NDE-66    VT-3        NA                  0.000/34.000              Calculation No. OSC-320, page 131.1.
Rigid Support            Class 2  0-ISIN4-122A-1.1 01 .F1.20.0007                                                                                                                                                      F01.020.021 1-14-478E-H6014                14  1-03A-14/sht.3        NDE-66    VT-3        NA                  0.000 / 6.000              Calculation No. OSC-1224-16, page 44.
Rigid Support            Class 2  0-ISIN4-121D-1.1 O1 .Fl.20.0013                                                                                                                                                      F01.020.042 1-51-0-435C-SR4                51  1-51-02/sht.2          NDE-66    VT-3        NA                  0.750/6.000                Calculation No. OSC-1535, page 136.
Rigid Support            Class 2  0-ISIN4-101A-1.3 0-1AB-15102-02 O1.F1.20.0014                                                                                                                                                      F01.020.043 1-51-0-435C-SR5                51  1-51-02/sht.2          NDE-66    VT-3        NA                  0.750/6.000                Calculation No. OSC-1535, page 136.
Rigid Support            Class 2  0-ISIN4-101A-1.3 0-1AB-1i5102-02 01 .F1.20.0016                                                                                                                                                      F01.020.045 1-51-0-436D-SR10              51  1-51-01/sht.1          NDE-66    VT-3        NA                  0.750 / 4.000              Calculation No. OSC-400, page 50.
Rigid Support            Class 2  0-ISIN4-101A-1.1 0-1AB-15101-01 01 .F1.20.0017                                                                                                                                                      F01.020.046 1-51-0-436H-SR19              51  1-51-01/sht.1          NDE-66    VT-3        NA                  0.750 / 4.000              Calculation No. OSC-400, page 50.
Rigid Support            Class 2  0-ISIN4-101A-1.1 0-1AB-1i5101-01 01 .F1.20.0020                                                                                                                                                      F01.020.049 1-51-0-436D-SR7                51  1-51-06/sht.2          NDE-66    VT-3        NA                  0.750 / 4.000              Calculation No. OSC-1538, page 94.
Rigid Support            Class 2  0-ISIN4-101A-1.1 O-lAB-15106-02 Printed 07/17/08 Ick8302 v. 01/19/08                                                        SDQA Cat "C"                          Oconee 1 7/17/2008 5:22:22 PM    Page 43 of 50
 
S                                      This report includes all change*ugh addendum ONS1-087 Oconee 1, 4th Interval, outage 3 (EOC-24) er Summary Num                                                      Insp Component ID / Type          System  ISO/DWG Numbers    Procedure Req          Mat              Sched ThicWlDia    Cal Blocks Comments / HistoricalData Categor      F-A O1.Fl.20.0028                                                                                                                                                      F01.020.067 1-51A-1-0-444-H1              51A  1-51-04/sht.1          NDE-66    VT-3        NA                  0.500 /4.000              Calculation No. OSC-1639, page 30.5.
Rigid Support            Class 2  0-ISIN4-101A-1.4 O-lAB-15104-01 O1.Fl.20.0043                                                                                                                                                      F01.020.099 1-53B-5-0-444-H6              53B  1-53-02/sht.2          NDE-66    VT-3        NA                  1.000 /10.000            Calculation No. OSC-408. Inspect with Rigid Support            Class 2  0-ISIN4-102A-1.2                                                                              C03.020.096.
O-lAB-15302-02 O1.Fl.20.0045                                                                                                                                                      F01.020.101 1-53B-5-0-439-R14            53B  1-53-02/sht.3          NDE-66    VT-3        NA                  0.000 /10.000            Calculation No. OSC-408.
Rigid Support            Class 2  0-ISIN4-102A-1.2 O-lAB-15302-03 O1.Fl.20.0047                                                                                                                                                      F01.020.103 1-53B-6-0-439C-H13            53B  1-53-02/sht.3          NDE-66    VT-3        NA                  0.322 / 8.000            Calculation No. OSC-408.
Rigid Support            Class 2  0-ISIN4-102A-1.1 0-1AB-15302-03 O1 .Fl.20.0048                                                                                                                                                      F01.020.111 1-54A-435B-DE-05              54A  1-54-02/sht.1          NDE-66    VT-3        NA                  0.125 /8.000              Calculation No. OSC-415, page 50.
Rigid Support            Class 2  0-ISIN4-103A-1.1 O1 .Fl.20.0055                                                                                                                                                      F01.020.131 1-56-4-0-437B-H1              56  4-56-02/sht.3          NDE-66    VT-3        NA                  0.125 / 8.000            Calculation No. OSC-421, page 95.1. Inspect Rigid Support            Class 2  0-ISIN4-102A-1.1                                                                              with C03.020.121.
O1 .F1.21.0002                                                                                                                                                      F01.021.021 1-03A-0-439A-DE068            03A  1-03A-05/sht.3        NDE-66    VT-3        NA                  0.000 / 6.000            Calculation No. OSC-339, page 81.
Rigid Restraint          Class 2  0-ISIN4-121D-1.2 O1 .Fl.21.0003                                                                                                                                                      F01.02,1.031 1-14-0-480A-H21C              14  1-14-16/sht.1          NDE-66    VT-3        NA                  0.000 / 8.000            Calculation No. OSC-1306-06, page 6(2)-43.
Rigid Restraint          Class 2  0-ISIN4-124B-1.2 O1 .Fl.21.0005                                                                                                                                                      F01.021.033 1-14-0-479A-H20A              14  1-14-13                NDE-66    VT-3        NA                  1.000 /8.000              Calculation No. OSC-1306-06, page 6(4)-44.
Rigid Restraint          Class 2  0-ISIN4-124B-1.2 Printed 07/17/08 Ick8302 v. 01/19/08                                                        SDQA Cat "C"                          Oconee 1 7/17/2008 5:22:22 PM    Page 44 of 50
 
This report includes all changes *q        gh addendum ONSI-087 Oconee 1, 4th Interval, outage 3 (EOC-24)
Summary Num                                                    Insp Component ID / Type        System  ISO/DWG Numbe rs    Procedure Req          Mat              Sched ThictWDia    ,al Blocks Comments / HistoricalData Cate-go      F-A O1 .Fl.21.0014                                                                                                                                                        F01.021.054 1-51-0-436H-SR17              51  1-51-01/sht.2          NDE-66    VT-3        NA                  0.750 / 4.000              Calculation No. OSC-400, page 51. Inspect Rigid Restraint          Class 2 0-ISIN4-101A-1.2                                                                              with C03.020.052.
O-1AB-15101-02 O1 .F1.21.0017                                                                                                                                                        F01.021.062 1-51A-0-444-H 114            51A  1-51-13/sht.2          NDE-66    VT-3        NA                  0.000/4.000                Calculation No. OSC-1410, page 104. High Rigid Restraint          Class 2 0-ISIN4-101A-1.3                                                                              Pressure Injection Cross Connect Header.
O-1AB-15113-02 O1 .Fl.21.0028                                                                                                                                                        F01.021.094 1-53B-2-0-436E-H7            53B  1-51-02/sht.2          NDE-66    VT-3        NA                  0.000 / 6.000              Calculation No. OSC-1535, page 136.
Rigid Restraint          Class 2 0-ISIN4-101A-1.3 O-1AB115102-02 O1 .Fl.21.0032                                                                                                                                                      F01.021.102 1-54A-3-0-439A-R1 1          54A  1-54-03/sht.1          NDE-66    VT-3        NA                  1.000 /8.000              Calculation No. OSC-416, page 58.1. Inspect Rigid Restraint          Class 2 0-ISIN4-103A-1.1                                                                              with C03.020.104.
O1.Fl.21.0077                                                                                                                                                            F01.021.
1-53B-0-439,,-DE054          53B  1-53-05/sht.1          NDE-66    VT-3                              0.000 / 10.000            Calculation No. OSC-410, page 54 Rigid Restraint          Class 2 0-ISIN4-102A-1.2 O-lAB-15305-01 01.F1.21.0192                                                                                                                                                        F01.021.022 1-03A-4-PEN # 50            03A  1-03A-4 (1)            NDE-66    VT-3        CS                  0.750 /8.000              0-1RB-103A14-01, Problem No. 1-03A-14, Rigid Restraint          Class 2 0-62A                                                                                          Drawing 0-ISIN4-121D-1.1. Type II Penetration 0-62C                                                                                          located on Reactor Bid side of Penetration # 50.
O1.F1.21.0195                                                                                                                                                        F01.021.122 1SF-107-PEN # 56              56  1SF-107                NDE-66    VT-3        CS                  0.750 /8.000              O-1RB-15307-04, Problem No. 1-53-07.
Rigid Restraint          Class 2 0-62A                                                                                          Drawing 0-ISIN4-104A-1.1. Type I Penetration 0-62C                                                                                          located on Reactor Bid side of Penetration # 56.
O1.F1.22.0005                                                                                                                                                        F01.022.005 1-01A-1-1-0-401A-H7          01A  1-01-02/sht.3          NDE-66    VT-3        NA                  0.000 / 12.000            Calculation No. OSC-321.
Spring Hgr                Class 2 0-ISIN4-122A-1.2 O1 .Fl:22.0006                                                                                                                                                      F01.022.006 1-01A-0-550-R7              01A  1-01-01/sht.1          NDE-66    VT-3          NA                  1.000 / 34.000            Calculation No. OSC-320, page 131.1. Inspect Mech Snubber              Class 2 0-ISIN4-122A-1.1                                                                              with C03.020.002 and F01.050.050.
Printed 07/17/08 1ck8302 v.01/19/08                                                          SDQA Cat "C"                          Oconee 1 7/17/2008 5:22:22 PM      Page 45 of 50
 
0                                      This report includes all change*        ugh addendum ONS1-087 Oconee 1, 4th Interval, outage 3 (EOC-24)
Summary Num                                                    Insp Component ID / Type          System  ISOIDWG Numberrs    Procedure Req          Mat              Sched ThicklDia    Cal Blocks Comments / HistoricalData Categqor      F-A O1 .Fl.22.0019                                                                                                                                                      F01.022.091 1-53A-0-479A-H5B              53A  1-53-07/sht.2          NDE-66    VT-3        NA                  0.000 / 12.000            Calculation No. OSC-1301-06, page 92. Inspect Hyd Snubber              Class 2  0-ISIN4-102A-1.1                                                                              with F01.050.054.
O1.Fl.22.0028                                                                                                                                                      F01.022.112 1-54A-3-0-439A-H25A          54A  1-54-01/sht.1          NDE-66    VT-3        NA                  0.000 / 8.000              Calculation No. OSC-416, page 58.1.
Spring Hgr                Class 2  0-ISIN4-103A-1.1 O1.Fl.30.0003                                                                                                                                                        F01.030.021 1-03-0-551-R 11                03  1-03-01/sht.1          NDE-66    VT-3        NA                  0.000 /24.000              Calculation No. OSC-336, page 45a.1.
Rigid Support            Class 3  0-ISIN4-121B-1.3                                                                              Inspect with item H04.001.009.
011F1.30.0021                                                                                                                                                      F01.030.047 1-03A-1-0-400B-H50            03A  1-03A-09/sht.3        NDE-66    VT-3        NA                  0.200 /6.000              Calculation No. OSC-342, page Rigid Support            Class 3  0-ISIN4-121D-1.1                                                                              103.
O1 .Fl.30.0022                                                                                                                                                      F01.030.048 1-03A-1-0-400B-H59            03A  1-03A-09/sht.4        NDE-66    VT-3        NA                  0.125 / 6.000              Calculation No. OSC-342, page 104.
Rigid Support            Class 3  0-ISIN4-121D-1.1 01 .F1.30.0023                                                                                                                                                      F01.030.049 1-03A-1-0-400A-H34            03A  1-03A-09/sht.5        NDE-66    VT-3        NA                  0.500 / 6.000              Calculation No. OSC-342, page Rigid Support            Class 3  0-ISIN4-121D-1,1                                                                              105.
01 1F1.30.0026                                                                                                                                                      F01.030.052 2-03A-1401B-DE007            03A  2-03A-04/sht.3        NDE-66    VT-3        NA                  0.000 /6.000              Calculation No. OSC-457, page 43. This support Rigid Support            Class 3  0-ISIN4-121D-2.1                                                                              was moved from Unit 2 due to boundary change.
01 5F1.30.0027                                                                                                                                                      F01.030.053 2-03A-1-0-1401B-SR16          03A 2-03A-04/sht.3          NDE-66    VT-3        NA                  0.000/6.000                Calculation No. OSC-457, page 43, This support Rigid Support            Class 3 O-ISIN4-121D-2.1                                                                              was moved from Unit 2 due to boundary change.
O1 .Fl.30.0039                                                                                                                                                      F01.030.091 1-14B-0-436L-ASR14            14B  4-14-03/sht.4          NDE-66    VT-3        NA                  0.000 / 8.000              Calculation No. OSC-394, page 79.
Rigid Support            Class 3  0-ISIN4-121D-1.2 Printed 07/17/08 Ick8302 v. 01/19/08                                                        SDQA Cat "C"                          Oconee 1 7/17/2008 5:22:22 PM    Page 46 of 50
 
This report includes all changeQugh addendum ONSI-087 Oconee 1, 4th Interval, outage 3 (EOC-24)
Summary Num                                                    Insp Component ID / Type        System  ISOIDWG Numberrs  Procedure Req            Mat            Sched Thick/Dia    C;al Blocks Comments / HistoricalData Categor      F-A 011F1.30.0040                                                                                                                                                        F01.030.092 1-14B-439B-DE009              14B  1-14-06/sht.1          NDE-66    VT-3        NA                  0.000 / 10.000              Calculation No. OSC-1541, page 100.
Rigid Support              Class 3 O-ISIN4-124B-1.4 O1.Fl.30.0051                                                                                                                                                        F01.030.103 1-14B-437A-SR60              14B  1-14-06/sht.1          NDE-66    VT-3        NA                  1.000 /20.000                Calculation No. OSC-1541, page 100.
Rigid Support              Class 3 0-ISIN4-124B-1.1 O1.Fl.30.0052                                                                                                                                                        F01.030.104 2-14B-1400A-DE144            14B  1-14-06/sht.3          NDE-66    VT-3        NA                  0.000/ 12.000                Calculation No. OSC-1541, page 102.
Rigid Support            Class 3  0-ISIN4-124B-1.1 O1.Fl.30.0058                                                                                                                                                        F01.030.133 1-56-443-H5106                56  4-56-02/sht.7          NDE-66    VT-3        NA                  0.000 / 8.000                Calculation No. OSC-421, page 99.
  ,Rigid Support              Class 3 0-ISIN4-104A-1.1 O1 .Fl.30.0064                                                                                                                                                        F01.030.152 0-SSW-448K-H7362(A)            SS 4-SSW-01/sht.1          NDE-66    VT-3        NA                  0.000 / 6.000                Calculation No. OSC-6068.
                                  'W Rigid Support            Class 3  0-ISIN4-129A-1.1 0-4RWF-4SSW01-01 01.Fl.30.0222                                                                                                                                                            F01.030.
1-03A-401 B-DE049            03A  1-03A-06/sht.3        NDE-66    VT-3                              0.500 / 6.000                Calculaton No. OSC-340, page 90 Rigid Support            Class 3  0-ISIN4-121D-1.1 O1.F1.30.0584                                                                                                                                                        F01.030.120 0-19A-447F-H7094                19 O-SSF-41903-02        NDE-66    VT-3        CS                  0.280 / 24.000              Standby Shutdown Facility. Diesel Generator Rigid Support            Class 3  0-ISIN4-137D-1.3                                                                                Intake Piping.
O1.Fl.30.0585                                                                                                                                                        F01.030.121 0-19A-447F-H7103                19 O-SSF-41903-02        NDE-66    VT-3        CS                  0.280 / 24.000              Standby Shutdown Facility. Diesel Generator Rigid Support            Class 3  0-ISIN4-137D-1.3                                                                                Intake Piping.
01 1F1.31.0017                                                                                                                                                        F01.031.056 1-13-0-400E-JEJ-1901          13. 1-13-09/sht.1          NDE-66    VT-3        NA                  0.250 / 30.000          -  Calculation No. OSC-1636. Inspect with Rigid Restraint          Class 3  0-ISIN4-133A-1.1                                                                                D01.020.051.
Printed 07/17/08 Ick8302 v. 01/19/08                                                        SDQA Cat "C"                            Oconee 1 7/17/2008 5:22:22 PM    Page 47 of 50
 
0                                    This report includes all changes0 ugh addendum ONS1 -087 Oconee 1, 4th Interval, outage 3 (EOC-24)                                                          0 Summary Num                                                    Insp Component ID / Type          System  ISOIDWG Number*s  Procedure Req          Mat              Sched ThicklDia    Cal Blocks Comments / HistoricalData Catecory      F-A O1.Fl.31.0024                                                                                                                                                      F01.031.075 1-14B-436D-DE063              14B  4-14-03/sht.4          NDE-66    VT-3        NA                  0.237 /8.000              Calculation No. OSC-394, page 79.
Rigid Restraint          Class 3  0-ISIN4-121D-1.2 O1 .Fl.31.0025                                                                                                                                                      F01.031.101 1-56-4373-15110                56  4-56-02/sht.7          NDE-66    VT-3        NA                  0.000 /8.000              Calculation No. OSC-421, page 99.
Rigid Restraint          Class 3  0-ISIN4-104A-1.1 01 .F1.31.0058                                                                                                                                                          F01.031.
1-14B-0-400B-SR34            14B  1-14-06/sht.2          NDE-66    VT-3                              0.875 / 12.000            Calculation No. OSC-1541 Page 101 Rigid Restraint          Class 3  0-ISIN4-124A-1.1 O1.Fl.31.0213                                                                                                                                                      F01.031.090 0-19A-447F-H7118                19 O-SSF-41903-01        NDE-66    VT-3        NA                  0.000 / 22.000            Standby Shutdown Facility. Diesel Generator Rigid Restraint          Class 3  0-ISIN4-137D-1.3                                                                              Exhaust Piping.
O-320-J3 O1 .Fl.32.0001                                                                                                                                                      F01.032.001 1-01A-4-1-0-401A-H2          01A  1-01-06/sht.1          NDE-66    VT-3        NA                  0.000 / 6.000              Calculation No. OSC-325, page 88.
Spring Hgr                Class 3  0-ISIN4-122A-1.4 01.F71.32.0007                                                                                                                                                      F01.032.021 1-03A-1-0-439B-H21            03A  1-03A-05/sht.2        NDE-66    VT-3        NA                  0.000 /6.000              Calculation No. OSC-339, page 80.
Spring Hgr                Class 3  0-ISIN4-121D-1.1 O1 .Fl.32.0017                                                                                                                                                      F01.032.081 1-14B-437A-DE060              14B  1-14-05/sht.1          NDE-66    VT-3        NA                  0.000/16.000              Calculation No. OSC-393, page 78.
Spring Hgr                Class 3  0-ISIN4-124B-1.1 O1.F1.32.0019                                                                                                                                                      F01.032.083 1-14B-1-0-400B-H31            14B  1-14A-01/sht.1        NDE-66    VT-3        NA'                  0.187 / 36.000            Calculation No. OSC-395, page 40. Inspect Spring Hgr                Class 3  0-ISIN4-124A-1.1                                                                              with D01.020.062.
01 5F1.32.0140                                                                                                                                                      F01.032.100 0-19A-447F-H7123              19  O-SSF-41903-01        NDE-66    VT-3        NA                  0.500 I 22.000            Standby Shutdown Facility. Diesel Generator Spring Hgr                Class 3  0-ISIN4-137D-1.3                                                                              Exhaust Piping.
Printed 07/17/08 Ick8302 v. 01/19/08                                                        SDQA Cat "C"                          Oconee 1 7/17/2008 5:22:22 PM      Page 48 of 50
 
This report includes all changes O      ugh addendum ONSI-087 Oconee 1, 4th Interval,outage 3 (EOC-24)
Summary Num                                                      Insp.
Component ID / Type          System  ISO/DWG Numbers    Procedure Req          Mat            Sched Thick/Dia    Cal Blocks Comments / HistoricalData Categor      F-A O1.Fl.40.0010                                                                                                                                                        F01.040.010 1-EFDW-MD-PU-A                03A  OM 206-0036            NDE-66    VT-3        NA                  0.000 /0.000              Emergency Feedwater Motor Driven Pump 1A, Class3  0-ISIN4-121D-1.1                                                                              Pump Support & Pad.
O1 .Fl.40.0011                                                                                                                                                        F01.040.011
                                                                \
1-EFDW-PT                    03A  OM 200B-0006          NDE-66    VT-3        NA                  0.000 /0.000              Emergency Feedwater Pump Turbine. Ref. Fig Class 3  0-ISIN4-122A-1.4                                                                              1 in Manual Om-200B-0006, Items 12 & 18.
O1.Fl.40.0012                                                                                                                                                        F01.040.012 1-EFDW-TD-PU                  03A  OM 206A-0001          NDE-66    VT-3        NA                  0.000 /0.000              Emergency Feedwater Turbine Driven Pump, Class 3  0-ISIN4-121D-1.1                                                                              Support & Pad.
O1.Fl.40.0023                                                                                                                                                        F01.040.023 1-RCSR-FTR                    51B  OM 201-2135            NDE-66    VT-3        NA                  0.000 /0.000              Reactor Coolant Seal Return Filter. Component Class 2  0-ISIN4-101A-1.1                                                                              Support number is 1-51B-2-0-436G-H64. Calc 1-51-06/sht.1                                                                                No. OSC-1538, Page 93.
O1.Fl.40.0032                                                                                                                                                        F01.040.034 1-50-0-66A-RCPM-S6            50  0-66A                  NDE-66    VT-3        NA                  0.000 /5.000              Calculation No. OSC-0971-01-0006, Reactor Hyd Snubber              Class 1  0-ISIN4-100A-1.1                                                                              Coolant Pump 1A2 Motor Snubbers. Reference 0-66B                                                                                        PIP 0-096-1575. Inspect with F01.050.113.
O1.Fl.40.0087                                                                                                                                                        F01.040.041 0-19A-447F-H7101                19 O-SSF-41903-02        NDE-66    VT-3        CS                  0.250 / 42.000            Standby Shutdown Facility. Diesel Generator Rigid Support            Class 3  0-ISIN4-137D-1.3                                                                              Intake Silencer.
OM-351-121 O1.Fl.40.0088                                                                                                                                                        F01.040.042 0-19A-447F-H7102                19 O-SSF-41903-02        NDE-66    VT-3        CS                  0.250 / 42.000            Standby Shutdown Facility. Diesel Generator Rigid Support            Class 3  0-ISIN4-137D-1.3                                                                              Intake Silencer.
OM-351-121 O1.Fl.40.0089                                                                                                                                                        F01.040.043 0-19A-447F-H7119                19 O-SSF-41903-01        NDE-66    VT-3        NA                  0.625 / 48.000            Standby Shutdown Facility. Diesel Generator Rigid Support            Class 3  O-320-J6                                                                                      Exhaust Silencer. This support attachment is OM-351-75                                                                                    listed on 0-ISIN4-137D-1.3.
O1 .Fl.40.0090                                                                                                                                                        F01.040.044 0-19A-447F-H7120                19 O-SSF-41903-01        NDE-66    VT-3        NA                  0.625 /48.000              Standby Shutdown Facility. Diesel Generator Rigid Support            Class 3  O-320-J6                                                                                      Exhaust Silencer. This support attachment is OM-351-75                                                                                    listed on 0-ISIN4-137D-1.3.
Printed 07/17/08 Ick8302 v. 01/19/08                                                        SDQA Cat "C"                          Oconee 1 7/17/2008 5:22:22 PM      Page 49 of 50
 
0                                      This report includes all change        ough addendum ONSl-087 Oconee 1, 4th intervautage3 (EOC-24) '
Summary Num                                                    Insp Component ID / Type        System  ISO/DWG Numbers    Procedure Req          Mat            Sched ThicklDia    Cal Blocks Comments / HistoricalData Category      F-A O1.F1.40.0091                                                                                                                                                        F01.040.045 1-SRC-LATERAL                51A  O-0152-W-008          NDE-66    VT-3          NA                  0.000 / 0.000            Unit I Seal Return Cooler Lateral Restraint.
Class 2 0-ISIN4-101A-1.1 O1.F1.40.0092                                                                                                                                                        F01.040.046 I-SGA-LATERAL                  50  0-65D                  NDE-66    VT-3          NA                  0.000 / 0.000            Unit 1 Steam Generator A Lateral Support.
Class 2 0-65Y                                                                                        Drawing 0-65D, 065Y, 065V, and 0-65G 0-65V                                                                                        should be used for inspection of the Lateral support.
End of Report-
: v. 01/19/08 07/17/08 1ck8302 v.01/19/08                                                        SDQA  Cat "C"                        Oconee 1 7/17/2008 5:22:22 PM      Page 50 of 50 Printed 07/17/08lck8302 Printed                                                                                    SDQA Cat "C"                          Oconee 1 7/17/2008 5:22:22 PM      Page 50 of 50
 
4.0    Results Of Inspections Performed The results of each examination shown in the final Inservice Inspection Plan (Section 3 of this report) are included in this section. The completion date and status for each examination are shown. All examinations revealing reportable indications and any corrective action required as a result are described in further detail in Subsections 4.1 and 4.2. Corrective measures performed and limited examinations are described in further detail in Subsections 4.3 and 4.4.
The information shown below is a field description for the reporting format included in this section of the report:
Summary Number                ASME Section Xl Tables IWB-2500-1 (Class 1), IWC-2500-1 (Class 2), IWF-2500-1 (Class 1 and Class 2),
Augmented Requirements ID Number                =    Unique Identification Number Sys                      =    Component System Identification 0
Insp Date                =    Date of Examination Insp Status              =    CLR Clear REC Recordable REP Reportable Insp Limited            =    Indicates inspection was limited.
Coverage obtained is listed Geo. Ref.                    Y Yes (Geometric Reflector          N No applies only to UT)
Y Yes RFR (Relief Request)
N No Comments                      General and/or Detail Description EOC 24 Refueling Outage Report                                                  Page 1 of 3 Oconee Unit 1                                                                  Revision 0 Section 4                                                                      July 17, 2008
 
4.1    Reportable Indications EOC 24 (Outage 3) had one reportable indications during this report period. See paragraph 4.2 for corrective actions associated with the item that had a reportable indication.
4.2    Corrective Action Corrective action is action taken to resolve flaws and relevant conditions, including supplemental examinations, analytical evaluations, repair/ replacement activities, and corrective measures.
PIP 0-08-02115 was written to document boron deposits found during a visual examination (VT-1) on flange 1-51A-5-1B1-FLG (summary number #
O1 .B7.50.0007).The boron deposits found during the VT-1 examination were evaluated per NSD-322 and it was determined that there are no boric acid corrosion concerns because all target material was stainless steel material and is not susceptible to boric acid corrision. Plan Addenda ONS1-080 was written to schedule two additional sample examinations as required per Paragraph IWB-2430 of the 1998 Section Xl Code with the 2000 Addenda. The additional sample examinations were scheduled and performed during EOC-23. There will not be any surveillance inspections required per IWC-2420(b) because the bolting was not damaged.
4.3    Corrective Measures Corrective measures are actions (such as maintenance) taken to resolve relevant conditions, but not including supplemental examinations, analytical evaluations, and repair / replacement activities. Any corrective measures performed for examinations associated with this report period will be shown on the examination data sheets which are on file at the Duke's Corporate Office in Charlotte, North Carolina.
PIP 0-08-02634 was written to document evidence of leakage discovered during a VT-2 examination on summary number O1 .G1 1.1.00002. The examination was in the Unit 1 Reactor Vessel Head Penetrations area.
EOC 24 Refueling Outage Report                                                Page 2 of 3 Oconee Unit 1                                                                  Revision 0 Section 4                                                                      July 17, 2008
 
4.4    Limited Examinations Limited examinations (i.e., less than or equal to 90% of the required examination coverage obtained for surface and volumetric exams on welds or less than 100%
of the required examination area for Visual exams) identified during EOC 24 (Outage 2) are shown in the table below:
Summary Number Description of Limitation O1..B9.11.0053        Coverage limitation (37.50%)
* 01 .B9.11.0075        Coverage limitation (37.50%)
* O1 .C5.11.0027        Coverage limitation (75.00%)
* O1 .C5.11.0072        Coverage limitation (75.00%)
* O1.C5.11.0074        Coverage limitation (75.00%)
* O1.C5.11.0075        Coverage limitation (75.00%)
* O1.C5.11.0076        Coverage limitation (75.00%)
* O1.C5.21.0023        Coverage limitation (75.00%)
* O1.C5.21.0039        Coverage limitation (45.20%)
* O1 .C5.21.0043        Coverage limitation (42.30%) *
* PIP # 0-08-02894 was written to track the corrective action for limited coverage on UT examinations of welds that were inspected during 1EOC-24 for Unit 1.
EOC 24 Refueling Outage Report                                                Page 3 of 3 Oconee Unit 1                                                                Revision 0 Section 4                                                                    July 17, 2008
 
                                                                  .DUKE ENERGY CWPO ?A TION 0                                        QUALITY ASSURANCE 718CHNI CAL SERVICES                                                                            0 Scheduleworks                                          Inservice Inspection DatabaseMariagement System Inspection Result,s Oconee 1, 4th Interval, Outag e 3 (EOC-24)
Insp    Insp    Insp    Geo Summary No          Component ID                System  Date    Status  Limited    Ref    RFR Comment O1.B10.20.0002    1-51A-0-478A-H3C                51A  04/23/08  CLR      N        N      N  PT-08-046 O1.B12.50.0003    1-53A-CF-13                    53A  04/24/08  CLR      N        N      N  VT-08-1 11 01.12.60.0001    1-51A-18792-1-V-3                51A  04/18/08  CLR      N        Y      N  UT-08-032 Indication # 1-45' is a geometric reflector from the~weld root and indications # 2-600 and # 3-70o are geometric relfectors from the tubesheet.
01..B2.60.0002  1-51A-18792-1-V-5                51A  04/18/08  CLR      N        Y      N  UT-08-033 Indication # 1-45o is a geometric reflector from the weld root and indications # 2-600 and # 3-70o are geometric relfectors from the tubesheet.
01.B6.10.0021    1-RPV-26-203-21                      04/18/08  CLR      N        N      N  VT-08-082 O1 .B6.10.0022    1-RPV-26-203-22                      04/18/08  CLR      N        N      N  VT-08-083 01.B6.10.0023    1-RPV-26-203-23                      04/18/08  CLR      N        N      N  VT-08-084 01.16.10.0024    1-RPV-26-203-24                      04/18/08  CLR      N        N      N  VT-08-085 01.B6.10.0025    1-RPV-26-203-25                      04/18/08  CLR      N        N      N  VT-08-086 O1.B6.10.0026    1-RPV-26-203-26                      04/18/08  CLR      N        N      N  VT-08-087 O1 .B6.10.0027  1-RPV-26-203-62                      04/18/08  CLR      N        N      N  VT-08-088 Printed 7/17/2008 12:59:33 PM Ick8302 v. 01/01/08                              SDQA Cat "C"                    Oconee 1    7/17/2008 12:58:01 PM                        Page 1 of 26
 
Insp    Insp    Insp      Geo 0                                                  s Summary No          Component ID                System  Date  Status Limited    Ref    RFR Comment O1 .B6.10.0028    1-RPV-26-203-28                      04/18/08  CLR                N          VT-08-089 O1.B6.10.0029    1-RPV-26-203-29                      04/18/08  CLR                N          VT-08-090 O1 .B6.10.0030    1-RPV-26-203-30                      04/18/08  CLR                N          VT-08-091 O1.B6.10.0031    1-RPV-26-203-61                      04/18/08  CLR                N          VT-08-092 O.B6.10.0032      1-RPV-26-203-32                      04/18/08  CLR                N          VT-08-093 O1 .B6.10.0033    1-RPV-26-203-33                      04/18/08  CLR                N          VT-08-094 O1.B6.10.0034    1-RPV-26-203-65                      04/18/08  CLR                N          VT-08-095 O1.B6.10.0035    1-RPV-26-203-35                      04/18/08  CLR                N          VT-08-096 O1 .B6.10.0036    1-RPV-26-203-36                      04/18/08  CLR                N          VT-08-097 O1.B6.10.0037    1-RPV-26-203-37                      04/19/08  CLR                N          VT-08-098 O1.B6.10.0038    1-RPV-26-203-38                      04/19/08  CLR                N          VT-08-099 01 .B6.10.0039    1-RPV-26,203-39                      04/19/08 CLR                N          VT-08-1 00 O1 .B6.10.0040    1-RPV-26-203-40                      04/19/08 CLR                N          VT-08-1 01 O1 .B6.30.0021    1-RPV-25-203-21                      04/18/08 CLR                N          UT-08-027 Printed 7/17/2008 12:59:33 PM Ick8302 v. 01/01/08                              SDQA Cat "C"              Oconee 1 7/17/2008 12:58:01 PM Page 2 of 26
 
Insp    Insp  Insp      Geo Summary No          Component ID                System  Date  Status Limited    Ref    RFR Comment O1.B6.30.0022    1-RPV-25-203-22                      04/18/08 CLR                N      N  UT-08-028 01.B6.30.0023    1-RPV-25-203-23                      04/18/08 CLR                N      N  UT-08-029 O1.B6.30.0024    1-RPV-25-203-24                      04/18/08 CLR                N      N  UT-08-030 O1.B6.30.0025    1-RPV-25-203-25                      04/17/08 CLR                N      N  UT-08-015 O1.B6.30.0026    1-RPV-25-203-26                      04/17/08 CLR                N      N  UT-08-016 O1.B6.30.0027    1-RPV-25-203-27                      04/17/08 CLR                N      N  UT-08-017 O1.B6.30.0028    1-RPV-25-203-63                      04/17/08 CLR                N      N  UT-08-018 O1.B6.30.0029    1-RPV-25-203-29                      04/17/08 CLR                N      N  UT-08-019 O1.B6.30.0030    1-RPV-25-203-30                      04/17/08 CLR                N      N  UT-08-020 O1.B6.30.0031    1-RPV-25-203-61                      04/17/08 CLR                N      N  UT-08-021 O1.B6.30.0032    1-RPV-25-203-32                      04/17/08 CLR                N      N  UT-08-022 O1.B6.30.0033    1-RPV-25-203-33                      04/17/08 CLR                N      N  UT-08-023 O1.B6.30.0034    1-RPV-25-203-34                      04/17/08 CLR                N      N  UT-08-024 O1.B6.30.0035    1-RPV-25-203-35                      04/17/08 CLR                N      N  UT-08-025 Printed 7/17/2008 12:59:33 PM Ick8302 v. 01/01/08                              SDQA Cat "C"              Oconee 1 7/17/2008 12:58:01 PM Page 3 of 26
 
Insp      Insp  Insp      Geo 0
Summary No        Component ID                System  Date    Status Limited    Ref    RFR Comment 01.B6.30.0036    1-RPV-25-203-36                      04/17/08    CLR      N        N      N  UT-08-026 01 .B6.30.0037  1-RPV-25-203-37                      04/19/08    CLR      N        N      N  UT-08-034 01.B6.30.0038    1-RPV-25-203-38                      04/19/08    CLR      N        N      N  UT-08-035 01.B6.30.0039    1-RPV-25-203-65                      04/19/08    CLR      N        N      N  UT-08-036 01.B6.30.0040    1-RPV-25-203-40                      04/19/08    CLR      N        N      N  UT-08-037 01 .B6.50.0002  1-RPV-WASH-BUSH                      04/18/08    CLR      N        N      N  VT-08-1 10 Randy Baggett and Clint Leatherman also examined some of the Washers for this summary number.
All of the required washers for this Summary number were examined.
01 .B7.30.0001  1-SGA-UMW-STUDS                      04/13/08    CLR      N        N      N  VT-08-102 01 .B7.30.0005  1-SGA-UHHC-STUDS                    04/13/08    CLR      N        N      N  VT-08-103 01 .B7.50.0001  1-PZR-RC4-STUDS                      04/13/08    CLR      N        N      N  VT-08-104 01.B7.50.0002    1-PZR-RC66-STUDS                    04/13/08    CLR      N        N      N  VT-08-105 01.B7.50.0003    1-PZR-RC67-STUDS                    04/27/08    CLR      N        N      N  VT-08-119 This exam is for additional sample per IWB-2430. (do not count in percentages for 1EOC-24) 01.137.50.0004    1-PZR-RC68-STUDS                    04/27/08 'CLR        N        N      N  VT-08-120 This exam is for additional sample per IWB-2430. (do not count in percentages for 1EOC-24)
Printed 7/17/2008 12:59:34 PM Ick8302 v. 01/01/08                              SDQA Cat "C"                    Oconee 1 7/17/2008 12:58:01 PM                      Page 4 of 26
 
Insp    Insp  Insp      Geo
                                                                                                                                                                        .O Summary No          Component ID              System  Date  Status Limited    Ref    RFR Comment 01 .B7.50.0005    1-51A-4-1A1-FLG                51A 04/15/08  CLR      N        N      N  VT-08-036 01.B7.50.0006    1-51A-4-1A2-FLG                51A 04/15/08  CLR      N        N      N  VT-08-037 01.B7.50.0007    1-51A-5-1B1-FLG                51A 04/15/08  REP      N        N      N  VT-08-038 PIP 0-08-02115 was written to address the boron found at the top of the flange.
Plan addenda ONS1-080 was written to schedule 01..B7.50.0003 and 01..B7.50.0004 for additional samle exams per IWB-2430.
No supplemental exams for the bolting on the 01 .B7.50.0007 item per IWB-2420 because the bolting was not damaged.
Boron leakage was evaluated per NSD-322 and it was determined that there are no boric acid corrision concerns because all target material is SS material and is not susceptible to boric acid corrision.
01..B7.50.0008    1HP-255-1 B2-FLG                51A 04/15/08  CLR      N        N      N  VT-08-039 01..B9.11.0025    1SGA-W2                          50 04/23/08  CLR    N          N      N  MT-08-011 50 04/23/08  CLR    N          N      N  UT-08-056 01..B9.11.0032    1-PSL-1                          50 04/20/08  CLR    N          N      N  PT-08-039 50 04/20/08 CLR      N          N      N  UT-08-048 O1.B9.11.0048    1RC-289-8V                      50 04/23/08 CLR      N          N      N  MT-08-012 50 04/23/08 CLR      N          N      N  UT-08-057 01..B9.11.0049  1-PIA2-4                          50 04/23/08 CLR      N          N      N  MT-08-013 50  04/23/08 CLR      N          N      N  UT-08-058 O1 .B9.11.0053  1-PIB2-9                        50  04/19/08 CLR      N          N      N  PT-08-030 Printed 7/17/2008 12:59:34 PM Ick8302 v. 01/01/08                            SDQA Cat "C"                    Oconee 1 7/17/2008 12:58:01 PM                          Page 5 of 26
 
Insp    Insp  Insp      Geo                                                                                        )
Summary No          Component ID                System  Date    Status Limited    Ref    RiFR Comment 01.B9.11.0053    1-PIB2-9                        50  04/20/08  CLR  37.50%      N      Y  UT-08-049 PIP 0-08-02894 was written to document and determine the corrective action for the limited coverage achieved for this exam.
50  04/20/08  CLR      N        N      N  UT-08-050 Best effort exam of the upper 2/3 of weld to supplement the coverage and to help justify the limited exam.
01.139.11.0075    1-PDB2-1                        50  04/28/08  CLR      N        N      N  PT-08-061 50  04/29/08  CLR      N        N      N  UT-08-081 Best effort exam of the upper 2/3 of weld to supplement the coverage and to help justify the limited exam.
50  04/29/08,  CLR  37.50%      N      Y  UT-08-082 PIP 0-08-02894 was written to document and determine the corrective action for the limited coverage achieved for this exam.
01.139.11.0076~ 1-PDB2-3                          50  04/28/08  CLR      N        N      N-  MT-08-020 50  04/29/08  CLR      N        N      N  UT-08-078 01.139.11.0077    1-PD132-4                        50  04/28/08  CLR      N        N      N  MT-08-021 50  04/29/08  CLR      N        N      N  UT-08-079 01..B9.21.0009    1-51A-07-14E                    51A  04/18/08  CLR      N        N      N  PT-08-029 O1.B9.21.0010    1-51A-07-18E                    51A  04/23/08  CLR      N        N      N  PT-08-047 O1.B9.21.0011    1-51A-07-22E                    51A  04/23/08  CLR      N        N      N  PT-08-044 Printed 7/17/2008 12:59:34 PM Ick8302 v. 01/01/08                              SDQA Cat "C"                      Oconee 1 7/17/2008 12:58:01 PM                      Page 6 of 26
 
0 Insp    Insp  Insp      Geo Summary No          Component ID                System  Date    Status Limited    Ref    RFR Comment O1.B9.21.0015    1-51A-134A-6                    51A  04/18/08  CLR      N        N      N  PT-08-025 O1.B9.21.0018    1-51A-137-1B                    51A  04/18/08  CLR      N        N      N  PT-08-026 O1.B9.21.0019    1-51A-137-27                    51A  04/18/08  CLR      N        N      N  PT-08-027 O1..B9.21.0027    1-PIB2-11                        50  04/18/08  CLR      N        N      N  PT-08-028 O1.B9.21.0032    1-PSP-4                          50  04/21/08  CLR      N        N      N  PT-08-038 O1.B9.21.0157    1-51A-07-25E                    51A  04/23/08  CLR      N        N      N  PT-08-045 O1.B9.32.0006    1-PIB2-10                        50  04/18/08  CLR      N        N      N  MT-08-005 O1.B9.40.0015    1RC-127-3                        50  04/21/08  CLR      N        N      N  PT-08-033 01..B9.40.0016    1RC-127-8BA                      50  04/21/08  CLR      N        N      N  PT-08-034 O1.C1.30.0001    1-SGB-W69                        03  04/29/08  CLR    90.70%      N      Y  UT-08-080 Limited coverage acceptable per Code Case N-460.
01 .C1.30.0007    1-RCSRCA-SH-TS-1                51A  03/28/07  CLR      N        N      N  PT-08-022 01 .C1.30.0008    1-RCSHCA-SH-TS-2                51A  03/29/07  CLR      N        N      N  PT-08-023 O1 .C3.10.0001    1-RCSR-COOLER-A                51 B 03/28/07  CLR      N        N      N  PT-08-024 O1 .C3.20.0002    1-01A-0-550-R7                  01A  04/29/08- CLR      N        N      N  MT-08-022 Printed 7/17/2008 12:59:34 PM Ick83O2 v. 01/01/08                              SDQA Cat "C"                  Oconee 1 7/17/2008 12:58:01 PM    Page 7 of 26
 
Insp    Insp  Insp      Geo 0
Summary No          Component ID                System  Date  Status Limited    Ref    RFR  Comment 01.03.20.0013    1-51-0-436H-SR17                51  04/22/08  CLR      N        N      N'  PT-08-040 01.C3.20.0022    1-53B-5-0-444-H6                53B  02/08/08 CLR      N        N      N  PT-08-008 O1.C3.20.0023    1-54A-0-439A-R 16              54A  02/11/08 CLR      N        N      N  PT-08-011 O1 .C3.20.0025    1-54A-3-0-436D-R27              54A  02/08/08 CLR      N        N      N  PT-08-009 O1.C3.20.0026    1-54A-3-0-439A-R1 1            54A  02/04/08 CLR      N        N      N  PT-08001 O1.C3.20.0029    1-56-4-0-437B-H1                56  02/11/08 REC      N        N      N  PT-08-012 The recordable indication is a rounded indication .200 inches in diameter that is acceptable per IWC-3512 and IWB-3514 (table IWB-3514-2).
O1.C3.20.0222    1-03A-4-PEN # 50                03A  04/17/08 CLR      N        N      N  PT-08-020 O1.C3.20.0225    1SF-1 07-PEN # 56                56  04/17/08 CLR      N        N      N  PT-08-021 O1.C5.11.0027    1LP-124-21                      53A  02/04/08 CLR      N        N      N  PT-08002 53A  02/06/08 CLR    75.00%      N      Y  UT-08-001 PIP 0-08-02894 was written to document and determine the corrective action for the limited coverage achieved for this exam.
O1.C5.11,0068    1LP-208-12                      53A  04/27/08 OLR      N        N      N  PT-08-057 53A  04/27/08 CLR      N        N      N  UT-08-070 O1.C5.11.0069    1LP-208-13                      53A  04/27/08 CLR      N        N      N  PT-08-058 Printed 7/17/2008 12:59:34 PM Ick8302 v. 01/01/08                              SDQA Cat "C"                    Oconee 1 7/17/2008 12:58:01 PM                          Page 8 of 26
 
Insp    Insp  Insp Geo0                                                                              s Summary No          Component ID              System  Date  Status Limited    Ref    RFR Comment 01.C5.11.0069    1 LP-208-13                    53A 04/27/08  CLR      N        N      N  UT-08-074 01.C5.11.0070    1LP-208-14                      53A 04/27/08  CLR      N        N      N  PT-08-059 53A 04/27/08  CLR      N        N      N  UT-08-075 O1.C5.11.0071    1 LP-208-15                    53A 04/27/08  CLR      N        N      N  PT-08-060 53A 04/27/08 .CLR      N        N      N  UT-08-076 O1.C5.11.0072    1 LP-208-19                    53A 04/26/08  CLR      N        N      N  PT-08-049 53A 04/27/08  CLR  75.00%      N      Y  UT-08-066 PIP 0-08-02894 was written to document and determine the corrective action for the limited coverage achieved for this exam.
O1.C5.11.0073    1LP-208-2                      53A 04/25/08  CLR      N        N      N  PT-08-048 53A 04/25/08  CLR      N        N      N  UT-08-064 O1.C5.11.0074    1LP-208-20                      53A 04/26/08  CLR      N        N      N  PT-08-050 53A 04/27/08  CLR  75.00%      N      Y  UT-08-067 PIP 0-08-02894 was written to document and determine the corrective action for the limited coverage achieved for this exam.
O1.C5.11.0075    1LP-208-3                      53A 04/26/08  CLR      N        N      N  PT-08-051 53A 04/27/08  CLR  75.00%      N      Y  UT-08-068 PIP 0-08-02894 was written to document and determine the corrective action for the limited coverage achieved for this exam.
Printed 7/17/2008 12:59:34 PM Ick8302 v. 01/01/08                            SDQA Cat "C"                    Oconee 1 7/17/2008 12:58:01 PM                      Page 9 of 26
 
Insp  Insp    Insp      Geo 0
Summary No          Component ID              System    Date  Status Limited    Ref    RFR Comment O1.C5.11.0076    1LP-208-4                      53A  04/26/08 CLR      N        N      N  PT-08-052 53A  04/27/08 CLR    75.00%      Y      Y  UT-08-069 PIP 0-08-02894 was written to document and determine the corrective action for the limited coverage achieved for this exam.
Indication # 1 was determined to be geometry.
O1.C5.11.0077    1LP-208-5                      53A .04/26/08 CLR      N        N      N  PT-08-053 53A  04/27/08 CLR      N        N      N  UT-08-077 O1.C5.11.0078    1LP-208-6                      53A  04/26/08 CLR      N        N      N  PT-08-054 53A  04/27/08 CLR      N        N      N  UT-08-071 O1.C5.11.0079    1LP-208-7                      53A  04/26/08 CLR      N        N      N  PT-08-055 53A  04/27/08  CLR      N        N      N  UT-08-072 O1.C5.11.0080    1LP-208-8                      53A  04/26/08 CLR      N        N      N  PT-08-056 53A  04/27/08 CLR      N        N      N  UT-08-073 O1.C5.21.0003    1-51 A-03-93BA                  51A  02/05/08  CLR  95.80%      N      N  PT-08-016 51A  02/07/08 CLR    91.70%      N      N  UT-08-009 O1.C5.21.0007    1HP-192-4                      51A  02/04/08 0LR      N        N      N  PT-08003 51A  02/06/08  CLR      N        N      N  UT-08-005 Printed 7/17/2008 12:59:34 PM Ick8302 v. 01/01/08                              SDQA Cat "C"                    Oconee 1 7/17/2008 12:58:01 PM                    Page 10 of 26
 
0                                        Insp    Insp    Insp      Geo 0
Summary No          Component ID                System  Date    Status Limited    Ref    RFR Comment O1.C5.21.0009    1-51A-124-2                    51A  02/04/08  CLR      N        N      N  PT-08004 51A  02/06/08  CLR      N        N      N  UT-08-004 O1.C5.21.0019    1HP-180-97E                    51A  04/21/08  CLR      N        N      N  PT-08-036 51A  04/21/08  CLR      N        N      N  UT-08-051 O1.C5.21.0023    1HP-282-76A                    51A  02/12/08  CLR      N        N      N  PT-08-013 51A  02/12/08  CLR  75.00%      N      Y  UT-08-007 PIP 0-08-02894 was written to document and determine the corrective action for the limited coverage achieved for this exam.
O1.05.21.0032    1-51A-02-64B                    51A  04/22/08  CLR      N        N      N  PT-08-041 51A  04/22/08  CLR      N        N      N  UT-08-059 O1.C5.21.0036    1-51A-03-93BB                  51A  02/06/08  CLR      N        N      N  PT-08005 51A  02/07/08  CLR      N        N      N  UT-08-010 O1.C5.21.0039    1HP-193-13                      51A  02/05/08  CLR      N        N      N  PT-08006 51A  02/07/08. CLR  45.20%      N      Y  UT-08-011 PIP 0-08-02894 was written to document and determine the corrective action for the limited coverage achieved for this exam.
O1.C5.21.0043    1HP-367-21                      518  02/08/08  CLR      N        N      N  PT-08-010 Printed 7/17/2008 12:59:34 PM Ick8302 v. 01/01/08                              SDQA Cat "C"                    Oconee 1 7/17/2008 12:58:01 PM                    Page 11 ofý26
 
Insp    Insp  Insp      Geo 0                                                                                  0 Summary No          Component ID              System    Date  Status Limited    Ref    RFR Comment O1 .C5.21.0043    1HP-367-21                      51B  02/11/08  CLR  42.30%      N      Y  UT-08-006 PIP 0-08-02894 was written to document and determine the corrective action for the limited coverage achieved for this exam.
O1.C5.21.0047    1-51A-01-27A                    51A  02/12/08  CLR      N        N      N  PT-08-014 51 A 02/12/08  CLR      N-      N      N  UT-08-008 O1.C5.21.0052    1-51 A-02-30B                  51A  04/22/08  CLR      N        N      N  PT-08-042 51A  04/22/08  CLR      N        Y      N  UT-08-060 Indication # 1 was determined to be from the root geometry.
O1.C5.30.0002    1-51 B- 10-49                  51B  02/05/08 CLR      -N        N      N  PT-08007 O1 .C5.30.0005    1-51A-136-27                    51A  04/21/08 CLR        N        N      N  PT-08-037 O1 .C5.41.0008    1-53B-07-23                    53B  02/12/08 CLR      .N        N      N  PT-08-015 O1.C5.41.0010    1-51B-1-12AA                    51B  04/22/08 CLR        N        N      N  PT-08-043 O1.C5.51.0002    1MS-073-13B                    01A  04/21/08 CLR        N        N      N  MT-08-008 01A  04/21/08 CLR        N        Y      N  UT-08-052 Indication #.1 was determined to be an ID geometric reflector due to weld root geometry.
O1.C5.51.0004    1-MS1B-B                        01A  04/21/08 CLR        N        N      N  MT-08-009 01A  04/21/08 CLR        N        Y      N  UT-08-053 Indication # 1, 2, and 3 were determined to be ID geometric reflectors.
Printed 7/17/2008 12:59:34 PM Ick8302 v. 01/01/08                              SDQA Cat "C"                    Oconee 1 7/17/2008 12:58:01 PM                          Page 12 of 26
 
Insp    Insp  Insp      Geo 0
Summary No          Component ID                System  Date  Status Limited    Ref    RFR Comment O1.C5.51.0014      1MS-068-35V                    01A  04/21/08  CLR    N        N      N  MT-08-010 01A  04/21/08  CLR    N        N      N  UT-08-054 O1.C5.51.0015      1-MS21A-D                      01A  04/18/08  CLR    N        N      N  MT-08-006 01A  04/18/08  CLR    N        Y      N  UT-08-031 Indication # 1 was determined to be an ID geometric reflector due to a backing ring.
O1.C5.51.0026      1-FWD64-E                        03  04/16/08  CLR    N        N      N  MT-08-004 03  04/16/08  CLR    N        Y      N  UT-08-014 Indications # 1, 2, 4, and 5 are geometric reflectors due to backing ring. Indication
                                                                                              # 3 is a geometric reflector due to counterbore geometry.
O1.C5.51.0031      1CC-136-81B                      55  02/05/08  CLR    N        N      N  MT-08-001 55  04115/08  CLR    N        N      N  UT-08-012 O1.C5.51.0041      1LPSW-345-19                    14B  02/05/08  CLR    N        N      N  MT-08-002 14B  02/07/08  CLR    N        N      N  UT-08-003 O1.C5.51.0047      1LPS-911-37                    14B  02/05/08  CLR    N        N.      N  MT-08-003 This weld was listed (and examined) previously as 1-LPSW-346-37 on weld iso 1-LPSW-346 until it was transferred to iso 1LPS-91 1.
14B  02/07/08  CLR    N        N      N  UT-08-002 O1.C5.51.0061      1-14-232-1-11                  14B  04/25/08  CLR    N        N      N  MT-08-019 Printed 7/11ý/2008 12:59:34 PM Ick8302 v. 01/01/08                            SDQA Cat "C"                    Oconee 1 7/17/2008 12:58:01 PM                          Page 13 of 26
 
Insp    Insp  Insp Geo                                                                                    0 Summary No          Component ID              System'  Date  Status Limited    Ref    RFR Comment O1.C5.51.0061    1-14-232-1-11                  14B  04/25/08  CLR      N        Y      N  UT-08-065 Indications # 1 and 2 are 3600 intermittant reflectors due to root geometry.
O1.C5.81.0003    1-MS23B-C                      01A  04/18/08  CLR                      N  MT-08-007 O1.D1.10.0017    0-19A-447F-H7101                19  02/15/07  CLR                      N  VT-08-040 O1.D1.10.0018    0-19A-447F-H7102                  19  02/15/07  CLR                      N  VT-08-041 O1.Dl.10.0019    0-19A-447F-H7119                  19  02/15/07  CLR                      N  VT-08-042 O1.Dl.10.0020    0-19A-447F-H7120                  19  02/15/07  CLR                      N  VT-08-043 O1.Dl.20.0014    1-03A-1 400B-H59            03A  02/19/08  CLR                        N  VT-08-044 O1 .Dl.20.0021    1-13-0-400B-JEJ-1901            13  02/12/08  REC                        N  VT-08-001 The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service. Work Order 951271 was written to further assess the discrepancies and Work Order 952517 was written to correct problems.
O1 .Dl.20.0023    1-144B-1 400B-H31            14B  02/12/08  CLR      N        N      N  VT-08-045 O1.Dl.20.0094    1-03A-401B-DE049                03A  02/19/08  REC      N        N      N  VT-08-002 The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service.
O1.D1.20.0248    0-19A-447F-H7123                  19  02/15/07  CLR      N        N      N  VT-08-046 O1.D1.20.0249    0-19A-447F-H7094                  19  02/15/07  CLR      N        N      N  VT-08-047 Printed 7/17/2008 12:59:34 PM Ick8302 v. 01/01/08                              SDQA Cat "C"                    Oconee 1 7/17/2008 12:58:01 PM                        Page 14 of 26
 
Insp    Insp  Insp      Geo Summary No          Component ID              System    Date  Status Limited    Ref    RFR Comment O1 .D1.20.0250    0-19A-447F-H7103                  19 02/23/07  CLR      N        N      N  VT-08-048 O1.F1.10.0001    1-51A-0-479A-H11B                51A 05/01/08  REC      N        N      N  VT-08-126 The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service.
O1.F1.10.0004    1-51A-0-478A-H3C                -51A 04/22/08  REC      N        N      N  VT-08-106 The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service.
O1.F1.10.0007    1-51A-0-479A-H9A                51A 04/17/08  REC      N        N      N  VT-08-071 The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service.
O1.F1.11.0001    1-51A-0-479A-H1OB                51A 05/01/08  CLR      N        N      N  VT-08-127 O1.F1.11.0002    1-51A-0-478A-H2C                51A 05/22/08  REC      N        N      N  VT-08-132 The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service.
O1.F1.12.0006    1-51A-0-478A-HlC                51A 05/22/08  REC    N          N      N  VT-08-133 The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service. Work Order 954580 was written to correct problem.
O1.F1.12.0009    1-53A-0-478A-H5B                53A 04/26/08  CLR    N          N      N  VT-08-117 O1.F1.20.0002    1-01A-0-550-H2                  01A 04/29/08  REC    N          N          VT-08-121 The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service..
Printed 7/17/2008 12:59:34 PM Ick8302 v. 01/01/08                              SDQA Cat "C"                  Oconee 1 7/17/2008 12:58:01 PM                        Page 15 of 26
 
Insp    Insp  Insp      Geo 0                                                                                0 Summary No          Component ID              System  Date  Status Limited    Ref    RFR Comment O1 .Fl.20.0007    1-14-478E-H6014                  14 04/26/08  REC      N        N      N  VT-08-122 The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service.
O1.F1.20.0013    1-51-0-435C-SR4                51  01/23/08  REC      N        N      N  VT-08-007 The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service.
O1.F1.20.0014    1-51-0-435C-SR5                51* 01/23/08  REC      N        N      N  VT-08-008 The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service.
O1.F1.20.0016    1-51-0-436D-SR10                51  02/27/07  REC    N          N      N  VT-08-009 The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service.
O1.F1.20.0017    1-51-0-436H-SR19                51  04/30/08  REC    N          N      N  VT-08-123 The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service.
O1.F1.20.0020    1-51-0-436D-SR7                51  02/28/07  REC    N          N      N  VT-08-010 The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service.
O1.F1.20.0028    1-51A-1-0-444-H1                51A 02/28/07  CLR    N          N      N  VT-08-052 O1.F1.20.0043    1-53B-5-0-444-H6                53B 02/13/08  REC    N          N      N  VT-08-011 The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service.
015F1.20.0045    1-538-5-0-439-R14              53B 02/21/08  CLR    N          N      N  VT-08-053 Printed 7/17/2008 12:59:34 PM Ick8302 v. 01/01/08                            SDQA Cat "C"                  Oconee 1 7/17/2008 12:58:01 PM                        Page 16 of 26
 
Insp    Insp  Insp      Geo 0
Summary No          Component ID                System  Date  Status Limited    Ref    RFR Comment O1 .Fl.20.0047    1-53B-6-0-439C-H 13              53B 01/09/08  REC    N        N      N  VT-08-003 The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service.
O1.F1.20.0048    1-54A-435B-DE-05                54A  02/21/08  REC    N        N      N  VT-08-012 The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service.
O1.F1.20.0055    1-56-4-0-437B-H11                56  02/13/08  REC    N        N      N  VT-08-013 The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service. Work Order # 00949807 was written to correct problems.
O1.F1.21.0002    1-03A-0-439A-DE068              03A  02/21/08  REC    N        N      N  VT-08-014 The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service.
O1,F1.21.0003    1-14-0-480A-H21C                14  05/02/08  REC    N        N      N  VT-08-128 The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service.
O1.F1.21.0005    1-14-0-479A-H20A                14  05/02/08  REC    N        N      N  VT-08-129 The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service.
O1.F1.21.0014    1-51-0-436H-SR17                51  04/30/08  REC    N        N      N  VT-08-124 The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service.
O1.F1.21.0017    1-51A-0-444-H114                51A  01/23/08  CLR    N        N      N  VT-08-015 Printed 7/17/2008 12:59:34 PM Ick8302 v. 01/01/08                            SDQA Cat "C"                    Oconee 1 7/17/2008 12:58:01 PM                      Page 17 of 26
 
0                                      Insp    Insp nsp      Geo I
Summary No          Component ID              System  Date    Status Li, mited    Ref    RFR Comment 01 .Fl.21.0028    1-53B-2-0-436E-H7              53B 01/23/08  REC        N        N      N  VT-08-016 The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service.
O1.F1i21.0032    1-54A-3-0-439A-R 11            54A 02/06/08  CLR        N        N      N  VT-08-055 O1.Fl.21.0077    1-53B-0-439A-DE054              53B 02/21/08  REC        N        N      N  VT-08-017 The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service.
01.F71.21.0192    1-03A-4-PEN # 50                03A 04/14/08  CLR        N        N      N  VT-08-056 O1 .Fl.21.0195    1SF-1 07-PEN # 56                56 04/17/08  CLR        N        N      N  VT-08-072 O1 .Fl.22.0005    1-01A-1-1-0-401A-H7            01A 02/28/08  CLR        N        N      N  VT-08-057 O1 .F1.22.0006    1-01A-0-550-R7                  01A 04/27/08  REC        N        N      N  VT-08-118 The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service.
O1 .Fl.22.0019    1-53A-0-479A-H5B                53A 04/15/08  CLR        N        N      N  VT-08-049 O1 .Fl.22.0028    1-54A-3-0-439A-H25A            54A 02/28/08  CLR        N        N      N  VT-08-050 O1 .Fl.30.0003    1-03-0-551 -Ri 1                03 04/15/08. REC        N        N      N  VT-08-034 The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service.
O1 .Fl.30.0021    1-03A-1-0-400B-H50              03A 02/12/08  REC        N        N      N  VT-08-018 The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service.
Printed 7/17/2008 12:59:34 PM Ick8302 v. 01/01/08                                SDQA Cat "C"                  Oconee 1 7/17/2008 12:58:01 PM                        Page 18 of 26
 
Insp  Insp    Insp      Geo 0
Summary No          Component ID                System  Date  Status Limited    Ref    RFR Comment O1 .Fl.30.0022    1-03A-1-0-400B-H59              03A  02/19/08 CLR.      N        N      N  VT-08-058 O1 .Fl.30.0023    1-03A-1 400A-H34            03A  02/19/08 REC      N        N      N  VT-08-019 The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service. Work Order # 00949124 was written to correct problems.
O1 .Fl.30.0026    2-03A-1 401 B-DE007            03A  02/19/08 CLR      N        N      N  VT-08-059 01 5F1.30.0027    2-03A-1-0-1401B-SR16            03A  02/19/08 CLR      N        N      N  VT-08-060 01 5F1.30.0039    1-14B-0-436L-ASR14              14B  01/09/08 REC      N        N      N  VT-08-004 The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service.
O1.F1.30.0040    1-14B-439B-DE009                14B  02/28/08 REC      N        N      N  VT-08-020 The discrepancies that were found were reviewed by civil engineering and the support was found tobe acceptable for service.
O1.F1.30.0051    1-14B-437A-SR60                14B  01/11/08 REC      N        N      N  VT-08-021 The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service. Work Order # 00947446 was written to correct problems.
O1.F1.30.0052    2-14B-1400A-DE144                148  02/12/08 CLR      N        N      N  VT-08-061 O1.F1.30.0058    1-56-443-H5106                  56  02/21/08 CLR      N        N      N  VT-08-062 O1.F1.30.0064    0-SSW-448K-H7362(A)              SSW  01/09/08 CLR      N        N      N  VT-08-051 O1.Fl.30.0222    1-03A-4018-DE049                03A  02/19/08 CLR      N        N      N  VT-08-063 Printed 7/17/2008 12:59:34 PM Ick8302 v. 01/01/08                              SDQA Cat "C"                    Oconee 1 7/17/2008 12:58:01 PM                      Paoe 19 of 26
 
9                                        Insp    Insp  Insp      Geo Summary No          Component ID              System    Date  Status Limited    Ref    RFR Comment O1.F1.30.0584    0-19A-447F-H7094                  19 02/15/07  REC    N          N      N  VT-08-022 The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service. Work Order # 00948996 was written to correct problems.
O1.F1.30.0585    0-19A-447F-H7103                  19 02/23/07  CLR    N          N      N  VT-08-054 O1.F1.31.0017    1-13-0-400B-JEJ-1901            13  02/12/08  REC    N          N      N  VT-08-023 The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service. Work Order 951271 was written to further assess the discrepancies and Work Order 952517 was written to correct problems.
O1.F1.31.0024    1-14B-436D-DE063                14B  01/23/08  CLR    N          N      N  VT-08-064 O1.F1.31:0025    1-56-437B-H5110                  56  01/09/08  REC    N          N      N  VT-08-024 The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service. Work Order # 00949021 was written to correct problems.
O1.Fl.31.0058    1-14B-0-400B-SR34              14B  02/19/08  REC    N          N      N  VT-08-025 The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service.
O1.F1.31.0213    0-19A-447F-H7118                  19  02/23/07  REC    N          N      N  VT-08-026 The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service. Work Order # 00946538 was written to correct problems.
O1.F1.32.0001    1-01A-4-1-0-401A-H2            01A  02/28/08  REC    NN                N  VT-08-027 The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service.
Printed 7/17/2008 12:59:34 PM Ick8302 v. 01/01/08                              SDQA Cat "C"                    Oconee 1 7/17/2008 12:58:01 PM                      Page 20 of 26
 
Insp    Insp  Insp      Geo 0
Summary No          Component ID                System  Date  Status Limited    Ref    RFR Comment O1 .Fl.32.0007    1-03A-1 439B-H21            03A  01/09/08  REC    N        N      N  VT-08-005 The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service.
01.Fl.32.0017    1-14B-437A-DE060                14B 02/27/07  REC    N        N      N  VT-08-028 The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service.
O1.F1.32.0019    1-14B-1-0-400B-H31              14B 02/12/08  REC    N        N      N  VT-08-006 The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service.
O1.F1.32.0140    0-19A-447F-H7123                  19 02/15/07  CLR    N        N      N  VT-08-065 01.F1.40.0010    1-EFDW-MD-PU-A                  03A  02/06/08  CLR    N        N      N  VT-08-066 O1.F1.40.0011    1-EFDW-PT                      03A  02/06/08  REC    N        N      N  VT-08-029 The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service.
O1.F1.40.0012    1-EFDW-TD-PU                    03A  02/06/08  CLR    N        N      N  VT-08-067 O1.F1.40.0023    1-RCSR-FTR                      51B  05/22/08  REC    N        N      N  VT-08-131 The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service.
01.F1.40.0032    1-50-0-66A-RCPM-S6              50  04/24/08  REC    N        N      N  VT-08-112 The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service.
Printed 7/17/2008 12:59:34 PM Ick8302 v. 01/01/08                            SDQA Cat "C"                  Oconee 1 7/17/2008 12:58:01 PM                        Page 21 of 26
 
Insp    Insp  Insp      Geo 0
Summary No          Component ID                System  Date  Status Limited    Ref    RFR Comment 01 .F1.40.0087  0-19A-447F-H7101                  19 02/15/07  REC    N        N      N  VT-08-030 The-discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service. Work Order # 00949005 was written to correct problems.
O1 .Fl.40.0088  0-19A-447F-H7102                  19 02/15/07  REC    N        N      N  VT-08-031 The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service. Work Order # 00949015 was written to correct problems.
O1.F1.40.0089    0-19A-447F-H7119                  19 02/15/07  REC    N        N      N  VT-08-032 The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service. Work Order # 00946980 was written to correct problems.
O1.F1.40.0090    0-19A-447F-H7120                  19 02/15/07  REC    N        N      N  VT-08-033 The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service.
O1.F1.40.0091    1-SRC-LATERAL                  51A  03/28/07  CLR    N        N      N  VT-08-068 O1.F1.40.0092    1-SGA-LATERAL                    50  05/22/08  REC    N        N      N  VT-08-130 The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service.
O1.G1.1.0001    1-RCP-1A1                        50  01/08/08  CLR    N        N      N  MT-N/A 50  01/07/08  CLR    N        N      N  UT-N/A Printed 7/17/2008 12:59:34 PM Ick8302 v. 01/01/08                            SDOA Cat "C"                    Oconee 1 7/17/2008 12:58:01 PM                      Page 22 of 26
 
Insp    Insp  Insp Geo0 Summary No          Component ID              System  Date  Status Limited    Ref    RFR Comment O1 .G11.1.0002    1-RPV-HEAD -PEN                  50 04/27/08  REP      N        N      N  VT-08-125 Evidence of leakage was detected during this examination. PIP 0-08-02634 was written to document the leakage found during this examination. The leakage was determined to be coming from a threaded connection on the CC header feeding the stator cooling water jacket for CRDM 54. The leak was repaired under Work Order 01807080 and all CC system deposits were removed from the head under Work Order 01787093-02. There was no degredation seen on.any of the closure head components and the head was determined to be accptable for service.
O1 .G13.1.0026    1RC-269-125V                    50 04/13/08  CLR                          VT-08-073 O1 .G13.1.0027    1-50-4-125                      50 04/13/08  CLR                          VT-08-074 O1 .G13.1.0028    1-50-4-143                      50 04/13/08  CLR                          VT-08-075 O1 .G13.1.0029    1-50-4-131                      50 04/13/08  CLR                          VT-08-076 O1 .G13.1.0030    1-50-4-135                      50 04/13/08  CLR                          VT-08-077 O1 .G13.1.0031    1-50-4-150                      50 04/13/08  CLR                          VT-08-078 O1.G13.1.0032    1RC-273-143V                    50 04/13/08 CLR                            VT-08-079 O1.G13.1.0033    1-50-4-44A                      50 04/13/08 CLR                            VT-08-080 O1.G14.1.0002    1-PZR-HTR PLATES                50 04/14/08 CLR                            VT-08-069 O1 .G14.1.0003    1-PZR-HTR SLEEVES                50 04/14/08 CLR                            VT-08-070 O1 .G4.1.0005    1HP-255-6                      51A 04/16/08 CLR                            UT-08-039 Printed 7/17/2008 12:59:34 PM Ick8302 v. 01/01/08                            SDQA Cat "C"                    Oconee 1 7/17/2008 12:58:01 PM                      Page 23 of 26
 
Insp    Insp  Insp      Geo Summary No          Component ID                System  Date  Status Limited    Ref    RFR Comment O1.G4.1.0006      1HP-190-12                      51A 04/24/08  CLR      N        N      N  UT-08-061 O1.G4.1.0009      1HP-190-16                      51A 04/24/08  CLR      N        N      N  UT-08-062 O1.G4.1.0010      1HP-190-13                      51A 04/24/08  CLR      N        N      N  UT-08-063 O1.G4.1.0011      1HP-279-4                        51A 04/16/08  CLR      N        N      N  UT-08-038 O1.G4.1.0012      1HP-279-3                        51A 04/16/08  CLR      N        Y      N  UT-08-040 Indication # 1-45o is a geometrical reflector from the weld root configuration.
O1.G4.1.0013      1HP-279-24                      51A 04/16/08  CLR      N        N      N  UT-08-041 O1.G4.1.0015      1HP-277-42C                      51A 04/21/08  CLR      N        N      N  UT-08-042 O1.G4.1.0016      1HP-277-43C                      51A 04/21/08  CLR      N        N      N  UT-08-043 O1.G4.1.0017      1HP-277-52                      51A 04/21/08  CLR      N        N      N  UT-08-044 O1.G4.1.0019      1HP-278-22C                      51A 04/21/08  CLR      N        N      N  UT-08-045 O1.G4.1.0020      1HP-278-23C                      51A 04/21/08  CLR      N        N      N  UT-08-046 O1.G4.1.0021      1HP-278-24                      51A 04/21/08  CLR      N        N      N  UT-08-047 O1.H2.1.0001      1-PHA-13                        50  04/17/08  CLR      N        N      N  PT-08-017 O1..H2.1.0002    1-PHA-14                        50  04/17/08  CLR      N        N      N  PT-08-018 Printed 7/17/2008 12:59:34 PM Ick8302 v. 01/01/08                              SDQA Cat "C"                    Oconee 1 7/17/2008 12:58:01 PM                          Page 24 of 26
 
0                                        Insp    Insp  Insp      Geo 0
Summary No          Component ID                System  Date  Status Limited    Ref    RFR Comment O1..H2.1.0003    1-PHA-15                        50  04/17/08  CLR    N        N      N  PT-08-019 01.H2.1.0010      1-PIB2-12                        50  04/19/08  CLR    N        N      N  PT-08-031 O1..H4.1.0008    1-03-0-551-R7                    03  04/22/08  CLR    N        N      N  MT-08-014 Note: A 10 inch portion of the examination surface was not accessible without removal of support members.
03  04/18/08  REC    N        N      N  VT-08-113 The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service.
O1..H4.1.0009    1-03-0-551-R11                  03  04/15/08  REC    N        N      N  VT-08-035 The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service.
O1.H4.1.0014      1-03-0-551--H60                  03  04/20/08  REC    N        N      N  VT-68-107 The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service.
O1.H4.1.0015      1-03-401B-H4171                  03  04/22/08  CLR    N        N      N  MT-08-015 03  04/20/08  REC    N        N      N  VT-08-108 The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service.
O1.H4.1.0016      1-03-0-551-R12                  03  04/23/08 CLR      N        N      N  MT-08-018 03  04/24/08 REC      N        N      N  VT-08-114 The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service.
Printed 7/17/2008 12:59:34 PM Ick8302 v. 01/01/08                            SDQA Cat "C"                  Oconee 1 7/17/2008 12:58:01 PM                        Page 25 of 26
 
Insp    Insp  Insp      Geo Summary No          Component ID                System  Date  Status Limited    Ref    RFR Comment O1.H4.1.0017      1-03-0-551-R13                  03  04/20/08  CLR    N          N      N  VT-08-081 O1..H4.1.0018    1-03-0-551--H59                  03  04/22/08  CLR    N          N      N  MT-08-016 03  04/20/08 REC      N          N      N  VT-08-109 The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service.
Ol.H4.1.0019      1-03-0-551-H58                  03  04/22/08 CLR      N          N      N  MT-08-017 03  04/24/08 CLR      N          N      N  VT-08-115 Printed 7/17/2008 12:59:34 PM Ick8302 v. 01/01/08                              SDQA Cat "C"                  Oconee 1 7/17/2008 12:58:01 PM                        Page 26 of 26
 
5.0    Owner's Report for Repairand Replacement Activities As required by the applicable code, records of Class 1 and Class 2 Repair and Replacement work is included on NIS-2 forms in this section.
Due to station processing and approval time frames, three categories of repair and replacement documentation exist for: 1) work performed during a prior refueling cycle; 2) work performed during the current refueling cycle; and 3) work completed but documentation not yet reviewed and approved.
There were 16 NIS-2 forms for work orders in Category 1 repair and replacement documentation for this reporting period. Work Orders 01678090-01, 01678089-21, 01678088-21, 01681624-22, 01681624-01, 01681624-02, 01681624-03, 01681624-04, 01681624-05, 01681624-07, 01681624-23, 01681624-25, 01681624-26, 01681624-27; 01681624-28, and 1678290 had work completed prior to 12-15-2006 and copies of the NIS-2 forms are included in this report. PIP 0-07-01152, PIP 0-07-01357, PIP 0-07-01656 and PIP 0-08-02675 were written to document the late submittal for the NIS-2 forms.
Category 2 had 36 Class 1 & 2 NIS-2 forms for work orders completed during this reporting period and there were 24 Class 3 NIS-2 forms for work orders completed during this reporting period. Copies of the NIS-2 forms are included in this section of the report.
There were no Category 3 items during this reporting period.
The individual work order documents and manufacturers' data reports are on file at Oconee Nuclear Station.
5.1    Class 1 and 2 Preservice Examinations There are no Preservice Inspection (PSI) Examinations on ISI Class 1 and ISI Class 2 items to report during this report period.
EOC 24 Refueling Outage Report                                                  Page 1 of 1 Oconee Unit .1                                                                  Revision 0 Section 5                                                                      July 17, 2008
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number                Sheet 1678088-o0i,-02,-2l,-31,-32, -37        I of A
: 1. Owner                                              2. Plant                                                      Unit Duke Power Company                                  Oconee Nuclear Station                                    ONS - 1 526 South Church Street                            7800 Rochester Hwy                                  Date Charlotte, NC 28201-1006                            Seneca, SC 29672                                        11/3/2006
: 3. Work Performed by                                                              Type Code Symbol Stamp Not Applicable Duke Power Company                                                  Authorization Number 526 South Church Street                                                                  Not Applicable Charlotte, NC 28201-1006                                              Expiration Date Not Applicable
: 4. Identification of System, ASME Class LPSW, ASME Class 2 5.
(a) Applicable Construction Code:            USAS B3 1.7          19    69  Edition,        No      Addenda,      No        Code Case (b) Applicable Edition Section XI Utilized For R/R Activity      19    98  Edition,      2000    Addenda.
(c) Applicable Section X1 Code Case(s)        None
: 6. Identification of Components Name of            Name of          Manufacturer        National            Other            Year    Corrected,        ASME Component          Manufacturer      Serial Number        Board No.      Identification        Built    Removed,          Code or Installed    Stamped (Yes / No) tube bundle, a R    CC                  Aerofin            None              None          "part" of S/N        1994      Removed          YES RB3CU Coil # 1                                                                    940305
    @ IC                    Aerofin            060916            2095          Tube bundle          2006      Installed        YES RBCU Coil # I 0    IC                                                                      tube bundle, a RBCU Coil #2                Aerofin            None              None          "part" of S/N        1994      Removed          YES
___940306
  @        C                Aerofin            060917            2096          Tube bundle          2006      Installed RBCU Coil # 2                                                                                                                  YES o0        iC C                Aerofin tube bundle, a None              None          "part" of S/N        1994      Removed          YES R13CU Coil #3                                                                      940302
  @C IC                      Aerofin.          06091.8            2097          Tube bundle          2006 RB3CU Coil # 3                                                                                                Installed        YES oR    IC C                Aerofin tube bundle, a None              None          "part" of S/N        1994      Removed          YES RBCU Coil # 4                                                                      940304        1        1                1
  §      IC RBCUAerofin RBCUCoilfi                                060919            2098          Tube bundle        2006        Installed 0      94                -
YES 00
: 7. Description of Work
- Planned replacement of the IC RBCU Coil tube bundles required removal/reinstallation of the cooler waterbox. This involved disassembling the Low Pressure Service Water (LPSW) piping to the coils. The 5/8-inch & 3/4-inch diameter LPSW piping bolting material for the piping-to-coil waterbox flanges required replacement due to surface degradation.
- All 4 of the IC RBCU coil tube bundles were replaced with new bundles due to extensive tube degradation.
: 8. Test Conducted D] Hydrostatic    0I'lPneumatic    0  Nominal Operating Pressure    E Exempt        [  Other Pressure                PSI              Test Temperature                    OF
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI ork Order Number              Sheet IW c 1678088                      2 of 3
: 1. Owner                                              2. Plant                                                    Unit Duke Power Company                                      Oconee Nuclear Station                                ONS - 1 526 South Church Street                                7800 Rochester Hwy                              Date Charlotte, NC 28201-1006                                Seneca, SC 29672                                      11/3/2006 3.. Work Performed by                                                            Type Code Symbol Stamp Not Applicable Duke Power Company                                                      Authorization Number 526 South Church Street                                                                    Not Applicable Charlotte, NC 28201-1006                                                Expiration Date Not Applicable
: 4. Identification of System, ASME Class LPSW, ASME Class 2 5.
(a) Applicable Construction Code:          USAS B31.7            19  69    Edition,      No      Addenda,      No      Code Case (b) Applicable Edition Section XI Utilized For R/R Activity        19  98    Edition,      2000      Addenda.
(c) Applicable Section X1 Code Case(s)        None
: 6. Identification of Components Name of            Name of          Manufacturer          National            Other            Year    Corrected,          ASME Component          Manufacturer      Serial Number        Board No.      Identification        Built    Removed,            Code or Installed      Stamped (Yes I No)
O    iC                              940305,940306,      537,538, 534, RBCU coils              Aerofin        940302,940304            536                              1994      Corrected          YES (all 4)                                940302, 940304          536 4-                  4                    4              4-                    4      .
* I S                    S              S                    S-        S                *-
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number                    Sheet 0                                                                                                    1678088                  3 of 3
: 9. Remarks (Applicable Manufacturer's Data Reports to be attached) 0 IC RBCU Coils # 1, 2, 3 & 4 had the tube bundles removed (due to extensive tube degradation) and replaced with new tube bundles. The waterboxes to the coils were not replaced, only the tube bundles. The waterboxes from the 4 old coils were reused.
Note that the waterbox is the subcomponent of the entire coil assembly that has the N-stamp nameplate attached to it.
0  IC RBCU Coils # 1,2, 3 & 4 - new tube bundles were installed. The tube bundle is a subcomponent of a RBCU coil. The coils are N-stamped components. (Form N-I's attached). Thewaterboxes to the coils were not replaced, only the tube bundles (NPT stamped parts, Form N-2's attached). The waterboxes from the 4 old coils were reused and were bolted up to the new bundles.
  § Replaced 5/8-inch diameter nuts (SA194 Gr 2H) and studs (SA193 B7 threaded rod) on the IC RBCU Coil waterbox-to-LPSW piping flanges. (Cat ID# 293556, UTC # 0001092855, and Cat ID# 297412, UTC #0001821109).                    Replaced 3/4-inch diameter nuts (SA 194 Gr 2H) and studs (SA193 B7 threaded rod) on the IC RBCU LPSW piping flanges. (Cat ID# 131796, UTC #
0001092163 and Cat ID# 297413, UTC # 0001092854.
0 AN CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section X1.
Type Code Symbol Stamp                                                      Not Applicable Certificate of Authorization Numb r                        Not Applicable          Expiration Date              Not Applicable Signed**                              /*    /,_              ejQilneer-          Date                1/3 10(
Owner or Owner's Designee, Title                              __
CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of ,                        ,              and employed by                      HSB CT of                                        Hartford, Connecticut                          have inspected the components described in this Owner's Report during the period                  lo-,16 - 0              to        z- Z 7- o )                  , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
_____________________________                              Commissions      /    '    ,,§Q,4  c._
                          ""in-spector's Signature                                    National Board, State, Province, and Endorsements Date      *-        7-o7
 
.,-    '.p,
(*Z~
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section X1 Work Order Number 1678089-o1 ,-02,-2 1,-31 ,-'36  I Sheet I of  AW
: 1. Owner                                                2. Plant                                                        Unit Duke Power Company                                  Oconee Nuclear Station                                      ONS - 1 526 South Church Street                              7800 Rochester Hwy                                  Date Charlotte, NC 28201-1006                              Seneca, SC 29672                                          10/30/2006
: 3. Work Performed by                                                                Type Code Symbol Stamp Not Applicable Duke Power Company                                                    Authorization Number 526 South Church Street                                                                  Not Applicable Charlotte, NC 28201-1006                                              Expiration Date Not Applicable
: 4. Identification of System, ASME Class LPSW, ASME Class 2 5.
(a) Applicable Construction Code:            USAS B31.7            19  69    Edition,        No    Addenda,          No      Code Case (b) Applicable Edition Section Xl Utilized For R/R Activity        19  98    Edition,      2000    Addenda.
(c) Applicable Section X1 Code Case(s)          None
: 6. Identification of Components Name of            Name of        Manufacturer        National              Other        Year        Corrected,        ASME Component            Manufacturer      Serial Number      Board No.        Identification      Built      Removed,          Code or Installed      Stamped (Yes / No) o        1B                                                                      tube bundle, a Aerofin            None            None            "part" of S/N      1994        Removed          YES RBCU Coil #
RBCU Coil___    #                                                                    940307
    @        lB                  Aerofin            060912            2091          Tube bundle        2006          Installed        YES RBCU Coil # I O IB                                                                            tube bundle, a RBCU Coil #2                  Aerofin            None            None            "part" of S/N      1994        Removed          YES RBCU__Coil__#      2940303 C Coi                Aerofin            060913            2092          Tube bundle        2006 RBCU Coil # 2.                                                                                                    Installed        YES 0          l1B                                                                    tube bundle, a RBCU Coil # 3                Aerofin            None            None            "part" of S/N      1994        Removed          YES RBCU__Coil___3_                                              940309 C Cl3                Aerofin            060914            2093          Tube bundle        2006 RBCU Coil # 3                                                                                                      Installed        YES O IB                                                                            tube bundle, a R1CU Coil #4                  Aerofin            None            None            "part" of S/N      1994        Removed          YES RB1UCoi__#                                                                    1      940310        1_      1_1 R          Coi              Aerofin            060915            2094            Tube bundle        2006 RB3CU Coil # 4111                                                                                                  Installed        YES 1
: 7.      Description of Work
    - Planned replacement of the 1B RBCU Coil tube bundles required removal/reinstallation of the cooler waterbox. This involved disassembling the Low Pressure Service Water (LPSW) piping to the coils. The 5/8Zinch & 3/4-inch diameter LPSW piping bolting material for the piping-to-coil waterbox flanges required replacement due to surface degradation.
    - All 4 of the lB RBCU coil tube bundles were replaced with new bundles due to extensive tube degradation.
: 8. Test Conducted II  Hydrostatic    []  Pneumatic    0  Nominal Operating Pressure    Eli Exempt          Other Pressure                PSI              Test Temperature                    OF
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI 9  --
Work Order Number              Sheet 1678089                    2 of 3
: 1. Owner                                              2. Plant                                                    Unit Duke Power Company                                      Oconee Nuclear Station                                ONS - 1 526 South Church Street                                7800 Rochester Hwy                              Date Charlotte, NC 28201-1006                                Seneca, SC 29672                                    10/30/2006
: 3. Work Performed by                                                              Type Code Symbol Stamp Not Applicable Duke Power Company                                                      Authorization Number 526 South Church Street                                                                  Not Applicable Charlotte, NC 28201-1006                                                Expiration Date Not Applicable
: 4. Identification of System, ASME Class LPSW, ASME Class 2 5.
(a) Applicable Construction Code:            USAS B31.7            19  69    Edition,      No      Addenda,  I No        Code Case (b) Applicable Edition Section XI Utilized For R/R Activity        19  98    Edition,      2000    Addenda.
(c) Applicable Section XI Code Case(s)        None
: 6. Identification of Components Name of          Name of            Manufacturer        National            Other          Year    Corrected,        ASME Component          Manufacturer      Serial Number        Board No.      Identification      Built    Removed,            Code or Installed      Stamped (Yes I No) 0 lB                                  940307,940303,      539,535,541,1 RBCU coils              Aerofin        940309, 940310          542                              1994      Corrected        YES (all 4)                                940309, 9403_0          542
                  .1.                J.                  4              4.                  4        4                  4
__I__I__I__I                                                                                    I~]
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section Xl Work Order    1678089 Number          I Sheet3 of 3
: 9. Remarks (Applicable Manufacturer's Data Reports to be attached) o 1B RBCU Coils # 1, 2, 3 & 4 had the tube bundles removed (due to extensive tube degradation) and replaced with new tube bundles. The waterboxes to the coils were not replaced, only the tube bundles. The waterboxes from the 4 old coils were reused.
Note that the waterbox is the subcomponent of the entire coil assembly that has the N-stamp nameplate attached to it.
0 lB RBCU Coils # I, 2, 3 & 4 - new tube bundles (Catalog ID # 597036) were installed. The tube bundle is a subcomponent of a RBCU coil. The coils are N-stamped components. (Form N-l's attached). The waterboxes to the coils were not replaced, only the tube bundles (NPT stamped parts, Form N-2's attached). The waterboxes from the 4 old coils were reused and were bolted up to the new bundles.
O Replaced 5/8-inch diameter nuts (SA194 Gr 2H) and studs (SA193 B7 threaded rod) on the lB RBCU Coil waterbox-to-LPSW piping flanges. (Stock Code # 293556, UTC 4's 0001088212 and 0001092855, and Stock Code # 297412, UTC # 0001821577).
Replaced 3/4-inch diamneter nuts (SA 194 Gr 2H) and studs (SA 193 B7 threaded rod) on the 1B RBCU LPSW piping flanges.
(Stock Code 131796, UTC # 0001092163 and Stock Code 297413, UTC # 0001092854.
0 0
0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.
Type Code Symbol Stamp                                                          Not Applicable Certificate of Authorization Number                          Not Applicable            Expiration Date              Not Applicable
                ",*/          Ow"ner or Ovn~er~s Designee,r~itle                      Dae          '/      /    (
Signed-                    ,                                  enineer I'/31/0"        Date CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of A, e7 .V                                      and employed by                    HSB CT of                                      Hartford, Connecticut                              have inspected the components described in this Owner's Report during the period                        /o - /Z -            to        Z_- e ý7-0 7                  , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
___________________________                                    Commissions  ,./        '/',/.)/*,4,C e--'rnspector's Signature                                            National Board, State, Province, and Endorsements      -:
Date                  ___7
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section X1 Shee t 1of33*0 I 1678090-o1,-02,-l Work Order Number2,-13,-22, -36
: 1. Owner                                              2. Plant                                                      Unit Duke Power Company                                  Oconee Nuclear Station                                    ONS - 1 526 South Church Street                              7800 Rochester Hwy                                  Date Charlotte, NC 28201-1006                            Seneca, SC 29672                                        11/6/2006
: 3. Work Performed by                                                              Type Code Symbol Stamp Not Applicable Duke Power Company                                                    Authorization Number 526 South Church Street                                                                  Not Applicable Charlotte, NC 28201-1006                                              Expiration Date Not Applicable
: 4. Identification of System, ASME Class LPSW, ASME Class 2 5.
(a) Applicable Construction Code:          USAS B31.7            19    69  Edition,        No      Addenda,      No      Code Case (b) Applicable Edition Section XI Utilized For R/R Activity      19    98  Edition,      2000    Addenda.
(c) Applicable Section Xl Code Case(s)        None
: 6. Identification of Components Name of              Name of        Manufacturer        National            Other          Year      Corrected,        ASME Component            Manufacturer      Serial Number      Board No.        Identification      Built    Removed,          Code or Installed      Stamped (Yes / No) a tube bundle, C      Il              Aerofin            None            None            "part" of S/N      1994      Removed            YES RBCU Coil # 1 940311 C      Il              Aerofin            060908            2087            Tube bundle        2006 RBCU Coil # I                                                                                                    Installed        YES O IA                                                                          tube bundle, a R        Il              Aerofin              None            None            "part" of S/N      1994      Removed            YES RBCU Coil # 2 940312
*) C IA Il              Aerofin            060909            2088            Tube bundle        2006 RBCU Coil # 2                                                                                                  Installed        YES o        IA                                                                    tube bundle, a C      Il              Aerofin              None            None            "part" of S/N      1994      Removed            YES RBCU Coil # 3 940301
*R    IA Il              Aerofin            060910            2089          Tube bundle        2006 RB3CU Coil #3                                                                                                  Installed        YES o      IA                                                                      tube bundle, a R        Il              Aerofin              None            None            "part" of S/N      1994      Removed            YES RBCU Coil # 4        1                  1                  11                      940308        1        1                1
§      IA C Il                  Aerofin            060911            2090            Tube bundle RBCU Coil # 4                                                                                      2006        Installed        YES 1111
: 7. Description of Work
- Planned replacement of the I A RBCU Coil tube bundles required removal/reinstallation of the cooler waterbox. This involved disassembling the Low Pressure Service Water (LPSW) piping to the coils. The 5/8-inch & 3/4-inch diameter LPSW piping bolting material for the piping-to-coil waterbox flanges required replacement due to surface degradation.
- All 4 of the IA RBCU coil tube bundles were replaced with new bundles due to extensive tube degradation.
: 8. Test Conducted El Hydrostatic    E Pneumatic      H Nominal Operating Pressure        - Exempt      E Other Pressure                PSI              Test Temperature                  OF
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI U
Work Order Number 0                                                                                                1678090 Sheet2of2 o3c38
: 1. Owner                                              2. Plant                                                        Unit Duke Power Company                                        Oconee Nuclear Station                                  ONS - 1 526 South Church Street                                  7800 Rochester Hwy                                Date Charlotte, NC 28201-1006                                  Seneca, SC 29672                                      11/6/2006
: 3. Work Performed by                                                                Type Code Symbol Stamp Not Applicable Duke Power Company                                                        Authorization Number 526 South Church Street                                                                      Not Applicable Charlotte, NC 28201-1006                                                  Expiration Date Not Applicable
: 4. Identification of System, ASME Class LPSW, ASME Class 2 5.
(a) Applicable Construction Code:            USAS B31.7            19  69    Edition,.      No      Addenda,    No      Code Case (b) Applicable Edition Section X1 Utilized For R/R Activity          19  98    Edition,      2000      Addenda.
(c) Applicable Section XI Code Case(s)          None
: 6. Identification of Components Name of          Name of          Manufacturer          National            Other            Year    Corrected,          ASME Component          Manufacturer        Serial Number        Board No.        Identification        Built    Removed,              Code or Installed        Stamped (Yes / No)
-      -              4                  4                    4                4-                    4.      4.                4.
    @    IA 940311,940312,      543,544,533, RBCU coils              Aerofin                                                                      1994      Corrected          YES 940301,940308            540 (all 4)
                    -t                  4                    4                4.-                    1-      4.                4.
                                        +                    4.                4                      4.      4                  +
4                  .4.                  4.                4                      4        4                  +
                      &                  i.                  ,I.                                                                  ,I.
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number                  Sheet 1678090                  3 ofS
: 9. Remarks (Applicable Manufacturer's Data Reports to be attached) o 1A RBCU Coils # 1,2, 3 & 4 had the tube bundles removed (due to extensive tube degradation) and replaced with new tube bundles. The waterboxes to the coils were not replaced, only the tube bundles. The waterboxes from the 4 old coils were reused.
Note that the waterbox is the subcomponent of the entire coil assembly that has the N-stamp nameplate attached to it.
@ IA RBCU Coils # I, 2, 3 & 4 - new tube bundles were installed. The tube bundle is a subcomponent of a RBCU coil. The coils are N-stamped components. (Form N-I's attached). The waterboxes to the coils were not replaced, only the tube bundles (NPT stamped parts, Form N-2's attached). The waterboxes from the 4 old coils were reused and were bolted up to the new bundles.
0 Replaced 5/8-inch diameter nuts (SA194 Gr 2H) and studs (SA193 B7 threaded rod) on the IA RBCU Coil waterbox-to-LPSW piping flanges. (Cat ID# 293556, UTC# 0001092855, and Cat ID# 297412, UTC# 0001821109, 000109200, 0001821577).
Replaced 3/4-inch diameter nuts (SA194 Gr2H) and studs (SA193 B7 threaded rod) on the IA RBCU LPSW piping flanges. (Cat ID# 131796, UTC # 0001092163 and Cat ID# 297413, UTC # 0001092854.
0 0
0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.
Type Code Symbol Stamp                                                  Not Applicable Certificate of Authorization Number                  Not Applicable            Expiration Date              Not Applicable Signed          c._*/e494//"L                : eqlr'neer                      Date            / ;/0cI C            Owner or Owner's Designbee, Title'v CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of tlox7-1,,                              and employed by                    HSB CT of                                  Hartford, Connecticut                              have inspected the components described in this Owner's Report during the period              / 0 -  - 0<=,          to        e- Z ?- 0 7                  , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or nnected with this inspection.
S
________________________
ector's Signature Commissions  __,,______//,_,/_.__,,____.
National Board, State, Province, and Endorsements Date    __    _    _    _    _      _
 
Form NIS-2 Owner's Report for Repair/Replacement Activities As required by the provisions of the ASME Code Section XI Work Order Numbe                Sheet 01681624 - 22                        Pagel of 2
: 1. Owner        Duke Power Company                                            2.Plant    Oconee Nuclear Station                                  unit 526 South Church Street                                                  7800 Rochestor Hwy Date Charlotte, NC 28201-1006                                                Seneca, SC 28672                                                    11/15/2006
: 3. Work Performed By                                                                                                    Type Code Symbol Stamp I                    Not N Applicable Duke Power Company Authorization Number 526 South Church Street                                                                                                          Not Applicable Charlotte, NC 28201-1006                                                                                Expiration Date          Not Applicable
: 4. Identification of Systems, ASME Class Vents - Reactor Bldg. Components ,            ASME Class 1 (a) Applicable Construction Cod    USAS B31.7                1969:  Edition,  No    Addenda 5  Code Case  2 (b) Applicable Edition Section XI Utilized For R/R Activity  1998:  Edition,  N-o    Addenda (c) Applicable Section XI Codes Cases(s)          None
: 6. Identificatiorl of Coimponents Name of Component                        Manufactur:          Manufacture        National        Other            Year      Corrected,      ASME Code Serial Number      Board No    identification      Built    Removed or        Stamped Installed        (Yes/No)
(2) 50-0-479A-H12, Size 2-1/2 X 5                  Grinnell              18794                UNK          N/A                UNK      Removed          No Hydraulic Snubber Cylinder (New Miller)
(1) 50-0-479A-H12, Size 2-1/2 X 5                  Anvil                  36541                UNK          UTC                UNK      Installed        No Hydraulic Snubber Cylinder (Config.                                                                          1823529 A)
: 7. Description of Work Rebuilt existing snubber cylinder with a Config. A pressurized cylinder.
: 8. Test Conducted E]    Hydrostatic            D    Pnuematic              L] Nominal Operating Pressure          ED  Excempt          W      Other      Visual Pressure                        PSI                                                Test Temperature                        Deg. F
 
Form NIS-2 Owner's Report for Repair/Replacement Activities As required by the provisions of the ASME Code Section XI                                                          Work Order Numbe                  Sheet 01681624      -  22            Page2of2
: 7. Remarks (Applicable Manufactuerr's Data Reports to be attached)
(2) Replaced existing snubber cylinder with Config. A type.
CERTIFICATION OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI .              .-
Type Code Symbol Stamp                                                              Not Applicable Certificate of Autherization Number                          Not Applicable                        Expiration Date                  Not Applicable Signed      _      _          _ _      _    ___      _    _      _      _    _    _      _                        ___/_-_____
_Date Owner or Owner's Designee, Title CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and State or province of Al/oer.A -,, ., oe.a,*          0            and employed by                            HSB CT of                              Hartford, Connecticut                                  have inspected the components described in the Owner's Report during the period                        a        o2      to      Z - a 7- o 7                        , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.
By signing this certificate neither the inspector nor his employer make any warrenty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind rising from or connected with this inspection.
                    &#xfd;
:e&#xfd;                  ~        Commision(s)        AI inspector's Signature                                                  National Board, State, Province, and Endorsements Date            27-      0 -7
 
Form NIS-2 Owner's Report for Repair/Replacement Activities As required by the provisions of the ASME Code Section XI Work Order Numbe              Sheet 01681624 - 01                        Pagel  of 2
: 1. Owner        -Duke Power Company                                        2. Plant    Oconee Nuclear Station                                Unit 526 South Church Street                                                7800 Rochestor Hwy Charlotte, NC 28201-1006                                                Seneca, SC 28672                                                    11/15/2006
: 3. Work Performed By                                                                                                        I Symbol Stamp Type Code                Not Applicable Duke Power Company                                                                                    I 526 South Church Street                                                                                  i                      Not Applicable Charlotte, NC 28201-1006                                                                                Expiration Date          Not Applicable
: 4. Identification of Systems, ASME Class Main Steam    ,  ASME Class 2 (a) Applicable Construction Cod USAS B31.7                  1967: Edition,  No    Addenda No    Code Case (b) Applicable Edition Section XI Utilized For R/R Activity  1998: Edition,  2000    Addenda (c) Applicable Section XICodes Cases(s)            None
: 6. Identification of Coimponents Name of Component                        Manufactur:          Manufacture            National      Other            Year    Corrected,      ASME Code Serial Number        Board No    identification      Built  Removed or          Stamped Installed        (Yes/No)
(2) 1-01A-2-1-0-401A-SR2204, Size                    Grinnell            00149                  UNK        N/A                UNK      Removed          No 2-1/2 X 10 Hydraulic Snubber (1) 1-01A-2-1-0-401A-SR2204, Size                    Anvil                35418                  UNK        UTC                UNK      Installed        No 2-1/2 X 10 Hydraulic Snubber                                                                                  1045666
: 7. Description of Work Replaced existing hydraulic snubber with a new , Config. A pressurized cylinder snubber.
: 8. Test Conducted FD    Hydrostatic            FD    Pnuematic                Nominal Operating Pressure
[]                                  ED  Excempt          V    Other      Visual Pressure                          PSI                                              Test Temperature                      Deg. F
 
"Form NIS72 Owner's Report for Repair/Replacement Activities As required by the provisions of the ASME Code Section XI                                                      Work Order Numbe                  Sheet 01681624    -  01              Page2of2
: 7. Remarks (Applicable Manufactuerr's Data Reports to be attached)
(2) Replaced entire snubber CERTIFICATION OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI Type Code Symbol Stamp                                                          Not Applicable Certificate of Autherization Number                            Not Applicable                  Expiration Date                  Not Applicable Signed                                                        6&deg;  ,  '                        Date          __//_._                            _
Owner or Owner's Designee, Title CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel 7
Inspectors and State or province of ,A-U0                "C7-W      U"4  ). and employed by                          HSB CT of                              Hartford, Connecticut                              have inspected the components described in the Owner's Report during the period                            e oe-      to      `-/        -o 2                  , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the inspector nor his employer make any warrenty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind rising from or connected with this inspection.
                                                ~ Commision(s)
Inspector's Signature                                              National Board, State, Province, and Endorsements Date        .            oZ
 
Form NIS-2 Owner's Report for Repair/Replacement Activities As required by the provisions of the ASME Code Section XI Work Order Numbe                Sheet 01681624 - 02                        Pagel of 2
: 1. owner        Duke Power Company                                        2. Plant    Oconee Nuclear Station                                    Unit 526 South Church Street                                                7800 Rochestor Hwy Date Charlotte, NC 28201-1006                                              Seneca, SC 28672                                                      11/15/2006
: 3. Work Performed By                                                                                                  Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street                                                                                                  i        Not Applicable Charlotte, NC 28201-1006 Expiration Date          Not Applicable
: 4. Identification of Systems, ASME Class Main Steam    ,    ASME Class 2 5.
(a) Applicable Construction Cod USAS B31.7,                1967: Edition,  No      Addenda No    Code Case (b) Applicable Edition Section XIUtilized For R/R Activity  1998: Edition,  2000    Addenda (c) Applicable Section XiCodes Cases(s)          None
: 6. Identification of Coimponents Name of Component                        Manufactur:        Manufacture            National      Other          Year      Corrected,      ASME Code Serial Number        Board No    identification      Built    Removed or        Stamped Installed        (Yes/No)
(3) 1-01A-0-550-R14, Bushing,                      Grinnell            N/A                    UNK          N/A                UNK      Removed          No cylinder rod (2) 1-01A-0-550-R14, Size 6 X 5                    Grinnell            22605                  UNK          N/A                UNK      Removed          No Hydraulic Snubber Cylinder (New Miller)
(4) 1-01A-0-550-R14, Bushing,                      Anvil                N/A                    UNK          N/A                UNK      Installed        No cylinder rod (1) 1-01A-0-550-R14, Size 6 X 5                    Anvil                36458                  UNK          UTC                UNK      Installed        No Hydraulic Snubber Cylinder (Config.                                                                          1821446 A)
: 7. Description of Work Rebuilt existing snubber cylinder with a Config. A pressurized cylinder.
: 8. Test Conducted FD    Hydrostatic          D    Pnuematic            [  Nominal Operating Pressure            []  Excempt        [      Other      Visual Pressure                        PSI                                                Test Temperature                        Deg. F
 
Form NIS-2 Owner's Report for Repair/Replacement Activities As required by the provisions of the ASME Code Section XI                                                          Work Order Numbe                Sheet 01681624      -  02            Pag;2of2
: 7. Remarks (Applicable Manufactuerr's Data Reports to be attached)
(2) Replaced existing snubber cylinder with Config. A type.
(3) Bushing was degraded CERTIFICATION OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl Type Code Symbol Stamp                                                              Not Applicable Certificate of Autherization Number                          Not Applicable                        Expiration Date                Not Applicable Signed                                              ____,          __          ___        __Date                iibi      /*
Owner or Owner's Designee, Title CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and State or province of A.A0,*-'t7j*ee,                      f4'    and employed by                          HSB CT of                              Hartford, Connecticut                                    have inspected the components described in the Owner's Report during the period                                              to    9*-. 7.0          7                , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the inspector nor his employer make any warrenty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind rising from or connected with this inspection.
                    ~~~~~~~~ommi sion(s)                                  ,jj,/_.//..4*                        .
Inspector's Signature                                                    National Board, State, Province, and Endorsements Date
 
Form NIS-2 Owner's Report for Repair/Replacement Activities As required by the provisions of the ASME Code Section Xl Work Order Numbe                Sheet 01681624 - 03                        Pagel of 2
: 1. owner        Duke Power Company                                            2. Plant    Oconee Nuclear Station                                unit 1
526 South Church Street                                                  7800 Rochestor Hwy Date Charlotte, NC 28201-1006                                                  Seneca, SC 28672                                                    11/15/2006
: 3. Work Performed By                                                                                                    Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street                                                                                                            Not Applicable Charlotte, NC 28201-1006                                                                                Expiration Date          Not Applicable
: 4. Identification of Systems, ASME Class Main Steam ,    ASME Class 2 5.
(a) Applicable Construction Cod USAS B31.7                  1967:  Edition,  No      Addenda No  Code Case (b) Applicable Edition Section XIUtilized For R/R Activity  1998:  Edition,  2000    Addenda (c) Applicable Section X1Codes Cases(s)          None
: 6. Identification of Coimponents Name of Component                        Manufactur:            Manufacture          National      Other            Year      Corrected,      ASME Code Serial Number        Board No    identification      Built    Removed or          Stamped Installed        (Yes/No)
(1) 1-01A-0-550-R15, Size 6 X 5                    Grinnell              22609                  UNK          N/A                UNK      Removed          No Hydraulic Snubber (2) 1-01A-0-550-R15, Size 6 X 5                    Anvil                  36331                  UNK          UTC                UNK      Installed        No Hydraulic Snubber                                                                                              1823723
: 7. Description of Work Replaced existing hydraulic snubber with a new , Config. A pressurized cylinder snubber.
: 8. Test Conducted D      Hydrostatic          D    Pnuematic              E] Nominal Operating Pressure          ED  Excempt          R]    Other    Visual Pressure                        PSI                                                Test Temperature                        Deg. F
 
Form NIS-2 Owner's 'Report for Repair/Replacement Activities As required by the provisions of the ASME Code Section XI 01681624 WokOrder Numbe      -03        Sheet Page 2of 2
: 7. Remarks (Applicable Manufactuerr's Data Reports to be attached)
(1) Replaced entire snubber CERTIFICATION OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl Type Code Symbol Stamp                                                          Not Applicable Certificate of Autherization Number                          Not Applicable                  Expiration Date                  Not Applicable Signed                                                                -h9 .
                                                                            ''A.,                    Date          _      ____-____
Owner or Owner's Designee, Title CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and State or province of A)otr-W                  -            and employed by                          HSB CT of                              Hartford, Connecticut                              have inspected the components described
      'in the Owner's Report during the period                57- e.;.                to        t'-o 7                          , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the inspector nor his employer make any warrenty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind rising from or connected with this inspection.
                                        ~          Commision(s)
Inspector's Signature                                              National Board, State, Province, and Endorsements Date                      ;,
 
Form NIS-2 Owner's Report for Repair/Replacement Activities As required by the provisions of the ASME Code Section XI Work Order Numbe                Sheet 01681624 - 04                        Pagel    of 2
: 1. Owner      Duke Power Company                                              2. Plant    Oconee Nuclear Station                                  Unit 526 South Church Street                                                    7800 Rochestor Hwy Date Charlotte, NC 28201-1006                                                    Seneca, SC 28672                                                    11/15/2006
: 3. Work Performed By                                                                                                    Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street                                                                                      i                      Not Applicable Charlotte, NC 28201-1006                                                                                  Expiration Date          Not Applicable
: 4. Identification of Systems, ASME Class Main Steam ,    ASME Class 2 5.
(a) Applicable Construction'Cod    USAS B31.7                1969:  Edition,  No      Addenda No  Code Case (b) Applicable Edition Section XI Utilized For R/R Activity  1998:  Edition, 5        Addenda (c) Applicable Section XI Codes Cases(s)          None                            3/S
: 6. Identification of Coimponents Name of Component                        Manufactur:            Manufacture          National      Other            Year      Corrected,      ASME Code Serial Number        Board No    identification      Built    Removed or        Stamped Installed        (Yes/No),,
(2) 1-01A-0-550-R2(B), Size 4 X 5                    Grinnell              16282                  UNK          N/A                UNK      Removed          No Hydraulic Snubber Cylinder (New Miller)
(1) 1-01A-0-550-R2(B), Size 4 X 5,                  Anvil                  36243                  UNK          UTC                UNK      Installed        No Hydraulic Snubber Cylinder (Config.                                                                            1086638 A)
: 7. Description of Work Rebuilt existing snubber cylinder with a Config. A pressurized cylinder.
: 8. Test Conducted FD    Hydrostatic            FD Pnuematic                E] Nominal Operating Pressure            ED  Excempt          k      Other    Visual Pressure                          PSI                                                Test Temperature                        Deg. F
 
Form NIS-2 Owner's Report for Repair/Replacement Activities As required by the provisions of the ASME Code Section XI.                                                          Work Order Numbe                Sheet 01681624 - 04                  Page2of2
: 7. Remarks (Applicable Manufactuerr's Data Reports to be attached)
(2) Replaced existing snubber cylinder with Config. A type.
CERTIFICATION OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI Type Code Symbol Stamp                                                                Not Applicable Certificate of Autherization Number                            Not Applicable                        Expiration Date                Not Applicable Signed      _      _      _    _    _    _      _      _      _      _    _        _      _Date                      ,  /,c Owner or Owner's Designe?, Title CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and State or province of Al,_7"4- Cf,.ol,.,,,                          and employed by                          HSB CT of                              Hartford, Connecticut                                  have inspected the components described in the Owner's Report during the period                      f=      -,,            to S3-/v-o 7                              , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.
By signing this certificate neither the inspector nor his employer make any warrenty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind rising from or connected with this inspection.
                                              ~    Commision(s)                //-OzA'4c.
Inspectors Signature                                                    National Board, State, Province, and Endorsements Date    J              7
 
Form NIS-2 Owner's Report for Repair/Replacement Activities As required by the provisions of the ASME Code Section XI Work Order Numbe                  Sheet 0
1V 01681624      - 05 Page 1 of 2
: 1. Owner        Duke Power Company                                          2. Plant    Oconee Nuclear Station                                  unit 526 South Church Street                                                  7800 Rochestor Hwy 7 Date
                  -Charlotte, NC 28201-1006                                                  Seneca, SC 28672                                                    11/15/2006
: 3. Work Performed By                                                                                                    Type Code Symbol Stamp I                    Not Applicable Duke Power Company Authorization Number 526 South Church Street                                                                                                            Not Applicable Charlotte, NC 28201-1006                                                                                Expiration Date          Not Applicable
: 4. Identification of Systems, ASME Class.
Main Steam    ,  ASME Class 2 5.
(a) Applicable Construction Cod    USAS B31.7              1969:  Edition,  No      Addenda No    Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 1998:  Edition,          Addenda A *c-(c) Applicable Section XI Codes Cases(s)          None                          31g,/"o 7
: 6. Identification of Coimponents Name of Component                        Manufactur:          Manufacture          National      Other            Year      Corrected,      ASME Code Serial Number        Board No    identification      Built    Removed or          Stamped Installed        (Yes/No)
(5) 1-01A-0-550-R9-2, Size 4 X 5                    Grinnell              33612                  UNK        N/A                UNK      Removed          No Hydraulic Snubber Cylinder (New Miller)
(2) 1-01A-0-550-R9-1, Size 4 X 5                    Grinnell              30203                  UNK        N/A                UNK      Removed          No Hydraulic Snubber Cylinder (New Miller)
(1) 3 bushings and cylinder rods                    Grinnell              N/A                    UNK                            UNK      Removed          No (4) 1-01A-0-550-R9-4, Size 4 X 5                    Grinnell              36538                  UNK        N/A                UNK      Removed          No Hydraulic Snubber Cylinder (New Miller)
(7) 1-01A-0-550-R9-2, Size 4 X 5                    Anvil                36535                  UNK        UTC                UNK      Installed        No Hydraulic Snubber Cylinder(Config.                                                                            1823526 A)
(3) 1-01A-0-550-R9-1, Size 4 X 5                    Anvil                36537                  UNK        UTC                UNK      Installed        No Hydraulic Snubber Cylinder (Config.                                                                          1823526 A)
(6) 3 bushings and cylinder rods                    Anvil                N/A                    UNK        N/A                UNK      Installed        No (8) 1-01A-0-550-R9-4, Size 4 X 5                    Anvil                36538                  UNk        UTC                UNK      Installed        No Hydraulic Snubber Cylinder (Config.                                                                          1823526 A)
: 7. Description of Work Rebuilt existing snubber cylinder with a Config. A pressurized cylinder.
: 8. Test Conducted D    Hydrostatic            D]  Pnuematic              [  NominalOperating Pressure            D  Excempt          [      Other      Visual Pressure                          PSI                                                Test Temperature                        Deg. F
 
Form NIS-2 Owner's Report for Repair/Replacement Activities As required by the provisions of the ASME Code Section X1                                                    Work Order Numbe                Sheet 01681624    -  05            , .Page2of2 7.Remarks (Applicable Manufactuerr's Data Reports to be attached)
(4) Replaced existing snubber cylinder with Config. A type.
(1) Bushing and cylinder rods were degraded (2) Replaced existing snubber cylinder with Config. A type.
(5) Replaced existing snubber cylinder with Config. A type.
J CERTIFICATION OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl Type Code Symbol Stamp                                                        Not Applicable Certificate of Autherization Number                          Not Applicable                    Expiration Date                Not Applicable Signed                                                J*______-_._,                          Date      _            M/ r,__/_-
Owner or Owner's Designee, Title CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and State or province of 1L'oz-.w.,YoeeczIAov&.                  and employed by                          HSB CT of                              Hartford, Connecticut                            have inspected the components described in the Owner's Report during the period                        Y-Z -o,-.        to      d-.-- -0?                        , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the inspector nor his employer make any warrenty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind rising from or connected with this inspection.
Inspector's Signature                                            National Board, State, Province, and Endorsements Date 3-*,y-.
 
Form NIS-22 Owner's Report for Repair/Replacement Activities As required by the provisions of the ASME Code Section XI Work Order Numbe                &#xfd;Sheet 016816241-        07                  Page 1 of 2
: 1. Owner        Duke Power Company                                          2. Plant    Oconee Nuclear Station                                    unit 526 South Church Street                                                  7800 Rochestor Hwy Date Charlotte, NC 28201-1006                                                  Seneca, SC 28672                                                        11/15/2006
: 3. Work Performed By                                                                                                      Type Code Symbol Stamp I                    Not Applicable Duke Power Company Authorization Number 526 South Church Street                                                                                                              Not Applicable Charlotte, NC 28201-1006                                                                                  Expiration Date
______________________________________________________________________Not___ApNot                                    ippliabl
: 4. Identification of Systems, ASME Class
                                                    ;ure Injection - High Pressure Portion        ,  ASME Class 1 5.
(a) Applicable Construction Cod    USAS B31.7              1969:  Edition,  No      Addenda No    Code Case (b) Applicable Edition Section XI Utilized For RIR Activity 1998:  Edition, .    '    Addenda (c) Applicable Section Xl Codes Cases(s)          Non.e                      310    .W
: 6. Identification of Coimponents Name of Component                        Manufactur:          Manufacture            National      Other            Year      Corrected,        ASME Code Serial Number          Board No    identification      Built    Removed or            Stamped Installed          (Yes/No)
(1) 1-51A-0-479A-H17A, Size 2-1/2                    Grinnell              30220                    UNK          N/A                LUNK      Removed          No X 5 Hydraulic Snubber (2) 1-51A-0-479A-H17A, Size 2-1/2                  Anvil                36153                    UNK          UTC                UNK      Installed        No X 5 Hydraulic Snubber                                                                                            1082294
: 7. Description of Work Replaced existing hydraulic snubber with a new, Config. A pressurized cylinder snubber.
: 8. Test Conducted D      Hydrostatic              D  Pnuematic              D  Nominal Operating Pressure              DJ Excempt          k      Other      Visual Pressure                          PSI                                                  Test Temperature                        Deg. F
 
'Form NIS-2 Owner's Report for Repair/Replacement Activities As required by the provisions of the ASME Code Section XI                                                      Wk Order Numbe                    Sheet 01681624          07              Page 2 of 2
: 7. Remarks (Applicable Manufactuerr's Data Reports to be attached)
(1) Replaced entire snubber CERTIFICATION OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI Type Code Symbol Stamp                                                            Not Applicable Certificate of Autierization Number                            Not Applicable                    Expiration Date                  Not Applicable Signed      _fgool..*,                        &#xfd;      ,A      ,                                  Date          &_          _    _    _  _    _  _
Owner or Owner's Designee, Title CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and State or province of ,4/o,*-* i*oe,o/A                          and employed by                          HSB CT of                              Hartford, Connecticut                                have inspected the components described in the Owner's Report during the period                      3-/ r/-0            to    3 -/*-'*?                          , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the inspector nor his employer make any warrenty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind rising from or connected with this inspection.
SCommision(s)            1      /_1 /  -Vx/A',-W&        .
Inspectors Signature                                                National Board, State, Province, and Endorsements Date IA
 
Form NIS-2 Owner's Report for Repair/Replacement Activities As required by the provisions of the ASME Code Section XI                                                        Work Order Numbe                  Sheet 01681624 - 23                        Pagel of 2
: 1. Owner      , Duke Power Company                                          2. Plant    Oconee Nuclear Station                                  Unit 526 South Church Street                                                  7800 Rochestor Hwy Date Charlotte, NC 28201-1006                                                Seneca, SC 28672                                                      11/15/2006
: 3. Work Performed By                                                                                                    Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street                                                                                                            Not Applicable Charlotte, NC 28201-1006                                                                                Expiration Date          Not Applicable
: 4. Identification of Systems, ASME Class Reactor Coolant    ,  ASME Class  1 5.
(a) Applicable Construction Cod USAS B31.7                  1967:  Edition,  No      Addenda No    Code Case (b) Applicable Edition Section XI Utilized For R/R Activity  1998:  Edition,  2000    Addenda (c) Applicable Section XiCodes Cases(s)            Non._e
: 6. Identification of Coimponents Name of Component                        Manufactur:            Manufacture          National      Other            Year      Corrected,      ASME Code Serial Number          Board No    identification      Built    Removed or        Stamped Installed        (Yes/No)
(1) 50-0-480A-H10, Size 2-1/2 X 5                    Grinnell              18791                  UNK        N/A                UNK      Removed          No Hydraulic Snubber (2) 50-0-480A-H1O, Size 2-1/2 X 5                    Anvil                36429                    UNK        UTC                UNK      Installed        No Hydraulic Snubber                                                                                              1821556
: 7. Description of Work Replaced existing hydraulic snubber with a new, Config. A pressurized cylinder snubber.
: 8. Test Conducted D]    Hydrostatic            FD    Pnuematic              D] Nominal Operating Pressure            ED  Excempt          W]    Other      Visual Pressure                          PSI                                                Test Temperature                        Deg. F X-
 
Form NIS-2 Owner's Report for Repair/Replacement Activities As required by the provisions of the ASME Code Section XI                                                    Work Order Numbe                Sheet 01681624    -  23              Page2of2
: 7. Remarks (Applicable Manufactuerr's DataReports to be attached)
(1) Replaced entire snubber CERTIFICATION OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI Type Code Symbol Stamp                                                          Not Applicable Certificate of Autherization Number                          Not Applicable                    Expiration Date                Not Applicable Signed        ______                      ________                                D          Date          _    _    _    _    _  _    _ _
Owner or Owner's Designee Title CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and State or province of ,2ober/,              *,'a,-,'A        and employed by                          HSB CT of                              Hartford, Connecticut                              have inspected the components described in the Owner's Report during the period                                          to      5/,      '-o &#xfd;0                  ,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.
By signing this certificate neither the inspector nor his employer make any warrenty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind rising from or connected with this inspection.
                    ~~~~~~~~Commision(s)                                  ,*J*/*J*      '    UOj*_
Inspector's Signature                                              National Board, State, Province, and Endorsements Date          5 -, ,- o
 
Form NIS-2 Owner's Report for Repair/Replacement Activities As required by the provisions of the ASME Code Section XI                                                        Work Order Numbe                Sheet 01681624 - 25                        Pagel of 2 wi                                                                                                                                                  p 1.owner        Duke Power Company                                          2. Plant    Oconee Nuclear Station                                  Unit 526 South Church Street                                                  7800 Rochestor Hwy Date Charlotte, NC 28201-1006                                                  Seneca, SC 28672                                                    11/15/2006
: 3. Work Performed By                                                                                                    Type Code Symbol Stamp I                    Not Applicable N
Duke Power Company Authorization Number 526 South Church Street                                                                                                            Not Applicable Charlotte, NC 28201-1006                                                                                  Expiration Date          Not Applicable
: 4. Identification of Systems, ASME Class
                                                      ;ure Injection - High Pressure Portion        ,  ASME Class 2 5.
(a) Applicable Construction Cod    USAS B31.7              1967:  Edition,  No      Addenda No    Code Case (b) Applicable Edition Section Xi Utilized For RFRActivity  1998:  Edition,  2000    Addenda (c) Applicable Section XI Codes Cases(s)          None
: 6. Identification of Coimponents Name of Component                        Manufactur:          Manufacture          National      Other            Year      Corrected,      ASME Code Serial Number        Board No    identification      Built    Removed or          Stamped Installed        (Yes/No)
(2) 53A-0-479A-H5B, Size 2-1/2 X 5                  Grinnell                18821                  UNK        N/A                UNK      Removed          No Hydraulic Snubber (1) 53A-0-479A-H5B, Size 2-1/2 X 5                  Anvil                  36155                  UNK        UTC                UNK      Installed        No Hydraulic Snubber                                                                                              1082296 J
: 7. Description of Work Replaced existing hydraulic snubber with a new, Config. A pressurized cylinder snubber.
: 8. Test Conducted LI    Hydrostatic            FI    Pnuematic              E] Nominal Operating Pressure          L-  Excempt.                Other      Visual Pressure                        PSI                                                Test Temperature                        Deg. F
 
Form NIS-2 Owner's Report for Repair/Replacement Activities As required by the provisions of the ASME Code Section Xl                                                      Work Order Numbe                Sheet 01681624    -  25            Page 2 of 2
: 7. Remarks (Applicable Manufactuerr's Data Reports to be attached)
(2) Replaced entire snubber CERTIFICATION OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI Type Code Symbol Stamp                                                          Not Applicable Certificate of Autherization Number                            Not Applicable                  Expiration Date                Not Applicable Signed      *-                                              J  S1,01                          Date            J//.      f/0 Owner or Owner's Designee, ttle CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and State or province of 1.-5,e7; <*7VEee1A,,Q4                    and employed by                          HSB CT of                              Hartford, Connecticut                              have inspected the components described in the Owner's Report during the period                    5p-to                            --. '-o 7                    , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.
By signing this certificate neither the inspector nor his employer make any warrenty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind rising from or connected with this inspection.
_____________________                        Commision(s)        .
Inspector's Signature                                              National Board, State, Province, and Endorsements Date        ______
 
Form NIS-2 Owner's Report for Repair/Replacement Activities As required by the provisions of the ASME Code Section XI Work Order Numbe                  Sheet 01681624 - 26                        Pagel of 2
: 1. Owner        Duke Power Company                                            2. Plant    Oconee Nuclear Station                                unit 526 South Church Street                                                    7800 Rochestor Hwy Date Charlotte, NC 28201-1006                                                  Seneca, SC 28672                                                    11/15/2006
: 3. Work Performed By                                                                                                    Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street                                                                                                            Not Applicable Charlotte, NC 28201-1006                                                                                  Expiration Date          Not Applicable
: 4. Identification of Systems, ASME Class
                                                    ;ure Injection - High Pressure Portion ,          ASME Class 1 5.
(a) Applicable Construction Cod USAS B31.7                  1969:  Edition,    No      ddenda No  Code Case R/R Activity  1998:  Edition,      ,    Addenda (b) Applicable Edition Section Xl Utilized For (c) Applicable Section XI Codes Cases(s)          None                          "-  C          7
: 6. Identification of Coimponents Name of Component                        Manufactur:            Manufacture          National      Other            Year      Corrected,      ASME Code Serial Number        Board No    identification      Built  Removed or          Stamped Installed        (Yes/No)
(2) 53A-0-481A-H40C, Size 2-1/2 X                    Grinnell                18801                UNK          N/A                UNK      Removed          No 5 Hydraulic Snubber Cylinder (New Miller)
(1) 53A-0-481A-H40C, Size 2-1/2 X                    Anvil                36540                  UNK          UTC                UNK      Installed        No 5 Hydraulic Snubber Cylinder                                                                                    1823529 (Config. A)
: 7. Description of Work Rebuilt existing snubber cylinder with a Config. A pressurized cylinder.
: 8. Test Conducted FD    Hydrostatic            Li    Pnuematic              E] Nominal Operating Pressure            El  Excempt        [      Other      Visual Pressure                          PSI                                                Test Temperature                        Deg. F
 
Form NIS-2 Owner's Report for Repair/Replacement Activities .
As required by the provisions of the ASME Code Section XI Work Order Numbe                Sheet 01681624      -  26            Page2of2
: 7. Remarks (Applicable Manufactuerr's Data Reports to be attached)
(2) Replaced existing snubber cylinder with Config. A type.
CERTIFICATION OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI Type Code Symbol Stamp                                                              Not Applicable Certificate of Autherization Number                            Not Applicable                      Expiration Date                Not Applicable Signed      1                  Y                    -*A                                          Date        L/zI        /'rc Owner or Owner's Designee, Ti e CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and State or province of AbeT'/                  ,_',,.4J,,          and employed by                          HSB CT of                              Hartford, Connecticut                                  have inspected the components described in the Owner's Report during the period                  9-z*, _or..                to 3-/,-o7                                , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the inspector nor his employer make any warrenty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind rising from or connected with this inspection.
Commision(s)          A,./-',9#Ul
                                                                                  *-,      '. ,
                    .co s Signature                                                    National Board, State, Province, and Endorsements Date J/ V-o o2
 
'Form NIS-2 Owner's Report for Repair/Replacement Activities As required by the provisions of the ASME Code Section Xl Work Order Numbe                Sheet 01681624 - 27 Page 1 of 2
: 1. Owner        Duke Power Company                                            2. Plant    Oconee Nuclear Station                                  Unit 526 South Church Street                                                    7800 Rochestor Hwy Date Charlotte, NC 28201-1006                                                  Seneca, SC 28672                                                      11/15/2006
: 3. Work Performed By                                                                                                      rype Code Symbol Stamp Not. Applicable Duke Power Company Authorization Number 526 South ChurchStreet                                                                                                              Not Applicable Charlotte, NC 28201-1006                                                                                  Expiration Date          Not Applicable
: 4. Identification of Systems, ASME Class
                                                    .r Bldg. Spray - Low Pressure Portion          ,  ASME Class 2 5.
(a) Applicable Construction Cod    USAS B31.-7              1969:  Edition,  No      Addenda No    Code Case (b) Applicable Edition Section XI Utilized For R/R Activity  1998:  Edition,  M      Addenda (c) Applicable Section XI Codes Cases(s)          None
: 6. Identification of Coimponents Name of Component                        Manufactur:          Manufacture            National      Other            Year      Corrected,        ASME Code Serial Number          Board No    identification      Built    Removed or          Stamped Installed        (Yes/No)
(1) 548-0-477-H9A, Size 2-1/2 X 5                  Grinnell                18805                  UNK          N/A                UNK      Removed          No Hydraulic Snubber (2) 54B-0-477-H9A, Size 2-1/2 X 5                  Anvil                                          LI*
UNK          UTC                UNK      Installed        No Hydraulic Snubber                                                                                              1824027
: 7. Description of Work Replaced existing hydraulic snubber with a new, Config. A pressurized cylinder snubber.
: 8. Test Conducted
          -] Hydrostatic            F]    Pnuematic              E] Nominal Operating Pressure            E]  Excempt          [      Other      Visual Pressure                          PSI                                                  Test Temperature                        Deg. F
 
Form N IS-2 Owner's Report for Repair/Replacement Activities As required by the provisions of the ASME Code Section XIWork                                                          Order Numbe              Sheet .
01681624    -  27              Page 2 of 2
: 7. Remarks (Applicable Manufactuerrs Data Reports to be attached)
(1) Replaced entire snubber CERTIFICATION OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI                                                ..
Type Code Symbol Stamp                                                            Not Applicable Certificate of Autherization Number                          Not Applicable                      Expiration Date                Not Applicable Signed                                            .    ,                                      Date            I//z/ /eor Owner or Owner's Designee, Title CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and State or province of l'ox*;-              f,'    c,6 /- 1,AA    and employed by                          HSB CT of                              Hartford, Connecticut                                have inspected the components described in the Owner's Report during the period                      4- Z-L -0o.          to      .2- /5'- 07                      , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the inspector nor his employer make any warrenty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind rising from or connected with this inspection.
Commision(s)          A/ef,    **/-'    ,'V/"C.
Inspector's Signature                                                National Board, State, Province, and Endorsements Date      , -,--o?
 
Form NIS-2 Owner's Report for Repair/Replacement Activities As required by the provisions of the ASME Code Section XI i  WorK Order Numue Sheet 01681624 - 28                        Page I of 2
: 1. Owner      Duke Power Company                                            2. Plant    Oconee Nuclear Station                                    unit 526 South Church Street                                                    7800 Rochestor Hwy Date Charlotte, NC 28201-1006                                                  Seneca, SC 28672                                                      11/15/2006
: 3. Work Performed By                                                                                                      Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street                                                                                                              Not Applicable Charlotte, NC 28201-1006                                                                                    Expiration Date          Not Applicable
: 4. Identification of Systems, ASME Class
                                                    ,r Bldg. Spray - Low Pressure Portion          ,  ASME Class 2 5.
(a) Applicable Construction Cod USAS B31.7                  1969:  Edition,  No      Addenda No    Code Case (b) Applicable Edition Section XI Utilized For RIR Activity 1998:  Edition,          Addenda (c) Applicable Section XI Codes Cases(s)          None                                      7
: 6. Identification of Coimponents Name of Component                        Manufactur:            Manufacture          National        Other            Year      Corrected,      ASME Code Serial Number        Board No    identification      Built    Removed or          Stamped Installed        (Yes/No)
(2) 54B-0-477-H9B, Size 2-112 X 5                  Grinnell                18783                  UNK        N/A                UNK      Removed          No Hydraulic Snubber (1) 54B-0-477-H9B, Size 2-1/2 X 5                  Anvil                36256                    UNK        UTC                UNK      Installed        No Hydraulic Snubber                                                                                              1824029
: 7. Description of Work Replaced existing hydraulic snubber with a new, Config. A pressurized cylinder snubber.
: 8. Test Conducted FD    Hydrostatic            D    Pnuematic              [  Nominal Operating Pressure            ED  Excempt          V      Other      Visual Pressure                          PSI                                                Test Temperature                          Deg. F
 
-Form NIS-2 Owner's Report for Repair/Replacement Activities As required by the provisions of the ASME Code Section XI                                                                  k Order Numbe              Sheet 01681624    -  28            Page2of2
: 7. Remarks (Applicable Manufactuerr's Data Reports to be attached)
(2) Replaced entire snubber CERTIFICATION OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, SectionXI                              -.          .-
Type Code Symbol Stamp                                                                  Not Applicable Certificate of Autherization Number                              Not Applicable                        Expiration Date                Not Applicable Signed        _        _        ____                *',--;"      _        . "                      Date          ///*/          /t    "
Owner or Owner's Designee, Title CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and State or province of A./or,,' e,*,*94,aeo                            and employed by                          HSB CT of                                  Hartford, Connecticut                                  have inspected the components described in the Owner's Report during the period                          /-to 2'-6                t                                          , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the inspector nor his employer make any warrenty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind rising from or connected with this inspection.
Commision(s)          ,-/*'/,',,,,.
Inspector's Signature                                                      National Board, State, Province, and Endorsements Date        ,-Y-o
 
                                                                                                                                            -4 Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number              Sheet 98793766 or 1678290                  1 of 2
: 1. Owner                                              2. Plant                                                  Unit Duke Power Company                                    Oconee Nuclear Station                                  ONS - 1 526 South Church Street                              7800 Rochester Hwy                              Date Charlotte, NC 28201-1006                              Seneca, SC 29672                                      8/1/2006
: 3. Work Performed by                                                            Type Code Symbol Stamp Not Applicable Duke Power Company                                                    Authorization Number 526 South Church Street                                                                  Not Applicable Charlotte, NC 28201-1006                                              Expiration Date Not Applicable
: 4. Identification of System, ASME Class Reactor Coolant, ASME Class 1 5.
(a) Applicable Construction Code:          USAS B31.7          19    69  Edition,      No    Addenda,      No      Code Case (b) Applicable Edition Section Xl Utilized For R/R Activity      19    98  Edition,      2000    Addenda.
(c) Applicable Section Xl Code Case(s)        None
: 6. Identification of Components Name of              Name of          Manufacturer        National            Other.        Year      Corrected,      ASME Component          Manufacturer      Serial Number        Board No.      Identification      Built    Removed,          Code or Installed    Stamped (Yes / No)
Hanger 1                DPC                None              None                None        2006      Installed        NO 479D-H6662 Hanger 1                DPC                None              None                None        2006      Installed        NO 479D-H6663 Hanger 1                DPC                None              None                None        2006      Installed        NO 479D-H6664 BwI, ILP-167                Iner                F460AI41            None                None          1998      Removed          NO International                            N ILP-172                  Flowserve            56AXD              None                None        2003      Removed          NO ILP-173                  Flowserve            69AYL              None                None        204*Removed                  NO 1/2" Sch 160 pipe          DPCo.                Unk              Unk                Unk          2006      Installed        NO and parts Hanger 1      479D-H6665 (see            DPC                None              None                None        2006      Corrected          NO Remark #1)
Hanger 1      479D-H6666 (see            DPC                None              None                None        2006      Corrected        NO Remark #2).        1        1        1      -                          II
: 7. Description of Work        I, Remove portion of 1/2" LPI pipe and valves (ILP-167, 1LP-172 and ILP-173) per OD100885.
-  p 1W 8. Test Conducted DlHydrostatic      1 Pneumatic      H Nominal Operating Pressure      Z  Exempt      0  Other  visual leak inspection Pressure                PSI              Test Temperature                  OF
 
                                                                                                                                            .1 Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number                  Sheet 98793766 2 of    2
: 9. Remarks (Applicable Manufacturer's Data Reports to be attached)
: 1) 7/8" x 12" Fig 137 U-bolt (UTC 1092642), TS 3 x3 x 1/4, 3' x 3/4" Lg. (UTC 1091175), angle 2 x 2 x 1/4 1' Lg. (UTC 1090973),
3/4 x x 6 x 1'-4-3/4" Lg. (UTC 1091175), angle 2" x 2' x 1/4" x 4" Lg. (UTC 107929), 1/4" x 1/2" Fig.137 U-bolt (UTC 1077213).
: 2) angle 2" x 2" x 1/4" x 1'-9" Lg. (UTC 10779929), angle 2 x 2 x 1/4 x 9" Lg. (UTC 10779929), 2 plates 3/4" x 1/2" 4" Lg.(UTC 1091175)
- h CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.
Type Code Symbol Stamp                                                    Not Applicable Certificate of Authorization Number                Not Applicable              Expiration Date              Not Applicable Signed      /      ivx          LZ                                Engineer    Date                      8/1/2006 Owner of Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of          .      .                      and employed by                    HSB CT of                                Hartford, Connecticut                                have inspected the components described in this Owner's Report during the period                6--/''- o10            to    _      -yZF'-_68                  , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
Commissions      x-)(/,-'-1/1,*AI.,/e'l
                    -- tnpstr' ignature                                                  National Board, State, Province, and Endorsements Date        Y-    f ,&#xfd;d
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number                Sheet 1742568                      1 of 2
: 1. Owner                                                2. Plant                                                      Unit Duke Power Company                                      Oconee Nuclear Station                                    ONS - 1 526 South Church Street                                7800 Rochester Hwy                                  Date Charlotte, NC 28201-1006                                Seneca, SC 29672                                          4-30-08
: 3. Work Performed by                                                                  Type Code Symbol Stamp Not Applicable Duke Power Company                                                        Authorization Number 526 South Church Street                                                                        Not Applicable Charlotte, NC 28201-1006                                                  Expiration Date Not Applicable
: 4. Identification of System, ASME Class Reactor Coolant, ASME Class 1 5.
(a) Applicable Construction Code:          ASME Section III        19  83      Edition,      No      Addenda,      No      Code Case (b) Applicable Edition Section Xl Utilized For R/R Activity        19  98      Edition,      2000      Addenda.
(c) Applicable Section Xl Code Case(s)          N-504-2 and N638-1
: 6. Identification of Components Name of                Name of          Manufacturer        National                Other            Year    Corrected,        ASME Component            Manufacturer      Serial Number      Board No.          Identification        Built    Removed,        Code or Installed    Stamped (Yes / No) mm                        1~              +                                      t                      4.                      4.
Reactor Coolant Hot L*eg 12"                                                                            Weld #
Decay Heat                    B&W                None            None                1-PHB- 17          1974    Corrected        No Nozzle butt weld                                                                    1-LP-140-1A to pipe            -+                  .4.                .4.                4                      4.        4              4
: 4.              4                  4.                4                      4.        4              4
: 7. Description of Work Install full structural Alloy 52M weld overlays over the existing Alloy 82/182 butt welds.
: 8. Test Conducted
[    Hydrostatic    Li Pneumatic          Nominal Operating Pressure      Eli  Exempt    [I  Other Pressure                PSI              Test Temperature                      OF
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI I
Work Order Number                  Sheet 01742568                    2 of 2
: 9. Remarks (Applicable Manufacturer's Data Reports to be attached) 0 0
0 0
Q 0
0
&sect; CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.
Type Code Symbol Stamp                                                        Not Applicable Certificate of Authorization Number                        Not Applicable            Expiration Date              Not Applicable Signed        L. S. White, Engineer                      t                        Date                      4-30-08 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of                ,,1b/o,1.'1 6    ,,,,'      and employed by                    HSB CT of                                        Hartford, Connecticut                          have inspected the components described in this Owner's Report during the period                      f-,'e - 0 7          to      ,;.- S- o08                    , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
________________________Commissions                                        A,/9/,",              ',
                    -`csp              Signature                                      National Board, State, Province, and Endorsements Date    __      __-        _    __      __
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI F-Work Order Number                    Sheet 1767520                          I of 2 q                                                                S wner                                              2. Plant                                                        Unit Duke Power Company                                      Oconee Nuclear Station                                        ONS-    I
            .,526 South Church Street                                7800 Rochester Hwy                                    Date Charlotte, NC 28201-1006                                Seneca, SC 29672                                          5/19/2008
: 3. Work Performed by                                                              Type Code Symbol Stamp Not Applicable Duke Power Company                                                      Authorization Number 526 South Church Street                                                                      Not Applicable Charlotte, NC 28201-4006                                                Expiration Date Not Applicable
: 4. Identification of System, ASME Class 1A ROTSG, ASME Class 1 5.
(a) Applicable ConstrUction Code:        ASME Section III        19  89    Edition,      No      Addenda,          No      Code Case (b) Applicable Edition Section Xl Utilized For R/R Activity        19  98    Edition,      2000      Addenda.
(c) Applicable Section Xl Code Case(s) .      None______
: 6. Identification of Components Name of              Name of        Manufacturer          National            Other            Year      Corrected,          ASME Component            Manufacturer      Serial Number        Board No.      Identification        Built    Removed,              Code or Installed      Stamped (Yes / No) mm                      4                  1                    4            4                      4          L                  I Primary Handhole UNK                UNK                UNK                None          UNK          Removed              NO Stud UTC 1063781 Primary Stud    Handhole          UNK                None              None            HT# 1B18-2        2008        Installed            NO
_  __ _              ~4g                      _  _  _      _    _  _    _  _  _
: 7. Description of Work Replaced IA SG Primary Handhole Stud with new from stock due to damaged threading on old stud.
Wi
: 8. Test Conducted H-ydrostatic    1ii Pneumatic NNominal Operating Pressure 0Exempt                    E Other Pressure      2155      PSI              Test Temperature          532      OF
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI I                I Work Order Number                  Sheet 1767520                    2 of 2 1
9.. Remarks (Applicable Manufacturer's Data Reports to be attached) o  Studs are ASME SA193 GR B7 material 0
9 0
9 0
19 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.
Type Code Symbol Stamp                                                      Not Applicable Certificate of Authorization Number                  Not Applicable                Expiration Date              Not Applicable Signed                                                  Aaron Best, Engineer      Date                      5/19/2008 Owner or Owncr>' Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of A,,e;,rl'                      ,4,9o*, and employed by                      HSB CT of                                  Hartford, Connecticut                                have inspected the components described in this Owner's Report during the period                      "f,/-/5'            to      ,- a- o&                      ,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
Commissions          -C            ,.gc-Inspector's Signature                                            National Board, State, Province, and Endorsements Date          ?_- od6 I
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI p
Work Order Number              Sheet 1723307                SI    of 2
: 1. Owner                                              2. Plant                                                    Unit Duke Power Company                                      Oconee Nuclear Station                                  ONS - 1 526 South Church Street                                7800 Rochester Hwy                              Date Charlotte, NC 28201-1006                              Seneca, SC 29672                                      4/22/2008
: 3. Work Performed by                                                              Type Code Symbol Stamp Not Applicable Duke Power Company                                                      Authorization Number 526 South Church Street                                                                  Not Applicable Charlotte, NC 28201-1006                                                Expiration Date Not Applicable
: 4. Identification of System, ASME Class Reactor Coolant System, ASME Class 1 5.
(a) Applicable Construction Code:          USAS B31.7            19    69  Edition,      No    Addenda,      No      Code Case (b) Applicable Edition Section XI Utilized For R/R Activity      19    98  Edition,      2000    Addenda.
(c) Applicable Section Xl Code Case(s)        None
: 6. Identification of Components Name of              Name of        Manufacturer        National            Other        Year    Corrected,        ASME Component            Manufacturer      Serial Number      Board No.        Identification    Built    Removed,          Code or Installed    Stamped (Yes / No)
Orifice Flange Up            UNK                UNK              UNK                  UNK          2008      Corrected          NO Stream 1HP-326
: 7. Description of Work Seal weld orifice plug
: 8. Test Conducted F-1 Hydrostatic      [:1 Pneumatic    ElI Nominal Operating Pressure    E] Exempt      H Other  Visual Leak Test Pressure                PSI              Test Temperature                OF
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI I Work Order Number
                                                                                                                        'I Sheet I
1723307                      2 of    2
: 9. Remarks (Applicable Manufacturer's Data Reports to be attached) o  Welded existing plug in place after cleaning threads.
0 0
0 0
0 0
CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.
Type Code Symbol Stamp                                                      Not Applicable Certificate of Authorin    tion Number              Not Applicable              Expiration Date                Not Applicable Signed                                                                Engineer    Date                      4/22/2008
                        -Owner or O=n47 Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of A              /,aer Z ,' eoz .IoA      and em ployed by                      H SB CT*
of                                Hartford, Connecticut                                have inspected the components described in this Owner's Report during the period        _,__            _'_        o_  to      5/11.-,0        ,              , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
                                  ~                        Com m issions ,V /' /",          -,"
Inspector's Signature                                            National Board, State, Province, and Endorsements Date        e___112_
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number              Sheet
                  /                                                                      01765548                    I of 3
: 1. Owner                                              2. Plant                                                Unit Duke Power Company                                  Oconee Nuclear Station                                ONS - 1 526 South Church Street                              7800 Rochester Hwy                            Date Charlotte, NC 28201-1006                            Seneca, SC 29672                                    11/1/2007
: 3. Work Performed by                                                            Type Code Symbol Stamp Not Applicable Duke Power Company                                                  Authorization Number 526 South Church Street                                                              Not Applicable Charlotte, NC 28201-1006                                            Expiration Date Not Applicable
: 4. Identification of System, ASME Class High Pressure Injection (HPI), ASME Class 1 5.
(a) Applicable Construction Code:          USAS B31.7          19  69  Edition,      No    Addenda,      No      Code Case (b) Applicable Edition Section XI Utilized For R/R Activity      19  98  Edition,      2000    Addenda.
(c) Applicable Section XI Code Case(s)        None
: 6. Identification of Components Name of              Name of        Manufacturer        National          Other          Year    Corrected,      ASME Component          Manufacturer      Serial Number      Board No. Identification      Built    Removed,          Code or Installed    Stamped (Yes / No)
Addt'l weld material to all welds on IHP-489 equalizer line and          NA                  NA              NA                NA            NA      Corrected        NO test connection (latter at the valve junction only)
: 7. Description of Work I                                                                        WORK ORDER NUMBER 01765548 SHEET 2 of 3 Add 2-to-I taper welds on all the welds on the subject check valve's equalizer line and the test connection (latter at the
"*valve junction only) prior to performing the HPI full flow test at the startup from the next refueling outage. Issue:
Potential high cycle fatigue (i.e., vibration) - extend of condition item due to the 2HP-487 leak (ref. PIP 0-07-02844)
: 8. Test Conducted
            -] Hydrostatic    1:1 Pneumatic    El Nominal Operating Pressure  LI  Exempt  N  Other  None Pressure                PSI              Test Temperature              OF
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI
- ~
CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.
Type Code Symbol Stamp                                                  Not Applicable Certificate of Authorization Number                  Not ApplijaEble/          Expiration Date              Not Applicable Signed                                    eary LSenior            Engineer    Date                      11/1/2007 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of .,,.,/                6',&, .,.      and employed by                    HSB CT of                                  Hartford, Connecticut                            have inspected the components describe d in this Owner's Report during the period                  /- ~C? -            to      ,      -                        , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
Commissions  ,Af/6      /"9 O*'&_
                      '9 nspector's Signature                                        National Board, State, Province, and Endorsements Date    ___      __    ____S
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASMIE Code Section XI q
Work Order Number              Sheet 01765549                    I of 3
: 1. Owner                                              2. Plant                                                Unit Duke Power Company                                  Oconee Nuclear Station                              ONS - 1 526 South Church Street                              7800 Rochester Hwy                            Date Charlotte, NC 28201-1006                            Seneca, SC 29672                                  11/1/2007
: 3. Work Performed by                                                          Type Code Symbol Stamp Not Applicable Duke Power Company                                                  Authorization Number 526 South Church Street                                                              Not Applicable Charlotte, NC 28201-1006                                            Expiration Date Not Applicable
: 4. Identification of System, ASME Class High Pressure Injection (HPI), ASME Class 1 5.
(a) Applicable Construction Code:          USAS B31.7          19  69  Edition,      No    Addenda,      No      Code Case (b) Applicable Edition Section XI Utilized For R/R Activity      19  98  Edition,      2000    Addenda.
(c) Applicable Section XI Code Case(s)        None
: 6. Identification of Components Name of              Name of        Manufacturer        National          Other        Year    Corrected,        ASME Component          Manufacturer      Serial Number        Board No. Identification    Built    Removed,        Code or Installed    Stamped (Yes / No)
Addt'l weld material to all welds on 1HP-488 equalizer line and          NA                NA                NA              NA            NA      Corrected        NO test connection (latter at the valve junction only)
: 7. Description of Work WORK ORDER NUMBER 01765549 SHEET 2 of 3 Add 2-to-I taper welds on all the welds on the subject check valve's equalizer line and the test connection (latter at the valve junction only) prior to performing the HPI full flow test at the startup from the next refueling outage. Issue:
Potential high cycle fatigue (i.e., vibration) - extend of condition item due to the 2HP-487 leak (ref. PIP 0-07-02844)
: 8. Test Conducted Hydrostatic H'            Eli Pneumatic        Nominal Operating Pressure [- Exempt VOther None Pressure                PSI              Test Temperature              OF
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number                    Sheet 01765549                      3 of 3 I
: 9. Remarks (Applicable Manufacturer's Data Reports to be attached) 0 0
0 0
0 o
0 0
CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.
Type Code Symbol Stamp                                                      Not Applicable Certificate of Authorization Number                      Not AuPln'g" E            Expiration Date              Not Applicable Signed                                                      trou            eer    Date                      11/1/2007 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Av..,rA' t*e.,z,'                          and employed by                    HSB CT of                                      Hartford, Connecticut                            have inspected the components described in this Owner's Report during the period            _____            -_____      to          ---  0__
_--__              , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
_____________________                                        Commissions  __,____,_______,_____-
I"*1nspector's Signature                                        National Board, State, Province, and Endorsements Date          6- *oO
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASMIE Code Section XI" Work Order Number                Sheet 01767662                    I of 2
: 1. Owner                                              2. Plant                                                    Unit Duke Power Company                                      Oconee Nuclear Station                                ONS - I 526 South Church Street                                7800 Rochester Hwy                              Date Charlotte, NC 28201-1006                                Seneca, SC 29672
: 3. Work Performed by                                                            Type Code Symbol Stamp Not Applicable Duke Power Company                                                    Authorization Number 526 South Church Street                                                                  Not Applicable Charlotte, NC 28201-1006                                              Expiration'Date Not Applicable
: 4. Identification of System, ASME Class High Pressure Injection, ASME Class 1 5.
(a) Applicable Construction Code:          USAS B31.7            19  69  Edition,      No      Addenda,      No      Code Case (b) Applicable Edition Section XI Utilized For R/R Activity      19  98  Edition,      2000    Addenda.
(c) Applicable Section Xl Code Case(s)        None
: 6. Identification of Components Name of              Name of        Manufacturer        National            Other.        Year    Corrected,        ASME Component            Manufacturer      Serial Number      Board No.      Identification      Built    Removed,        Code or Installed    Stamped (Yes / No)
IHP-240                Anchor/Darling      E232A-1-10          2023                N/A          1998      Removed          YES IHP-240                  Flowserve            56BAA              1392      UTC #: 1074399      .2004      Installed        YES 1" Schedule 160 SA 376 TP316 SS                                                  None        UTC# 1822069                  Corrected        NO Pipe
: 7. Description of Work Replace valve with a like for like (DMV-521) under PM work order and a section of 1F pipe to assist in re-installing valve.
: 8. Test Conducted F-- Hydrostatic    [: Pneumatic      E]Nominal Operating Pressure    1-- Exempt      [A Other  F/V LEAK CHECK Pressure                PSI              Test Temperature                  OF
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number                    Sheet 1          01767662                      2 of 2
: 9. Remarks (Applicable Manufacturer's Data Reports to be attached) o    1HP-240, DMV-521, Catalog ID: 304993, UTC No.: 1074399, Serial No.: 56BAA 5,43.h -r'      YA',4, 312 2-/P..r 0 1" Schedule 160 pipe, 316 SS, Stock Code #439066, UTC # 1822069 0
0 0
0 0
CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.
Type Code Symbol Stamp                                                            Not Applicable Certificate of Authorization Number                        Not Applicable              Expiration Date              Not Applicable Signed            H      ?v      a6,(o        &#xfd;              , Sr. Tech Specialist  Date                      5/22/2008
                //      Ovner      or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of                                                and employed by                    HSB CT of                                    Hartford, Connecticut                                have inspected the components described in this Owner's Report during the period                      S7, ef'/, S-            to              -/.        /"          , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section X1.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
_________________                                      _              iosv                    1Commissin U      Inspector's Signature V"                                          National Board, State, Province, and Endorsements Date          S__________
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASMIE Code Section XI p
Work Order Number              Sheet 01767663                    I of 2
: 1. Owner                                              2. Plant                                                    Unit Duke Power Company                                    Oconee Nuclear Station                                ONS - I 526 South Church Street                                7800 Rochester Hwy                              Date Charlotte, NC 28201-1006                              Seneca, SC 29672
: 3. Work Performed by                                                              Type Code Symbol Stamp Not Applicable Duke Power Company                                                      Authorization Number 526 SouthChurch Street                                                                    Not Applicable Charlotte, NC 28201-1006                                                Expiration Date Not Applicable
: 4. Identification of System, ASME Class High Pressure Injection, ASME Class 1 5.
(a) Applicable Construction Code:          USAS B31.7            19  69    Edition,      No    Addenda,      No      Code Case (b) Applicable Edition Section XI Utilized For R/R Activity      19  98    Edition,      2000    Addenda.
(c) Applicable Section X1 Code Case(s)        None
: 6. Identification of Components Name of              Name of        Manufacturer        National            Other          Year    Corrected,        ASME Component            Manufacturer      Serial Number      Board No.      Identification      Built    Removed,        Code or Installed    Stamped (Yes / No)
IHP-246              Anchor/Darling            UNK              UNK                N/A          UNK      Removed          YES IHP-246                  Flowserve            58BAA              1394        UTC #: 1074401      2004      Installed        YES 1" Schedule 160 SA376 TP316 SS                                  None              None        UTC # 1906236                  Corrected        NO Pipe
: 7. Description of Work Replace valve with a like for like (DMV-521) under PM work order and a section of 1" pipe to assist in re-installing the valve.
U U
: 8. Test Conducted F]Hydrostatic      1:1 Pneumatic -  E  Nominal Operating Pressure  ZI  Exempt'    Z  Other  F/V LEAK CHECK Pressure                PSI              Test Temperature                  OF
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number                  Sheet 2 of 2
: 9. Remarks (Applicable Manufacturer's Data Reports to be attached) o  1HP-246, DMV-521, Catalog ID: 304993, UTC No.: 1074401, Serial No.: 58BAA 0 1" Schedule 160 pipe, 316 SS, Stock Code 439066, UTC # 1906236 0
0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.
Type Code Symbol Stamp                                                  Not Applicable Certificate of Authorization Number              Not Applicable              Expiration Date              Not Applicable Sig ned~yi..1-                                          Sr. Tech Specialist  Date                    5/22/2008 6'bwrier or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of                                      and employed by                    HSB CT of                                Hartford, Connecticut                            have inspected the components described in this Owner's Report during the period            t/I 5 q/o 5/                      to                -.                    and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected wit this inspection.
___-          ___C                                  Commissions        i/(//I        /t      A&
U Inspector's Signature                                        National Board, State, Province, and Endorsements Date        V372-' /C) g,
 
Form NIS-2 Owner's Report for Repair/Replacement Activity
  'As required by the provisions of the ASME Code Section XI Work Order Number              Sheet 1        01767938                    I of 2 w -                                                    -
: 1. Owner                                              2. Plant                                                    Unit Duke Power Company                                    Oconee Nuclear Station                                  ONS-    I 526 South Church Street                                7800 Rochester Hwy                                Date Charlotte, NC 28201-1006                              Seneca, SC 29672                                      4/23/2008
: 3. Work Performed by                                                              Type Code Symbol Stamp Not Applicable Duke Power Company                                                      Authorization Number 526 South Church Street                                                                    Not Applicable Charlotte, NC 28201-1006                                                Expiration Date Not Applicable
: 4. Identification of System, ASME Class RCS, ASME Class I 5.
(a) Applicable Construction Code:        ASME Section 111        19    74  Edition,      No      Addenda,      No        Code Case (b) Applicable Edition Section XI Utilized For R/R Activity      19    98  Edition,      2000    Addenda.
(c) Applicable Section XI Code Case(s)        None
: 6. Identification of Components Name of              Name of        Manufacturer        National            Other          Year    Corrected,        ASME Component            Manufacturer      Serial Number        Board No.        Identification      Built    Removed,          Code or Installed    Stamped (Yes / No)
CRDM-37                                    7600023                                                    25UNK                                UNK          UNK      Removed          NO Clsr netAreva CRosure                    Arseva          7602251                IKIKLN                                      nsald          N CRDM-37                                    7600024-0 l-netAreva                              27UNK                                UNK          UNK        Installed        NO ClosureClsr Insert                                247 j
: 7. Description of Work Observed minor galling on CRDM closure insert vent nut threads (PIP 08-2414). Replaced closure insert with spare closure insert, to prevent problems with venting CRDM during unity start-up.
: 8. Test Conducted Fi1 Hydrostatic    E] Pneumatic      E  Nominal Operating Pressure    L--  Exempt    [-] Other Pressure      2155      PSI              Test Temperature          532      OF
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number                  Sheet I            01767938                      2 of  2
: 9. Remarks (Applicable Manufacturer's Data Reports to be attached) o  CRDM #37 closure was removed and new one installed.Stock Code # 17745, UTC # 1006504, Areva Part # 7079271-032 0
0 0
0
&sect; CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section X1.
Type Code Symbol Stamp                                                    Not Applicable Certificate of Authorization Number                  Not Applicable            Expiration Date              Not Applicable S ign ed      X&#xfd;Z                  --            ,  -Date                            _____________aaa CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of                      _Oeq
                                                              &#xfd;                and employed by                    HSB CT of                                    Hartford, Connecticut                            have inspected the components described in this Owner's Report duringthe period                        91-Z 3-06      to      s--      Y-Ia8                  , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied,.
concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
_______________________________                          Commissions .,,        'V -/,            'C.
                "--l    ector's Signature                                        National Board, State, Province, and Endorsements Date        9    Zo
                    -    8
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number                Sheet 1745445                      1 of 2 1
: 1. Owner                                              2. Plant                                                      Unit Duke Power Company                                      Oconee Nuclear Station                                    ONS - 1 526 South Church Street                                  7800 Rochester Hwy                                  Date Charlotte, NC 28201-1006                                Seneca, SC 29672                                        6/26/2008
: 3. Work Performed by                                                                Type Code Symbol Stamp Not Applicable Duke Power Company                                                        Authorization Number 526 South Church Street                                                                      Not Applicable Charlotte, NC 28201-1006                                                  Expiration Date Not Applicable
: 4. Identification of System, ASME Class Reactor Coolant, ASME Class I 5.
(a) Applicable Construction Code:          USAS B31.7            19    69    Edition,      No      Addenda,  ,1*A...      Code Case (b) Applicable Edition Section Xl Utilized For R/R Activity        19    98    Edition,      2000    Addenda.
(c) Applicable Section Xl Code Case(s) Qop,- c.-
: 6. Identification of Components Name of            Name of          Manufacturer          National              Other          Year      Corrected,        ASME Component          Manufacturer        Serial Number        Board No.        Identification        Built    Removed,            Code or Installed      Stamped (Yes / No) 4                  4                  4                +                    4        4                4 Hanger 1                                DPCo.                  N/A              N/A                  N/A          UNK      Corrected            NO 481A-H6489
  -                    4                  4                  4                +                    4        4                4 4                  4                  4                .4                    4        4 4                  4                  4                4                    4        4                4.
I                  1                  4                .4                    4        4                4.
: 7. Description of Work Replaced bent hanger rod on 1-50-481A-H6489.
- m
: 8. Test Conducted L] Hydrostatic      -- Pneumatic        l  Nominal Operating Pressure    H Exempt        Li  Other Pressure                  PSI              Test Temperature                    OF
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI I                                  I Work Order Number                  Sheet 1745445                      2 of 2
: 9. Remarks (Applicable Manufacturer's Data Reports to be attached) 0 1/2" Diameter Carbon Steel, ASTM A36, UTC# 1908169 0
0 0
0 0
0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.
Type Code Symbol Stamp                                                    Not Applicable Certificate of Authorization Number                Not Applicable              Expiration Date              Not Applicable Signed                                                  Aaron Best, Engineer    Date                    6/25/2008 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of A                                      and employed by                    HSB CT of                                Hartford, Connecticut                              have inspected the components described in this Owner's Report during the period                7- 2--o &            to          - e -,2 6                  ,,7and state that to the best. of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
Commissions IV*/f                /A'i        C Inspector's Signature                                        National Board, State, Province, and Endorsements Date      7-Z-- 0'
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section Xl Work Order Number                Sheet
                                              /'I4'/6.ZI e22                  /4                          01742121                      I of 2
: 1. Owner                                              2. Plant                                                      Unit Duke Power Company                                      Oconee Nuclear Station                                    ONS - I 526 South Church Street                                  7800 Rochester Hwy                                Date Charlotte, NC 28201-1006                                Seneca, SC'29672                                        5/24/08
: 3. Work Performed by                                                                Type Code Symbol Stamp Not Applicable Duke Power Company                                                        Authorization Number 526 South Church 'Street                                                                    Not Applicable Charlotte, NC 28201-1006                                                  *Expiration Date
                                                                                          "            Not'Applicable
: 4. Identification of System, ASME Class Steam Generator, ASME Class 1 5.
(a) Applicable Construction Code:        ASME Section III          19  S9    Edition,        No      Addenda,      No      Code Case (b) Applicable Edition Section XI Utilized. For R/R Activity        19    98. Edition,      2000    Addenda.
(c) Applicable Section XI Code Case(s)          None
: 6. Identification of Components Name of              Name of          Manufacturer        National              Other          Year    Corrected,      ASME
    *Component          Manufacturer      Serial Number        Board No.          Identification      Built    Removed,        Code or Installed    Stamped (Yes / No)
Inspection Port Test Cover              B&W Canada            160K- 5              230        PN# 5233549-1          2006      Removed          YES Assembly #11:                                                                    PN# 5233558-1          2 (M9)_________                                                ______          _
Inspection Port Test Cover              B&W Canada            160K- 13              228          PN# 5233753-1        2006 Assembly #10.                                                                                                    Removed          YES (MI 0)
Inspection Port Test Cover B&W Canada            160K-12              227          PN# 5233759          2006      Removed          YES Assembly #9 (R14)
Inspection Port Coe ot#            B&W Canada            006K01                205          PN# 5206081          2003      Installed      YES Inspection Port          B&W Canada            006K01              205          PN# 5206081          2003      Installed      YES Cover @ Port #
Inspection  Port Cover @ Port #          B&W Canada            006K01              205          PN# 5206081          2003      Installed      YES Cover @ Port #
: 7. Description of Work The 3" Instrumented Inspection Port Covers at M9, M 10 and R14 were removed and the original 3" linspection Port Covers were reinstalled..
: 8. Test Conducted
          '-  Hydrostatic  _ EPneumatic        [  Nominal Operating Pressure      L    Exempt    L-- Other Pressure                PSI                Test Temperature                    OF
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number                  Sheet 01742121                        2 of  2
: 9. Remarks (Applicable Manufacturer's Data Reports to be attached) 0 0
0 o
0 o
0 0                                                            CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section X1.
Type Code Symbol Stamp                                                        Not Applicable Certificate of Authorization Number                        Not Applicable            Expiration Date              Not Applicable Signed                                            .        K; W. Rannou/Engineer    Date                      5/24/2008 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of ,tJa.4,,                    ,              and employed by                    HSB CT of                                      Hartford, Connecticut                              have inspected the components described in this Owner's Report during the period                                &7
                                                                            &,--      to        .7- Y- c,.                    , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any. warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected With this inspection.
_________________Commissions                                              Al  .      Yu,*    c.
Inspector's Signature                                          National Board, State, Province, and Endorsements Date            7-        0"6___-__
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As Iequired by the provisions of the ASME Code Section XI        '
U Work Order Number                Sheet 1733992                      I of 2
: 1. Owner                                              2. Plant                                                      Unit Duke Power Company                                      Oconee Nuclear Station                                  ONS - 1 526 South Church Street                                  7800 Rochester Hwy                                Date Charlotte, NC 28201-1006                                Seneca, SC 29672                                        5/14/08
: 3. Work Performed by                                                                Type Code Symbol Stamp Not Applicable Duke Power Company                                                      Authorization Number 526 South Church Street                                                                      Not Applicable Charlotte, NC 28201-1006                                                Expiration Date Not Applicable
: 4. Identification of System, ASME Class High Pressure Injection, ASME Class 1 5.
(a) Applicable Construction Code:          USAS B31.7              19    69  Edition,        No      Addenda,      No      Code Case (b) Applicable Edition Section XI Utilized For R/R Activity        19    98  Edition,      2000    Addenda.
(c) Applicable Section XI Code Case(s)        None
: 6. Identification of Components Name of            Name of          Manufacturer          National              Other          Year    Corrected,        ASME Component          Manufacturer      Serial Number        Board No.        Identification      Built    Removed,        Code or Installed    Stamped (Yes / No)
-~                        1-                1-                  1*                                      t      I I HP VA 0325            Flowserve            98BKJ              2012          UTC 1904117          2008      Installed        YES I" Piping                DPCo.                none              none                none          2008      Installed        NO I HP VA 0325                unk                unk                unk                unk            unk      Removed          NO
: 7. Description of Work The 1" valve I HP-325 and I" pipe were installed to replace a valve with a seat leak.
U  'I
: 8. Test Conducted D-Hydrostatic      E] Pneumatic      -  Nominal Operating Pressure    [7 Exempt        F  Other Pressure                  PSI                Test Temperature                    OF
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI I
Work Order Number                  Sheet 1733992                      2 of    2 I
: 9. Remarks (Applicable Manufacturer's Data Reports to be attached) o  Replaced 1" valve IHP-325 and I" piping due to valve seat leak.
0 0
0 0
0 0
CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.
Type Code Symbol Stamp                                                          Not Applicable Certificate of Authorization Number                  Not Applicable                  Expiration Date              Not Applicable Signed jo..                      TrE.V.NICAL        SP*.IUP          S.,T  If      Date        g..J1.- 08 Owner or Owner' s Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of .,Ar,              I&#xa2;,Z,,JR                  and employed by                    HSB CT of                                Hartford, Connecticut                                      have inspected the components described in this Owner's Report during the period                  ,      .. " '..-,'        to          5_--..-o 8                  ,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
_                                  Commissions                    V/ J/Adc_
Da e-  .ctor's Signature                                                National Board, State, Province, and Endorsements Date      5-5o
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number                Sheet 01765550                      I of 3
: 1. Owner                                              2. Plant                                                    Unit Duke Power Company                                    Oconee Nuclear Station                                  ONS - I 526 South Church Street                              7800 Rochester Hwy                                Date Charlotte, NC 28201-1006                              Seneca, SC 29672                                      11/1/2007
: 3. Work Performed by                                                              Type Code Symbol Stamp Not Applicable Duke Power Company                                                    Authorization Number 526 South Church Street                                                                  Not Applicable Charlotte, NC 28201-1006                                              Expiration Date Not Applicable
: 4. Identification of System, ASME Class High Pressure Injection (HPI), ASME Class 1 5.
(a) Applicable Construction Code:          USAS B31.7          19  69    Edition,      No      Addenda,      No      Code Case (b) Applicable Edition Section Xl Utilized For R/R Activity      19  98    Edition,      2000      Addenda.
(c) Applicable Section XI Code Case(s)        None
: 6. Identification of Components Name of              Name of          Manufacturer        National            Other            Year    Corrected,        ASME Component          Manufacturer        Serial Number      Board No.      Identification      Built    Removed,        Code or Installed    Stamped (Yes I No)
Addt'l weld material to all welds on IHP-487 equalizer line and          NA                  NA              NA                NA            NA        Corrected        NO test connection (latter at the valve junction only) 1*                  4.            t                      4.      4.              4 4                  +                  4
* 4                4 4                  +                  4                                    4.      4                4
: 7. Description of Work WORK ORDER NUMBER 01765550 SHEET 2 of 3 Add 2-to-I taper welds on all the welds on the subject check valve's equalizer line and the test connection (latter at the valve junction only) prior to performing the HPI full flow test at the startup from the next refueling outage. Issue:
Potential high cycle fatigue (i.e., vibration) - extend of condition item due to the 2HP-487 leak (ref. PIP 0-07-02844)
: 8. Test Conducted D  Hydrostatic    LI Pneumatic      1  Nominal Operating Pressure  [-' Exempt      Other  None Pressure                PSI              Test Temperature              OF
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section X1 Work Order Number                    Sheet 01765550"                    3 of 3
: 9. Remarks (Applicable Manufacturer's Data Reports to be attached) 0 00
  &sect; o
0 0
CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the-ASME Code, Section XI.
Type Code Symbol Stamp                                                  Not Applicable Certificate of Authorization Number              t    Not Apaicale            Expiration Date              Not Applicable Signed                                  Geary L. renout Senior Engineer    Date                      11/1/2007 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of .Al/e7' Leoz,,.o.                    and employed by                    HSB CT of                                  Hartford, Connecticut                            have inspected the components described in this Owner's Report during the period                /-Z $' 10k        to        T,3- _-o0                      , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection..
______________                _____________            Commissions  .-
Inspector's Signature                                      National Board, State, Province, and Endorsements Date
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASMIE Code Section XI U-Work Order Number              Sheet 01765551                    1 of 3
: 1. Owner                                              2. Plant                                                  Unit Duke Power Company                                  Oconee NuclearStation                                ONS - 1 526 South Church Street                              7800 Rochester Hwy                              Date Charlotte, NC 28201-1006                            Seneca, SC 29672                                      1/1/2007
: 3. Work Performed by                                                            Type Code Symbol Stamp Not Applicable Duke Power Company                                                  Authorization Number 526 South Church Street                                                                Not Applicable Charlotte, NC 28201-1006                                            Expiration Date Not Applicable
: 4. Identification of System, ASME Class High Pressure Injection (HPI), ASME Class 1 5.
(a) Applicable Construction Code:          USAS 1B31.7          19  69  Edition,      No    Addenda,      No      Code Case (b) Applicable Edition Section XI Utilized For R/R Activity      19  98  Edition,      2000    Addenda.
(c) Applicable Section Xl Code Case(s)        None
: 6. Identification of Components Name of            Name of          Manufacturer        National          Other          Year      Corrected,      ASME Component          Manufacturer        Serial Number      Board No.      Identification    Built    Removed,        Code or Installed    Stamped (Yes / No)
Addt'l weld material to' all welds on IHP-486 equalizer line and          NA                  NA              NA                NA            NA        Corrected        NO test connection (latter at the valve junction only)
 
  '4
: 7. Description of Work WORK ORDER NUMBER 01765551 SHEET 2 of 3 Add 2-to-i taper welds on all the welds on the subject check valve's equalizer line and the test connection (latter at the valve junction only) prior to performing the HPI full flow test at the startup from the next refueling outage. Issue:
Potential high cycle fatigue (i.e., vibration) - extend of condition item due to the 2HP-487 leak (ref. PIP 0-07-02844)
: 8. Test Conducted R  Hydrostatic    0  Pneumatic    LII Nominal Operating Pressure  L] Exempt      Other  None Pressure                PSI              Test Temperature              OF
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number                    Sheet 01765551                      3 of 3
: 9. Remarks (Applicable Manufacturer's Data Reports to be attached) 0 0
0 0
0 O
CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.
Type Code Symbol Stamp                                                      Not Applicable Certificate of Authorization Number                    Not    p~clle              Expiration Date              Not Applicable Signed                                    Geary L. Arfnentrout, Senior Engineer  Date                      11/1/2007 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of zu/oe,                  ,./1*21          and employed by                    HSB CT of                                  Hartford, Connecticut                                have inspected the components described in this Owner's Report during the period                      /-,'-
* to          r-- -&Z                      , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
    -                          C7*                            Commissions    _____-      _____!___________-_--
Inspector's Signature                                          National Board, State, Province, and Endorsements Date      _      --
__-__-      _____
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI a
Work Order Number                Sheet 1768282                      1 of 2 WE                                                      V                                                              'I
: 1. Owner                                              2. Plant                                                      Unit Duke Power Company                                      Oconee Nuclear Station                                    ONS- 1 526 South Church Street                                7800 Rochester Hwy                                  Date Charlotte, NC 28201-1006                                Seneca, SC 29672                                        4/22/2008
: 3. Work Performed by                                                                Type Code Symbol Stamp Not Applicable Duke Power Company                                                      Authorization Number 526 South Church Street                                                                    Not Applicable Charlotte, NC 28201-1006                                                Expiration Date Not Applicable
: 4. Identification of System, ASME Class Reactor Coolant Sample, ASME Class 1 5.
(a) Applicable Construction Code:          USAS B31.7            19    69    Edition,      No      Addenda,        No      Code Case (b) Applicable Edition Section XI Utilized For R/R Activity        19    98    Edition,      2000    Addenda.
(c) Applicable Section XI Code Case(s)        None
: 6. Identification of Components Name of              Name of        Manufacturer          National            Other          Year    Corrected,        ASME Component            Manufacturer      Serial Number        Board No.        Identification      Built    Removed,          Code or Installed    Stamped (Yes / No)
S/R 1-64-479D-                DEC              None                N/A                  N/A          2008      Installed          NO H6347
_ __            I  _    _      _  I  _        _I        _        _    _I  __                I _    _I  __                _
: 7. Description of Work Support removed for PM on 1RC-5. Decided to replace bolts and nuts rather than re-use. As a structural steel bolt it should not be re-used when it was installed per procedure.
F8. Test Conducted
              -Hydrostatic        D Pneumatic    R  Nominal Operating Pressure      E    Exempt      -MOther Pressure              PSI -              Test Temperature                  OF
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number                    Sheet 1768282                      2  of  2 U
: 9. Remarks (Applicable Manufacturer's Data Reports to be attached) o  1/2" A 325 bolt, Cat ID 35885 1/2" A194 2H nuts, Cat ID 313135 0
0 0
0 0
0 0
CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.
Type Code Symbol Stamp                                                    Not Applicable Certificate of Author. ation Number                    Not Applicable            Expiration Date              Not Applicable Signed      6,-6zi/-                  ---
Owner or Owte') Zesignee, Title Engineer    Date                      4/22/2008 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of ,-L/oe rA/' zc,,o-1,,,*'                and employed by                    HSB CT of                                      Hartford, Connecticut                          have inspected the components described in this Owner's Report during the period                      "-z- oe          to        ,s- 0o                    , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
Commissions    ./L/"/Y',!,,,,42*__
                    -- 1-n-K-p-ector's Signature                                      National Board, State, Province, and Endorsements Date      S* e--.  -ca d?
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number              Sheet 01765543                    1 of 3
: 1. Owner                                              2. Plant                                                  Unit Duke Power Company                                    Oconee Nuclear Station                                ONS - 1 526 South Church Street                                7800 Rochester Hwy                              Date Charlotte, NC 28201-1006                              Seneca, SC 29672                                    11/1/2007
: 3. Work Performed by                                                            Type Code Symbol Stamp Not Applicable Duke Power Company                                                    Authorization Number 526 South Church Street                                                                  Not Applicable Charlotte, NC 28201-1006                                              Expiration Date Not Applicable
: 4. Identification of System, ASME Class High Pressure Injection (HPI), ASME Class 1 5.
(a) Applicable Construction Code:          USAS B31.7            19  69  Edition,      No      Addenda,      No      Code Case (b) Applicable Edition Section Xl Utilized For R/R Activity      19  98  Edition,      2000    Addenda.
(c) Applicable Section Xl Code Case(s)        None
: 6. Identification of Components Name of              Name of          Manufacturer        National            Other          Year    Corrected,        ASME Component            Manufacturer      Serial Number      Board No.      Identification      Built    Removed,        Code or Installed    Stamped (Yes / No)
-~                      t                  I                  4              4                    +      I                4 Addt'l weld material to base of the vent/drains containing the valves listed below:
1HP-322                      NA                  NA                NA                NA            NA      Corrected        NO 1HP-323                      NA                  NA,              NA                NA            NA      Corrected        NO 1HP-326                      NA                  NA                NA                NA            NA      Corrected        NO IHP-327                      NA                  NA                NA                NA            NA      Corrected        NO IHP-334                      NA                  NA                NA                NA            NA      Corrected        NO IHP-345                      NA                  NA                NA                NA            NA      Corrected        NO
: 7. Ddscription of Work WORK ORDER NUMBER 01765543 SHEET 2 of 3 Add 2-to-I taper welds to base (i.e., connection of the 1" line to the half-coupling on the 2 1/2" HPI header) of the vent/drains containing the valves listed below:
- I HP-322
- IHP-323
- IHP-326
- IHP-327
- I HP-334
- I HP-345 This preventative work is required as an extend of condition item due the 2HP-487 leak (ref. PIP 0-07-02844). Addition of 2-to-I taper welds provides better vibrational resistance.
: 8. Test Conducted LII Hydrostatic    LI Pneumatic  [-] Nominal Operating Pressure  EL Exempt    0  Other  None Pressure              PSI              Test Temperature                OF
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI                                        . ,
Work Order Number                    Sheet
                          }
* 01765543                      3 of 3
: 9. Remarks (Applicable Manufacturer's Data Reports to be attached) 0 0
0                                                      CO 0
0 0
0 0
            =                                          'CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.
Type Code Symbol Stamp                                                      Not Applicable Certificate of Authorization Number,                    Tjoippoable              Expiration Date              Not Applicable Signed                                      Geary V Armentrout, Senior Engineer    Date                      11/1/2007 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of -              ,,    _-e
                                                                ,,c&Le-voO,        and employed by                    HSB CT of                                    Hartford, Connecticut                              have inspected the components described in this Owner's Report during the period                            8 -o 7        to                                      , and state that to the best of my knowledge, and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the'requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this&#xfd; Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
_____        ____        _____        ____    ____    Commissions    'C/"    './-  )/,&/ r?--
Inspector's Signature                                          National Board, State, Province, and Endorsements Date                c'-o0 8.
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number              Sheet 01739280                      1 of 2
: 1. Owner                                              2. Plant                                                    Unit Duke Power Company                                      Oconee Nuclear Station                                  ONS - 1 526 South Church Street Charlotte, NC 28201-1006                  1.Seneca,    7800 Rochester Hwy SC 29672 Date 4/28/2008
: 3. Work Performed by                                                              Type Code Symbol Stamp Not Applicable Duke Power Company                                                      Authorization Number 526 South Church Street                                                                    Not Applicable Charlotte, NC 28201-1006                                                Expiration Date Not Applicable
: 4. Identification of System, ASME Class Low Pressure Injection, ASME Class 1 5.
(a) Applicable Construction Code:          USAS B31.7            19    69  Edition,      No      Addenda,      No      Code Case (b) Applicable Edition Section XI Utilized For R/R Activity      19    98  Edition,      2000    Addenda.
(c) Applicable Section Xl Code Case(s)        None
: 6. Identification of Components Name of              Name of          Manufacturer        National            Other          Year      Corrected,        ASME Component          Manufacturer        Serial Number      Board No.        Identification      Built    Removed,          Code or Installed    Stamped (Yes / No) mu                        4                  +                  +                                    4      4.                4 Valve ILP-181-          Flowserve          E371A-4-4            2262                UNK            2000      Removed            YES Valve ILP-181          Flowserve              95BJU              1963        UTC 1900429          2007      Installed        YES Valve lLP-180          Flowserve            E371A-4-3            2261              LUNK          2000      Removed            YES Valve ILP-180          Flowserve              98BHR              1788        UTC 1896316          2007      Installed        YES
: 7. Description of Work OE100720 replaced valves 1LP-180, 1LP-181, 1LP-182, 1LP-187, 1LP-188, and 1LP-189 with valve item# 09J-2005.
Note: Valves 1LP-180 and 1LP-181 are ISI Class A. All others are ISI Class B
-  F,
: 8. Test Conducted D  Hydrostatic    1 Pneumatic            Nominal Operating Pressure    0. Exempt'      -- Other Pressure                  PSI              Test Temperature                  OF
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI
- w CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.
Type Code Symbol Stamp                                                Not Applicable Certificate of Authorization Number                  Not Applicable        Expiration Date              Not Applicable Signed                  _/_(Ir4fX, iC      V*  *V*f*
Date      #      1, $
Ownef or Owner's Designee, Title                                I    I CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of ,4Jber.v' L'=.ii.c                  and employed by                    HSB CT of                                  Hartford, Connecticut                        have inspected the components described in this Owner's Report during the period                  6-2o -o7          to            "-.___._"-,      ____    ,I__
and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
Commissions Inspector's Signature                                      National Board, State, Province, and Endorsements Date        f*-  /-5~--  08
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI U --
Work Order Number                Sheet 1738198                    1 of  2
: 1. Owner                                              2. Plant                                                    Unit Duke Power Company                                    Oconee Nuclear Station                                  ONS - 1 526 South Church Street                                7800 Rochester Hwy                                Date Charlotte, NC 28201-1006                              Seneca, SC 29672                                      5/24/2008
: 3. Work Performed by                                                            Type Code Symbol Stamp Not Applicable Duke Power Company                                                    Authorization Number 526 South Church Street                                                                  Not.Applicable Charlotte, NC 28201-1006                                              Expiration Date Not Applicable 4., Identification of System, ASME Class Reactor Coolant, ASME Class 1 5.
(a)  Applicable Construction Code:          USAS B31.1          19  67  Edition,        No    Addenda,      No      Code Case (b)  Applicable Edition Section XI Utilized For R/R Activity      19  98  Edition,      2000    Addenda.
(c)  Applicable Section XI Code Case(s)        None
: 6. Identification of Components Name of              Name of          Manufacturer        National            Other          Year      Corrected,        ASME Component          Manufacturer        Serial Number      Board No.      Identification        Built    Removed,          Code or Installed    Stamped (Yes / No)
(1) S/R 1-50            DPCo.                None            None              None            Unk      Installed        NO 66A-RCPM-S 1 (2) S/R 1-50            DPCo.                None            None              None            Unk      Installed        NO 66A-RCPM-S2 (3) S/R 1-50      ()AR                        DPCo.                None            None              None            Unk 66A-RCPM-S3                                                                                                    Installed        NO 7.
1111_I~I_
Description of Work Add extension pieces and misc structural steel to snubber restraints on RCPM 1Al to provide sufficient tolerance to reinstall snubbers after RCPM replacement. Affected snubbers are 1-50-0-66A-RCPM-S 1, 1-50-0-66A-RCPM-S2 & 1-50-0-66A-RCPM-S3.                                                                                                    /
h- -  8. Test Conducted                                                                            OP V            e-4D 0 FI Hydrostatic      ']Pneumatic      Li Nominal Operating Pressure -    Exe~tliot    [:] Other Pressure                PSI            Test Temperature                    OF
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number                  Sheet Wo        1738198                    2 of 2
: 9. Remarks (Applicable Manufacturer's Data Reports to be attached) o  S/R 1-50-0-66A-RCPM-S 1; added CS plates UTC 1079648 knd UTC 1090733,'added rear brackets UTC 1897948, added extension piece UTC 1904131i, added bolts UTC 1907088.
O S/R 1-50-0-66A-RCPM-S2; added CS plates UTC 1079648, added rear brackets UTC 1897948, added extension piece UTC 1904131, added bolts UTC 1906793 O S/R l-50-0-66A-RCPM-S3; added CS plates UTC1079648,fUTC1819947f UTC1067870 and UTC1821915, added CS sch 80 pipe UTC 182307,1 added CS sch 40 pipe UTC 1832427,'added rear brackets UTC 1902328, "added wedge anchors UTC 1904583;,
added extension piece UTC 1904131, added bolts UTC 1907088 -
0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct. and that this conforms to the requirements of the ASME Code, Section XI.
Type Code Symbol Stamp                                                      Not Applicable Certificat e of Authorization Number                      Not Applicable              Expiration Date              Not Applicable Signed C&#xfd;~k                                                                          Date      si5
                                                                                                    /an~
O"wner or Owner's DesignM, Title CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of ,-,Jcxe.&#xfd;P>                                  and employed by                    HSB CT of                                      Hartford, Connecticut                                have inspected the components described in this Owner's Report during the period                      9.~o7to                                      0________8
___      , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
_________________________Commissions                        _______________
e-"r'Insetr              inature                                            National Board, State, Province, and Endorsements Date    S-_ -e#r__-o
 
Form NIS-2 Owner's Report for Repair/Replacement Activities As required by the provisions of the ASME Code Section XI                                                      Work Order Numbe                Sheet 01812566 - 01                          Pagel    of 2 41h i1.Owner        Duke Power Company                                          2. Plant    Oconee Nuclear Station                                Unit    I 526 South Church Street                                                  7800 Rochestor Hwy Seneca, SC 28672                                      Date    5/27/2008 Charlotte, NC 28201-1006
: 3. Work Performed By                                                                                                  Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street                                                                                                          Not Applicable Charlotte, NC 28201-1006                                                                                Expiration Date          Not Applicable
: 4. Identification of Systems, ASME Class
                                                      ;ure Injection - High Pressure Portion ,        ASME Class 1 5.
(a) Applicable Construction Cod    USAS 831.1              1967:  Edition,  No    Addenda No  Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 1998:  Edition,  2000  Addenda (c) Applicable Section XI Codes Cases(s)          None
: 6. Identification of Coimponents Name of Component                        Manufacturer:          Manufacturer        National      Other            Year      Corrected,        ASME Code Serial Number      Board No    identification      Built    Removed or            Stamped Installed          (Yes/No)
(1) S/R 1-51A-0-479A-H17A-                          Grinnell              36153                UNK          N/A                UNK      Removed            No Grinnell 2 1/2 x 5, Config. A Snubber.
S/R 1-51A-0-479A-H17A- Grinnell 2                    Anvil P    1/2 x 5, Config A Snubber.
36973                UNK          UTC 1909139 UNK      Installed          No
: 7. Description of Work
: 8. Test Conducted D]    Hydrostatic            [] Pnuematic                [  Nominal Operating Pressure          ED  Excempt          [    Other      Visual Pressure                        PSI                                              Test Temperature                          Deg. F
 
Form NIS-2 Owner's Report for Repair/Replacement Activities As required by the provisions of the ASME Code Section Xl                                                      Work Order Numbe                Sheet 01812566      -  01            Page2of2
: 7. Remarks (Applicable Manufactuerr's Data Reports to be attached)
(1) Snubber was replaced due to potential fluid leak.
CERTIFICATION OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI Type Code Symbol Stamp                                                            Not Applicable Certificate of Autherization Number                            Not Applicable                  Expiration Date                  Not Applicable Signed        .                  .1,                                                            Date            ,..          _____
Owner or Owner's Designee, Title CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and State or province of ,,1oPe,,                  ,      ,      and employed by                          HSB CT of                                Hartford, Connecticut                            have inspected the components described in the Owner's Report during the period _                        -__ -___. _to              S-* o80'-                  , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the inspector nor his employer make any warrenty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind rising from or connected with this inspection.
S      Commision(s)        11-&#xfd;W~~c Inspector's Signature                                              National Board, State, Province, and Endorsements Date      &9'-o
 
Form NIS-2 Owner's Report for Repair/Replacement Actlvity As-required-by the provisions of the ASME Code Section XI                                                        U Work Order Number              Sheet 01752873                    1 of 2
: 1. Owner                                              2. Plant                                                  Unit Duke Power Company                                    Oconee Nuclear Station                                ONS - 1
          - 526'South Church Street                              7800 Rochester Hwy                              Date Charlotte, NC 28201-1006                              Seneca, SC 29672                                    7/26/2007
: 3. Work Performed by                                                              Type Code Symbol Stamp Not Applicable Duke Power Company                                                    Authorization Number 526 South Church Street                                                                  Not Applicable Charlotte, NC 28201-1006                                              Expiration Date Not Applicable
: 4. Identification of System, ASME Class LPI, ASME Class 1 5.
(a) Applicable Construction Code:          USAS B31.7            19    69  Edition,      No    Addenda,      No      Code Case (b) Applicable Edition Section XA Utilized For R/R Activity      19    98  Edition,      2000    Addenda.
(c) Applicable Section XI Code Case(s)        None
: 6. Identification of Components Name of            Name of          Manufacturer        National              Other        Year      Corrected,      ASME Componrent          Manufacturer      Serial Number      Board No.        Identification      Built    Removed,        Code or Installed  Stamped (Yes I No)
-I.)53-A--0-47MA-DPCo                None            None                None        UNK      Corrected        NO H2A
: 7. Description of Work OE101817: S/R 53A-0-H2A - Add plates and welds at clip angle connection.
: 8. Test Conducted E] Hydrostatic    L- Pneumatic      -i Nominal Operating Pressure    0] Exempt      L] Other  None required Pressure                PSI              Test Temperature                  OF
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI                                            ....
Work Order Number                  Sheet
: 9. Remarks (Applicable Manufacturer's Data Reports to be attached) o  S/R 53A-0-478A-H2A: add two 1/2" plates to clip angle connection 0
0 0
0 0
0 0
0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the
  ,  ASME Code, Section XI.
Type Code Symbol Stamp                                                  Not Applicable Certificate of Authorization Number                  Not Applicable          Expiration Date              Not Applicable Signed                                                    6s,&#xfd;et,-,          Date        7-            ot      pc Owne or C(xner's;signee, Title
                                ~5.
CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of -L6iv              zeoZ,,A,,,        and employed by                    HSB CT of                                    Hartford, Connecticut                        have inspected the components described in this Owner's Report during the period                    7-./-o7        to          7-,s-- 8                    , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
*
* Commissions ,V'          AJ/Ad"
                    '-"  fispector's Signature                                    National Board, State, Province, and Endorsements Date        7-I"-09
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number                Sheet 01739941                      I of Id.
: 1. Owner                                              2. Plant                                                        Unit Duke Power Company                                    Oconee Nuclear Station                                    ONS - 1 526 South Church Street                                7800 Rochester Hwy                                  Date Charlotte, NC 28201-1006                              Seneca, SC 29672                                          5/24/2008
: 3. Work Performed by                                                                Type Code Symbol Stamp Not Applicable Duke Power Company                                                      'Authorization Number 526 South Church Street                                                                      Not Applicable Charlotte, NC 28201-1006                                                  Expiration Date, Not Applicable
: 4. Identification of System, ASME Class Low Pressure Service Water, ASME Class 2 5.
(a) Applicable Construction Code:          USAS B31.1            19  67      Edition,      No      Addenda,      No      Code Case (b) Applicable Edition Section XI Utilized For R/R Activity      19  98      Edition,      2000      Addenda.
(c) Applicable Section XACode Case(s)          None
: 6. Identification of Components Name of              Name of        Manufacturer        National              Other            Year      Corrected,      ASME Component            Manufacturer      Serial Number      Board No.        Identification        Built    Removed,          Code or Installed    Stamped (Yes / No)
(1) SIR 1-14B-480C-H6492 /                DPCo.              None            None                  None            Unk        Installed        NO (2) SIR 1-14B-()0R-14B-                  DPCo.              None            None                  None            Unk                          N 480C-H6493 v/                                                                                                    Installed        NO
                      *1~                t                  1~                                              4.                4
                    +                    4                  4.                                      4-      .1.
1-              .4.                    4        .4.              4
: 4.                  4                  +                I                    -4        .1.              4
: 7. Description of Work These supports interfered with the replacement of Reactor Coolant Pump Motor (RCPM) I Al. These supports were removed and then reinstalled after RCPM I A1 was replaced.
: 8. Test Conducted FD1 Hydrostatic    D    Pneumatic    E]  Nominal Operating Pressure    Z    Exempt    ED Other Pressure                PSI              Test Temperature                      O____
F
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number                  ISlieet  Z I
1739941                  I2of 1#
: 9. Remarks (Applicable Manufacturer's Data Reports to be attached) 0 SIR 1-14B-480C-H6492; replaced angle UTC8305 19, replaced u-bolts UTO 108709 Iv 0 S/R 1-14B-480C-H6493; replaced beam attachments UTC 1092146 0
0 0
0 B
0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.
Type Code Symbol Stamp                                                  Not Applicable Certificate of Authorization Number                    Not Applicable            Expiration Date              Not Applicable Signed      C2,                      se.tLor                                  Date Dase        b5-Xit  o Own    or*rOwner's Designce, Titl_"
CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of A_,Y,- ,                  L,,,A        and employed by                    HSB CT of                                  Hartford, Connecticut                              have inspected the components described in this Owner's Report during the period                    S..//- ,            to  _      _--___-                      ,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section X1.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
      .*:::~~      ~"_Commissions                                          ,tr//    9W,'.          ",,ef
              '    -n spector's Signature                                          National Board, State, Province, and Endorsements Date      ,S    .-    0c
 
00 Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number              Sheet
                                                                            / .1
                                                                        ;**D76              01740074 I of 2
: 1. Owner                                              2. Plant                                                  Unit Duke Power Company                                    Oconee Nuclear Station                                  ONS - 1 526 South Church Street                                7800 Rochester Hwy                              Date Charlotte, NC 28201-1006                              Seneca, SC 29672                                      5/13/2008
: 3. Work Performed by                                                              Type Code Symbol Stamp Not Applicable Duke Power Company                                                      Authorization Number 526 South Church Street                                                                    Not Applicable Charlotte, NC 28201-1006                                                Expiration Date Not Applicable
: 4. Identification of System, ASME Class Main Steam, ASME Class 2 5.
(a) Applicable Construction Code:            USAS B31.1          19    67  Edition,      No      Addenda,      No        Code Case (b) Applicable Edition Section XI Utilized For R/R Activity      19    98  Edition,      2000    Addenda.
(c) Applicable Section XI Code Case(s)          None
: 6. Identification of Components Name of              Name of          Manufacturer        National            Other          Year    Corrected,        ASME Component          Manufacturer        Serial Number      Board No.      Identification      Built    Removed,          Code or Installed    Stamped (Yes / No)
                      $                  $                  4                                    4      4-                +
(1) Piping                  DP Co                UNK              none                none          2008      Installed        NO (2) Valve IMS-            Flowserve            55AYN            1311          UTC 1070799        2004      Installed        YES IV-0423 (2) Valve I MS-          Flowserve            63AYN            1327          UTC 1069489        2004      Installed        YES IV-0424
: 7. Description of Work OD101701 - Replaced Class B 1/2" piping and valves with a 2" half coupling, 2" piping, two 2" valves (IMS-IV-0423, IMS-IV-0424) with Item # 06G-2004, and a 2" x I" reducing insert. 1/2" tubing was then reconnected.
: 8. Test Conducted D  Hydrostatic          Pneumatic    F1 Nominal Operating Pressure    D Exempt        E  Other Pressure                PSI              Test Temperature                  &deg;F
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section X1 Work Order Number                    Sheet I          01740074                      2 of 2
: 9. Remarks (Applicable Manufacturer's Data Reports to be attached) 0 2" CS A-]06 Br. B pipe (UTC 948291), 2" x 1" SA-l05 reducing~ins'ert, and 2" SA-105 halfcoupling (UTC 1891155)
@ Which serial number valve went to which valve location confirmed through phone conversation with Craft.
0 0
0 0
CERTIFICATE OF COMPLIANCE I certify  that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.
Type Code Symbol Stamp                                                    Not Applicable Certificate of Authorization Number                  Not Applicable              Expiration Date              Not Applicable Signed      Wd,]*        td* /! ./ -        ''                                Date          &1_ 708)
Owner dr Ownetrs Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of /.1J0X7 6e&#xa2;,.d._v,                      and employed by                      HSB CT of                                  Hartford, Connecticut                              have inspected the components described in this Owner's Report during the period                  & -2 7- 07            to      tg -.5 08                      , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
____ ___    ___    ___    ___    ___  ___  ___    Commissions  -__j    _  __  __    ___/__          __-_      __  __
Inspector's Signature                                        National Board, State, Province, and Endorsements Date '    _____-            ____
 
Form NIS-2 Owner's Report for Repair/Replacement Activities
                                                                                                                                        -I.
As required by the provisions of the ASME Code Section XI                                                          W  -d    N..
Sheet 01812566 - 02                          Page 1 of 2 I&
: 1. Owner        Duke Power Company                                            2. Plant    Oconee Nuclear Station                                    Unit I                  526 South Church Street                                                  7800 Rochestor Hwy Date    5/27/2008 Charlotte, NC 28201-1006                                                  Seneca, SC 28672
: 3. Work Performed By      "T                                                                                                  I ype Code Symbol Stamp      Not N Applicabie Duke Power Company Authorization Number      Not Applicable 526 South Church Street Charlotte, NC 28201-1006                                                                                  Expiration Date            Not Applicable
: 4. Identification of Systems, ASME Class Main Steam    ,    ASME Class 2 5.
(a) Applicable Construction Cod USA$ B31.1                  1967:    Edition,  No    Addenda No    Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 1998:    Edition,  2000    Addenda (c) Applicable Section Xl Codes Cases(s)          None
: 6. Identification of Coimponents Name of Component                        Manufacturer:          Manufacturer          National        Other          Year      Corrected,      ASME Code Serial Number        Board No    identification      Built      Removed or        Stamped Installed        (Yes/No)
(1) S/R 1-01A-0-481B-H12A-                            Grinnell              35032                  UNK          N/A                UNK        Removed          No Grinnell 4 x,10,,Config. A Snubber.
S/R 1-01A-0-481B-H12A - Grinnell 4                  Anvil                  35079                  UNK          UTC                UNK        Installed        No x 10, Config. A Snubber.                                                                                        1038117
: 7. Description of Work
: 8. Test Conducted LII  Hydrostatic            LI  Pnuematic              LI  Nominal Operating Pressure            LI  Excempt          [      Other      Visual Pressure                          PSI                                                  Test Temperature                          Deg. F
 
Form NIS-2 Owner's Report for Repair/Replacement Activities As required by the provisions of the ASME Codle Section XI                                                    Work Order Numbe                Sheet B i01812566                                                                                              -02                Page 2 of 2
: 7. Remarks (Applicable Manufactuerres Data Reports to be attached)
(1) Snubber was replaced due to fluid leak.
CERTIFICATION OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl Type Code Symbol Stamp                                                          Not Applicable Certificate of Autherization Number                            Not Applicable                  Expiration Date                Not Applicable Signed      /                                ,_                                                Date                  ,___  ___/__            _
Owner or Owner's Designee, Title CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and State or province of A.-rW                  qoe,,uA            and employed by                          HSB CT of                              Hartford, Connecticut                              have inspected the components described in the Owners Report during the period                      ,._-_2___    _      to      .d - &#xfd;P,-d                        , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the inspector nor his employer make any warrenty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind rising from or connected with this inspection.
                    ~~~~~~~~Commision(s),,'//"/,,,.,*,C.
Inspector's Signature                                              National Board, State. Province, and Endorsements Date    &" oU
 
        /                        jwner's Report for Repair/Replacement Activities V
                              ,rovisions of the ASME Code Section XI                                              IWork  Order Numbe                Sheet 01742798
@1!                                                                                                                                    -13 Page 1 of 2 unit uke Power Company                                          2. Plant    Oconee Nuclear Station                                Unit 526 South Church Street                                                  7800 Rochestor Hwy Date    5/6/2008 Charlotte, NC 28201-1006                                                Seneca, SC 28672 dork Performed By                                                                                                  Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street                                                                                                          Not Applicable Charlotte, NC 28201-1006                                                                                Expiration Date Not Applicable
: 4. Identification of Systems, ASME Class Main Steam ,    ASME Class 2 5.
(a) Applicable Construction Cod    USAS B31.1              1967:  Edition,  No    Addenda No  Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 1998:  Edition,  2000    Addenda (c) Applicable Section Xl Codes Cases(s)          None
: 6. Identification of Coimponents Name of Component                        Manufacturer:          Manufacturer        National      Other          Year      Corrected,      ASME Code Serial Number      Board No    identification      Built    Removed or          Stamped Installed        (Yes/No)
(1) Lisega Hydraulic Snubber 1-01Ao                Lisega                01615040/050          UNK          N/A                UNK      Removed          No 0-550-R5.
(2) Lisega Hydraulic Snubber 1-01A-                  Lisega              046165931006          UNK          UTC                UNK      Installed        No 0-550-R5.                                                                                                    1897045
: 7. Description of Work Replace Lisega Snubber due to leaking seals.
: 8. Test Conducted D    Hydrostatic            D    Pnuematic              D  Nominal Operating Pressure          ED  Excempt          91    Other      Visual Pressure                          PSI                                              Test Temperature                        Deg. F
 
F orm NIS-2 Owner's Report for Repair/Replacement Activities As required by the provisions of the ASME Code Section X1                                                      Work Order Numbe                Sheet 01742798 -13                  Page 2 of 2
: 7. Remarks (Applicable Manufactuerr's Data Reports to be attached)
(1) Replace Lisega Snubber due to leaking seals.
CERTIFICATION OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl Type Code Symbol Stamp                                                          Not Applicable Certificate of Autherization Number                          Not Applicable                    Expiration Date                  Not Applicable Signed        _________________                                                        D        Date            --.          ______
Owner or Owners Designee, Title CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler'and Pressure Vessel Inspectors and State or province of ,,1oJe),A)          ,          ,zs.4    and employed by                          HSB CT of                              Hartford, Connecticut                              have inspected the components described in the Owner's Report during the period                        -      .Z1?'-    to      d          -                    , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures, described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.
By signing this certificate neither the inspector nor his employer make any warrenty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither, the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind rising from or connected with this inspection.
                                            ~      Commision(s)        .                ,-
inspectors Signature                                                National Board, State, Province, and Endorsements Date              -
 
Form NIS-2 Owner's Report for Repair/Replacement Activities As required by the provisions of the ASME Code Section XI                                                          Work Order Numbe                Sheet 01776264 - 03                          Pagel    of 2
: 1. owner        Duke Power Company                                              2! Plant    Oconee NUcle*r Station                                Unit 526 South Church Street                                                    7800 Rochestor Hwy Oats    5/6/2008 Seneca, SC 28672 Charlotte, NC 28201-1006
: 3. Work Performed By                                                                                                      Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street                                                                                                              Not Applicable Charlotte, NC 28201-1006                                                                                  Expiration Date          Not Applicable
: 4. Identification of Systems, ASME Class
                                                    ;ure Injection - High Pressure Portion            ASME Class 2 5.
(a) Applicable Construction Cod    USAS B31.1                1967:    Edition,  No      Addenda No  Code Case (b) Applicable Edition Section XI Utilized For R/R Activity  1998:    Edition,  2000    Addenda (c) Applicable Section XI Codes Cases(s)          None
: 6. Identification of Coimponents Name of Component                        Manufacturer:            Manufacturer        National      Other            Year      Corrected,        ASME Code Serial Number      Board No    identification      Built  Removed or            Stamped Installed          (Yes/No)
(1) Replace Snubber 1-53A-0-479A-                  Grinnell                  18799                UNK          N/A                UNK      Removed            No H5A.
(2) Replace Snubber 1-53A-0-479A-                  Anvil                    36608                UNK          UTC                UNK      Installed          No H5A.                                                                                                            1833340
: 7. Description of Work Replaced snubber due to seal life.
: 8. Test Conducted FD    Hydrostatic            D]  Pnuematic                Ij  Nominal Operating Pressure          D  Excempt          [      Other      Visual Pressure.                        . PSI                                                Test Temperature                          Deg. F
 
Form NIS-2 Owner's Report for Repair/Replacement Activities As required by the provisions of the ASME Code Section Xl                                                        Work Order Numbe                Sheet 01776264    -  03              Page 2 of 2
: 7. Remarks (Applicable Manufactuerr's Data Reports to be attached)
(1) Replaced snubber due to seal life.
CERTIFICATION OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl Type Code Symbol Stamp                                                            Not Applicable Certificate of Autherization Number                            Not Applicable                      Expiration Date                Not Applicable Signed        /0q9f4'                    ..                                                        ae        _    1
__      _    _    _    _  _
Owner or Owners Designee, Title CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and State or province of A-'0rA,'o                eeoe-*,      -,J and employed by                          HSB CT of                                Hartford, Connecticut                              have inspected the components described in the Owner's Report during the period' .- ,J-                            l      to          - 5,.
                                                                                                          ,6' 0                    , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.
By signing this certificate neither the inspector nor his employer make any warrenty, expressed or implied, concerning the examinations andcorrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind rising from or connected with this inspection.
Commision(s)        i                                c lnspecto    gnatur*''-"
e                                                  National Board, State, Province, and Endorsements Date              5--
 
Form NIS-2 Owner's Report, for Repair/Replacement Activities As required by the provisions of the ASME Code Section XI                                                          Work Order Numbe                Sheet 01742798 - 12                        Pagel1 of 2
: 1. owner        Duke Power Company                                            2. Plant    Oconee Nuclear Station                                    Unit 526 South Church Street                                                  7800 Rochestor Hwy Date  5/6/2008 Charlotte, NC 28201-10.06                                                Seneca, SC 28672
: 3. Work Performed By                                                                                                      Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street                                                                                                              Not Applicable Charlotte, NC 28201-1006                                                                                  Expiration Date          Not Applicable
: 4. Identification of Systems, ASME Class Main Steam    ,    ASME Class 2 5.
(a) Applicable Construction Cod USAS B31.1                  1967:    Edition,  No      Addenda No    Code Case (b) Applicable Edition Section XlUtilized For R/R Activity 1998:    Edition,  2000    Addenda (c) Applicable Section XI Codes Cases(s)          None
: 6. Identification of Coimponents Name of Component                        Manufacturer:          Manufacturer          National      Other            Year      Corrected,      ASME Code Serial Number        Board No    identification      Built    Removed or          Stamped Installed        (Yes/No)
(1) Lisega Hydraulic Snubber 1-01A-                Lisega                61314/063              UNK          N/A                UNK      Removed          No 401A-H4347..
Lisega                614883/023              UNK          UTC                UNK      Installed        No 401A-H4347.                                                                                                    1032354 (3) Lisega Hydraulic Snubber 1-01A-                N/A                    N/A                    UNK          N/A                UNK      Removed          No 401A-H4347.
(4) Lisega Hydraulic Snubber 1-01A-                N/A                    N/A                    UNK          UTC 954043        UNK      Installed        No 401A-H4347
: 7. Description of Work Replace leaking Lisega Snubber and worn pivot pin.
: 8. Test Conducted L]    Hydrostatic            LI  Pnuematic              LI  Nominal Operating Pressure            LI  Excempt          [      Other      Visual Pressure                          PSI                                                  Test Temperature                        Deg. F
 
Form NIS-2 Owner's Report for Repair/Replacement Activities As required by the provisions of the ASME Code Section                                                        work Order Numbe                Sheet 01742798 -12            Sh      Page 2 of 2
: 7. Remarks (Applicable Manufactuerrs Data Reports to be attached)
(1) Replace Lisega Snubber due to leaking seals.
(3) Replaced worn pivot pin CERTIFICATION OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl Type Code Symbol Stamp                                                          Not Applicable Certificate of Autherization Number                        Not Applicable                    Expiration Date                Not Applicable Signed                                    s".--    er5,                                      Date            4_/      _      __    __    _
Owner or Owner's Designee, Title CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and State or province of ,                                      and employed by                          HSB CT of                              Hartford, Connecticut                            have inspected the components described in the Owner's Report during the period                  J-z Y'.        e    to            ","--o,                      and state that
                                                                                                                                ,'
to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the inspector nor his employer make any warrenty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind rising from or connected with this inspection.
__        __        _    __    _          Commision(s)          A.C ,e1<1 Inspectors Signature                                              National Board, State, Province, and Endorsements Date      d*.-'
 
I Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section X1 Work Order Number              Sheet 01767674-01                    I of  2
: 1. Owner                                              2. Plant                                                    Unit Duke Power Company                                      Oconee Nuclear Station                                  ONS - 1 526 South Church Street                                7800 Rochester Hwy                              Date Charlotte, NC 28201-1006                                Seneca, SC 29672                                      4/22/2008
: 3. Work Performed by                                                              Type Code Symbol Stamp Not Applicable Duke Power Company                                                      Authorization Number 526 South Church Street                                                                  Not Applicable Charlotte, NC 28201-1006                                                Expiration Date Not Applicable
: 4. Identification of System, ASME Class High Pressure Injection, ASME Class 2 5.
(a) Applicable Construction Code:          USAS 1331.7          19    69  Edition,      No    Addenda,      No        Code Case (b) Applicable Edition Section XI Utilized For R/R Activity      19    98  Edition,      2000    Addenda.
(c) Applicable Section Xl Code Case(s)        None
: 6. Identification of Components Name of              Name of          Manufacturer        National            Other        Year    Corrected,        ASME Component          Manufacturer        Serial Number      Board No.        Identification    Built    Removed,          Code or Installed    Stamped (Yes / No)
IHP Valve        Fisher Controls        4768601            None                None          1971    Corrected          NO
: 7. Description of Work During PM of valve I HP-31 Maintenance found the valve plug eroded
-Iw b
: 8. Test Conducted D  Hydrostatic    F  Pneumatic    E] Nominal Operating Pressure    E] Exempt      Z Other  visual Pressure                PSI              Test Temperature                  OF
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number                  Sheet 01767674-01                      2 of    2
: 9. Remarks (Applicable Manufacturer's Data Reports to be attached) o Valve plug/stem assembly, stock code      86054 1, UTC 0001906415 0
0                                                  CO 0
0 0
o CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.
Type Code Symbol Stamp                                                Not Applicable Certificate of Authorization Number                Not Applicable          Expiration Date              Not Applicable Signedy    W[j,*.*,                              .            (      d      Date                    e Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of                                    and employed by                    HSB CT of                                  Hartford, Connecticut                      - have inspected th9 - components described in this Owner's Report during the period                . Q1 I In          to              '/9" 2-1/od              , and state that to the best of my knowledge and belief, the Owner. has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury* or property damage or a loss of any kind arising from or connected *withthis inspection.
I        " ,nspecjI~torsQCommissions                              ,Vec0          /'-
Insp-ector , Signat~fre                                    National Board, State, Province, and Endorsements Date      _t  a24 0__/
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI F-Work Order Number                Sheet 1761844-03                    I of 2
: 1. Owner                                              2. Plant                                                    Unit Duke Power Company                                      Oconee Nuclear Station                                  ONS - I 526 South Church Street                                7800 Rochester Hwy                                Date Charlotte, NC 28201-1006                                Seneca, SC 29672                                      3/24/2008
: 3. Work Performed by                                                              Type Code Symbol Stamp Not Applicable Duke Power Company                                                      Authorization Number 526 South Church Street                                                                    Not Applicable Charlotte, NC 28201-1006                                                Expiration Date Not Applicable
: 4. Identification of System, ASME Class 1B Reactor Building Spray Pump, ASME Class 2 5.
(a) Applicable Construction Code:          USAS B31.7            19    69  Edition,      No    Addenda,        No      Code Case (b) Applicable Edition Section XI Utilized For RPR Activity        19    98  Edition,'    2000    Addenda.
(c) Applicable Section XI Code Case(s)        None
: 6. Identification of Components Name of              Name of        Manufacturer          National            Other          Year    Corrected,        ASME Component            Manufacturer      Serial Number        Board No.        Identification      Built    Removed,          Code or Installed      Stamped (Yes / No)
NUT, HEX,                                                                      Cat ID#131797 HEAVY HEX                  UNK                UNK              UNK          UTC0001848605        UNK        Installed        YES 7/8"                                                                          UTC0001848605 Washer, Hardened                                                                Cat ID#233021 Steel UNK                LINK              UNK                              UNK        Installed        YES UTC0001848378 Rod, Threaded 7/"UNK                                    LINK            UNK          Cat ID#297414 UC01920              UNK        Installed        YES 7/8"                                                                          UTC0001899220 Rod, Threaded              UNK                UNK              UNK          Cat ID#297414      UNK        Installed        YES 7/8"                                                                          UTC0001835838 Washer, Hardened      Ingersoll-Rand          UNK              UNK                              UNK      Removed            NO Steel Rod, Threaded          Ingersoll-Rand          LINK              UNK                              UNK      Removed            NO 7/8" NUT, HEX, HEAVY HEX              Ingersoll-Rand          LINK              LINK                              UNK      Removed            NO 7/8"
: 7. Description of Work The replacement of the bolts on the U1 B RBS Pumps was completed due to the fact that the exising bolts were too short I(less than one thread on each side of nut) and did not provide the proper thread engagement. All other parts were replaced as part of good maintenance practice.
: 8. Test Conducted D  Hydrostatic    1    Pneumatic    L    Nominal Operating Pressure    0 Exempt          Other  VT-2 Visual Pressure                  PSI              Test Temperature                  OF
 
Form NIS*2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI I
Work Order Number                  Sheet 1761844-03                    2 of    2
: 9. Remarks (Applicable Manufacturer's Data Reports to be attached) 0 0
0
&sect; CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section X1.
Type Code Symbol Stamp                                                    Not Applicable Certificate of Authorization Number                Not Applicable              Expiration Date              Not Applicable Signed                O                                ,Associate Engineer    Date                    3/24/2008 Oyer or Owner's Des    ee Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of .A)6,.er.-Lv eLA.z,,u,                and employed by                    HSB CT of                                Hartford, Connecticut                              have inspected the components described in this Owner's Report during the period                  Z -/V-,o            to        S"-    -'                .' , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for, any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
Commissions        /    ,O/        ,',"
                  "inspector's Signature                                        National Board, State, Province, and Endorsements Date      ,    5- 0 8
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASMvE Code Section XI Work Order Number              Sheet I
1665286                    1 of 2
: 1. Owner                                              2. Plant                                                  Unit Duke Power Company                                    Oconee Nuclear Station                                ONS - 1 526 South Church Street                                7800 Rochester Hwy                              Date Charlotte, NC 28201-1006                              Seneca, SC 29672                                      6/4/2008
: 3. Work Performed by                                                            Type Code Symbol Stamp Not Applicable Duke Power Company                                                    Authorization Number 526 South Church Street                                                                  Not Applicable Charlotte, NC 28201-1006                                              Expiration Date
              /                                                                                    Not Applicable
: 4. Identification of System, ASME Class Low Pressure Injection, ASME Class 2 5.
(a) Applicable Construction Code:          USAS B31.7            19  69  Edition,      No      Addenda,              Code Case (b) Applicable Edition Section XI Utilized For R/R Activity      19  98  Edition,      2000    Addenda.
(c) Applicable Section XI Code Case(s)
: 6. Identification of Components Name of              Name of          Manufacturer        National            Other          Year    Corrected,      ASME Component            Manufacturer      Serial Number      Board No.      Identification      Built    Removed,        Code or Installed    Stamped (Yes / No)
Hanger 2-53B            DPCo.              N/A              N/A                N/A          UNK      Corrected        NO 435B-DE016
: 7. Description of Work Replaced damaged pipe clamp for 10" pipe.
: 8. Test Conducted D Hydrostatic      0  Pneumatic    D Nominal Operating Pressure    Z Exempt          MlOther Pressure                PSI              Test Temperature                  OF
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number                    Sheet I              1665286                    2of 2
: 9. Remarks (Applicable Manufacturer's Data Reports to be attached) o  10" Pipe Clamp, double bolt, Carbon Steel. UTC# 1822444 0
0 0
0 0
0 0
CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.
Type Code Symbol Stamp                                                        Not Applicable Certificate of Authorization Number                    Not Applicable              Expiration Date              Not Applicable Signed          ci.....-..-'".                            Aaron Best, Engineer    Date                      6/4/2008 Owner or Owner' D~signee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of xJ/,er,'                    ,,__,4        and employed by                      HSB CT of                                    Hartford, Connecticut                                have inspected the components described in this Owner's Report during the period                        .o-. /-o 7        to        7- 7-0 *                      , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
______________________                                  Commissions                  AV4;,_
                      -Inspector's Signature                                          National Board, State, Province, and Endorsements Date        7 03
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASMIE Code Section XI U--
Work Order Number                Sheet 1805887                      I of 2
: 1. Owner                                              2. Plant                                                    Unit Duke Power Company                                    Oconee Nuclear Station                                  ONS - 1 526 South Church Street                              7800 Rochester Hwy                                Date Charlotte, NC 28201-1006                              Seneca, SC 29672                                      5/21/2008
: 3. Work Performed by                                                            Type Code Symbol Stamp Not Applicable Duke Power Company                                                    Authorization Number 526 South Church Street                                                                Not Applicable Charlotte, NC 28201-1006                                              Expiration Date I -.                                                                    FNot                    Applicable
: 4. Identification of System, ASME Class Low Pressure Service Water, ASME Class 2 5.
(a) Applicable Constr,,uction Code:        USAS B31.7            19  69  Edition,      No    Addenda,                Code Case (b) Applicable EditiontSection Xl Utilized For R/R Activity      19    98  Edition,      2000    Addenda.
(c) Applicable Section Xl Code Case(s)
: 6. Identification of Components Name of              Name of        Manufacturer        National          Other          Year      Corrected,        ASME Component            Manufacturer      Serial Number      Board No.      Identification      Built    Removed,          Code or Installed    Stamped (Yes / No)
Piping (1)                  DPCo                None            None                None        2008      Corrected          NO
: 7. Description of Work Removed 1A1 RCP.Motor Cooler flanges and replaced with new flanges in a 2 hole configuration.
: 8. Test Conducted D FHydrostatic    D Pneumatic      Z Nominal Operating Pressure    1:1 Exempt      D  Other Pressure                PSI              Test Temperature                  OF
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number                  Sheet 1            1805887                      2 of 2
: 9. Remarks (Applicable Manufacturer's Data Reports to be attached) o Removed 4 flanges and replaced with new            flanges in a 2 hole configuration. 3", 1501b, Sch 40, SS, ASME SA182 F304 0
0 0
0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.
Type Code Symbol Stamp                                                            Not Applicable Certificate of Authorization Numbe                        Not Applicable                Expiration Date              Not Applicable Signed                                                        Aaron Best, Engineer      Date                      5/21/2008 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of ,Vo,7,                                          and employed by                    HSB CT of                                      Hartford, Connecticut                                  have inspected the components described in this Owner's Report during the period                        y  -/7-06'              to        d--                          , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
_________________________                                    Commissions    ,/            V/',.
Inspector's Signature                                              National Board, State, Province, and Endorsements Date      &" -o
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section Xl Work Order Number              Sheet 1736975                    1 of 2
: 1. Owner                                                  2. Plant                                                  Unit Duke Power Company                                        Oconee Nuclear Station                                ONS - 1 526 South Church Street                                    7800 Rochester Hwy                              Date Charlotte, NC 28201-1006                                  Seneca, SC 29672                                    6/5/2008
: 3. Work Performed by                                                                Type Code Symbol Stamp Not Applicable Duke Power Company                                                        Authorization Number 526 South Church Street                                                                    Not Applicable Charlotte, NC 2820 1-1006                                                Expiration Date Not Applicable
: 4. Identification of System, ASME Class High Pressure Injection, ASME Class 2 5.
(a) Applicable Construction Code:              USAS B31.7            19    69  Edition,        No    Addenda,      No      Code Case (b) Applicable Edition Section Xl Utilized For R/R Activity          19    98  Edition,      2000  Addenda.
(c) Applicable Section XI Code Case(s)            None
: 6. Identification of Components Name of                Name of          Manufacturer          National            Other        Year      Corrected,      ASME Component          Manufacturer          Serial Number        Board No.      Identification    Built    Removed,        Code or Installed    Stamped (Yes / No)
.I none              none-(1) 1 HP VA(2 0242    /"piigD4 uLnk                unk              unk                unk          unk      Removed          NO (2) 1 1/2"  piping            DPCo                none              none none          unk      Removed          NO
: 7. Description of Work A 1 1/2" stop-check valve (with reducing inserts) was replace with a 1" swing check valve.
m VF 8. Test Conducted D Hydrostatic              Pneumatic        Nominal Operating Pressure    f7 Exempt        E Other Pressure                  PSI              Test Temperature    _F
 
Fdrm NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number                    Sheet 1736975                      2  of  2 1                                      I
: 9. Remarks (Applicable Manufacturer's Data Reports to be attached) 0 A 1 1/2" stop-check valve (with reducing inserts) was replace with a I" swing check valve.
0 0
0 0
0 0
0 0
CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.
Type Code Symbol Stamp                                                    Not Applicable Certificate of Authorization Number                    Not Applicable            Expiration Date                Not Applicable Signed ja*.          1.    &                Tct.*cpL_ SP~ErAt.\*    1Sj        Date    _        _    _0,_&/_"
Owner or Owner's Designee, Title                                                I                                I CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of f                      o              and employed by                      HSB CT of                                  Hartford, Connecticut                              have inspected the components described in this Owner's Report during the period                        6/,7/0o '      to        4/,/!&#xfd; o8                      , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
Commissions ,OC/V,"          A,,,,c-
        ~    c  to    r's    Sign at~re                                        National Board, National  Board, State, State, Province, Province, and and Endorsements Endorsements Date        4-23-o8
 
Form NIS-2 Owner's Reporf for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI q
Work Order Number                Sheet 01787972                      1 of 2
: 1. Owner                                              2. Plant                                                      Unit Duke Power Company                                      Oconee Nuclear Station                                  ONS - 1 526 South Church Street                                7800 Rochester Hwy                                Date Charlotte, NC 28201-1006                                Seneca, SC 29672                                        5/10/2008
: 3. Work Performed by                                                                Type Code Symbol Stamp Not Applicable Duke Power Company                                                        Authorization Number 526 South Church Street                                                                    Not Applicable Charlotte, NC 28201-1006                                                Expiration Date Not Applicable
: 4. Identification of System, ASME Class Low Pressure Service Water (LPSW), ASME Class 2 5.
(a) Applicable Construction Code:            USAS B31.1            19    69    Edition,      No      Addenda,      No      Code Case (b) Applicable Edition Section XI Utilized For R/R Activity        19    98    Edition,      2000    Addenda.
(c) Applicable Section Xl Code Case(s)          None
: 6. Identification of Components Name of              Name of          Manufacturer        National            Other          Year      Corrected,        ASME Component          Manufacturer        Serial Number      Board No.        Identification      Built      Removed,          Code or Installed    Stamped (Yes I No) 4" 1B2 supply /              NA                  NA                NA                  NA            NA        Corrected          NO return piping        I                  IIIII t                  4                  4                                      4        4 4                  4                  4                4                    4        4              4-4                  4                  4                4                    4        4              4-4                  4                  4                4                    4        4              4-
: 7. Description of Work Due to corrosion concerns, replace carbon steel (CS), 1 inch diameter schedule 40 (Sch 80 past the valve due threaded pipe caps) vent/drain lines with stainless steel (SS) piping. The 1/4" ILPS-IV- 112 insturment pipe and valve were replaced with a 1/2" pipe and valve. In addition, portions of the 4" supply/return pipe were replaced with SS during 1EOC24.
: 8. Test Conducted D-- Hydrostatic    LII  Pneumatic    L--Nominal Operating Pressure          Exempt    N  Other +4,-,    -
Pressure                PSI              Test Temperature                  0 7-ff l4e,,            .        A 7 77:;
 
. 1.
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI:
Type Code Symbol Stamp                                                Not Applicable Certificate of Authorization Number                Not Applicable          Expiration Date              Not Applicable Signed                              Gear.A-nitut, Principal Engineer      Date                      5/10/2008 1                        Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of                                    and employed by                    HSB CT of                                Hartford, Connecticut                          have inspected the components described in this Owner's Report during the period                5//'/o/            to      ___'/____.le/'_          _    , and state that to the best of my knowledge and belief, the O~kner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
A9 8          nCt*            tt                    Commissions        ,//C,t/6 92A-nspector's Signature                                      National Board, State, Province, and Endorsements Date              11___________0
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number              Sheet 1753189                    I of 2
: 1. Owner                                              2. Plant                                                    Unit Duke Power Company                                      Oconee Nuclear Station                                  ONS-    1 526 South Church Street                                7800 Rochester Hwy                              Date Charlotte, NC 28201-1006                                Seneca, SC 29672                                      5/24/2008
: 3. Work Performed by                                                              Type Code Symbol Stamp Not Applicable Duke Power Company                                                      Authorization Number 526 South Church Street                                                                    Not Applicable Charlotte, NC 28201-1006                                                Expiration Date Not Applicable
: 4. Identification of System, ASME Class Vents, React Building Components, ASME Class 2 5.
(a) Applicable Construction Code:          USAS B31.1            19    67  Edition,      No      Addenda,      No        Code Case (b) Applicable Edition Section XI Utilized For R/R Activity      19    98  Edition,      2000    Addenda.
(c) Applicable Section XI Code Case(s)        None
: 6. Identification of Components Name of              Name of          Manufacturer        National            Other          _Year    Corrected,      ASME Component          Manufacturer        Serial Number      Board No.      Identification        Built    Removed,          Code or Installed    Stamped (Yes I No)
(1) S/R 1              DPCo.                None            None                None            Unk      Installed        NO 481A-H6586 (2) S/R 1              DPCo.                None            None                None            Unk      Removed            NO 481 A-H6587 (3)11/2"DPCo.                                  None            None                None            Unk      Installed        NO diameter pipe
: 7. Description of Work S/R 1-57-481A-H6586 was installed incorrectly and was redesigned. S/R 1-57-481A-H6587 was not necessary and was removed. 1 1/2" piping was suspected of cold pull, it was not cold pulled, pipe was rewelded with no additional piping added..        .
m I
: 8. Test Conducted
[ii Hydrostatic    E] Pneumatic      0  Nominal Operating Pressure    -- Exempt        l Other Pressure                PSI              Test Temperature    -
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI I
Work Order Number                  Sheet 1753189                      2 of 2
: 9. Remarks (Applicable Manufacturer's Data Reports to be attached) 0 SiR 1-57-48 1A-146586; added channel UJTC 1046965, added angle UTC 1030165.
0 S/R 1-57-481A-H6587- support was removed.
  ) 1 1/2" piping; additional piping was not added, as pipe had not been cold pulled.
0 0
0 o
0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.
Type Code Symbol Stamp                                                  Not Applicable Certificate of Authorization Number                Not Applicable              Expiration Date              Not Applicable Signed      cak "                                  t                          Date Owner or Owner's Designee, Title Q, CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of          ,Uce47.' Z*_.'e*,*_.A        and employed by                    HSB CT of                                Hartford, Connecticut                              have inspected the components described in this Owner's Report during the period -              f-Z-. -7              to      . -* z r-. Y,                  , and state that to the best of myoknowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning__the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this-inspection.
Commissions      AIC//        tj/AZ,
              - " n.-spectore'Signature                                          National Board, State, Province, and Endorsements Date        _ _ - -n L_?
 
Form NIS-2 Owner's Report for Repair/Replacement Actiity As required by the provisions of the ASME Code Section XI
                                                                                                      -        V - -
Work Order Number              Sheet 1769175                    1 of 2
: 1. Owner                                              2. Plant                                                  Unit Duke Power Company                                    Oconee Nuclear Station                                ONS - 1 526 South Church Street                                7800 Rochester Hwy                              Date Charlotte, NC 28201-1006                              Seneca, SC 29672                                    5/19/2008
: 3. Work Performed by                                                            Type Code Symbol Stamp Not Applicable Duke Power Company                                                    Authorization Number 526 South Church Street                                                                  Not Applicable Charlotte, NC 28201-1006                                              Expiration Date Not Applicable
: 4. Identification of System, ASME Class Low Pressure Service Water, ASME Class 2 5.
(a) Applicable Construction Code:          USAS B31.7            19  69  Edition,      No    Addenda,              Code Case (b) Applicable Edition Section XI Utilized For R/R Activity      19  98  Edition,      2000    Addenda.
(c) Applicable Section XI Code Case(s)        None
: 6. Identification of Components Name of              Name of        Manufacturer        National            Other        Year    Corrected,        ASME Component            Manufacturer      Serial Number        Board No.      Identification    Built    Removed,          Code or Installed    Stamped (Yes / No)
IB2 RCP Motor Cooler Header              DPCo                N/A              N/A                N/A          UNK      Corrected          NO Piping
: 7. Description of Work 1B2 RCP motor cooler header piping was misaligned and would not fit up without cold springing. The piping was cut and rewelded to achieve proper fit up.
: 8. Test Conducted D  Hydrostatic    [:] Pneumatic        Nominal Operating Pressure    E] Exempt      [ Other Pressure                PSI              Test Temperature                OF
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number                  Sheet I            1769175                      2of 2
: 9. Remarks (Applicable Manufacturer's Data Reports to be attached) 0 0
0 o
0 0
0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.
Type Code Symbol Stamp                                                    Not Applicable Certificate of Authorization Num*r        1  7      Not Applicable              Expiration Date              Not Applicable Signed            .-
* Aaron Best, Engineer    Date      S.- /*-, O&.
Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a Valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of ,                        ,              and employed by                    HSB CT of                                Hartford, Connecticut                                have inspected the components described in this Owner's Report during the period                        g- o6' 0        to      C5--e o6                  , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
    "_________________________                              Commissions Al        /*/.',,        ,      .
at u                      *-Ig
                                                      .re                          National Board, State, Province, and Endorsements Date          &- t 9,Y"
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI I
Work Order Number              Sheet 1738412                    I of 2
: 1. Owner                                              2. Plant                                                    Unit Duke Power Company                                    Oconee Nuclear Station                                  ONS - 1 526 South Church Street                                7800 Rochester Hwy                              Date Charlotte, NC 28201-1006                              Seneca, SC 29672                                      4/29/2008
: 3. Work Performed by                                                              Type Code Symbol Stamp Not Applicable.
Duke Power Company                                                      Authorization Number 526 South Church Street                                                                    Not Applicable Charlotte, NC 28201-1006                                                Expiration Date Not Applicable
: 4. Identification of System, ASME Class Low Pressure Service Water, ASME Class 2 5.
(a) Applicable Construction Code:            USAS B31.1          19    67  Edition,      No      Addenda,      No      Code Case (b) Applicable Edition Section Xl Utilized For RIR Activity      19    98  Edition,      2000    Addenda.
(c) Applicable Section Xl Code Case(s)        None
: 6. Identification of Components Name of              Name of          Manufacturer        National            IOther          Year    Corrected,      ASME Component          Manufacturer      Serial Number      Board No.        Identification      Built    Removed,        Code or Installed    Stamped (Yes / No)
                                        &#xb6;                  1                                    t        I              I
.1LPSW-879                Contromatics          UNK              UNK                  none          UNK        Removed          NO 1LPSW-879                    Weir            1-53686-B          None          UTC# 1902177        UNK        Installed      YES (1) Bolting on              UNK                None            None                None          UNK        Installed        NO flanges
: 7. Description of Work OE 101571 - replaced 1 valve. Replaced valve flange bolting.
: 8. Test Conducted Hydrostatic    [: Pneumatic    0  Nominal Operating Pressure    0    Exempt    D  Other Pressure  _            PSI              Test Temperature    '              OF
 
  'I Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number                    Sheet 1738412                      2 of    2 1
: 9. Remarks (Applicable Manufacturer's Data Reports to be attached) 0 Replaced (8) 3/4" studs and (16) 3/4" nuts on 6" valve ILPSW-879.
0 0
0 0
0 0
CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.
Type Code Symbol Stamp                                                      Not Applicable Certificate of Authorization Number                  Not Applicable              Expiration Date              Not Applicable Signed      //e*,-                                            I.                  Date        5f(L_/og Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of A/ozr 6-74'                              and employed by                      HSB CT of                                  Hartford, Connecticut                              have inspected the components described in this Owner's Report during the period                        -  68,..z.      to          s-- a- o6                  , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
Commissions        ,1,C1 .,1o/,gdC,_
Dae - petor's Signature                                          National Board, State, Province, and Endorsements Date        S___    _8  __08      _
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number                Sheet I of 2
                                                              ~,l, /""Y~                              1733887
: 1. Owner                                                  2. Plant                                                    Unit Duke Power Company                                          Oconee Nuclear Station                                  ONS - 1 526 South Church Street                                    7800 Rochester Hwy                                Date Charlotte, NC 28201-1006                                    Seneca, SC 29672                                      12/15/2007
: 3. Work Performed by                                                                  Type Code Symbol Stamp Not Applicable Duke Power Company                                                          Authorization Number 526 South Church Street                                                                        Not Applicable Charlotte, NC 28201-1006                                                    Expiration Date Not Applicable
: 4. Identification of System, ASME Class.
Building Spray, ASME Class 2 5,
(a) Applicable Construction Code:              USAS B31.7            19    69  Edition,        No    Addenda,      No      Code Case (b) Applicable Edition Section XI Utilized For R/R Activity            19    98  Edition,      2000    Addenda.,
(c) Applicable Section Xl Code Case(s)            None 6, Identification of Components Name of              Name of            Manufacturer          National              Other        Year      Corrected,        ASME Component          Manufacturer          Serial Number        Board No.        Identification      Built    Removed,          Code or Installed    Stamped (Yes / No)
V Valve IBS-26                Velan                  072017            None          UTC# 1898801        2007      Installed        YES (I) Piping                  Dpco                  None              None                None          2007      Installed        NO (2) S/R 1-54A-439AH5815Dpco                                      None              None                None          2007      Installed        NO
: 7. Description of Work OD 10-1489 installed new Building Spray emergency connection valve and new QA-                        hanger.
nU 8; Test Conducted D-Hydrostatic EjPneumatic                    Nominal Operating Pressure    ElExempt D-]Other Pressure  _______PSI                          Test Temperature    _______      F
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number                    Sheet 1733887                      2 of    2
: 9. Remarks (Applicable Manufacturer's Data Reports to be attached) o  New 4" Sch 40 Pipe SS (UTC#1004295) (Cat Id. 149541). New 4 on 8 Weldolet SS (UTC#1892993) (Cat Id. 857854). New 4 45 Deg. Sch 40 Elbow SS (UTC#980212) (Cat Id. 79582). New 4" Sch 160 Pipe SS (UTC#1891702) (Cat Id. 149465).
@ New Expansion Anchors (UTC#1082683) (Cat Id. 579437). New 3/4" Plate CS (UTC#1821911) (Cat Id. 151085). New 4" Structural Square Tube (UTC#1846795) (Cat Id. 222052). New 3/4" Flat Bar (UTC#1067874) (Cat Id. 441538).
0 0
0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.
Type Code Symbol Stamp'                                                            Not Applicable Certificate of Authorization Number                        Not Applicable                Expiration Date              Not Applicable Signed 12,,; 14Aj/CQ4YC; JJB4P                                /Technical Specialist 11  Date                      12/15/2007 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Ajok7-,'                  t6 ,xroz.tto          and employed by                    HSB CT of                                      Hartford, Connecticut                                  have inspected the components described in this Owner's Report during the period                        S--/7-0 7              to        /,2 -./7-, 7                  , and state that to the best of my knowledge* and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
_________________________                                    Commissions      A-/        /Vit1/4Y1L Inspector's Signature                                              National Board, State, Province, and Endorsements Date      /2-/7 Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI                                                                                        I Work Order Number                  Sheet 1        1654354                        1 of 2
  -5                                                        I
: 1. Owner                                              2. Plant                                                        Unit Duke Power Company                                      Oconee Nuclear Station                                      ONS-      1 526 South Church Street                                7800 Rochester Hwy                                    Date Charlotte, NC 28201-1006                                Seneca, SC 29672                                          4/28/2008
: 3. Work Performed by                                                                Type Code Symbol Stamp Not Applicable Duke Power Company                                                        Authorization Number 526 South Church Street                                                                        Not Applicable Charlotte, NC 28201-1006                                                  Expiration Date Not Applicable
: 4. Identification of System, ASME Class Low Pressure Injection - Low Pressure Portion, ASME Class 2 "5.
(a) Applicable Construction Code:          USAS B31.7            19    69    Edition,      No        Addenda,      No      Code Case (b) Applicable Edition Section Xl Utilized For R/R Activity        19    98    Edition,      2000      Addenda.
(c) Applicable Section XI Code Case(s)        None
: 6. Identification of Components Name of              Name of        Manufacturer          National              Other            Year      Corrected,        ASME Component          Manufacturer      Serial Number        Board No.        Identification        Built      Removed,          Code or Installed    Stamped (Yes / No)
: 4.                  I                  +                I                      I        4.                4.
Hanger 1-53B                                    DEC                None              None                  None            2008      Corrected          NO 0-444-Hl
: 4.                  I                  +                I-                    I-        *I*              4.
: 4.                  *                  *4                4.                    *0*      4.                .4
: 7. Description of Work ISI visual inspection found several discrepancies between drawing and actual install hanger, broke tack weld, incorrect weld configuration, incorrect cold load setting, etc.
-    b
: 8. Test Conducted D Hydrostatic      E] Pneumatic    E--Nominal Operating Pressure        v Exempt        E-  Other Pressure                PSI                Test Temperature                      OF
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI I
Work Order Number                  Sheet 1654354                      2 of    2
: 9. Remarks (Applicable Manufacturer's Data Reports to be attached) 0 0
0 0
0 0
0 0
CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.
Type Code Symbol Stamp                                                Not Applicable Certificate of Authorization Number                Not Applicable            Expiration Date            Not Applicable Signed                  ,                                        Engineer  Date                      4/28/2008 Owner or Owneregltnee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of .t/e*r/ Z,              ,,g        and employed by                    HSB CT of                                  Hartford, Connecticut                        have inspected the components described in this Owner's Report during the period              /- ZS- C8            to      7-/15-- c 6'                  , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken. corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
Commissions  ,tIC/-'*''-/,d-T-n-"'stor'sS-ggnature                                    National Board, State, Province, and Endorsements Date
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI                                                      p Work Order Number              Sheet
                                                                                    .01610141, 01668348                1 of 7
: 1. Owner                                              2. Plant                                                  Unit Duke Power Company                                      Oconee Nuclear Station                                ONS - 1 526 South Church Street                                7800 Rochester Hwy                              Date Charlotte, NC 28201-1006                              Seneca, SC 29672                                    1/16/2007
: 3. Work Performed by                                                            Type Code Symbol Stamp Not Applicable Duke Power Company                                                    Authorization Number 526 South Church Street                                                                  Not Applicable Charlotte, NC 28201-1006                                              Expiration Date Not Applicable ASME Class
: 4. Identification of System, Condensate & Emergency Feedwater, ASME Class 3 5.
(a) Applicable Construction Code:          USAS B31.1          19    67  Edition,      No    Addenda,      No      Code Case (b) Applicable Edition Section XI Utilized For R/R Activity      19  98  Edition,      2000    Addenda.
(c) Applicable Section X1 Code Case(s)        None
: 6. Identification of Components Name of              Name of        Manufacturer        National            Other        Year      Corrected,      ASME Component          Manufacturer      Serial Number      Board No.      Identification    Built    Removed,        Code or Installed    Stamped (Yes / No)
Valve 1C-152          Allis-Chalmers          UNK              UNK                None          UNK        Removed          NO Valve I C-1 53        Allis-Chalmers          UNK              UNK                None          UNK        Removed          NO Valve 1C-898              Flowserve          E602T-1-3          2918          UTC 1052542        2002      Installed      YES Valve IC-899            Flowserve /          AU323              1135        UTC 1057564        2003      Installed      YES Valtek Valve lC-902              Enertech            11233            None          UTC 1064520        2003      Installed      YES Valve 1C-903                Crane              D1062              26          UTC 1056496        2003      Installed      YES Valve IC-904                Crane              D1067              30          UTC 1056500        2003      Installed      YES Valve IC-906                Crane              Dl117              22          UTC 1063819        2003      Installed      YES Valve 1C-907                Crane              Di 120              24          UTC 1063821        2003      Installed      YES
: 7. Description of Work NSM ON-1 3098 Part AMI installed &/or modified piping & valves to provide automatic isolation and single failure protection to the Upper Surge Tank (UST), the safety grade source of water to the Emergency Feedwater (EFW) Pumps, to ensure that non-safety pathways are isolated. In addition, the EFW pump recirculation pathway supports were upgraded and piping welds will be upgraded to seismic design to ensure the UST inventory is seismically protected.
: 8. Test Conducted Hydrostatic [: Pneumatic Z Nominal Operating Pressure            LI  Exempt    [: Other Pressure                PSI              Test Temperature                  OF
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Sheet Work Order rNumber 016 101 41, 01668348                2 of 7
: 1. Owner                                              2. Plant                                                  Unit Duke Power Company                                    Oconee Nuclear Station                                ONS - 1 526 South Church Street                              7800 Rochester Hwy                              Date Charlotte, NC 28201-1006                              Seneca, SC 29672                                    1/16/2007
: 3. Work Performed by                                                            Type Code Symbol Stamp Not Applicable Duke Power Company                                                    Authorization Number 526 South Church Street                                                                Not Applicable Charlotte, NC 28201-1006                                              Expiration Date Not Applicable
: 4. Identification of System, ASME Class Condensate & Emergency Feedwater, ASME Class 3 5.
(a) Applicable Construction Code:          USAS B31.1          19  67  Edition,      .. No  Addenda,      No      Code Case (b) Applicable Edition Section Xl Utilized For R/R Activity      19  98  Edition,        2000  Addenda.
(c) Applicable Section Xl Code Case(s)        None
: 6. Identification of Components Name of            Name of          Manufacturer        National          Other          Year    Corrected,        ASME Component        Manufacturer        Serial Number        Board No.      Identification      Built    Removed,            Code or Installed      Stamped (Yes I No)
Valve IC-908        Flowserve            E602T-1-2            2917        LUTC 1052541        2002      Installed        YES Valve 1C-912          Enertech              11234              None        UTC 1064521        2003      Installed        YES
'Valve 1FDW-            Neles-92                  JaNiesu                UNK                UNK              LrNK
* UNK 92                  Jamesbury                                                                            Removed            NO Valve lFDW-            Velan              032053              N/A          UTC 1060880        2003      Installed        YES 92 (1) Piping            DPCo.                None              None            None            2006      Installed          NO S/R 1-07A          DPCo.                None              None            None            2006      Installed        NO 0-400A-H39 S/R 1-07A-400B-D09              DPCo.                None              None            None            2006      Installed        NO 400B-DE049 S/R 1-03A          DPCo.                None              None            None            2006 0-400B-H 113                                                                                              Installed,        NO S/R 1-03A        1-03AH1          DPCo.                None              None            None            2006 0-400B-H 114                                                                                              Installed          NO S/R 1-03A        1-03A          DPCo.                None              None            None            2006 0-400B-HI22                                                                                                Installed        NO
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number              Sheet 01610141, 01668348                3 of 7
: 1. Owner                                              2. Plant                                                Unit Duke Power Company                                    Oconee Nuclear Station                              ONS - 1 526 South Church Street                              7800 Rochester Hwy                            Date Charlotte, NC 28201-1006                              Seneca, SC 29672                                    1/16/2007
: 3. Work Performed by                                                          Type Code Symbol Stamp Not Applicable Duke Power Company                                                  Authorization Number 526 South Church Street                                                                Not Applicable Charlotte, NC 28201-1006                                            Expiration Date Not Applicable
: 4. Identification of System, ASME Class Condensate & Emergency Feedwater, ASME Class 3 5.
(a) Applicable Construction Code:          USAS B31.1          19  67  Edition,      No      Addenda,      No      Code Case (b) Applicable Edition Section XI Utilized For R/R Activity      19  98  Edition,      2000    Addenda.
(c) Applicable Section Xl Code Case(s)        None
: 6. Identification of Components Name of            Name of          Manufacturer        National          Other          Year    Corrected,        ASME Component          Manufacturer      Serial Number        Board No. Identification      Built    Removed,          Code or Installed      Stamped (Yes I No)
S/R03A      1-03A-l-DPCo.              None              None            None          2006      Installed 0-400A-H204                                                                                                                NO S/R 1-03A-              DPCo.              None              None            None            2006      Installed        NO 400B-H4398 S/R  1-07A-400B1-07A-              DPCo.              None              None            None            2006      Installed        NO 400B -H4400 S/R 1-07A-400B-H4401              DPCo.              None              None            None            2006      Installed        NO SIR 1-07A-              DPCo.              None              None            None            2006      Installed        NO 400B-H4402 S/R 1-07A-400B SIR  -H4402 1-07A-400B1-07A-              DPCo.              None              None            None            2006      Installed        NO 400B1-07A-              DPCo.              None              None            None            2006      Installed        NO SIR 1-07A-400B-H4404 400B-H4405 400B1-07                DPCo.              None              None            None            2006      Installed        NO S/R l-07A-SIR  1-07A-400WH4407              DPCo.              None              None            None            2006      Installed        NO 400B1-07                DPCo.              None              None            None            2006 140013-H44097                                                                                              Installed        NO 40SB -H440 S/R 1-07A-              DPCo.              None              None            None            2006      Installed        NO
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI) 0                                                                Workrder    Number              Sheet 1  01610141,01668348                    4 of 7
: 1. Owner                                              2. Plant                                                  Unit Duke Power Company                                    Oconee Nuclear Station                                ONS - 1 526 South Church Street                              7800 Rochester Hwy                              Date Charlotte, NC 28201-1006                              Seneca, SC 29672                                    1/16/2007
: 3. Work Performed by                                                          Type Code Symbol Stamp Not Applicable Duke Power Company                                                  Authorization Number 526 South Church Street                                                                Not Applicable Charlotte, NC 28201-1006                                            Expiration Date Not Applicable
: 4. Identification of System, ASME Class Condensate & Emergency Feedwater, ASME Class 3 5.
(a) Applicable Construction Code:          USAS B31.i          19  67  Edition,      No      Addenda,      No      Code Case (b) Applicable Edition Section XI Utilized For R/R Activity      19  98  Edition,      2000    Addenda.
(c) Applicable Section XI Code Case(s)        None
: 6. Identification of Components Name of            Name of          Manufacturer        National          Other          Year    Corrected,        ASME Component          Manufacturer      Serial Number        Board No. Identification      Built    Removed,          Code or Installed      Stamped (Yes / No)
S/R  1-07A-40B410                  DPCo.              None              None            None            2006        Installed        NO 400B-H4410 S/R 1-07A-DPCo.              None              None            None            2006      Installed          NO 402A-H4412 S/R 1-07A-DPCo.              None              None            None            2006      Installed          NO 402A-H4416 402A-H4415 402A1-07A-              DPCo.              None.              None            None            2006      Installed          NO S02A1-07A-              DPCo.              None              None            None            2006 SIR 1-07A-                                                                                                Installed          NO 402A-H4417 402A-H4417 S/R 1-07A-400B1-07A-              DPCo.              None              None            None            2006 400B1-07A-              DPCo.              None              None            None            2006      Installed Installed          NO NO 400B-H4420 S/R 1-07A-S00B1-07A-              DPCo.              None              None            None            2006 402A-H4427                                                                                                Installed          NO S/R 1-07A-402A1-07A-              DPCo.              None              None            None            2006      Installed          NO S/R 1-07A-402A-H4438              DPCo.              None              None            None            2006      Installed          NO
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number              Sheet 01610141, 01668348                5 of 7
: 1. Owner                                            2. Plant                                                  Unit Duke Power Company                                  Oconee Nuclear Station                                ONS - 1 526 South Church Street                            7800 Rochester Hwy                              Date Charlotte, NC 28201-1006                            Seneca, SC 29672                                    1/16/2007
: 3. Work Performed by                                                          Type Code Symbol Stamp Not Applicable Duke Power Company                                                  Authorization Number 526 South Church Street                                                              Not Applicable Charlotte, NC 28201-1006                                            Expiration Date Not Applicable
: 4. Identification of System, ASME Class Condensate & Emergency Feedwater, ASME Class 3 5.
(a) Applicable Construction Code:            USAS B31.1        19  67  Edition,      No      Addenda,      No      Code Case (b) Applicable Edition Section XAUtilized For R/R Activity      19  98  Edition,      2000    Addenda.
(c) Applicable Section XACode Case(s)          None
: 6. Identification of Components Name of          Name of          Manufacturer      National          Other          Year    Corrected,        ASME Component          Manufacturer        Serial Number      Board No.      Identification      Built    Removed,            Code or Installed      Stamped
                                                                                                    -                    (Yes / No)
S/R  ]-07A-402A1-07A-              DPCo.              None            None              None          2006      Installed          NO 402A-H4439 S/R 1-03A-None            None              None          2006      Installed          NO 400114442                DPCo.
400B-H4442 S/R 1-03A-400B-H4443 S/R 1-03A-400B1-07A-              DPCo.              None            None              None          2006      Installed          NO 400B1-07A-              DPCo.              None            None              None          2006      Installed          NO S/R 1-07A-400B-SR246 400B1-H4447 400B1-07A                DPCo.              None            None              None          2006      Corrected          NO S/R 1-03A                          DPCo.              None            None              None          2006      Corrected          NO 0-400B-HI74 S/R 1-03A-l-0-400B-HI35              DPCo.              None            None              None          2006      Removed            NO 0400BH 15 S/R 1-03A            DPCo.              None            None              None          2006      Removed            NO S/R 1-03A-400A-AM-                DPCo.              None            None              None          2006      Removed            NO 1601
    -    -    135                    1                                1                    1
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number              Sheet 016'10141, 01668348                6 of 7
: 1. Owner                                              2. Plant                                                Unit Duke Power Company                                    Oconee Nuclear Station                              ONS - 1 526 South Church Street                              7800 Rochester Hwy                            Date Charlotte, NC 28201-1006                              Seneca, SC 29672                                    1/16/2007
: 3. Work Performed by                                                          Type Code Symbol Stamp Not Applicable Duke Power Company                                                  Authorization Number 526 South Church Street                                                                Not Applicable Charlotte, NC 28.201-1006                                            Expiration Date Not Applicable ASME Class
: 4. Identification of System, Condensate & Emergency Feedwater, ASME Class 3 5.
(a) Applicable Construction Code:          USAS B31.1          19  67  Edition,      No      Addenda,      No      Code Case (b) Applicable Edition Section Xl Utilized For R/R Activity      19  98  Edition,      2000    Addenda.
(c) Applicable Section Xl Code Case(s)        None
: 6. Identification of Components Name of            Name of          Manufacturer        National          Other          Year    Corrected,        ASME Component          Manufacturer      Serial Number        Board No. Identification      Built    Removed,            Code or Installed      Stamped (Yes / No)
S/R  1-07A-400B1-07A-              DPCo.              None              None            None          2006      Removed 400B-DE055                                                                                                                  NO S/R 1-07A-              DPCo.              None              None            None            2006      Removed            NO 400B-DE056 S/R  ]-03A  0.4103                DPCo.              None              None            None            2006      Removed 0-400B-HI123                                                                                                                NO SIR 1-07A  400B-TLM-                DPCo.              None              None            None          2006      Removed            NO 2113 S/R 1-07A-400B-TLM-                DPCo.              None              None            None            2006      Removed            NO 2116 SIR  1-07A-402AH4414                DPCo              None              None            None          2006      Corrected          NO (2) Tank IC              DPCo.              None              None            None          2006      Installed          NO TKOOOC
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI I
Work Order Number                  Sheet 01610141, 01668348                  7 of 7
: 9. Remarks (Applicable Manufacturer's Data Reports to be attached) 0 Installed pipina; (4) 30" (8) 20", (6) 8" & (2) 6" flanges; (248) 1-1/8", (224) 1-1/4" & (64) 3/4" nuts and studs.
0  Installed exterior & interior bracing to tank (4 X 4 X 1/2 cross angles, 1/2" stiffner plates, 1/2" gusset plates) 0 0
0 0
0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.
Type Code Symbol Stamp                                                    Not Applicable Certificate of Authorization Number                    Not Applicable            Expiration Date              Not Applicable Signed                                    K, Tor O Wner Owner's4gDCeisge[                                Date    o1(-J/:Z0o Owner or Owner's tesignee, Title p                                                                                                                                            U CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of AJo~e r-.'              ,oz..A          and employed by                    HSB CT of                                    Hartford, Connecticut                              have inspected the components described in this Owner's Report during the period                      &,--                to            -/- o                    , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
___________________________                              Commissions      A/,,4J'L Inspector's Signature                                        National Board, State, Province, and Endorsements Date        s____--    _o_
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number                Sheet 01716586                      I of  2
: 1. Owner                                              2. Plant                                                      Unit Duke Power Company                                    Oconee Nuclear Station                                    ONS - 1 526 South Church Street                                7800 Rochester Hwy                                  Date Charlotte, NC 28201-1006                              Seneca, SC 29672                                        05/01/2008
: 3. Work Performed by                                                              Type Code Symbol Stamp Not Applicable Duke Power Company                                                      Authorization Number 526 South Church Street                                                                    Not Applicable Charlotte, NC 28201-1006                                                Expiration Date Not Applicable
: 4. Identification of System, ASME Class Condensate & Emergency Feedwater, ASME Class 3 5.
(a) Applicable Construction Code:          USAS B3 1.1          19  67    Edition,      No        Addenda,      No      Code Case (b) Applicable Edition Section X1 Utilized For R/R Activity      19  98    Edition,      2000      Addenda.
(c) Applicable Section XI Code Case(s)        None
: 6. Identification of Components Name of              Name of        Manufacturer        National            Other            Year    Corrected,          ASME Component          Manufacturer      Serial Number      Board No.        Identification        Built    Removed,            Code or Installed      Stamped (Yes /No)
Valve I C-903              Crane              D1062              26          UTC 1056496          2003      Removed            YES Valve I C-904              Crane              D1067              30          UTC 1056500          2003      Removed            YES Valve IC-903                Crane              D1065              28          UTC 1056498          2003      Installed          YES Valve I C-904              Crane              D1063              27          UTC 1056497          2003      installed          YES (1) S/R 1-03A            DPCo                None            None                None            UNK      Corrected            NO 0-400A-SR36 (2) S/R 1-03A            DPCo                None              None                None            UNK      Corrected            NO 0-400B-H200 (3) Piping                  DPCo                None              None                None            2008      Corrected            NO i                                                                            . -      .                .-
: 7. Description of Work NSM 13098 Part AMI performed "warranty" work during lEOC24 that included completing repairs & inspections on Condensate & Emergency Feedwater pipe welds & supports and correcting flow orientation of two 20" butterfly valves
: 8. Test Conducted E] Hydrostatic      0  Pneumatic    0  Nominal Operating Pressure E] Exempt          - Other Pressure                PSI              Test Temperature                    OF
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI I
Work Order Number                  Sheet 01716586                      2 of 2
: 9. Remarks (Applicable Manufacturer's Data Reports to be attached) 0 Removed unnecessary 1V X 1" lugs on existing upgraded support.
0 Replaced damaged size "B" sway strut & 5/8 x 6" u-bolt with new sway strut & u-bolt; corrected 1/2" plate configuration.
O Replaced EFW piping & added one 6000# half coupling & one reinforcing collar to correct two 2" branch on 6" run welded joints.
0 0
Owe rOnrsDsgeIW CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.I Type Code Symbol Stamp                                                  Not Applicable Certificate of Authorization Number                  Not Applicable            Expiration Date              Not Applicable Signed        k( &#xfd;Je. 1-')                    Z    IBI-~2(J
                                                            ~pclIStat U
CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of A/o~rerA'        ,v,#,oL,,,3o        and employed by                    HSB CT of                                  Hartford, Connecticut                          have inspected the components described in this Owner's Report during the period                8 - V- a            -to          :r--7 -.0 8                , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected, with this inspection.
Commissions.
Inspector' s Signature                                      National Board, State, Province, and Endorsements Date    __-__"_O,                  _
 
4' Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI p
Work Order Number                  Sheet 1755696                      I of 2
: 1. Owner                                              2. Plant                                                      Unit Duke Power Company                                      Oconee Nuclear Station                                    ONS - I 526 South Church Street                                7800 Rochester Hwy                                Date Charlotte, NC 28201-1006                                Seneca, SC 29672                                        5/23/2008
: 3. Work Performed by                                                            Type Code Symbol Stamp Not Applicable Duke Power Company                                                    Authorization Number 526 South Church Street                                                                    Not Applicable Charlotte, NC 28201-1006                                              Expiration Date:.
                                                                                                        *Not Applicable
: 4. Identification of System, ASME Class Main Steam, ASME Class 3 5.
(a) Applicable Construction Code:          USAS B31.7            19  69  Edition,      No        Addenda,              Code Case (b) Applicable Edition Section XI Utilized For R/R Activity      19  98  Edition,    .2000    (Addenda.
(c) Applicable Section Xl Code Case(s)                                            ,:
: 6. Identification of Components Name of              Name of        Manufacturer        National            Other            Year    Corrected,.      ASME Component            Manufacturer      Serial Number        Board No.      Identification        Built    Removed,          Code or Installed    Stamped (Yes / No)
Piping                      DPCo              None              None                None            2008      Corrected,        NO
: 7. Description of Work Welds 1-MS-0141-1 and I-MS-6142-1 had to have indications ground out and rewelded prior to PWHT.
-U
: 8. Test Conducted D iHydrostatic      F]Pneumatic      E Nominal Operating Pressure      Z Exempt        1: Other Pressure _              PSI              Test Temperature                    OF
 
:      4 Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI
-  U CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.
Type Code Symbol Stamp                                                      Not Applicable Certificate of Authorization Number                Not Applicable                Expiration Date              Not Applicable Signed      , C&#xfd;--*                            *        *Aaron Best, Engineer    Date                      5/23/2008 Owner or Owner's IDeglgnee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of          .LP. L,-.J,9                    and employed by                    HSB CT of                              Hartford, Connecticut                                  have inspected the components described in this Owner's Report during the period                        _._ oil___      to          5-      "-e- '&            , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
Commissions .. )"1,',(.,w,,f                C_
D--n-etor's Signature                                              National Board, State, Province, and Endorsements Date    _  _  _  _  _  _  _  _
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI U
Work Order Number                      Sheet 01768134-01                        I of 2
: 1. Owner                                                      2. Plant                                                              Unit Duke Power Company                                              Oconee Nuclear Station                                        ONS - 1 526 South Church Street                                        7800 Rochester Hwy                                      Date Charlotte, NC 28201-1006                                        Seneca, SC 29672                                              4/25/2008
: 3. Work Performed by                                                                          Type Code Symbol Stamp Not Applicable Duke Power Company                                                              Authorization Number 526 South Church Street                                                                                Not Applicable Charlotte, NC 28201-1006                                                        Expiration Date Not Applicable
: 4. Identification of System, ASME Class High Pressure Injection, ASME Class 3 5.
(a) Applicable Construction Code:                  USAS B31.7                19    69  Edition,          No      Addenda,        No      Code Case (b) Applicable Edition Section XI Utilized For R/R Activity                  19    98  Edition,          2000      Addenda.
(c) Applicable Section XI Code Case(s)                None 6.' Identification of Components, Name of                  Name of          Manufacturer              National              Other              Year      Corrected,            ASME Component              Manufacturer        Serial Number            Board No.          Identification          Built      Removed,              Code or Installed        Stamped (Yes / No) 1HP-7 Valve                        CCI              Unknown                  None                None              1998      Corrected              NO 1~                  1-                    1-                                            4~      +
: 4.                  4.                    4-                  4                        4        +
I.                  4-                    +                    4                        +        +
: 4.                  4                      +                    4                        +        +
                            +                    +                      +                    4                        +        4                    1
________________
: 7. Description of Work I I I
______________      ______________        ______________    ________________
PM of the valve revealed that the spindle was eroded on it's seating surface that interfaces with the seat ring.
Maintenance to replacethe damaged spindle.
____________        _________
- I
: 8. Test Conducted I  Hydrostatic        1 Pneumatic      I    Nominal Operating Pressure        1 Exempt          Z    Other  Visual Pressure                    PSI                  Test Temperature                        OF
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section X1 Work Order Number                  Sheet I
01768134-01                    2 of 2
: 9. Remarks (Applicable Manufacturer's Data Reports to be attached) 0 Spindle, Catalog # 480657, UTC # 0001895438 0
0 0
0 0
0 0
CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.
Type Code Symbol Stamp                                                  Not Applicable Certificate of Authorization Number                Not Applicable            Expiration Date            Not Applicable Signed              "          i &#xfd; 4* ,I-                          ,t4c0/*e                  _________
          //t          Owner or Owner's Designee, Title              I CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of                                      and employed by                    HSB CT of                                  Hartford, Connecticut                            have inspected the components described in this Owner's Report during the period                .,  /                to      *!      --o V                  , and state that to the best of my knowledge and belief, the Owner has performed examitations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
6,t
            "      C                                        Commissions        AvC/ / f/9/*A/J7 Inspector s Signature                                      National Board, State, Province, and Endorsements Date    __    _    _  _  _  _      _
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASMIE Code Section XI Work Order Number                Sheet 01739005-01                      1 of 2
: 1. Owner                                              2. Plant                                                      Unit Duke Power Company                                    Oconee Nuclear Station.                                  ONS - I 526 South Church Street                                7800 Rochester Hwy                                Date Charlotte, NC 28201-1006                              Seneca, SC 29672                                        04-27-08
: 3. Work Performed by                                                              Type Code Symbol Stamp Not Applicable Duke Power Company,                                                      Authorization Number 526 South Church Street                                                                    Not Applicable Charlotte, NC 28201-1006                                                Expiration Date Not Applicable
: 4. Identification of System, ASME Class High Pressure Injection, ASME Class 3 5.
(a) Applicable Construction Code:        ASME Section III        19  89    Edition,      No      Addenda,      No      Code Case (b) Applicable Edition Section XI Utilized For R/R Activity      19  98    Edition,      2000    Addenda.
(c) Applicable Section Xl Code Case(s)
: 6. Identification of Components Name of              Name of        Manufacturer        National              Other          Year    Corrected,      ASME Component            Manufacturer      Serial Number      Board No.        Identification      Built    Removed,        Code or Installed    Stamped (Yes / No)
Control 11HP-65, assembly        Components        227953-010-1          none                N/A          UNK      Removed          NO Inc.
0 1HP-65,                  Control Components        230642-010-3          none                N/A          2005      Installed        NO assembly                    Inc.
4                  1                4                    4      I                I
: 7. Description of Work Valve assembly was installed a preventive maintenance. Assembly contains bonnet (part 600276, s/n: 3) and spindle (part 600277, s/n: 3) that are pressure boundary.
: 8. Test Conducted 0  Hydrostatic    L    Pneumatic    L  Nominal Operating Pressure    Li  Exempt      H Other    F/V Leak Check Pressure                PSI              Test Temperature                    &deg;F O
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number                  Sheet 0                                                                                            01739005-01                      2 of 2
: 9. Remarks (Applicable Manufacturer's Data Reports to be attached) o  Valve assembly, Duke Catalog ID: 514956, serial number: 230642-010-3. UTC No.: 1081331. Assembly contains bonnet (part 600276, s/n: 3) and spindle (part 600277, s/n: 3) that are pressure boundary. Bonnet material: SA-479-316. Spindle material:
SB 637-N07718.
0 0
0 0
0 0
0 SI CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.
Type Code Symbol Stamp                                                    Not Applicable Certificate of Authorization Nu            be /      Not Applicable              Expiration Date              Not Applicable Signed                                                          , Sr. Engineer  Date                    4/27/2008
                        "- Owner or Owrer's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of                                        and employed by                    HSB CT of                                    Hartford, Connecticut                            have inspected the components described in this Owner's Report during the period                S'//,/c a,            to        */,.j/o V                    , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with his inspection.
n)s*pector's Sint**ure                  Commissions          National B      SaePoianEdrmt (I    Inspector's  Signature                                        National Board, State, Province, and Endorsements Date    ______            _____
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI IWork Order Number                Sheet 01739007-01                    I of 2
-                                                                                                                p
: 1. Owner                                              2. Plant                                                    Unit Duke Power Company                                    Oconee Nuclear Station                                  ONS - 1 526 South Church Street                              7800 Rochester Hwy                                Date Charlotte, NC 28201-1006                              Seneca, SC 29672                                      04-27-08
: 3. Work Performed by                                                            Type Code Symbol Stamp Not Applicable Duke Power Company                                                    Authorization Number 526 South Church Street                                                                  Not Applicable Charlotte, NC 28201-1006                                                Expiration Date Not Applicable
: 4. Identification of System, ASME Class High Pressure Injection, ASME Class 3 5.
(a) Applicable Construction Code:        ASME Section III      19  89    Edition,        No    Addenda,      No      Code Case (b) Applicable Edition Section Xl Utilized For R/R Activity      19  98    Edition,      2000    Addenda.
(c) Applicable Section Xl Code Case(s)
: 6. Identification of Components Name of              Name of        Manufacturer        National            Other          Year    Corrected,      ASME Component            Manufacturer      Serial Number      Board No.      Identification      Built    Removed,        Code or Installed  Stamped (Yes / No)
Control 1HP-67, assembly        Components        225245-010-1          none                N/A          UNK        Removed          NO Inc.
0 1HP-67,                  Control Components        230642-010-1          none                N/A          2005      Installed        NO assembly                      Inc.
: 7. Description of Work Valve assembly was installed a preventive maintenance. Assembly contains bonnet (part 600276, s/n: 1) and spindle (part 600277, s/n: 1) that are pressure boundary.
: 8. Test Conducted SHydrostatic    [:] Pneumatic    E] Nominal Operating Pressure  E] Exempt          Other  F/V Leak Check Pressure                PSI            Test Temperature                  OF
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number                  Sheet 01739007-01                      2 of 2
: 9. Remarks (Applicable Manufacturer's Data Reports to be attached) 0 Valve assembly, Duke Catalog ID: 514956, serial number: 230642-010-1. UTC No.: 1080977. Assembly contains bonnet (part 600276, s/n: 1) and spindle (part 600277, s/n: 1) that are pressure boundary. Bonnet material: SA-479-316. Spindle material:
SB 637-N07718.
0 0
0 0
0 0
CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.
Type Code Symbol Stamp                                                  Not Applicable Certificate of Authorization Number                Not Applicable              Expiration Date              Not Applicable Signed                                          .            ,Sr. Engineer    Date                      4/27/2008
                    &#xfd;&#xfd;Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of                                        and employed by                    HSB CT of                                  Hartford, Connecticut                            have inspected the components described in this Owner's Report during the period                  =/,V/o0*j            to        0"!,,_____,_/                , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
P **7Commissions                                                          'Ale/4                      '-
Inspector's Signature                                        National Board, State, Province, and Endorsements Date    ____      __1  _    ____
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASMIE Code Section XI I. --
Work Order Number                Sheet 01739004-01                    I of  2
: 1. Owner                                              2. Plant                                                    Unit Duke Power Company                                    Oconee Nuclear Station                                  ONS - 1 526 South Church Street                                7800 Rochester Hwy                                Date Charlotte, NC 28201-1006                              Seneca, SC 29672                                      04-27-08
: 3. Work Performed by                                                              Type Code Symbol Stamp Not Applicable Duke Power Company                                                      Authorization Number 526 South Church Street                                                                  Not Applicable Charlotte, NC 28201-1006                                                Expiration Date Not Applicable
: 4. Identification of System, ASME Class High Pressure Injection, ASME Class 3 5.
(a) Applicable Construction Code:        ASME Section III        19  89    Edition,      No    Addenda,        No    Code Case (b) Applicable Edition Section Xl Utilized For R/R Activity      19  98    Edition,      2000    Addenda.
(c) Applicable Section Xl Code Case(s)
: 6. Identification of Components Name of              Name of        Manufacturer        National            Other        Year    Corrected,        ASME Component            Manufacturer      Serial Number      Board No.        Identification    Built    Removed,        Code or Installed    Stamped (Yes / No)
Control 1HIP-64, assembly        Components        227953-010-2          none                N/A          UNK      Removed          NO Inc.
0 IIP-64,                  Control assembly                Components        230642-010-2          none                N/A          2005      Installed        NO Inc.
: 7. Description of Work Valve assembly was installed a preventive maintenance. Assembly contains bonnet (part 600276, s/n: 2) and spindle (part 600277, s/n: 2) that are pressure boundary.
: 8. Test Conducted FD Hydrostatic    [1 Pneumatic      1:] Nominal Operating Pressure  n- Exempt          Other  F/V Leak Check Pressure                PSI              Test Temperature                  OF
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number                  Sheet 01739004-01                      2 of 2
: 9. Remarks (Applicable Manufacturer's Data Reports to be attached) o Valve assembly, Duke Catalog ID: 514956, serial number: 230642-010-2. UTC No.: 1081330. Assembly contains bonnet (part 600276, s/n: 2) and spindle (part 600277, s/n: 2) that are pressure boundary. Bonnet material: SA-479-316. Spindle material:
SB 637-N07718.
0 0
o 0
o 0
0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.
Type Code Symbol Stamp                                                      Not Applicable Certificate of Authorization Number                    Not Applicable            Expiration Date              Not Applicable Signed                              -                            , Sr. Engineer    Date                    4/27/2008
                      - Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of                                          and employed by                    HSB CT of                                    Hartford, Connecticut                            have inspected the components described in this Owner's Report during the period                V /1/0 e                to                  *"
R,/,              , and state that to the best of my knowledge and belief, the'Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
    &#xfd;By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
____                  _9__44*_              _,-Commissions                fvC-//4'        ,q6'.Y            "
Inspector's Signa-f're                                          National Board, State, Province, and Endorsements Date/,    ""/
              ,    ,
________
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASMIE Code Section XI
                                                                                                                'U
                                                                                                                  '9 Work Order Number              Sheet 01739001-01                    I of 2
: 1. Owner                                              2. Plant                                                    Unit Duke Power Company                                      Oconee Nuclear Station                                ONS - 1 526 South Church Street                                7800 Rochester Hwy                              Date Charlotte, NC 28201-1006                                Seneca, SC 29672                                      04-27-08
: 3. Work Performed by                                                              Type Code Symbol Stamp Not Applicable Duke Power Company                                                      Authorization Number 526 South Church Street                                                                  Not Applicable Charlotte, NC 28201-1006                                                Expiration Date Not Applicable
: 4. Identification of System, ASME Class High Pressure Injection, ASME Class 3 5.
(a) Applicable Construction Code:        ASME Section III        19  89    Edition,      No    Addenda,      No      Code Case (b) Applicable Edition Section Xl Utilized For R/R Activity      19  98    Edition,      2000    Addenda.,
(c) Applicable Section Xl Code Case(s)
: 6. Identification of Components Name of              Name of        Manufacturer        National            Other          Year    Corrected,      ASME Component            Manufacturer      Serial Number        Board No.        Identification      Built    Removed,        Code or Installed    Stamped (Yes / No)
Control IHP-66, assembly        Components        600538-010-1          none                N/A          UNK        Removed          NO Inc.
0 1HP-66,                  Control assembly                Components        225245-010-1          none                N/A          2003      Installed
* NO Inc.
: 7. Description of Work Valve assembly was installed a preventive maintenance. Assembly contains bonnet (part 635218, s/n: 1) and spindle (part 177488, s/n: 1) that are pressure boundary.
: 8. Test Conducted D  Hydrostatic    1 Pneumatic        I Nominal Operating Pressure    R-I Exempt      E  Other  F/V Leak Check Pressure                PSI              Test Temperature                  OF
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number                  Sheet 01739001-01                      2 of  2
: 9. Remarks (Applicable Manufacturer's Data Reports to be attached) 0 Valve assembly, Duke Catalog ID: 514956, serial number: 225245-010-1. UTC No.: 1066679. Assembly contains bonnet (part 635218, s/n: 1) and spindle (part 177488, s/n: 1) that are pressure boundary. Bonnet material: SA-479-316. Spindle material:
SB 637-N07718.
0 0                                                            -0 0
0 0
0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.
Type Code Symbol Stamp                                                        Not Applicable Certificate of Authorization Number                    Not Applicable              Expiration Date            Not Applicable Signed                                                              ,Sr. Engineer    Date                    4/27/2008 Ower or Owne'r's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or'Province of                                            and employed by                    HSB CT of                                  Hartford, Connecticut                                have inspected the components described in this Owner's Report during the period                  S/Zi f/0 a/              to    5/,,-i/oaF                      , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the i  Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
___          _"      _      _
_W        _&#xfd;_&#xfd; _          _ Commissions      ,V6i'1// b 61    Inspector's Signatur                                            National Board, State, Province, and Endorsements Date    Cl/*4 /0
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number              Sheet 1778277 - 93 & 95                I of 2
: 1. Owner                                              2. Plant                                                  Unit Duke Power Company                                    Oconee Nuclear Station                                  ONS - 1 526 South Church Street                              7800 Rochester Hwy                              Date Charlotte, NC 28201-1006                              Seneca, SC 29672                                      5/21/2008
: 3. Work Performed by                                                            Type Code Symbol Stamp Not Applicable Duke Power Company                                                    Authorization Number 526 South Church Street                                                                Not Applicable Charlotte, NC 28201-1006                                              Expiration Date Not Applicable
: 4. Identification of System, ASME Class Reactor Coolant System, ASME Class 3 5.
(a) Applicable Construction Code:          USAS B31.7          19    69  Edition,      No    Addenda,                Code Case (b) Applicable Edition Section Xl Utilized For R/R Activity      19    98  Edition,      2000    Addenda.
(c) Applicable Section Xl Code Case(s)
: 6. Identification of Components Name of              Name of        Manufacturer        National            Other          Year      Corrected,        ASME Component          Manufacturer      Serial Number      Board No.      Identification    Built    Removed,          Code or Installed    Stamped (Yes / No)
Piping                      DPCo              None            None              None          2008      Installed        NO Bolting (1)                  UNK                None            None              None          UNK        Installed        NO
: 7. Description of Work Reattached piping by welding near 4" to 8" reducer on pressurizer relief vavle discharge piping. Also replaced bolting on flange on 12" section of pipe.
: 8. Test Conducted D Hydrostatic      0 Pneumatic      [2 Nominal Operating Pressure    0 Exempt        D Other Pressure _              PSI              Test Temperature                  OF
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI I
Work Order Number                  Sheet 1778277- 9L-Q_            2 of 2
: 9. Remarks (Applicable Manufacturer's Data Reports to be attached) o  Replaced (20) 1 1/4" Studs SA 193 .GR B7 and (40) heavy hex nuts SA 194 GR 2H 0
0i 0
0 0
0/
CERTIFICATE OF COMPLIANCE I certify that thestatements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.
Type Code Symbol Stamp                                                    Not Applicable Certificate of Authorization Number                Not Applicable              Expiration Date              Not Applicable Signed                                                  Aaron Best, Engineer    Date          S" Z.I-Owner or Owvner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and PressureVessel Inspectors and the State or Province of ,                    ,      ,        and employed by                    HSB CT of                                Hartford, Connecticut                                have inspected the components described in this Owner's Report during the period                            0.e-o
                                                                        '      to        ,5--    .,r                  , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the, ASME Code, Section Xl.
    -By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer.shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
Commissions ,J            '/Z/,*',,"
Inspector's Signature                                          National Board, State, Province, and Endorsements Date              od6
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI 0
Work Order Number              Sheet 01768289-01                    1 of 2 I
: 1. Owner                                              2. Plant                                                    Unit Duke Power Company                                      Oconee Nuclear Station                                ONS - 1 526 South Church Street                                7800 Rochester Hwy                              Date Charlotte, NC 28201-1006                                Seneca, SC 29672                                      4/22/2008
: 3. Work Performed by                                                              Type Code Symbol Stamp Not Applicable Duke Power Company                                                      Authorization Number 526 South Church Street                                                                    Not Applicable Charlotte, NC 28201-1006                                                Expiration Date Not Applicable
: 4. Identification of System, ASME Class p*    Feed Water, ASME Class 3 5.
(a) Applicable Construction Code:          USAS B31.1            19    67  Edition,        No    Addenda,      No      Code Case (b) Applicable Edition Section XI Utilized For R/R Activity        19    98  Edition,      2000    Addenda.
(c) Applicable Section XI Code Case(s)        None
: 6. Identification of Components Name of                Name of        Manufacturer        National            Other          Year    Corrected,      ASME Component            Manufacturer      Serial Number        Board No.        Identification    Built    Removed,        Code or Installed    Stamped (Yes I No)
Valve IFDW-44            Fisher Control      Unknown              None                N/A          1968      Corrected        NO
: 7. Description of Work During valve disassembly the bonnet to body studs and nuts were damaged S  8.Test Conducted D Hydrostatic        [-I Pneumatic    E] Nominal Operating Pressure      1] Exempt      MOther  Visual Pressure                PSI                Test Temperature                  OF
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section Xl Work Order Number                  Sheet 01768289-01                      2 of 2
: 9. Remarks (Applicable Manufacturer's Data Reports to be attached) o  Valve bonnet studs, stock code 297405, UTC 0001089307 0 Valve bonnet nuts, stock code 135634, UTC 0001089938 0
0 0
0 0
0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.
Type Code Symbol Stamp                                                    Not Applicable Certificate of Authorization Number                    Not Applicable          Expiration Date              Not Applicable Signed Xa",                                                                    Date          ____________
("          \( Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of                                        and employed by                      HSB CT of                                    Hartford, Connecticut                          have inspected the components described in this Owner's Report during the period            _    //_ / 0_*_          to          15_/_")-___-/_"            , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
* ______________                          Commissions  A1/C//6                            -
Inspector's Signature                                        National Board, State, Province, and Endorsements Date          /f__        t-_    _  _
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number              Sheet 1778277-72                  1 of 2
: 1. Owner                                              2. Plant                                                  Unit Duke Power Company                                    Oconee Nuclear Station                                ONS - 1 526 South Church Street                                7800 Rochester Hwy                              Date Charlotte, NC 28201-1006                              Seneca, SC 29672                                    6/17/2008
: 3. Work Performed by                                                              Type Code Symbol Stamp Not Applicable Duke Power Company                                                      Authorization Number 526 South Church Street                                                                  Not Applicable Charlotte, NC 28201-1006                                                Expiration Date Not Applicable
: 4. Identification of System, ASME Class Reactor Coolant System, ASME Class 3 5.
(a) Applicable Construction Code:          USAS B31.7            19    69  Edition,      No    Addenda,              Code Case (b) Applicable Edition Section Xl Utilized For R/R Activity      19    98  Edition,      2000    Addenda.
(c) Applicable Section X1 Code Case(s)
: 6. Identification of Components Name of              Name of        Manufacturer        National            Other        Year    Corrected,      ASME Component            Manufacturer      Serial Number      Board No.        Identification      Built    Removed,        Code or Installed    Stamped (Yes / No)
(1)1-57-0-481A-            DPCo.              N/A              N/A                N/A          2008      Corrected        NO H16
: 7. Description of Work Replaced pivot pin on S/R 1-57-0-481A-H16 during reinstallation in support of 1AI RCP Motor Replacement.
- i
: 8. Test Conducted D  Hydrostatic      D Pneumatic      D  Nominal Operating Pressure    E Exempt        D  Other Pressure                PSI              Test Temperature                  OF
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number                  Sheet 1778277-72                    2 of 2
: 9. Remarks (Applicable Manufacturer's Data Reports to be attached) o S/R    Pivot pin, UTC# 1093284 0
0 0
0 0
0 0
CERTIFICATE OF COMPLIANCE I Oertify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.
Type Code Symbol Stamp                                                          Not Applicable Certificate of Authorization Number                      Not Applicable              Expiration Date              Not Applicable Signed                                                        Aaron Best, Engineer  Date                      6/17/2008 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of ,A.t',xTw' Ll                                and employed by                    HSB CT of                                      Hartford, Connecticut                              have inspected the components described in this Owner's Report during the period                          7-__ ,_-_,    _  to    _      7_-./
___-___Of                , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
_________________________                                    Commissions          /"V      ,/,,"
                  - '--lnspector's Signature                                            National Board, State, Province, and Endorsements 7_-_ _-        _  _  _
Date
 
Form NIS-2 Owner's Report for Repair/Replacement Activity
                                                                                                      'if-As required by the provisions of the ASME Code Section X1 Work Order Number                Sheet 1780859                      I of    2
: 1. Owner                                              2. Plant                                                    Unit Duke Power Company                                    Oconee Nuclear Station                                    ONS - 1 526 South Church Street                                7800 Rochester Hwy                                Date Charlotte, NC 28201-1006                              Seneca, SC 29672                                        4/7/2008
: 3. Work Performed by                                                              Type Code Symbol Stamp Not Applicable Duke Power Company                                                      Authorization Number 526 South Church Street                                                                    Not Applicable Charlotte, NC 28201-1006                                                Expiration Date Not Applicable        '
: 4. Identification of System, ASME Class Condenser Circulating Water System, ASME Class 3 5.
(a) Applicable Construction Code:            USAS B31.1          19    67  Edition,      No        Addenda,      No        Code Case (b) Applicable Edition Section XI Utilized For R/R Activity      19    98  Edition,      2000      Addenda.
(c) Applicable Section XI Code Case(s)          None
: 6. Identification of Components Name of              Name of          Manufacturer        National            Other            Year    Corrected,        ASME Component            Manufacturer      Serial Number      Board No.      Identification        Built    Removed,          Code or Installed    Stamped (Yes / No) mm                      4-                  I                  4                                    1        I                I ICCW PU 0004                Sulzer          550-50296-4          UNK                None            UNK      Corrected          NO
                        +                  4-                1                                    1        I                1
                        +                  4-                4              4-                    I        4                4
                        +                  4-                4              4-                    *
* 4
                        .1.                4.                4              4                    I        4                4
: 7. Description of Work The ID CCW pump packing gland was removed so that the packing gland studs could be replaced. The original bronze studs have been failing in service. New stainless steel studs have been recommended by the vendor. The studs on the ID pump have not failed, but are being replaced as a preventative measure.
: 8. Test Conducted D  Hydrostatic    [: Pneumatic      Z Nominal Operating Pressure      l  Exempt      - Other Pressure                PSI              Test Temperature                    OF
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number                  Sheet 1780859                      2 of 2
: 9. Remarks (Applicable Manufacturer's Data Reports to be attached) o Installed 2 new packing gland studs - ASTM A193          B8 - Heat Number 151723 V.
* Installed 2 new packing gland nuts - ASME SA194 Grade 8M - Heat Number -S/r" "r-- E5 --    -    5a of 0
0 0
0 0
0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.
Type Code Symbol Stamp                                                      Not Applicable Certificate of Au orizatiorNumber                    Not Applicable                Expiration Date              Not Applicable Sinned                                  IZz i ji-1                            Engineer      Date                    4/07/2008 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of I(fYv'.            6    -,vz    '        and employed by                    HSB CT of                                Hartford, Connecticut                                  have inspected the components described in this Owner's Report during the period                  fl- 7 -,6              to        7 0 8                    , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By sidning this certificate neither the Inspector nor his employer makes. any warranty, expressed or implied' concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
            *      '~~~--_                    _Commissions                    A/'/,J/,A'
                  `Tripector's Signature                                              National Board, State, Province, and Endorsements Date        7-___-            __
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by thie provisions of the ASME Code Section XI
                                                                                                          -I        -
Work Order Number              Sheet 01809497                    I of 2
: 1. Owner                                                2. Plant                                                    Unit Duke Power Company                                      Oconee Nuclear Station                                ONS - I 526 South Church Street                                7800 Rochester Hwy                              Date Charlotte, NC 28201-1006                                Seneca, SC 29672                                      6/1612008
: 3. Work Performed by                                                                Type Code Symbol Stamp Not Applicable IDuke Power Company                                                    Authorization Number 526 South Church Street                                                                  Not Applicale Expiration Date  N      icable Charlotte, NC 28201-1006 Not Applicable System, ASME Class
: 4. Identification of High Pressure ]njection, ASME Class 3 5.
(a) Applicable Construction Code:            USAS 131.7            19  69  Edition,        No    Addenda,      No      Code Case (b) Applicable Edition Section XI Utilized For R/R Activity          19  98  Edition,      2000    Addenda.
(c) Applicable Section XI Code Case(s)          None
: 6. Identification of Components Name of              Name of        Manufacturer        National            Other        Year      Corrected,      ASME Component              Manufacturer      Serial Number      Board No.        Identification    Built    Removed,          Code or Installed    Stamped (Yes / No)
(I) 550-47910      -          DPCo                None              'None              None        2008      Corrected        NO (2)1'-0-405      9A (2) 51A-0-479A                DPCo                None            None                None          2008      Corrected          NO EKK-H 1701 Piping                        DPCo                None            None                None          2008      Installed        NO
: 7. Description of Work OD 102249 installed pipilng and supports to provide additional temper-atre monitoring capability and to ensure a reservoir of water to the backside of the RCP seals.
: 8. Test Conducted
              -] hlydrsttidc    [-I Pneumatic    [Nominal Operating Pressure          ] Exetpt    El Other Pressure                PSI              Test Temperature
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As requicLd by the provisions of the ASME Code Section X1 Work Order Number                                    Sheet, 01809497                                  2 of' 2
: 9. Remarks (Applicable Manufacturer's Data Reports to be attached) 0  Support 55-0-479E-RTiB-H0501, attached QA-4 3" X 3" X 3/8" angle.
0 Support 51 A-0-479A-EKK-H 1701, Removed 3" channel and 1/2'* plate. Replaced with 2" X 2" X 1/4" angle and 1/2' plate.
Replaced bolling wilh 1/2" threaded rod and nuts.
C                        OFCOMPLIANCE
              .......
                  ......... ._---            -------------        -...                          ....                                              _  -----..
_.        . .._  .... _---              -
_.._......._._---
_-
0r'                              De___ee___l SectionANE Code                                  CERIFIAT Type Code, Sectiol StmXItAplcal TydeC y b l S a p ................ ......................... .................................----------...................
                                                                                                          ......_...........................
                                                                                                                ... p l . b.o      e ' _.....i..
                                                                                                                                    ...                      ...... .............
                                                                                                                                                                              . ---------
                                                                                                                                                                                        --------_
Certificate of Authorization Num~ber .                            ... Not__A__.icz?!icble..                .      Expiration Date ............... N                ..Ap )IicablZe .........
Signed      Ae&#xfd;/          *:
* Rick Bu,.-.css/Sr.1Tcchnical Specialist                                    Date                :                    1620 r                                                                                                                                                                                                    I CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of AlJoer,/                                    ,        ,        ,          and employed by                                      HSB CT of                                Hartford, Connecticut                                                                      have inspected the components described in this Owner's Report during the period                                              ,-- - o,                  to          6          08                              ,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
Com m    m............s.
issions.......            .        ................ ...........
Dtecor'ssigriatre                                                                                  Natonal Roard. State, Province.andt EnlorsnenieOs Date        t.'-/7 -o 6
 
  . Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section X1
                                                    -
                                                  ,/-/A  / / V-71                        Work Order Number              Sheet I    01738440                      I of 2
: 1. Owner                                              2. Plant                                                      Unit Duke Power Company                                      Oconee Nuclear Station                                    ONS - 1 526 South Church Street                                7800 Rochester Hwy                                Date Charlotte, NC 28201-1006                                Seneca, SC 29672                                        4/22/2008
: 3. Work Performed by                                                                Type Code Symbol Stamp Not Applicable Duke Power Company                                                        Authorization Number 526 South Church Street                                                                      Not Applicable Charlotte, NC 28201-1006                                                  Expiration Date Not Applicable
: 4. Identification of System, ASME Class Main Steam System, ASME Class 3 5.
(a) Applicable Construction Code:          USAS B31.1            19    67    Edition,      No      Addenda,      No        Code Case (b) Applicable Edition Section XI Utilized For R/R Activity        19    98    Edition,      2000    Addenda.
(c) Applicable Section Xl Code Case(s)          None                                                                        ")
: 6. Identification of Components Name of              Name of        Manufacturer          National              Other          Year    Corrected,        ASME Component          Manufacturer      Serial Number        Board No.          Identification      Built    Removed,          Code or Installed    Stamped (Yes / No)
                          *
* 4                      +        4 Piping                      DPCO                None            None                  None          2008      Installed        NO (I) Support                DPCO                None            None                  None          2008    Corrected          NO 1-OIA-441I-H4504
: 7. Descriotion of Work OE101603 - rebuilt piping to be more resistant to vibration using 2:1 taper welds at socket welded joints.
-  I
: 8. Test Conducted
                ] Hydrostatic    1  Pneumatic    Z Nominal Operating Pressure        E    Exempt        Other Pressure                PSI              Test  Temperature                    OF
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section X1 I Work Order Number                  Sheet 01738440                        2 of  2
: 9. Remarks (Applicable Manufacturer's Data Reports to be attached) 0 Existing pipe clamp removed for piping change then reinstalled. No new material used: No modification to support.
0 CO 0
CERIFIAT    OFde COMPLIANCE.
Type Code Symbol Stamp                                                  Not Applicable
* Certificate of Authorization Number                  Not Applicable          Expiration Date              Not.Applicable Signed                  91/k-'                                              Date4  _    __        __      __        __    _
Ownerf~r Owner' s Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of i),t.er.-                              n mlydb                          HSB CT of                                  Hartford, Connecticut                          have inspected the components described in this Owner's Report during the period              6-7-o a7              to        V-V-08                        , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
            * ~~ 'Inspectoir's
                                ~
Signature CommissionsA/      /        6 National Board, State, Province, and Endorsements Date  _  "-    __      _  __    _
 
          , m NIS-2 Owner's Report for Repair/Replacement Activities As required by the provisions of the ASME Code Section Xl                                                        Work Order Numbe                Sheet 01776264 - 04                          Page 1 of 2
- F                                                                                                                                                  unit
[.Owner          Duke Power Company                                          2. Plant    Oconee Nuclear Station                                  Unit 526 South Church Street                                                  7800 Rochestor Hwy Date    5/6/2008 Charlotte, NC 28201-1006                                                Seneca, SC 28672
: 3. Work Performed By                                                                                                    Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street                                                                                                            Not Applicable Charlotte, NC 28201-1006                                                                                  Expiration Date          Not Applicable
: 4. Identification of Systems, ASME Class Main Feedwater    ,  ASME Class 3 5.
(a) Applicable Construction Cod  USAS B31.1                1967:  Edition,  No    Addenda No    Code Case (b) Applicable Edition Section Xi Utilized For R/R Activity 1998:  Edition,  2000    Addenda (c) Applicable Section XI Codes Cases(s)          None
: 6. Identification of Coimponents Name of Component                      Manufacturer:          Manufacturer          National      Other            Year      Corrected,        ASME Code Serial Number        Board No    identification      Built  Removed or          Stamped Installed        (Yes/No)
(1) Replace Snubber 1-03-0-551-R12                  Grinnell              16612                  UNK          N/A                UNK      Removed          No (2) Replace Snubber 1-03-0-551-R12                  Anvil                36709                  UNK          UTC                UNK      Installed        No 1847026
: 7. Description of Work Replaced snubber due to seal life.
: 8. Test Conducted
[] Hydrostatic                D Pnuematic                E] Nominal Operating Pressure            D] Excempt          RJ    Other      Visual Pressure                          PSI                                                Test Temperature                        Deg. F
 
    .rm NIS-2 Owner's Report for Repair/Replacement Activities As required by the provisions of the ASME Code Section XI                                                            Work Order Numbe                Sheet 01776264 -04                  Page 2 of 2
: 7. Remarks (Applicable Manufactuerres Data Reports to be attached)
(1) Replaced sniubber due to seal life.
CERTIFICATION OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl Type Code Symbol Stamp                                                                  Not Applicable Certificate of Aut),erization Number                            Not Applicable                        Expiration Date                Not Applicable Signed                                                                                                Date          -___/_/___
Owner or Owners Designee, Title CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and State or province of                    -,ej.zsve
                                                                    '    1_,A,4,        and employed by                          HSB CT of                              Hartford, Connecticut                                    have inspected rthe components described in the Owner's Report during the period                                      o')'-,/_3" to          ' S'-GJ-.                    , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the inspector nor his employer make any warrenty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind rising from or connected with this inspection.
Commision(s)          aJL 1%'WA)/Ade n      s Signature                                                        National Board, State, Province, and Endorsements Date        S7e
 
Form NIS-2 Owner's Report for Repair/Replacement Activities As required by the provisions of the ASME Code Section Xl                                                          Work Order Numbe Sheet 01811089 - 01                          Page 1 of 2
/
: 1. Owner        Duke Power Company                                            2. Plant    Oconee Nuclear Station                                  unit 526 South Church Street                                                    7800 Rochestor Hwy Seneca, SC 28672                                        Date    5/22/2008 Charlotte, NC 28201-1006
: 3. Work Performed By                                                                                                      Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street                                                                                                              Not Applicable Charlotte, NC 28201-1006                                                                                    Expiration Date          Not Applicable
: 4. Identification of Systems, ASME Class Emergency Feedwater          ,  ASME Class 3 5.
(a) Applicable Construction Cod    USAS B31.1              1967:  Edition,  No      Addenda No    Code Case (b) Applicable Edition Section Xl Utilized For R/R Activity 1998:  Edition,  2000    Addenda (c) Applicable Section Xl Codes Cases(s)          None
: 6. Identification of Coimponents Name of Component                        Manufacturer:          Manufacturer            National      Other            Year      Corrected,        ASME Code Serial Number          Board No    identification      Built    Removed or            Stamped Installed          (Yes/No)
(1) S/R 1-03A-1-0-400A-SR53 -                        N/A                  N/A                      UNK          N/A                UNK      Removed            No W5X1 6, A-36 (2) 4 -1/2" Phillips SD anchor                      N/A                  N/A                      UNK          N/A                UNK      Removed            No 4 - 5/8" Hilti KBII anchor 7" LG                    N/A                    N/A                    UNK          UTC                UNK      Installed          No 1900189 S/R 1-03A-1-0-400A-SR53 - 1/2"                      N/A                  N/A                    UNK          N/A                UNK      Removed            No PLATE, A-36 S/R 1-03A-1-0-400A-SR53 - 1/2"                      N/A                  N/A                    UNK          UTC                UNK      Installed          No PLATE, A-36                                                                                                    1905900 S/R 1-03A-1-0-400A-SR53 -                            N/A                  N/A                    UNK          UTC                UNK      Installed          No W5X16, A-36                                                                                                    1043054 7- Description of Work Replaced damaged anchors due to EFW waterhammer. 1/2" plate & W5x16 replaced for convinence of installation. 5/8" Hilti KBII anchors were used as acceDtable substitution Der OSS-0020-00.00.0004 Sect. C 7.0
: 8. Test Conducted D    Hydrostatic              LI  Pnuematic              [  Nominal Operating Pressure            LI  Excempt          [      Other      Visual Pressure                          PSI                                                  Test Temperature                          Deg. F
 
Form NIS-2 Owner's Report for Repair/Replacement Activities As required by the provisions of the ASME Code Section Xl                                                        Work Order Numbe                Sheet 01811089    -  01            Page2of2
: 7. Remarks (Applicable Manufactuerr's Data Reports to be attached)
(1) Replaced damaged anchors due to EFW waterhammer. 1/2" plate & W5x1 6 replaced for convinence of installation.
(2) 5/8" Hilti KBII anchors were used as acceptable substitution per OSS-0020-00.00.0004 Sect. C 7.0 CERTIFICATION OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl Type Code Symbol Stamp                                                            Not Applicable Certificate of Autherization Number                          Not Applicable                      Expiration Date                Not Applicable Signed                                              *>                                          Date              ./*Z      /    0 Owner or Owners Designee, Title CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and State or province of 41oPr.4V L'_,*,,*Aj,.                      and employed by                          HSB CT of                              Hartford, Connecticut                                have inspected the components described in the Owner's Report during the period                      S'-'-      o
* to t - V--o                              , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the inspector nor his employer make any warrenty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind rising from or connected with this inspection.
Commision(s)        ,,,,.46,dc._
Z lns  o'&#xfd;
                        .s Signature                                                  National Board, State, Province, and Endorsements Date    ,"  -
 
Form NIS-2 Owner's Report for Repair/Replacement Activities As required by the provisions of the ASME Code Section Xl                                                                                          Sheet Work Order Numbe 01745444 - 01                        Page 1 of 2 1.Owner        Duke Power Company                                          2. Plant    Oconee Nuclear Station                                  unit 526 South Church Street                                                  7800 Rochestor Hwy Date    5/27/2008 Charlotte, NC 28201-1006                                                Seneca, SC 28672
: 3. Work Performed By                                                                                                    Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street                                                                                                            Not Applicable Charlotte, NC 28201-1006                                                                                  Expiration Date          Not Applicable
: 4. Identification of Systems, ASME Class Vents - Reactor Bldg. Components          ,  ASME Class 3 5.
(a) Applicable Construction Cod    USAS B31.1              1967:  Edition,  No      Addenda No    Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 1998:  Edition,  2000    Addenda (c) Applicable Section Xl Codes Cases(s)          None
: 6. Identification of Coimponents Name of Component                        Manufacturer:          Manufacturer          National      Other            Year      Corrected,      ASME Code Serial Number        Board No    identification      Built    Removed or          Stamped Installed        (Yes/No)
(1) S/R 57-0-481A-H26 - Ext. piece                  Grinnell              N/A                    UNK          N/A                UNK      Removed          No for Grinnell snubber size 2 1/2 x 5.
S/R 57-0-481A-H26 - Ext. piece for                  Anvil                  N/A                    UNK          UTC                UNK      Installed        No Grinnell snubber size 2 1/2 x 5.                                                                              1902456
: 7. Description of Work Replaced ext. piece on Grinnell size 2 1/2 x 5 snubber due to damaged threads at paddle end.
: 8. Test Conducted
[] Hydrostatic                E] Pnuematic                E] Nominal Operating Pressure            []  Excempt          [      Other      Visual Pressure                          PSI                                                Test Temperature                        Deg. F
 
Form NIS-2 Owner's Report for Repair/Replacement Activities As required by the provisions of the ASME Code Section Xl                                                        Work Order Numbe                  Sheet 01745444        -01            Page 2 of 2 1
: 7. Remarks (Applicable Manufactuerr's Data Reports to be attached)
(1) Replaced ext. piece on Grinnell size 2 1/2 x 5 snubber due to damaged threads at paddle end.
CERTIFICATION OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI Type Code Symbol Stamp                                                              Not Applicable Certificate of Autherization Number                            Not Applicable                      Expiration Date                    Not Applicable Signed      . t  j'.        4_2          -,-*  A",.                                            Date            --  __',__/___
Owner or Owners Designee, Title CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and State or province of AloAM-'                        -            and employed by                          HSB CT of                              Hartford, Connecticut                                have inspected the components described in the Owners Report during the period                    51'-Z.Z - 6              to        < - V"-ed                          , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code, Section Xl.
By signing this certificate neither the inspector nor his employer make any warrenty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind rising from or connected with this inspection.
SCommision(s)                VJC /'flwl.4            C.
Inspector's signature                                                  National Board, State, Province, and Endorsements Date
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI
                                                                                                        -Y Work Order Number              Sheet 01669084                    I of 2 1
: 1. Owner                                              2. Plant                                                    Unit Duke Power Company                                      Oconee Nuclear Station                                  ONS - 1 526 South Church Street                                7800 Rochester Hwy                              Date Charlotte, NC 28201-1006                                Seneca, SC 29672
: 3. Work Performed by                                                              Type Code Symbol Stamp Not Applicable Duke Power Company                                                      Authorization Number 526 South Church Street                                                                    Not Applicable Charlotte, NC 28201-1006                                                Expiration Date Not Applicable
: 4. Identification of System, ASME Class High Pressure Injection, ASME Class 3 5.
(a) Applicable Construction Code:          USAS B31.7            19    68  Edition,      No    Addenda,      No      Code Case (b) Applicable Edition Section XI Utilized For R/R Activity        19    98  Edition,      2000    Addenda.
(c) Applicable Section XI Code Case(s)        None
: 6. Identification of Components Name of              Name of        Manufacturer          National            Other        Year    Corrected,          ASME Component          Manufacturer      Serial Number        Board No.        Identification    Built    Removed,          Code or Installed      Stamped
                                                                                                                              -(-Yes./ No) -
Piping                      DPCo                None            None                None        2006      Installed;          NO
: 7. Description of Work Remove 2 1/2" pipe and fittings. Install 2 1/2" pipe,,elbow and 2 1/2" x I" reducer.
: 8. Test Conducted
[-] Hydrostatic , ["]Pneumatic        0  Nominal Operating Pressure    E-] Exempt    [! Other  MP/0/A1720/017 Pressure                PSI                Test Temperature                  oF a
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number                  Sheet 0                                                                                                    01669084                      2 of 2
: 9. Remarks (Applicable Manufacturer's Data Reports to be attached) 0 0
0 0
0 Q
o 0
CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.
Type Code Symbol Stamp                                                          Not Applicable Certificate of Authorization Number                      Not Applicable            Expiration Date              Not Applicable Signed                      H4.e*a          David Hubbard/Technical Specialist II  Date                        1    2006 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel.
Inspectors and the State or Province of JU,,.rV Z*.,e,*1/.,,                        and employed, by                      HSB CT of                                      Hartford, Connecticut                                have inspected the components described in this Owner's Report during the period                      e -Zo - .0 7        to        *. 0 9                    , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. -
___________________*_______                                  Commissions          /*/%/'    ,/d'4.
                      -  -nspector's  Signature                                          National Board, State, Province, and Endorsements Date    _    /_____________
 
-  trm NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI q
Work Order Number              Sheet Z eRA                      1792406                    I of 2 I                                1 4 1. Owner                                              2. Plant                                                    Unit Duke Power Company                                      Oconee Nuclear Station                                  ONS - 1 526 South Church Street                                7800 Rochester Hwy                              Date Charlotte, NC 28201-1006                                Seneca, SC 29672                                      5/9/2008
: 3. Work Performed by                                                              Type Code Symbol Stamp Not Applicable Duke Power Company                                                      Authorization Number 526 So':th Church Street                                                                  Not Applicable Charlotte, NC 28201-1006                                                Expiration Date Not Applicable
: 4. Identification of System, ASME Class Low Pressure Service Water, ASMEClass,3 5.
(a) Applicable Construction Code:          USAS B331.7          19    68  Edition,      No    Addenda,      NO      Code Case (b) Applicable Edition Section Xl Utilized For R/R Activity      19    98  Edition,      2000    Addenda.
(c) Applicable Section Xl Code Case(s)        None
: 6. Identification of Components Name of              Name of          Manufacturer        National            Other        Year      Corrected,      ASME Component          Manufacturer        Serial Number      Board No.        Identification    Built    Removed,          Code or Installed    Stamped (Yes / No)
(1) Support 1-14B-0-439B-                DPCo                None            None                None          1970    Corrected          NO RMC-0503
  -Piping                    DPCo                None            None                None        2008      Installed        NO
: 7. Description of Work Remove 8" pipe, fittings and flanges. Install 8" pipe, elbows and flanges. Install 1/2" half coupling, pipe and pipe cap.
Install 3/4" threaded rod-wash-ers and nuts. Refurbished I support.
: 8. Test Conducted E    Hydrostatic    1---Pneumatic        Nominal Operating Pressure    [-] Exempt        Other  MP/0/A/1720/017 Pressure                PSI              Test Temperature                  OF
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI I
Work Order Number                  Sheet 1792406                      2 of 2 1
: 9. Remarks (Applicable Manufacturer's Data Reports to be attached) o Support 1-14B-0-439B-RMC-0503, Replaced 4" sch. 40 pipe. Replaced 1/2" x 10" x 10" plate. Replaced l" x I I" x II" plate with 1/4" x I" x I I" plate.
0 0
0 0
Q 0
0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.
Type Code Symbol Stamp                                                  Not Applicable Certificate of Authorization Number                  Not Applicable            Expiration Date              Not Applicable Signed      ..      /              , David Hubbard/Technical Specialist II    Date                      5/9/2008 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of ,Voer1 .,n.,              ,o,ev        and employed by                    HSB CT of                                Hartford, Connecticut                              have inspected the components described in this Owner's Report during the period                S. &- -o0            to        d-- Y*0,                      , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section X1.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the.
Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
Commissions      ,,K'v,."              c, i
Insp&tor's Signature                                          National Board, State, Province, and Endorsements Date
 
F                                                                .7j Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI U
Work Order Number                Sheet 1752296                      I of 2
: 1. Owner                                                2. Plant                                                        Unit Duke Power Company                                        Oconee Nuclear Station                                    ONS - 1 526 South Church Street                                  7800 Rochester Hwy                                  Date Charlotte, NC 28201-1006                                  Seneca, SC 29672                                        4/30/2008.
: 3. Work Performed by                                                                  Type Code Symbol Stamp Not Applicable Duke Power Company                                                          Authorization Number 526 South Church Street                                                                        Not Applicable Charlotte, NC 28201-1006                                                    Expiration Date Not Applicable
: 4. Identification of System, ASME Class High Pressure Injection, ASME Class 3 5.
(a) Applicable Construction Code:            USAS B31.7              19    69  Edition,        No      Addenda,        No      Code Case (b) Applicable Edition Section XI Utilized For R/R Activity          19    98  Edition,      2000    Addenda.
(c) Applicable Section XI Code Case(s)            None
: 6. Identification of Components Name of            Name of          Manufacturer            National            Other            Year    Corrected,        ASME Component          Manufacturer      Serial Number          Board No.          Identification      Built    Removed,          Code or Installed    Stamped (Yeg / No)
(l)Piping                  DPCo.                None              None                None            2008      Installed          NO
______                1.                  1______            1_____            1 ______              11 i
___      _____            ___
: 7. Description of Work OE101772 replaced 1 obsolete 3/4" valve, IHP-143, with 1" valve item # 09J-2005 and replaced 3/4" pipe with 1.
Note: Valve and pipe is 1", ISI C. Only the 1-1/2" x I" reducing insert used is addressed by this NIS-2.
-K
: 8. Test Conducted D  Hydrostatic    0  Pneumatic      [* Nominal Operating Pressure      E]Exempt        E  Other Pressure                  PSI                Test Temperature                    OF
 
I Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number                  Sheet
*01                                                                                            -Sz+5  Z                          2 of 2
: 9. Remarks (Applicable Manufacturer's Data Reports to be attached) o  One 1-1/2" x I" reducing insert (UTC# 928535, Cat ID# 113708) was added to replace existing 1-1/2" x 3/4" reducing insert.
0 0
0 0
o 0
0 0
CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.
Type Code Symbol Stamp                                                      Not Applicable Certificate of Authorization Number                      Not Applicable          Expiration Date              Not Applicable Signed        '4.        /            j                                        Date  _      '/_                        _    _
e-nr'ror Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of ./o.e,,/                  ,            and employed by                    HSB CT of                                    Hartford, Connecticut                            have inspected the components described in this Owner's Report during the period                      7-/4-o7            to          f -oB
                                                                                                .-                          ,and state that to the best of. my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section X1.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
_      _        __*_&#xfd;__                                      Commissions    /'-/      )/-*d/.
Inspector's Signature                                          National Board, State, Province, and Endorsements Date      Z_ "-_Y____  8_
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI I
Work Order Number              Sheet 1731062-05                  1 of 2
*1. Owner                                            2. Plant                                                  Unit Duke Power Company                                    Oconee Nuclear Station                                ONS - 0 526 South Church Street                              7800 Rochester Hwy                              Date Charlotte, NC 28201-1006                              Seneca, SC 29672                                    1/16/2008
: 3. Work Performed by                                                            Type Code Symbol Stamp Not Applicable Duke Power Company                                                    Authorization Number 526 South Church Street                                                                Not Applicable Charlotte, NC 28201-1006                                              Expiration Date Not Applicable
: 4. Identification of System, ASME Class UO Borated Water Storage Tank (BWST) Recirc. Pump, Inlet=4" Outlet- 3", ASME Class 3 5.
(a) Applicable Construction Code:        ASME Section Ill      19  74    Edition,      1975  Addenda,      No      Code Case (b) Applicable Edition Section Xl Utilized For RJR Activity      19    98  Edition,      2000    Addenda.
(c) Applicable Section Xl Code Case(s)        None
: 6. Identification of Components Name of              Name of        Manufacturer        National            'Other        Year    Corrected,      ASME Component          Manufacturer      Serial Number      Board No.      Identification    Built    Removed,        Code or Installed    Stamped (Yes I No)
Cover, Casing          Ingersoll-Rand          UNK              UNK                lJNK        UNK      Removed          NO CAT ID#285944 Cover, Casing          Ingersoll-Rand          UNK              UNK        PTC#957975                      Installed        NO 1C
: 7. Description ot Work The repair/replacement of the UO BWST Recirculation Pump mechanical seal was required due to abnormal leakage originating from the mechanical seal area. All other parts were inspected and replaced as needed.
: 8. Test Conducted.
lii] Hydrostatic    E] Pneumatic    D Nominal Operating Pressure    D Exempt        Z Other  VT-2 Visual Pressure                PSI              Test Temperature                  OF
 
i Form NIS-2 Owner's Report. for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.
Type Code Symbol Stamp                                                      -Not Applicable Certificate of utho ization Number                        Not Applicable            Expiration Date              Not Applicable Signe                              4 h,ristopher W. Compton, Associate Engineer    Date (        V 1)                f  -"..
O 0"    ror Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of .L..UherW'cs_,,*,Z,,u.,                    and employed by                    HSB CT of                                    Hartford, Connecticut                              have inspected the components described in this Owner's Report during the period                      7.-,. - 7            to          &#xfd;-- o 8                      , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's. Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
_______________________                                    Commissions ..                JV,,Ka'A._
Inspector's Signature                                          National Board, State, Province, and Endorsements Date              S._-d__-08
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI t
Work Order Number              Sheet 1682085                    I  of 2
: 1. Owner                                              2. Plant                                                    Unit Duke Power Company                                    Oconee Nuclear Station                                ONS- I 526 South Church Street                                7800 Rochester Hwy                              Date Charlotte, NC 28201-1006                              Seneca, SC 29672                                      2/20/08
: 3. Work Performed by                                                              Type Code Symbol Stamp Not Applicable Duke Power Company                                                      Authorization Number 526 South Church Street                                                                  Not Applicable Charlotte, NC 28201-1006                                                Expiration Date Not Applicable
: 4. Identification of System, ASME Class Emergency Feedwater, ASME Class 3 5.
(a) Applicable Construction Code:          USAS B31.7.          19    69  Edition,.      No    Addenda,      No      Code Case (b) Applicable Edition Section Xl Utilized For R/R Activity      19    98  Edition,      2000    Addenda.
(c) Applicable Section Xl Code Case(s)        None
: 6. Identification of Components Name of              Name of        Manufacturer        National            Other        Year      Corrected,      ASME Component            Manufacturer      Serial Number      Board No.        Identification    Built. Removed"        Code or Installed    Stamped (Yes / No)
S/R 1-03A-1            DPCo.              N/A              N/A                  N/A        2008      Corrected.      NO, 400B-H62
: 7. Description of Work.
Install missing fillet welds per S/R drawing.
Missing 1/4" fillet weld between C6 channel and WF beam.
A~Missinig 1/8" fillef'veld~between 1/2" plate (Item 9) and WF beam.
: 8. Test Conducted FI Hydrostatic      E] Pneumatic    1-" Nominal Operating Pressure      ] Exempt    El Other Pressure                PSI              Test Temperature                  OF
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI                            ,    .
I Work Order Number                  Sheet 1682085                      2 of 2
: 9. Remarks (Applicable Manufacturer's Data Reports to be attached) 0 0
0 0
0 0
0 0
CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.
Type Code Symbol Stamp                                                      Not Applicable Certificate of Authorization Number                    Not Applicable              Expiration Date              Not Applicable Signed                7        #(1                              Civil Engineer  Date                      2/27/2008
                      ,0 Owner or Owne-s-'signee, Title CERTIFICATE OF INSERVICE INSPECTION I,.the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of ,/o,,cr./                    a,,.,,Q    and employed by                      HSB CT of                                    Hartford, Connecticut                            have inspected the components described in this Owner's Report during the period                      //-JZ-o7          to          *--,'- o*                  , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with, the requirements of the ASME Code, Section Xl.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
Commissions      4JC-1Y'WAJ1Ad<-
S-            ector's Signature                                        National Board, State, Province, and Endorsements Date              S'--."- o6
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI U
Work Order Number                  Sheet 01767701-01                      I of 2
: 1. Owner                                                2. Plant                                                      Unit Duke Power Company                                      Oconee Nuclear Station                                    ONS - 1 526 South Church Street                                  7800 Rochester Hwy                                  Date Charlotte, NC 28201-1006                                Seneca, SC 29672                                        4/30/2008
: 3. Work Performed by                                                                Type Code Symbol Stamp Not Applicable Duke Power Company                                                        Authorization Number 526 South Church Street                                                                      Not Applicable Charlotte, NC 28201-1006                                                  Expiration Date Not Applicable
: 4. Identification of System, ASME Class Feedwater, ASME Class 3 5.
(a) Applicable Construction Code:          ASME Section 111        19  83    Edition,    W/1984      Addenda,      N/A      Code Case (b) Applicable Edition Section XI Utilized For R/R Activity        19    98  Edition,      2000      Addenda.
(c) Applicable Section XI Code Case(s)          None
: 6. Identification of Components Name of              Name of          Manufacturer          National            Other            Year    Corrected,        ASME Component            Manufacturer        Serial Number        Board No.        Identification        Built    Removed,          Code or Installed    Stamped (Yes / No)
Anderson IFDW-91                  Greenwood            97-63846            2582                N/A            1998      Removed          YES IFDW-91                    Anderson Greenwood            97-63844            2580                N/A            1998      Installed        YES
                      +                  .4.                .4.              J                    .L        L                L
                      +                  .4.                4                1                    .4.      1                1
: 7. Description of Work Replaced valve with a like for like (DMV-935) from stock.
TTest Conducted L  Hydrostatic    E Pneumatic      LI  Nominal Operating Pressure    [] Exempt      Z Other      F/V BY VIS/LKAGE CHECK Pressure                PSI                Test Temperature                    OF
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number                  Sheet S01767701-01                                                                                              2 of 2
: 9. Remarks (Applicable Manufacturer's Data Reports to be attached) o  IFDW-91, DMV-935, Catalog ID: 375501, UTC #: 987609, serial number: 97-63844 0
0 0
0 S
CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.
Type Code Symbol Stamp                                                      Not Applicable Certificate of Authorization Number                Not Applicable                Expiration Date              Not Applicable Signed        "6                    7*
Owner or O' ner's Designee, Title
                                                                  , Sr. Engineer    Date                        4-30-08 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of                                            and employed by                    HSB CT of                                Hartford, Connecticut                                  have inspected the components described in this Owner's Report during the period        _      5,/_/_f A    "          to            I/..,'/t.*                ,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
by signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property.damage or a loss of any kind arising from or connected with this inspection.
_ ___        ______C                                      Commissions        t/c    //l          /      7"-
Q Inspector's Signature                                              National Board, State, Province, and Endorsements Date    _I
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section X1 Work Order Number              Sheet 01739941
: 1. Owner                                            2. Plant                                                  Unit Duke Power Company                                  Oconee Nuclear Station                                ONS - 1 526 South Church Street                              7800 Rochester Hwy                              Date Charlotte, NC 28201-1006                            Seneca, SC 29672                                    5/24/2008
: 3. Work Performed by                                                            Type Code Symbol Stamp Not Applicable Duke Power Company                                                  Authorization Number 526 South Church Street                                                                Not Applicable Charlotte, NC 28201-1006                                            Expiration Date Not Applicable
: 4. Identification of System, ASME Class Component Cooling & Vents, RB Components, ASME Class 3 5.
(a) Applicable Construction Code:          USAS B31.1            19  67  Edition,      No    Addenda,      No      Code Case (b) Applicable Edition Section X1 Utilized For R/R Activity      19  98  Edition,      2000    Addenda.
(c) Applicable Section XACode Case(s)          None
: 6. Identification of Components Name of              Name of        Manufacturer        National            Other          Year    Corrected,      ASME Component          Manufacturer      Serial Number      Board No.      Identification      Built,  Removed,          Code or Installed    Stamped (Yes I No) 479E-H6462"/D~o 1                              Nn None            None              None          Unk      Installed        NO
() S/R 1 /
479E-H6462                  DPCo.
DPCo.              None            None              None          Unk      Installed        NO (2) S/R 1-55-~              DP~o.              None            None              None          Unk      Installed        NO (4) S/R 57  480A-H)9S5/                DPCo.              None            None              None          Unk      Installed        NO
: 7. Description of Work These supports interfered with the replacement of Reactor Coolant Pump Motor (RCPM) 1Al, These supports were removed and then reinstalled after RCPM IA1 was replaced.
: 8. Test Conducted D Hydrostatic        [D] Pneumatic  D-Nominal Operating Pressure          Exempt        Other Pressure                PSI              Test Temperature                  OF
 
Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number                  ISheetS6fCr-1739941
: 9. Remarks (Applicable Manufacturer's Data Reports to be attached) 0 S/R 1-55-479E-H6462; replaced beam attachment UTC 1895218, replaced tube steel UTC 1894541.
    @ S/R 1-55-479E-H6463, replaced tube steel UTC 1891638.
0 S/R 1-55-479E-H6656; replaced angle UTC 1894542 O S/R 57-0-480A-H19; replaced 1/2" bolts UTC 1910441, replaced 1/2" nuts UTC 1905927, replaced 1/2" washers UTC1898442, added 7/8" bolts UTC 0964196, added 7/8" nuts UTC 1823794, added 7/8" washers UTC 1848378, added CS plate UTC 1847368 and UTC 1895778, added angle UTC 1071333.
G CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.
Type Code Symbol Stamp                                                NotApplicable                            ____
Certificate of Authorization Number                Not Applicable          Expiration Date              Not&#xfd; Applicable Signed                                                                      Date  _______________
owner or Owner's Designee, TitleJ-F CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of .//ae r'            -1 .zoA        and employed by                    HSSB CT of                                Hartford, Connecticut                          have inspected the components described in this Owner's Report during the period                  . -//- o6'      to                      ,'E-D-z              , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
Commissions A,&./"/1"1V1A)            dc_
0    Date e l,-- _s.ccTo-'s Signatre
                                .9 0-2 National Board, State, Province, and Endorsements
 
6.0    PressureTestin, This summary is a pressure test completion status for the second period of the fourth ten-year interval. Table 6-1 shows the number of pressure tests completed from refueling outage EOC-23 through refueling outage EOC-24. There was no through-wall leakage observed during these pressure tests.
Table 6-1 Outage Specific Summary Total Examinations Examination                  Test Requirement                Credited For This Outage Category B-P              System Leakage Test (IWB-5220)                        1 C-H              System Leakage Test (IWC-5220)                      35 Table 6-2 shows a completion status for the number of pressure tests conducted during the second period of the fourth ten-year interval.
Table 6-2 Period Specific Summary Total          Total                (%)
Examination      Test Requirement      Examinations    Examinations        Examinations Category                              Required For    CreditedFor        Complete For, This Period    This Period        This Period B-P        System Leakage Test            2                1                50%
(IWB-5220)
C-H        System Leakage Test            53              35              53.93%
(IWC-5220)
The Class 1 (Category B-P) leakage test is required each refueling outage. Table 6-3 shows the completion data of the Class 1 (Category B-P) leakage test conducted during refueling cycle EOC24.
Table 6-3 DetailedClass 1 Listing EOC24 Zone                              Completion        EOC24 VT-2          Code Case(s)
Number      Boundary Dwg            Status        Examination Date            Used OZ1L-1A    O-ISIL4-100A-1.1        Complete          5/29/2008                None O-ISIL4-10OA-1.2        Complete          5/29/2008                None O-ISIL4-100A-1.3        Complete          5/29/2008                None O-ISIL4-101A-1.1        Complete          5/29/2008                None O-ISIL4-101A-1.4        Complete          5/29/2008                None O-ISIL4-102A-1.1        Complete          5/29/2008                None O-ISIL4-1 10A-1.1      Complete          5/29/2008                None O-ISIL4-i 1OA-1.4      Complete          5/29/2008                None O-ISIL4-102A-1.3        Complete          5/29/2008                None EOC 24 Refueling Outage Report                                                Page 1 of 4 Oconee Unit 1                                                                Revision 0 Section 6                                                                    July 8, 2008
 
The Class 2 (Category C-H) leakage tests are required once each period. Table 6-4 shows the completion data of the Class 2 (Category C-H) leakage tests completed through refueling cycle EOC24.
Table 6i-4 Detailed Class 2 Listina EOC24      EO0C24 VT-2          Code Zone                            Completion    Examination        Case(s)
Number          Boundary Dwg          Status          Date              Used 1    IZ1L-10      O-ISIL4-101A-1.3    Complete      4/12/2008            None 2      IZ1L-11      O-ISIL4-101A-1.3    Complete      4/12/2008            None 3    IZ1 L-12      0-ISIL4-101A-1.3  Not Yet Tested      N/A              N/A 0-ISIL4-101A-1.4  Not Yet Tested      N/A              N/A 4      IZ1L-13      O-ISIL4-101A-1.3    Complete        4/9/2008            None 5    IZ1L-14A      O-ISIL4-101A-1.3    Complete        5/6/2008            None 6    IZ1L-14B      O-ISIL4-101A-1.3    Complete        5/5/2008            None 7    IZ1L-20      O-ISIL4-101A-1.3    Complete        4/8/2008            None 8    IZ1 L-21      0-ISIL4-104A-1.2    Complete      5/25/2008            None 9    IZ1 L-22      O-ISIL4-101A-1.3  Not Yet Tested      N/A              N/A O-ISIL4-102A-1.1  Not Yet Tested      N/A              N/A O-ISIL4-102A-1.2  Not Yet Tested      N/A              N/A O-ISIL4-106A-1.2  Not Yet Tested      N/A              N/A O-ISIL4-104A-1.2  Not Yet Tested      N/A              N/A 10    IZ1 L-24      O-ISIL4-102A-1.1  Not Yet Tested      N/A              N/A 0-ISIL4-103A-1.1  Not Yet Tested      N/A              N/A 11    IZ1 L-25      O-ISIL4-102A-1.1  Not Yet Tested      N/A              N/A O-ISIL4-103A-1.1  Not Yet Tested      N/A              N/A 12      IZ1L-4      O-ISIL4-101A-1.1    Complete        4/8/2008            None 13    IZ1L-40      0-ISIL4-109A-1.1  Not Yet Tested      N/A              N/A 14    IZ1 L-41      O-ISIL4-109A-1.1  Not Yet Tested      N/A              N/A 15    IZ1 L-48      O-ISIL4-122A-1.1  Not Yet Tested      N/A              N/A 0-ISIL4-122A-1.2  Not Yet Tested      N/A              N/A 0-ISIL4-122A-1.3  Not Yet Tested      N/A              N/A 0-ISIL4-122A-1.4  Not Yet Tested      N/A              N/A O-ISIL4-122B-1.1  Not Yet Tested      N/A              N/A 16      IZ1L-5      O-ISIL4-101A-1.1  Not Yet Tested      N/A              N/A O-ISIL4-101A-1.3  Not Yet Tested      N/A              N/A 17    IZ1 L-60      O-ISIL4-124B-1.2    Complete        6/5/2008            None O-ISIL4-124B-1.4    Complete        6/5/2008            None 18  OZ1L-14B        O-ISIL4-101A-1.4  Not Yet Tested      N/A              N/A 19    OZ1 L-15      O-ISIL4-101A-1.4    Complete      5/29/2008            None 20    OZ1 L-1 6      0-ISIL4-101A-1.4    Complete      5/28/2008            None 21    OZ1 L-17      O-ISIL4-101A-1.2    Complete      5/27/2008            None 22  OZ1L-17B        0-ISIL4-101A-1.2    Complete        5/6/2008            None 23    OZ11L-18      O-ISIL4-101A-1.2    Complete      5/26/2008            None EOC 24 Refueling Outage Report                                            Page 2 of 4 Oconee Unit 1                                                            Revision 0 Section 6                                                                July 8, 2008
 
EOC24      EOC24 VT-2            Code Zone                          Completion    Examination        Case(s)
Number      Boundary Dwg        Status        Date              Used 24    OZ1L-19A    O-ISIL4-101A-1.5  Not Yet Tested      N/A              N/A O-ISIL4-104A-1.1  Not Yet Tested      N/A              N/A 25    OZ1L-19B    O-ISIL4-101A-1.5  Not Yet Tested      N/A              N/A 26    OZ1L-1A      O-ISIL4-101A-1.1    Complete      5/29/2008            None O-ISIL4-101A-1.5    Complete      5/29/2008            None 27    OZ1L-2      O-ISIL4-101A-1.1  Not Yet Tested      N/A              N/A 28    OZ1 L-21    O-ISIL4-102A-1.1    Complete      5/25/2008            None O-ISIL4-102A-1.2    Complete      5/25/2008            None 29    OZ1 L-23    O-ISIL4-101A-1.2    Complete      5/25/2008            None O-ISIL4-102A-1.1    Complete      5/25/2008            None O-ISIL4-102A-1.2    Complete      5/25/2008            None 30    OZ1 L-26    O-ISIL4-102A-1.2      Partial    5/25/2008            None 31    OZ1 L-27A    O-ISIL4-102A-1.2  Not Yet Tested      N/A              N/A 32    OZ1 L-27B    O-ISIL4-102A-1.1    "Complete    5/25/2008            None O-ISIL4-102A-1.2    Complete      5/25/2008            None 33    OZ1 L-28    O-ISIL4-102A-1.2    Complete      5/29/2008            None 34    OZ1 L-29    O-ISIL4-102A-1.2    Complete      5/25/2008            None 35    OZ1L-29A    O-ISIL4-102A-1.2    Complete      5/25/2008            None O-ISIL4-102A-1.3    Complete      5/25/2008            None 36    OZ1L-3      O-ISIL4-101A-1.1    Complete      5/29/2008            None 37    OZ1 L-30    O-ISIL4-102A-1.2    Complete      5/25/2008            None 38    OZ1 L-30A    O-ISIL4-102A-1.2    Complete    5/25/2008            None O-ISIL4-102A-1.3    Complete    5/25/2008            None 39    OZ1 L-31 A  O-ISIL4-102A-1.3    Complete    5/29/2008            None 40    OZ1 L-31B    O-ISIL4-102A-1.3    Complete    5/29/2008            None 41    OZ1 L-31C    O-ISIL4-102A-1.3    Complete    5/29/2008            None 42    OZ1 L-34    O-ISIL4-104A-1.1    Complete    4/19/2008            None 43    OZ1 L-39    O-ISIL4-104A-1.1  Not Yet Tested      N/A              N/A 44    OZ1 L-42A    O-ISIL4-1 1OA-1.1 Not Yet Tested      N/A              N/A 45    OZ1L-42B    O-ISIL4-11OA-1.1  Not Yet Tested      N/A              N/A 46    OZ1 L-44    O-ISIL4-110A-1.1  Not Yet Tested      N/A              N/A O-ISIL4-121 B-1.3 Not Yet Tested      N/A              N/A O-ISIL4-121B-1.5  Not'Yet Tested      N/A              N/A O-ISIL4-121 D-1.1 Not Yet Tested      N/A              N/A O-ISIL4-121D-1.2  Not Yet Tested      N/A              N/A O-ISIL4-122A-1.1  Not Yet Tested      N/A              N/A 47    OZ1 L-6    O-ISIL4-109A-1.1    Complete    5/26/2008            None 48    OZ1L-6B    O-ISIL4-101A-1.2    Complete    2/29/2008            None 49    OZ1 L-64    O-ISIL4-124B-1.2    Complete    5/29/2008            None 50    OZ1 L-65    O-ISIL4-124B-1.4    Complete    5/29/2008            None 51    OZ1L-7      O-ISIL4-101A-1.2    Complete      5/6/2008            None O-ISIL4-101A-1.3    Complete      5/6/2008            None EOC 24 Refueling Outage Report                                      Page 3 of 4 Oconee Unit 1                                                        Revision 0, Section 6                                                            July 8, 2008
 
EOC24    EOC24 VT-2            Code Zone                          Completion Examination        Case(s)
Number        Boundary Dwg      Status      Date              Used 52    OZ1L-7B      O-ISIL4-101A-1.3  Complete    5/6/2008            None O-ISIL4-102A-1.2  Complete    5/6/2008            None 53    OZ1 L-9      O-ISIL4-101A-1.3  Complete  5/25/2008            None 0-ISIL4-102A-1.2  Complete  5/25/2008            None Section 6 Prepared By:                              Date:
Section 6 Reviewed By:                              Date:
26Z          ,4,"    (/                                  7                                                                    ___-_
EOC 24 Refueling Outage Report                                    Page 4 of 4 Oconee Unit 1                                                      Revision 0 Section 6                                                          July 8, 2008}}

Latest revision as of 15:18, 14 January 2025

Inservice Inspection Report for End of Cycle 24 Refueling Outage, Fourth Ten-Year Inservice Inspection Interval
ML082490152
Person / Time
Site: Oconee Duke Energy icon.png
Issue date: 08/28/2008
From: Baxter D
Duke Energy Carolinas, Duke Energy Corp
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
Download: ML082490152 (266)


Text