IR 05000269/2011402: Difference between revisions
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
StriderTol (talk | contribs) (StriderTol Bot change) |
||
| (One intermediate revision by the same user not shown) | |||
| Line 18: | Line 18: | ||
=Text= | =Text= | ||
{{#Wiki_filter: | {{#Wiki_filter:September 22, 2011 | ||
==SUBJECT:== | ==SUBJECT:== | ||
| Line 24: | Line 24: | ||
==Dear Mr. Gillespie:== | ==Dear Mr. Gillespie:== | ||
On August 25, 2011, the U. S. Nuclear Regulatory Commission (NRC) completed a security baseline inspection at your Oconee Nuclear Station Units 1, 2 and 3. The inspection covered one or more of the key attributes of the security cornerstone of the | On August 25, 2011, the U. S. Nuclear Regulatory Commission (NRC) completed a security baseline inspection at your Oconee Nuclear Station Units 1, 2 and 3. The inspection covered one or more of the key attributes of the security cornerstone of the NRCs Reactor Oversight Process. The enclosed report documents the inspection results which were discussed on August 25, 2011, with Mr. R. Guy, and other members of your staff. | ||
This inspection examined activities conducted under your license as they relate to security and compliance with the | This inspection examined activities conducted under your license as they relate to security and compliance with the Commissions rules and regulations, and with the conditions of your license. The inspector reviewed selected procedures and records, observed activities, and interviewed personnel. | ||
Based on the results of this inspection, no findings were identified. | Based on the results of this inspection, no findings were identified. | ||
In accordance with 10 CFR 2.390 of the NRC's "Rules of Practice," a copy of this letter will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of NRC's document system, ADAMS. ADAMS is accessible from the NRC Website at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room). However, because of the security-related concerns contained in the enclosure, and in accordance with 10 CFR 2.390, a copy of this | In accordance with 10 CFR 2.390 of the NRC's "Rules of Practice," a copy of this letter will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of NRC's document system, ADAMS. ADAMS is accessible from the NRC Website at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room). However, because of the security-related concerns contained in the enclosure, and in accordance with 10 CFR 2.390, a copy of this letters enclosure will not be available for public inspection. | ||
In accordance with 10 CFR 2.390(b)(1)(ii), the NRC is waiving the affidavit requirements for your response, if any. This practice will ensure that your response will not be made available electronically for public inspection in the NRC Public Document Room or from the | In accordance with 10 CFR 2.390(b)(1)(ii), the NRC is waiving the affidavit requirements for your response, if any. This practice will ensure that your response will not be made available electronically for public inspection in the NRC Public Document Room or from the NRCs document system, ADAMS. If Safeguards Information is necessary to provide an acceptable DPC | ||
2 response, please provide the level of protection described in 10 CFR 73.21. Otherwise, mark your entire response Security Related Information-Withhold Under 10 CFR 2.390" and follow the instructions for withholding in 10 CFR 2.390 (b)(1). | |||
Sincerely, | Sincerely, | ||
/RA/ | /RA/ | ||
Michael E. Ernstes, Chief Plant Support Branch 2 Division of Reactor Safety Docket Nos.: 50-269, 50-270, 50-287 License Nos.: DPR-38, DPR-47, DPR-55 | |||
Michael E. Ernstes, Chief Plant Support Branch 2 Division of Reactor Safety | |||
Docket Nos.: 50-269, 50-270, 50-287 License Nos.: DPR-38, DPR-47, DPR-55 | |||
Enclosure: | |||
Inspection Report 05000269/2011402, 05000270/2011402, and 05000287/2011402 w/Attachment: Supplemental Information (OUO) | |||
cc: (See page 3) | |||
ML112650776 | |||
X SUNSI REVIEW COMPLETE OFFICE RII: DRS RII: DRS RIII: DRP | |||
SIGNATURE RA RA RA VIA EMAIL | |||
NAME A.TRUE M.ERNSTES J.BARTLEY | |||
DATE 09/01/2011 09/22/2011 09/22/2011 | |||
E-MAIL COPY? | |||
YES NO YES NO YES NO YES NO YES NO YES NO YES NO DPC | |||
3 cc w/Encl: | |||
David A. Baxter Vice President, Nuclear Engineering Duke Energy Carolinas, LLC 526 S. Church St., EC08H Charlotte, NC 28202 | |||
David G. Black Fleet Security Manager Duke Energy Carolinas, LLC P. O. Box 1006 526 S. Church Street Charlotte, NC 28201-1006 | |||
Terry L. Patterson Safety Assurance Manager Duke Energy Carolinas, LLC Oconee Nuclear Station 7800 Rochester Highway Seneca, SC 29672 | |||
Terry W. King Site Security Manager Duke Energy Carolinas, LLC Oconee Nuclear Station 7800 Rochester Highway Seneca, SC 29672 | |||
Daniel C. Durham Security Support Oconee Nuclear Station Duke Energy Carolinas, LLC 7800 Rochester Highway Seneca, SC 29672 | |||
Timothy J. Wadsworth Security Specialist Duke Energy Carolinas, LLC P. O. Box 1006 526 S. Church St., EC05P Charlotte, NC 28201-1006 | |||
David | David A. Cummings Associate General Counsel Duke Energy Corporation P.O. Box 1006 526 S. Church St., EC07H Charlotte, NC 28201-1006 | ||
Kent Alter Regulatory Compliance Manager Oconee Nuclear Station Duke Energy Carolinas, LLC ON03RC 7800 Rochester Highway Seneca, SC 29672 | |||
}} | }} | ||
Latest revision as of 01:55, 13 January 2025
| ML112650776 | |
| Person / Time | |
|---|---|
| Site: | Oconee |
| Issue date: | 09/22/2011 |
| From: | Ernstes M NRC/RGN-II/DRS/PSB2 |
| To: | Gillespie P Duke Energy Carolinas |
| References | |
| IR-11-402 | |
| Download: ML112650776 (4) | |
Text
September 22, 2011
SUBJECT:
OCONEE NUCLEAR STATION - NRC SECURITY INSPECTION REPORT 05000269/2011402, 05000270/2011402, AND 05000287/2011402
Dear Mr. Gillespie:
On August 25, 2011, the U. S. Nuclear Regulatory Commission (NRC) completed a security baseline inspection at your Oconee Nuclear Station Units 1, 2 and 3. The inspection covered one or more of the key attributes of the security cornerstone of the NRCs Reactor Oversight Process. The enclosed report documents the inspection results which were discussed on August 25, 2011, with Mr. R. Guy, and other members of your staff.
This inspection examined activities conducted under your license as they relate to security and compliance with the Commissions rules and regulations, and with the conditions of your license. The inspector reviewed selected procedures and records, observed activities, and interviewed personnel.
Based on the results of this inspection, no findings were identified.
In accordance with 10 CFR 2.390 of the NRC's "Rules of Practice," a copy of this letter will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of NRC's document system, ADAMS. ADAMS is accessible from the NRC Website at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room). However, because of the security-related concerns contained in the enclosure, and in accordance with 10 CFR 2.390, a copy of this letters enclosure will not be available for public inspection.
In accordance with 10 CFR 2.390(b)(1)(ii), the NRC is waiving the affidavit requirements for your response, if any. This practice will ensure that your response will not be made available electronically for public inspection in the NRC Public Document Room or from the NRCs document system, ADAMS. If Safeguards Information is necessary to provide an acceptable DPC
2 response, please provide the level of protection described in 10 CFR 73.21. Otherwise, mark your entire response Security Related Information-Withhold Under 10 CFR 2.390" and follow the instructions for withholding in 10 CFR 2.390 (b)(1).
Sincerely,
/RA/
Michael E. Ernstes, Chief Plant Support Branch 2 Division of Reactor Safety
Docket Nos.: 50-269, 50-270, 50-287 License Nos.: DPR-38, DPR-47, DPR-55
Enclosure:
Inspection Report 05000269/2011402, 05000270/2011402, and 05000287/2011402 w/Attachment: Supplemental Information (OUO)
cc: (See page 3)
X SUNSI REVIEW COMPLETE OFFICE RII: DRS RII: DRS RIII: DRP
NAME A.TRUE M.ERNSTES J.BARTLEY
DATE 09/01/2011 09/22/2011 09/22/2011
E-MAIL COPY?
YES NO YES NO YES NO YES NO YES NO YES NO YES NO DPC
3 cc w/Encl:
David A. Baxter Vice President, Nuclear Engineering Duke Energy Carolinas, LLC 526 S. Church St., EC08H Charlotte, NC 28202
David G. Black Fleet Security Manager Duke Energy Carolinas, LLC P. O. Box 1006 526 S. Church Street Charlotte, NC 28201-1006
Terry L. Patterson Safety Assurance Manager Duke Energy Carolinas, LLC Oconee Nuclear Station 7800 Rochester Highway Seneca, SC 29672
Terry W. King Site Security Manager Duke Energy Carolinas, LLC Oconee Nuclear Station 7800 Rochester Highway Seneca, SC 29672
Daniel C. Durham Security Support Oconee Nuclear Station Duke Energy Carolinas, LLC 7800 Rochester Highway Seneca, SC 29672
Timothy J. Wadsworth Security Specialist Duke Energy Carolinas, LLC P. O. Box 1006 526 S. Church St., EC05P Charlotte, NC 28201-1006
David A. Cummings Associate General Counsel Duke Energy Corporation P.O. Box 1006 526 S. Church St., EC07H Charlotte, NC 28201-1006