ML13056A609: Difference between revisions
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
StriderTol (talk | contribs) (StriderTol Bot change) |
||
| (One intermediate revision by the same user not shown) | |||
| Line 15: | Line 15: | ||
=Text= | =Text= | ||
{{#Wiki_filter:ES-301 Transient and Event Checklist Form ES-301-5 | {{#Wiki_filter:ES-301 Transient and Event Checklist Form ES-301-5 Facility: Monticello Date of Exam: 01/28/13 Operating Test Number: MNGP 2013301 A | ||
01/28/ | P P | ||
: 1. Check the applicant level and enter the operating test number and Form ES | L I | ||
-D-1 event numbers for each event type; TS are not applicable for RO applicants. ROs must serve in both the | C A | ||
-the-controls (ATC) | N T | ||
and | E V | ||
-of-plant (BOP) | E N | ||
-for-1 basis. 3. Whenever practical, both instrument and component malfunctions should be included; only those that require verifiable actions that provide insight to the | T T | ||
Y P | |||
E Scenarios for Crew 1 1 | |||
2 3 | |||
4 (SPARE) | |||
T O | |||
T A | |||
L M | |||
I N | |||
I M | |||
U M(*) | |||
CREW POSITION CREW POSITION CREW POSITION CREW POSITION S | |||
R O | |||
A T | |||
C B | |||
O P | |||
S R | |||
O A | |||
T C | |||
B O | |||
P S | |||
R O | |||
A T | |||
C B | |||
O P | |||
S R | |||
O A | |||
T C | |||
B O | |||
P R | |||
I U | |||
Crew 1 RO 1 RX 2 | |||
1 1 | |||
NOR 2 | |||
1 2 | |||
1 I/C 2 4 3 5 6 3 4 7 | |||
4 MAJ 7 | |||
7 6 | |||
3 2 | |||
TS 0 | |||
0 Crew 1 RO 2 RX 4 | |||
1 1 | |||
NOR 1 | |||
1 1 | |||
I/C 3 4 2 5 7 5 | |||
4 MAJ 7 | |||
6 2 | |||
2 TS 0 | |||
0 Crew 1 SRO-I 1 RX 1 | |||
4 2 | |||
1 NOR 1 | |||
1 1 | |||
I/C 4 8 2 3 4 5 7 7 | |||
4 MAJ 7 | |||
8 2 | |||
2 TS 4 5 2 | |||
2 Crew 1 SRO-U RX 2 | |||
1 2 | |||
0 NOR 1 | |||
2 2 | |||
1 I/C 2 3 4 5 3 4 5 6 8 9 | |||
2 MAJ 7 | |||
7 2 | |||
1 TS 1 2 4 5 4 | |||
2 Instructions: | |||
: 1. | |||
Check the applicant level and enter the operating test number and Form ES-D-1 event numbers for each event type; TS are not applicable for RO applicants. ROs must serve in both the at-the-controls (ATC) and balance-of-plant (BOP) positions. Instant SROs must serve in both the SRO and the ATC positions, including at least two instrument or component (I/C) malfunctions and one major transient, in the ATC position. If an Instant SRO additionally serves in the BOP position, one I/C malfunction can be credited toward the two I/C malfunctions required for the ATC position. | |||
: 2. | |||
Reactivity manipulations may be conducted under normal or controlled abnormal conditions (refer to Section D.5.d) but must be significant per Section C.2.a of Appendix D. (*) Reactivity and normal evolutions may be replaced with additional instrument or component malfunctions on a 1-for-1 basis. | |||
: 3. | |||
Whenever practical, both instrument and component malfunctions should be included; only those that require verifiable actions that provide insight to the applicants competence count toward the minimum requirements specified for the applicants license level in the right-hand columns. | |||
the minimum requirements specified for the | ES-301 Transient and Event Checklist Form ES-301-5 Facility: Monticello Date of Exam: 01/28/13 Operating Test Number: MNGP 2013301 A | ||
-hand columns. | P P | ||
L I | |||
C A | |||
N T | |||
E V | |||
E N | |||
T T | |||
Y P | |||
E Scenarios for Crew 2 1 | |||
2 3 | |||
4 (SPARE) | |||
T O | |||
T A | |||
L M | |||
I N | |||
I M | |||
U M(*) | |||
CREW POSITION CREW POSITION CREW POSITION CREW POSITION S | |||
R O | |||
A T | |||
C B | |||
O P | |||
S R | |||
O A | |||
T C | |||
B O | |||
P S | |||
R O | |||
A T | |||
C B | |||
O P | |||
S R | |||
O A | |||
T C | |||
B O | |||
P R | |||
I U | |||
Crew 2 RO 3 RX 4 | |||
1 1 | |||
NOR 1 | |||
2 2 | |||
1 I/C 3 4 3 5 6 2 5 7 8 | |||
4 MAJ 7 | |||
7 6 | |||
3 2 | |||
TS 0 | |||
0 Crew 2 SRO-I 2 RX 2 | |||
1 2 | |||
1 NOR 2 | |||
1 2 | |||
1 I/C 2 4 3 4 5 6 8 3 4 9 | |||
4 MAJ 7 | |||
7 6 | |||
3 2 | |||
TS 4 5 2 | |||
2 Crew 2 SRO-I 3 RX 2 | |||
1 4 | |||
3 1 | |||
NOR 1 | |||
1 2 | |||
1 I/C 2 3 4 5 4 8 2 3 4 5 7 11 4 | |||
MAJ 7 | |||
7 8 | |||
3 2 | |||
TS 1 2 4 5 4 | |||
2 Instructions: | |||
: 4. | |||
Check the applicant level and enter the operating test number and Form ES-D-1 event numbers for each event type; TS are not applicable for RO applicants. ROs must serve in both the at-the-controls (ATC) and balance-of-plant (BOP) positions. Instant SROs must serve in both the SRO and the ATC positions, including at least two instrument or component (I/C) malfunctions and one major transient, in the ATC position. If an Instant SRO additionally serves in the BOP position, one I/C malfunction can be credited toward the two I/C malfunctions required for the ATC position. | |||
: 5. | |||
Reactivity manipulations may be conducted under normal or controlled abnormal conditions (refer to Section D.5.d) but must be significant per Section C.2.a of Appendix D. (*) Reactivity and normal evolutions may be replaced with additional instrument or component malfunctions on a 1-for-1 basis. | |||
: 6. | |||
Whenever practical, both instrument and component malfunctions should be included; only those that require verifiable actions that provide insight to the applicants competence count toward the minimum requirements specified for the applicants license level in the right-hand columns. | |||
ES-301 Transient and Event Checklist Form ES-301-5 | ES-301 Transient and Event Checklist Form ES-301-5 Facility: Monticello Date of Exam: 01/28/13 Operating Test Number: MNGP 2013301 A | ||
01/28/ | P P | ||
: | L I | ||
-D-1 event numbers for each event type; TS are not applicable for RO applicants. ROs must serve in both the | C A | ||
-the-controls (ATC) | N T | ||
and | E V | ||
-of-plant (BOP) | E N | ||
: | T T | ||
-for-1 basis. | Y P | ||
-hand columns. | E Scenarios for Crew 3 1 | ||
2 3 | |||
4 (SPARE) | |||
T O | |||
T A | |||
L M | |||
I N | |||
I M | |||
U M(*) | |||
CREW POSITION CREW POSITION CREW POSITION CREW POSITION S | |||
R O | |||
A T | |||
C B | |||
O P | |||
S R | |||
O A | |||
T C | |||
B O | |||
P S | |||
R O | |||
A T | |||
C B | |||
O P | |||
S R | |||
O A | |||
T C | |||
B O | |||
P R | |||
I U | |||
Crew 3 RO 4 RX 4 | |||
1 1 | |||
NOR 1 | |||
2 2 | |||
1 I/C 3 4 3 5 6 2 5 7 8 | |||
4 MAJ 7 | |||
7 6 | |||
3 2 | |||
TS 0 | |||
0 Crew 3 SRO-I 4 RX 2 | |||
1 2 | |||
1 NOR 2 | |||
1 2 | |||
1 I/C 2 4 3 4 5 6 8 3 4 9 | |||
4 MAJ 7 | |||
7 6 | |||
3 2 | |||
TS 4 5 2 | |||
2 Crew 3 SRO-I 5 RX 2 | |||
1 4 | |||
3 1 | |||
NOR 1 | |||
1 2 | |||
1 I/C 2 3 4 5 4 8 2 3 4 5 7 11 4 | |||
MAJ 7 | |||
7 8 | |||
3 2 | |||
TS 1 2 4 5 4 | |||
2 Instructions: | |||
: 7. | |||
Check the applicant level and enter the operating test number and Form ES-D-1 event numbers for each event type; TS are not applicable for RO applicants. ROs must serve in both the at-the-controls (ATC) and balance-of-plant (BOP) positions. Instant SROs must serve in both the SRO and the ATC positions, including at least two instrument or component (I/C) malfunctions and one major transient, in the ATC position. If an Instant SRO additionally serves in the BOP position, one I/C malfunction can be credited toward the two I/C malfunctions required for the ATC position. | |||
: 8. | |||
Reactivity manipulations may be conducted under normal or controlled abnormal conditions (refer to Section D.5.d) but must be significant per Section C.2.a of Appendix D. (*) Reactivity and normal evolutions may be replaced with additional instrument or component malfunctions on a 1-for-1 basis. | |||
: 9. | |||
Whenever practical, both instrument and component malfunctions should be included; only those that require verifiable actions that provide insight to the applicants competence count toward the minimum requirements specified for the applicants license level in the right-hand columns. | |||
ES-301 Transient and Event Checklist Form ES-301-5 | ES-301 Transient and Event Checklist Form ES-301-5 Facility: Monticello Date of Exam: 01/28/13 Operating Test Number: MNGP 2013301 A | ||
01/28/ | P P | ||
L I | |||
C A | |||
N T | |||
E V | |||
E N | |||
T T | |||
Y P | |||
E Spare Scenario 1 | |||
2 3 | |||
4 (SPARE) | |||
T O | |||
: 10. Check the applicant level and enter the operating test number and Form ES | T A | ||
-D-1 event numbers for each event type; TS are not applicable for RO applicants. ROs must serve in both the | L M | ||
-the-controls (ATC) | I N | ||
and | I M | ||
-of-plant (BOP) | U M(*) | ||
: 11. Reactivity manipulations may be conducted under normal or controlled abnormal conditions (refer to Section D.5.d) but must be significant per Section C.2.a of Appendix D. | CREW POSITION CREW POSITION CREW POSITION CREW POSITION S | ||
-for-1 basis. 12. Whenever practical, both instrument and component malfunctions should be included; only those that require verifiable actions that provide insight to the | R O | ||
-hand columns.}} | A T | ||
C B | |||
O P | |||
S R | |||
O A | |||
T C | |||
B O | |||
P S | |||
R O | |||
A T | |||
C B | |||
O P | |||
S R | |||
O A | |||
T C | |||
B O | |||
P R | |||
I U | |||
RO SRO-I SRO-U RX 1 | |||
1 0 | |||
NOR 1 | |||
1 1 | |||
1 I/C 3 4 7 4 4 | |||
2 MAJ 6 | |||
2 2 | |||
1 TS 0 | |||
2 2 | |||
RO SRO-I SRO-U RX 4 | |||
1 1 | |||
0 NOR 1 | |||
1 1 | |||
I/C 2 5 4 | |||
4 2 | |||
MAJ 6 | |||
2 2 | |||
1 TS 0 | |||
2 2 | |||
RO SRO-I SRO-U RX 4 | |||
1 1 | |||
0 NOR 1 | |||
1 1 | |||
1 I/C 2 3 4 5 7 4 | |||
4 2 | |||
MAJ 6 | |||
2 2 | |||
1 TS 2 3 0 | |||
2 2 | |||
Instructions: | |||
: 10. | |||
Check the applicant level and enter the operating test number and Form ES-D-1 event numbers for each event type; TS are not applicable for RO applicants. ROs must serve in both the at-the-controls (ATC) and balance-of-plant (BOP) positions. Instant SROs must serve in both the SRO and the ATC positions, including at least two instrument or component (I/C) malfunctions and one major transient, in the ATC position. If an Instant SRO additionally serves in the BOP position, one I/C malfunction can be credited toward the two I/C malfunctions required for the ATC position. | |||
: 11. | |||
Reactivity manipulations may be conducted under normal or controlled abnormal conditions (refer to Section D.5.d) but must be significant per Section C.2.a of Appendix D. (*) Reactivity and normal evolutions may be replaced with additional instrument or component malfunctions on a 1-for-1 basis. | |||
: 12. | |||
Whenever practical, both instrument and component malfunctions should be included; only those that require verifiable actions that provide insight to the applicants competence count toward the minimum requirements specified for the applicants license level in the right-hand columns.}} | |||
Latest revision as of 10:55, 11 January 2025
| ML13056A609 | |
| Person / Time | |
|---|---|
| Site: | Monticello |
| Issue date: | 01/29/2013 |
| From: | Mcneil D NRC/RGN-III/DRS/OLB |
| To: | |
| References | |
| Download: ML13056A609 (4) | |
Text
ES-301 Transient and Event Checklist Form ES-301-5 Facility: Monticello Date of Exam: 01/28/13 Operating Test Number: MNGP 2013301 A
P P
L I
C A
N T
E V
E N
T T
Y P
E Scenarios for Crew 1 1
2 3
4 (SPARE)
T O
T A
L M
I N
I M
U M(*)
CREW POSITION CREW POSITION CREW POSITION CREW POSITION S
R O
A T
C B
O P
S R
O A
T C
B O
P S
R O
A T
C B
O P
S R
O A
T C
B O
P R
I U
Crew 1 RO 1 RX 2
1 1
NOR 2
1 2
1 I/C 2 4 3 5 6 3 4 7
4 MAJ 7
7 6
3 2
TS 0
0 Crew 1 RO 2 RX 4
1 1
NOR 1
1 1
I/C 3 4 2 5 7 5
4 MAJ 7
6 2
2 TS 0
0 Crew 1 SRO-I 1 RX 1
4 2
1 NOR 1
1 1
I/C 4 8 2 3 4 5 7 7
4 MAJ 7
8 2
2 TS 4 5 2
2 Crew 1 SRO-U RX 2
1 2
0 NOR 1
2 2
1 I/C 2 3 4 5 3 4 5 6 8 9
2 MAJ 7
7 2
1 TS 1 2 4 5 4
2 Instructions:
- 1.
Check the applicant level and enter the operating test number and Form ES-D-1 event numbers for each event type; TS are not applicable for RO applicants. ROs must serve in both the at-the-controls (ATC) and balance-of-plant (BOP) positions. Instant SROs must serve in both the SRO and the ATC positions, including at least two instrument or component (I/C) malfunctions and one major transient, in the ATC position. If an Instant SRO additionally serves in the BOP position, one I/C malfunction can be credited toward the two I/C malfunctions required for the ATC position.
- 2.
Reactivity manipulations may be conducted under normal or controlled abnormal conditions (refer to Section D.5.d) but must be significant per Section C.2.a of Appendix D. (*) Reactivity and normal evolutions may be replaced with additional instrument or component malfunctions on a 1-for-1 basis.
- 3.
Whenever practical, both instrument and component malfunctions should be included; only those that require verifiable actions that provide insight to the applicants competence count toward the minimum requirements specified for the applicants license level in the right-hand columns.
ES-301 Transient and Event Checklist Form ES-301-5 Facility: Monticello Date of Exam: 01/28/13 Operating Test Number: MNGP 2013301 A
P P
L I
C A
N T
E V
E N
T T
Y P
E Scenarios for Crew 2 1
2 3
4 (SPARE)
T O
T A
L M
I N
I M
U M(*)
CREW POSITION CREW POSITION CREW POSITION CREW POSITION S
R O
A T
C B
O P
S R
O A
T C
B O
P S
R O
A T
C B
O P
S R
O A
T C
B O
P R
I U
Crew 2 RO 3 RX 4
1 1
NOR 1
2 2
1 I/C 3 4 3 5 6 2 5 7 8
4 MAJ 7
7 6
3 2
TS 0
0 Crew 2 SRO-I 2 RX 2
1 2
1 NOR 2
1 2
1 I/C 2 4 3 4 5 6 8 3 4 9
4 MAJ 7
7 6
3 2
TS 4 5 2
2 Crew 2 SRO-I 3 RX 2
1 4
3 1
NOR 1
1 2
1 I/C 2 3 4 5 4 8 2 3 4 5 7 11 4
MAJ 7
7 8
3 2
TS 1 2 4 5 4
2 Instructions:
- 4.
Check the applicant level and enter the operating test number and Form ES-D-1 event numbers for each event type; TS are not applicable for RO applicants. ROs must serve in both the at-the-controls (ATC) and balance-of-plant (BOP) positions. Instant SROs must serve in both the SRO and the ATC positions, including at least two instrument or component (I/C) malfunctions and one major transient, in the ATC position. If an Instant SRO additionally serves in the BOP position, one I/C malfunction can be credited toward the two I/C malfunctions required for the ATC position.
- 5.
Reactivity manipulations may be conducted under normal or controlled abnormal conditions (refer to Section D.5.d) but must be significant per Section C.2.a of Appendix D. (*) Reactivity and normal evolutions may be replaced with additional instrument or component malfunctions on a 1-for-1 basis.
- 6.
Whenever practical, both instrument and component malfunctions should be included; only those that require verifiable actions that provide insight to the applicants competence count toward the minimum requirements specified for the applicants license level in the right-hand columns.
ES-301 Transient and Event Checklist Form ES-301-5 Facility: Monticello Date of Exam: 01/28/13 Operating Test Number: MNGP 2013301 A
P P
L I
C A
N T
E V
E N
T T
Y P
E Scenarios for Crew 3 1
2 3
4 (SPARE)
T O
T A
L M
I N
I M
U M(*)
CREW POSITION CREW POSITION CREW POSITION CREW POSITION S
R O
A T
C B
O P
S R
O A
T C
B O
P S
R O
A T
C B
O P
S R
O A
T C
B O
P R
I U
Crew 3 RO 4 RX 4
1 1
NOR 1
2 2
1 I/C 3 4 3 5 6 2 5 7 8
4 MAJ 7
7 6
3 2
TS 0
0 Crew 3 SRO-I 4 RX 2
1 2
1 NOR 2
1 2
1 I/C 2 4 3 4 5 6 8 3 4 9
4 MAJ 7
7 6
3 2
TS 4 5 2
2 Crew 3 SRO-I 5 RX 2
1 4
3 1
NOR 1
1 2
1 I/C 2 3 4 5 4 8 2 3 4 5 7 11 4
MAJ 7
7 8
3 2
TS 1 2 4 5 4
2 Instructions:
- 7.
Check the applicant level and enter the operating test number and Form ES-D-1 event numbers for each event type; TS are not applicable for RO applicants. ROs must serve in both the at-the-controls (ATC) and balance-of-plant (BOP) positions. Instant SROs must serve in both the SRO and the ATC positions, including at least two instrument or component (I/C) malfunctions and one major transient, in the ATC position. If an Instant SRO additionally serves in the BOP position, one I/C malfunction can be credited toward the two I/C malfunctions required for the ATC position.
- 8.
Reactivity manipulations may be conducted under normal or controlled abnormal conditions (refer to Section D.5.d) but must be significant per Section C.2.a of Appendix D. (*) Reactivity and normal evolutions may be replaced with additional instrument or component malfunctions on a 1-for-1 basis.
- 9.
Whenever practical, both instrument and component malfunctions should be included; only those that require verifiable actions that provide insight to the applicants competence count toward the minimum requirements specified for the applicants license level in the right-hand columns.
ES-301 Transient and Event Checklist Form ES-301-5 Facility: Monticello Date of Exam: 01/28/13 Operating Test Number: MNGP 2013301 A
P P
L I
C A
N T
E V
E N
T T
Y P
E Spare Scenario 1
2 3
4 (SPARE)
T O
T A
L M
I N
I M
U M(*)
CREW POSITION CREW POSITION CREW POSITION CREW POSITION S
R O
A T
C B
O P
S R
O A
T C
B O
P S
R O
A T
C B
O P
S R
O A
T C
B O
P R
I U
RO SRO-I SRO-U RX 1
1 0
NOR 1
1 1
1 I/C 3 4 7 4 4
2 MAJ 6
2 2
1 TS 0
2 2
RO SRO-I SRO-U RX 4
1 1
0 NOR 1
1 1
I/C 2 5 4
4 2
MAJ 6
2 2
1 TS 0
2 2
RO SRO-I SRO-U RX 4
1 1
0 NOR 1
1 1
1 I/C 2 3 4 5 7 4
4 2
MAJ 6
2 2
1 TS 2 3 0
2 2
Instructions:
- 10.
Check the applicant level and enter the operating test number and Form ES-D-1 event numbers for each event type; TS are not applicable for RO applicants. ROs must serve in both the at-the-controls (ATC) and balance-of-plant (BOP) positions. Instant SROs must serve in both the SRO and the ATC positions, including at least two instrument or component (I/C) malfunctions and one major transient, in the ATC position. If an Instant SRO additionally serves in the BOP position, one I/C malfunction can be credited toward the two I/C malfunctions required for the ATC position.
- 11.
Reactivity manipulations may be conducted under normal or controlled abnormal conditions (refer to Section D.5.d) but must be significant per Section C.2.a of Appendix D. (*) Reactivity and normal evolutions may be replaced with additional instrument or component malfunctions on a 1-for-1 basis.
- 12.
Whenever practical, both instrument and component malfunctions should be included; only those that require verifiable actions that provide insight to the applicants competence count toward the minimum requirements specified for the applicants license level in the right-hand columns.