ML18075A064: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
 
(StriderTol Bot change)
 
(One intermediate revision by the same user not shown)
Line 1: Line 1:
{{Adams package
{{Adams package
| number = ML18075A064
| number = ML18075A064
| title = Waterford Steam Electric Station, Unit 3 - Transmittal of Final Waterford Steam Electric Station Accident Sequence Precursor Report (Licensee Event Report 382-2018-002)
| title = Transmittal of Final Waterford Steam Electric Station Accident Sequence Precursor Report (Licensee Event Report 382-2018-002)
| package contents =  
| release date = 03/22/2018
| package contents = {{Adams package content
| number = ML18075A076
| issue date = 03/22/2018
| title = Transmittal of Final Waterford Steam Electric Station, Unit 3, Accident Sequence Precursor Report (Licensee Event Report 382-2017-002)
| author name = Pulvirenti A
| author affiliation = NRC/NRR/DORL/LPLIV
| addressee name =
| addressee affiliation = Entergy Operations, Inc
| docket = 05000382
| license number = NPF-038
| contact person = Pulvirenti A L, NRR/DORL/LPLIV, 415-1390
| case reference number = LER 382-2017-002
| document type = Letter
| page count = 5
}}{{Adams package content
| number = ML18066A196
| issue date = 03/22/2018
| title = Final Accident Sequence Precursor Analysis-Waterford(Unit 3) Automatic Reactor Scram Due to the Failure of Fast Bus Transfer Relays to Automatically Transfer Station Loads to Offsite Power on a Main Generator Trip (LER 382-2017-002) Precurs
| author name = Gifford I
| author affiliation = NRC/RES/DRA/PRB
| addressee name =
| addressee affiliation =
| docket =
| license number =
| contact person =
| case reference number = LER 382-2017-002
| document report number = IR 2017011
| document type = Accident Sequence Precursor (ASP) Analysis, Final
| page count = 3
}}
}}
}}

Latest revision as of 18:44, 5 March 2020

Transmittal of Final Waterford Steam Electric Station Accident Sequence Precursor Report (Licensee Event Report 382-2018-002)
Date released: 03/22/2018 Download: ML18075A064


Transmittal of Final Waterford Steam Electric Station, Unit 3, Accident Sequence Precursor Report (Licensee Event Report 382-2017-002)
ML18075A076
Person / Time
Site: Waterford Entergy icon.png
Issue date: 03/22/2018
From: April Pulvirenti
Plant Licensing Branch IV
To:
Entergy Operations
Pulvirenti A L, NRR/DORL/LPLIV, 415-1390
References
LER 382-2017-002
Download: ML18075A076 (5)
Final Accident Sequence Precursor Analysis-Waterford(Unit 3) Automatic Reactor Scram Due to the Failure of Fast Bus Transfer Relays to Automatically Transfer Station Loads to Offsite Power on a Main Generator Trip (LER 382-2017-002) Precurs
ML18066A196
Person / Time
Issue date: 03/22/2018
From: Ian Gifford
NRC/RES/DRA/PRB
To:
References
LER 382-2017-002
Download: ML18066A196 (3)