{{Adams
#REDIRECT [[05000530/LER-1992-005-02, :on 921023,determined That 11 of 20 Main Steam Safety Valve as-found Relief Setpoints Out of TS 3.7.1.1 Tolerance from 921010-23.Possibly Caused by Setpoint Drift. Valves Will Be Removed & Shipped to Offsite Facility]]
| number = ML17306B427
| issue date = 04/24/1993
| title = LER 92-005-01:on 921023,determined That 11 of 20 Main Steam Safety Valve as-found Relief Setpoints Out of TS 3.7.1.1 Tolerance from 921010-23.Possibly Caused by Setpoint Drift. Valves Will Be Removed & Shipped to Offsite Facility
| author name = BRADISH T R
| author affiliation = ARIZONA PUBLIC SERVICE CO. (FORMERLY ARIZONA NUCLEAR
| addressee name =
| addressee affiliation =
| docket = 05000530
| license number =
| contact person =
| document report number = LER-92-005-02, LER-92-5-2, NUDOCS 9305050208
| package number = ML17306B426
| document type = LICENSEE EVENT REPORT (SEE ALSO AO,RO), TEXT-SAFETY REPORT
| page count = 16
}}
 