Response to SDAA Audit Question Question Number: A-4.5.2-3 Receipt Date: 12/04/2023 Question:
Provide, in the SDAA, updated schematics for the RVI with each line item from the provided table of materials labeled at least once in the schematics.
Response
The components in Table 4.5-2 that are not listed within FSAR Figure 3.9-1 through 3.9-4 are provided in the following drawings in the eRR:
ED-120820, Rev. 1, Upper Riser Assembly, Sheet 1 and 2
ED-121484, Rev. 0, Core Support Assembly
ED-121482, Rev. 1, Core Barrel Assembly, Sheet 1
ED-121891, Rev. 0, Lower Riser Assembly
ED-121881, Rev. 0, Lower Riser ICIGT Assembly
ED-121887, Rev. 0, CRA Guide Tube Assembly
ED-121882, Rev. 0, Lower Riser Shell Assembly, Sheet 1
ED-122049, Rev. 1, RPV Lower Subassembly, Sheet 1 For the bill of materials listed in ED-121484, the reference for the core barrel assembly should be ED-121482. The correction of this issue is being tracked by the NuScale corrective action program.
No changes to the SDAA are necessary.
NuScale Nonproprietary NuScale Nonproprietary