Regulatory Guide 1.100: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
(StriderTol Bot change)
 
(16 intermediate revisions by the same user not shown)
Line 1: Line 1:
{{Adams
{{Adams
| number = ML13350A292
| number = ML003740293
| issue date = 03/31/1976
| issue date = 06/30/1988
| title = Seismic Qualification of Electric Equipment for Nuclear Power Plant.
| title = (Task Ee 108-6), Seismic Qualification of Electric and Mechanical Equipment for Nuclear Power Plants
| author name =  
| author name =  
| author affiliation = NRC/OSD
| author affiliation = NRC/RES
| addressee name =  
| addressee name =  
| addressee affiliation =  
| addressee affiliation =  
Line 10: Line 10:
| license number =  
| license number =  
| contact person =  
| contact person =  
| document report number = RG-1.100
| document report number = RG-1.100, Revision 2
| document type = Regulatory Guide
| document type = Regulatory Guide
| page count = 2
| page count = 4
}}
}}
{{#Wiki_filter:U.S. NUCLEAR REGULATORY COMMISSIONMarch 1976* REGULATORY GUIDEOFFICE OF STANDARDS DEVELOPMENTREGULATORY GUIDE 1.100SEISMIC QUALIFICATION OF ELECTRICEQUIPMENT FOR NUCLEAR POWER PLANTS
{{#Wiki_filter:Revision 2
.4 o%"
U.S. NUCLEAR REGULATORY COMMISSION
June 1988
!REGULATORY GUIDE
OFFICE OF NUCLEAR REGULATORY RESEARCH
REGULATORY GUIDE 1.100
(Task EE 108-5)
SEISMIC QUALIFICATION OF ELECTRIC AND MECHANICAL EQUIPMENT
FOR NUCLEAR POWER PLANTS


==A. INTRODUCTION==
==A. INTRODUCTION==
basis earthquakes (OBEs). The standard contains require.ments indicated by the verbs "shall" and "must" andCriterion Ill, "Design Control," of Appendix B, recommendations indicated by "should.""Quality Assurance Criteria for Nuclear Power Plantsand Fuel Reprocessing Plants," to 10 CFR Part SO, The standard, which is an an s aid of IEEE"Licensing of. Production and Utilization Facilities," Std 323-1974, "IEEE Standard rA ua1 Class IErequires, among other things, that design control meas- Equipment for NuclearP rating Stations,ures provide for verifying the adequacy of design such as (endorsed, with excepti , ry Guide 1.89),by the performance of a suitable testing program. Where supplements part -e ethos required anda test program is used to verify the adequacy of a references the maa n r Std 323-1974.specific design feature, it is required to include suitablequalification testing of a prototype unit under the most CY POSITIONadverse design conditions. This regulatory guide de-scribes a method acceptable to the NRC staff for C 0 the requirements and recommen-complying with the Commission's regulations with re- dati by IEEE Std 344-19751 for conductingspect to verifying the adequacy of the seismic design of ii tion of Class IE Equipment is accept-k electric equipment for all types of nuclear power plants. en such qualification is performed i;iion with Regultory Guide 1.89, provides an
The Commission's regulations in 10 CFR Part 50,
"Domestic licensing of Production and Utilization Facilities," require that certain structures, systems, and components in a nuclear power plant be designed to withstand the effects of natural phenomena such as earthquakes and that design control measures such as testing be used to check the adequacy of design. This general requirement Is contained in Appendix A, "Gen eral Design Criteria for Nuclear Power Plants," to Part
50; in Criterion IIl, "Design Control," and Criterion XVII, "Quality Assurance Records," of Appendix B,  
"Quality Assurance Criteria for Nuclear Power Plants and Fuel Reprocessing Plants," to Part 50; and in Appendix A, "Seismic and Geologic Siting Criteria for Nuclear Power Plants," to Part 100, "Reactor Site Criteria."
In Appendix A to 10 CFR Part 100, Section VI,  
"Application to Engineering Design," requires that the nuclear power plant be designed so that, if the safe shutdown earthquake occurs, certain structures, systems, and components will remain functional. These safety related structures, systems, and components are those necessary to ensure (1) the integrity of the reactor cool ant pressure boundary, (2) the capability to shut down the reactor and maintain it in a safe condition, or (3)
the capability to prevent or mitigate the consequences of accidents that could result in offsite exposures comparable to the Part 100 guideline
 
====s. In Appendix A ====
to Part 100, Section VI(aX2) requires that structures, systems, and components of the nuclear power plant necessary for continued operation without-undue risk to the health and safety of the public be designed to re main functional and within applicable. stress and defor mation limits when subjected to the effects of the vibratory motion of an operating basis earthquake in combination with normal operating loads. The engineer-'
Ing method used to ensure that the required safety'
functions are maintained during and after the vibratoryF
ground motion associated with the safe shutdown earth-'
quake or the operating basis earthquake must involve%
the use of either a suitable dynamic analysis or a suit able qualification test to demonstrate that structures,;
systems, and components can withstand the seismic and other concurrent loads.
 
This regulatory guide describes a method acceptable to the NRC staff for complying with NRC's regulations with respect to seismic qualification of electric and mechanical equipment.
 
The Advisory Committee on Reactor Safeguards has been consulted concerning this guide and has concurred in the regulatory position.
 
Any information collection activities mentioned in this regulatory guide are contained as requirements in
10 CFR Parts 50 or 100, which provide the regulatory basis for this guide. The information collection require ments in 10 CFR Parts 50 and 100 have been cleared under OMB Clearance Nos. 3150-0011 and 3150-0093, respectively.


==B. DISCUSSION==
==B. DISCUSSION==
a ate basis for complying with design verificationequirements of Criterion Ill of Appendix B to 10 CFRIEEE Std 344-1975' (revision of EeisE t 50 with respect to verifying the seismic adequacy of344-;971), "IEEE Recommended Practi f is electric equipment, subject to the following:Qualification of Class I E Equipment for ,liar werGenerating Stations," dated January 3 , was 1. As indicated in Section 5.3, "Static Coefficientprepared by Working Group 2.5 (Seismic Q ication) Analysis," a static coefficient of 1.5 is used forof Subcommittee 2 (Equip t Quabfication) of the equipment analysis to take "nto account the effects ofInstitute of Electrical ant eU onics Engineers (IEEE) both multifrequency excitation and multimode me-Nuclear Power Engineeri W ee, and was subse- sponse. The use of 1 .5 as a static coefficient should notquently approved Ue Eftandards Board on be considered acceptable unless justified by analysis.December 20. 19) "Basis: There is no adequate evidence presented inThe p sio s standard include principles, Section 5.3 to substantiate the validity of a staticprocedure met o s of seismic qualification which,when satis will confirm the adequacy of theequipment de for the performance of Class IE 'IEEE Std 344-1975. "IEEE Recommended Practices forfunctions during and after the time the equipm,.nt is Seismic Qualification of'Class IE Equipment for Nuclear PowerGenerating Stations." Copies may be obtained from thesubjected to the forces resulting from one safe shutdown Institute of Electrical and Electronics Engineers, United Engioearthquake (SSE) preceded by a number of operating neering Center. 345 Eait 47th Street. New York, N.Y. 10017.USNRC REGULATORY GUIDES Comments ehould be sent to the Secretary of the Commission. U.S. NuclateReguletory Guides arm sesued to describe end make available to the public Regulattor Commission, Wash'ington. D.C. :SS. Attention: Oickellng andmethods acceptable to the NRC *fail of implementing specific parts of the S er*vIr Section.Commission s regulal.ons. to detineate Itchnoques used by the staff in evelu The guides are Isue in Ihe followin van broad dlslons-eling specific problems or postulated accidents. or to provide guidance to sppirtcents Regulatory Gudo$ arm not gublslitUtes lot requultions. and compliance I Power qeReactor 4S Prod-petswith them is not required Methods and solutlons different from those set out in 2 Research and Test Realtors ?. Transportationthegudew.l bsacceplotbla*f they provides be,.i to, the findng$ requs.tleto 3 Fuetl end Motorists Facilities i. Occupationall 5elththe isuance or cnni~nuance of a permit oa hC eOeft by the Comm,,uion 4. and Siting 9. Antitrust RAevlewComment, end suggestions lot *mprOviments on these guides are encouraged S PandPlant Protection 10. Oenaralei &!I times an d gu ide l wlI be revised. as appropriate. to accommodate eOrnmen ,nd to lletect nte , hlonalilon or eapeieonco However. comments on Copi.es of pubilished guides m ry be obtained by wlitten request Indicating 'heth,s ,.ide. ,I received within shout two months alter i1t issuance, will be pae divisions deeired to the U.S Nuclet Regulatory Commission. Washington. D.C.Itcute ,y I utsful sn eviluating the tie ed t O# An early V#*Vision 2 M6 , Attention Ditictor. Office at Sta dmdn Dar s eve lopm ertl.
IEEE
Std 344-1987, "Recommended Practice for Seismic Qualification of Class IE Equipment for Nuclear Power Generating Stations,"* was prepared by Working Group 2.5 (Seismic Qualification) of Subcommittee 2 (Equipment Qualification) of the Institute of Electrical  
*Copies may be obtained from the Institute of Eectdlcal and Electronics Engineers, IEEE Service Center, "S4 Hoes Lane, P.O. Box 1331, Plscataway, NJ 08855.
 
USNRC REGULATORY GUIDES  
The guides are Issued In the following ten broad divisions:
Regulatory Guides am Issued to describe and make available to the public methods acceptable to the NRC staff of Implementing
 
===1. Power Reactors ===
6. Products specific parts of the CommIsslon's regulations, to delineate tech-
2. Research and Test Reactors
7. Transportation nlques used bY the staff In evaluating specific problems or postu-
3. Fuels and Materials Facilities
8. Occupational Health lated accidents, or to provide guidance to applicant
 
====s. Regulatory ====
4. Environmental and Siting
9. Antitrust and Financial Review Guldes are not substitutes for regulations, and compliance witn
5. Materials and Plant Protection 10. General them Is not required. Methods and solutions different from those met out In the guides will be acceptable If they. provide a basis for the findingreusttoteIsacoroniunefapemtr Copies of issued guides may be purchased from the Government lningse eCommission.-
Printing Office at the current GPO price. Information on current GPO prices may be obtained by contacting the Superintendent of ThIs guide was Issued after consideration of comments received from Documents. U.S. Government Printing Office, Post Office Box the public. Comments and suggestions for Improvements In these  
37082. Washington. DC 20013-7082. telephone (202)275-2060 or guides are encouraged at all times, and guides will be revised, as  
(202)275-2171.
 
apiropriate, to accommodate comments and to reflect new Informa n or experience.
 
Issued guides may also be purchased from the National Technical Written comments may be submitted to the Rules and Procedures Information Service on a standing order basis. Details on this Branch.
 
DRR
ADM,  
U.S.


coefficient of 1.5, or one greater or less than 1.5, in itsapplication to equipment analysis.2. Section 6.6.2.1, "Derivation of Test Input Mo-tion," (concerning single frequency test input motion)states that, for equipment with more than orn predomi-nant frequency, the shake table motion should producea test response spectrum (TRS) acceleration at the testfrequencies equal to 1.5 times the acceleration given bythe specified required response spectrum (RRS) or less ifjustified. The section also states that the TRS need notenvelop the RRS provided the factor of 1.5 is used. Theuse of a factor of 1.5 and the concept that the TRS neednot envelop the RRS should not, in the absence ofjustification, be considered acceptable.Basis: These provisions violate the general require-ments stated in Section 6.6.1 of the standard forjustifiable test input.3. In the absence of justification, those portions ofSection 6.6.2.5, "Sine Sweep Test," which indicate that,for qualifying equipment using the sine sweep test input,the TRS must envelop the RRS according to the criteriadescribed in Section 6.6.2 and 6.6.2.1 should not beconsidered acceptable.,Basis: Sections 6.6.2 and 6.6.2.1 do not providespecific guidelines concerning a justfliable methodologyto define the TRS for a sweep input motion andtherefore violate the general requirements stated inSection 6.6.1 for a justifiable test input.4. The requirements given in Section 8, "Documenta-tion," should be supplemented by the following:8.6 Malfunction Data.If a malfunction -is defined in Section 2, "Defini-tions," Ls experienced during any test, the effect of thatmalfunction should be determined and documented inthe test report.Basis: This Is a logical extention of &'ction 8,"Documentation," and provides added emphasis on theneed to document all malfunctions that might result Inconsequences adverse to safety.
Nuclear Regulatory Commission, service may be obtained by writing NTIS. 5285 Port Royal Road, Washington. DE 20555.
 
Springfield, VA 22161.
 
and Electronics Engineers (IEEE) Nuclear Power Engi neering Committee, and was subsequently approved by the IEEE Standards Board on June 11, 1987.
 
The IEEE standard includes principles, procedures, and methods of seismic qualification that, when satis fied, will confirm the adequacy of the equipment design for the performance of safety functions before, during, and after the time the safety-related equipment is subjected to high stresses resulting from design basis events. For this guide, the design basis events are the loadings imposed by seismic events: the operating basis earthquake (OBE) and the safe shutdown earthquake (SSE). It is also necessary to combine other dynamic or vibratory loads as part of seismic qualification. It is recognized that hydrodynamic loads have their primary energy content in a frequency range greater than that of seismic vibrations; however, they are a part of the inplant equipment aging process, along with other non seismic vibration loads, and therefore should be con sidered in seismic testin&
Revision I of this guide was issued in August 1977.
 
Since then, several new technical issues have arisen, such as treatment of hydrodynamic loads, the limits of generic testing, the treatment of rattling, methods of qualifying line-mounted devices, and the use of actual seismic experience data bases to qualify identical or similar equipment. These issues are covered by IEEE
Std 344-1987, which reflects the state-of-the-art tech nology. Further, the NRC has extended the application of this standard to the qualification of mechanical equipment on an interim basis. In extending the applica tion of IEEE Std 344-1987 to mechanical equipment, the NRC staff recognizes that there are differences in qualification methods for electric and mechanical equipment.
 
Specifically, qualification of mechanical equipment by analysis is permitted when such equip ment can be modeled to adequately predict its response.
 
The American Society of Mechanical Engineers is cur rently developing a standard for seismic qualification of mechanical equipment. Upon publication of this stan dard, the NRC staff will review it for suitability for endorsement by a revision to this regulatory guide.
 
This regulatory guide covers two categories of equip ment: (1)
safety-related electric (Class IE) equipment.
 
and safety-related mechanical equipment, and (2)- non safety-related equipment whose failure can prevent the satisfactory accomplishment of safety functions. Exam ples of mechanical equipment within the scope of this guide are valves, valve operators, pumps, compressors, chillers, air handlers, fans, blowers, fuel rod assemblies, and control rod drive mechanisms.
 
IEEE Std 344-1987 recognizes the use of justified experience data as a method for seismic qualification.
 
This method of qualification will be evaluated by the NRC staff on a case-by-case basis.
 
IEEE' Std 344-1987 references other standards that contain valuable information. Those referenced standards not endorsed by a regulatory guide or incorporated intoK
the regulations, if used, are to be used in a manner consistent with current regulations.
 
==C. REGULATORY POSITION==
The procedures described by IEEE Std 344-1987,  
"Recommended Practice for Seismic Qualification of Class IE Equipment for Nuclear Power Generating Stations," are acceptable to the NRC staff for satisfying the Commission's regulations pertaining to seismic qualification of electric and mechanical equipment subject to the following:
For mechanical equipment, thermal distortion effects on operability should be considered, and loads imposed by the attached piping should also be accounted for.
 
If dynamic testing of a pump or a valve assembly is impracticable, static testing of the assembly is acceptable provided that (1) the end loading& are applied and are equal to or greater than postulated event loads, (2) all dynamic amplification effects are accounted for, (3) the component is in the operating mode during and after the application of loads, and (4) an adequate analysis is made to show the validity of the static application of loads.


==D. IMPLEMENTATION==
==D. IMPLEMENTATION==
The purpose of this section is to provide informationto applicants regarding the NRC staff's plans for usingthis regulatory guide.Except in those cases in which the applicant proposesan acceptable alternative method for complying withspecified portions of the Commission's regulations, themethod described herein will be used in the evaluationof submittals for construction permit applicationsdocketed after November 15, 1976, uldess this guide isrevised as a result of suggestions from the public oradditional staff review.If an applicant wishes to use this regulatory guide indeveloping submittals for applications docketed on orbefore November 15, 1976, the pertinent portions ofthe application will be evaluated on the basis of thkiguide..10(I-bi0.z0~in00I- UU'z8UitfJ C12uwI
The purpose of this section is to provide information to applicants and licensees regarding the NRC staff's plans for using this regulatory guide.
}}
 
Except in those cases in which the applicant or licensee proposes an acceptable alternative method for complying with specified portions of the Commission's regulations, the methods described herein will be used in the evaluation of seismic qualification of electric and mechanical equipment for the following nuclear power plants:
I. Plants for which the construction permit is issued after June 30, 1988,
2. Plants for which the operating license application is docketed after December 30, 1988,  
3. Plants for which the applicant or licensee voluntarily commits to the provisions of this guide.
 
1.100-2
4
 
VALUE/IMPACT STATEMENT
BACKGROUND
IEEE Std 344-1975, "Recommended Practice for Seismic Qualification of Class IE Equipment for Nuclear Power Generating Stations," was approved by the IEEE
in January 1975. In August 1977, the NRC staff issued Revision 1 to Regulatory Guide 1.100, which endorsed IEEE Std 344-1975, subject to four exceptions. Since then the staff has worked with the IEEE in developing IEEE Std 344-1987. As a result of these efforts, the exceptions to IEEE Std 344-1975 have been satisfacto rily resolved.
 
IEEE Std 344-1987 also addresses several recent technical issues, for example, treatment of hydrody namic loads, the limits of generic testing,, the treatment of rattling, methods of qualifying line-mounted devices, and the use of actual seismic experience data bases to qualify identical or similar equipment. IEEE Std 344
1987 thus reflects the state-of-the-art technology.
 
Issuance of Revision 2 is consistent with the NRC
policy of evaluating the latest versions of national standards in terms of their suitability for endorsement by regulatory guides.
 
SUBSTANTIVE CHANGES
IEEE Std 344-1987 applies to seismic and dynamic qualification of Class IE (safety-related electric) equip ment. The nuclear industry has used this standard for seismic qualification of mechanical equipment as well.
 
The NRC staff recognizes this fact and intends to
"extend the application of this standard to seismic qualification of mechanical equipment by this regulatory guide. Specifically, this regulatory guide coven two categories of equipment: (1) safety-related electric (Class IE) equipment and safety-related mechanical equipment, and (2) non-safety-related equipment whose failure can prevent the satisfactory accomplishment of safety func tions. The regulatory position provides guidance for qualification of mechanical equipment that is consistent with current NRC practice.
 
Regulatory Positions C.1 to C.4 in Revision 1 are not included in Revision 2 because they have been incorpo rated in IEEE Std 344-1987 as follows:
Regulatory Position in Rev. I of this Guide IEEE Std 344-1987 Section Number C.l
6.3 C.2
7.6.2.1 C.3
7.6.2.5 C.4
10.3.2(6)
VALUE
This guide endorses the latest version of a national standard and reflects the current state-of-the-art tech nology. The guide should also enhance the licensing process.
 
IMPACT
Although the scope of this revision has been ex tended to include seismic qualification of mechanical equipment, the requirements are consistent with NRC
current licensing practice. Thus, this regulatory guide does not impose any new requirements or costs on licensees or applicants.
 
1.100-3
 
UNITED STATES
NUCLEAR REGULATORY COMMISSION
WASHINGTON, D.C. 20555 OFFICIAL BUSINESS
PENALTY FOR PRIVATE USE, $300
FIRST CLASS MAIL
APOIAGE
I FEES PAID
USNRC
PERMIT N. G
111}}


{{RG-Nav}}
{{RG-Nav}}

Latest revision as of 02:06, 17 January 2025

(Task Ee 108-6), Seismic Qualification of Electric and Mechanical Equipment for Nuclear Power Plants
ML003740293
Person / Time
Issue date: 06/30/1988
From:
Office of Nuclear Regulatory Research
To:
References
RG-1.100, Revision 2
Download: ML003740293 (4)


Revision 2

.4 o%"

U.S. NUCLEAR REGULATORY COMMISSION

June 1988

!REGULATORY GUIDE

OFFICE OF NUCLEAR REGULATORY RESEARCH

REGULATORY GUIDE 1.100

(Task EE 108-5)

SEISMIC QUALIFICATION OF ELECTRIC AND MECHANICAL EQUIPMENT

FOR NUCLEAR POWER PLANTS

A. INTRODUCTION

The Commission's regulations in 10 CFR Part 50,

"Domestic licensing of Production and Utilization Facilities," require that certain structures, systems, and components in a nuclear power plant be designed to withstand the effects of natural phenomena such as earthquakes and that design control measures such as testing be used to check the adequacy of design. This general requirement Is contained in Appendix A, "Gen eral Design Criteria for Nuclear Power Plants," to Part

50; in Criterion IIl, "Design Control," and Criterion XVII, "Quality Assurance Records," of Appendix B,

"Quality Assurance Criteria for Nuclear Power Plants and Fuel Reprocessing Plants," to Part 50; and in Appendix A, "Seismic and Geologic Siting Criteria for Nuclear Power Plants," to Part 100, "Reactor Site Criteria."

In Appendix A to 10 CFR Part 100, Section VI,

"Application to Engineering Design," requires that the nuclear power plant be designed so that, if the safe shutdown earthquake occurs, certain structures, systems, and components will remain functional. These safety related structures, systems, and components are those necessary to ensure (1) the integrity of the reactor cool ant pressure boundary, (2) the capability to shut down the reactor and maintain it in a safe condition, or (3)

the capability to prevent or mitigate the consequences of accidents that could result in offsite exposures comparable to the Part 100 guideline

s. In Appendix A

to Part 100,Section VI(aX2) requires that structures, systems, and components of the nuclear power plant necessary for continued operation without-undue risk to the health and safety of the public be designed to re main functional and within applicable. stress and defor mation limits when subjected to the effects of the vibratory motion of an operating basis earthquake in combination with normal operating loads. The engineer-'

Ing method used to ensure that the required safety'

functions are maintained during and after the vibratoryF

ground motion associated with the safe shutdown earth-'

quake or the operating basis earthquake must involve%

the use of either a suitable dynamic analysis or a suit able qualification test to demonstrate that structures,;

systems, and components can withstand the seismic and other concurrent loads.

This regulatory guide describes a method acceptable to the NRC staff for complying with NRC's regulations with respect to seismic qualification of electric and mechanical equipment.

The Advisory Committee on Reactor Safeguards has been consulted concerning this guide and has concurred in the regulatory position.

Any information collection activities mentioned in this regulatory guide are contained as requirements in

10 CFR Parts 50 or 100, which provide the regulatory basis for this guide. The information collection require ments in 10 CFR Parts 50 and 100 have been cleared under OMB Clearance Nos. 3150-0011 and 3150-0093, respectively.

B. DISCUSSION

IEEE Std 344-1987, "Recommended Practice for Seismic Qualification of Class IE Equipment for Nuclear Power Generating Stations,"* was prepared by Working Group 2.5 (Seismic Qualification) of Subcommittee 2 (Equipment Qualification) of the Institute of Electrical

  • Copies may be obtained from the Institute of Eectdlcal and Electronics Engineers, IEEE Service Center, "S4 Hoes Lane, P.O. Box 1331, Plscataway, NJ 08855.

USNRC REGULATORY GUIDES

The guides are Issued In the following ten broad divisions:

Regulatory Guides am Issued to describe and make available to the public methods acceptable to the NRC staff of Implementing

1. Power Reactors

6. Products specific parts of the CommIsslon's regulations, to delineate tech-

2. Research and Test Reactors

7. Transportation nlques used bY the staff In evaluating specific problems or postu-

3. Fuels and Materials Facilities

8. Occupational Health lated accidents, or to provide guidance to applicant

s. Regulatory

4. Environmental and Siting

9. Antitrust and Financial Review Guldes are not substitutes for regulations, and compliance witn

5. Materials and Plant Protection 10. General them Is not required. Methods and solutions different from those met out In the guides will be acceptable If they. provide a basis for the findingreusttoteIsacoroniunefapemtr Copies of issued guides may be purchased from the Government lningse eCommission.-

Printing Office at the current GPO price. Information on current GPO prices may be obtained by contacting the Superintendent of ThIs guide was Issued after consideration of comments received from Documents. U.S. Government Printing Office, Post Office Box the public. Comments and suggestions for Improvements In these

37082. Washington. DC 20013-7082. telephone (202)275-2060 or guides are encouraged at all times, and guides will be revised, as

(202)275-2171.

apiropriate, to accommodate comments and to reflect new Informa n or experience.

Issued guides may also be purchased from the National Technical Written comments may be submitted to the Rules and Procedures Information Service on a standing order basis. Details on this Branch.

DRR

ADM,

U.S.

Nuclear Regulatory Commission, service may be obtained by writing NTIS. 5285 Port Royal Road, Washington. DE 20555.

Springfield, VA 22161.

and Electronics Engineers (IEEE) Nuclear Power Engi neering Committee, and was subsequently approved by the IEEE Standards Board on June 11, 1987.

The IEEE standard includes principles, procedures, and methods of seismic qualification that, when satis fied, will confirm the adequacy of the equipment design for the performance of safety functions before, during, and after the time the safety-related equipment is subjected to high stresses resulting from design basis events. For this guide, the design basis events are the loadings imposed by seismic events: the operating basis earthquake (OBE) and the safe shutdown earthquake (SSE). It is also necessary to combine other dynamic or vibratory loads as part of seismic qualification. It is recognized that hydrodynamic loads have their primary energy content in a frequency range greater than that of seismic vibrations; however, they are a part of the inplant equipment aging process, along with other non seismic vibration loads, and therefore should be con sidered in seismic testin&

Revision I of this guide was issued in August 1977.

Since then, several new technical issues have arisen, such as treatment of hydrodynamic loads, the limits of generic testing, the treatment of rattling, methods of qualifying line-mounted devices, and the use of actual seismic experience data bases to qualify identical or similar equipment. These issues are covered by IEEE Std 344-1987, which reflects the state-of-the-art tech nology. Further, the NRC has extended the application of this standard to the qualification of mechanical equipment on an interim basis. In extending the applica tion of IEEE Std 344-1987 to mechanical equipment, the NRC staff recognizes that there are differences in qualification methods for electric and mechanical equipment.

Specifically, qualification of mechanical equipment by analysis is permitted when such equip ment can be modeled to adequately predict its response.

The American Society of Mechanical Engineers is cur rently developing a standard for seismic qualification of mechanical equipment. Upon publication of this stan dard, the NRC staff will review it for suitability for endorsement by a revision to this regulatory guide.

This regulatory guide covers two categories of equip ment: (1)

safety-related electric (Class IE) equipment.

and safety-related mechanical equipment, and (2)- non safety-related equipment whose failure can prevent the satisfactory accomplishment of safety functions. Exam ples of mechanical equipment within the scope of this guide are valves, valve operators, pumps, compressors, chillers, air handlers, fans, blowers, fuel rod assemblies, and control rod drive mechanisms.

IEEE Std 344-1987 recognizes the use of justified experience data as a method for seismic qualification.

This method of qualification will be evaluated by the NRC staff on a case-by-case basis.

IEEE' Std 344-1987 references other standards that contain valuable information. Those referenced standards not endorsed by a regulatory guide or incorporated intoK

the regulations, if used, are to be used in a manner consistent with current regulations.

C. REGULATORY POSITION

The procedures described by IEEE Std 344-1987,

"Recommended Practice for Seismic Qualification of Class IE Equipment for Nuclear Power Generating Stations," are acceptable to the NRC staff for satisfying the Commission's regulations pertaining to seismic qualification of electric and mechanical equipment subject to the following:

For mechanical equipment, thermal distortion effects on operability should be considered, and loads imposed by the attached piping should also be accounted for.

If dynamic testing of a pump or a valve assembly is impracticable, static testing of the assembly is acceptable provided that (1) the end loading& are applied and are equal to or greater than postulated event loads, (2) all dynamic amplification effects are accounted for, (3) the component is in the operating mode during and after the application of loads, and (4) an adequate analysis is made to show the validity of the static application of loads.

D. IMPLEMENTATION

The purpose of this section is to provide information to applicants and licensees regarding the NRC staff's plans for using this regulatory guide.

Except in those cases in which the applicant or licensee proposes an acceptable alternative method for complying with specified portions of the Commission's regulations, the methods described herein will be used in the evaluation of seismic qualification of electric and mechanical equipment for the following nuclear power plants:

I. Plants for which the construction permit is issued after June 30, 1988,

2. Plants for which the operating license application is docketed after December 30, 1988,

3. Plants for which the applicant or licensee voluntarily commits to the provisions of this guide.

1.100-2

4

VALUE/IMPACT STATEMENT

BACKGROUND

IEEE Std 344-1975, "Recommended Practice for Seismic Qualification of Class IE Equipment for Nuclear Power Generating Stations," was approved by the IEEE

in January 1975. In August 1977, the NRC staff issued Revision 1 to Regulatory Guide 1.100, which endorsed IEEE Std 344-1975, subject to four exceptions. Since then the staff has worked with the IEEE in developing IEEE Std 344-1987. As a result of these efforts, the exceptions to IEEE Std 344-1975 have been satisfacto rily resolved.

IEEE Std 344-1987 also addresses several recent technical issues, for example, treatment of hydrody namic loads, the limits of generic testing,, the treatment of rattling, methods of qualifying line-mounted devices, and the use of actual seismic experience data bases to qualify identical or similar equipment. IEEE Std 344

1987 thus reflects the state-of-the-art technology.

Issuance of Revision 2 is consistent with the NRC

policy of evaluating the latest versions of national standards in terms of their suitability for endorsement by regulatory guides.

SUBSTANTIVE CHANGES

IEEE Std 344-1987 applies to seismic and dynamic qualification of Class IE (safety-related electric) equip ment. The nuclear industry has used this standard for seismic qualification of mechanical equipment as well.

The NRC staff recognizes this fact and intends to

"extend the application of this standard to seismic qualification of mechanical equipment by this regulatory guide. Specifically, this regulatory guide coven two categories of equipment: (1) safety-related electric (Class IE) equipment and safety-related mechanical equipment, and (2) non-safety-related equipment whose failure can prevent the satisfactory accomplishment of safety func tions. The regulatory position provides guidance for qualification of mechanical equipment that is consistent with current NRC practice.

Regulatory Positions C.1 to C.4 in Revision 1 are not included in Revision 2 because they have been incorpo rated in IEEE Std 344-1987 as follows:

Regulatory Position in Rev. I of this Guide IEEE Std 344-1987 Section Number C.l

6.3 C.2

7.6.2.1 C.3

7.6.2.5 C.4

10.3.2(6)

VALUE

This guide endorses the latest version of a national standard and reflects the current state-of-the-art tech nology. The guide should also enhance the licensing process.

IMPACT

Although the scope of this revision has been ex tended to include seismic qualification of mechanical equipment, the requirements are consistent with NRC

current licensing practice. Thus, this regulatory guide does not impose any new requirements or costs on licensees or applicants.

1.100-3

UNITED STATES

NUCLEAR REGULATORY COMMISSION

WASHINGTON, D.C. 20555 OFFICIAL BUSINESS

PENALTY FOR PRIVATE USE, $300

FIRST CLASS MAIL

APOIAGE

I FEES PAID

USNRC

PERMIT N. G

111