| title = Design, Testing, and Maintenance Criteria for Normal Ventilation Exhaust System Air Filtration and Adsorption Units of Light-Water-Cooled Nuclear Power Plants
| title = (Revision 2), Design, Inspection, and Testing Criteria for Air Filtration and Adsorption Units of Normal Atmosphere Cleanup Systems in Light-Water-Cooled Nuclear Power Plants
| author name =  
| author name =  
| author affiliation = NRC/RES
| author affiliation = NRC/RES
Line 9: Line 9:
| docket =  
| docket =  
| license number =  
| license number =  
| contact person =  
| contact person = Segala J
| case reference number = DG-1103
| document report number = RG-1.140
| document report number = RG-1.140
| document type = Regulatory Guide
| document type = Regulatory Guide
| page count = 8
| page count = 17
}}
}}
{{#Wiki_filter:U.S. NUCLEAR REGULATORY  
{{#Wiki_filter:Regulatory guides are issued to describe and make available to the public such information as methods acceptable to the NRC staff for implementing specific parts of the NRCs  regulations, techniques used by the staff in evaluating specific problems or postulated accidents, and data needed by the NRC staff in its review of applications for permits and licenses.  Regulatory guides are not substitutes for regulations, and compliance with them is not required.  Methods and solutions different from those set out in the guides will be acceptable if they provide a basis for the findings requisite to the issuance or continuance of a permit or license by the Commission.
COMMISSION
 
March 1978)REGULATORY  
This guide was issued after consideration of comments received from the public.  Comments and suggestions for improvements in these guides are encouraged at all times, and guides will be revised, as appropriate, to accommodate comments and to reflect new information or experience.  Written comments may be submitted to the Rules and Directives Branch, ADM, U.S. Nuclear Regulatory Commission, Washington, DC 20555-0001.
GUIDE OFFICE OF STANDARDS
 
DEVELOPMENT
Regulatory guides are issued in ten broad divisions:  1, Power Reactors; 2, Research and Test Reactors; 3, Fuels and Materials Facilities; 4, Environmental and Siting;
REGULATORY  
5, Materials and Plant Protection; 6, Products; 7, Transportation; 8, Occupational Health; 9, Antitrust and Financial Review; and 10, General.
GUIDE 1.140 DESIGN, TESTING, AND MAINTENANCE
 
CRITERIA FOR NORMAL VENTILATION
Single copies of regulatory guides (which may be reproduced) may be obtained free of charge by writing the Distribution Services Section, U.S. Nuclear Regulatory Commission, Washington, DC 20555-0001, or by fax to (301)415-2289, or by email to DISTRIBUTION@NRC.GOV.  Electronic copies of this guide are available on the internet at NRCs home page at <WWW.NRC.GOV> in the Reference Library under Regulatory Guides and through the Electronic Reading Room, as Accession Number ML011710150, along with other recently issued guides, at the same web site.
EXHAUST SYSTEM AIR FILTRATION  
 
AND ADSORPTION  
U.S. NUCLEAR REGULATORY COMMISSION               Revision 2 June 2001 REGULATORY
UNITS OF LIGHT-WATER-COOLED  
GUIDE
NUCLEAR POWER PLANTS  
OFFICE OF NUCLEAR REGULATORY RESEARCH
REGULATORY GUIDE 1.140
(Draft was issued as DG-1103)
DESIGN, INSPECTION, AND TESTING CRITERIA FOR
AIR FILTRATION AND ADSORPTION UNITS OF NORMAL
ATMOSPHERE CLEANUP SYSTEMS IN LIGHT-WATER-COOLED
NUCLEAR POWER PLANTS


==A. INTRODUCTION==
==A. INTRODUCTION==
General Design Criteria 60 and 61 of Appendix A,"General Design Criteria for Nuclear Power Plants," to 10 CFR Part 50, "Licensing of Production and Utilization Facilities," require that filtering systems be included in the nuclear power unit design to control suitably the release of radioactive materials in gase-ous effluents during normal reactor operation, includ-ing anticipated operational occurrences and fuel stor-age and handling operations.
This guide provides guidance and criteria acceptable to the NRC staff for meeting the NRC's regulations with regard to the design, inspection, and testing of air filtration and adsorption units installed in the normal atmosphere cleanup systems of light-water-cooled nuclear power plants.  This guide applies only to atmosphere cleanup systems designed to collect airborne radioactive materials during normal plant operation, including anticipated operational occurrences.  Therefore, in this guide these systems are referred to as normal atmosphere cleanup systems.  These normal atmosphere cleanup systems may consist of heaters and/or cooling coils, prefilters, high-efficiency particulate air (HEPA) filters, iodine adsorption units, fans, associated ductwork, dampers, and instrumentation.  The instrumentation covered by this guide is that used to measure air flow and differential pressure.
 
In Appendix A, "General Design Criteria for Nuclear Power Plants," to 10 CFR Part 50,
Domestic Licensing of Production and Utilization Facilities, General Design Criteria 60 and 61 require
 
1.140-2 that the nuclear power plant design include means to suitably control the release of radioactive materials in gaseous effluents during normal reactor operation, including anticipated operational occurrences and fuel storage and handling operations.  In addition, 10 CFR 50.34a, "Design Objectives for Equipment To Control Releases of Radioactive Material in Effluents -- Nuclear Power Reactors," and 10 CFR 50.36a, "Technical Specifications on Effluents from Nuclear Power Reactors," of 10 CFR Part 50 require that means be employed to ensure that release of radioactive material to unrestricted areas during normal reactor operation, including during expected operational occurrences, is kept as low as is reasonably achievable.
 
Appendix I, "Numerical Guides for Design Objectives and Limiting Conditions for Operation To Meet the Criterion As Low As Is Reasonably Achievable for Radioactive Material in Light-Water-Cooled Nuclear Power Reactor Effluents," to 10 CFR Part 50 provides guidance and numerical values for design objectives to help applicants for, and holders of, licenses for nuclear power plants meet the requirements of 10 CFR 50.34a and 50.36a.  Appendix I requires that each light-water-cooled nuclear power reactor unit not exceed an annual dose design objective of 15 mrem to any organ of any individual in an unrestricted area via all exposure pathways from airborne radioactive iodine and particulate releases.  Appendix I also requires that additional radwaste equipment be provided if the equipment has reasonably demonstrated technology and the cost-benefit ratio is favorable.


In addition, &sect;&sect;50.34a,"Design objectives for equipment to control releases of radioactive material in effluents-nuclear power reactors," and 50.36a, "Technical specifications on effluents from nuclear power reactors," of 10 CFR Part 50 require that means be employed to ensure that release of radioactive material to unrestricted are, during normal reactor. operation, including  operational occurrences, is kept as low as i sea: sonably achievable.
This guide does not apply to post-accident engineered-safety-feature (ESF) atmosphere cleanup systems that are designed to mitigate the consequences of postulated accidents.


Appendix I, "Numerical Guides for C Ob tives and Limiting Conditions for Oper .on tol eet the Criterion
Regulatory Guide 1.52, "Design, Inspection, and Testing Criteria for Air Filtration and Adsorption Units of Post-Accident Engineered-Safety-Feature Atmosphere Cleanup Systems in Light-Water- Cooled Nuclear Power Plants," provides guidance for these systems.
'As Low As Is Reasonabl le'for Radioactive Material in Light-Water-Coo ed Nu-clear Power Reactor Effluents," to 10 CFR Part 50 provides guidance and n al values for design objectives to help appl t and holders of, licenses for nuclear we ant feet the require-ments of &sect;&sect;50.34 .Appendix I requires that each light- er-co d nuclear power reactor unit not exce an ua ose design objective of 15 mrem to a n ny individual in an unre-stricted area all exposure pathways from airborne radioactive io and particulate releases.


Appendix I also requires that additional radwaste equipment be provided if the equipment has reasonably demon-strated technology and the cost-benefit ratio is favor-able.This guide presents methods ac j able to the NRC staff for implementing the Conxizition's regulations in 10 CFR Part 50 and in nl 'ndi $.A and I to 10 CFR Part 50 with regard to'b, desi,' testing, and maintenance criteria fo and adsorption units installed in thvqiOe, vation exhaust sys-tems of light-watepoo ed ch 5 lear power plants. This guide applies onlf-4.iCIosphere cleanup systems de-signed to co r dioactive materials during normal plant ptioi -'including anticipated opera-tional r d and addresses the atmosphere cleanup , including the various components a in the normal operating environment., e does not apply to postaccident
The guidance and criteria presented in this guide are not mandatory and licensees may choose not to change their licensing basis. Methods and solutions different from those set out in this guide will be acceptable when an applicant or licensee proposes an acceptable alternative method for complying with the specified portions of the NRCs regulations.
4e -dsafety-feature atmosphere cleanup sys-' at are designed to mitigate the consequences postulated accidents.


Regulatory Guide 1.52, Oh ". esign, Testing, and Maintenance Criteria for Post-.accident Engineered-Safety-Feature Atmosphere Cleanup System Air Filtration and Adsorption Units of Light-Water-Cooled Nuclear Power Plants," pro-vides guidance for these systems.
The information collections contained in this regulatory guide are covered by the requirements of 10 CFR Part 50, which were approved by the Office of Management and Budget, approval number 3150-0011. If a means used to impose an information collection does not display a currently valid OMB control number, the NRC may not conduct or sponsor, and a person is not required to respond to, the information collection.


==B. DISCUSSION==
==B. DISCUSSION==
Particulate filtration and radioiodine adsorption units are included in the design of the ventilation exhaust systems of light-water-coolc I nuclear power plants to reduce the quantities of raCractive mate-rials in gaseous effluents released fron. building or containment atmospheres during normal operation.
Particulate filtration and radioiodine adsorption units are included in the design of the normal atmosphere cleanup systems of light-water-cooled nuclear power plants to reduce the quantities of radioactive materials in gaseous effluents released from building or containment atmospheres during normal operation, including anticipated operational occurrence
 
====s. All such====
 
1.140-3 cleanup systems should be designed to operate continuously under normal environmental conditions.
 
In this guide, cleanup systems that should operate to meet the "as low as is reasonably achievable (ALARA)" guidelines of Appendix I to 10 CFR Part 50 inside the primary containment (recirculating units) are designated as "primary systems."  Primary systems generally include a containment cleanup system (kidney filtration system).  Systems that operate outside the primary containment are designated as "secondary systems."  Secondary systems generally include normal atmosphere cleanup systems servicing the reactor building, turbine building, radwaste building, auxiliary building, mechanical vacuum pump, main condenser air ejector, and any other release points that may contain particulate and gaseous radioiodine species.


including anticipated operational occurrences.
These normal atmosphere cleanup systems should be able to withstand normal environmental conditions such as inlet concentrations of radioactive iodine up to 10-6 &#xb5;Ci/cm3, relative humidity of the influent stream up to 100%, temperatures of the influent stream up to
125&deg;F (52&deg;C), and normal atmospheric pressure.  The system should be designed, inspected, and tested in such a manner that radiation levels of airborne radioactive material and radioiodine buildup on the adsorber do not degrade the performance of the filter system or any component.


All such cleanup systems should be designed to operate continuously under normal environmental conditions.
Normal atmosphere cleanup system heaters are designed to heat the influent stream to reduce its relative humidity before it reaches the filters and adsorbers.  HEPA filters are installed to remove particulate matter, which may be radioactive, and pass the air stream to the adsorber, which then removes gaseous iodine (elemental iodine and organic iodides) from the air stream.  A
HEPA filter or a medium efficiency postfilter (as defined in Section 5.3 of ASME N509-1989 (Ref. 1)) downstream from the adsorption units collects carbon fines and provides additional protection against particulate matter release in case of failure of the upstream HEPA filter bank.  It is not necessary to perform in-place leak testing on postfilters or HEPA filters downstream from the carbon adsorbers.  It is advantageous for the postfilters or HEPA filters downstream from the carbon adsorbers to be installed in separate housings or to be removed from the housing (for systems with a fan downstream from the housing) during in-place leak testing of the upstream HEPA filter.  This will contribute to the accuracy of the test results for the upstream HEPA filter.


In this guide, cleanup systems that should operate to meet the "as low as is reasonably achievable" guidelines of Appendix I to 10 CFR Part 50 inside the primary containment (recirculating units) are desig-USNRC REGULATORY
The arrangement of the ductwork and the transitions between the separate housings can provide a torturous path that will aid in mixing the challenge agent.  Removing the filters downstream from the carbon adsorbers will permit sampling downstream from the fan.  The fan will provide the necessary mixing for an accurate test and the absences of the postfilters or HEPA filters downstream from the carbon adsorbers will prevent the challenge aerosol from being removed from the air stream. The fan is the final item in a normal atmosphere cleanup system.
GUIDES Comments should be sent to the Secretary of the Comm muon.US.Nucl.ae Rq.u Regulatory Guides we Issued to desculbe and Make Mvailalit to the public methods latore Commitsion.


Washinto,.
Consideration should be given to installing prefilters upstream from the HEPA filters to reduce the particulate load and extend their service life.
O.C. 20?655. Attention Oocketng And  somptablit to the NRC staff of implementing specifi t pant of the Commision's Barnch.rtelatlint.


to used by the staff In evaluating sp"tific Problems The guides we issued in the following ten broad dowsont Or postulated aicidents, or to provide it. epplieants.
The environmental history of the facility will affect the performance of the normal atmosphere cleanup system.  Industrial contaminants, pollutants, temperature, and relative humidity contribute to the aging and weathering of filters and adsorbers and reduce their capability to perform their intended functions. Therefore, aging, weathering, and poisoning of these components, which may vary from site to site, need to be considered during design and operation.


Regulatory Guides are not sibstilutes for rsguilaions.
1.140-4 Average temperature and relative humidity also vary from site to site, and the potential buildup of moisture in the adsorber warrants equal design consideration.  The effects of these factors on the normal atmosphere cleanup system can be determined by a monitoring program.


and compliance with them is not required.
All components of the normal atmosphere cleanup system need to be designed for reliable performance under the expected operating conditions.  Initial testing and proper maintenance are primary factors in ensuring the reliability of the system.  Consideration during the design phase of problems of system maintenance can contribute significantly to the reliability of the system by increasing the ease of such maintenance.  A layout that provides accessibility and sufficient working space to safely and efficiently perform the required maintenance functions is of particular importance in the design.  Periodic inspection and testing during operation to verify the efficiency of the components is another important means of ensuring reliability.  Built-in features that will facilitate convenient in-place testing are important in system design.


I. Power Reactors 6. Products Methods end tOlutions different from thaw set out In the guitde will be Accept, 2. Researh and Test Reactors 7. Tranivootaton able if they provide a bash for the flndings requilte to the istuance or continuance
Standards acceptable to the NRC staff for the design and testing of normal atmosphere cleanup systems include those portions of ASME N509-1989, "Nuclear Power Plant Air-Cleaning Units and Components" (Ref. 1), ASME N510-1989, "Testing of Nuclear Air-Treatment Systems"
3. Fuels and Malrial Facilities
(Ref. 2), and ASME AG-1-1997, "Code on Nuclear Air and Gas Treatment" (Ref. 3) that are referenced in this guide and ASTM D3803-1989, "Standard Test Methods for Nuclear-Grade Activated Carbon" (Ref. 4).
8. Occupational Health of a permit or Wiants@ b the CoenmIthlon.
If a referenced standard has been incorporated separately into the NRCs regulations, licensees and applicants must comply with that standard as set forth in the regulation. If the referenced standard has been endorsed in a regulatory guide, the standard constitutes a method acceptable to the NRC staff for meeting a regulatory requirement as described in the regulatory guide. If a referenced standard has been neither incorporated into the NRCs regulations nor endorsed in a regulatory guide, licensees and applicants may consider and use the information in the referenced standard if appropriately justified, consistent with current regulatory practice.


4. Envirorinelnwtal and Sltilfg 9. Antitrust Reviyn, 5. Materiatls"d Plant Proteclion t0. General Commrents nd ugguestions for in thee guides ame encouraged it all timaes and guides will be revised, as appropriate, to accommodate commenti enfd Reouitsi for single copties of isstue guies iwhitch may :)e reuoducied or for tulace.to reflect new Informationt or eaperience.
==C. REGULATORY POSITION==
1.


Holwever, comnments On this guideif ment on an didtitiuon Ist tor ,sngie cosmse of tulqge quide in sspecific ,ohniesd within about t!wo monhst after Its Issuance.
GENERAL DESIGN AND TESTING CRITERIA
ASME AG-1-1997, Code on Nuclear Air and Gas Treatment (Ref. 3), and ASME N509-
1989, Nuclear Power Plant Air-Cleaning Units and Components (Ref. 1) provide guidance that is acceptable to the NRC staff for the performance, design, construction, acceptance testing, and quality assurance of equipment used as components in nuclear safety-related or ESF air and gas treatment systems in nuclear power plants.  Normal atmosphere cleanup systems designed to ASME N509-1989 (Ref. 1) (or its earlier versions) and tested to ASME N510-1989 (Ref. 2) (or its earlier versions) are considered adequate to protect public health and safety.


will be iParticularly useful in divisiont be madIe in writing to the US. Nuclear Regutaooiy Commission, evetuetlne the need for an teialy revition.
1.140-5
2.


Washington, D.C. 2055. Attention.
ENVIRONMENTAL DESIGN CRITERIA
2.1.


Oirector. of Oocument Cunt,ot nated as "primary systems." Primary systems gener-ally include a containment cleanup system (kidney filtration system). Systems that operate outside pri-mary containment are designated as "secondary sys-tems." Secondary systems generally include cleanup systems installed in the ventilation exhaust systems for the reactor building, turbine building, radwaste building, auxiliary building, mechanical vacuum pump, main condenser air ejector, and any other re-lease points that may contain particulates and gaseous radioiodine species. In some instances, filtration equipment installed in a postaccident hydrogen purge exhaust system may be designed to the recom-mendations of this guide, e.g., where a removal effi-ciency of 90% or less for radioiodine species is suffi-cient for the hydrogen purge exhaust system when the sum of the calculated loss-of-coolant accident (LOCA) dose and the post-LOCA
The design of each normal atmosphere cleanup system should be based on the anticipated range of operating parameters of temperature, pressure, relative humidity, and radiation levels during normal plant operations, including anticipated operational occurrences.
hydrogen purge dose is less than the guideline values of 10 CFR Part 100.Normal environmental conditions that these atmos-phere cleanup systems should withstand are inlet concentrations of radioactive iodine in the range of l0-6 to 10-13 j-Ci/cm 3 , relative humidity of the in-fluent stream up to 100%, temperatures of the in-fluent stream up to 125*F (52'C), and atmospheric pressure.


The system should be operated in such a manner that radiation levels of airborne radioactive material and redioiodine buildup on the adsorber do not deleteriously affect the operation of the filter sys-tem or any component.
2.2.


An atmosphere cleanup system installed in a nor-mal ventilation exhaust system consists of some or all of the following components:
If the normal atmosphere cleanup system is located in an area of high radiation during normal plant operation, adequate shielding of components and personnel from the radiation source should be provided.
heaters or cooling coils used in conjunction with heaters, prefilters, high-efficiency particulate air (HEPA) filters, iodine ad-sorption units, fans, and associated ductwork, dam-pers, and instrumentation.


Heaters are designed to heat the influent stream to reduce its relative humid-ity before it reaches the filters and adsorbers.
2.3.


HEPA filters are installed to remove particulate matter, which may be radioactive, and pass the air stream to the adsorber.
The operation of any normal atmosphere cleanup system should not degrade the expected operation of any ESF system that is required to operate after a design basis accident.


The adsorber removes gaseous iodine (elemental iodine and organic iodides) from the air stream. HEPA filters downstream of the adsorber units collect carbon fines and provide redundant pro-tection against particulate release in case of failure of the upstream HEPA filter bank. The fan is the final item in an atmosphere cleanup system. Consideration should be given to installing prefilters upstream of the HEPA filters to reduce the particulate load and extend their service life.The environmental history will affect the perform-ance of the atmosphere cleanup system. Industrial contaminants, pollutants, temperature, and relative humidity contribute to the aging and weathering of filters and adsorbers and reduce their capability to perform their intended functions.
2.4.


Therefore, aging, weathering, and poisoning of these components, which may vary from site to site, need to be consid-ered during design and operation.
The design of the normal atmosphere cleanup system should consider any sig- nificant contaminants such as dusts, chemicals, excessive moisture, or other particulate matter that could degrade the cleanup system's operation.


Average temper-ature and relative humidity also vary from site to site, and the potential buildup of moisture in the adsorber warrants equal design consideration.
3.


The effects of these factors on the atmosphere cleanup system can be determined by scheduled testing during operation.
SYSTEM DESIGN CRITERIA
Normal atmosphere cleanup systems should be designed in accordance with Section 4.0 of ASME N509-1989 (Ref. 1) and ASME AG-1-1997 (Ref. 3) as modified and supplemented by the following:
3.1.


All components of the atmosphere cleanup system installed in normal ventilation exhaust systems need to be designed for reliable performance under the ex-pected operating conditions.
Normal atmosphere cleanup systems need not be redundant nor designed to Seismic Category I classification, but they should consist of at least the following components:  (1) HEPA
filters before the adsorbers, (2) iodine adsorbers (impregnated activated carbon), (3) fans, and (4)
interspersed ducts, dampers, and related instrumentation.  To reduce the particulate load on the HEPA filters and extend their service life, the installation of prefilters upstream from the initial HEPA section is suggested.  Consideration should also be given to the installation of a HEPA filter or medium efficiency postfilter (as defined in Section 5.3 of ASME N509-1989 (Ref. 1))
downstream from carbon adsorbers to retain carbon fines.  Heaters or cooling coils or both may be used when the humidity is to be controlled before filtration.  Whenever a normal atmosphere cleanup system is designed to remove only particulate matter, a component for iodine adsorption need not be included.


Initial testing and proper maintenance are primary factors in ensuring the relia-bility of the system. Careful attention during the de-sign phase to problems of system maintenance can contribute significantly to the reliability of the system by increasing the ease of such maintenance.
3.2.


Of par-ticular importance in the design is a layout that pro-vides accessibility and sufficient working space so that the required functions can be performed safely.Periodic testing during operation to verify the effi-ciency of the components is another important means of ensuring reliability.
To ensure reliable in-place testing, the volumetric air-flow rate of a single cleanup unit should be limited to approximately 30,000 cubic feet per minute. If a total system air flow in excess of this rate is required, multiple units should be used.


Built-in features that will facilitate convenient in-place testing are important in system design.Standards for the design and testing of atmosphere cleanup systems include ANSI /ASME N509-1976,"Nuclear Power Plant Air Cleaning Units and Com-ponents" (Ref. 1), and ANSI N510-1975, "Testing of Nuclear Air Cleaning Systems" (Ref. 2).Other standards are available for the construction and testing of certain components of systems. Where such standards are acceptable to the NRC staff, they are referenced in this guide. Where no suitable stand-ard exists, acceptable approaches are presented in this guide. ERDA 76-21, "Nuclear Air Cleaning Handbook" (Ref. 3), provides a comprehensive re-view of air filtration systems. It is not ! standard but a guide that discusses a number of acceptable design alternatives.
3.3.


Not all of the documents mentioned in ANSI N509-1976 (Ref. 1), ANSI N510-1975 (Ref. 2), or other standards referenced in this guide have been the subject of an evaluation by the NRC staff as to their applicability or acceptability.
Each normal atmosphere cleanup system should be instrumented to monitor and alarm pertinent pressure drops and flow rates in accordance with the recommendations of Section
5.6 of ERDA 76-21 (Ref. 5) and Section 4.9 of ASME N509-1989 (Ref. 1).  


It should be noted that ANSI N509-1976 and ANSI N510-1975 refer to ORNL-NSIC-65, "Design, Construction and Testing of High-Efficiency Air Filtration Systems for Nuclear Application" (Ref. 4), which has been replaced by ERDA 76-21 (Ref. 3).C. REGULATORY
1.140-6
POSITION Section 2 of ANSI N509-1976 (Ref. 1) and Sec-tion 2 of ANSI N510-1975 (Ref. 2) list additional documents referred to in these standards.
3.4.


The specific applicability or acceptability of these listed docu-ments, as well as documents listed in other standards referenced in this guide, has been or will be covered separately in other regulatory guides, where appro-priate.Where reference is made to ORNL-NSIC-65 (Ref.4) in ANSI N509-1976 and in ANSI N510-1975, it*~1.140-2 should be interpreted to mean the corresponding por-tion of ERDA 76-21 (Ref. 3).1. Environmental Design Criteria a. The design of each atmosphere cleanup sys-tem installed in a normal ventilation exhaust system should be based on the maximum anticipated operat-ing parameters of temperature, pressure, relative humidity, and radiation levels. The cleanup system should be designed based on continuous operation for the expected life of the plant or the maximum antici-pated service life of the cleanup system.b. If the atmosphere cleanup system is located in an area of high radiation during normal plant opera-tion, adequate shielding of components from the radiation source should be provided.c. The operation of any atmosphere cleanup sys-tem in a normal ventilation exhaust system should not deleteriously affect the expected operation of any engineered-safety-feature system that must operate after a design basis accident.d. The design of the atmosphere cleanup system should consider any significant contaminants such as dusts, chemicals, or other particulate matter that could deleteriously affect the cleanup system's opera-tion.2. System Design Criteria a. Atmosphere cleanup systems installed in normal ventilation exhaust systems need not be re-dundant nor designed to seismic Category I classifica- tion, but should consist of the following sequential components:
To maintain the radiation exposure to operating and maintenance personnel as low as is reasonably achievable (ALARA), normal atmosphere cleanup systems and components should be designed to control leakage and facilitate maintenance, inspection, and testing in accordance with the guidance in Regulatory Guide 8.8, "Information Relevant to Ensuring that Occupational Radiation Exposures at Nuclear Power Stations Will Be As Low As Is Reasonable Achievable" (Ref. 6).  
(1) HEPA filters before the adsorbers, (2) iodine adsorbers (impregnated activated carbon or equivalent adsorbent such as metal zeolites), (3)ducts and dampers, (4) fans, and (5) related in-strumentation.
3.5.


If it is desired to reduce the particulate load on the HEPA filters and extend their service life, the installation of prefilters upstream of the initial HEPA bank is suggested.
Outdoor air intake openings should be equipped with louvers, grills, screens, or similar protective devices to minimize the effects of high winds, rain, snow, ice, trash, and other contaminants on the operation of the system.  The outdoor air intake openings should be located to minimize the effects of possible onsite plant contaminants, such as the diesel generator exhaust.  If the atmosphere surrounding the plant could contain significant environmental contaminants, such as dusts and residues from smoke-cleanup systems from adjacent coal-burning power plants or industry, or is a salty environment near an ocean, the design of the system should consider these contaminants and prevent them from affecting the operation of any normal atmosphere cleanup system.


Consideration should also be given to the installation of a HEPA filter bank downstream of carbon adsorbers to retain carbon fines. Heaters or cooling coils used in conjunction with heaters should be used when the humidity is to be controlled before filtration.
3.6.


b. The volumetric air flow rate of a single cleanup train should be limited to approximately
Normal atmosphere cleanup system housings and ductwork should be designed to exhibit, on test, a maximum total leakage rate as defined in Article SA-4500 of ASME AG-1-1997 (Ref. 3).  Duct and housing leak tests should be performed in accordance with Section TA of ASME AG-1-1997.
30,000 ft 3/min. If a total system air flow in excess of this rate is required, multiple trains should be used. For ease of maintenance, a filter layout that is three HEPA filters high and ten wide is preferred.


c. Each atmosphere cleanup system should be locally instrumented to monitor and alarm pertinent pressure drops and flow rates in accordance with the recommendations of Section 5.6 of ERDA 76-21 (Ref. 3).d. To maintain the radiation exposure to operat-ing personnel as low as is reasonably achievable dur-ing plant maintenance, atmosphere cleanup systems should be designed to control leakage and facilitate maintenance in accordance with the guidelines of Regulatory Guide 8.8, "Information Relevant to En-suring that Occupational Radiation Exposures at Nu-clear Power Stations Will Be As Low As Is Rea-sonably Achievable" (Ref. 5).e. Outdoor air intake openings should be equipped with louvers, grills, screens, or similar pro-tective devices to minimize the effects of high winds, rain, snow, ice, trash, and other contaminants on the operation of the system. If the atmosphere surround-ing the plant could contain significant environmental contaminants, such as dusts and residues from smoke cleanup systems from adjacent coal burning power plants or industry, the design of the system should consider these contaminants and prevent them from affecting the operation of any atmosphere cleanup system.f. Atmosphere cleanup system housings and ductwork should be designed to exhibit on test a maximum total leakage rate as defined in Section 4.12 of ANSI N509-1976 (Ref. 1). Duct and housing leak tests should be performed in accordance with the provisions of Section 6 of ANSI N510-1975 (Ref. 2).3. Component Design Criteria and Qualification Testing a. Adsorption units functon efficiently at a rela-tive humidity of 70% or less. If the relative humidity of the incoming atmosphere is expected to be greater than 70% during normal reactor operation, heaters or cooling coils used in conjunction with heaters should be designed to reduce the relative humidity of the in-coming atmosphere to 70%. Heaters should be de-signed, constructed, and tested in accordance with the requirements of Section 5.5 of ANSI N509-1976 (Ref. 1) exclusive of sizing criteria.b. The HEPA filters should be designed, con-structed, and tested in accordance with the require-ments of Section 5.1 of ANSI N509-1976 (Ref. 1).Each HEPA filter should be tested for penetration of dioctyl phthalate (DOP) in accordance with the provi-sions of MIL,-F-51068 (Ref. 6) and MIL.-STD-282 (Ref. 7).e. Filter and adsorber mounting frames should be designed and constructed in accordance with the provisions of Section 5.6.3 of ANSI N509-1976 (Ref. 1).d. Filter and adsorber banks should be arranged in accordance with the recommendations of Section 4.4 of ERDA 76-21 (Ref. 3).e. System filter housings, including floors and doors, and electrical conduits, drains, and piping in-stalled inside filter housings should be designed and constructed in accordance with the provisions of Sec-tion 5.6 of ANSI N509-1976 (Ref. 1).f. Ductwork associated with the atmosphere cleanup system should be designed, constructed, and 1,140-3-_MMM&#xfd;
4.
I tested in accordance with the provisions of Section 5.10 of ANSI N509-1976 (Ref. 1).g. The adsorber section of the atmosphere cleanup system may contain any adsorbent material demonstrated to remove gaseous iodine (elemental iodine and organic iodides) from air at the required efficiency.


Since impregnated activated carbon is commonly used, only this adsorbent is discussed in this guide. Each original or replacement batch of im-pregnated activated carbon used in the adsorber sec-tion should meet the qualification and batch test re-sults summarized in Table I of this guide.* If an adsorbent other than impregnated activated carbon is proposed or if the mesh size distribution is different from the specifications in Table 1, the pro-posed adsorbent should have demonstrated the capa-* bility to perform as well L- or better than activated carbon in satisfying the specifications in Table I. If impregnated activated carbon is used as the adsor-bent, the adsorber system should be designed for an average atmosphere residence time of 0.25 sec per two inches of adsorbent bed.h. Adsorber cells should be designed, con-structed, and tested in accordance with the require-ments of Section 5.2 of ANSI N509-1976 (Ref. 1).i. The system fan and motors, mounting, and ductwork connections should be designed, con-structed, and tested in accordance with the require-ments of Sections 5.7 and 5.8 of ANSI N509-1976 (Ref. I).j. The fan or blower used in the atmosphere cleanup system should be capable of operating under the environmental conditions postulated.
COMPONENT DESIGN CRITERIA AND QUALIFICATION TESTING
Components of normal atmosphere cleanup systems should be designed, constructed, and tested in accordance with Division II of ASME AG-1-1997 (Ref. 3), as modified and supplemented by the following.


k. Ducts and housings should be laid out with a minimum of ledges, protrusions, and crevices that could collect dust and moisture and that could impede personnel or create a hazard to them in the perform-ance of their work. Straightening vanes should be in-stalled where required to ensure representative air flow measurement and uniform flow distribution through cleanup components., 1. Dampers should be designed, constructed, and tested in accordance with the provisions of Section 5.9 of ANSI N509-1976 (Ref. 1).4. Maintenance a. Accessibility of components and maintenance should be considered in the design of atmosphere cleanup systems in accordance with the provisions of Section 2.3.8 of ERDA 76-21 (Ref. 3) and Section 4.7 of ANSI N509-1976 (Ref. 1).b. For ease of maintenance, the system design should provide for a minimum of three feet from..mounting frame to mounting frame between banks of components.
4.1.


If components are to be replaced, the dimensions to be provided should be the maximum length of the component plus a minimum of three feet.c. The system design should provide for perma-nent test probes with external connections in accord-ance with the provisions of Section 4.11 of ANSI N509-1976 (Ref. 1).d. The cleanup components (e.p., HEPA filters and adsorbers)
Prefilters that are used in the normal atmosphere cleanup system should be designed, constructed, and tested in accordance with Section FB of ASME AG-1-1997.
should be installed after construction is completed.


5. In-Place Testing Criteria a. A visual inspection of the atmosphere cleanup system and all associated components should be made before each in-place airflow distribution test, DOP test, or activated carbon adsorber section leak test in accordance with the provisions of Section 5 of ANSI N510-1975 (Ref. 2).b. The airflow distribution to the HEPA filters and iodine adsorbers should be tested inplace for uniformity initially and after maintenance affecting the flow distribution.
4.2.


The distribution should be within +/- 20% of the average flow per unit when tested in accordance with the provisions of Section 9 of "Industrial Ventilation" (Ref. 8) and Section 8 of ANSI N510-1975 (Ref. 2).c. The in-place DOP test for HEPA filters should conform to Section 10 of ANSI N510-1975 (Ref. 2).HEPA filter sections should be tested in place ini-tially and at a frequency not to exceed 18 months thereafter (during a scheduled reactor shutdown is ac-ceptable).
Air heaters should be designed, constructed, and tested in accordance with Section CA of ASME AG-1-1997.
The HEPA filter bank upstream of the ad-sorber section should also be tested following paint-ing, fire, or chemical release in any ventilation zone communicating with the system in such a manner that the HEPA filters could become contaminated from the fumes, chemicals, or foreign materials.


DOP penetration tests of all HEPA filter banks should con-firm a penetration of less than 0.05% at rated flow. A filtration system satisfying this condition can be con-sidered to warrant a 99% removal efficiency for par-ticulates.
4.3.


HEPA filters that fail to satisfy the in-place test criteria should be replaced with filters qualified pursuant to regulatory position C.3.b of this guide. If the HEPA filter bank is entirely or only partially re-placed, an in-place DOP test should be conducted.
The HEPA filters should be designed, constructed, and tested in accordance with Section FC of ASME AG-1-1997. Each HEPA filter should be tested for penetration of a challenge aerosol such as dioctyl phthalate (DOP) in accordance with Section TA of ASME AG-1-
1997.


If any welding repairs are necessary on, within, or adjacent to the ducts, housing, or mounting frames, the filters and adsorbers should be removed from the housing during such repairs. These repairs should be completed prior to periodic testing, filter inspection, and in-place testing. The use of silicone sealants or any other temporary patching material on filters, housing, mounting frames, or ducts should not be allowed.d. The activated carbon adsorber section should be leak-tested with a gaseous halogenated hydrocarbon refrigerant in accordance with Section 12 of ANSI N510-1975 (Ref. 2) to ensure that bypass leakage through the adsorber section is less than 0.05%. After the test is completed, air flow through the unit should be maintained until the residual refrigerant gas in the effluent is less than 0.01 ppm. Adsorber leak testing 1.140-4 should be conducted
4.4.
(1) initially, (2) at a frequency not to exceed 18 months thereafter (during a sched-uled reactor shutdown is acceptable), (3) following removal of an adsorber sample for laboratory testing if the integrity of the adsorber section is affected, and (4) following painting, fire, or chemical release in any ventilation zone communicating with the system in such a manner that the charcoal adsorbers could become contaminated from the funs, chemicals, or foreign materials.


6. Laboratory Testing Criteria for Activated Carbon a. The activated carbon adsorber section of the atmosphere cleanup system should be assigned the decontamination efficiencies given in Table 2 for radioiodine if the following conditions are met: (1) The adsorber section meets the conditions given in regulatory position C.5.d of this gvi'i_., (2) New activated carbon meets the physical property specifications given in Table 1, and (3) Representative samples of used activated carbon pass the laboratory tests given in Table 2.If the activated carbon fails to meet any of the above conditions, it should not be used in adsorption units.b. The efficiency of the activated carbon ad-sorber section should be determined by laboratory testing of representative samples of the activated car-bon exposed simultaneously to the same service con-ditions as the adsorber section. Each representative sample should be not less than two inches in both length and diameter, and each sample should have the same qualification and batch test characteristics as the system adsorbent.
The HEPA filter and Type II adsorber cell mounting frames should be designed and constructed in accordance with Section FG of ASME AG-1-1997.


There should be a sufficient number of representative samples located in parallel with the adsorber section to estimate the amount of penetration of the system adsorbent throughout its service life. The design of the samplers should be in accordance with the provisions of Appendix A of ANSI N509-1976 (Ref. 1). Where the system acti-vated carbon is greater than two inches deep, each representative sampling station should consist of enough two-inch samples in series to equal thc thick-ness of the system adsorbent.
4.5.


Once reprcsentative samples are removed for laboratory test their posi-tions in the sampling array should be blocked off.Laboratory tests of representative samples should be conducted, as indicated in Table 2 of this guide, with the test gas flow in the same direction as the flow during service conditions.
Filter and adsorber sections should be arranged in accordance with Section 4.4 of ERDA 76-21 (Ref. 5) and Section HA, Housings, of ASME AG-1a-2000 (Ref. 7).  


Similar laboratory tests should be performed on an adsorbent sample be-fore loading into the adsorbers to establish an initial point for comparison of future test results. The acti-vated carbon adsorber section should be replaced with new unused activated carbon meeting the physi-cal property specifications of Table I if (1) testing in accordance with the frequency specified in Footnote c of Table 2 results in a representative sample failing to pass the applicable test in Table 2 or (2) no represen-tative sample is available for testing.
1 Activated carbon is typically impregnated with a chemical compound or compounds to enhance radioiodine retention, particularly under conditions of high temperatures and humidity.  Typical impregnants include iodides such as potassium iodide and triiodide, amines such as triethylenediamine (TEDA), and combinations thereof.
 
1.140-7
4.6.
 
System filter housings, including floors and doors, and electrical conduits, drains, and piping installed inside filter housings should be designed and constructed in accordance with Section 5.6 of ASME N509-1989 (Ref. 1) and Section HA, ASME AG-1a-2000 (Ref. 7).
4.7.
 
Adsorption units function efficiently at a relative humidity of 70% or less.  If the relative humidity of the atmosphere entering the air cleanup system is expected to be greater than
70% during normal reactor operation, heaters or cooling coils should be designed to reduce the relative humidity of the atmosphere entering the adsorption unit to 70% or less.  Heaters should be designed, constructed, and tested in accordance with Section CA of ASME AG-1-1997 (Ref. 3)
exclusive of sizing criteria.
 
4.8.
 
Adsorber cells should be designed, constructed, and tested in accordance with Section FD for Type II Adsorber cells or Section FE for Type III Adsorber cells of ASME AG-1-
1997.
 
The design of the adsorber section should consider possible iodine desorption and adsorbent auto-ignition that may result from radioactivity-induced heat in the adsorbent and concomitant temperature rise.  Acceptable designs include a low-flow air bleed system, cooling coils, water sprays for the adsorber section, or other cooling mechanisms.
 
When a water-based fire suppression or prevention (cooling) system is installed in the normal atmosphere cleanup system housing, the fire system should be manually actuated unless there is a reasonable probability that the iodine desorption and adsorbent auto-ignition could occur in the housing, in which case the fire system should have both automatic and manual actuation.
 
The fire system should use open spray nozzles or devices of sufficient size, number, and location to provide complete coverage over the entire surface of the combustible filter media.  The fire system should be hard piped and supplied with a reliable source of water at adequate pressure and volume.  The location of the manual release (or valve) for the fire system should be remote from the cleanup system housing and should be consistent with the ALARA guidance in Regulatory Guide 8.8 (Ref. 6).  Automatic fire systems should include a reliable means of detection to actuate the system.  Detection can be accomplished by a mechanical or electrical device including, but not limited to, thermal, carbon monoxide, or smoke.  Cross-zoning of detectors is acceptable.  Manual fire systems should include a reliable means of internal monitoring for determining when to manually actuate the fire systems.  The monitoring indication should be remote from the cleanup system housing in accordance with ALARA practices.
 
4.9.
 
The adsorber section of the normal atmosphere cleanup system may contain any adsorbent material demonstrated to remove gaseous iodine (elemental iodine and organic iodides)
from air at the required efficiency.  However, since impregnated activated carbon1 is used almost exclusively, only impregnated activated carbon is discussed in this guide.
 
2  A batch of activated carbon or a batch of impregnated activated carbon is a quantity of adsorbent, not to exceed 10 cubic meters (or 350 cubic feet), of the same grade or type that has been produced under the same manufacturers production designation using a consistent manufacturing procedure and equipment, and that has been homogenized to exhibit the same physical properties and performance characteristics throughout the mass.  (See Article FF-1130 of ASME AG-1-1997).
3  A "lot of activated carbon" or a "lot of impregnated activated carbon" is a quantity of adsorbent consisting of one or more batches of adsorbent that constitute and satisfy a purchase order.  (See Article FF-1130 of ASME AG-1-1997).
1.140-8 Each original or replacement batch or lot of impregnated activated carbon used in the adsorber section should meet Section FF of ASME AG-1-1997 (Ref. 3).2,3  A test performed as a
"qualification test" should be interpreted to mean a test that establishes the suitability of a manufacturer's product for a generic application, normally a one-time test establishing typical performance of the product.  Tests not specifically identified as being performed only for qualification purposes should be interpreted as "batch tests."  Batch tests are tests to be made on each production batch of product to establish suitability for a specific application.
 
If impregnated activated carbon is used as the adsorbent, the adsorber system should be designed for an average atmosphere residence time of 0.25 seconds per two inches of adsorbent bed.  Sections FD and FE of ASME AG-1-1997 should be used to determine the residence time.
 
If an adsorbent other than impregnated activated carbon is proposed or if the mesh size distribution or other physical properties of the impregnated activated carbon are different from the specifications above, the proposed adsorbent should have the capability to perform as well as or better than activated carbon that satisfies the specifications in Article FF of ASME AG-1-1997.
 
If sample canisters are used, they should be designed in accordance with Appendix A to ASME N509-1989 (Ref. 1).
4.10.
 
Ductwork associated with the normal atmosphere cleanup system should be de- signed, constructed, and tested in accordance with Section SA of ASME AG-1-1997.
 
4.11.
 
Ducts and housings should be laid out with a minimum of ledges, protrusions, and crevices that could collect dust and moisture and that could impede personnel or create a hazard to them in the performance of their work.  Turning vanes or other air flow distribution devices should be installed where required to ensure representative air flow measurement and uniform flow distri- bution through cleanup components.
 
4.12.
 
Dampers should be designed, constructed, and tested in accordance with Section DA of ASME AG-1-1997.
 
4.13.
 
The system fan and motor, mounting, and ductwork connections should be designed, constructed, and tested in accordance with ASME AG-1-1997 in Section BA for Blowers and Section SA for Ducts.  The fan and motor used in the normal atmosphere cleanup system should be capable of operating under the environmental conditions postulated for its use.
 
4  In 1998, the Department of Energy (DOE) presented the results of its HEPA filter deterioration research at the 25th DOE/NRC
Nuclear Air Cleaning and Treatment Conference (Ref. 8).  The results of this research demonstrated that wetting of the filter medium significantly reduces its tensile strength, which is not fully recovered after drying.  In addition, further water exposures resulted in additional losses in filter media tensile strength.  (See NRC Information Notice 99-01, Ref. 9).
5 Painting, fire, or chemical release is not communicating with the HEPA filter or adsorber if the ESF atmosphere cleanup system is not in operation, the isolation dampers for the system are closed, and there is no pressure differential across the filter housing.  This provides reasonable assurance that air is not passing through the filters and adsorbers.  A program should be developed and consistently applied that defines the terms painting, fire, and chemical release in terms of the potential for degrading the HEPA filters and adsorbers.  This program should be based on a well-documented, sound and conservative technical basis (i.e., the criteria should overestimate the potential damage to the filter and adsorber).
1.140-9
5.
 
MAINTAINABILITY CRITERIA
Provisions for maintaining normal atmosphere cleanup systems should be incorporated in the system design in accordance with Section 4.8 of ASME N509-1989 (Ref. 1) and Section HA of ASME AG-1a-2000 (Ref. 7) as supplemented by the following.
 
5.1.
 
Accessibility of components and maintenance should be considered in the design of normal atmosphere cleanup systems in accordance with Section 2.3.8 of ERDA 76-21 (Ref. 5) and Section HA of ASME AG-1a-2000 (Ref. 7).  For ease of inspection and maintenance, the system design should provide for a minimum of 3 feet from mounting frame to mounting frame between banks of components.  If components are to be replaced, the dimensions to be provided should be the maximum length of the component plus a minimum of 3 feet.
 
5.2.
 
The cleanup components (i.e., HEPA filters, prefilters, and adsorbers) that are used during construction of the ventilation systems should be replaced before the system is declared operable.
 
6.
 
IN-PLACE TESTING CRITERIA
Initial in-place testing of normal atmosphere cleanup systems should be performed in accordance with Section TA of ASME AG-1-1997 (Ref. 3).  Periodic, in-place testing of normal atmosphere cleanup systems and components should be performed in accordance with ASME
N510-1989 (Ref. 2) as modified and supplemented by the following:
6.1.
 
A visual inspection of the normal atmosphere cleanup system and all associated components should be performed in accordance with Section 5 of ASME N510-1989.
 
6.2.
 
In-place aerosol leak tests for HEPA filters upstream from the carbon adsorbers in normal atmosphere cleanup systems should be performed (1) initially, (2) at least once each 24 months, (3) after each partial or complete replacement of a HEPA filter bank, (4) following detection of, or evidence of, penetration or intrusion of water or other material into any portion of a normal atmosphere cleanup system that may have an adverse effect on the functional capability of the filters,4 and (5) following painting, fire, or chemical release in any ventilation zone communicating with the system that may have an adverse effect on the functional capability of the system.5  The test should be performed in accordance with Section 10 of ASME N510-1989 (Ref.
 
6  In Section FD-1130 of ASME AG-1-1997 (Ref. 3), penetration is defined as the exit concentration of a given gas from an air cleaning device, expressed as a percentage of inlet concentration.  In Section 3 of ASME N509-1989 (Ref. 1), bypass is defined as a pathway through which contaminated air can escape treatment by the installed HEPA or adsorber banks.  Examples are leaks in filters and filter mounting frames, defective or inefficient isolation dampers that result in uncontrolled flow through adjacent plenums, and unsealed penetrations for electrical conduits, pipes, floor drains, etc.
 
7  Care should be taken to ensure that the aerosol generator is compatible with the selected alternative challenge agent (see NRC
Information Notice 99-34, Ref. 10).
1.140-10
2).  The leak test should confirm a combined penetration and leakage (or bypass)6 of the normal atmosphere cleanup system of less than 0.05% of the challenge aerosol at rated flow +/-10%.  A
filtration system satisfying this condition can be considered to warrant a 99% removal efficiency for particulates.
 
HEPA filter sections in normal atmosphere cleanup systems that fail to satisfy the appropriate leak-test conditions should be examined to determine the location and cause of leaks.
 
Repairs, such as alignment of filter frames and tightening of filter hold-down bolts, may be made;
however, repair of defective, damaged, or torn filter media by patching or using caulking materials is not recommended in normal atmosphere cleanup systems, and such filters should be replaced and not repaired.  HEPA filters that fail to satisfy test conditions should be replaced with filters qualified pursuant to Regulatory Position 4.3 of this guide.  After repairs or filter replacement, the normal atmosphere cleanup system should be retested as described above in this Regulatory Position.
 
In accordance with ASME N510-1989 (Ref. 2) and Article TA-1000 of ASME AG-1-1997 (Ref. 3), the standard challenge aerosol used in the in-place leak testing of HEPA filters is polydisperse droplets of dioctyl phthalate (DOP), also known as di-2-ethylhexyl-phthalate (DEHP).
The 0.3 micrometer monodisperse DOP aerosol is used for efficiency testing of individual HEPA
filters by manufacturers.  Alternative challenge agents7 may be used to perform in-place leak testing of HEPA filters when their selection is based on the following.
 
1. The challenge aerosol has the approximate light scattering droplet size specified in Article TA-1130 of ASME AG-1-1997
2. The challenge aerosol has the same in-place leak test results as DOP.
 
3. The challenge aerosol has similar lower detection limit, sensitivity, and precision as DOP.
 
4. The challenge aerosol causes no degradation of the HEPA filter or the other normal air cleaning system components under test conditions.
 
5. The challenge aerosol is listed in the Environmental Protection Agency's Toxic Substance Control Act (TSCA) (Ref. 11) inventory for commercial use.
 
6.3.
 
In-place leak testing for adsorbers should be performed (1) initially, (2) at least once each 24 months, (3) following removal of an adsorber sample for laboratory testing if the integrity of the adsorber section is affected, (4) after each partial or complete replacement of carbon adsorber in an adsorber section, (5) following detection of, or evidence of, penetration or intrusion of water or other material into any portion of a normal atmosphere cleanup system that may have an adverse effect on the functional capability of the adsorbers, and (6) following painting, fire, or
 
1.140-11 chemical release in any ventilation zone communicating with the system that may have an adverse effect on the functional capability of the system.5  The test should be performed in accordance with Section 11 of ASME N510-1989 (Ref. 2).  The leak test should confirm a combined penetration and leakage (or bypass)6 of the adsorber section of 0.05% or less of the challenge gas at rated flow+/-10%.
Adsorber sections that fail to satisfy the appropriate leak-test conditions should be examined to determine the location and cause of leaks.  Repairs, such as alignment of adsorber cells, tightening of adsorber cell hold-down bolts, or tightening of test canister fixtures, may be made; however, the use of temporary patching material on adsorbers, filters, housings, mounting frames, or ducts should not be allowed.  After repairs or adjustments have been made, the adsorber sections should be retested as described above in this Regulatory Position.
 
In accordance with ASME N510-1989 (Ref. 2) and Section TA of ASME AG-1-1997 (Ref.
 
3), the standard challenge gas used in the in-place leak testing of adsorbers is Refrigerant-11 (trichloromonofluoromethane).  Alternative challenge gases may be used to perform in-place leak testing of adsorbers when their selection is based on meeting the characteristics specified in Appendix TA-C of ASME AG-1-1997.
 
6.4.
 
If any welding repairs are necessary on, within, or adjacent to the ducts, housing, or mounting frames, the HEPA filters and adsorbers should be removed from the housing (or otherwise protected) prior to performing such repairs.  The repairs should be completed prior to re- installation of filters and adsorbers; the system should then be visually inspected and leak tested as in Regulatory Positions 6.2, 6.3, and 6.4.
 
7.
 
LABORATORY TESTING CRITERIA FOR ACTIVATED CARBON
7.1.
 
The activated carbon adsorber section of the normal atmosphere cleanup system should be assigned the decontamination efficiencies given in Table 1 for radioiodine if the following conditions are met:
1.
 
The adsorber section meets the conditions given in Regulatory Position 6.3 of this guide,
2.
 
New activated carbon meets the physical property specifications given in Regulatory Position 4.9 of this guide, and
3.
 
Representative samples of used activated carbon pass the laboratory tests given in Table 1 of this guide.
 
If the activated carbon fails to meet any of the above conditions, it should not be used in adsorption units.
 
7.2.
 
The efficiency of the activated carbon adsorber section should be determined by laboratory testing of representative samples of the activated carbon exposed simultaneously to the same service conditions as the adsorber section.  Each representative sample should be not less
 
1.140-12 than 2 inches in both length and diameter, and each sample should have the same qualification and batch test characteristics as the system adsorbent.  There should be a sufficient number of representative samples located in parallel with the adsorber section to estimate the amount of penetration of the system adsorbent throughout its service life.  The design of the samples should be in accordance with Appendix A to ASME N509-1989 (Ref. 1).  Where system activated carbon is greater than 2 inches deep, each representative sampling station should consist of enough 2-inch samples in series to equal the thickness of the system adsorbent.  Once representative samples are removed for laboratory testing, their positions in the sampling array should be blocked off.
 
Sampling and analysis should be performed (1) initially, (2) at intervals of approximately
24 months, (3) following painting, fire, or chemical release in any ventilation zone communicating with the system that may have an adverse effect on the functional capability of the carbon media,5 and (4) following detection of, or evidence of, penetration of water or other material into any portion of the filter system that may have an adverse effect on the functional capability of the carbon media.
 
Laboratory tests of representative samples should be conducted, as indicated in Table 1 of this guide, with the test gas flow in the same direction as the flow during service conditions.
 
Similar laboratory tests should be performed on an adsorbent sample before loading into the adsorbers to establish an initial point for comparison of future test results. The activated carbon adsorber section should be replaced with new unused activated carbon meeting the physical property specifications given in Regulatory Position 4.9 of this guide if (1) testing in accordance with Table 1 results in a representative sample that fails to pass the acceptance criterion or (2) no representative sample is available for testing.


==D. IMPLEMENTATION==
==D. IMPLEMENTATION==
The purpose of this section is to provide informa-tion to applicants and licensees regarding the NRC staff's plans for using this regulatory guide.This guide reflects current NRC staff practice.Therefore, except in those cases in which the appli-cant or licensee proposes an acceptable alternative method for complying with specified portions of the Commission's regulations, the method described herein is being and will continue to be used in the evaluation of submittals for operating license or con-struction permit applications until this guide is re-vised as a result of suggestions from the public or additional staff review.I 1.140-5 I,  
The purpose of this section is to provide information to applicants and licensees regarding the NRC staff's plans for using this regulatory guide.
TABLE 1 PHYSICAL PROPERTIES
 
OF NEW ACTIVATED
Except in those cases in which an applicant or licensee proposes an acceptable alternative method for complying with specified portions of the NRC's regulations, the methods described in this guide, which reflect public comments, will be used by the NRC staff in its evaluation of submittals in connection with the design, inspection, and testing of normal atmosphere cleanup systems for the following light-water-cooled nuclear power plants:
CARBON BATCH TESTS" TO BE PERFORMED
1.
ON FINISHED ADSORBENT Test 1. Particle size distribution
 
2. Hardness number 3. Ignition te-aperature
Plants for which the construction permit or license application is docketed after the issue date of this guide;
4. CCI 4 Activity'5. Radioiodine removal efficiency a. Elemental iodine, 25&deg;C and 95% relative humidity b. Methyl iodide, 25*C and 95% relative humidity 6. Bulk density 7. Impregnant content Acceptable Test Method ASTM D2862 (Ref. 9)RDT M16-IT, Appendix C (Ref. 10)RDT M16-IT, Appendix C (Ref. 10)CCI 4 Activity, RDT M16-IT, Appendix C (Ref. 10)RDT M 16-IT (Ref. 10)para. 4.5.1, except 95% relative humidity air is required RDT MI6-IT (Ref. 10)para. 4.5.3, except 95% relative humidity air is required ASTM D2854 (Ref. 11)State procedure Acceptable Results Retained on #6 ASTM El 1 b Sieve: 0.0%Retained on #8 ASTM El ! Sieve: 5.0% max.Through #8, rctained on #12 Sieve: 40% to 60%Through # 12, retained on # 16 Sieve: 40% to 60%Through # 16 ASTM Elib Sieve: 5.0% max.Through #18 ASTM ElIb Sieve: 1.0% max.95 minimum 330"C minimum at 100 fpm 60 minimum 99.5%95%0.38 g/ml minimum State type (not to exceed 5% by weight)a A "batch test" is a test made on a production batch of a product to establish suitability for a specific application.
2.
 
Plants for which the licensee voluntarily commits to the provisions of this guide.
 
1.140-13 Table 1: Laboratory Tests For Activated Carbon Activated Carbona Total Bed Depthb Maximum Assigned Activated Carbon Decontamination Efficiencies Methyl Iodide Penetration Acceptance Criterion for Representative Sample
2 inches Elemental iodine Organic iodide
95%
95%
Penetration 5% when tested in accordance with ASTM D-3803-
1989 (Ref. 4)
4 inches or greater Elemental iodine Organic iodide
99%
99%
Penetration 1% when tested in accordance with ASTM D-3803-
1989 (Ref. 4)
a The activated carbon, when new, should meet the specifications of Regulatory Position 4.9 of this guide.
 
b  Multiple beds, e.g., two 2-inch beds in series, should be treated as a single bed of aggregate depth.  It is advantageous when series beds are located in separate housings and individually in-place leak tested.  This aids in mixing the challenge agent and contributes to the accuracy of the test results.
 
NOTES:
(1)  Credited decontamination efficiencies (a portion of which includes bypass leakage) are based on 0.25 second residence time per 2-inch bed depth.
 
(2)  Organic iodide and elemental iodine are the forms of iodine that are expected to be absorbed by activated carbon.
 
Organic iodide is more difficult for activated carbon to adsorb than elemental iodine.  Therefore, the laboratory test to determine the performance of the activated carbon adsorber is based on organic iodide.  Methyl iodide is the organic form of iodine that is used in the laboratory test.
 
(3)  This Table 1 provides acceptable decontamination efficiencies and methyl iodide test penetrations of used activated carbon samples for laboratory testing. Laboratory tests are conducted in accordance with ASTM D3803-
1989 (Ref. 4). Tests are conducted at a temperature of 30&deg;C and relative humidity of 95%, except a relative humidity of 70% is used when the air entering the carbon adsorber is maintained at less than or equal to 70% relative humidity.
 
(4)  See Appendix A to ASME N509-1989 (Ref. 1) for the definition of a representative sample.  Testing should be performed at the frequencies specified in Regulatory Position 7.2 of this guide.  Testing should be performed in accordance with ASTM D3803-1989 (Ref. 4) at a temperature of 30&deg;C and a relative humidity of 95% (or 70% with humidity control).  Humidity control can be provided by heaters or an analysis that demonstrates that the air entering the carbon will be maintained less than or equal to 70% relative humidity.
 
1 Copies may be purchased from the National Technical Information Service by writing NTIS, 5285 Port Royal Road, Springfield, VA 22161; telephone (703)487-4650; online <http://www.ntis.gov/ordernow>. 
2  Single copies of regulatory guides, both active and draft, may be obtained free of charge by writing the Reproduction and Distribution Services Section, OCIO, USNRC, Washington, DC 20555-0001, or by fax to (301)415-2289, or by email to
<DISTRIBUTION@NRC.GOV>.  Active guides may also be purchased from the National Technical Information Service on a standing order basis. Details on this service may be obtained by writing NTIS, 5285 Port Royal Road, Springfield, VA 22161;
telephone (800)553-6847; online <http://www.ntis.gov/ordernow>.  Copies of certain guides and many other NRC documents are available electronically on the internet at NRCs home page at <WWW.NRC.GOV> in the Reference Library.  Documents are also available through the Electronic Reading Room (NRCs ADAMS document system, or PARS) at the same web site.
 
3  Copies are available at current rates from the U.S. Government Printing Office, P.O. Box 37082, Washington, DC 20402-9328 (telephone (202)512-1800); or from the National Technical Information Service at 5285 Port Royal Road, Springfield, VA
22161; (telephone (800)553-6847; <http://www.ntis.gov/ordernow>). Copies are available for inspection or copying for a fee from the NRC Public Document Room at 11555 Rockville Pike, Rockville, MD; the PDRs mailing address is USNRC PDR,
Washington, DC 20555; telephone (301)415-4737 or (800)397-4209; fax (301)415-3548; email is PDR@NRC.GOV .
1.140-14 REFERENCES
1.
 
American Society of Mechanical Engineers, "Nuclear Power Plant Air-Cleaning Units and Components," ASME N509-1989. Reaffirmed 1996.
 
2.
 
American Society of Mechanical Engineers, "Testing of Nuclear Air-Treatment Systems,"
ASME N510-1989. Reaffirmed 1995.
 
3.
 
American Society of Mechanical Engineers, "Code on Nuclear Air and Gas Treatment,"
ASME/ANSI AG-1-1997.
 
4.


A "batch of activated carbon" is a quantity of material of the same grade, type, and series that has been homogenized to exhibit, within reason-able tolerance, the same performance and physical characteristics and for which the manufacturer can demonstrate by acceptable tests and quality control practices such uniformity.
American Society for Testing and Materials, "Standard Test Methods for Nuclear-Grade Activated Carbon," ASTM Standard D3803-1989.  Reapproved 1995.


All material in the same batch should be activated, impregnated, and otherwise treated under the same process conditions and procedures in the same process equipment and should be produced under the same manufactur- ing release and instructions.
5.


Material produced in the same charge of batch equipment constitutes a batch; material produced in different charges of the same batch equipment should be included in the same batch only if it can be homogenized as above. The maximum batch size should be 350 ftW of activated carbo
C. A. Burchsted, J. E. Kahn, and A. B. Fuller, "Nuclear Air Cleaning Handbook," Oak Ridge National Laboratory, ERDA 76-21, March 31, 1976.1
6.


====n. b See Reference ====
USNRC, "Information Relevant to Ensuring that Occupational Radiation Exposures at Nuclear Power Stations Will Be As Low As Is Reasonably Achievable," Regulatory Guide
12.C This test should be performed on base material.1.140-6 TABLE 2 LABORATORY
8.8, Revision 3, June 1978.2
TESTS FOR ACTIVATED
7.
CARBON Activated Carbon" Bed Depth b 2 inches. Air filtration system designed to operate inside primary containment.


2 inches. Air filtration system designed to operate outside the primary contain-ment, and relative humidity is controlled to 70%4 inches. Air filtration system designed to operate outside the primary contain-ment, and relative humdity is controlled to 70%.6 inches. Air filtration system designed to operate outside the primary contain-ment, and relativr;
American Society of Mechanical Engineers, Section HA, Housings, of "Code on Nuclear Air and Gas Treatment," ASME AG-1a-2000, Addenda to ASME AG-1-1997, December
humidity is controlled to 7G%.Assigned Activated Carbon Decontamination Efficiencies For Radioiodine
2000.
90%70%Laxboratory Tests for a Representativc SampleC Per Test 5.b in Table I for a methyl iodide pene-tration of less than 10%.Per Test 5.b in Table I at a rclative humidity of 70% for a methyl iodide penetration of less than 10%.Per Test 5.b in Table 1 at a relative humidity of 70%for a methyl iodide pene-tration of less than 10%.Per Test 5.b in Table I at a relative humidity of 70%for a methyl iodide penetra-tion of less than 1%.90%99%* The activated carbon, when new, should meet the specifications of regulatory position C.3.g of this guide.b Multiple beds. e.g., two 2-inch beds in series, should be treated as a single bed of aggregate depth.See regulatory position C.6.b for definition of representative sample. Testing should be performed
(1) initially, (2) at a frequency not to exceed 18 months (during a scheduled reactor shutdown is acceptable), and (3) following painting, fire, or chemical release in any ventilation zone communicating with the system in such a manner that the charcoal adsorbers could become contaminated from the fumes, chemicals, or foreign materials.


REFERENCES
8.
1. American National Standard ANSI/ASME
N509-1976, "Nuclear Power Plant Air Cleaning Units and Components." Copies may be obtained from the American Society of Mechanical Engineers, United Engineering Center, 345 East 47th Street, New York, N.Y. 10017.2. American National Standard ANSI N510-1975,"Testing of Nuclear Air Cleaning Systems,''
American Society of Mechanical Engineers.


3. ERDA 76-21, "Nuclear Air Cleaning Hand-book," Oak Ridge National Laboratory, C. A.Burchsted, J. E. Kahn, and A. B. Fuller, March 31, 1976. Copies may be obtained from the Na-tional Technical Information Service, Springfield, Va. 22161.4. ORNL-NSIC-65, "Design, Construction, and Testing of High Efficiency Air Filtration Systems for Nuclear Application," Oak Ridge National Laboratory, C. A. Burchsted and A. B. Fuller, January 1970. Copies may be obtained from the National Technical Information Service.5. Regulatory Guide 8.8, "Information Relevant to Ensuring that Occupational Radiation Exposures at Nuclear Power Stations Will Be As Low As Is Reasonably Achievable," Office of Standards Development, U.S. Nuclear Regulatory Commis-sion.6. MIL-F-51068, "Filter, Particulate.
J.K. Fretthold, HEPA Service Life Tests-Effects-Recommendations at Department of Energy Rocky Flats Environmental Technology Site, Proceedings of the 25th DOE/NRC
Nuclear Air Cleaning and Treatment Conference, NUREG/CP-0167, April 1999.3


High-Efficiency, Fire-Resistant" (latest edition), Mili-tary Specification.
4  Copies are available for inspection or copying for a fee from the NRC Public Document Room at 11555 Rockville Pike, Rockville, MD; the PDRs mailing address is USNRC PDR, Washington, DC 20555; telephone (301)415-4737 or (800)397-
4209; fax (301)415-3548; e-mail <PDR@NRC.GOV>.
5  Copies are available at current rates from the U.S. Government Printing Office, P.O. Box 37082, Washington, DC 20402-9328 (telephone (202)512-1800); or from the National Technical Information Service 5285 Port Royal Road, Springfield, VA 22161;
(telephone (800)553-6847; <http://www.ntis.gov/ordernow>.
1.140-15
9.


Copies may be obtained from the Naval Publications and Forms Center, 5801 Tabor Ave., Philadelphia, Penn. 19120.7. MIL-STD-282, "Filter Units, Protective Cloth-ing, Gas-Mask Components and Related Products: Performance-Test Methods," Military Standard, 28 May 1956. Copies may be obtained from the address given in Reference
NRC Information Notice 99-01, Deterioration of High-Efficiency Particulate Air Filters in a Pressurized Water Reactor Containment Fan Cooler Unit, January 20, 1999.4
6.8. American Conference of Governmental Industrial Hygienists, "Industrial Ventilation," 14th Edi-tion, 1976, Committee on Industrial Ventilation, P.O. Box 453, Lansing, Mich. 48902.9. ASTM D2862-70, "Test for Particle Size Distribu-tion of Granulated Activated Carbon." Copies 1.140-7 a .a may be obtained from the American Society for Testing and Materials, 1916 Race Street, Philadelphia, Penn. 19103.10. RDT Standard M16-IT, "Gas-Phase Adsorbents for Trapping Radioactive Iodine and Iodine Com-pounds." USAEC Division of Reactor Research and Development.
10.


October 1973, Oak Ridge, Tenn.37830.UNITEO STATES NUCLEAR REGULATORY
NRC Information Notice 99-34, Potential Fire Hazards in the Use of Polyalphaolefin in Testing of Air Filters, December 28, 1999.4
COMMISSION
11.
WASHINGTON, 0. C. 20555 OFFICIAL BUSINESS PENALTY FOR PRIVATE USE, S300 11. ASTM D2854-70, "Test for Apparent Density of Activated Carbon," American Society for Test-ing and Materials.


12. ASTM El 1-70, "Specifications for Wire Cloth Sieves for Testing Purposes," American Society for Testing and Materials.
Environmental Protection Agency, Toxic Substance Control Act (TSCA), Inventory for Commercial Use.5


POSTAGE AND FEES PAID U.S. NUCLEAR REGULATOR
1.140-16 VALUE/IMPACT STATEMENT
I, COMMISSION
A value/impact statement was published with the draft of this guide when it was issued for public comment (Task DG-1103, October 2000).  No changes were necessary, so a separate value/impact statement for this regulatory guide has not been prepared.  This regulatory guide does not require a backfit analysis as described in 10 CFR 50.109(c) because it does not impose a new or amended provision in the NRCs rules and regulations. A copy of the value/impact statement (ADAMS Accession Number ML003756467) is available for inspection or copying for a fee in the NRCs Public Document Room at 11555 Rockville Pike, Rockville, MD; the PDRs mailing address is USNRC PDR, Washington, DC 20555; telephone (301)415-4737 or (800)397-4209; fax
0}}
(301)415-3548; email is <PDR@NRC.GOV>.}}


{{RG-Nav}}
{{RG-Nav}}

Latest revision as of 01:53, 17 January 2025

(Revision 2), Design, Inspection, and Testing Criteria for Air Filtration and Adsorption Units of Normal Atmosphere Cleanup Systems in Light-Water-Cooled Nuclear Power Plants
ML011710150
Person / Time
Issue date: 06/30/2001
From:
Office of Nuclear Regulatory Research
To:
Segala J
References
DG-1103 RG-1.140
Download: ML011710150 (17)


Regulatory guides are issued to describe and make available to the public such information as methods acceptable to the NRC staff for implementing specific parts of the NRCs regulations, techniques used by the staff in evaluating specific problems or postulated accidents, and data needed by the NRC staff in its review of applications for permits and licenses. Regulatory guides are not substitutes for regulations, and compliance with them is not required. Methods and solutions different from those set out in the guides will be acceptable if they provide a basis for the findings requisite to the issuance or continuance of a permit or license by the Commission.

This guide was issued after consideration of comments received from the public. Comments and suggestions for improvements in these guides are encouraged at all times, and guides will be revised, as appropriate, to accommodate comments and to reflect new information or experience. Written comments may be submitted to the Rules and Directives Branch, ADM, U.S. Nuclear Regulatory Commission, Washington, DC 20555-0001.

Regulatory guides are issued in ten broad divisions: 1, Power Reactors; 2, Research and Test Reactors; 3, Fuels and Materials Facilities; 4, Environmental and Siting;

5, Materials and Plant Protection; 6, Products; 7, Transportation; 8, Occupational Health; 9, Antitrust and Financial Review; and 10, General.

Single copies of regulatory guides (which may be reproduced) may be obtained free of charge by writing the Distribution Services Section, U.S. Nuclear Regulatory Commission, Washington, DC 20555-0001, or by fax to (301)415-2289, or by email to DISTRIBUTION@NRC.GOV. Electronic copies of this guide are available on the internet at NRCs home page at <WWW.NRC.GOV> in the Reference Library under Regulatory Guides and through the Electronic Reading Room, as Accession Number ML011710150, along with other recently issued guides, at the same web site.

U.S. NUCLEAR REGULATORY COMMISSION Revision 2 June 2001 REGULATORY

GUIDE

OFFICE OF NUCLEAR REGULATORY RESEARCH

REGULATORY GUIDE 1.140

(Draft was issued as DG-1103)

DESIGN, INSPECTION, AND TESTING CRITERIA FOR

AIR FILTRATION AND ADSORPTION UNITS OF NORMAL

ATMOSPHERE CLEANUP SYSTEMS IN LIGHT-WATER-COOLED

NUCLEAR POWER PLANTS

A. INTRODUCTION

This guide provides guidance and criteria acceptable to the NRC staff for meeting the NRC's regulations with regard to the design, inspection, and testing of air filtration and adsorption units installed in the normal atmosphere cleanup systems of light-water-cooled nuclear power plants. This guide applies only to atmosphere cleanup systems designed to collect airborne radioactive materials during normal plant operation, including anticipated operational occurrences. Therefore, in this guide these systems are referred to as normal atmosphere cleanup systems. These normal atmosphere cleanup systems may consist of heaters and/or cooling coils, prefilters, high-efficiency particulate air (HEPA) filters, iodine adsorption units, fans, associated ductwork, dampers, and instrumentation. The instrumentation covered by this guide is that used to measure air flow and differential pressure.

In Appendix A, "General Design Criteria for Nuclear Power Plants," to 10 CFR Part 50,

Domestic Licensing of Production and Utilization Facilities, General Design Criteria 60 and 61 require

1.140-2 that the nuclear power plant design include means to suitably control the release of radioactive materials in gaseous effluents during normal reactor operation, including anticipated operational occurrences and fuel storage and handling operations. In addition, 10 CFR 50.34a, "Design Objectives for Equipment To Control Releases of Radioactive Material in Effluents -- Nuclear Power Reactors," and 10 CFR 50.36a, "Technical Specifications on Effluents from Nuclear Power Reactors," of 10 CFR Part 50 require that means be employed to ensure that release of radioactive material to unrestricted areas during normal reactor operation, including during expected operational occurrences, is kept as low as is reasonably achievable.

Appendix I, "Numerical Guides for Design Objectives and Limiting Conditions for Operation To Meet the Criterion As Low As Is Reasonably Achievable for Radioactive Material in Light-Water-Cooled Nuclear Power Reactor Effluents," to 10 CFR Part 50 provides guidance and numerical values for design objectives to help applicants for, and holders of, licenses for nuclear power plants meet the requirements of 10 CFR 50.34a and 50.36a. Appendix I requires that each light-water-cooled nuclear power reactor unit not exceed an annual dose design objective of 15 mrem to any organ of any individual in an unrestricted area via all exposure pathways from airborne radioactive iodine and particulate releases. Appendix I also requires that additional radwaste equipment be provided if the equipment has reasonably demonstrated technology and the cost-benefit ratio is favorable.

This guide does not apply to post-accident engineered-safety-feature (ESF) atmosphere cleanup systems that are designed to mitigate the consequences of postulated accidents.

Regulatory Guide 1.52, "Design, Inspection, and Testing Criteria for Air Filtration and Adsorption Units of Post-Accident Engineered-Safety-Feature Atmosphere Cleanup Systems in Light-Water- Cooled Nuclear Power Plants," provides guidance for these systems.

The guidance and criteria presented in this guide are not mandatory and licensees may choose not to change their licensing basis. Methods and solutions different from those set out in this guide will be acceptable when an applicant or licensee proposes an acceptable alternative method for complying with the specified portions of the NRCs regulations.

The information collections contained in this regulatory guide are covered by the requirements of 10 CFR Part 50, which were approved by the Office of Management and Budget, approval number 3150-0011. If a means used to impose an information collection does not display a currently valid OMB control number, the NRC may not conduct or sponsor, and a person is not required to respond to, the information collection.

B. DISCUSSION

Particulate filtration and radioiodine adsorption units are included in the design of the normal atmosphere cleanup systems of light-water-cooled nuclear power plants to reduce the quantities of radioactive materials in gaseous effluents released from building or containment atmospheres during normal operation, including anticipated operational occurrence

s. All such

1.140-3 cleanup systems should be designed to operate continuously under normal environmental conditions.

In this guide, cleanup systems that should operate to meet the "as low as is reasonably achievable (ALARA)" guidelines of Appendix I to 10 CFR Part 50 inside the primary containment (recirculating units) are designated as "primary systems." Primary systems generally include a containment cleanup system (kidney filtration system). Systems that operate outside the primary containment are designated as "secondary systems." Secondary systems generally include normal atmosphere cleanup systems servicing the reactor building, turbine building, radwaste building, auxiliary building, mechanical vacuum pump, main condenser air ejector, and any other release points that may contain particulate and gaseous radioiodine species.

These normal atmosphere cleanup systems should be able to withstand normal environmental conditions such as inlet concentrations of radioactive iodine up to 10-6 µCi/cm3, relative humidity of the influent stream up to 100%, temperatures of the influent stream up to

125°F (52°C), and normal atmospheric pressure. The system should be designed, inspected, and tested in such a manner that radiation levels of airborne radioactive material and radioiodine buildup on the adsorber do not degrade the performance of the filter system or any component.

Normal atmosphere cleanup system heaters are designed to heat the influent stream to reduce its relative humidity before it reaches the filters and adsorbers. HEPA filters are installed to remove particulate matter, which may be radioactive, and pass the air stream to the adsorber, which then removes gaseous iodine (elemental iodine and organic iodides) from the air stream. A

HEPA filter or a medium efficiency postfilter (as defined in Section 5.3 of ASME N509-1989 (Ref. 1)) downstream from the adsorption units collects carbon fines and provides additional protection against particulate matter release in case of failure of the upstream HEPA filter bank. It is not necessary to perform in-place leak testing on postfilters or HEPA filters downstream from the carbon adsorbers. It is advantageous for the postfilters or HEPA filters downstream from the carbon adsorbers to be installed in separate housings or to be removed from the housing (for systems with a fan downstream from the housing) during in-place leak testing of the upstream HEPA filter. This will contribute to the accuracy of the test results for the upstream HEPA filter.

The arrangement of the ductwork and the transitions between the separate housings can provide a torturous path that will aid in mixing the challenge agent. Removing the filters downstream from the carbon adsorbers will permit sampling downstream from the fan. The fan will provide the necessary mixing for an accurate test and the absences of the postfilters or HEPA filters downstream from the carbon adsorbers will prevent the challenge aerosol from being removed from the air stream. The fan is the final item in a normal atmosphere cleanup system.

Consideration should be given to installing prefilters upstream from the HEPA filters to reduce the particulate load and extend their service life.

The environmental history of the facility will affect the performance of the normal atmosphere cleanup system. Industrial contaminants, pollutants, temperature, and relative humidity contribute to the aging and weathering of filters and adsorbers and reduce their capability to perform their intended functions. Therefore, aging, weathering, and poisoning of these components, which may vary from site to site, need to be considered during design and operation.

1.140-4 Average temperature and relative humidity also vary from site to site, and the potential buildup of moisture in the adsorber warrants equal design consideration. The effects of these factors on the normal atmosphere cleanup system can be determined by a monitoring program.

All components of the normal atmosphere cleanup system need to be designed for reliable performance under the expected operating conditions. Initial testing and proper maintenance are primary factors in ensuring the reliability of the system. Consideration during the design phase of problems of system maintenance can contribute significantly to the reliability of the system by increasing the ease of such maintenance. A layout that provides accessibility and sufficient working space to safely and efficiently perform the required maintenance functions is of particular importance in the design. Periodic inspection and testing during operation to verify the efficiency of the components is another important means of ensuring reliability. Built-in features that will facilitate convenient in-place testing are important in system design.

Standards acceptable to the NRC staff for the design and testing of normal atmosphere cleanup systems include those portions of ASME N509-1989, "Nuclear Power Plant Air-Cleaning Units and Components" (Ref. 1), ASME N510-1989, "Testing of Nuclear Air-Treatment Systems"

(Ref. 2), and ASME AG-1-1997, "Code on Nuclear Air and Gas Treatment" (Ref. 3) that are referenced in this guide and ASTM D3803-1989, "Standard Test Methods for Nuclear-Grade Activated Carbon" (Ref. 4).

If a referenced standard has been incorporated separately into the NRCs regulations, licensees and applicants must comply with that standard as set forth in the regulation. If the referenced standard has been endorsed in a regulatory guide, the standard constitutes a method acceptable to the NRC staff for meeting a regulatory requirement as described in the regulatory guide. If a referenced standard has been neither incorporated into the NRCs regulations nor endorsed in a regulatory guide, licensees and applicants may consider and use the information in the referenced standard if appropriately justified, consistent with current regulatory practice.

C. REGULATORY POSITION

1.

GENERAL DESIGN AND TESTING CRITERIA

ASME AG-1-1997, Code on Nuclear Air and Gas Treatment (Ref. 3), and ASME N509-

1989, Nuclear Power Plant Air-Cleaning Units and Components (Ref. 1) provide guidance that is acceptable to the NRC staff for the performance, design, construction, acceptance testing, and quality assurance of equipment used as components in nuclear safety-related or ESF air and gas treatment systems in nuclear power plants. Normal atmosphere cleanup systems designed to ASME N509-1989 (Ref. 1) (or its earlier versions) and tested to ASME N510-1989 (Ref. 2) (or its earlier versions) are considered adequate to protect public health and safety.

1.140-5

2.

ENVIRONMENTAL DESIGN CRITERIA

2.1.

The design of each normal atmosphere cleanup system should be based on the anticipated range of operating parameters of temperature, pressure, relative humidity, and radiation levels during normal plant operations, including anticipated operational occurrences.

2.2.

If the normal atmosphere cleanup system is located in an area of high radiation during normal plant operation, adequate shielding of components and personnel from the radiation source should be provided.

2.3.

The operation of any normal atmosphere cleanup system should not degrade the expected operation of any ESF system that is required to operate after a design basis accident.

2.4.

The design of the normal atmosphere cleanup system should consider any sig- nificant contaminants such as dusts, chemicals, excessive moisture, or other particulate matter that could degrade the cleanup system's operation.

3.

SYSTEM DESIGN CRITERIA

Normal atmosphere cleanup systems should be designed in accordance with Section 4.0 of ASME N509-1989 (Ref. 1) and ASME AG-1-1997 (Ref. 3) as modified and supplemented by the following:

3.1.

Normal atmosphere cleanup systems need not be redundant nor designed to Seismic Category I classification, but they should consist of at least the following components: (1) HEPA

filters before the adsorbers, (2) iodine adsorbers (impregnated activated carbon), (3) fans, and (4)

interspersed ducts, dampers, and related instrumentation. To reduce the particulate load on the HEPA filters and extend their service life, the installation of prefilters upstream from the initial HEPA section is suggested. Consideration should also be given to the installation of a HEPA filter or medium efficiency postfilter (as defined in Section 5.3 of ASME N509-1989 (Ref. 1))

downstream from carbon adsorbers to retain carbon fines. Heaters or cooling coils or both may be used when the humidity is to be controlled before filtration. Whenever a normal atmosphere cleanup system is designed to remove only particulate matter, a component for iodine adsorption need not be included.

3.2.

To ensure reliable in-place testing, the volumetric air-flow rate of a single cleanup unit should be limited to approximately 30,000 cubic feet per minute. If a total system air flow in excess of this rate is required, multiple units should be used.

3.3.

Each normal atmosphere cleanup system should be instrumented to monitor and alarm pertinent pressure drops and flow rates in accordance with the recommendations of Section

5.6 of ERDA 76-21 (Ref. 5) and Section 4.9 of ASME N509-1989 (Ref. 1).

1.140-6

3.4.

To maintain the radiation exposure to operating and maintenance personnel as low as is reasonably achievable (ALARA), normal atmosphere cleanup systems and components should be designed to control leakage and facilitate maintenance, inspection, and testing in accordance with the guidance in Regulatory Guide 8.8, "Information Relevant to Ensuring that Occupational Radiation Exposures at Nuclear Power Stations Will Be As Low As Is Reasonable Achievable" (Ref. 6).

3.5.

Outdoor air intake openings should be equipped with louvers, grills, screens, or similar protective devices to minimize the effects of high winds, rain, snow, ice, trash, and other contaminants on the operation of the system. The outdoor air intake openings should be located to minimize the effects of possible onsite plant contaminants, such as the diesel generator exhaust. If the atmosphere surrounding the plant could contain significant environmental contaminants, such as dusts and residues from smoke-cleanup systems from adjacent coal-burning power plants or industry, or is a salty environment near an ocean, the design of the system should consider these contaminants and prevent them from affecting the operation of any normal atmosphere cleanup system.

3.6.

Normal atmosphere cleanup system housings and ductwork should be designed to exhibit, on test, a maximum total leakage rate as defined in Article SA-4500 of ASME AG-1-1997 (Ref. 3). Duct and housing leak tests should be performed in accordance with Section TA of ASME AG-1-1997.

4.

COMPONENT DESIGN CRITERIA AND QUALIFICATION TESTING

Components of normal atmosphere cleanup systems should be designed, constructed, and tested in accordance with Division II of ASME AG-1-1997 (Ref. 3), as modified and supplemented by the following.

4.1.

Prefilters that are used in the normal atmosphere cleanup system should be designed, constructed, and tested in accordance with Section FB of ASME AG-1-1997.

4.2.

Air heaters should be designed, constructed, and tested in accordance with Section CA of ASME AG-1-1997.

4.3.

The HEPA filters should be designed, constructed, and tested in accordance with Section FC of ASME AG-1-1997. Each HEPA filter should be tested for penetration of a challenge aerosol such as dioctyl phthalate (DOP) in accordance with Section TA of ASME AG-1-

1997.

4.4.

The HEPA filter and Type II adsorber cell mounting frames should be designed and constructed in accordance with Section FG of ASME AG-1-1997.

4.5.

Filter and adsorber sections should be arranged in accordance with Section 4.4 of ERDA 76-21 (Ref. 5) and Section HA, Housings, of ASME AG-1a-2000 (Ref. 7).

1 Activated carbon is typically impregnated with a chemical compound or compounds to enhance radioiodine retention, particularly under conditions of high temperatures and humidity. Typical impregnants include iodides such as potassium iodide and triiodide, amines such as triethylenediamine (TEDA), and combinations thereof.

1.140-7

4.6.

System filter housings, including floors and doors, and electrical conduits, drains, and piping installed inside filter housings should be designed and constructed in accordance with Section 5.6 of ASME N509-1989 (Ref. 1) and Section HA, ASME AG-1a-2000 (Ref. 7).

4.7.

Adsorption units function efficiently at a relative humidity of 70% or less. If the relative humidity of the atmosphere entering the air cleanup system is expected to be greater than

70% during normal reactor operation, heaters or cooling coils should be designed to reduce the relative humidity of the atmosphere entering the adsorption unit to 70% or less. Heaters should be designed, constructed, and tested in accordance with Section CA of ASME AG-1-1997 (Ref. 3)

exclusive of sizing criteria.

4.8.

Adsorber cells should be designed, constructed, and tested in accordance with Section FD for Type II Adsorber cells or Section FE for Type III Adsorber cells of ASME AG-1-

1997.

The design of the adsorber section should consider possible iodine desorption and adsorbent auto-ignition that may result from radioactivity-induced heat in the adsorbent and concomitant temperature rise. Acceptable designs include a low-flow air bleed system, cooling coils, water sprays for the adsorber section, or other cooling mechanisms.

When a water-based fire suppression or prevention (cooling) system is installed in the normal atmosphere cleanup system housing, the fire system should be manually actuated unless there is a reasonable probability that the iodine desorption and adsorbent auto-ignition could occur in the housing, in which case the fire system should have both automatic and manual actuation.

The fire system should use open spray nozzles or devices of sufficient size, number, and location to provide complete coverage over the entire surface of the combustible filter media. The fire system should be hard piped and supplied with a reliable source of water at adequate pressure and volume. The location of the manual release (or valve) for the fire system should be remote from the cleanup system housing and should be consistent with the ALARA guidance in Regulatory Guide 8.8 (Ref. 6). Automatic fire systems should include a reliable means of detection to actuate the system. Detection can be accomplished by a mechanical or electrical device including, but not limited to, thermal, carbon monoxide, or smoke. Cross-zoning of detectors is acceptable. Manual fire systems should include a reliable means of internal monitoring for determining when to manually actuate the fire systems. The monitoring indication should be remote from the cleanup system housing in accordance with ALARA practices.

4.9.

The adsorber section of the normal atmosphere cleanup system may contain any adsorbent material demonstrated to remove gaseous iodine (elemental iodine and organic iodides)

from air at the required efficiency. However, since impregnated activated carbon1 is used almost exclusively, only impregnated activated carbon is discussed in this guide.

2 A batch of activated carbon or a batch of impregnated activated carbon is a quantity of adsorbent, not to exceed 10 cubic meters (or 350 cubic feet), of the same grade or type that has been produced under the same manufacturers production designation using a consistent manufacturing procedure and equipment, and that has been homogenized to exhibit the same physical properties and performance characteristics throughout the mass. (See Article FF-1130 of ASME AG-1-1997).

3 A "lot of activated carbon" or a "lot of impregnated activated carbon" is a quantity of adsorbent consisting of one or more batches of adsorbent that constitute and satisfy a purchase order. (See Article FF-1130 of ASME AG-1-1997).

1.140-8 Each original or replacement batch or lot of impregnated activated carbon used in the adsorber section should meet Section FF of ASME AG-1-1997 (Ref. 3).2,3 A test performed as a

"qualification test" should be interpreted to mean a test that establishes the suitability of a manufacturer's product for a generic application, normally a one-time test establishing typical performance of the product. Tests not specifically identified as being performed only for qualification purposes should be interpreted as "batch tests." Batch tests are tests to be made on each production batch of product to establish suitability for a specific application.

If impregnated activated carbon is used as the adsorbent, the adsorber system should be designed for an average atmosphere residence time of 0.25 seconds per two inches of adsorbent bed. Sections FD and FE of ASME AG-1-1997 should be used to determine the residence time.

If an adsorbent other than impregnated activated carbon is proposed or if the mesh size distribution or other physical properties of the impregnated activated carbon are different from the specifications above, the proposed adsorbent should have the capability to perform as well as or better than activated carbon that satisfies the specifications in Article FF of ASME AG-1-1997.

If sample canisters are used, they should be designed in accordance with Appendix A to ASME N509-1989 (Ref. 1).

4.10.

Ductwork associated with the normal atmosphere cleanup system should be de- signed, constructed, and tested in accordance with Section SA of ASME AG-1-1997.

4.11.

Ducts and housings should be laid out with a minimum of ledges, protrusions, and crevices that could collect dust and moisture and that could impede personnel or create a hazard to them in the performance of their work. Turning vanes or other air flow distribution devices should be installed where required to ensure representative air flow measurement and uniform flow distri- bution through cleanup components.

4.12.

Dampers should be designed, constructed, and tested in accordance with Section DA of ASME AG-1-1997.

4.13.

The system fan and motor, mounting, and ductwork connections should be designed, constructed, and tested in accordance with ASME AG-1-1997 in Section BA for Blowers and Section SA for Ducts. The fan and motor used in the normal atmosphere cleanup system should be capable of operating under the environmental conditions postulated for its use.

4 In 1998, the Department of Energy (DOE) presented the results of its HEPA filter deterioration research at the 25th DOE/NRC

Nuclear Air Cleaning and Treatment Conference (Ref. 8). The results of this research demonstrated that wetting of the filter medium significantly reduces its tensile strength, which is not fully recovered after drying. In addition, further water exposures resulted in additional losses in filter media tensile strength. (See NRC Information Notice 99-01, Ref. 9).

5 Painting, fire, or chemical release is not communicating with the HEPA filter or adsorber if the ESF atmosphere cleanup system is not in operation, the isolation dampers for the system are closed, and there is no pressure differential across the filter housing. This provides reasonable assurance that air is not passing through the filters and adsorbers. A program should be developed and consistently applied that defines the terms painting, fire, and chemical release in terms of the potential for degrading the HEPA filters and adsorbers. This program should be based on a well-documented, sound and conservative technical basis (i.e., the criteria should overestimate the potential damage to the filter and adsorber).

1.140-9

5.

MAINTAINABILITY CRITERIA

Provisions for maintaining normal atmosphere cleanup systems should be incorporated in the system design in accordance with Section 4.8 of ASME N509-1989 (Ref. 1) and Section HA of ASME AG-1a-2000 (Ref. 7) as supplemented by the following.

5.1.

Accessibility of components and maintenance should be considered in the design of normal atmosphere cleanup systems in accordance with Section 2.3.8 of ERDA 76-21 (Ref. 5) and Section HA of ASME AG-1a-2000 (Ref. 7). For ease of inspection and maintenance, the system design should provide for a minimum of 3 feet from mounting frame to mounting frame between banks of components. If components are to be replaced, the dimensions to be provided should be the maximum length of the component plus a minimum of 3 feet.

5.2.

The cleanup components (i.e., HEPA filters, prefilters, and adsorbers) that are used during construction of the ventilation systems should be replaced before the system is declared operable.

6.

IN-PLACE TESTING CRITERIA

Initial in-place testing of normal atmosphere cleanup systems should be performed in accordance with Section TA of ASME AG-1-1997 (Ref. 3). Periodic, in-place testing of normal atmosphere cleanup systems and components should be performed in accordance with ASME

N510-1989 (Ref. 2) as modified and supplemented by the following:

6.1.

A visual inspection of the normal atmosphere cleanup system and all associated components should be performed in accordance with Section 5 of ASME N510-1989.

6.2.

In-place aerosol leak tests for HEPA filters upstream from the carbon adsorbers in normal atmosphere cleanup systems should be performed (1) initially, (2) at least once each 24 months, (3) after each partial or complete replacement of a HEPA filter bank, (4) following detection of, or evidence of, penetration or intrusion of water or other material into any portion of a normal atmosphere cleanup system that may have an adverse effect on the functional capability of the filters,4 and (5) following painting, fire, or chemical release in any ventilation zone communicating with the system that may have an adverse effect on the functional capability of the system.5 The test should be performed in accordance with Section 10 of ASME N510-1989 (Ref.

6 In Section FD-1130 of ASME AG-1-1997 (Ref. 3), penetration is defined as the exit concentration of a given gas from an air cleaning device, expressed as a percentage of inlet concentration. In Section 3 of ASME N509-1989 (Ref. 1), bypass is defined as a pathway through which contaminated air can escape treatment by the installed HEPA or adsorber banks. Examples are leaks in filters and filter mounting frames, defective or inefficient isolation dampers that result in uncontrolled flow through adjacent plenums, and unsealed penetrations for electrical conduits, pipes, floor drains, etc.

7 Care should be taken to ensure that the aerosol generator is compatible with the selected alternative challenge agent (see NRC

Information Notice 99-34, Ref. 10).

1.140-10

2). The leak test should confirm a combined penetration and leakage (or bypass)6 of the normal atmosphere cleanup system of less than 0.05% of the challenge aerosol at rated flow +/-10%. A

filtration system satisfying this condition can be considered to warrant a 99% removal efficiency for particulates.

HEPA filter sections in normal atmosphere cleanup systems that fail to satisfy the appropriate leak-test conditions should be examined to determine the location and cause of leaks.

Repairs, such as alignment of filter frames and tightening of filter hold-down bolts, may be made;

however, repair of defective, damaged, or torn filter media by patching or using caulking materials is not recommended in normal atmosphere cleanup systems, and such filters should be replaced and not repaired. HEPA filters that fail to satisfy test conditions should be replaced with filters qualified pursuant to Regulatory Position 4.3 of this guide. After repairs or filter replacement, the normal atmosphere cleanup system should be retested as described above in this Regulatory Position.

In accordance with ASME N510-1989 (Ref. 2) and Article TA-1000 of ASME AG-1-1997 (Ref. 3), the standard challenge aerosol used in the in-place leak testing of HEPA filters is polydisperse droplets of dioctyl phthalate (DOP), also known as di-2-ethylhexyl-phthalate (DEHP).

The 0.3 micrometer monodisperse DOP aerosol is used for efficiency testing of individual HEPA

filters by manufacturers. Alternative challenge agents7 may be used to perform in-place leak testing of HEPA filters when their selection is based on the following.

1. The challenge aerosol has the approximate light scattering droplet size specified in Article TA-1130 of ASME AG-1-1997

2. The challenge aerosol has the same in-place leak test results as DOP.

3. The challenge aerosol has similar lower detection limit, sensitivity, and precision as DOP.

4. The challenge aerosol causes no degradation of the HEPA filter or the other normal air cleaning system components under test conditions.

5. The challenge aerosol is listed in the Environmental Protection Agency's Toxic Substance Control Act (TSCA) (Ref. 11) inventory for commercial use.

6.3.

In-place leak testing for adsorbers should be performed (1) initially, (2) at least once each 24 months, (3) following removal of an adsorber sample for laboratory testing if the integrity of the adsorber section is affected, (4) after each partial or complete replacement of carbon adsorber in an adsorber section, (5) following detection of, or evidence of, penetration or intrusion of water or other material into any portion of a normal atmosphere cleanup system that may have an adverse effect on the functional capability of the adsorbers, and (6) following painting, fire, or

1.140-11 chemical release in any ventilation zone communicating with the system that may have an adverse effect on the functional capability of the system.5 The test should be performed in accordance with Section 11 of ASME N510-1989 (Ref. 2). The leak test should confirm a combined penetration and leakage (or bypass)6 of the adsorber section of 0.05% or less of the challenge gas at rated flow+/-10%.

Adsorber sections that fail to satisfy the appropriate leak-test conditions should be examined to determine the location and cause of leaks. Repairs, such as alignment of adsorber cells, tightening of adsorber cell hold-down bolts, or tightening of test canister fixtures, may be made; however, the use of temporary patching material on adsorbers, filters, housings, mounting frames, or ducts should not be allowed. After repairs or adjustments have been made, the adsorber sections should be retested as described above in this Regulatory Position.

In accordance with ASME N510-1989 (Ref. 2) and Section TA of ASME AG-1-1997 (Ref.

3), the standard challenge gas used in the in-place leak testing of adsorbers is Refrigerant-11 (trichloromonofluoromethane). Alternative challenge gases may be used to perform in-place leak testing of adsorbers when their selection is based on meeting the characteristics specified in Appendix TA-C of ASME AG-1-1997.

6.4.

If any welding repairs are necessary on, within, or adjacent to the ducts, housing, or mounting frames, the HEPA filters and adsorbers should be removed from the housing (or otherwise protected) prior to performing such repairs. The repairs should be completed prior to re- installation of filters and adsorbers; the system should then be visually inspected and leak tested as in Regulatory Positions 6.2, 6.3, and 6.4.

7.

LABORATORY TESTING CRITERIA FOR ACTIVATED CARBON

7.1.

The activated carbon adsorber section of the normal atmosphere cleanup system should be assigned the decontamination efficiencies given in Table 1 for radioiodine if the following conditions are met:

1.

The adsorber section meets the conditions given in Regulatory Position 6.3 of this guide,

2.

New activated carbon meets the physical property specifications given in Regulatory Position 4.9 of this guide, and

3.

Representative samples of used activated carbon pass the laboratory tests given in Table 1 of this guide.

If the activated carbon fails to meet any of the above conditions, it should not be used in adsorption units.

7.2.

The efficiency of the activated carbon adsorber section should be determined by laboratory testing of representative samples of the activated carbon exposed simultaneously to the same service conditions as the adsorber section. Each representative sample should be not less

1.140-12 than 2 inches in both length and diameter, and each sample should have the same qualification and batch test characteristics as the system adsorbent. There should be a sufficient number of representative samples located in parallel with the adsorber section to estimate the amount of penetration of the system adsorbent throughout its service life. The design of the samples should be in accordance with Appendix A to ASME N509-1989 (Ref. 1). Where system activated carbon is greater than 2 inches deep, each representative sampling station should consist of enough 2-inch samples in series to equal the thickness of the system adsorbent. Once representative samples are removed for laboratory testing, their positions in the sampling array should be blocked off.

Sampling and analysis should be performed (1) initially, (2) at intervals of approximately

24 months, (3) following painting, fire, or chemical release in any ventilation zone communicating with the system that may have an adverse effect on the functional capability of the carbon media,5 and (4) following detection of, or evidence of, penetration of water or other material into any portion of the filter system that may have an adverse effect on the functional capability of the carbon media.

Laboratory tests of representative samples should be conducted, as indicated in Table 1 of this guide, with the test gas flow in the same direction as the flow during service conditions.

Similar laboratory tests should be performed on an adsorbent sample before loading into the adsorbers to establish an initial point for comparison of future test results. The activated carbon adsorber section should be replaced with new unused activated carbon meeting the physical property specifications given in Regulatory Position 4.9 of this guide if (1) testing in accordance with Table 1 results in a representative sample that fails to pass the acceptance criterion or (2) no representative sample is available for testing.

D. IMPLEMENTATION

The purpose of this section is to provide information to applicants and licensees regarding the NRC staff's plans for using this regulatory guide.

Except in those cases in which an applicant or licensee proposes an acceptable alternative method for complying with specified portions of the NRC's regulations, the methods described in this guide, which reflect public comments, will be used by the NRC staff in its evaluation of submittals in connection with the design, inspection, and testing of normal atmosphere cleanup systems for the following light-water-cooled nuclear power plants:

1.

Plants for which the construction permit or license application is docketed after the issue date of this guide;

2.

Plants for which the licensee voluntarily commits to the provisions of this guide.

1.140-13 Table 1: Laboratory Tests For Activated Carbon Activated Carbona Total Bed Depthb Maximum Assigned Activated Carbon Decontamination Efficiencies Methyl Iodide Penetration Acceptance Criterion for Representative Sample

2 inches Elemental iodine Organic iodide

95%

95%

Penetration 5% when tested in accordance with ASTM D-3803-

1989 (Ref. 4)

4 inches or greater Elemental iodine Organic iodide

99%

99%

Penetration 1% when tested in accordance with ASTM D-3803-

1989 (Ref. 4)

a The activated carbon, when new, should meet the specifications of Regulatory Position 4.9 of this guide.

b Multiple beds, e.g., two 2-inch beds in series, should be treated as a single bed of aggregate depth. It is advantageous when series beds are located in separate housings and individually in-place leak tested. This aids in mixing the challenge agent and contributes to the accuracy of the test results.

NOTES:

(1) Credited decontamination efficiencies (a portion of which includes bypass leakage) are based on 0.25 second residence time per 2-inch bed depth.

(2) Organic iodide and elemental iodine are the forms of iodine that are expected to be absorbed by activated carbon.

Organic iodide is more difficult for activated carbon to adsorb than elemental iodine. Therefore, the laboratory test to determine the performance of the activated carbon adsorber is based on organic iodide. Methyl iodide is the organic form of iodine that is used in the laboratory test.

(3) This Table 1 provides acceptable decontamination efficiencies and methyl iodide test penetrations of used activated carbon samples for laboratory testing. Laboratory tests are conducted in accordance with ASTM D3803-

1989 (Ref. 4). Tests are conducted at a temperature of 30°C and relative humidity of 95%, except a relative humidity of 70% is used when the air entering the carbon adsorber is maintained at less than or equal to 70% relative humidity.

(4) See Appendix A to ASME N509-1989 (Ref. 1) for the definition of a representative sample. Testing should be performed at the frequencies specified in Regulatory Position 7.2 of this guide. Testing should be performed in accordance with ASTM D3803-1989 (Ref. 4) at a temperature of 30°C and a relative humidity of 95% (or 70% with humidity control). Humidity control can be provided by heaters or an analysis that demonstrates that the air entering the carbon will be maintained less than or equal to 70% relative humidity.

1 Copies may be purchased from the National Technical Information Service by writing NTIS, 5285 Port Royal Road, Springfield, VA 22161; telephone (703)487-4650; online <http://www.ntis.gov/ordernow>.

2 Single copies of regulatory guides, both active and draft, may be obtained free of charge by writing the Reproduction and Distribution Services Section, OCIO, USNRC, Washington, DC 20555-0001, or by fax to (301)415-2289, or by email to

<DISTRIBUTION@NRC.GOV>. Active guides may also be purchased from the National Technical Information Service on a standing order basis. Details on this service may be obtained by writing NTIS, 5285 Port Royal Road, Springfield, VA 22161;

telephone (800)553-6847; online <http://www.ntis.gov/ordernow>. Copies of certain guides and many other NRC documents are available electronically on the internet at NRCs home page at <WWW.NRC.GOV> in the Reference Library. Documents are also available through the Electronic Reading Room (NRCs ADAMS document system, or PARS) at the same web site.

3 Copies are available at current rates from the U.S. Government Printing Office, P.O. Box 37082, Washington, DC 20402-9328 (telephone (202)512-1800); or from the National Technical Information Service at 5285 Port Royal Road, Springfield, VA

22161; (telephone (800)553-6847; <http://www.ntis.gov/ordernow>). Copies are available for inspection or copying for a fee from the NRC Public Document Room at 11555 Rockville Pike, Rockville, MD; the PDRs mailing address is USNRC PDR,

Washington, DC 20555; telephone (301)415-4737 or (800)397-4209; fax (301)415-3548; email is PDR@NRC.GOV .

1.140-14 REFERENCES

1.

American Society of Mechanical Engineers, "Nuclear Power Plant Air-Cleaning Units and Components," ASME N509-1989. Reaffirmed 1996.

2.

American Society of Mechanical Engineers, "Testing of Nuclear Air-Treatment Systems,"

ASME N510-1989. Reaffirmed 1995.

3.

American Society of Mechanical Engineers, "Code on Nuclear Air and Gas Treatment,"

ASME/ANSI AG-1-1997.

4.

American Society for Testing and Materials, "Standard Test Methods for Nuclear-Grade Activated Carbon," ASTM Standard D3803-1989. Reapproved 1995.

5.

C. A. Burchsted, J. E. Kahn, and A. B. Fuller, "Nuclear Air Cleaning Handbook," Oak Ridge National Laboratory, ERDA 76-21, March 31, 1976.1

6.

USNRC, "Information Relevant to Ensuring that Occupational Radiation Exposures at Nuclear Power Stations Will Be As Low As Is Reasonably Achievable," Regulatory Guide 8.8, Revision 3, June 1978.2

7.

American Society of Mechanical Engineers, Section HA, Housings, of "Code on Nuclear Air and Gas Treatment," ASME AG-1a-2000, Addenda to ASME AG-1-1997, December

2000.

8.

J.K. Fretthold, HEPA Service Life Tests-Effects-Recommendations at Department of Energy Rocky Flats Environmental Technology Site, Proceedings of the 25th DOE/NRC

Nuclear Air Cleaning and Treatment Conference, NUREG/CP-0167, April 1999.3

4 Copies are available for inspection or copying for a fee from the NRC Public Document Room at 11555 Rockville Pike, Rockville, MD; the PDRs mailing address is USNRC PDR, Washington, DC 20555; telephone (301)415-4737 or (800)397-

4209; fax (301)415-3548; e-mail <PDR@NRC.GOV>.

5 Copies are available at current rates from the U.S. Government Printing Office, P.O. Box 37082, Washington, DC 20402-9328 (telephone (202)512-1800); or from the National Technical Information Service 5285 Port Royal Road, Springfield, VA 22161;

(telephone (800)553-6847; <http://www.ntis.gov/ordernow>.

1.140-15

9.

NRC Information Notice 99-01, Deterioration of High-Efficiency Particulate Air Filters in a Pressurized Water Reactor Containment Fan Cooler Unit, January 20, 1999.4

10.

NRC Information Notice 99-34, Potential Fire Hazards in the Use of Polyalphaolefin in Testing of Air Filters, December 28, 1999.4

11.

Environmental Protection Agency, Toxic Substance Control Act (TSCA), Inventory for Commercial Use.5

1.140-16 VALUE/IMPACT STATEMENT

A value/impact statement was published with the draft of this guide when it was issued for public comment (Task DG-1103, October 2000). No changes were necessary, so a separate value/impact statement for this regulatory guide has not been prepared. This regulatory guide does not require a backfit analysis as described in 10 CFR 50.109(c) because it does not impose a new or amended provision in the NRCs rules and regulations. A copy of the value/impact statement (ADAMS Accession Number ML003756467) is available for inspection or copying for a fee in the NRCs Public Document Room at 11555 Rockville Pike, Rockville, MD; the PDRs mailing address is USNRC PDR, Washington, DC 20555; telephone (301)415-4737 or (800)397-4209; fax

(301)415-3548; email is <PDR@NRC.GOV>.