MILLSTONE POWER STATION, UNIT NO. 3 - RESPONSE TO GENERIC LETTER 2004-01, REQUIREMENTS FOR STEAM GENERATOR TUBE INSPECTIONS (TAC NO. MC4830)
MILLSTONE POWER STATION, UNIT NO. 3 - RESPONSE TO GENERIC LETTER 2004-01, REQUIREMENTS FOR STEAM GENERATOR TUBE INSPECTIONS (TAC NO. MC4830)  


==Dear Mr. Christian:==
==Dear Mr. Christian:==
On August 30, 2004, the Nuclear Regulatory Commission (NRC) issued Generic Letter (GL) 2004-01, Requirements For Steam Generator Tube Inspections. The purpose of GL 2004-01 was to obtain information that would enable the NRC staff to determine whether licensees steam generator (SG) tube inspection programs comply with the existing tube inspection requirements (the plant technical specifications in conjunction with Appendix B to Title 10 of the Code of Federal Regulations Part 50).
On August 30, 2004, the Nuclear Regulatory Commission (NRC) issued Generic Letter (GL) 2004-01, Requirements For Steam Generator Tube Inspections. The purpose of GL 2004-01 was to obtain information that would enable the NRC staff to determine whether licensees steam generator (SG) tube inspection programs comply with the existing tube inspection requirements (the plant technical specifications in conjunction with Appendix B to Title 10 of the Code of Federal Regulations Part 50).
By letter dated October 29, 2004, you responded to GL 2004-01 for Millstone Power Station, Unit No. 3. The staffs review of your response to the GL did not identify any concerns with the inspection practices employed at Millstone Power Station, Unit No. 3. The staff, therefore, concludes that your SG tube inspection practices are in compliance with the existing tube inspection requirements.
By {{letter dated|date=October 29, 2004|text=letter dated October 29, 2004}}, you responded to GL 2004-01 for Millstone Power Station, Unit No. 3. The staffs review of your response to the GL did not identify any concerns with the inspection practices employed at Millstone Power Station, Unit No. 3. The staff, therefore, concludes that your SG tube inspection practices are in compliance with the existing tube inspection requirements.
Sincerely,
Sincerely,  
                                            /RA/
/RA/
George Wunder, Project Manager, Section 2 Project Directorate I Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket No. 50-423 cc: See next page
George Wunder, Project Manager, Section 2 Project Directorate I Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket No. 50-423 cc: See next page


Line 39: Line 38:


==Dear Mr. Christian:==
==Dear Mr. Christian:==
On August 30, 2004, the Nuclear Regulatory Commission (NRC) issued Generic Letter (GL) 2004-01, Requirements For Steam Generator Tube Inspections. The purpose of GL 2004-01 was to obtain information that would enable the NRC staff to determine whether licensees steam generator (SG) tube inspection programs comply with the existing tube inspection requirements (the plant technical specifications in conjunction with Appendix B to Title 10 of the Code of Federal Regulations Part 50).
On August 30, 2004, the Nuclear Regulatory Commission (NRC) issued Generic Letter (GL) 2004-01, Requirements For Steam Generator Tube Inspections. The purpose of GL 2004-01 was to obtain information that would enable the NRC staff to determine whether licensees steam generator (SG) tube inspection programs comply with the existing tube inspection requirements (the plant technical specifications in conjunction with Appendix B to Title 10 of the Code of Federal Regulations Part 50).
By letter dated October 29, 2004, you responded to GL 2004-01 for Millstone Power Station, Unit No. 3 (Millstone 3). The staffs review of your response to the GL did not identify any concerns with the inspection practices employed at Millstone 3. The staff, therefore, concludes that your SG tube inspection practices are in compliance with the existing tube inspection requirements.
By {{letter dated|date=October 29, 2004|text=letter dated October 29, 2004}}, you responded to GL 2004-01 for Millstone Power Station, Unit No. 3 (Millstone 3). The staffs review of your response to the GL did not identify any concerns with the inspection practices employed at Millstone 3. The staff, therefore, concludes that your SG tube inspection practices are in compliance with the existing tube inspection requirements.
Sincerely,
Sincerely,  
                                              /RA/
/RA/
George Wunder, Project Manager, Section 2 Project Directorate I Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket No. 50-423 cc: See next page DISTRIBUTION:
George Wunder, Project Manager, Section 2 Project Directorate I Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket No. 50-423 cc: See next page DISTRIBUTION:
PUBLIC                 OGC             PDI-2 R/F             ACRS         JTerrell JUhle                 CRaynor         CAnderson, RI         MBanerjee DRoberts               GWunder         MYoder                 PKlein DOCUMENT NAME: ML051590003 OFFICE     PDI-2/PM       PDI-2/LA         PDI-2/SC NAME       GWunder         CRaynor           VNerses for DRoberts DATE       6/16/05         6/15/05           6/17/05 OFFICIAL RECORD COPY
PUBLIC OGC PDI-2 R/F ACRS JTerrell JUhle CRaynor CAnderson, RI MBanerjee DRoberts GWunder MYoder PKlein DOCUMENT NAME: ML051590003 OFFICE PDI-2/PM PDI-2/LA PDI-2/SC NAME GWunder CRaynor VNerses for DRoberts DATE 6/16/05 6/15/05 6/17/05 OFFICIAL RECORD COPY


Millstone Power Station, Unit No. 3 cc:
Millstone Power Station, Unit No. 3 cc:
Lillilan M. Cuoco, Esquire             P.O. Box 426 Senior Counsel                         Ludlow, MA 01056 Dominion Resources Services, Inc.
Lillilan M. Cuoco, Esquire Senior Counsel Dominion Resources Services, Inc.
Building 475, 5th Floor               Mr. J. Alan Price Rope Ferry Road                       Site Vice President Waterford, CT 06385                   Dominion Nuclear Connecticut, Inc.
Building 475, 5th Floor Rope Ferry Road Waterford, CT 06385 Edward L. Wilds, Jr., Ph.D.
Building 475, 5th Floor Edward L. Wilds, Jr., Ph.D.           Rope Ferry Road Director, Division of Radiation       Waterford, CT 06385 Department of Environmental Protection 79 Elm Street                         Mr. Chris Funderburk Hartford, CT 06106-5127               Director, Nuclear Licensing and Operations Support Regional Administrator, Region I       Dominion Resources Services, Inc.
Director, Division of Radiation Department of Environmental Protection 79 Elm Street Hartford, CT 06106-5127 Regional Administrator, Region I U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 First Selectmen Town of Waterford 15 Rope Ferry Road Waterford, CT 06385 Mr. John Markowicz Co-Chair Nuclear Energy Advisory Council 9 Susan Terrace Waterford, CT 06385 Mr. Evan W. Woollacott Co-Chair Nuclear Energy Advisory Council 128 Terry's Plain Road Simsbury, CT 06070 Senior Resident Inspector Millstone Power Station c/o U.S. Nuclear Regulatory Commission P. O. Box 513 Niantic, CT 06357 Ms. Nancy Burton 147 Cross Highway Redding Ridge, CT 00870 Mr. Joseph Roy, Director of Operations Massachusetts Municipal Wholesale Electric Company Moody Street P.O. Box 426 Ludlow, MA 01056 Mr. J. Alan Price Site Vice President Dominion Nuclear Connecticut, Inc.
U.S. Nuclear Regulatory Commission     5000 Dominion Boulevard 475 Allendale Road                     Glen Allen, VA 23060-6711 King of Prussia, PA 19406 Mr. David W. Dodson First Selectmen                       Licensing Supervisor Town of Waterford                     Dominion Nuclear Connecticut, Inc.
Building 475, 5th Floor Rope Ferry Road Waterford, CT 06385 Mr. Chris Funderburk Director, Nuclear Licensing and Operations Support Dominion Resources Services, Inc.
15 Rope Ferry Road                    Building 475, 5th Floor Waterford, CT 06385                    Rope Ferry Road Waterford, CT 06385 Mr. John Markowicz Co-Chair Nuclear Energy Advisory Council 9 Susan Terrace Waterford, CT 06385 Mr. Evan W. Woollacott Co-Chair Nuclear Energy Advisory Council 128 Terry's Plain Road Simsbury, CT 06070 Senior Resident Inspector Millstone Power Station c/o U.S. Nuclear Regulatory Commission P. O. Box 513 Niantic, CT 06357 Ms. Nancy Burton 147 Cross Highway Redding Ridge, CT 00870 Mr. Joseph Roy, Director of Operations Massachusetts Municipal Wholesale Electric Company Moody Street}}
5000 Dominion Boulevard Glen Allen, VA 23060-6711 Mr. David W. Dodson Licensing Supervisor Dominion Nuclear Connecticut, Inc.
Building 475, 5th Floor Rope Ferry Road Waterford, CT 06385}}

Latest revision as of 18:21, 15 January 2025

Response to Generic Letter 2004-01, Requirements for Steam Generator Tub Inspections
ML051590003
Person / Time
Site: Millstone Dominion icon.png
Issue date: 06/17/2005
From: George Wunder
NRC/NRR/DLPM/LPD1
To: Christian D
Dominion Nuclear Connecticut
Wunder G, NRR/DLPM, 415-1494
References
GL-04-001, TAC MC4830
Download: ML051590003 (3)


Text

June 17, 2005 Mr. David A. Christian Sr. Vice President and Chief Nuclear Officer Dominion Nuclear Connecticut, Inc.

Innsbrook Technical Center 5000 Dominion Boulevard Glen Allen, VA 23060-6711

SUBJECT:

MILLSTONE POWER STATION, UNIT NO. 3 - RESPONSE TO GENERIC LETTER 2004-01, REQUIREMENTS FOR STEAM GENERATOR TUBE INSPECTIONS (TAC NO. MC4830)

Dear Mr. Christian:

On August 30, 2004, the Nuclear Regulatory Commission (NRC) issued Generic Letter (GL) 2004-01, Requirements For Steam Generator Tube Inspections. The purpose of GL 2004-01 was to obtain information that would enable the NRC staff to determine whether licensees steam generator (SG) tube inspection programs comply with the existing tube inspection requirements (the plant technical specifications in conjunction with Appendix B to Title 10 of the Code of Federal Regulations Part 50).

By letter dated October 29, 2004, you responded to GL 2004-01 for Millstone Power Station, Unit No. 3. The staffs review of your response to the GL did not identify any concerns with the inspection practices employed at Millstone Power Station, Unit No. 3. The staff, therefore, concludes that your SG tube inspection practices are in compliance with the existing tube inspection requirements.

Sincerely,

/RA/

George Wunder, Project Manager, Section 2 Project Directorate I Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket No. 50-423 cc: See next page

June 17, 2005 Mr. David A. Christian Sr. Vice President and Chief Nuclear Officer Dominion Nuclear Connecticut, Inc.

Innsbrook Technical Center 5000 Dominion Boulevard Glen Allen, VA 23060-6711

SUBJECT:

MILLSTONE POWER STATION, UNIT NO. 3 - RESPONSE TO GENERIC LETTER 2004-01, REQUIREMENTS FOR STEAM GENERATOR TUBE INSPECTIONS (TAC NO. MC4830)

Dear Mr. Christian:

On August 30, 2004, the Nuclear Regulatory Commission (NRC) issued Generic Letter (GL) 2004-01, Requirements For Steam Generator Tube Inspections. The purpose of GL 2004-01 was to obtain information that would enable the NRC staff to determine whether licensees steam generator (SG) tube inspection programs comply with the existing tube inspection requirements (the plant technical specifications in conjunction with Appendix B to Title 10 of the Code of Federal Regulations Part 50).

By letter dated October 29, 2004, you responded to GL 2004-01 for Millstone Power Station, Unit No. 3 (Millstone 3). The staffs review of your response to the GL did not identify any concerns with the inspection practices employed at Millstone 3. The staff, therefore, concludes that your SG tube inspection practices are in compliance with the existing tube inspection requirements.

Sincerely,

/RA/

George Wunder, Project Manager, Section 2 Project Directorate I Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket No. 50-423 cc: See next page DISTRIBUTION:

PUBLIC OGC PDI-2 R/F ACRS JTerrell JUhle CRaynor CAnderson, RI MBanerjee DRoberts GWunder MYoder PKlein DOCUMENT NAME: ML051590003 OFFICE PDI-2/PM PDI-2/LA PDI-2/SC NAME GWunder CRaynor VNerses for DRoberts DATE 6/16/05 6/15/05 6/17/05 OFFICIAL RECORD COPY

Millstone Power Station, Unit No. 3 cc:

Lillilan M. Cuoco, Esquire Senior Counsel Dominion Resources Services, Inc.

Building 475, 5th Floor Rope Ferry Road Waterford, CT 06385 Edward L. Wilds, Jr., Ph.D.

Director, Division of Radiation Department of Environmental Protection 79 Elm Street Hartford, CT 06106-5127 Regional Administrator, Region I U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 First Selectmen Town of Waterford 15 Rope Ferry Road Waterford, CT 06385 Mr. John Markowicz Co-Chair Nuclear Energy Advisory Council 9 Susan Terrace Waterford, CT 06385 Mr. Evan W. Woollacott Co-Chair Nuclear Energy Advisory Council 128 Terry's Plain Road Simsbury, CT 06070 Senior Resident Inspector Millstone Power Station c/o U.S. Nuclear Regulatory Commission P. O. Box 513 Niantic, CT 06357 Ms. Nancy Burton 147 Cross Highway Redding Ridge, CT 00870 Mr. Joseph Roy, Director of Operations Massachusetts Municipal Wholesale Electric Company Moody Street P.O. Box 426 Ludlow, MA 01056 Mr. J. Alan Price Site Vice President Dominion Nuclear Connecticut, Inc.

Building 475, 5th Floor Rope Ferry Road Waterford, CT 06385 Mr. Chris Funderburk Director, Nuclear Licensing and Operations Support Dominion Resources Services, Inc.

5000 Dominion Boulevard Glen Allen, VA 23060-6711 Mr. David W. Dodson Licensing Supervisor Dominion Nuclear Connecticut, Inc.

Building 475, 5th Floor Rope Ferry Road Waterford, CT 06385