ML060110569: Difference between revisions
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
StriderTol (talk | contribs) (StriderTol Bot change) |
||
| Line 18: | Line 18: | ||
=Text= | =Text= | ||
{{#Wiki_filter:January 11, 2006 | {{#Wiki_filter:January 11, 2006 | ||
Charles D. Naslund, Senior Vice | Charles D. Naslund, Senior Vice | ||
President and Chief Nuclear Officer | President and Chief Nuclear Officer | ||
Union Electric Company | Union Electric Company | ||
P.O. Box 620 | P.O. Box 620 | ||
Fulton, MO 65251 | Fulton, MO 65251 | ||
SUBJECT: ACKNOWLEDGMENT OF RECEIPT OF COMMENTS RELATING TO A | SUBJECT: | ||
ACKNOWLEDGMENT OF RECEIPT OF COMMENTS RELATING TO A | |||
NONCITED VIOLATION AND AN APPARENT VIOLATION IN NRC INSPECTION | |||
REPORT 05000483/2005004 | |||
Dear Mr. Naslund: | Dear Mr. Naslund: | ||
Thank you for the letter from Mr. Young of your staff, dated December 14, 2005, in response to | Thank you for the letter from Mr. Young of your staff, dated December 14, 2005, in response to | ||
our November 5, 2005, letter and integrated NRC Inspection Report 05000483/2005004. In the | our November 5, 2005, letter and integrated NRC Inspection Report 05000483/2005004. In the | ||
December 14, 2005, letter AmerenUE provided clarification to the safety significance analysis of | December 14, 2005, letter AmerenUE provided clarification to the safety significance analysis of | ||
an apparent violation and to the identification of a noncited violation. | an apparent violation and to the identification of a noncited violation. | ||
The NRC is reviewing the comments related to the 2005 third quarter integrated inspection of | The NRC is reviewing the comments related to the 2005 third quarter integrated inspection of | ||
the Callaway Plant and will inform you of the results of our review by separate correspondence. | the Callaway Plant and will inform you of the results of our review by separate correspondence. | ||
In accordance with 10 CFR 2.390 of the NRC's Rules of Practice, a copy of this letter will be | In accordance with 10 CFR 2.390 of the NRC's Rules of Practice, a copy of this letter will be | ||
made available electronically for public inspection in the NRC Public Document Room or from | made available electronically for public inspection in the NRC Public Document Room or from | ||
the Publicly Available Records component of NRCs document system (ADAMS). ADAMS is | the Publicly Available Records component of NRCs document system (ADAMS). ADAMS is | ||
accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public | accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public | ||
Electronic Reading Room). | Electronic Reading Room). | ||
Sincerely, | |||
/RA/ | |||
William B. Jones, Chief | |||
Project Branch B | |||
Division of Reactor Projects | |||
Docket: 50-483 | Docket: 50-483 | ||
License: NPF-30 | License: NPF-30 | ||
Union Electric Company | Union Electric Company | ||
- 2 - | |||
cc: | cc: | ||
Professional Nuclear Consulting, Inc. | Professional Nuclear Consulting, Inc. | ||
19041 Raines Drive | 19041 Raines Drive | ||
Derwood, MD 20855 | Derwood, MD 20855 | ||
John ONeill, Esq. | John ONeill, Esq. | ||
Shaw, Pittman, Potts & Trowbridge | Shaw, Pittman, Potts & Trowbridge | ||
2300 N. Street, N.W. | 2300 N. Street, N.W. | ||
Washington, DC 20037 | Washington, DC 20037 | ||
Mark A. Reidmeyer, Regional | Mark A. Reidmeyer, Regional | ||
Regulatory Affairs Supervisor | |||
Regulatory Affairs | Regulatory Affairs | ||
AmerenUE | AmerenUE | ||
P.O. Box 620 | P.O. Box 620 | ||
Fulton, MO 65251 | Fulton, MO 65251 | ||
Missouri Public Service Commission | Missouri Public Service Commission | ||
Governors Office Building | Governors Office Building | ||
200 Madison Street | 200 Madison Street | ||
P.O. Box 360 | P.O. Box 360 | ||
Jefferson City, MO 65102 | Jefferson City, MO 65102 | ||
H. Floyd Gilzow | H. Floyd Gilzow | ||
Deputy Director for Policy | Deputy Director for Policy | ||
Missouri Department of Natural Resources | Missouri Department of Natural Resources | ||
P. O. Box 176 | P. O. Box 176 | ||
Jefferson City, MO 65102-0176 | Jefferson City, MO 65102-0176 | ||
Rick A. Muench, President and | Rick A. Muench, President and | ||
Chief Executive Officer | |||
Wolf Creek Nuclear Operating Corporation | Wolf Creek Nuclear Operating Corporation | ||
P.O. Box 411 | P.O. Box 411 | ||
Burlington, KS 66839 | Burlington, KS 66839 | ||
Dan I. Bolef, President | Dan I. Bolef, President | ||
Kay Drey, Representative | Kay Drey, Representative | ||
Board of Directors Coalition | Board of Directors Coalition | ||
for the Environment | |||
6267 Delmar Boulevard | 6267 Delmar Boulevard | ||
University City, MO 63130 | University City, MO 63130 | ||
Les H. Kanuckel, Manager | Les H. Kanuckel, Manager | ||
Quality Assurance | Quality Assurance | ||
AmerenUE | AmerenUE | ||
P.O. Box 620 | P.O. Box 620 | ||
Fulton, MO 65251 | Fulton, MO 65251 | ||
Union Electric Company | Union Electric Company | ||
Director, Missouri State Emergency | - 3 - | ||
Director, Missouri State Emergency | |||
Management Agency | |||
P.O. Box 116 | P.O. Box 116 | ||
Jefferson City, MO 65102-0116 | Jefferson City, MO 65102-0116 | ||
Keith D. Young, Manager | Keith D. Young, Manager | ||
Regulatory Affairs | Regulatory Affairs | ||
AmerenUE | AmerenUE | ||
P.O. Box 620 | P.O. Box 620 | ||
Fulton, MO 65251 | Fulton, MO 65251 | ||
David E. Shafer | David E. Shafer | ||
Superintendent, Licensing | Superintendent, Licensing | ||
Regulatory Affairs | Regulatory Affairs | ||
AmerenUE | AmerenUE | ||
P.O. Box 66149, MC 470 | P.O. Box 66149, MC 470 | ||
St. Louis, MO 63166-6149 | St. Louis, MO 63166-6149 | ||
Certrec Corporation | Certrec Corporation | ||
4200 South Hulen, Suite 630 | 4200 South Hulen, Suite 630 | ||
Fort Worth, TX 76109 | Fort Worth, TX 76109 | ||
Keith G. Henke, Planner | Keith G. Henke, Planner | ||
Division of Community and Public Health | Division of Community and Public Health | ||
Office of Emergency Coordination | Office of Emergency Coordination | ||
930 Wildwood, P.O. Box 570 | 930 Wildwood, P.O. Box 570 | ||
Jefferson City, MO 65102 | Jefferson City, MO 65102 | ||
Union Electric Company | Union Electric Company | ||
- 4 - | |||
Electronic distribution by RIV: | Electronic distribution by RIV: | ||
Regional Administrator (BSM1) | Regional Administrator (BSM1) | ||
| Line 124: | Line 128: | ||
Team Leader, DRP/TSS (RLN1) | Team Leader, DRP/TSS (RLN1) | ||
RITS Coordinator (KEG) | RITS Coordinator (KEG) | ||
SUNSI Review Completed: _wbj__ ADAMS: : Yes | SUNSI Review Completed: _wbj__ ADAMS: : Yes | ||
: Publicly Available G Non-Publicly Available G Sensitive | G No Initials: __wbj__ | ||
R:\_REACTORS\_CW\2005\CW2005-04AK-MSP.wpd | : Publicly Available G Non-Publicly Available G Sensitive | ||
: Non-Sensitive | |||
R:\\_REACTORS\\_CW\\2005\\CW2005-04AK-MSP.wpd | |||
RIV:C:DRP/B | |||
WBJones;df | |||
OFFICIAL RECORD COPY | /RA/ | ||
1/11/06 | |||
OFFICIAL RECORD COPY | |||
T=Telephone E=E-mail F=Fax | |||
}} | }} | ||
Latest revision as of 12:23, 15 January 2025
| ML060110569 | |
| Person / Time | |
|---|---|
| Site: | Callaway |
| Issue date: | 01/11/2006 |
| From: | William Jones NRC/RGN-IV/DRP/RPB-B |
| To: | Naslund C Union Electric Co |
| References | |
| IR-05-004 | |
| Download: ML060110569 (4) | |
See also: IR 05000483/2005004
Text
January 11, 2006
Charles D. Naslund, Senior Vice
President and Chief Nuclear Officer
Union Electric Company
P.O. Box 620
Fulton, MO 65251
SUBJECT:
ACKNOWLEDGMENT OF RECEIPT OF COMMENTS RELATING TO A
NONCITED VIOLATION AND AN APPARENT VIOLATION IN NRC INSPECTION
REPORT 05000483/2005004
Dear Mr. Naslund:
Thank you for the letter from Mr. Young of your staff, dated December 14, 2005, in response to
our November 5, 2005, letter and integrated NRC Inspection Report 05000483/2005004. In the
December 14, 2005, letter AmerenUE provided clarification to the safety significance analysis of
an apparent violation and to the identification of a noncited violation.
The NRC is reviewing the comments related to the 2005 third quarter integrated inspection of
the Callaway Plant and will inform you of the results of our review by separate correspondence.
In accordance with 10 CFR 2.390 of the NRC's Rules of Practice, a copy of this letter will be
made available electronically for public inspection in the NRC Public Document Room or from
the Publicly Available Records component of NRCs document system (ADAMS). ADAMS is
accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public
Electronic Reading Room).
Sincerely,
/RA/
William B. Jones, Chief
Project Branch B
Division of Reactor Projects
Docket: 50-483
License: NPF-30
Union Electric Company
- 2 -
cc:
Professional Nuclear Consulting, Inc.
19041 Raines Drive
Derwood, MD 20855
John ONeill, Esq.
Shaw, Pittman, Potts & Trowbridge
2300 N. Street, N.W.
Washington, DC 20037
Mark A. Reidmeyer, Regional
Regulatory Affairs Supervisor
Regulatory Affairs
AmerenUE
P.O. Box 620
Fulton, MO 65251
Missouri Public Service Commission
Governors Office Building
200 Madison Street
P.O. Box 360
Jefferson City, MO 65102
H. Floyd Gilzow
Deputy Director for Policy
Missouri Department of Natural Resources
P. O. Box 176
Jefferson City, MO 65102-0176
Rick A. Muench, President and
Chief Executive Officer
Wolf Creek Nuclear Operating Corporation
P.O. Box 411
Burlington, KS 66839
Dan I. Bolef, President
Kay Drey, Representative
Board of Directors Coalition
for the Environment
6267 Delmar Boulevard
University City, MO 63130
Les H. Kanuckel, Manager
Quality Assurance
AmerenUE
P.O. Box 620
Fulton, MO 65251
Union Electric Company
- 3 -
Director, Missouri State Emergency
Management Agency
P.O. Box 116
Jefferson City, MO 65102-0116
Keith D. Young, Manager
Regulatory Affairs
AmerenUE
P.O. Box 620
Fulton, MO 65251
David E. Shafer
Superintendent, Licensing
Regulatory Affairs
AmerenUE
P.O. Box 66149, MC 470
St. Louis, MO 63166-6149
Certrec Corporation
4200 South Hulen, Suite 630
Fort Worth, TX 76109
Keith G. Henke, Planner
Division of Community and Public Health
Office of Emergency Coordination
930 Wildwood, P.O. Box 570
Jefferson City, MO 65102
Union Electric Company
- 4 -
Electronic distribution by RIV:
Regional Administrator (BSM1)
DRP Director (ATH)
DRS Director (DDC)
DRS Deputy Director (RJC1)
Senior Resident Inspector (MSP)
Branch Chief, DRP/B (WBJ)
Senior Project Engineer, DRP/B (RAK1)
Team Leader, DRP/TSS (RLN1)
RITS Coordinator (KEG)
SUNSI Review Completed: _wbj__ ADAMS: : Yes
G No Initials: __wbj__
- Publicly Available G Non-Publicly Available G Sensitive
- Non-Sensitive
R:\\_REACTORS\\_CW\\2005\\CW2005-04AK-MSP.wpd
RIV:C:DRP/B
WBJones;df
/RA/
1/11/06
OFFICIAL RECORD COPY
T=Telephone E=E-mail F=Fax