ML080290180: Difference between revisions
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
StriderTol (talk | contribs) (StriderTol Bot change) |
||
| Line 18: | Line 18: | ||
=Text= | =Text= | ||
{{#Wiki_filter:From: | {{#Wiki_filter:From: | ||
Siva Lingam To: | |||
njstring@southernco.com Date: | |||
1/28/2008 8:23:02 AM | |||
==Subject:== | ==Subject:== | ||
Re: Vogtle - TS RWST Low Level (GSI 191) | Re: Vogtle - TS RWST Low Level (GSI 191) | ||
==Reference:== | ==Reference:== | ||
| Line 27: | Line 30: | ||
Please provide your response to the following RAI for the referenced license amendment request. | Please provide your response to the following RAI for the referenced license amendment request. | ||
Siva P. Lingam Project Manager (NRR/DORL/LPL2-1) | Siva P. Lingam Project Manager (NRR/DORL/LPL2-1) | ||
Surry and Vogtle Nuclear Stations Location: O8-D5 Mail Stop: O8-G9 Telephone: 301-415-1564 Fax: 301-415-1222 E-mail address: spl@nrc.gov | Surry and Vogtle Nuclear Stations Location: O8-D5 Mail Stop: O8-G9 Telephone: 301-415-1564 Fax: 301-415-1222 E-mail address: spl@nrc.gov | ||
>>> Kulin Desai 1/25/2008 3:11 PM >>> | >>> Kulin Desai 1/25/2008 3:11 PM >>> | ||
: Siva, Please send this RAI to the licensee. | : Siva, Please send this RAI to the licensee. | ||
Demonstrate that there will be adequate net positive suction head (NPSH) available for all ECCS injection pumps operating during a large break LOCA down to the proposed RWST Low Level before switchover to the sump recirculation mode of operation. | Demonstrate that there will be adequate net positive suction head (NPSH) available for all ECCS injection pumps operating during a large break LOCA down to the proposed RWST Low Level before switchover to the sump recirculation mode of operation. | ||
Thanks Kulin CC: | Thanks Kulin CC: | ||
Kulin Desai; Melanie Wong Mail Envelope Properties (479DD736.DC4 : 13 : 35786) | |||
==Subject:== | ==Subject:== | ||
Re: Vogtle - TS RWST Low Level (GSI 191) | Re: Vogtle - TS RWST Low Level (GSI 191) | ||
Creation Date | Creation Date 1/28/2008 8:23:02 AM From: | ||
Siva Lingam Created By: | |||
SPL@nrc.gov Recipients Action Date & Time nrc.gov EBGWPO01.HQGWDO01 Delivered 1/28/2008 8:23:05 AM MCW CC (Melanie Wong) | |||
Opened 1/28/2008 8:54:58 AM nrc.gov OWGWPO03.HQGWDO01 Delivered 1/28/2008 8:23:05 AM KDD CC (Kulin Desai) | |||
Opened 1/28/2008 9:10:47 AM | |||
southernco.com | southernco.com Transferred 1/28/2008 8:23:19 AM njstring (njstring@southernco.com) | ||
Post Office | Post Office Delivered Route EBGWPO01.HQGWDO01 1/28/2008 8:23:05 AM nrc.gov OWGWPO03.HQGWDO01 1/28/2008 8:23:05 AM nrc.gov southernco.com Files Size Date & Time MESSAGE 1830 1/28/2008 8:23:02 AM Options Auto Delete: | ||
No Expiration Date: | |||
None Notify Recipients: | |||
Yes Priority: | |||
Standard ReplyRequested: | |||
No Return Notification: | |||
None Concealed | |||
==Subject:== | ==Subject:== | ||
No Security: | No Security: | ||
Standard To Be Delivered: | |||
Immediate Status Tracking: | |||
Delivered & Opened}} | |||
Latest revision as of 18:29, 14 January 2025
| ML080290180 | |
| Person / Time | |
|---|---|
| Site: | Vogtle |
| Issue date: | 01/28/2008 |
| From: | Siva Lingam NRC/NRR/ADRO/DORL/LPLII-1 |
| To: | Stringfellow N Southern Nuclear Operating Co |
| Lingam, Siva NRR/DORL 415-1564 | |
| References | |
| NL-07-2168, TAC MD7772, TAC MD7773 | |
| Download: ML080290180 (2) | |
Text
From:
Siva Lingam To:
njstring@southernco.com Date:
1/28/2008 8:23:02 AM
Subject:
Re: Vogtle - TS RWST Low Level (GSI 191)
Reference:
LAR to revise TSs 3.3.2 and 3.5.4, SNC Letter NL-07-2168 dated January 9, 2008 (TAC Nos. MD7772 and MD7773)
Please provide your response to the following RAI for the referenced license amendment request.
Siva P. Lingam Project Manager (NRR/DORL/LPL2-1)
Surry and Vogtle Nuclear Stations Location: O8-D5 Mail Stop: O8-G9 Telephone: 301-415-1564 Fax: 301-415-1222 E-mail address: spl@nrc.gov
>>> Kulin Desai 1/25/2008 3:11 PM >>>
- Siva, Please send this RAI to the licensee.
Demonstrate that there will be adequate net positive suction head (NPSH) available for all ECCS injection pumps operating during a large break LOCA down to the proposed RWST Low Level before switchover to the sump recirculation mode of operation.
Thanks Kulin CC:
Kulin Desai; Melanie Wong Mail Envelope Properties (479DD736.DC4 : 13 : 35786)
Subject:
Re: Vogtle - TS RWST Low Level (GSI 191)
Creation Date 1/28/2008 8:23:02 AM From:
Siva Lingam Created By:
SPL@nrc.gov Recipients Action Date & Time nrc.gov EBGWPO01.HQGWDO01 Delivered 1/28/2008 8:23:05 AM MCW CC (Melanie Wong)
Opened 1/28/2008 8:54:58 AM nrc.gov OWGWPO03.HQGWDO01 Delivered 1/28/2008 8:23:05 AM KDD CC (Kulin Desai)
Opened 1/28/2008 9:10:47 AM
southernco.com Transferred 1/28/2008 8:23:19 AM njstring (njstring@southernco.com)
Post Office Delivered Route EBGWPO01.HQGWDO01 1/28/2008 8:23:05 AM nrc.gov OWGWPO03.HQGWDO01 1/28/2008 8:23:05 AM nrc.gov southernco.com Files Size Date & Time MESSAGE 1830 1/28/2008 8:23:02 AM Options Auto Delete:
No Expiration Date:
None Notify Recipients:
Yes Priority:
Standard ReplyRequested:
No Return Notification:
None Concealed
Subject:
No Security:
Standard To Be Delivered:
Immediate Status Tracking:
Delivered & Opened