{{#Wiki_filter:SLs 2.0 2.0 SAFETY LIMITS (SLs) 2.1 SLs 2.1.1 Reactor Core SLs 2.1.1.1 With the reactor steam dome pressure < 785 psig or core flow < 10% rated core flow:
{{#Wiki_filter:SLs 2.0 Quad Cities 1 and 2 2.0-1 Amendment No.
THERMAL POWER shall be 25% RTP.
2.0 SAFETY LIMITS (SLs) 2.1 SLs 2.1.1 Reactor Core SLs 2.1.1.1 With the reactor steam dome pressure < 785 psig or core flow < 10% rated core flow:
2.1.1.2 With the reactor steam dome pressure 785 psig and core flow 10% rated core flow:
THERMAL POWER shall be 25% RTP.
For two recirculation loop operation, MCPR shall be 1.11, or for single recirculation loop operation, MCPR shall be 1.13.
2.1.1.2 With the reactor steam dome pressure 785 psig and core flow 10% rated core flow:
2.1.1.3 Reactor vessel water level shall be greater than the top of active irradiated fuel.
For two recirculation loop operation, MCPR shall be 1.11, or for single recirculation loop operation, MCPR shall be 1.13.
2.1.2 Reactor Coolant System Pressure SL Reactor steam dome pressure shall be 1345 psig.
2.1.1.3 Reactor vessel water level shall be greater than the top of active irradiated fuel.
2.2 SL Violations With any SL violation, the following actions shall be completed within 2 hours:
2.1.2 Reactor Coolant System Pressure SL Reactor steam dome pressure shall be 1345 psig.
2.2.1 Restore compliance with all SLs; and 2.2.2 Insert all insertable control rods.
2.2 SL Violations With any SL violation, the following actions shall be completed within 2 hours:
Quad Cities 1 and 2                  2.0-1              Amendment No.}}
2.2.1 Restore compliance with all SLs; and 2.2.2 Insert all insertable control rods.}}

Latest revision as of 18:27, 14 January 2025

Technical Specifications, Issuance of Amendments Safety Limit Minimum Critical Power Ratio
ML080310073
Person / Time
Site: Quad Cities  Constellation icon.png
Issue date: 02/28/2008
From:
NRC/NRR/ADRO/DORL/LPLIII-2
To:
Wiebe, J
Shared Package
ML080280231 List:
References
TAC MD7374, TAC MD7375
Download: ML080310073 (1)


Text

SLs 2.0 Quad Cities 1 and 2 2.0-1 Amendment No.

2.0 SAFETY LIMITS (SLs) 2.1 SLs 2.1.1 Reactor Core SLs 2.1.1.1 With the reactor steam dome pressure < 785 psig or core flow < 10% rated core flow:

THERMAL POWER shall be 25% RTP.

2.1.1.2 With the reactor steam dome pressure 785 psig and core flow 10% rated core flow:

For two recirculation loop operation, MCPR shall be 1.11, or for single recirculation loop operation, MCPR shall be 1.13.

2.1.1.3 Reactor vessel water level shall be greater than the top of active irradiated fuel.

2.1.2 Reactor Coolant System Pressure SL Reactor steam dome pressure shall be 1345 psig.

2.2 SL Violations With any SL violation, the following actions shall be completed within 2 hour2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />s:

2.2.1 Restore compliance with all SLs; and 2.2.2 Insert all insertable control rods.