{{#Wiki_filter:Westinghouse Non-Proprietary Class 3
{{#Wiki_filter:*** This record was final approved on 6/27/2022, 9:06:17 AM. (This statement was added by the PRIME system upon its validation)
 
Westinghouse Non-Proprietary Class 3 Westinghouse Electric Company 1000 Westinghouse Drive Cranberry Township, Pennsylvania 16066 USA U.S. Nuclear Regulatory Commission Document Control Desk 11555 Rockville Pike Rockville, MD 20852 Direct tel: +33645064131 e-mail: merciee@westinghouse.com LTR-NRC-22-25 June 27th, 2022
Westinghouse Electric Company 1000 Westinghouse Drive Cranberry Township, Pennsylvania 16066 USA
 
U.S. Nuclear Regulatory Commission Direct tel: +33645064131 Document Control Desk e-mail: merciee@westinghouse.com 11555 Rockville Pike Rockville, MD 20852 LTR - NRC - 2 2 - 25
 
June 2 7th, 202 2


==Subject:==
==Subject:==
Request for Withdrawal from Review for Amendment 5 to CoC 72-1026 (SENTRY' Dry Fuel Storage System)
Request for Withdrawal from Review for Amendment 5 to CoC 72-1026 (SENTRY' Dry Fuel Storage System)  


==References:==
==References:==
: 1. Westinghouse Letter LTR - NRC 35, Transmittal of Amendment Request for CoC 72-1026), April 30, 2020 (ML 20121A214)
: 1. Westinghouse Letter LTR-NRC-20-35, Transmittal of Amendment Request for CoC 72-1026), April 30, 2020 (ML20121A214)
: 2. APPLICATION FOR THE WESTING HOUSE SENTRY' DRY STORAGE CASK SYSTEM, CERTIFICATE OF COMPLIANCE NO. 1026, AMENDMENT NO. 5 -
: 2. APPLICATION FOR THE WESTINGHOUSE SENTRY' DRY STORAGE CASK SYSTEM, CERTIFICATE OF COMPLIANCE NO. 1026, AMENDMENT NO. 5 -
ACCEPTED FOR REVIEW (EPID L-2020-LLA -0105), December 21st, 2020 (ML21154A156)
ACCEPTED FOR REVIEW (EPID L-2020-LLA-0105), December 21st, 2020 (ML21154A156)
 
Amendment 5 to Certificate of Conformance (CoC) 72-1026 was submitted by Westinghouse via Reference 1 for review. The NRC issued their acceptance for review in Reference 2.
Amendment 5 to Certificate of Conformance (CoC) 72-1026 was submitted by Westinghouse via Reference 1 for review. The NRC issued their acceptance for review in Reference 2.
Due to ongoing refinements in the spent fuel storage portfolio, Westinghouse wishes to withdraw this Amendment submittal from further NRC review and requests that no further review activities be undertaken by the NRC.
Due to ongoing refinements in the spent fuel storage portfolio, Westinghouse wishes to withdraw this Amendment submittal from further NRC review and requests that no further review activities be undertaken by the NRC.
Correspondence with respect to this letter should be addressed to: Emmanuel Mercier, 1000 Westinghouse Drive, Cranberry Township, PA, 16066 Emmanuel Mercier, Manager Product Manager, Decommissioning & Dismantling


Correspondence with respect to this letter should be addressed to: Emmanuel Mercier, 1000 Westinghouse D rive, Cranberry Township, PA, 16066
*** This record was final approved on 6/27/2022, 9:06:17 AM. (This statement was added by the PRIME system upon its validation)
 
Westinghouse Non-Proprietary Class 3 Westinghouse Electric Company 1000 Westinghouse Drive Cranberry Township, Pennsylvania 16066 USA bcc: Michael M. Corletti Dewey C. Olinski Matija Zajec Donald (Wayne) Lewis Zachary S Harper Jennifer E. Meneely Adam D. Malinowski Approved by: Emmanuel Mercier, Product Manager
Emmanuel Mercier, Manager Product Manager, Decommissioning & Dismantling
* Decommissioning and Dismantling  
 
*** This record was final approved on 6/27/2022, 9:06:17 AM. (This statement was added by the PRIME system upon its validation)
Westinghouse Non-Proprietary Class 3
 
Westinghouse Electric Company 1000 Westinghouse Drive Cranberry Township, Pennsylvania 16066 USA
 
bcc: Michael M. Corletti Dewey C. Olinski Matija Zajec Donald (Wayne) Lewis Zachary S Harper Jennifer E. Meneely Adam D. Malinowski
 
Approved by: Emmanuel Mercier, Product Manager
* Decommissioning and Dismantling


*** This record was final approved on 6/27/2022, 9:06:17 AM. (This statement was added by the PRIME system upon its validation)
*** This record was final approved on 6/27/2022, 9:06:17 AM. (This statement was added by the PRIME system upon its validation)
LTR-NRC-22-25 Revision 0 Non-Proprietary Class 3
LTR-NRC-22-25 Revision 0 Non-Proprietary Class 3
 
**This page was added to the quality record by the PRIME system upon its validation and shall not be considered in the page numbering of this document.**
**This page was added to the quality record by the PRIME system upon its validation and shall not be considered in the page numbering of this document.**
Approval Information Manager Approval Mercier Emmanuel Jun-27-2022 09:06:17 Files approved on Jun-27-2022}}
Approval Information
 
Manager Approval Mercier Emmanuel Jun-27-2022 09:06:17
 
Files approved on Jun-27-2022
 
*** This record was final approved on 6/27/2022, 9:06:17 AM. (This statement was added by the PRIME system upon its validation)}}

Latest revision as of 16:38, 27 November 2024

Westinghouse Electric Company - Request for Withdrawal from Review for Amendment 5 to CoC 72-1026 (Sentry Dry Fuel Storage System)
ML22178A067
Person / Time
Site: 07201026
Issue date: 06/27/2022
From: Mercier E
Westinghouse
To:
Document Control Desk, Office of Nuclear Material Safety and Safeguards
References
LTR-NRC-22-25
Download: ML22178A067 (3)


Text

      • This record was final approved on 6/27/2022, 9:06:17 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 Westinghouse Electric Company 1000 Westinghouse Drive Cranberry Township, Pennsylvania 16066 USA U.S. Nuclear Regulatory Commission Document Control Desk 11555 Rockville Pike Rockville, MD 20852 Direct tel: +33645064131 e-mail: merciee@westinghouse.com LTR-NRC-22-25 June 27th, 2022

Subject:

Request for Withdrawal from Review for Amendment 5 to CoC 72-1026 (SENTRY' Dry Fuel Storage System)

References:

1. Westinghouse Letter LTR-NRC-20-35, Transmittal of Amendment Request for CoC 72-1026), April 30, 2020 (ML20121A214)
2. APPLICATION FOR THE WESTINGHOUSE SENTRY' DRY STORAGE CASK SYSTEM, CERTIFICATE OF COMPLIANCE NO. 1026, AMENDMENT NO. 5 -

ACCEPTED FOR REVIEW (EPID L-2020-LLA-0105), December 21st, 2020 (ML21154A156)

Amendment 5 to Certificate of Conformance (CoC) 72-1026 was submitted by Westinghouse via Reference 1 for review. The NRC issued their acceptance for review in Reference 2.

Due to ongoing refinements in the spent fuel storage portfolio, Westinghouse wishes to withdraw this Amendment submittal from further NRC review and requests that no further review activities be undertaken by the NRC.

Correspondence with respect to this letter should be addressed to: Emmanuel Mercier, 1000 Westinghouse Drive, Cranberry Township, PA, 16066 Emmanuel Mercier, Manager Product Manager, Decommissioning & Dismantling

      • This record was final approved on 6/27/2022, 9:06:17 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 Westinghouse Electric Company 1000 Westinghouse Drive Cranberry Township, Pennsylvania 16066 USA bcc: Michael M. Corletti Dewey C. Olinski Matija Zajec Donald (Wayne) Lewis Zachary S Harper Jennifer E. Meneely Adam D. Malinowski Approved by: Emmanuel Mercier, Product Manager

  • Decommissioning and Dismantling
      • This record was final approved on 6/27/2022, 9:06:17 AM. (This statement was added by the PRIME system upon its validation)

LTR-NRC-22-25 Revision 0 Non-Proprietary Class 3

    • This page was added to the quality record by the PRIME system upon its validation and shall not be considered in the page numbering of this document.**

Approval Information Manager Approval Mercier Emmanuel Jun-27-2022 09:06:17 Files approved on Jun-27-2022