IR 05000413/2022010: Difference between revisions
StriderTol (talk | contribs) (StriderTol Bot change) |
StriderTol (talk | contribs) (StriderTol Bot change) |
||
| Line 36: | Line 36: | ||
==Inspection Report== | ==Inspection Report== | ||
Docket Numbers: 05000413 and 05000414 | Docket Numbers: | ||
05000413 and 05000414 | |||
License Numbers: NPF-35 and NPF-52 | License Numbers: | ||
NPF-35 and NPF-52 | |||
Report Numbers: 05000413/2022010 and 05000414/2022010 | Report Numbers: | ||
05000413/2022010 and 05000414/2022010 | |||
Enterprise Identifier: I-2022-010-0038 | Enterprise Identifier: I-2022-010-0038 | ||
Licensee: | |||
Licensee: Duke Energy Carolinas, LLC | Duke Energy Carolinas, LLC | ||
Facility: | |||
Facility: Catawba Nuclear Station | Catawba Nuclear Station | ||
Location: | |||
Location: York, SC | York, SC | ||
Inspection Dates: | |||
Inspection Dates: May 23, 2022, to June 10, 2022 | May 23, 2022, to June 10, 2022 | ||
Inspectors: | |||
Inspectors: R. Fanner, Reactor Inspector N. Morgan, Intergovernmental Liaison Project Manager G. Ottenberg, Senior Reactor Inspector J. Zudans, Contractor | R. Fanner, Reactor Inspector | ||
N. Morgan, Intergovernmental Liaison Project Manager | |||
Approved By: James B. Baptist, Chief Engineering Branch 1 Division of Reactor Safety | G. Ottenberg, Senior Reactor Inspector | ||
J. Zudans, Contractor | |||
Approved By: | |||
James B. Baptist, Chief | |||
Engineering Branch 1 | |||
Division of Reactor Safety | |||
Enclosure | Enclosure | ||
| Line 75: | Line 79: | ||
{{IP sample|IP=IP 71111.21|count=8}} | {{IP sample|IP=IP 71111.21|count=8}} | ||
The inspectors: | The inspectors: | ||
a. Evaluated whether the sampled POVs are being tested and maintained in accordance with NRC regulations along with the licensees commitments and/or licensing bases. | a. Evaluated whether the sampled POVs are being tested and maintained in accordance with NRC regulations along with the licensees commitments and/or licensing bases. | ||
| Line 83: | Line 86: | ||
d. Evaluated maintenance activities including a walkdown of the sampled POVs (if accessible). | d. Evaluated maintenance activities including a walkdown of the sampled POVs (if accessible). | ||
(1)1KC050A, Auxiliary Building Non-Essential Header Isolation (2)1ND027, 1A Residual Heat Removal (ND) Heat Exchanger Bypass Control (3)2CA050A, Auxiliary Feedwater (CA) Pump 2 Discharge to Steam Generator 2C Isolation (4)1NV010A, Letdown Orifice 1B Outlet Containment Isolation (5)2CA056, CA Pump 2A Flow to Steam Generator 2B (6)2NC035B, Pressurizer Power Operated Relief Valve Isolation (7)2NI173A, ND Header 2A to Cold Legs C & D (8)1CF033, 1A Steam Generator Feedwater Containment Isolation | |||
==INSPECTION RESULTS== | ==INSPECTION RESULTS== | ||
| Line 102: | Line 99: | ||
=DOCUMENTS REVIEWED= | =DOCUMENTS REVIEWED= | ||
Inspection Type Designation Description or Title Revision or | Inspection | ||
Procedure | |||
71111.21N.02 Calculations AD-EG-ALL-1117 U2, 6.9KV, 4.16KV, & 600V Auxiliary Power Systems | Type | ||
Designation | |||
Description or Title | |||
Revision or | |||
Date | |||
71111.21N.02 | |||
Calculations | |||
AD-EG-ALL-1117 | |||
U2, 6.9KV, 4.16KV, & 600V Auxiliary Power Systems | |||
Safety-Related Voltage Analysis | Safety-Related Voltage Analysis | ||
CNC -1205.19-00- Generic Letter 89-10 MOV Calculations, NC System; 1(2) | CNC -1205.19-00- | ||
28 NC033A, 035B, 1NC031B | Generic Letter 89-10 MOV Calculations, NC System; 1(2) | ||
CNC -1205.19-00- 89-10 Calculation for 1&2 CA038A, 42B, 46B, 50A, 54B, | 28 | ||
29 58A, 62A, 66B | NC033A, 035B, 1NC031B | ||
CNC -1205.19-00- Generic Letter 89-10 Calculation For Valves 1 and | CNC -1205.19-00- | ||
0033 NI173A and NI178B | 89-10 Calculation for 1&2 CA038A, 42B, 46B, 50A, 54B, | ||
CNC -1205.19-00- GL 89-10 Set-Up Calculation for Valves 1KC001A, | 29 | ||
0110 1KC002B, 1KC050A, 1KC053B, 2KC001A, AND | 58A, 62A, 66B | ||
CNC -1205.19-00- | |||
Generic Letter 89-10 Calculation For Valves 1 and | |||
0033 | |||
NI173A and NI178B | |||
CNC -1205.19-00- | |||
GL 89-10 Set-Up Calculation for Valves 1KC001A, | |||
0110 | |||
1KC002B, 1KC050A, 1KC053B, 2KC001A, AND | |||
2KC002B | 2KC002B | ||
CNC -1205.19-00- Required Thrust Calculation for 1(2)NC31B, 33A, 35B 000 | CNC -1205.19-00- | ||
0195 (AD/DD PPM); Item NO. 09J-363 & 364 | Required Thrust Calculation for 1(2)NC31B, 33A, 35B | ||
CNC -1205.41-00- | 000 | ||
27 Capability Calculations | 0195 | ||
CNC -1206.02-80- KCC - Component Cooling Heat Exchangers 1 A & 1 B to 018 | (AD/DD PPM); Item NO. 09J-363 & 364 | ||
2019 the RHR Heat Exchangers 1A & 1 B. Also to the Inlet of | CNC -1205.41-00- | ||
(2) ND 26, 27, 60, and 61 Fisher Actuator and Margin | |||
27 | |||
Capability Calculations | |||
CNC -1206.02-80- | |||
KCC - Component Cooling Heat Exchangers 1 A & 1 B to | |||
018 | |||
2019 | |||
the RHR Heat Exchangers 1A & 1 B. Also to the Inlet of | |||
the Letdown & Fuel Pool Heat Exchangers | the Letdown & Fuel Pool Heat Exchangers | ||
CNC -1223.11-00- Limiting 1ST Stroke Time for ND26, ND27, ND60 and 000 | CNC -1223.11-00- | ||
0055 ND6V | Limiting 1ST Stroke Time for ND26, ND27, ND60 and | ||
CNC -1381.05-00- U2, 6.9KV, 4.16KV, & 600V AUXILIARY POWER | 000 | ||
0199 SYSTEMS SAFETY-RELATED VOLTAGE ANALYSIS | 0055 | ||
CNC 1205.41-00- | ND6V | ||
0018 Evaluation supporting Air Operated Valve (AOV) Program | CNC -1381.05-00- | ||
CNC-1205.41-00- Air Operated Valve (AOV) Program Scope Calculation | U2, 6.9KV, 4.16KV, & 600V AUXILIARY POWER | ||
0199 | |||
SYSTEMS SAFETY-RELATED VOLTAGE ANALYSIS | |||
CNC 1205.41-00- | |||
(2) NV 010A, 011A, and 013A Required Thrust | |||
0018 | |||
Evaluation supporting Air Operated Valve (AOV) Program | |||
CNC-1205.41-00- | |||
Air Operated Valve (AOV) Program Scope Calculation | |||
0001 | 0001 | ||
CNC-1205.41-00- FEEDWATER ISOLATION VALVES, 1(2)CF33, 42, 51, 05/03/2022 | CNC-1205.41-00- | ||
0005 AND | FEEDWATER ISOLATION VALVES, 1(2)CF33, 42, 51, | ||
05/03/2022 | |||
0005 | |||
AND | |||
60, DESIGN BASIS SIZING CALCULATION | 60, DESIGN BASIS SIZING CALCULATION | ||
CNC-1205.41-00- Catawba Air-operated Valve (AOV) Risk Ranking | CNC-1205.41-00- | ||
0016 Calculation | Catawba Air-operated Valve (AOV) Risk Ranking | ||
CNC-1205.41-00- | 0016 | ||
Inspection Type Designation Description or Title Revision or | Calculation | ||
CNC-1205.41-00- | |||
0018 Evaluation supporting Air Operated Valve (AOV) Program | (2) NV 010A, 011A, and 013A Required Thrust | ||
CNC-1205.41-00- 1(2) CA-040, 044, 056, 060 and 1(2) CA-036, 048, 052, | |||
22 064 Actuator Capability Evaluation Supporting Air | Inspection | ||
Procedure | |||
Type | |||
Designation | |||
Description or Title | |||
Revision or | |||
Date | |||
0018 | |||
Evaluation supporting Air Operated Valve (AOV) Program | |||
CNC-1205.41-00- | |||
1(2) CA-040, 044, 056, 060 and 1(2) CA-036, 048, 052, | |||
22 | |||
064 Actuator Capability Evaluation Supporting Air | |||
Operated (AOV) Program | Operated (AOV) Program | ||
CNC-1206.03-00- Doghouse Environmental Temperature Due to Main Rev. 3 | CNC-1206.03-00- | ||
0181 Steam Line Break | Doghouse Environmental Temperature Due to Main | ||
CNC-1223.02-00- Inservice Testing (IST) Valve Response Measurement 04/08/2011 | Rev. 3 | ||
23 Uncertainty | 0181 | ||
CNC-1223.12-00- Design Parameters for ND Header to Cold Leg | Steam Line Break | ||
0045 Containment Isolation Valves 1 & 2 NI173A, NI178B | CNC-1223.02-00- | ||
CNC-1552.08-00- Long-Term Containment Response - Manual NS Initiation | Inservice Testing (IST) Valve Response Measurement | ||
04/08/2011 | |||
23 | |||
Uncertainty | |||
CNC-1223.12-00- | |||
Design Parameters for ND Header to Cold Leg | |||
0045 | |||
Containment Isolation Valves 1 & 2 NI173A, NI178B | |||
CNC-1552.08-00- | |||
Long-Term Containment Response - Manual NS Initiation | |||
0390 | 0390 | ||
CNM 1205.00- Design/Seismic Report (Weak Link) for 09J-2056, 2", | CNM 1205.00- | ||
2182.001 1500#, SS, Gate Valve | Design/Seismic Report (Weak Link) for 09J-2056, 2", | ||
CNM 1205.01-Design & Seismic RPT 6J-339 C | 2182.001 | ||
1500#, SS, Gate Valve | |||
CNM 1205.01- | |||
Design & Seismic RPT 6J-339 | |||
C | |||
0797.001 | 0797.001 | ||
Corrective Action ARs | Corrective Action | ||
Documents 01497427, 02428219, 01898027, 02300922 | ARs | ||
Corrective Action NCR 02318266 OP-CN-CF-CF lesson plan does not identify the safety 06/24/2022 | 2373087, 02294259, 01497427, 02407695, 02294259, | ||
Documents related power supply for Feedwater Isolation Valve's | Documents | ||
Resulting from NCR 02429804 | 01497427, 02428219, 01898027, 02300922 | ||
Inspection NCR 02430135 | Corrective Action | ||
NCR 02318266 | |||
OP-CN-CF-CF lesson plan does not identify the safety | |||
06/24/2022 | |||
Documents | |||
related power supply for Feedwater Isolation Valve's | |||
Resulting from | |||
NCR 02429804 | |||
22 NRC DBAI POV - 2NI173A Motor Brake Internals | |||
06/02/2022 | |||
Inspection | |||
NCR 02430135 | |||
22 NRC DBAI POV - 1KC-50A Maximum Transmitted | |||
06/06/2022 | |||
Torque | Torque | ||
NCR 02430281 | NCR 02430281 | ||
22 NRC DBAI POV - Lesson Plans not revised post | |||
06/07/2022 | |||
Mod | Mod | ||
NCR 02430301 PT/1/A/4350/002 E enclosure 13.16 could not be | NCR 02430301 | ||
NCR 02430342 | PT/1/A/4350/002 E enclosure 13.16 could not be located | ||
06/07/2022 | |||
NCR 02430342 | |||
22 NRC POV DBAI - Incorrect Reference in Flowserve | |||
06/07/2022 | |||
Letter | Letter | ||
NCR 02430464 Obstructions on 522' elevation floor drains 06/08/2022 | NCR 02430464 | ||
NCR 02430567 NRC DBAI POV-EOPs do not align with UFSAR 06/09/2022 | Obstructions on 522' elevation floor drains | ||
NCR 02430713 | 06/08/2022 | ||
NCR 02430567 | |||
NRC DBAI POV-EOPs do not align with UFSAR | |||
06/09/2022 | |||
NCR 02430713 | |||
22 NRC DBAI POV - 2NC35B - Actuator Fastener Bolt | |||
06/09/2022 | |||
Preload | Preload | ||
NCR 02431086 | NCR 02431086 | ||
22 NRC DBAI POV - UFSAR sec.6.2.4.1 incorrect | |||
06/14/2022 | |||
statement | statement | ||
Inspection Type Designation Description or Title Revision or | Inspection | ||
Procedure | |||
NCR 2428952 | Type | ||
Designation | |||
Description or Title | |||
Revision or | |||
Date | |||
NCR 2428952 | |||
22 NRC DBAI POV - 2NC035B High Temp Torque | |||
Factor | Factor | ||
NCR 2430567 NRC DBAI POV-EOPs do not align with UFSAR 06/09/2022 | 05/26/2022 | ||
NCR 2430567 | |||
40846-08 20- Class 150 Valve Assembly and Limitorque H2BC- | NRC DBAI POV-EOPs do not align with UFSAR | ||
06/09/2022 | |||
2-403-0012-3 | |||
Limitorque Valve Control | |||
DI | |||
40846-08 | |||
20- Class 150 Valve Assembly and Limitorque H2BC- | |||
SMB-00-10 | SMB-00-10 | ||
CN -1561-01.00 Flow Diagram of Residual Heat Removal System (ND) | DE | ||
CN -2561-01.00 Flow Diagram of Residual Heat Removal System (ND) | CN -1561-01.00 | ||
CN -2562-01.01 Flow Diagram, Safety Injection System (NI) | Flow Diagram of Residual Heat Removal System (ND) | ||
CN -2592-01.01 Flow Diagram Auxiliary Feedwater System (CA) | CN -2561-01.00 | ||
CN-1573-01.0 Flow Diagram of Component Cooling System (KC) | Flow Diagram of Residual Heat Removal System (ND) | ||
CN-2499-CA.07-Instrument Detail Motor Driven Auxiliary Feedwater Pump | CN -2562-01.01 | ||
Flow Diagram, Safety Injection System (NI) | |||
CN -2592-01.01 | |||
Flow Diagram Auxiliary Feedwater System (CA) | |||
CN-1573-01.0 | |||
Flow Diagram of Component Cooling System (KC) | |||
CN-2499-CA.07- | |||
Instrument Detail Motor Driven Auxiliary Feedwater Pump | |||
to Steam Generator Flow Control | to Steam Generator Flow Control | ||
CN-2553-01.01 Flow Diagram of Reactor Coolant System (NC) | CN-2553-01.01 | ||
CN-2562-01.03 Flow Diagram of Safety Injection System (NI) | Flow Diagram of Reactor Coolant System (NC) | ||
CNEE-0247-04.12 Auxiliary Feedwater System (CA) CA Pump No. 2 Disch | CN-2562-01.03 | ||
Flow Diagram of Safety Injection System (NI) | |||
CNEE-0247-04.12 | |||
Auxiliary Feedwater System (CA) CA Pump No. 2 Disch | |||
to S/D 2C Isol. Vlv. 2CA050A | to S/D 2C Isol. Vlv. 2CA050A | ||
CNEE-0247-Auxiliary Feedwater System (CA) CA Pump No. 2 Disch | CNEE-0247- | ||
04.12-01 | |||
CNEE-0250-01.09 Reactor Coolant System (NC) Pzr Power Operated Relief | Auxiliary Feedwater System (CA) CA Pump No. 2 Disch | ||
to S/D 2C Isol. Vlv. 2CA050A Controls | |||
CNEE-0250-01.09 | |||
Reactor Coolant System (NC) Pzr Power Operated Relief | |||
Isolation Valve 2NC035B | Isolation Valve 2NC035B | ||
CNEE-0251-01.32 Elementary Diagram Safety Injection System (NI) ND | CNEE-0251-01.32 | ||
Elementary Diagram Safety Injection System (NI) ND | |||
HDR to NC Cold Legs C and D Isolation Valve 2NI173A | HDR to NC Cold Legs C and D Isolation Valve 2NI173A | ||
CNM 1205.00- | CNM 1205.00- | ||
0074.001 | 0074.001 | ||
CNM 1205.00- | 8"SS Motor Oper Gate Vlv Item 9J211 | ||
CNM 1205.00- | |||
2181.001 | 2181.001 | ||
CNM 1205.01- | O/L Drawing for 09J-2056, 2", 1500#, SS, Gate Valve | ||
CNM 1205.01- | |||
0790.001 | 0790.001 | ||
4" 1500LB CS EMO DP Gate Valve 6J-339 | |||
H | |||
CNM 1205.01- | |||
0790.002 | 0790.002 | ||
CNM 1205.06-O/L, C/S, B/M, OPR, W/D Control Valves 1&2/CA/40, 44, | 4" 1500LB CS DP Gate Valve 6J-339 | ||
J | |||
W9223811, Sht. 1 3"- 1530 Weld Ends Stainless Steel Double Disc Gate B | CNM 1205.06- | ||
Inspection Type Designation Description or Title Revision or | 20.001 | ||
O/L, C/S, B/M, OPR, W/D Control Valves 1&2/CA/40, 44, | |||
& 60 | |||
J | |||
Drawings | |||
W9223811, Sht. 1 | |||
3"- 1530 Weld Ends Stainless Steel Double Disc Gate | |||
B | |||
Inspection | |||
Procedure | |||
Type | |||
Designation | |||
Description or Title | |||
Revision or | |||
Date | |||
Valve for SMB-00-15 Limitorque Actuator | Valve for SMB-00-15 Limitorque Actuator | ||
W9223811, Sht. 2 3"- 1530 Weld Ends Stainless Steel Double Disc Gate | W9223811, Sht. 2 | ||
3"- 1530 Weld Ends Stainless Steel Double Disc Gate | |||
Valve for SMB-00-15 Limitorque Actuator | Valve for SMB-00-15 Limitorque Actuator | ||
B | |||
CN 20328 | |||
Modify control circuit wiring on 2NI-9A, 10B, 100B, 183B, | |||
2A, 173A, 178B, 184B, 185A, 2NV-89A, 91B, 188A, | |||
189B, 252A, 253B, 312A, and 314B to provide "limit | 189B, 252A, 253B, 312A, and 314B to provide "limit | ||
actuated" torque switch bypass contacts which can be | actuated" torque switch bypass contacts which can be | ||
adjusted independent of Indication or interlocks. | adjusted independent of Indication or interlocks. | ||
CN 21319 Modify CA Control Valves to Prevent S/G Overfill During | 11/07/1988 | ||
CN 21319 | |||
Modify CA Control Valves to Prevent S/G Overfill During | |||
SGTR | SGTR | ||
EC 0000106724 Revise MOV Set-Up Sheets to Meet GL 96-05 | 08/11/1999 | ||
EC 0000106724 | |||
Revise MOV Set-Up Sheets to Meet GL 96-05 | |||
Requirements for 1KC001A, 002B, 050A | Requirements for 1KC001A, 002B, 050A | ||
EC 0000402775 U-1 AND U-2 NW System Isolation to Specific CIVs | 09/07/2012 | ||
Engineering | |||
Changes | |||
CNC -1205.19-00- Kalsi Engineering Report 2919C, GL96-05 Periodic | EC 0000402775 | ||
U-1 AND U-2 NW System Isolation to Specific CIVs | |||
CNC -1205.19-00- | |||
0176-ICC-0003 | |||
EC420978 - Revise valve factor for 1(2)NI173A & | |||
1(2)NI178B | |||
000 | |||
CNC -1205.19-00- | |||
0179 | |||
Kalsi Engineering Report 2919C, GL96-05 Periodic | |||
Verification Program for Butterfly Valves with 316 | |||
Microseal Bearings {JOG Class D) | Microseal Bearings {JOG Class D) | ||
CNC -1381.05-00- U2, 6.9KV, 4.16KV, & 600V Auxiliary Power Systems | CNC -1381.05-00- | ||
0199 | |||
CNC-1205.00-00- GL 95-07 Pressure Locking and Thermal Binding Review | U2, 6.9KV, 4.16KV, & 600V Auxiliary Power Systems | ||
Safety-Related Voltage Analysis | |||
CNC-1205.19-00- Operability Evaluation of Rotork Part 21 for Switch | CNC-1205.00-00- | ||
0048 | |||
CNM 1205.00- | GL 95-07 Pressure Locking and Thermal Binding Review | ||
of Valves Without an Active to Open Safety Function | |||
CNC-1205.19-00- | |||
0170 | |||
Operability Evaluation of Rotork Part 21 for Switch | |||
Mechanisms | |||
CNM 1205.00- | |||
0549.001 | 0549.001 | ||
CNM 1205.00- Design and Seismic Analysis Report for 3" EMO Gate | ASME Section III Gate Valve Seismic Report | ||
CNM 1205.00- | |||
CNM 1205.02- | 2050.001 | ||
Design and Seismic Analysis Report for 3" EMO Gate | |||
Valve, Item 9J-364 | |||
00C | |||
CNM 1205.02- | |||
0766.001 | 0766.001 | ||
CNM 1205.19-Stress Report for Westinghouse Class 1 Nuclear Valves- | Weak-Link Report for CNS BFV Item Number 05B-501 | ||
CNM 1205.19- | |||
CNM 1205.19-9J-211 Seismic and Weak Link Analysis Report for | 0094.001 | ||
Stress Report for Westinghouse Class 1 Nuclear Valves- | |||
Inspection Type Designation Description or Title Revision or | Gate Valves | ||
D3 | |||
DPC 1205.41-00- | Engineering | ||
Evaluations | |||
CNM 1205.19- | |||
099.011 | |||
9J-211 Seismic and Weak Link Analysis Report for | |||
Westinghouse Class 1 Nuclear Valve | |||
Inspection | |||
Procedure | |||
Type | |||
Designation | |||
Description or Title | |||
Revision or | |||
Date | |||
DPC 1205.41-00- | |||
0001 | 0001 | ||
DPC-1205.00-00- Microseal Bearing Test Report: Kalsi Engineering | Evaluation of AOV Issues Needed for Margin Calculations | ||
DPC-1205.00-00- | |||
0008 | |||
BACKGROUND | Microseal Bearing Test Report: Kalsi Engineering | ||
Document 2800C | |||
[N/A] | |||
OAC Alarm Response Information for loss of SOV Power | |||
BACKGROUND | |||
INFORMATION | INFORMATION | ||
FOR | FOR | ||
| Line 260: | Line 431: | ||
RESPONSE | RESPONSE | ||
GUIDELINE | GUIDELINE | ||
CDUK-1205.41- | ES-1.3 Transfer to Cold Leg Recirculation HP-Rev. 3 | ||
03/31/2014 | |||
CDUK-1205.41- | |||
0001.001 | 0001.001 | ||
CE 0000106724 Revise MOV Set-Up Sheets to Meet GL 96-05 | Unit 1 and Unit 2 AOV Test Set Up Sheets | ||
CE 0000106724 | |||
Revise MOV Set-Up Sheets to Meet GL 96-05 | |||
Requirements for 1KC001A, 002B, 050A, AND 053B | Requirements for 1KC001A, 002B, 050A, AND 053B | ||
CN 500404 Allow Replacement of Solenoid Valves w/ New Model 05/17/2005 | 09/17/2012 | ||
CN-11413 De-energize the Hydraulic Solenoids on the Main | CN 500404 | ||
Allow Replacement of Solenoid Valves w/ New Model | |||
05/17/2005 | |||
CN-11413 | |||
De-energize the Hydraulic Solenoids on the Main | |||
Feedwater Isolation Valves | Feedwater Isolation Valves | ||
CNC -1205.19-00- EC420956-Revise Valve Factor and Functions for CA | 08/06/2001 | ||
CNC -1205.19-00- | |||
CNM 1205.00- | 0176-ICC-0004 | ||
EC420956-Revise Valve Factor and Functions for CA | |||
MOVs | |||
CNM 1205.00- | |||
22.001 | 22.001 | ||
CNM 1205.00- | l/B Manual M/0 Gate Valves & Swing Check Vlvs | ||
D10 | |||
CNM 1205.00- | |||
1997.001 | 1997.001 | ||
CNM 1205.00- | EMO Torque Switch Setting Sheets | ||
CNM 1205.00- | |||
1997.001 | 1997.001 | ||
CNM 1205.00- Instruction Manual Number ET347 for 3" 1530 Class | EMO Torque Switch Setting Sheets | ||
CNM 1205.00- | |||
CNM 1205.02- | 2049-001 | ||
Instruction Manual Number ET347 for 3" 1530 Class | |||
Double Disc Gate Valves with Motor Actuators | |||
10/01/1997 | |||
CNM 1205.02- | |||
0762.001 | 0762.001 | ||
CNM 1205.06-I/M & Parts List for Control Valves and Regulators | Posi-Seal Butterfly Valve Technical Bulletin Series | ||
Inspection Type Designation Description or Title Revision or | Miscellaneous | ||
CNM 1205.06- | |||
I/M & Parts List for Control Valves and Regulators | |||
Inspection | |||
Procedure | |||
Type | |||
Designation | |||
Description or Title | |||
Revision or | |||
Date | |||
268.001 | 268.001 | ||
CNM 1205.19- | CNM 1205.19- | ||
0001.001 | 0001.001 | ||
CNM 1205.19-Technical Repair Guide for Rotork Valve Actuators "NA" | Limitorque Nuclear Qualification Reports | ||
CNM 1205.19- | |||
CNM 1205.19- | 0083.001 | ||
Technical Repair Guide for Rotork Valve Actuators "NA" | |||
Range Models | |||
CNM 1205.19- | |||
0114.001 | 0114.001 | ||
CNS-1205.00-00- ASME Section 3 Stainless Steel Gate Globe and Check | Rotork Motor Operator Bench Test Certificates | ||
D7 | |||
CNS-1205.06-00- | CNS-1205.00-00- | ||
0008 | |||
ASME Section 3 Stainless Steel Gate Globe and Check | |||
Valves | |||
CNS-1205.06-00- | |||
0003 | 0003 | ||
CNS-1553.NC-00- | Control Valves to ASME Section III | ||
CNS-1553.NC-00- | |||
0001 | 0001 | ||
CNS-1554.NV-00- Chemical and Volume Control System (NV) Design Basis | Reactor Coolant System (NC) Design Basis Specification | ||
CNS-1554.NV-00- | |||
CNS-1561.ND-00- Design Basis Specification for The Residual Heat | 0001 | ||
Chemical and Volume Control System (NV) Design Basis | |||
CNS-1562.NI-00- Design Basis Specification For the Safety Injection (NI) | Specification | ||
CNS-1561.ND-00- | |||
CNS-1573.KC-00- Component Cooling System (KC) Design Basis | 0001 | ||
Design Basis Specification for The Residual Heat | |||
CNS-1591.CF-00- Design Basis Specification for the Feedwater (CF) Rev. 034 | Removal (ND) System | ||
CNS-1562.NI-00- | |||
CNS-1592.CA-00- Auxiliary Feedwater System (CA) Design Basis | 0001 | ||
Design Basis Specification For the Safety Injection (NI) | |||
CNS-1592.CA-00- Auxiliary Feedwater System (CA) Design Basis | System | ||
CNS-1573.KC-00- | |||
DPS 1205.00-00- Nuclear Safety Related Carbon and Stainless Steel | 0001 | ||
Component Cooling System (KC) Design Basis | |||
DPS-1205.19-00- | Specification | ||
CNS-1591.CF-00- | |||
0001 | |||
Design Basis Specification for the Feedwater (CF) | |||
System | |||
Rev. 034 | |||
CNS-1592.CA-00- | |||
0001 | |||
Auxiliary Feedwater System (CA) Design Basis | |||
Specification | |||
CNS-1592.CA-00- | |||
0001 | |||
Auxiliary Feedwater System (CA) Design Basis | |||
Specification | |||
DPS 1205.00-00- | |||
0002 | |||
Nuclear Safety Related Carbon and Stainless Steel | |||
Forged and Cast Electric Motor Operated Valves | |||
DPS-1205.19-00- | |||
0004 | 0004 | ||
EQMM-1393.01-Environmental Qualification Maintenance Manual | Safety Related Rotork Motor Operators and Spare Parts | ||
EQMM-1393.01- | |||
Q03-01 | |||
Environmental Qualification Maintenance Manual | |||
Equipment Type: Solenoid Valve Manufacturer: Valcor | |||
Engineering Corporation Model/Series: V70900-65 Series | Engineering Corporation Model/Series: V70900-65 Series | ||
Inspection Type Designation Description or Title Revision or | |||
Inspection | |||
Procedure | |||
Type | |||
Designation | |||
Description or Title | |||
Revision or | |||
Date | |||
Valves | Valves | ||
OEDB Number: LIMITORQUE TECHNICAL UPDATE #92-O1 Kalsi | OEDB Number: | ||
2-12415 | |||
LIMITORQUE TECHNICAL UPDATE #92-O1 Kalsi | |||
Engineering Document #17O7-C, Rev. o (11-25-91) | |||
Thrust Rating Increase SMB-OOO, SMB-OO, SMB-O & | Thrust Rating Increase SMB-OOO, SMB-OO, SMB-O & | ||
SMB-1 Actuators | SMB-1 Actuators | ||
OP-CN-CF-CF Feedwater System Lesson Plan 04/07/2014 | 01/06/1992 | ||
OP-CN-EP-INTRO Emergency Procedures Intro Lesson Plan CNOB50 | OP-CN-CF-CF | ||
System Health | Feedwater System Lesson Plan | ||
04/07/2014 | |||
OP-CN-EP-INTRO | |||
Emergency Procedures Intro Lesson Plan CNOB50 | |||
System Health | |||
Report | Report | ||
KC - Component Cooling System | |||
04/19/2022 | |||
System Health | |||
Report | Report | ||
ND - Residual Heat Removal System | |||
04/19/2022 | |||
System Health | |||
Report | Report | ||
Torque and | CA - CNS l Unit 2 l CA - Auxiliary Feedwater System | ||
04/19/2022 | |||
Torque and | |||
Margin for 1ND27 | Margin for 1ND27 | ||
As Left C1R26 | |||
10/23/2021 | |||
Westinghouse | |||
Guideline | Guideline | ||
Document | Document | ||
ES-1.3 Transfer to Cold Leg Recirculation HP-Rev 3 | |||
AD-EG-ALL-1433 Air Operated Valve Testing Requirements | 03/31/2014 | ||
AD-OP-ALL-0105 Operability Determinations | AD-EG-ALL-1432 | ||
AD-OP-ALL-0205 Time Critical Actions/Time Sensitive Actions | Air Operated Valve Design Basis Review | ||
CNC-1205.19-00- JOG Classification of Catawbas GL96-05 MOV | AD-EG-ALL-1433 | ||
Air Operated Valve Testing Requirements | |||
DPS-1205.19-00- Guideline for Performing Motor Operated Valve Reviews | AD-OP-ALL-0105 | ||
Operability Determinations | |||
EP/2/A/5000/E-3 CNS Steam Generator Tube Rupture | AD-OP-ALL-0205 | ||
EP/2/A/5000/ES- | Time Critical Actions/Time Sensitive Actions | ||
CNC-1205.19-00- | |||
0176 | |||
JOG Classification of Catawbas GL96-05 MOV | |||
Population | |||
DPS-1205.19-00- | |||
0002 | |||
Guideline for Performing Motor Operated Valve Reviews | |||
and Calculations (For Engineering use only) | |||
EP/2/A/5000/E-3 | |||
CNS Steam Generator Tube Rupture | |||
EP/2/A/5000/ES- | |||
1.3 | 1.3 | ||
IP/0/A/3820/004 Q MOV Diagnostic Testing | Transfer to Cold Leg Recirculation | ||
IP/0/A/3820/004 Q MOV Diagnostic Testing | IP/0/A/3820/004 Q | ||
IP/0/A/3820/034 Removal/Restoration of Interferences and Packing Re- | MOV Diagnostic Testing | ||
IP/0/A/3820/004 Q | |||
MOV Diagnostic Testing | |||
IP/0/A/3820/034 | |||
Removal/Restoration of Interferences and Packing Re- | |||
Torque on Air Operated Valves (AOVs) | Torque on Air Operated Valves (AOVs) | ||
IP/0/A/3820/047 AOV Diagnostic Testing using the QUIKLOOK3 System | Procedures | ||
Inspection Type Designation Description or Title Revision or | IP/0/A/3820/047 | ||
AOV Diagnostic Testing using the QUIKLOOK3 System | |||
OP/1/A/6100/010K Annunciator Response for Panel 1AD-10 | Inspection | ||
OP/1/B/6100/010 Annunciator Response for Radiation Monitoring Panel | Procedure | ||
Type | |||
OP/1/B/6100/010 Annunciator Response for Radiation Monitoring Panel | Designation | ||
Description or Title | |||
PD-EG-ALL-1430 Air Operated Valve Program | Revision or | ||
PT/0/A/4700/061 Time Critical Actions/ Time Sensitive Actions | Date | ||
PT/1/A/4200/021 | OP/1/A/6100/010K | ||
Annunciator Response for Panel 1AD-10 | |||
OP/1/B/6100/010 | |||
X | |||
Annunciator Response for Radiation Monitoring Panel | |||
1RAD-1 | |||
OP/1/B/6100/010 | |||
Z | |||
Annunciator Response for Radiation Monitoring Panel | |||
1RAD-3 | |||
PD-EG-ALL-1430 | |||
Air Operated Valve Program | |||
PT/0/A/4700/061 | |||
Time Critical Actions/ Time Sensitive Actions | |||
PT/1/A/4200/021 | |||
A | A | ||
PT/2/4/4200/013 NI Valve Inservice Test (UNK) 41, | KC Valve Inservice Test (QU) | ||
PT/2/4/4200/013 | |||
G | |||
NI Valve Inservice Test (UNK) | |||
41, | |||
completed | |||
04/11/2021 | 04/11/2021 | ||
PT/2/A/4200/0 CA Valve Inservice Test (QU) 13E | PT/2/A/4200/0 | ||
PT/2/A/4200/013 | CA Valve Inservice Test (QU) | ||
13E | |||
PT/2/A/4200/013 | |||
E | E | ||
PT/2/A/4200/023 NC Valve Inservice Test (QU) 21, | CA Valve Inservice Test (QU) | ||
PT/2/A/4200/023 | |||
NC Valve Inservice Test (QU) | |||
21, | |||
completed | completed | ||
03/22/2022 | 03/22/2022 | ||
PT/2/A/4200/079 Auxiliary Feedwater Flow Control Valve Air Accumulator | PT/2/A/4200/079 | ||
Auxiliary Feedwater Flow Control Valve Air Accumulator | |||
Leakage Test | Leakage Test | ||
PT/l/A/4200/001 T Containment Penetration Valve Injection Water System | PT/l/A/4200/001 T | ||
Containment Penetration Valve Injection Water System | |||
Performance Test | Performance Test | ||
PT/l/A/4200/013 I NV Valve Inservice Test | PT/l/A/4200/013 I | ||
SI/0/A/5200/006 MOV Actuator Lubrication and Inspection | NV Valve Inservice Test | ||
SI/0/A/5200/006 | |||
MOV Actuator Lubrication and Inspection | |||
WO 1899772 | |||
ASSIST THE C.C.I. TECH IN REASSEMBLING THE | |||
C.F.I.V. VALVES | C.F.I.V. VALVES | ||
WO 20338520 01 1. Duke_WorkOrderPackage_Rpt_B 1CF - REPLACE | 2/16/2009 | ||
WO 20338520 01 | |||
1. Duke_WorkOrderPackage_Rpt_B 1CF - REPLACE | |||
HYDRAULIC FLUID/INSPECT DESICCANT FOR CFIV 2. | HYDRAULIC FLUID/INSPECT DESICCANT FOR CFIV 2. | ||
IP/0/A/3010/024 MAIN FEEDWATER (CF) SYSTEM | IP/0/A/3010/024 MAIN FEEDWATER (CF) SYSTEM | ||
FEEDWATER ISOLATION | FEEDWATER ISOLATION | ||
WOs | 05/17/2020 | ||
Work Orders | |||
WOs | |||
2050985, 20341710 01, 20436333 01, 20444997 02, | |||
204646 01, 02119855 01, 20407902 01, 20380724 01 | 204646 01, 02119855 01, 20407902 01, 20380724 01 | ||
11 | 11 | ||
}} | }} | ||
Latest revision as of 16:21, 27 November 2024
| ML22202A530 | |
| Person / Time | |
|---|---|
| Site: | Catawba |
| Issue date: | 07/21/2022 |
| From: | James Baptist NRC/RGN-II/DRS/EB1 |
| To: | Simril T Duke Energy Carolinas |
| References | |
| IR 2022010 | |
| Download: ML22202A530 (13) | |
Text
July 21, 2022
SUBJECT:
CATAWBA NUCLEAR STATION - DESIGN BASIS ASSURANCE INSPECTION (PROGRAMS) INSPECTION REPORT 05000413/2022010 AND 05000414/2022010
Dear Mr. Simril:
On June 10, 2022, the U.S. Nuclear Regulatory Commission (NRC) completed an inspection at Catawba Nuclear Station and discussed the results of this inspection with you and other members of your staff. The results of this inspection are documented in the enclosed report.
No findings or violations of more than minor significance were identified during this inspection.
This letter, its enclosure, and your response (if any) will be made available for public inspection and copying at http://www.nrc.gov/reading-rm/adams.html and at the NRC Public Document Room in accordance with Title 10 of the Code of Federal Regulations 2.390, Public Inspections, Exemptions, Requests for Withholding.
Sincerely, James B. Baptist, Chief Engineering Branch 1 Division of Reactor Safety Docket Nos. 05000413 and 05000414 License Nos. NPF-35 and NPF-52
Enclosure:
As stated
Inspection Report
Docket Numbers:
05000413 and 05000414
License Numbers:
Report Numbers:
05000413/2022010 and 05000414/2022010
Enterprise Identifier: I-2022-010-0038
Licensee:
Duke Energy Carolinas, LLC
Facility:
Catawba Nuclear Station
Location:
York, SC
Inspection Dates:
May 23, 2022, to June 10, 2022
Inspectors:
R. Fanner, Reactor Inspector
N. Morgan, Intergovernmental Liaison Project Manager
G. Ottenberg, Senior Reactor Inspector
J. Zudans, Contractor
Approved By:
James B. Baptist, Chief
Engineering Branch 1
Division of Reactor Safety
Enclosure
SUMMARY
The U.S. Nuclear Regulatory Commission (NRC) continued monitoring the licensees performance by conducting a design basis assurance inspection (programs) inspection at Catawba Nuclear Station, in accordance with the Reactor Oversight Process. The Reactor Oversight Process is the NRCs program for overseeing the safe operation of commercial nuclear power reactors. Refer to https://www.nrc.gov/reactors/operating/oversight.html for more information.
List of Findings and Violations
No findings or violations of more than minor significance were identified.
Additional Tracking Items
None.
INSPECTION SCOPES
Inspections were conducted using the appropriate portions of the inspection procedures (IPs) in effect at the beginning of the inspection unless otherwise noted. Currently approved IPs with their attached revision histories are located on the public website at http://www.nrc.gov/reading-rm/doc-collections/insp-manual/inspection-procedure/index.html. Samples were declared complete when the IP requirements most appropriate to the inspection activity were met consistent with Inspection Manual Chapter (IMC) 2515, Light-Water Reactor Inspection Program - Operations Phase. The inspectors reviewed selected procedures and records, observed activities, and interviewed personnel to assess licensee performance and compliance with Commission rules and regulations, license conditions, site procedures, and standards.
REACTOR SAFETY
71111.21N.02 - Design-Basis Capability of Power-Operated Valves Under 10 CFR 50.55a Requirements POV Review (IP Section 03)
The inspectors:
a. Evaluated whether the sampled POVs are being tested and maintained in accordance with NRC regulations along with the licensees commitments and/or licensing bases.
Specific Guidance b. Evaluated whether the sampled POVs are capable of performing their design-basis functions.
c. Evaluated whether testing of the sampled POVs is adequate to demonstrate the capability of the POVs to perform their safety functions under design-basis conditions.
d. Evaluated maintenance activities including a walkdown of the sampled POVs (if accessible).
(1)1KC050A, Auxiliary Building Non-Essential Header Isolation (2)1ND027, 1A Residual Heat Removal (ND) Heat Exchanger Bypass Control (3)2CA050A, Auxiliary Feedwater (CA) Pump 2 Discharge to Steam Generator 2C Isolation (4)1NV010A, Letdown Orifice 1B Outlet Containment Isolation (5)2CA056, CA Pump 2A Flow to Steam Generator 2B (6)2NC035B, Pressurizer Power Operated Relief Valve Isolation (7)2NI173A, ND Header 2A to Cold Legs C & D (8)1CF033, 1A Steam Generator Feedwater Containment Isolation
INSPECTION RESULTS
No findings were identified.
EXIT MEETINGS AND DEBRIEFS
The inspectors verified no proprietary information was retained or documented in this report.
On June 10, 2022, the inspectors presented the design basis assurance inspection (programs) inspection results to Tom Simril and other members of the licensee staff.
DOCUMENTS REVIEWED
Inspection
Procedure
Type
Designation
Description or Title
Revision or
Date
71111.21N.02
Calculations
AD-EG-ALL-1117
U2, 6.9KV, 4.16KV, & 600V Auxiliary Power Systems
Safety-Related Voltage Analysis
CNC -1205.19-00-
Generic Letter 89-10 MOV Calculations, NC System; 1(2)
28
NC033A, 035B, 1NC031B
CNC -1205.19-00-
89-10 Calculation for 1&2 CA038A, 42B, 46B, 50A, 54B,
29
58A, 62A, 66B
CNC -1205.19-00-
Generic Letter 89-10 Calculation For Valves 1 and
0033
NI173A and NI178B
CNC -1205.19-00-
GL 89-10 Set-Up Calculation for Valves 1KC001A,
0110
1KC002B, 1KC050A, 1KC053B, 2KC001A, AND
2KC002B
CNC -1205.19-00-
Required Thrust Calculation for 1(2)NC31B, 33A, 35B
000
0195
(AD/DD PPM); Item NO. 09J-363 & 364
CNC -1205.41-00-
(2) ND 26, 27, 60, and 61 Fisher Actuator and Margin
27
Capability Calculations
CNC -1206.02-80-
KCC - Component Cooling Heat Exchangers 1 A & 1 B to
018
2019
the RHR Heat Exchangers 1A & 1 B. Also to the Inlet of
the Letdown & Fuel Pool Heat Exchangers
CNC -1223.11-00-
Limiting 1ST Stroke Time for ND26, ND27, ND60 and
000
0055
ND6V
CNC -1381.05-00-
U2, 6.9KV, 4.16KV, & 600V AUXILIARY POWER
0199
SYSTEMS SAFETY-RELATED VOLTAGE ANALYSIS
CNC 1205.41-00-
(2) NV 010A, 011A, and 013A Required Thrust
0018
Evaluation supporting Air Operated Valve (AOV) Program
CNC-1205.41-00-
Air Operated Valve (AOV) Program Scope Calculation
0001
CNC-1205.41-00-
FEEDWATER ISOLATION VALVES, 1(2)CF33, 42, 51,
05/03/2022
0005
AND
60, DESIGN BASIS SIZING CALCULATION
CNC-1205.41-00-
Catawba Air-operated Valve (AOV) Risk Ranking
0016
Calculation
CNC-1205.41-00-
(2) NV 010A, 011A, and 013A Required Thrust
Inspection
Procedure
Type
Designation
Description or Title
Revision or
Date
0018
Evaluation supporting Air Operated Valve (AOV) Program
CNC-1205.41-00-
1(2) CA-040, 044, 056, 060 and 1(2) CA-036, 048, 052,
22
064 Actuator Capability Evaluation Supporting Air
Operated (AOV) Program
CNC-1206.03-00-
Doghouse Environmental Temperature Due to Main
Rev. 3
0181
Steam Line Break
CNC-1223.02-00-
Inservice Testing (IST) Valve Response Measurement
04/08/2011
23
Uncertainty
CNC-1223.12-00-
Design Parameters for ND Header to Cold Leg
0045
Containment Isolation Valves 1 & 2 NI173A, NI178B
CNC-1552.08-00-
Long-Term Containment Response - Manual NS Initiation
0390
CNM 1205.00-
Design/Seismic Report (Weak Link) for 09J-2056, 2",
2182.001
1500#, SS, Gate Valve
CNM 1205.01-
C
0797.001
Corrective Action
2373087, 02294259, 01497427, 02407695, 02294259,
Documents
01497427, 02428219, 01898027, 02300922
Corrective Action
OP-CN-CF-CF lesson plan does not identify the safety
06/24/2022
Documents
related power supply for Feedwater Isolation Valve's
Resulting from
22 NRC DBAI POV - 2NI173A Motor Brake Internals
06/02/2022
Inspection
22 NRC DBAI POV - 1KC-50A Maximum Transmitted
06/06/2022
22 NRC DBAI POV - Lesson Plans not revised post
06/07/2022
Mod
PT/1/A/4350/002 E enclosure 13.16 could not be located
06/07/2022
22 NRC POV DBAI - Incorrect Reference in Flowserve
06/07/2022
Letter
Obstructions on 522' elevation floor drains
06/08/2022
NRC DBAI POV-EOPs do not align with UFSAR
06/09/2022
22 NRC DBAI POV - 2NC35B - Actuator Fastener Bolt
06/09/2022
Preload
22 NRC DBAI POV - UFSAR sec.6.2.4.1 incorrect
06/14/2022
statement
Inspection
Procedure
Type
Designation
Description or Title
Revision or
Date
NCR 2428952
22 NRC DBAI POV - 2NC035B High Temp Torque
Factor
05/26/2022
NCR 2430567
NRC DBAI POV-EOPs do not align with UFSAR
06/09/2022
2-403-0012-3
Limitorque Valve Control
DI
40846-08
20- Class 150 Valve Assembly and Limitorque H2BC-
SMB-00-10
CN -1561-01.00
Flow Diagram of Residual Heat Removal System (ND)
CN -2561-01.00
Flow Diagram of Residual Heat Removal System (ND)
CN -2562-01.01
Flow Diagram, Safety Injection System (NI)
CN -2592-01.01
Flow Diagram Auxiliary Feedwater System (CA)
CN-1573-01.0
Flow Diagram of Component Cooling System (KC)
CN-2499-CA.07-
Instrument Detail Motor Driven Auxiliary Feedwater Pump
to Steam Generator Flow Control
CN-2553-01.01
Flow Diagram of Reactor Coolant System (NC)
CN-2562-01.03
Flow Diagram of Safety Injection System (NI)
CNEE-0247-04.12
Auxiliary Feedwater System (CA) CA Pump No. 2 Disch
to S/D 2C Isol. Vlv. 2CA050A
CNEE-0247-
04.12-01
Auxiliary Feedwater System (CA) CA Pump No. 2 Disch
to S/D 2C Isol. Vlv. 2CA050A Controls
CNEE-0250-01.09
Reactor Coolant System (NC) Pzr Power Operated Relief
Isolation Valve 2NC035B
CNEE-0251-01.32
Elementary Diagram Safety Injection System (NI) ND
HDR to NC Cold Legs C and D Isolation Valve 2NI173A
CNM 1205.00-
0074.001
8"SS Motor Oper Gate Vlv Item 9J211
CNM 1205.00-
2181.001
O/L Drawing for 09J-2056, 2", 1500#, SS, Gate Valve
CNM 1205.01-
0790.001
4" 1500LB CS EMO DP Gate Valve 6J-339
H
CNM 1205.01-
0790.002
4" 1500LB CS DP Gate Valve 6J-339
J
CNM 1205.06-
20.001
O/L, C/S, B/M, OPR, W/D Control Valves 1&2/CA/40, 44,
& 60
J
Drawings
W9223811, Sht. 1
3"- 1530 Weld Ends Stainless Steel Double Disc Gate
B
Inspection
Procedure
Type
Designation
Description or Title
Revision or
Date
Valve for SMB-00-15 Limitorque Actuator
W9223811, Sht. 2
3"- 1530 Weld Ends Stainless Steel Double Disc Gate
Valve for SMB-00-15 Limitorque Actuator
B
CN 20328
Modify control circuit wiring on 2NI-9A, 10B, 100B, 183B,
2A, 173A, 178B, 184B, 185A, 2NV-89A, 91B, 188A,
189B, 252A, 253B, 312A, and 314B to provide "limit
actuated" torque switch bypass contacts which can be
adjusted independent of Indication or interlocks.
11/07/1988
CN 21319
Modify CA Control Valves to Prevent S/G Overfill During
08/11/1999
Revise MOV Set-Up Sheets to Meet GL 96-05
Requirements for 1KC001A, 002B, 050A
09/07/2012
Engineering
Changes
U-1 AND U-2 NW System Isolation to Specific CIVs
CNC -1205.19-00-
0176-ICC-0003
EC420978 - Revise valve factor for 1(2)NI173A &
1(2)NI178B
000
CNC -1205.19-00-
0179
Kalsi Engineering Report 2919C, GL96-05 Periodic
Verification Program for Butterfly Valves with 316
Microseal Bearings {JOG Class D)
CNC -1381.05-00-
0199
U2, 6.9KV, 4.16KV, & 600V Auxiliary Power Systems
Safety-Related Voltage Analysis
CNC-1205.00-00-
0048
GL 95-07 Pressure Locking and Thermal Binding Review
of Valves Without an Active to Open Safety Function
CNC-1205.19-00-
0170
Operability Evaluation of Rotork Part 21 for Switch
Mechanisms
CNM 1205.00-
0549.001
ASME Section III Gate Valve Seismic Report
CNM 1205.00-
2050.001
Design and Seismic Analysis Report for 3" EMO Gate
Valve, Item 9J-364
00C
CNM 1205.02-
0766.001
Weak-Link Report for CNS BFV Item Number 05B-501
CNM 1205.19-
0094.001
Stress Report for Westinghouse Class 1 Nuclear Valves-
Gate Valves
D3
Engineering
Evaluations
CNM 1205.19-
099.011
9J-211 Seismic and Weak Link Analysis Report for
Westinghouse Class 1 Nuclear Valve
Inspection
Procedure
Type
Designation
Description or Title
Revision or
Date
DPC 1205.41-00-
0001
Evaluation of AOV Issues Needed for Margin Calculations
DPC-1205.00-00-
0008
Microseal Bearing Test Report: Kalsi Engineering
Document 2800C
[N/A]
OAC Alarm Response Information for loss of SOV Power
BACKGROUND
INFORMATION
FOR
OWNERS
GROUP
EMERGENCY
RESPONSE
GUIDELINE
ES-1.3 Transfer to Cold Leg Recirculation HP-Rev. 3
03/31/2014
CDUK-1205.41-
0001.001
Unit 1 and Unit 2 AOV Test Set Up Sheets
CE 0000106724
Revise MOV Set-Up Sheets to Meet GL 96-05
Requirements for 1KC001A, 002B, 050A, AND 053B
09/17/2012
CN 500404
Allow Replacement of Solenoid Valves w/ New Model
05/17/2005
CN-11413
De-energize the Hydraulic Solenoids on the Main
Feedwater Isolation Valves
08/06/2001
CNC -1205.19-00-
0176-ICC-0004
EC420956-Revise Valve Factor and Functions for CA
CNM 1205.00-
22.001
l/B Manual M/0 Gate Valves & Swing Check Vlvs
D10
CNM 1205.00-
1997.001
EMO Torque Switch Setting Sheets
CNM 1205.00-
1997.001
EMO Torque Switch Setting Sheets
CNM 1205.00-
2049-001
Instruction Manual Number ET347 for 3" 1530 Class
Double Disc Gate Valves with Motor Actuators
10/01/1997
CNM 1205.02-
0762.001
Posi-Seal Butterfly Valve Technical Bulletin Series
Miscellaneous
CNM 1205.06-
I/M & Parts List for Control Valves and Regulators
Inspection
Procedure
Type
Designation
Description or Title
Revision or
Date
268.001
CNM 1205.19-
0001.001
Limitorque Nuclear Qualification Reports
CNM 1205.19-
0083.001
Technical Repair Guide for Rotork Valve Actuators "NA"
Range Models
CNM 1205.19-
0114.001
Rotork Motor Operator Bench Test Certificates
D7
CNS-1205.00-00-
0008
ASME Section 3 Stainless Steel Gate Globe and Check
Valves
CNS-1205.06-00-
0003
Control Valves to ASME Section III
CNS-1553.NC-00-
0001
Reactor Coolant System (NC) Design Basis Specification
CNS-1554.NV-00-
0001
Chemical and Volume Control System (NV) Design Basis
Specification
CNS-1561.ND-00-
0001
Design Basis Specification for The Residual Heat
Removal (ND) System
CNS-1562.NI-00-
0001
Design Basis Specification For the Safety Injection (NI)
System
CNS-1573.KC-00-
0001
Component Cooling System (KC) Design Basis
Specification
CNS-1591.CF-00-
0001
Design Basis Specification for the Feedwater (CF)
System
Rev. 034
CNS-1592.CA-00-
0001
Auxiliary Feedwater System (CA) Design Basis
Specification
CNS-1592.CA-00-
0001
Auxiliary Feedwater System (CA) Design Basis
Specification
DPS 1205.00-00-
0002
Nuclear Safety Related Carbon and Stainless Steel
Forged and Cast Electric Motor Operated Valves
DPS-1205.19-00-
0004
Safety Related Rotork Motor Operators and Spare Parts
EQMM-1393.01-
Q03-01
Environmental Qualification Maintenance Manual
Equipment Type: Solenoid Valve Manufacturer: Valcor
Engineering Corporation Model/Series: V70900-65 Series
Inspection
Procedure
Type
Designation
Description or Title
Revision or
Date
Valves
OEDB Number:
2-12415
LIMITORQUE TECHNICAL UPDATE #92-O1 Kalsi
Engineering Document #17O7-C, Rev. o (11-25-91)
Thrust Rating Increase SMB-OOO, SMB-OO, SMB-O &
SMB-1 Actuators
01/06/1992
OP-CN-CF-CF
Feedwater System Lesson Plan
04/07/2014
OP-CN-EP-INTRO
Emergency Procedures Intro Lesson Plan CNOB50
System Health
Report
KC - Component Cooling System
04/19/2022
System Health
Report
ND - Residual Heat Removal System
04/19/2022
System Health
Report
CA - CNS l Unit 2 l CA - Auxiliary Feedwater System
04/19/2022
Torque and
Margin for 1ND27
As Left C1R26
10/23/2021
Guideline
Document
ES-1.3 Transfer to Cold Leg Recirculation HP-Rev 3
03/31/2014
AD-EG-ALL-1432
Air Operated Valve Design Basis Review
AD-EG-ALL-1433
Air Operated Valve Testing Requirements
AD-OP-ALL-0105
AD-OP-ALL-0205
Time Critical Actions/Time Sensitive Actions
CNC-1205.19-00-
0176
JOG Classification of Catawbas GL96-05 MOV
Population
DPS-1205.19-00-
0002
Guideline for Performing Motor Operated Valve Reviews
and Calculations (For Engineering use only)
EP/2/A/5000/E-3
CNS Steam Generator Tube Rupture
EP/2/A/5000/ES-
1.3
Transfer to Cold Leg Recirculation
IP/0/A/3820/004 Q
MOV Diagnostic Testing
IP/0/A/3820/004 Q
MOV Diagnostic Testing
IP/0/A/3820/034
Removal/Restoration of Interferences and Packing Re-
Torque on Air Operated Valves (AOVs)
Procedures
IP/0/A/3820/047
AOV Diagnostic Testing using the QUIKLOOK3 System
Inspection
Procedure
Type
Designation
Description or Title
Revision or
Date
OP/1/A/6100/010K
Annunciator Response for Panel 1AD-10
OP/1/B/6100/010
X
Annunciator Response for Radiation Monitoring Panel
OP/1/B/6100/010
Z
Annunciator Response for Radiation Monitoring Panel
PD-EG-ALL-1430
Air Operated Valve Program
PT/0/A/4700/061
Time Critical Actions/ Time Sensitive Actions
PT/1/A/4200/021
A
KC Valve Inservice Test (QU)
PT/2/4/4200/013
G
NI Valve Inservice Test (UNK)
41,
completed
04/11/2021
PT/2/A/4200/0
CA Valve Inservice Test (QU)
13E
PT/2/A/4200/013
E
CA Valve Inservice Test (QU)
PT/2/A/4200/023
NC Valve Inservice Test (QU)
21,
completed
03/22/2022
PT/2/A/4200/079
Auxiliary Feedwater Flow Control Valve Air Accumulator
Leakage Test
PT/l/A/4200/001 T
Containment Penetration Valve Injection Water System
Performance Test
PT/l/A/4200/013 I
NV Valve Inservice Test
SI/0/A/5200/006
MOV Actuator Lubrication and Inspection
ASSIST THE C.C.I. TECH IN REASSEMBLING THE
C.F.I.V. VALVES
2/16/2009
WO 20338520 01
1. Duke_WorkOrderPackage_Rpt_B 1CF - REPLACE
HYDRAULIC FLUID/INSPECT DESICCANT FOR CFIV 2.
IP/0/A/3010/024 MAIN FEEDWATER (CF) SYSTEM
FEEDWATER ISOLATION
05/17/2020
Work Orders
2050985, 20341710 01, 20436333 01, 20444997 02,
204646 01, 02119855 01, 20407902 01, 20380724 01
11