ML21361A257: Difference between revisions

From kanterella
Jump to navigation Jump to search
(StriderTol Bot insert)
 
(StriderTol Bot change)
Line 16: Line 16:


=Text=
=Text=
{{#Wiki_filter:ES-401                                   Generic Knowledge and Abilities Outline (Tier 3)                                   Form ES-401-3 Facility: Byron Nuclear Generating Station                                                                     Date of Exam: September 2021 Category             K/A #                                           Topic                                           RO         SRO-Only IR       #     IR       #
{{#Wiki_filter:ES-401 Generic Knowledge and Abilities Outline (Tier 3) Form ES-401-3
2.1.2   Knowledge of operator responsibilities during all modes of plant operation.         4.1   66
 
: 1.                           (CFR: 41.10 / 45.13)
Facility: Byron Nuclear Generating Station Date of Exam: September 2021
Knowledge of criteria or conditions that require plant-wide announcements, Conduct              2.1.14                                                                                      3.1   67 such as pump starts, reactor trips, mode changes, etc.
 
of Operations                (CFR: 41.10 / 43.5 / 45.12) 2.1.7   Ability to evaluate plant performance and make operational judgements               4.4   68 based on operating characteristics, reactor behavior, and instrument interpretation.
Category K/A # Topic RO SRO-Only IR # IR #
(CFR: 41.7 / 43.5 / 45.4) 2.1.35   Knowledge of the fuel-handling responsibilities of SROs.                                           3.9   94 (CFR: 41.10 / 43.7) 2.1.39   Knowledge of conservative decision-making practices.                                               4.3   95 (CFR: 41.10 / 43.5 / 45.13)
2.1.2 Knowledge of operator responsibilities during all modes of plant operation. 4.1 66
Subtotal                                                                                           3             2 Ability to explain the variations in control board/control room layouts, systems, 2.2.4                                                                                        3.6   69
: 1. (CFR: 41.10 / 45.13)
: 2.                           instrumentation, and procedural actions between units at a facility.
Conduct 2.1.14 Knowledge of criteria or conditions that require plant-wide announcements, 3.1 67 of Operations such as pump starts, reactor trips, mode changes, etc.
(CFR: 41.6, 7, 10 / 45.1, 13)
(CFR: 41.10 / 43.5 / 45.12) 2.1.7 Ability to evaluate plant performance and make operational judgements 4.4 68 based on operating characteristics, reactor behavior, and instrument interpretation.
Equipment                    Knowledge of the process for making changes to procedures.
(CFR: 41.7 / 43.5 / 45.4) 2.1.35 Knowledge of the fuel-handling responsibilities of SROs. 3.9 94 (CFR: 41.10 / 43.7) 2.1.39 Knowledge of conservative decision-making practices. 4.3 95 (CFR: 41.10 / 43.5 / 45.13)
Control              2.2.6                                                                                        3.0   70 (CFR: 41.10 / 43.3 / 45.13) 2.2.43   Knowledge of the process used to track inoperable alarms.                           3.0   71 (CFR: 41.10 / 43.5 / 45.13) 2.2.17   Knowledge of the process for managing maintenance activities during power                         3.8   96 operations, such as risk assessments, work prioritization, and coordination with the transmission system operator.
Subtotal 3 2 2.2.4 Ability to explain the variations in control board/control room layouts, systems, 3.6 69
(CFR: 41.10 / 43.5 / 45.13) 2.2.20   Knowledge of the process for managing troubleshooting activities.                                 3.8   97 (CFR: 41.10 / 43.5 / 45.13)
: 2. instrumentation, and procedural actions between units at a facility.
Subtotal                                                                                           3             2 2.3.5   Ability to use radiation monitoring systems, such as fixed radiation monitors       2.9   72
Equipment (CFR: 41.6, 7, 10 / 45.1, 13)
: 3.                           and alarms, portable survey instruments, personnel monitoring equipment, etc.
Control 2.2.6 Knowledge of the process for making changes to procedures. 3.0 70 (CFR: 41.10 / 43.3 / 45.13) 2.2.43 Knowledge of the process used to track inoperable alarms. 3.0 71 (CFR: 41.10 / 43.5 / 45.13) 2.2.17 Knowledge of the process for managing maintenance activities during power 3.8 96 operations, such as risk assessments, work prioritization, and coordination with the transmission system operator.
Radiation                    (CFR: 41.11, 12 / 43.4 / 45.9)
(CFR: 41.10 / 43.5 / 45.13) 2.2.20 Knowledge of the process for managing troubleshooting activities. 3.8 97 (CFR: 41.10 / 43.5 / 45.13)
Control                      Knowledge of radiological safety procedures pertaining to licensed operator 2.3.13                                                                                      3.4   73 duties, such as response to radiation monitor alarms, containment entry requirements, fuel handling responsibilities, access to locked high-radiation areas, aligning filters, etc.
Subtotal 3 2 2.3.5 Ability to use radiation monitoring systems, such as fixed radiation monitors 2.9 72
(CFR: 41.12 / 43.4 / 45.9, 10)
: 3. and alarms, portable survey instruments, personnel monitoring equipment, Radiation etc.
Ability to approve release permits.
Control (CFR: 41.11, 12 / 43.4 / 45.9) 2.3.13 Knowledge of radiological safety procedures pertaining to licensed operator 3.4 73 duties, such as response to radiation monitor alarms, containment entry requirements, fuel handling responsibilities, access to locked high-radiation areas, aligning filters, etc.
2.3.6                                                                                                      3.8   98 (CFR: 41.13 / 43.4 / 45.10)
(CFR: 41.12 / 43.4 / 45.9, 10) 2.3.6 Ability to approve release permits. 3.8 98 (CFR: 41.13 / 43.4 / 45.10)
Subtotal                                                                                           2             1 2.4.17   Knowledge of EOP terms and definitions.                                             3.9   74
Subtotal 2 1 2.4.17 Knowledge of EOP terms and definitions. 3.9 74
: 4.                           ((CFR: 41.10 / 45.13)
: 4. ((CFR: 41.10 / 45.13)
Knowledge of the operational implications of EOP warnings, cautions, and Emergency            2.4.20                                                                                      3.8   75 notes.
Emergency 2.4.20 Knowledge of the operational implications of EOP warnings, cautions, and 3.8 75 Procedures / notes.
Procedures /                  (CFR: 41.10 / 43.5 / 45.13)
Plan (CFR: 41.10 / 43.5 / 45.13) 2.4.23 Knowledge of the bases for prioritizing emergency procedure implementation 4.4 99 during emergency operations.
Plan                          Knowledge of the bases for prioritizing emergency procedure implementation 2.4.23                                                                                                      4.4   99 during emergency operations.
(CFR: 41.10 / 43.5 / 45.13) 2.4.44 Knowledge of emergency plant protective action recommendations. 4.4 100 (CFR: 41.10, 12 / 43.5 / 45.12)
(CFR: 41.10 / 43.5 / 45.13) 2.4.44   Knowledge of emergency plant protective action recommendations.                                   4.4   100 (CFR: 41.10, 12 / 43.5 / 45.12)
Subtotal 2 2
Subtotal                                                                                           2             2 Tier 3 Point Total                                                                                                       10             7}}
 
Tier 3 Point Total 10 7}}

Revision as of 02:03, 19 November 2024

ES-401-3
ML21361A257
Person / Time
Site: Byron  Constellation icon.png
Issue date: 10/28/2021
From: Gregory Roach
NRC/RGN-III/DRS/OLB
To:
Exelon Generation Co
Roach G
Shared Package
ML21055A846 List:
References
Download: ML21361A257 (1)


Text

ES-401 Generic Knowledge and Abilities Outline (Tier 3) Form ES-401-3

Facility: Byron Nuclear Generating Station Date of Exam: September 2021

Category K/A # Topic RO SRO-Only IR # IR #

2.1.2 Knowledge of operator responsibilities during all modes of plant operation. 4.1 66

1. (CFR: 41.10 / 45.13)

Conduct 2.1.14 Knowledge of criteria or conditions that require plant-wide announcements, 3.1 67 of Operations such as pump starts, reactor trips, mode changes, etc.

(CFR: 41.10 / 43.5 / 45.12) 2.1.7 Ability to evaluate plant performance and make operational judgements 4.4 68 based on operating characteristics, reactor behavior, and instrument interpretation.

(CFR: 41.7 / 43.5 / 45.4) 2.1.35 Knowledge of the fuel-handling responsibilities of SROs. 3.9 94 (CFR: 41.10 / 43.7) 2.1.39 Knowledge of conservative decision-making practices. 4.3 95 (CFR: 41.10 / 43.5 / 45.13)

Subtotal 3 2 2.2.4 Ability to explain the variations in control board/control room layouts, systems, 3.6 69

2. instrumentation, and procedural actions between units at a facility.

Equipment (CFR: 41.6, 7, 10 / 45.1, 13)

Control 2.2.6 Knowledge of the process for making changes to procedures. 3.0 70 (CFR: 41.10 / 43.3 / 45.13) 2.2.43 Knowledge of the process used to track inoperable alarms. 3.0 71 (CFR: 41.10 / 43.5 / 45.13) 2.2.17 Knowledge of the process for managing maintenance activities during power 3.8 96 operations, such as risk assessments, work prioritization, and coordination with the transmission system operator.

(CFR: 41.10 / 43.5 / 45.13) 2.2.20 Knowledge of the process for managing troubleshooting activities. 3.8 97 (CFR: 41.10 / 43.5 / 45.13)

Subtotal 3 2 2.3.5 Ability to use radiation monitoring systems, such as fixed radiation monitors 2.9 72

3. and alarms, portable survey instruments, personnel monitoring equipment, Radiation etc.

Control (CFR: 41.11, 12 / 43.4 / 45.9) 2.3.13 Knowledge of radiological safety procedures pertaining to licensed operator 3.4 73 duties, such as response to radiation monitor alarms, containment entry requirements, fuel handling responsibilities, access to locked high-radiation areas, aligning filters, etc.

(CFR: 41.12 / 43.4 / 45.9, 10) 2.3.6 Ability to approve release permits. 3.8 98 (CFR: 41.13 / 43.4 / 45.10)

Subtotal 2 1 2.4.17 Knowledge of EOP terms and definitions. 3.9 74

4. ((CFR: 41.10 / 45.13)

Emergency 2.4.20 Knowledge of the operational implications of EOP warnings, cautions, and 3.8 75 Procedures / notes.

Plan (CFR: 41.10 / 43.5 / 45.13) 2.4.23 Knowledge of the bases for prioritizing emergency procedure implementation 4.4 99 during emergency operations.

(CFR: 41.10 / 43.5 / 45.13) 2.4.44 Knowledge of emergency plant protective action recommendations. 4.4 100 (CFR: 41.10, 12 / 43.5 / 45.12)

Subtotal 2 2

Tier 3 Point Total 10 7