{{#Wiki_filter:Holtec Center, One Holtec Drive, Marlton, NJ 08053 Telephone (856) 797-0900 Fax (856) 797-0909 June 9, 2022 Pierre Saverot - Project Manager Storage and Transportation Licensing Branch Division of Fuel Management Office of Nuclear Material Safety and Safeguards ATTN: USNRC Document Control Desk U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 Docket No.: | {{#Wiki_filter:Holtec Center, One Holtec Drive, Marlton, NJ 08053 Telephone (856) 797-0900 Fax (856) 797-0909 | ||
June 9, 2022 | |||
Pierre Saverot - Project Manager Storage and Transportation Licensing Branch Division of Fuel Management Office of Nuclear Material Safety and Safeguards | |||
ATTN: USNRC Document Control Desk U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 | |||
Docket No.: 71-9375 | |||
==Subject:== | ==Subject:== | ||
| Line 28: | Line 36: | ||
==Dear Mr. Saverot,== | ==Dear Mr. Saverot,== | ||
By {{letter dated|date=May 10, 2022|text=letter dated May 10, 2022}} [1], Holtec re-submitted License Amendment Request (LAR) 9375-1 for the HI-STAR ATB 1T Certificate of Compliance (CoC) Number 9375. During subsequent discussion, it was determined that there were some errors in the submittal. Holtec apologizes for those errors and is submitting this modification to address those issues. The LAR submitted herewith shall be considered to supersede the previous LAR. | |||
The summary of proposed changes (SOPC) reiterating the proposed enhancement, including the reasons and justifications for the enhancement, is provided in Enclosure 1 to facilitate the Staffs review. | |||
The summary of proposed changes (SOPC) reiterating the proposed enhancement, including the reasons and justifications for the enhancement, is provided in Enclosure 1 to facilitate the Staffs review. contains Holtecs proposed changes to the Certificate of Compliance (CoC) for the Staffs convenience. | contains Holtecs proposed changes to the Certificate of Compliance (CoC) for the Staffs convenience. | ||
The updated SAR, HI-2146312 Proposed Revision 5, is provided with this LAR submittal. Note that all SAR text revised since HI-2146312 Revision 3 was reviewed and approved with CoC 9375-0 is highlighted in yellow, while changes specifically related to the addition of the proposed this amendment are indicated by revision bars in the right margin of the page, with red text identifying insertions and red strikethroughs identifying deletions. The SARs Revision Summary Log section includes information on the SARs revision status | |||
Doc. I.D.: 2404021-NRC | The updated SAR, HI-2146312 Proposed Revision 5, is provided with this LAR submittal. Note that all SAR text revised since HI-2146312 Revision 3 was reviewed and approved with CoC 9375-0 is highlighted in yellow, while changes specifically related to the addition of the proposed this amendment are indicated by revision bars in the right margin of the page, with red text identifying insertions and red strikethroughs identifying deletions. The SARs Revision Summary Log section includes information on the SARs revision status a nd configuration control. | ||
Doc. I.D.: 2404021-NRC When separated from the enclosures, this cover letter is non-proprietary. | |||
Page 1 of 3 | Page 1 of 3 | ||
Holtec Center, One Holtec Drive, Marlton, NJ 08053 Telephone (856) 797-0900 Fax (856) 797-0909 Proprietary and non-proprietary | Holtec Center, One Holtec Drive, Marlton, NJ 08053 Telephone (856) 797-0900 Fax (856) 797-0909 | ||
Enclosures 6 through 8 contain | |||
As Enclosures 1, 3, 5, 6, 7, & 8 are considered proprietary, an affidavit requesting that the information therein be withheld from public disclosure in | Proprietary and non-proprietary ve rsions of the SAR are submitted herewith as Enclosures 3 and 4, respectively. | ||
If you have any questions, please contact me at 856-797-0900 | contains the drawings that comprise the licensing drawing package. | ||
Enclosures 6 through 8 contain th e supporting calculation packa ges. | |||
As Enclosures 1, 3, 5, 6, 7, & 8 are considered proprietary, an affidavit requesting that the information therein be withheld from public disclosure in accor dance with 10 CFR 2.390 is contained in Enclosure 9. | |||
If you have any questions, please contact me at 856-797-0900 ex t 3951 | |||
Sincerely, | |||
Kimberly Manzione Director of Licensing - NMSS Projects Holtec International | |||
cc: (letter only w/o a ttachments via email) | |||
Shana Helton (USNRC) | Shana Helton (USNRC) | ||
Doc. I.D.: 2404021-NRC | |||
Doc. I.D.: 2404021-NRC When separated from the enclosures, this cover letter is non-proprietary. | |||
Page 2 of 3 | Page 2 of 3 | ||
Holtec Center, One Holtec Drive, Marlton, NJ 08053 Telephone (856) 797-0900 Fax (856) 797-0909 Enclosures : | Holtec Center, One Holtec Drive, Marlton, NJ 08053 Telephone (856) 797-0900 Fax (856) 797-0909 | ||
BFA-Tanks and Cassettes Licensing Drawing No. 9876, Rev. 9 (PROPRIETARY) : | |||
Enclosures | |||
: Summary of Proposed Changes (SOPC) for HI-STAR ATB 1T LAR 9375-1 (PROPRIETARY) : Holtec Proposed CoC 71-9375 Revision 1 for the HI-STAR ATB 1T Non-Fuel Waste Transport System (NON-PROPRIETARY) : Holtec Report HI-2146312, Safety Analysis Report on the HI-STAR ATB 1T Non-Fuel Waste Transport System, Proposed Revision 5 (PROPRIETARY) : Holtec Report HI-2146312, Safety Analysis Report on the HI-STAR ATB 1T Non-Fuel Waste Transport System, Proposed Revision 5 (NON-PROPRIETARY) : HI-STAR ATB 1T Cask Licensing Drawing No. 9786, Rev. 9 (PROPRIETARY) | |||
BFA-Tanks and Cassettes Licensing Drawing No. 9876, Rev. 9 (PROPRIETARY) : Holtec Report HI-2177539, Drop Analysis of the HI-STAR ATB 1T Transport Package, Proposed Revision 7 (PROPRIETARY) : Holtec Report HI-2177540, Structural Calculation Package for HI-STAR ATB 1T Transport Package, Proposed Revision 6 (PROPRIETARY) : Holtec Report HI-2156585, Thermal Evaluation of HI-STAR ATB 1T Cask, Proposed Revision 5 (PROPRIETARY) : Affidavit in Accordance with 10 CFR 2.390 | |||
Doc. I.D.: 2404021-NRC When separated from the enclosures, this cover letter is non-proprietary. | |||
Page 3 of 3}} | Page 3 of 3}} | ||
Revision as of 20:10, 17 November 2024
| ML22161A059 | |
| Person / Time | |
|---|---|
| Site: | 07109375 |
| Issue date: | 06/09/2022 |
| From: | Manzione K Holtec |
| To: | Pierre Saverot Document Control Desk, Office of Nuclear Material Safety and Safeguards |
| Shared Package | |
| ML22161A058 | List: |
| References | |
| 2404021 | |
| Download: ML22161A059 (3) | |
Text
Holtec Center, One Holtec Drive, Marlton, NJ 08053 Telephone (856) 797-0900 Fax (856) 797-0909
June 9, 2022
Pierre Saverot - Project Manager Storage and Transportation Licensing Branch Division of Fuel Management Office of Nuclear Material Safety and Safeguards
ATTN: USNRC Document Control Desk U.S. Nuclear Regulatory Commission Washington, DC 20555-0001
Docket No.: 71-9375
Subject:
Modification of License Amendment Request 9375-1 for the HI-STAR ATB 1T Non-Fuel Waste Transport System
Reference:
[1] Re-Submittal of License Amendment Request 9375-1 for the HI-STAR ATB 1T Non-Fuel Waste Transport System, Holtec Letter 2404020-NRC from Christopher OMullane (Holtec) to Pierre Saverot (NRC), dated May 10, 2022.
Dear Mr. Saverot,
By letter dated May 10, 2022 [1], Holtec re-submitted License Amendment Request (LAR) 9375-1 for the HI-STAR ATB 1T Certificate of Compliance (CoC) Number 9375. During subsequent discussion, it was determined that there were some errors in the submittal. Holtec apologizes for those errors and is submitting this modification to address those issues. The LAR submitted herewith shall be considered to supersede the previous LAR.
The summary of proposed changes (SOPC) reiterating the proposed enhancement, including the reasons and justifications for the enhancement, is provided in Enclosure 1 to facilitate the Staffs review.
contains Holtecs proposed changes to the Certificate of Compliance (CoC) for the Staffs convenience.
The updated SAR, HI-2146312 Proposed Revision 5, is provided with this LAR submittal. Note that all SAR text revised since HI-2146312 Revision 3 was reviewed and approved with CoC 9375-0 is highlighted in yellow, while changes specifically related to the addition of the proposed this amendment are indicated by revision bars in the right margin of the page, with red text identifying insertions and red strikethroughs identifying deletions. The SARs Revision Summary Log section includes information on the SARs revision status a nd configuration control.
Doc. I.D.: 2404021-NRC When separated from the enclosures, this cover letter is non-proprietary.
Page 1 of 3
Holtec Center, One Holtec Drive, Marlton, NJ 08053 Telephone (856) 797-0900 Fax (856) 797-0909
Proprietary and non-proprietary ve rsions of the SAR are submitted herewith as Enclosures 3 and 4, respectively.
contains the drawings that comprise the licensing drawing package.
Enclosures 6 through 8 contain th e supporting calculation packa ges.
As Enclosures 1, 3, 5, 6, 7, & 8 are considered proprietary, an affidavit requesting that the information therein be withheld from public disclosure in accor dance with 10 CFR 2.390 is contained in Enclosure 9.
If you have any questions, please contact me at 856-797-0900 ex t 3951
Sincerely,
Kimberly Manzione Director of Licensing - NMSS Projects Holtec International
cc: (letter only w/o a ttachments via email)
Doc. I.D.: 2404021-NRC When separated from the enclosures, this cover letter is non-proprietary.
Page 2 of 3
Holtec Center, One Holtec Drive, Marlton, NJ 08053 Telephone (856) 797-0900 Fax (856) 797-0909
Enclosures
- Summary of Proposed Changes (SOPC) for HI-STAR ATB 1T LAR 9375-1 (PROPRIETARY) : Holtec Proposed CoC 71-9375 Revision 1 for the HI-STAR ATB 1T Non-Fuel Waste Transport System (NON-PROPRIETARY) : Holtec Report HI-2146312, Safety Analysis Report on the HI-STAR ATB 1T Non-Fuel Waste Transport System, Proposed Revision 5 (PROPRIETARY) : Holtec Report HI-2146312, Safety Analysis Report on the HI-STAR ATB 1T Non-Fuel Waste Transport System, Proposed Revision 5 (NON-PROPRIETARY) : HI-STAR ATB 1T Cask Licensing Drawing No. 9786, Rev. 9 (PROPRIETARY)
BFA-Tanks and Cassettes Licensing Drawing No. 9876, Rev. 9 (PROPRIETARY) : Holtec Report HI-2177539, Drop Analysis of the HI-STAR ATB 1T Transport Package, Proposed Revision 7 (PROPRIETARY) : Holtec Report HI-2177540, Structural Calculation Package for HI-STAR ATB 1T Transport Package, Proposed Revision 6 (PROPRIETARY) : Holtec Report HI-2156585, Thermal Evaluation of HI-STAR ATB 1T Cask, Proposed Revision 5 (PROPRIETARY) : Affidavit in Accordance with 10 CFR 2.390
Doc. I.D.: 2404021-NRC When separated from the enclosures, this cover letter is non-proprietary.
Page 3 of 3