ML17228A048: Difference between revisions
Jump to navigation
Jump to search
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
||
| Line 2: | Line 2: | ||
| number = ML17228A048 | | number = ML17228A048 | ||
| issue date = 08/14/2017 | | issue date = 08/14/2017 | ||
| title = Final 10 CFR Part 21.21 Report | | title = Final 10 CFR Part 21.21 Report Re Defect of Manual Flow Controller Used at Fort Calhoun Nuclear Station | ||
| author name = Webb S | | author name = Webb S | ||
| author affiliation = Mirion Technologies (Canberra), Inc | | author affiliation = Mirion Technologies (Canberra), Inc | ||
| Line 12: | Line 12: | ||
| document type = Deficiency Correspondence (per 10CFR50.55e and Part 21), Deficiency Report (per 10CFR50.55e and Part 21) | | document type = Deficiency Correspondence (per 10CFR50.55e and Part 21), Deficiency Report (per 10CFR50.55e and Part 21) | ||
| page count = 2 | | page count = 2 | ||
| revision = 0 | |||
}} | }} | ||
Revision as of 07:57, 24 February 2018
| ML17228A048 | |
| Person / Time | |
|---|---|
| Site: | Fort Calhoun |
| Issue date: | 08/14/2017 |
| Revision: | 0 |
| From: | Webb S Mirion Technologies (Canberra) |
| To: | Document Control Desk, Office of Nuclear Reactor Regulation |
| References | |
| Download: ML17228A048 (2) | |