ML17347A110: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
(StriderTol Bot change)
 
Line 6: Line 6:
| number = ML17352A014
| number = ML17352A014
| issue date = 01/16/2018
| issue date = 01/16/2018
| title = Request for Additional Information Westinghouse Electric Company WCAP-18032-P, Revision 0 and WCAP-18032-NP, Revision 0, Calculation of Mixed Core Safety Limit Minimum Critical Power Ratio Topical Report
| title = Request for Additional Information Westinghouse Electric Company WCAP-18032-P, Revision 0 and WCAP-18032-NP, Revision 0, Calculation of Mixed Core Safety Limit Minimum Critical Power Ratio Topical Report (Enclosure 1/Non-Prop)
| author name = Lenning E
| author name = Lenning E
| author affiliation = NRC/NRR/DLP/PLPB
| author affiliation = NRC/NRR/DLP/PLPB

Latest revision as of 20:33, 6 March 2020

Request for Additional Information Westinghouse Electric Company WCAP-18032-P, Revision 0 and WCAP-18032-NP, Revision 0, Calculation of Mixed Core Safety Limit Minimum Critical Power Ratio Topical Report
Date released: 01/17/2018 Download: ML17347A110



Request for Additional Information Westinghouse Electric Company WCAP-18032-P, Revision 0 and WCAP-18032-NP, Revision 0, Calculation of Mixed Core Safety Limit Minimum Critical Power Ratio Topical Report (Enclosure 1/Non-Prop)
ML17352A014
Person / Time
Site: Westinghouse
Issue date: 01/16/2018
From: Ekaterina Lenning
NRC/NRR/DLP/PLPB
To:
Westinghouse
Lenning E
References
TAC MF9017, WCAP-18032-NP, WCAP-18032-P
Download: ML17352A014 (4)
Request for Additional Information Westinghouse Electric Company WCAP-18032-P, Revision 0 and WCAP-18032-NP, Revision 0, Calculation of Mixed Core Safety Limit Minimum Critical Power Ratio Topical Report
ML17352A013
Person / Time
Site: Westinghouse
Issue date: 01/16/2018
From: Ekaterina Lenning
NRC/NRR/DLP/PLPB
To: Gresham J A
Westinghouse
Lenning E
References
TAC MF9017, WCAP-18032-NP, WCAP-18032-P
Download: ML17352A013 (2)