ML18024A841: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
 
(StriderTol Bot change)
 
(One intermediate revision by the same user not shown)
Line 6: Line 6:
| number = ML18024A842
| number = ML18024A842
| issue date = 06/06/1979
| issue date = 06/06/1979
| title = Forwards LER 79-009/03L-0
| title = LER 79-009/03L-0 on 790510:scram Accumulator Level Switch LS-2-85-34 for Control Rod Drivelines 58-39 & 58-19 Failed to Give Annunciation for High Accumulator Level.Caused by Switch Failure
| author name =  
| author name =  
| author affiliation = TENNESSEE VALLEY AUTHORITY
| author affiliation = TENNESSEE VALLEY AUTHORITY
Line 22: Line 22:
| issue date = 06/06/1979
| issue date = 06/06/1979
| title = Forwards LER 79-009/03L-0
| title = Forwards LER 79-009/03L-0
| author name = FOX H S
| author name = Fox H
| author affiliation = TENNESSEE VALLEY AUTHORITY
| author affiliation = TENNESSEE VALLEY AUTHORITY
| addressee name = OREILLY J P
| addressee name = OREILLY J P

Latest revision as of 12:29, 6 March 2020

Forwards LER 79-009/03L-0
Date released: 09/27/2018 Download: ML18024A841


LER 79-009/03L-0 on 790510:scram Accumulator Level Switch LS-2-85-34 for Control Rod Drivelines 58-39 & 58-19 Failed to Give Annunciation for High Accumulator Level.Caused by Switch Failure
ML18024A842
Person / Time
Site: Browns Ferry Tennessee Valley Authority icon.png
Issue date: 06/06/1979
From:
TENNESSEE VALLEY AUTHORITY
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML18024A842 (4)
Forwards LER 79-009/03L-0
ML18024A840
Person / Time
Site: Browns Ferry Tennessee Valley Authority icon.png
Issue date: 06/06/1979
From: Fox H
TENNESSEE VALLEY AUTHORITY
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML18024A840 (2)