{{#Wiki_filter: | {{#Wiki_filter:UNITED STATES NUCLEAR REGULATORY COMMISSION REGION III 2443 WARRENVILLE ROAD, SUITE 210 LISLE, IL 60532-4352 | ||
June 3, 2013 | |||
BRAIDWOOD STATION, UNITS 1 AND 2 NRC SECURITY BASELINE INSPECTION REPORT 05000456/2013404; 05000457/2013404 | |||
Mr. Michael Senior Vice President, Exelon Generation Company, LLC President and Chief Nuclear Officer, Exelon Nuclear 4300 Winfield Road Warrenville, IL 60555 SUBJECT: BRAIDWOOD STATION, UNITS 1 AND 2 NRC SECURITY BASELINE INSPECTION REPORT 05000456/2013404; 05000457/2013404 | |||
==Dear Mr. Pacilio:== | ==Dear Mr. Pacilio:== | ||
Revision as of 04:44, 15 July 2019
| ML13155A470 | |
| Person / Time | |
|---|---|
| Site: | Braidwood |
| Issue date: | 06/03/2013 |
| From: | Maynen J Plant Support Branch II |
| To: | Pacilio M Exelon Generation Co, Exelon Nuclear |
| References | |
| IR-13-404 | |
| Download: ML13155A470 (3) | |
Text
UNITED STATES NUCLEAR REGULATORY COMMISSION REGION III 2443 WARRENVILLE ROAD, SUITE 210 LISLE, IL 60532-4352
June 3, 2013
Mr. Michael Senior Vice President, Exelon Generation Company, LLC President and Chief Nuclear Officer, Exelon Nuclear 4300 Winfield Road Warrenville, IL 60555 SUBJECT: BRAIDWOOD STATION, UNITS 1 AND 2 NRC SECURITY BASELINE INSPECTION REPORT 05000456/2013404; 05000457/2013404
Dear Mr. Pacilio:
On April 26, 2013, the U.S. Nuclear Regulatory Commission (NRC) completed an inspection at your Braidwood Station, Units 1 and 2. The inspection covered one or more of the key attributes of the security cornerstone of the NRC's Reactor Oversight Process. The enclosed inspection report documents the inspection results, which were discussed on April 26, 2013, with Mr. D. Enright and other members of your staff. The inspection examined activities conducted under your license as they relate to security and compliance with the Commission's rules and regulations and with the conditions of your license. The inspectors reviewed selected procedures and records, observed activities, and interviewed personnel. No findings were identified during this inspection.
In accordance with 10 CFR 2.390 of the NRC's "Rules of Practice," a copy of this letter will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records System (PARS) component of NRC's Agencywide Documents Access and Management System (ADAMS). ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room). However, the material enclosed herewith contains Security-Related Information in accordance with 10 CFR 2.390(d)(1) and its disclosure to unauthorized individuals could present a security vulnerability. Therefore, the material in the enclosure will not be made available electronically for public inspection in the NRC Public Document Room or from the PARS component of NRC's ADAMS.
Enclosure contains Sensitive Unclassified Non-Safeguards Information. When separated from enclosure, this transmittal document is decontrolled. If you choose to provide a response and Security-Related Information is necessary to provide an acceptable response, please mark your entire response "Security-Related Information - Withhold from public disclosure under 10 CFR 2.390" in accordance with 10 CFR 2.390(d)(1)
and follow the instructions for withholding in 10 CFR 2.390 (b)(1). In accordance with 10 CFR 2.390(b)(1)(ii), the NRC is waiving the a ffidavit requirements for your response. Should you have any questions concerning this inspection, we will be pleased to discuss them with you.
Sincerely,
/RA/ Joseph D. Maynen, Acting Chief
Plant Support Branch
Division of Reactor Safety
Docket Nos. 50-456; 50-457 License Nos. NPF-72; NPF-77
Nonpublic Enclosure: Inspection Report 05000456/2013404; 05000457/2013404 w/Attachment: Supplemental Information
cc w/encl: S. Coker, NSIR/DSO/DDSO/ST R. Albert, NSIR
T. Dimitriadis, RI
B. Desai, RII M. Haire, RIV B. Finlay, Braidwood Station Security Manager J. Klinger, State Liaison Officer, Illinois Emergency Management Agency
cc w/o encl: Distribution via ListServŽ