Line 3: Line 3:
| issue date = 12/04/2006
| issue date = 12/04/2006
| title = G20060793 - John D. Runkle, Esq., 2.206 Petition Acknowledgment Letter Fire Protection Violations at the Shearon Harris Nuclear Power Plant, Unit 1
| title = G20060793 - John D. Runkle, Esq., 2.206 Petition Acknowledgment Letter Fire Protection Violations at the Shearon Harris Nuclear Power Plant, Unit 1
| author name = Dyer J E
| author name = Dyer J
| author affiliation = NRC/NRR
| author affiliation = NRC/NRR
| addressee name = Runkle J D
| addressee name = Runkle J
| addressee affiliation = - No Known Affiliation
| addressee affiliation = - No Known Affiliation
| docket = 05000400
| docket = 05000400

Revision as of 08:43, 13 July 2019

G20060793 - John D. Runkle, Esq., 2.206 Petition Acknowledgment Letter Fire Protection Violations at the Shearon Harris Nuclear Power Plant, Unit 1
ML063210413
Person / Time
Site: Harris Duke Energy icon.png
Issue date: 12/04/2006
From: Dyer J
Office of Nuclear Reactor Regulation
To: Runkle J
- No Known Affiliation
REGNER, Lisa, DORL/LPL2-2, 415-1906
Shared Package
ML062900551 List:
References
2.206 Petition, G20060793, TAC MD3039
Download: ML063210413 (5)


Text

December 4, 2006John D. RunkleAttorney at Law P.O. Box 3793 Chapel Hill, NC 27515

Dear Mr. Runkle:

Your petition dated September 20, 2006, addressed to Luis A. Reyes, Executive Director forOperations at the Nuclear Regulatory Commission (NRC), and filed on behalf of numerous petitioners, has been referred to me pursuant to Title 10 of the Code of Federal Regulations (10 CFR), Section 2.206. You request that the NRC immediately issue an Order suspending the Shearon Harris Nuclear Power Plant (SHNPP) operating license until SHNPP is in compliance with fire safety regulations. As the basis for your request, you discuss several fire safety violations at SHNPP which could affect the safe operation of the plant and safe shutdown of the plant in emergency situations. I would like to express my appreciation for your effort in bringing these matters to the attention of the NRC.The Petition Review Board (PRB) met on October 10, 2006, to discuss your request forimmmediate action to revoke SHNPP's operating license. The PRB denied your request for immediate action based on the staff's determination that there was no immediate threat to public health and safety. You were notified of this by phone on October 17, 2006.In a public meeting at NRC Headquarters on November 13, 2006, you met with the PRB topresent additional relevant information concerning your petition. The supplemental documents dated October 23 and 30, 2006, and submitted on October 23 and November 13, 2006, have been entered into the NRC's Agencywide Documents Access and Management System (ADAMS) under accession numbers ML062980107 and ML063200168, respectively. The results of that discussion and the supplemental documents have been considered in the PRB'sdetermination regarding your petition and in establishing the schedule for the review of your petition.After considering the petition request, and information provided at the public meeting, the PRBhas determined that your request does meet the criteria for acceptance as a 10 CFR 2.206 petition.

J. Runkle- 2 -As provided by Section 2.206, we will take action on your request within a reasonable time.Chandu Patel will be taking over as petition manager for your petition. Mr. Patel can be reached at 301-415-3025. Your petition is being reviewed by the Fire Protection Branch in the Office of Nuclear Reactor Regulation. I have referred to the NRC Office of the Inspector General (OIG) those allegations of NRC wrongdoing contained in your petition. I have enclosedfor your information a copy of the notice that is being filed with the Office of the Federal Register for publication. I have also enclosed for your information a copy of Management Directive 8.11, "Review Process for 10 CFR 2.206 Petitions," and the associated brochure NUREG/BR-0200, "Public Petition Process," prepared by the NRC Office of Public Affairs. Sincerely,/RA/J. E. Dyer, DirectorOffice of Nuclear Reactor RegulationDocket No. 50-400

Enclosures:

1. Federal Register Notice2. Management Directive 8.11
3. NUREG/BR-0200cc w/encls: See next page

Letter: ML063210413Package: ML062900551 Federal Register Notice: ML063210449Incoming: ML062640550 MD 8.11: ML011380727 NUREG/BR-0200: ML013600445OFFICENRR/LPL2-2/PMNRR/LPL2-2/PMNRR/LPL2-2/LANRR/LPL2-2/BCNAMELRegnerCPatelCSolaMargaret Chernoff forDPickettDATE 11 / 28 /06 11 / 30 /06 11 / 28 /0611 / 29 /06 OFFICENRR/DPR/DDNRR/DORL/DNRR/D NAMEMichael Case for HNiehCHaneyJDyerDATE 11/29/06 11/30/06 12/04/06

cc w/copy of incoming 2.206 request:Mr. Cornelius J. Gannon, Vice President Shearon Harris Nuclear Power Plant Carolina Power & Light Company Post Office Box 165, Mail Code: Zone 1 New Hill, North Carolina 27562-0165 cc:David T. Conley Associate General Counsel II -

Legal Department Progress Energy Service Company, LLC Post Office Box 1551 Raleigh, North Carolina 27602-1551Resident Inspector/ Harris NPSc/o U. S. Nuclear Regulatory Commission 5421 Shearon Harris Road New Hill, North Carolina 27562-9998Ms. Margaret A. ForceAssistant Attorney General State of North Carolina Post Office Box 629 Raleigh, North Carolina 27602Public Service CommissionState of South Carolina Post Office Drawer 11649 Columbia, South Carolina 29211Ms. Beverly Hall, Section ChiefDivision of Radiation Protection N.C. Department of Environment and Natural Resources 3825 Barrett Drive Raleigh, North Carolina 27609-7721Mr. Chris L. BurtonManager Performance Evaluation and Regulatory Affairs PEB 7 Progress Energy Post Office Box 1551 Raleigh, North Carolina 27602-1551Mr. Eric McCartneyPlant General Manager Shearon Harris Nuclear Power Plant Carolina Power & Light Company P. O. Box 165, Mail Zone 3 New Hill, North Carolina 27562-0165Mr. Robert J. Duncan IIDirector of Site Operations Shearon Harris Nuclear Power Plant Carolina Power & Light Company Post Office Box 165, Mail Zone 1 New Hill, North Carolina 27562-0165Mr. Robert P. GruberExecutive Director Public Staff NCUC 4326 Mail Service Center Raleigh, North Carolina 27699-4326Chairman of the North Carolina Utilities Commission Post Office Box 29510 Raleigh, North Carolina 27626-0510Mr. Herb Council, ChairBoard of County Commissioners of Wake County P. O. Box 550 Raleigh, North Carolina 27602Mr. Tommy Emerson, ChairBoard of County Commissioners of Chatham County P. O. Box 87 Pittsboro, North Carolina 27312Mr. Christos Kamilaris, ManagerSupport Services Shearon Harris Nuclear Power Plant Carolina Power & Light Company P. O. Box 165, Mail Zone 1 New Hill, North Carolina 27562-0165Mr. David H. Corlett, SupervisorLicensing/Regulatory Programs Shearon Harris Nuclear Power Plant Carolina Power & Light Company P. O. Box 165, Mail Zone 1 New Hill, NC 27562-0165Mr. John H. O'Neill, Jr.Shaw, Pittman, Potts & Trowbridge 2300 N Street, NW.

Washington, DC 20037-1128 cc:Mr. James Warren N.C. Waste Awareness & Reduction Network P.O. Box 61051 Durham, NC 27715-1051Mr. Paul GunterNuclear Info & Resource Services 6930 Carroll Ave., Suite 340 Takoma Park, MD 20912Mr. David LochbaumUnion of Concerned Scientists 1707 H. St. N.W., Suite 600 Washington, DC 20006-3962NC Fair Share3824 Barrett Dr., Suite 312 Raleigh, NC 27609 Students United for a Responsible Global Environment P.O. Box 1188 Chapel Hill, NC 27514Ms. Sabrina M. OliverTown of Chapel Hill 405 Martin Luther King, Jr. Blvd.

Chapel Hill, NC 27514-5705Mr. Mark Chilton, MayorTown of Carrboro 301 W. Main St.

Carrboro, NC 27510Ms. Donna S. BakerOrange County Board of Commissioners P.O. Box 8181 200 South Cameron Street Hillsborough, NC 27278