IR 05000331/2009405: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
(Created page by program invented by StriderTol)
Line 3: Line 3:
| issue date = 11/17/2009
| issue date = 11/17/2009
| title = IR 05000331-09-405, (Drs), on 10/05/2009 - 10/08/2009, for Duane Arnold
| title = IR 05000331-09-405, (Drs), on 10/05/2009 - 10/08/2009, for Duane Arnold
| author name = Duncan E R
| author name = Duncan E
| author affiliation = NRC/RGN-III/DRS/PSB
| author affiliation = NRC/RGN-III/DRS/PSB
| addressee name = Costanzo C R
| addressee name = Costanzo C
| addressee affiliation = NextEra Energy Duane Arnold, LLC
| addressee affiliation = NextEra Energy Duane Arnold, LLC
| docket = 05000331
| docket = 05000331
Line 18: Line 18:


=Text=
=Text=
{{#Wiki_filter:UNITED STATES NUCLEAR REGULATORY COMMISSION REGION III 2443 WARRENVILLE ROAD, SUITE 210 LISLE, IL 60532-4352 November 17, 2009 Mr. Christopher Vice President Duane Arnold Energy Center 3277 DAEC Road
{{#Wiki_filter:ber 17, 2009


Palo, IA 52324-9785
==SUBJECT:==
 
DUANE ARNOLD ENERGY CENTER NRC SECURITY BASELINE INSPECTION REPORT 05000331/2009405(DRS)
SUBJECT: DUANE ARNOLD ENERGY CENTER NRC SECURITY BASELINE INSPECTION REPORT 05000331/2009405(DRS)


==Dear Mr. Costanzo:==
==Dear Mr. Costanzo:==
Line 41: Line 40:
Enclosure contains Sensitive Unclassified Non-Safeguards Information. When separated from enclosure, this transmittal document is decontrolled. - SECURITY-RELATED INFO RMATION Should you have any questions concerning this inspection, we will be pleased to discuss them with you.
Enclosure contains Sensitive Unclassified Non-Safeguards Information. When separated from enclosure, this transmittal document is decontrolled. - SECURITY-RELATED INFO RMATION Should you have any questions concerning this inspection, we will be pleased to discuss them with you.


Sincerely,/RA/
Sincerely,
/RA/
Eric Duncan, Chief  
Eric Duncan, Chief  


Plant Support Branch Division of Reactor Safety Docket No. 50-331 License No. DPR-49  
Plant Support Branch Division of Reactor Safety Docket No. 50-331 License No. DPR-49  


Nonpublic  
Nonpublic Enclosure: Inspection Report 05000331/2009405(DRS) w/Attachment: Supplemental Information  
 
===Enclosure:===
Inspection Report 05000331/2009405(DRS)  
 
===w/Attachment:===
Supplemental Information  


cc w/encl: S. Coker, NSIR/DSO/DDSO/ST M. Nazar, Senior Vice President & Chief Nuclear Officer M. Rasmusson, State Liaison Officer, State of Iowa  
cc w/encl: S. Coker, NSIR/DSO/DDSO/ST M. Nazar, Senior Vice President & Chief Nuclear Officer M. Rasmusson, State Liaison Officer, State of Iowa  

Revision as of 15:26, 11 July 2019

IR 05000331-09-405, (Drs), on 10/05/2009 - 10/08/2009, for Duane Arnold
ML093240519
Person / Time
Site: Duane Arnold NextEra Energy icon.png
Issue date: 11/17/2009
From: Eric Duncan
Plant Support Branch II
To: Costanzo C
NextEra Energy Duane Arnold
References
IR-09-405
Download: ML093240519 (3)


Text

ber 17, 2009

SUBJECT:

DUANE ARNOLD ENERGY CENTER NRC SECURITY BASELINE INSPECTION REPORT 05000331/2009405(DRS)

Dear Mr. Costanzo:

On October 8, 2009, the U. S. Nuclear Regulatory Commission (NRC) completed a security baseline inspection at your Duane Arnold Energy Center. The inspection covered one or more of the key attributes of the security cornerstone of the NRC's Reactor Oversight Process. The enclosed inspection report documents the inspection results, which were discussed on October 8, 2009, with Mr. Byrne and other members of your staff.

The inspection examined activities conducted under your license as they relate to security and compliance with the Commission's rules and regulations and with the conditions of your license.

The inspectors reviewed selected procedures and records, observed activities, and interviewed

personnel.

No findings of significance were identified.

In accordance with 10 CFR 2.390 of the NRC's "Rules of Practice," a copy of this letter will be

available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records System (PARS) component of NRC's Agencywide Documents Access and Management System (ADAMS), accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room). However, because of the security-related concerns contained in the enclosures, and in accordance with 10 CFR 2.390, a copy of this letter's enclosure will not be available for public inspection.

Enclosure contains Sensitive Unclassified Non-Safeguards Information. When separated from enclosure, this transmittal document is decontrolled. - SECURITY-RELATED INFO RMATION Should you have any questions concerning this inspection, we will be pleased to discuss them with you.

Sincerely,

/RA/

Eric Duncan, Chief

Plant Support Branch Division of Reactor Safety Docket No. 50-331 License No. DPR-49

Nonpublic Enclosure: Inspection Report 05000331/2009405(DRS) w/Attachment: Supplemental Information

cc w/encl: S. Coker, NSIR/DSO/DDSO/ST M. Nazar, Senior Vice President & Chief Nuclear Officer M. Rasmusson, State Liaison Officer, State of Iowa

cc w/o encl: Distribution via ListServ