ML080380433: Difference between revisions
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
||
| Line 2: | Line 2: | ||
| number = ML080380433 | | number = ML080380433 | ||
| issue date = 02/12/2008 | | issue date = 02/12/2008 | ||
| title = | | title = Request for Additional Information License Amendment Request to Modify TS 6.9.1.11.1, Core Operating Limits, TS 3.5.1, Safety Injection Tanks, & TS 3.6.1.5, Containment Air Temperature to Support Next Generation Fuel | ||
| author name = Kalyanam N K | | author name = Kalyanam N K | ||
| author affiliation = NRC/NRR/ADRO/DORL/LPLIV | | author affiliation = NRC/NRR/ADRO/DORL/LPLIV | ||
Revision as of 04:30, 10 February 2019
| ML080380433 | |
| Person / Time | |
|---|---|
| Site: | Waterford |
| Issue date: | 02/12/2008 |
| From: | Kalyanam N K NRC/NRR/ADRO/DORL/LPLIV |
| To: | Walsh K T Entergy Operations |
| Kalyanam N, NRR/DORL/LPL4, 415-1480 | |
| References | |
| TAC MD6299 | |
| Download: ML080380433 (4) | |
Text
February 12, 2008
Mr. Kevin T. Walsh Vice President of Operations Entergy Operations, Inc.
17265 River Road Killona, LA 70057-3093
SUBJECT:
WATERFORD STEAM ELECTRIC STATION, UNIT 3 - REQUEST FOR ADDITIONAL INFORMATION ON LICENSE AMENDMENT REQUEST (LAR) NPF-38-271 TO SUPPORT NEXT GENERATION FUEL (TAC NO. MD6299)
Dear Mr. Walsh:
By letter dated August 2, 2007, Entergy Operations, Inc., submitted an application requesting an amendment to Waterford Steam Electric Station, Unit 3 Technical Specifications (TS) 6.9.1.11.1, Core Operating Limits, TS 3.5.1, Safety Injection Tanks, and TS 3.6.1.5, Containment Air Temperature.
After reviewing your request, the Nuclear Regulatory Commission staff has determined that additional information outlined in the enclosure is needed to complete the review. Please provide the additional information requested within 30 days of the receipt of this letter.
If you have any questions, please contact me at (301) 415-1480.
Sincerely,
/RA/
N. Kalyanam, Project Manager Plant Licensing Branch IV Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation
Docket No. 50-382 Enclosure
cc w/encl: See next page
ML080380433 *No major change from Staff provided RAI OFFICE NRR/LPL4/PM NRR/LPL4/LA NRR/DSS/SRXB* NRR/LPL4/BC NAME NKalyanam JBurkhardt GCranston THiltz DATE 2/11/08 2/11/08 1/31/08 2/12/08 Waterford Steam Electric Station, Unit 3 (November 2007)
cc: Senior Vice President Entergy Nuclear Operations P.O. Box 31995 Jackson, MS 39286-1995
Senior Vice President and COO Entergy Operations, Inc. P.O. Box 31995 Jackson, MS 39286-1995
Vice President, Operations Support Entergy Services, Inc. P.O. Box 31995 Jackson, MS 39286-1995 Site Vice President Waterford Steam Electric Station, Unit 3 Entergy Operations, Inc.
17265 River Road Killona, LA 70057-3093
General Manager, Plant Operations Waterford Steam Electric Station, Unit 3 Entergy Operations, Inc.
17265 River Road Killona, LA 70057-3093
Director, Nuclear Safety & Licensing Entergy Services, Inc.
440 Hamilton Avenue
White Plains, NY 10601
Director, Nuclear Safety Assurance Entergy Operations, Inc.
17265 River Road Killona, LA 70057-3093
Senior Manager, Nuclear Safety & Licensing Entergy Services, Inc.
P.O. Box 31995 Jackson, MS 39286-1995
Manager, Licensing Entergy Operations, Inc.
17265 River Road Killona, LA 70057-3093 Mr. Timothy Pflieger Environmental Scientist - Supervisor REP&R-CAP-SPOC Louisiana Department of Environmental
Quality P.O. Box 4312 Baton Rouge, LA 70821-4312
Parish President Council
St. Charles Parish P.O. Box 302 Hahnville, LA 70057 Chairman Louisiana Public Services Commission P.O. Box 91154 Baton Rouge, LA 70825-1697
Mr. Richard Penrod, Senior Environmental Scientist/State Liaison Officer Office of Environmental Services
Northwestern State University Russell Hall, Room 201 Natchitoches, LA 71497
Resident Inspector
Waterford NPS P.O. Box 822 Killona, LA 70057-0751
Regional Administrator, Region IV U.S. Nuclear Regulatory Commission 611 Ryan Plaza Drive, Suite 400 Arlington, TX 76011
REQUEST FOR ADDITIONAL INFORMATION WATERFORD STEAM ELECTRIC STATION, UNIT 3 USE OF NEXT GENERATION FUEL TAC NO. MD6299
- 1. For the proposed change to add items 15, 16, 17, 18, and 19 (five references) to core operating limit report Technical Specifications 6.9.1.11.1, please explain the connection or relationship between or among the referenced approved methodologies used. There
are, for example, three moderator temperature coefficient methods, four axial shape index methods, three linear heat rate methods, etc. The justification is needed because the application of these methodologies is planned for the coming cycle and many approved methodologies are proposed to support the same cycle-specific parameter.
- 2. Please provide the technical basis to justify that 72.8 percent is the conservative maximum allowable safety-injection tank level.