TAC:56522
From kanterella
(Redirected from TAC:56523)
Jump to navigation
Jump to search
Request for: Approved, Closed | |
Questions Answers Results Other: 05000366/LER-1985-005-01, :on 850329,determined That Battery Surveillance Procedure Contained Acceptance Criteria That Did Not Satisfy Tech Specs.Caused by Procedural Inadequacy.Procedure Being Revised, ML20062D710, ML20099E184, ML20099L199, ML20099L430, ML20202F737, ML20237K230, ML20237K247 | |
| From | |
MONTHYEARML20062D7101982-07-29029 July 1982
[table view]Proposed Temporary Changes to Tech Specs 3/4 8-1 & 3/4 8-2 to Extend 72-h Limiting Condition for Operation for One Inoperable Diesel Generator ML20062D6901982-07-29029 July 1982 Application for Amend to License NPF-5,temporarily Changing Tech Specs 3/4 8-1 & 3/4 8-2 to Extend 72-h Limiting Condition for Operation for One Inoperable Diesel Generator ML20079E2151984-01-0909 January 1984 Submits Info on Diesel Generator Quick Starts & Opinion of Effect on Reliability.Record of Diesel Cold Starts for 1983 Summarized,In Response to NRC 831216 Request ML20095D2031984-08-16016 August 1984 Requests Extension Until 841107,to Respond to Request for Info Re Reliability & Upgrading of Diesel Generators,Per Generic Ltr 84-15.Extension Due to Workload at Site for Unit 2 Recirculation Pipe Replacement Outage ML20099E1841984-11-0707 November 1984 Proposed Tech Spec Changes Re Limiting Conditions for Operation,Surveillance Requirements & Bases for Diesel Generator Operability,In Response to Generic Ltr 84-15 ML20099E1641984-11-0707 November 1984 Application to Amend Licenses DPR-57 & NPF-5,in Response to Generic Ltr 84-15, Proposed Staff Actions to Improve & Maintain Diesel Generator Reliability. Amend Revises Tech Specs Re Limiting Conditions for Operation.Fee Paid ML20099L4301984-11-20020 November 1984 Corrected Page 3/4 8-3 to Tech Specs Re Surveillance Requirements ML20099L1991984-11-20020 November 1984 Forwards Corrected Page 3/4 8-3 of Diesel Generator Tech Specs Covering Surveillance Requirements for Electrical Power Sys,In Response to Generic Ltr 84-15 05000366/LER-1985-005-01, :on 850329,determined That Battery Surveillance Procedure Contained Acceptance Criteria That Did Not Satisfy Tech Specs.Caused by Procedural Inadequacy.Procedure Being Revised1985-04-26026 April 1985
ML20129E4711985-05-30030 May 1985 Notification of 850613 Meeting W/Util in Bethesda,Md to Discuss Proposed Changes to Diesel Generator Tech Specs ML20202F7371986-03-31031 March 1986 Proposed Tech Specs Re Reduction of Number of Fast Cold Starts,Frequency of Testing Determined to Be Abusive & Elimination of Excessive Testing to Diesel Generators ML20202F7021986-03-31031 March 1986 Application for Amends to Licenses DPR-57 & NPF-5,revising Tech Specs to Reduce Number of Fast Cold Starts,Eliminate Excessive Testing & Reduce Frequency of Testing Determined to Be Abusive to Diesel Generators ML20237K2301987-08-25025 August 1987 Amends 147 & 83 to Licenses DPR-57 & NPF-5,respectively, Modifying Tech Specs Re Testing of Onsite Emergency Diesel Generators ML20237K2471987-08-25025 August 1987 Notice of Denial of Amends to Licenses DPR-57 & NPF-5 & Opportunity for Hearing on 860331 Request Re Extension from 2 to 24 H,Time Allowed to Restore Operability of 1 of 2 Inoperable Diesel Generators ML20237K2351987-08-25025 August 1987 Safety Evaluation Supporting Amends 147 & 83 to Licenses DPR-57 & NPF-5,respectively 1984-08-16 | |
Retrieved from "https://kanterella.com/w/index.php?title=TAC:56522&oldid=5487532"