Pages that link to "NRC Form 36dA"
Jump to navigation
Jump to search
The following pages link to NRC Form 36dA:
Displayed 19 items.
- 05000413/LER-1989-009-03, :on 890515,personnel Identified Potential Violation of Intent of Tech Spec 4.9,4.1 Associated W/ Incore Instrumentation Room Purge Subsys.Caused by Incomplete Tech Specs.Tech Spec Change Made (← links)
- 05000328/LER-1988-013, :on 880316 & 17,rod Group Demand Position Indication Not within +/-2 Steps of Demand Position Per Tech Tech Spec 3.1.3.3.First Event Caused by Demand Step Counter Circuitry Failure & Second by Internal Binding (← links)
- 05000285/LER-1998-009, :on 980722,WDS CIV Was Noted Outside Design Basis.Caused by Inadequate Design Interface W/Existing Sys. HCV-500A Was Repaired,Tested & Returned to Service on 980626 (← links)
- 05000366/LER-1998-002-02, :on 980318,assembly Error Led to Malfunctioning Governor Causing EDG Inoperability.Caused by Sticking Shutdown Solenoid on DG Governor.Established Periodic Replacement Schedule for Solenoid (← links)
- 05000317/LER-1998-005, :on 980312,spare Reactor Trip Breaker Did Not Meet TS Requirements.Caused by Inadequate Procedures.Revised Procedures to Include Testing Requirements for Spare Breaker (← links)
- 05000352/LER-1999-007, :on 990617,inadvertent Emergency Svc Water Start During Test Equipment Installation Occurred.Caused by Personnel Error.Procedure Revised.With (← links)
- 05000443/LER-1997-016, :on 971105,determined That AMSAC C-20 Interlock Setpoint Is non-conservative.Caused by Lack of Precise Definition of Required Power Level for C-20 Interlock.Will Revise AMSAC C-20 Interlock Setpoint (← links)
- 05000266/LER-1997-034, :on 970707,discovered Unplanned Loss of Voltage on Train B Safeguards Buses.Caused by Inadequate Design & Design Review for Installation of New Train B Edgs.Incorrect Wiring Reworked (← links)
- 05000382/LER-1997-022, :on 970614,RWSP Boron Concentration Was Lower than Rcs,In Volation of TS 3.7.6.2b.Caused by Incorrect Assumptions by Operations Dept Staff & Mgt.Waterford 3 Will Submit TS Change for TS 3.7.6.2b (← links)
- 05000219/LER-1996-011, :on 961026,discovered Primary Leak Rate Above TS Limit.Caused by Improper Valve Reassembly on V-26-5 During 16R Outage.Replaced Valve V-26-5 O Rings,Reassembled Subject Valve & Revised Procedures (← links)
- 05000321/LER-1997-002-01, :on 970207,determined TS Surveillance Requirement 3.8.1.9 Had Not Been Adequately Implemented. Caused by Less than Adequate Procedures in Logic Sys Functional Test.Operating Order Issued (← links)
- 05000285/LER-1996-011, :on 961030,containment Closure Breached While Moving Fuel.Caused by Failure to Maintain Valves & Follow & Enforce SO-G-20A Requirements.Rev of Policies & Procedures Re Control & Maint of Containment Closure (← links)
- 05000458/LER-1992-028, :on 921207,discovered That All Source Range & Intermediate Range Monitors Were Inoperable.Caused by Failure of Shift Supervisor to Recognize That SR Not Current.Procedures Modified (← links)
- 05000335/LER-1996-010, :on 960730,upper & Lower Detector Leads for Linear Range Ni Were Reversed on Channels A,C & D.Mod Package for Replacement of RPS Ni Drawers Contained Design Error.Drawers Have Been Reconnected & Retested (← links)
- 05000325/LER-1995-022, :on 951220,HPCIS Discharge Flow Element Gasket Leaked.Caused by Improperly Installed Gasket.Gasket & Hydraulic Actuator Were Replaced (← links)
- 05000498/LER-1991-021, :on 911010,power from 1J Bus Lost When Electrician Misapplied Multimeter Test Leads in Energized Circuit,Resulting in Reactor Trip.Caused by Personnel Error. Pump Reenergized & Training Session Held (← links)
- 05000333/LER-1994-009-01, :on 941129,partial Invalid Primary Containment Isolation as Result of Personnel Error During Electrical Bus Power Source Transfer.Operations Personnel Restored Sys to Normal in Accordance W/Plant Procedures (← links)
- 05000250/LER-1990-003, :on 900220,determined That Spent Fuel Pool 3B Shaft Failure Resulted in Damage to Pump Mechanical Seal & Release of Borated Contaminated Water.Procedure O-PMM-061.1 Revised (← links)
- 05000266/LER-2004-003, Re Reactor Shutdown Required by Containment Penetration Tsac 3.6.3.C (← links)