- ML18277A074 (← links)
- ML20105A122 (← links)
- 05000317/LER-1989-011, :on 890630,missing Fire Damper Discovered in Spent Fuel Pool Ventilation Sys.Caused by Error in Facilities Change Request That Installed Fire Dampers.Action Statement Entered & 1 H Rept Made (← links)
- 05000318/LER-1989-009-01, :on 890522,fire Damper Found in Closed Position by Fire Protection Design Engineer.Caused by Failure of Damper Fusible Link.Link Replaced,Damper Opened & Damper Insp Procedure Improved & Clarified (← links)
- 05000318/LER-1989-010-01, :on 890623,determined That Tech Spec Surveillance 4.7.12a Not Performed within Required Time Interval.Caused by Procedural Problem.Overdue Surveillance Performed.Surveillance Procedure Revised (← links)
- 05000317/LER-1989-013, :on 890731,missing Steps in Surveillance Test Procedure Discovered Resulting in Failure to Comply W/Tech Spec Surveillance.Caused by Personnel Error.Review of Test Procedures Performed to Satisfy Requirements (← links)
- 05000317/LER-1989-007-01, :on 890317,identified Bent Vertical Support for Piping Restraint on Shutdown Cooling Portion of LPSI Suction Piping.Caused by Slamming Shut of LPSI Pump 12 Discharge Check Valve.Restraint Replaced (← links)
- 05000317/LER-1988-009, :on 880824,Unit 1 Tripped on Loss of Load When Main Turbine Tripped on High Steam Generator Level.Caused by Vibration & Stress.Walkdown Performed on Selected Components & Pressure Switch Relocated (← links)
- 05000318/LER-1992-007, :on 920929,Calvert Cliffs Unit 2 Manually Tripped Due to High Temps on Main Turbine Rear Thrust Bearing Faces.Caused by 23 Moisture Separator/Reheater Relief Valves Stuck Open.Valves Repaired (← links)
- 05000318/LER-1992-004-01, :on 920718,both Independent Saltwater Loops Declared Inoperable.Caused by Blown Fuse in Control Circuit. Blown Fuse Replaced,Temporary Guidance Issued & TS Equipment Maint Policy Will Be Developed (← links)
- 05000317/LER-1995-006, :on 951116,manual Reactor Trip Occurred Due to Loss of 12 SG Feed Pump.Caused Oil Losses Allowing Pressure to Drop Before Standby Pump Could Restore Pressure.Trip Mechanism & Thrust Cleaned & Adjusted (← links)
- 05000317/LER-1995-003-01, :on 950730 & 31,entered TS 3.0.3 Due to High Bay Water Temps.Administration Limit for Bay Water Temp Raised & Current Unit 1 & Unit 2 SW Tube Type HXs Will Be Replaced (← links)
- 05000318/LER-1994-005-01, :on 940924,reactor Trip Experienced Due to Main Turbine Governor Valve Opening.Wire on 21 Governor Valve LVDT Tightened & Wiring on All Other Unit 2 Main Turbine Throttle & Governor Valves Checked (← links)
- 05000318/LER-1991-002, :on 910327,ESF Actuation Occurred While Operator Was Restoring ESF Actuation Sys AL Actuation Logic Cabinet.Caused by Personnel Error.Operators Counseled & Other Personnel Informed of Event (← links)
- 05000318/LER-1994-004-01, :on 940810,experienced Reactor Trip Due to Main Generator Trip.Caused by Loss of Field Relay.Replacement of Failed Components Completed & Refresher Training Provided for Operators (← links)
- 05000317/LER-1994-004, :on 940221,discovered Excessive Corrosion of Incore Instrumentation Flange Components Due to Presence of Wet Boric Acid.Boric Acid Corrosion Insp Program Will Be Revised (← links)
- 05000317/LER-1994-003, :on 940321,noticed Leakage from Rcs.Caused by Pwscc.Corrective Action:Sleeve Location B-3 & FF-1 Have Been Plugged W/Alloy 690 Plug Welded to Outer Diameter of Pzr Lower Head (← links)
- 05000317/LER-1993-008, :on 931203,determined Removal of EDG Room Shield Door Could Render Other EDGs Inoperable.Caused by Lack of Procedural Controls.Maint Procedure Will Be Generated W/Appropriate Precautions (← links)
- 05000317/LER-1990-014, :on 900414,Delta T Power Channels Declared Inoperable.Caused by Inadequate Written Procedure & Personnel Error.Changes to Operating Procedures to Provide Addl Guidance to Operators Approved (← links)
- 05000317/LER-1990-013, :on 900413,determined That Axial Shape Index Channels Out of Spec & Inoperable.Caused by Inadequate Understanding of Design Basis for Excore/Incore Comparison. Design Basis for Excore/Incore Improved (← links)
- 05000317/LER-1990-009, :on 900224,failure to Meet Action Requirement Re Tech Spec 3.7.12.Caused by Personnel Error.Cables Removed from Doorway in Charging Pump Room & Not Allowed to Be Placed in Doorway (← links)
- 05000317/LER-1989-017, :on 890907,determined That Discrepancy in Acceptance Criteria of Surveillance Test Procedure M-452-0 Resulted in Failure to Fully Comply W/Requirements of Tech Spec 3.9.12.Main Cause Undetermined (← links)