Pages that link to "Control rod 10-23"
Jump to navigation
Jump to search
The following pages link to Control rod 10-23:
Displayed 50 items.
- IR 05000373/2012005 (← links)
- ML14350A161 (← links)
- ML14350A134 (← links)
- ML110200547 (← links)
- ML101590173 (← links)
- ML101590080 (← links)
- ML18039A240 (← links)
- ML18024A518 (← links)
- BVY 06-013, Summary Reports for In-Service Inspection and Repairs or Replacements (← links)
- ML19207B105 (← links)
- ML19323E419 (← links)
- ML18239A448 (← links)
- ML18239A446 (← links)
- ML19323G651 (← links)
- ML20008E187 (← links)
- ML20050E236 (← links)
- ML040710416 (← links)
- ML033220588 (← links)
- ML20065E166 (← links)
- ML030130011 (← links)
- ML20083K314 (← links)
- ML20133J496 (← links)
- IR 05000278/1986009 (← links)
- ML20205T196 (← links)
- IR 05000271/1986010 (← links)
- ML20203G649 (← links)
- ML20202J023 (← links)
- ML20214J794 (← links)
- ML20214G314 (← links)
- ML20212C660 (← links)
- ML20212A241 (← links)
- ML20245E631 (← links)
- ML20215C874 (← links)
- ML20244E313 (← links)
- ML20236K594 (← links)
- ML20236H670 (← links)
- ML20237G332 (← links)
- 05000325/LER-1987-016-01, :on 870522,determined That Functional Testing of Control Rod Block Function of Reactor Power Intermediate Range Monitors Not Performed from 870510-17.Caused by Personnel Error.Procedures Revised (← links)
- 05000278/LER-1986-009-02, :on 860318,manual Scram Occurred.Caused by Series of Personnel Errors Involving Failure to Withdraw Correct Control Rod & Verify Proper Position of Control Rod. Personnel Counseled & Procedures Revised (← links)
- 05000278/LER-1976-045-03, /03L:on 760508,reactor Manually Scrammed at 30% Power & Rod 10-23 Failed to Fully Insert on Auto Scram Signal.Cause Not Identified.Rod Successfully Friction Tested & Considered Operable (← links)
- 05000321/LER-1982-049-01, /01T-0:on 820517,fuel Loading Performed W/O All Control Rods Fully Inserted.Caused by Second Shift Resuming Operations W/O Knowing First Shift Suspended Operations Due to Inability to Insert Rods.Procedure to Be Revised (← links)
- IR 05000333/1981001 (← links)
- ML20034E729 (← links)
- IR 05000219/1980019 (← links)
- ML20008E193 (← links)
- IR 05000219/1980034 (← links)
- 05000219/LER-1980-017-01, /01T-0:on 800516,while Performing Control Rod Interference checks,green-green Rod Position Indication Remained Illuminated While Withdrawing Rod 10-23.Caused by Operator & Procedure in Bypass & Component Failure (← links)
- IR 05000277/1979029 (← links)
- ML19249A282 (← links)
- 05000325/LER-1979-047-03, /03L-0 on 790719:during Normal Reactor Startup, full-in Indication Remained on After Rod 10-23 Was Pulled. No Indication of full-in on Rod 42-11 Given & full-in Signal Not Sent to Control Circuitry by Rod 22-11.Repaired (← links)