SVP-08-033, 90-Day Post Outage ISI Letter
| ML081570340 | |
| Person / Time | |
|---|---|
| Site: | Quad Cities |
| Issue date: | 05/29/2008 |
| From: | Tulon T Exelon Generation Co, Exelon Nuclear |
| To: | Document Control Desk, Office of Nuclear Reactor Regulation |
| References | |
| FOIA/PA-2010-0209, SVP-08-033 | |
| Download: ML081570340 (68) | |
Text
Exeln Exelon Generation Company, LLC www.exeloncorp.com Nuclear Ouad Cities Nuclear Power Station 22710 206th Avenue North Cordova, IL 61242-9740 1 0CFR50.55a SVP-08-033 May 29, 2008 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Quad Cities Nuclear Power Station Unit 2 Renewed Facility Operating License No. DPR-30 NRC Docket No. 50-265
Subject:
90-Day Post Outage ISI Letter Enclosed is the Quad Cities Nuclear Power Station Unit 2 Post-Outage (90 day) Summary Report for Inservice Inspection examinations and Repair/Replacement activities conducted from the end of the April 2006 refueling outage through the March 2008 refueling outage.
This report is due within 90 days after the end of the Unit 2 March 2008 refueling outage, which is June 28, 2008. This report documents examinations performed during the second period of the fourth inspection interval.
This report is submitted in accordance with the requirements of ASME Section XI, Article IWA-6200, "Requirements."
If there are any questions or comments concerning this letter, please refer them to Mr. Wally Beck, Regulatory Assurance Manager, at (309) 227-2800.
Sincerel),,
Timothy J. Tulon Site Vice President Quad Cities Nuclear Power Station
Attachment:
Quad Cities Nuclear Power Station - Unit 2 Post Outage (90 day) Summary Report cc:
Regional Administrator - NRC Region III NRC Senior Resident Inspector - Quad Cities Nuclear Power Station Aco,-
ATTACHMENT Quad Cities Nuclear Power Station-Unit 2 Post Outage (90 day) Summary Report
Quad Cities Nuclear PowerStation - Unit 2 Post-Outage (90 Day) Su'mmary Report Due June 28, 2008 Refueling Outage:Q2R19 Outage Start Date: March 3, 2008 Outage End Date: March 30,'2008 Comercial Service Date: March'10, 1973
.. :22710 2 0 6 h Avenue North, Cordova, IL 614242-.
.Exelon Generation Company, L.L.C.
300 Exelon Wy, Kennett Square, PA 1.9348 Prepared'by:
-*,7-Mathew Rice.
Reviewed by:
Andrew Mitchell.
Reviewed by:
,,/..-
- "David Peters eer)
Reviewed by:
2 Gary KnappS*-nubber "Engineer)
Approved by:LtA4j&iI
'Exelon Generation Company, L.L.C.
Quad Cities Nuclear Power Station 300 Exelon Way Unit 2 Kennett Square, PA 19348 22710 2 0 6th Avenue North, Commercial Service Date March 10, 1973 Cordova, IL 61242 Table of Contents 1.0 IN TR O D U C T IO N..............................................................................................................................................
3 1.1.
OUTAGE, PERIOD AND INTERVAL START AND END DATES.................................................................... 3 1.2.
EXAM INATION PROGRAM R EQUIREM ENTS............................................................................................... 3 2.0 N IS-1 F O R M.......................................................................................................................................................
4 3.0 ABSTRACT OF EXAMINATIONS, CONDITIONS NOTED AND CORRECTIVE MEASURES.......... 6 3.1.
SECTION XI EXAMINATIONS
SUMMARY
............................................................................................... 6 3.2.
BW RV IP-75/G ENERIc LETTER 88-01....................................................
1..............................................
7 3.3.
IN V ESSEL IN SPECT IO N S (IV I)....................................................................................................................
7 Table 3.1-1 Quad Cities Unit 2 ASME Section XI Outage Summary...............................................
9 Table 3.1-1A Quad Cities Unit 2 ASME Section XI Limited Coverage Scope.................................
12 Table 3.1-2 Quad Cities Unit 2 Pressure Testing Summary..........................................................
13 Table 3.1-3 Quad Cities Unit 2 Snubber Functional Tests............................................................
14 Table 3.1-4 Quad Cities Unit 2 Conditions Noted on ASME Code Components and Corrective A ctions...................................................................................
16 Table 3.2-1 Quad Cities Unit 2 BWRVIP-75-A/GL 88-01 Outage Scope......................................
18 Table 3.3 Number and Percentage of Examinations Completed...................
..................... 19 4.0 REPAIR / REPLACEMENT
SUMMARY
20 4.1.
N IS -2 IN D EX..........................................................................................................................................
2 0 T ab le 4.1-1............................................................................................................................................
2 0 4.2.
N IS -2 F O R M S.........................................................................................................................................
2 2 2 of 22
Exelon Generation Company, L.L.C.
Quad Cities Nuclear Power Station 300 Exelon Way Unit 2 Kennett Square, PA 19348 22710 2 0 6 th Avenue North, Commercial Service Date March 10, 1973 Cordova, IL 61242 1.0 Introduction 1.1.
Outage, Period and Interval Start and End Dates This Inservice Inspection Summary Report addresses examinations performed between the end of the previous refueling outage April 17, 2006 through the end of the most recent refueling outage. This most recent refueling outage was the 19th refueling outage for Quad Cities Nuclear Power Station Unit Two. The outage started March 3, 2008 and was completed March 30, 2008 when the unit returned to service.
This refueling outage was the only scheduled outage during the second inspection period of the fourth inspection interval, which began on March 10, 2003. The first inspection period of the fourth inspection interval ended on April 17, 2006. The second inspection period is scheduled to end March 9, 2010. This report covers examinations performed to the second period, fourth interval requirements.
Tests, examinations, repairs and/or replacements associated with American Society of Mechanical Engineers (ASME) Code,Section XI were witnessed or otherwise verified by the Authorized Nuclear Inservice Inspectors. Non-ASME Section XI or augmented examinations were not witnessed or otherwise verified by the Authorized Nuclear Inservice Inspectors and are marked "Not Required" or "N/A" on the applicable examination reports.
The Authorized Nuclear Inservice Inspectors are inspectors of the Hartford Steam Boiler Inspection & Insurance Company of Connecticut (HSB-CT). The HSB-CT Regional Office is located at 2443 Warrenville Road Suite 500, Lisle, Illinois, 60532-9871.
1.2.
Examination Program Requirements The examination requirements of ASME Boiler and Pressure Vessel Code,Section XI, Division 1, "Rules for Inservice Inspection of Nuclear Power Plant Components", 1995 Edition through 1996 Addenda were implemented for Class 1, 2 and 3 components except where written relief has been granted by the NRC. Written relief, in the form of Relief Request 14R-02 approving Risk Informed Inservice Inspection (RI-ISI) as an inspection program alternative for Code Categories B-F, B-J, C-F-1 and C-F-2, was utilized during Q2R19. The ultrasonic examination volumes for RI-ISI components were increased from the Section XI requirements to meet the RI-ISI Program.
The ultrasonic examination requirements of ASME Boiler and Pressure Vessel Code,Section XI, Appendix VIII, 1995 Edition with Addenda through 1996, as required by 10 CFR 50.55a, "Codes and Standards", and amended by the Federal Register Notice 64 FR 51370 dated September 22, 1999 is executed through the Performance Demonstration Initiative (PDI) Program according to the schedule defined in 10 CFR 50.55a(g)(6)(ii)(C),
for wrought austenitic piping welds, ferritic piping welds, bolts/studs, reactor vessel welds, nozzle to vessel welds, nozzle inside radius sections and full structural overlaid wrought austenitic piping welds.
3 of 22
'Exelon Generation Company, L.L.C.
300 Exelon Way Kennett Square, PA 19348 Commercial Service Date March 10, 1973 Quad Cities Nuclear Power Station Unit 2 22710 206th Avenue North, Cordova, IL 61242 2.0 NIS-1 Form FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules
- 1. Owner Exelon Generation Company, L.L.C., 300 Exelon Way, Kennett Square, PA 19348 (Name and Address of Owner)
- 2. Plant Quad Cities Nuclear Power Station, 22710 2 0 6 1h Avenue North, Cordova, IL 61242 (Name and Address of Owner)
- 3. Plant Unit Two
- 4. Owner Certificate of Authorization (if required)
N/A N/A
- 5. Commercial Service Date 3/10/73
- 6. National Board Number for Unit
- 7. Components Inspected Component or Manufacturer Manufacturer State or National Appurtenance Or Installer or Installer Province No.
Board No.
Serial No.
Reactor Pressure Chicago Bridge & Iron T-22 B0075000 N/A Vessel Reactor Recirculation Dravo Corp.
N/A - See Table 3.1-1 N/A N/A Core Spray Grinnell N/A - See Table 3.1-1 N/A N/A Feedwater Grinnell N/A - See Table 3.1-1 N/A N/A Main Steam Grinnell N/A - See Table 3.1-1 N/A N/A Residual Heat Grinnell N/A - See Table 3.1-1 N/A N/A Removal Control Rod Drive Grinnell N/A - See Table 3. 1-1 N/A N/A High Pressure Coolant Grinnell N/A - See Table 3.1-1 N/A N/A Injection Note: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8V2 in. x 111/2 V2 in.,
(2) information in items 1 through 6 on this report is included on each sheet unless they are coded N/A, and (3) each sheet is numbered and the number of sheets is recorded at the bottom of this form.
4 of 22
Exelon Generation Company, L.L.C.
300 Exel!n way Kennett Square, PA 19348 Commercial Service Date March 10, 1973 Quad Cities Nuclear Power Station Unit 2 22710 206t" Avenue North, Cordova, IL 61242 FORM NIS-1 (Back)
- 8. Examination Dates:
- 9. Inspection Period Identification:
4/18/06 to 3/30/08:
2 n Period, From 4/18/06 to 3/9/10 for the 4th, Intefval"
- 10. Inspection Interval Identification:
- 4th Interval - From 3/10/03 to
- 319/13-1 i. Applicable Edition of Section XI 1995 Addenda 1996 12.2 Date/Revision of Inspection Plan:
.9/21/07 Revision 4 (4th Interval)..
- 13. Abstract of Examination and Tests. incluide a list of examinations and tests and a statement concerniig status: of work required for the Inspection Plan. See Section.3.0 and Tables 3.1-1. 3.1-!A. 3.1-2, 3.1-3, 3.1-4, 3.2:land 3.3.:-ý-.
- 14. Abstract of Results of Examinations and Tests. See Section 3.0 and Tables-3.1-1 3.1 -1 A, 3.1-2, 3.1-31 3.1-4. 3.2-1 and 3.3
- 15. Abstract of Corrective Measures. See Section, 3.0 and Table 3.1-4.
We certify that a) the statement made in this report are correct, b) the examinations and tests meet:
ihe Inspection Plan as required by the ASME CodejSection XI, and c) correctivemeasures taken conform to the ASME Code, Section-XI.
Certificate of 'Authorization No. (if applicable)
N/A Expiration-Date N/A Date 27 20 Oe' Signed.
Exelon Corporation By Owner CERTIFICATE OF INSERVICE INSPECTION I, the under signed, holding a valid commission issued by the National Board of Boiler and Pressure Vessel:i 4/i,.:.
Inspectors and the State of
- Illinois, and employed by Hartford"Steami Boiler of Connecticut of.
o C0oiecticut have inspected the components described in the Owner's Report during the period 4/18/06:...
To 3/30/08 and state that to the best of my knidowledge and belief, the Owner has'perf6rmed examinations and tests §and'taken corrective measUr~es described in this Owner's iReport in accordance with the Inspection Plan and as required by the ASME Code,Section XI.
By signing this certificate neither the Insector nor his employer makes a:y warranty, expressed or implied, concerning tiheexaminations. tests, and corrective measures described in thisOwner's Report. Furthermore;,neither the Inspector nor his employer shall be liable in any manner for any personal~injury or property damageor a loss of any kindarising from or connected with this inspection.
In.sOctor's Signature Commissions q
National Board, State, Province, and Endorsements.
Date Date 0(
1" 20 5 of 22
Exelon Generation Company, L.L.C.
Quad Cities Nuclear Power Station 300 Exelon Way Unit 2 Kennett Square, PA 19348 22710 206 Avenue North, Commercial Service Date March 10, 1973 Cordova, IL 61242 3.0 Abstract of Examinations, Conditions Noted and Corrective Measures 3.1.
Section XI Examinations Summary A combination of ultrasonic (UT), liquid penetrant (PT), magnetic particle (MT) and visual (VT) testing were performed prior to and during the 1 9th refueling outage on ISI Program components. Examinations were performed by General Electric (GE) and Exelon Nuclear personnel. Volumetric and surface examinations were compared with the recorded results of previous examinations for applicable Class 1, 2 and RI-ISI components. ISI inspections comprised of 59 volumetric (35 were RI-ISI, Category R-A welds), eight (8) surface examinations and 48 VT-1 and VT-3 examinations, and 12 component examinations by VT-2 were performed on Class 1, 2 and RI-ISI. components. Six (6) of the visual exams were scope expansion exams as a result of indications found on two hangers that required repair or adjustment on two hangers. The two hangers were returned to their design condition and received an acceptable VT-3 exam following adjustment. Two (2) visual examinations were follow-ups examinations in accordance with IWF-2220 (b). The subsequent examinations found no additional relevant conditions. Code cases used for ISI or Repair/Replacement activities are listed in the ISI Program Plan.
Table 3.1-1 A, "Quad Cities Unit 2 ASME Section XI Limited Coverage Summary" contains the volumetric examinations that did not meet coverage requirements of ASME Section XI Code (i.e. greater than 90 percent of the specified examination volume). These exams were limited by design specific geometry. Accessibility could not be improved.
Eight (8) of the nine (9) examinations were on nozzle welds that have received relief for limitations in the past. The 8 nozzle welds coverage increased over the previous interval examinations. The ninth limited examination was the volumetric exam of the reactor vessel top head to flange weld (RPV-THHF). Relief requests as required by 10 CFR 50.55a(g)5(iii) and 50.55a(g)5(iv) will be generated and submitted within twelve (12) months following the end of the inspection interval.
Pressure testing VT-2 examinations not related to repair/replacement activities are documented in Table 3.1-2, "Quad Cities Unit 2 Pressure Testing Summary". The Class 1 and 2 Vessel Leakage Test and the Reactor Vessel Head Flange Seal Leak Detection System Test were performed in accordance with the 1995 Edition 1996 Addenda of the ASME Code for the second period of the fourth Interval.
Containment inspections were completed for Unit 2 for the end of the 10-year interval in accordance with 1992 Edition through the 1992 Addenda of ASME Section XI Subsection IWE. All accessible surfaces were examined. No corrective actions were required. This constitutes the end of the 10-year interval for Subsection IWE only.
Exelon personnel performed functional tests on a total of fourteen (14) snubbers for operability per the Service Life Monitoring/Failure Trending Sample and ASME OM Code Subsection ISTD. Eight (8) of the fourteen (14) snubbers were ASME Section XI Code designated. Of the fourteen (14) snubbers tested, Three (3) were found unacceptable for continued operation. An additional thirty (30) snubbers were tested for expanded sampling 6 of 22
Exelon Generation Company, L.L.C.
Quad Cities Nuclear Power Station 300 Exelon Way' Unit 2 Kennett Square, PA 19348 22710 2 0 6th Avenue North, Commercial Service Date March 10, 1973 Cordova, IL 61242 due to snubber functional testing failures. Twenty-one (21) of the thirty (30) expanded sample snubbers were ASME Section XI Code designated. Of the additional thirty (30) snubbers tested, five (5) snubbers were found unacceptable for continued operation. Five (5) unacceptable snubbers were replaced with Lisega hydraulic snubbers. The remaining three (3) unacceptable snubbers were replaced with like-for-like units. In addition, a planned replacement of five (5) snubbers with Lisega snubbers was performed as part of Service Life Monitoring. Three (3) of the snubbers removed for service life replacements were taken credit for as part of the snubber sample expansion since they met the sample expansion criteria specified by OM code ISTD 7.9.3. Snubber testing activities are summarized in Table 3.1-3, "Quad Cities Unit 2 Snubber Functional Tests". Seven of the eight snubbers that failed were ASME Section XI components (Table 3.1-3 lists Code and non-Code to encompass scope expansion).
Table 3.1-4 "Quad Cities Unit 2 Conditions Noted on ASME Code Components and Corrective Actions" summarizes the conditions noted during the examinations and corrective measures taken prior to returning the unit to service.
Table 3.3 identifies number and percentage of examinations completed in the fourth interval.
3.2. BWRVIP-75-A/Generic Letter 88-01 Augmented examinations required by BWRVIP-75-A, "BWR Vessel and Internals Project Technical Bases for Revisions to Generic Letter 88-01 Inspection Schedules", were implemented in this outage (see Table 3.2-1). Four Category C IGSCC Susceptible welds were examined including one dissimilar metal weld utilizing PDI qualified examination techniques. No relevant indications were found and examination coverage was greater than 90%. This is consistent;.with previous examination results.
3.3. Invessel Inspections (IVI)
The only ASME Section XI inspection credited during Q2R19 IVVI activities is the once-per-period B-N-I VT-3 inspection of the vessel interior. Credit is being taken for this examination due to nature and number of other IVVI examinations in the vessel annulus region per Relief Request 14R-15, "Alternative Requirements to ASME Section XI, B-N-I and B-N-2 using BWRVIP Guidelines, Fleet Relief," submitted April 19, 2007.
To implement the requirements of the Boiling Water Reactor Vessel Internals Program, (BWRVIP), GE was contracted to perform the In-Vessel Visual Inspections (IVVI). The following components and assemblies were examined:
a 158 welds and components on jet pump assemblies in accordance with the BWR Jet Pump Assembly Inspection and Flaw Evaluations Guidelines (BWRVIP-41 -R1),
a 12 core spray piping welds in accordance with the BWR Core Spray Internals Inspection and Flaw Evaluation Guidelines (BWRVIP-18-A),
- Six core shroud vertical welds outside the beltline in accordance with the BWR Core Shroud Inspection and Flaw Inspection Guideline (BWRVIP-76),
7 of 22
Exelon Generation Company, L.L.C.
Quad Cities Nuclear Power Station 300 Exelon Way Unit 2 Kennett Square, PA 19348 22710 2061h Avenue North, Commercial Service Date March 10, 1973 Cordova, IL 61242 0
The four top guide aligner pins and accessible areas of the top guide rim weld in accordance with BWR Vessel and Internals Project Top Guide Inspection and Flaw Evaluation Guidelines (BWRVIP-26-A),
0 Five Control Rod Guide Tubes in accordance with BWR Vessel and Internals Project Boiling Water Reactor Lower Plenum Inspection and Flaw Evaluation Guidelines (BWRVIP-47-A),
292 steam dryer welds and components per GE recommendations and consistent with the re-inspection criteria in pending Revision 1 to BWR Vessel and Internals Project Steam Dryer Inspection and Flaw Evaluation Guidelines (BWRVIP-139).
No new indications and no change in previous indications that were left as-is were identified on the Unit 2 steam dryer, which required repair during Q2RI18.
The following augmented examinations were performed as part of the Q2R 19 IVVI activities:
All 20 jet pump main wedges were inspected for evidence of main wedge (WD-1) movement. Two jet pumps (#5 and #8) have main wedge conditions that Quad Cities is monitoring in particular. The condition of none of the jet pumps has changed since Q2R1 8 (and Q2R1 7). Quad Cities shall continue to monitor the condition of jet pump wedges during future IVVI visual inspections.
Inspected the eight Feedwater Sparger End Bracket surfaces for evidence of wear.
These inspections were a follow-up to evidence of wear from the pins observed during Q2R 18. Seven of the eight brackets showed evidence of wear similar to that observed during Q2R18. This is not a concern for the immediate future. The worst worn bracket still has greater than 90% of its original thickness remaining. Quad Cities will continue to monitor this condition while long-term repair options are being evaluated.
Follow-up inspections of previous indications to determine extent of condition were performed on the steam dryer wall support lugs. No additional damage was observed except for normal wear.
Follow-up inspections of previous indications on two steam separator gussets. No change in conditions was observed.
8 of 22
Exelon Generation Company, L.L.C.
300 Exelon Way Kennett Square, PA 19348 Commercial Service Date March 10, 1973 Quad Cities Nuclear Power Station Unit 2 22710 2 0 6th Avenue North, Cordova, IL 61242 Table 3.1-1 Quad Cities Unit 2 ASME Section XI Outage Scope (4 th Interval)
Report Number Component Class Category Item Inspection Results 2QR19-092 RPV-THHF I
B-A B1.40 UT, SURF NRI 2QR19-127 N1ONOZ I
B-D B3.90 UT NRI 2QR19-051 N8A IRS I
B-D B3.100 UT NRI 2QR19-115 N8A NOZ I
B-D B3.90 UT NRI 2QR19-119 N5A IRS I
B-D B3.100 UT NRI 2QR19-093 N5A NOZ I
B-D B3.90 UT NRI 2QR19-123 N5B IRS 1
B-D B3.100 UT NRI 2QR19-122 N5B NOZ 1
B-D B3.90 UT NRI 2QR19-121 N9 IRS 1
B-D B3.100 UT NRI 2QR19-120 N9 NOZ 1
B-D B3.90 UT NRI 2QR19-077 N31B IRS I
B-D B3.100 UT NRI 2QR19-067 N3B NOZ I
B-D B3.90 UT NRI 2QR19-075 N31D IRS I
B-D B3.100 UT NRI 2QR19-083 N3D NOZ I
B-D B3190 UT NRI 2QR19-096 N6A IRS I
B-D B3.100 UT NRI 2QRI9-095 N6A NOZ I
B-D B3190 UT NRI 2QR19-097 N6B IRS I
B-D B3.100 UT NRI 2QR19-098 N6B NOZ I
B-D B3.90 UT NRI 2QR19-094 N7 IRS I
B-D B3.100 UT NRI 2QR19-084 N7 NOZ I
B-D B3.90 UT NRI 2QR19-071 CLOSURE BUSHING I
B-G-I B6.50 VT-I NRI 2QR19-070 CLOSURE NUTS I
B-G-I B6.10 VT-I NRI 2QR19-069 CLOSURE STUDS I
B-G-I B6.20 UT NRI 2QR19-091 CLOSURE WASHERS 1
B-G-1 B6.50 VT-I NRI 2QR19-074 LIGAMENTS I
B-G-I B6.40 UT NRI 2QR19-129 2-203-3A I
B-G-2 B7.70 VT-I NRI 2QR19-117 2-203-3C 1
B-G-2 B7.70 VT-I NRI 2QR19-107 2-203-31D 1
B-G-2 B7.70 VT-I NRI 2QR19-128 2-203-4A 1
B-G-2 B7.70 VT-I NRI 2QR19-106 2-203-4C I
B-G-2 B7.70 VT-I NRI 2QR19-105 2-203-4D I
B-G-2 B7.70 VT-I NRI 2QR19-104 2-203-4G I
B-G-2 B7.70 VT-I NRI 2QR19-103 2-203-4H I
B-G-2 B7.70 VT-I NRI 2QR19-125 2-203-ASB-3C I
B-G-2 B7.50 VT-I NRI 2QR19-108 2-203-ASB-3D I
B-G-2 B7.50 VT-I NRI 2QRI9-118 2-203-ASB-4A I
B-G-2 B7.50 VT-I NRI 2QRI 9-110 2-203-ASB-4C 1
B-G-2 B7.50 VT-I NRI 2QR19-133 2-203-ASB-4D I
B-G-2 B7.50 VT-1 NRI 2QR19-132 2-203-ASB-4G 1
B-G-2 B7.50 VT-1 NRI 2QR19-131 2-203-ASB-4H 1
B-G-2 B7.50 VT-I NRI 2QR19-029 1012A-W-104A I
B-K B 10.20 SURF NRI 9 of 22
'Exelon Generation Company, L.L.C.
300 Exelon Way Kennett Square, PA 19348 Commercial Service Date March 10, 1973 Quad Cities Nuclear Power Station Unit 2 22710 206th Avenue North, Cordova, IL 61242 Table 3.1-1 (continued)
Quad Cities Unit 2 ASME Section XI Outage Scooe (4 th Interva1b Report Number Component Class Category Item Inspection Results 2QR19-027 1012B-W-101A I
B-K.
B10.20 SURF NRI 2QR19-064 2A-1003A-1 2
C-A C1.10 UT NRI 2QR19-063 2A-1003A-2 2
C-A CI10 UT NRI 2QRI9-116 1025-49 2
C-B C2.31 SURF NRI 2QR19-087 1025-53 2
C-B C2.31 SURF NRI 2QRI9-045 1402-W-204A 2
C-C C3.30 SURF NRI 2QR19-048 2306-W-206A 2
C-C C3.20 SURF NRI 2QR19-038 1010-W-201A 2
C-C C3.20 SURF NRI 2QR19-007 1401-G-203 2
F-A F1.20 VT-3 NRI 2QR19-046 1402-M-202 2
F-A F1.20 VT-3 NRI 2QR19-135 1402-W-204 2
F-A FI.40 VT-3 NRI 2QR19-047 1404-M-202.1 A&B 2
F-A FI.20 VT-3 NRI 2QR19-044 2305-W-214 2
F-A F1.20 VT-3 NRI 2QR19-039 1010-W-201 2
F-A F1.20 VT-3 NRI 2QR19-016 1010-M-203 2
F-A F1.20 VT-3 Acceptable 2QR19-004 1086-M-202 2
F-A F1.20 VT-3 Acceptable 2QR19-013 1404-M-206.2 2
F-A F1.20 VT-3 NRI 2QR19-014 1404-W-211 2
F-A F1.20 VT-3 NRI 2QR19-008, 2305-M-205 2
F-A F1.20 VT-3 Acceptable 2QR19-030 1012A-W-104 I
F-A FI.b10 VT-3 Acceptable 2QR19-028 1012B-W-101 I
F-A FI.b10 VT-3 Acceptable 2QR19-023 1025-M-102.1 A&B I
F-A FI.10 VT-3 NRI 2QR19-021 3001A-W-103 A&B I
F-A F1.10 VT-3 NRI 2QR19-019 3001B-M-103.1 I
F-A F1,10 VT-3 NRI 2QR19-020 30011B-M-105.1 I
F-A FI.10 VT-3 NRI 2QR19-022 3001D-W-104 I
F-A FI.10 VT-3 NRI 2QR19-130 30011B-M-101.1 I
F-A FI.10 VT-3 Acceptable 2QR19-109 3001C-W-103 I
F-A F1.10 VT-3 NRI 2QR19-072 1025-M-103.1 I
F-A FI.10 VT-3 NRI 2QR19-073 3204B-M-201 2
F-A Fl.20 VT-3 NRI 2QR19-037 1009A-4 2
R-A R.I I UT-E NRI 2QR19-036 1009A-6 2
R-A R1.1 I UT-E NRI 2QR19-041 1009A-9 2
R-A RI. 11 UT-E NRI 2QR19-065 1010-2 2
R-A R1.11 UT-E NRI 2QR19-060 1016A-2 2
R-A R1.20 UT-E NRI 2QR19-042 1016B-4 2
R-A R1.20 UT-E NRI 10 of 22
'Exelon Generation Company, L.L.C.
300 Exelon Way Kennett Square, PA 19348 Commercial Service Date March 10, 1973 Quad Cities Nuclear Power Station Unit 2 22710 2 0 6th Avenue North, Cordova, IL 61242 Table 3.1-1 (continued)
Quad Cities Unit 2 ASME Section XI Outage Scope (4th Interval)
Report Number Component Class Category Item Inspection Results 2QR19-034 1024A-2 2
R-A RIl. I UT-E NRI 2QR19-050 1006C-2 2
R-A Rl.II UT-E NRI 2QR19-058 1006D-2 2
R-A RI.11 UT-E NRI 2QR19-066 1006D-3 2
R-A RI.1 I UT-E NRI 2QR19-056 1006D-4 2
R-A R1.1I UT-E NRI 2QR19-053 1008B-8 2
R-A RI I UT-E NRI 2QR19-052 1009B-8 2
R-A RI. I1 UT-E NRI 2QR19-012 1012B-1 2
R-A Rl.1I UT-E NRI 2QR19-011 1012B-2 2
R-A RI.1 UT-E NRI 2QR19-006 1015B-10 2
R-A R1.20 UT-E NRI 2QR19-005 1015B-9 2
R-A R1.20 UT-E NRI 2QR19-024 1318-3 2
R-A R1.20 UT-E NRI 2QR19-003 1401-4 2
R-A R1.20 UT-E NRI 2QR19-017 10BD-S2 I..
R-A RI.11/RI.16 UT-E NRI 2QR19-025 10BD-S3 I
R-A R1.11/RI.16 UT-E NRI 2QR19-033 10BD-S4 I
R-A RI.1I/R1.16 UT-E NRI 2QR19-026 12S-S4R I
R-A R1.20 UT-E NRI 2QR19-009 12S-F5AR I
R-A R1.20 UT-E NRI 2QR19-031 12S-S4AR I
R-A R1.20 UT-E NRI 2QR19-113 02H-S1 I
R-A R1.20 UT-E NRI 2QR19-112 02J-SI I
R-A RI.20 UT-E NRI 2QR19-111 02L-S I 1
R-A R1.20 UT-E NRI 2QR19-101 02M-FIA I
R-A R1.20 UT-E NRI 2QR19-124 30A-S33 I
R-A R1.20 UT-E NRI 2QR19-126 30D-S35 I
R-A R1.20 UT-E NRI 2QR19-134 30D-S37
. I R-A RI.20
. UT-E NRI 2QR19-114 N10-F1 I
R-A R1.20 UT-E NRI 2QR19-079 14A-SI I
R-A RI. 1II/RI. 16 UT-E NRI 2QR19-078 32D-FI I
R-A R1.11/RI.18 UT-E NRI 11 of22
'Exelon Generation Company, L.L.C.
300 Exelon Way Kennett Square, PA 19348 Commercial Service Date March 10, 1973 Quad Cities Nuclear Power Station Unit 2 22710 2 0 6th Avenue North, Cordova, IL 61242 Table 3.1-1 (Expanded Scope and IWF-2220(b))
Quad Cities Unit 2 ASME Section XI Outage Scope (4 th Interval)
Report Number Component Class Category Item Inspection Results 2QR19-136 1010-W-204 2
F-A F1.20 VT-3 NRI-Expanded Scope 2QR19-137 I010-M-202 2
F-A F1.20 VT-3 NRI-Expanded Scope 2QR19-138 1010-W-206 2
F-A F1.20 VT-3 NRI-Expanded Scope 2QR19-143 1010-M-205 2
F-A F1.20 VT-3 NRI-Expanded Scope 2QR19-140 1086-M-203 2
F-A F1.20 VT-3 NRI-Expanded Scope 2QR19-141 1086-M-203.1 2
F-A F1.20 VT-3 NRI-Expanded Scope 2QR19-002 2305-M-2104 2
F-A FI. 10 VT-3 NRI-Follow Up Exam 2QR19-010 1012A-M-105 I
F-A F1 10 VT-3 NRI-Follow Up Exam Table 3.1-1A Quad Cities Unit 2 ASME Section XI Limited Coverage Summary (4h Interval)
Report Number Component Class Category Item Inspection ASME % Coverage 2QR19-092 RPV-THHF I
B-A B1.40 UT 67.2%
2QR19-067 N3B NOZ I
B-D B3.90 UT 40.80%
2QR19-083 N3D NOZ I
B-D B3.90 UT 40.80%
2QR19-093 N5A NOZ I
B-D B3.90 UT 43.10%
2QR19-122 N5B NOZ I
B-D B3.90 UT 43.10%
2QR19-095 N6A NOZ I
B-D B3.90 UT 63.30%
2QR19-098 N6B NOZ I
B-D B3.90 UT 63.30%
2QR19-084 N7 NOZ I
B-D B3.90 UT 82.50%
2QR19-120 N9 NOZ I
B-D B3.90 UT 77.50%
NOTE:
These welds were limited during the 3rd interval and were granted relief under Exelon Relief Request CR-CR-32, CR-35, and CR-39. Coverage was equal or greater under new examination.
12 of 22
'Exelon Generation Company, L.L.C.
300 Exelon Way Kennett Square, PA 19348 Commercial Service Date March 10, 1973 Quad Cities Nuclear Power Station Unit 2 22710 2 0 6th Avenue North, Cordova, IL 61242 Table 3.1-2 Quad Cities Unit 2 Pressure esting Summary (4th Interval)
Component Inspection Category Item Procedure/
Relief Remarks Number Report Request RX, Class and B15.10, QCOS 0201-08 Class I & 2 Class 2 Visual, VT-2 B-P 15.50, 15.60, 14R-07 System leakage Class 2 170 VT Report VT2-116 Ts 15.70 Test NIO IRS Visual, VT-2 B-D B3.100 QCOS 0201-08 14R-01 Class I System VT Report VT2-116 leakage Test QCOS 001-08Obstructed, 1025-48 Visual, VT-2 C-B C2.33 QCOS 020108 inspectleakage VT Report VT2-1 16 syspetlem kg system 1025-52 Visual, VT-2 C-B C2.33 QCOS 0201-08 binspectleakage VT Report VT2-1 16 syspetlem kg system QCOS 0201-08 Obstructed, 1025-56 Visual, VT-2 C-B C2.33 VT Report VT2-1 16 inspect leakage system 1025-60 Visual, VT-2 C-B C2.33 QCOS 0201-08 Obstructed, VT Report VT2-116 inspect leakage system 0209A-FI0 Visual, VT-2 R-A R1.20 QCOS 0201-08 14R-02 RI-SI Socket VT Report VT2-116 Weld 0209A-FI6 Visual, VT-2 R-A RI.20 QCOS 0201-08 14R-02 RI-IS! Socket VT Report VT2-116 Weld 0209A-F4 Visual VT-2 R-A R1.20 QCOS 0201-08 14R-02 RI-ISI Socket VT Report VT2-116 Weld 0209B-F2 Visual, VT-2 R-A R1.20 QCOS 0201-08 14R-02 RW-eSl Socket VT Report VT2-116 Weld 02091-F8 Visual, VT-2 R-A R1.20 QCOS 0201-08 14R-02 RI-IS! Socket VT Report VT2-116 Weld 1265-FI5R Visual, VT-2 R-A.
R1.20 QCOS 0201-08 14R-02 RI-IS! Socket VT Report VT2-116 Weld 1265-1716R Visual, VT-2 R-A R1.20 QCOS 0201-08 14R-02 RI-ISI Socket VT Report VT2-116 Weld Core Spray Visual, VT-2 B-P B15.50, 15.70 QCOS 0201-08 14R-07 Class I System Class I VT Report VT2-116 leakage Test RHR Class I Visual, VT-2 B-P B 15.50, 15.70 QCOS 0201-08 14R-07 Class I System VT Report VT2-116 leakage Test Reactor Head Line 2-0236-1' Visual, VT-2 C-H C7.30, C7.70 System in Operation 14R-05 Flange Seal Leak and 2-0234-I" VT Report VT2-1 13 DtcinSse Detection System CRD Visual, VT-2 C-H C7.10, C7.30, QCOS 0201-08 14R-06, 14R-Class 2 System C7.70 VT Report VT2-116 07 Leakage Test Partial Class 2 RHR' Visual, VT-2 C-H C730, C7.50, System in Operation 14R-07 System Leakage C7.70 VT2-NDE-024 Ts Test Partial Class 2 HPCI' Visual, VT-2 C-H C7. 750, QCTS 0762-08 14R-07 System Leakage C7.70 VReotVT2-12 17 14R-07 System Leakage Test C7.3, C.50, QCT 076-08Partial Class 2 SBLCt Visual, VT-2 C-H C7.307.0, QCTS Reor62-087 IR-07 System Leakage I77 VT ReotVT-1 Test Scram C7.l0, C7.30, QCOS 0201-08 Class 2 System Discharge Visual, VT-2 C-H C.7.70 VT Report VT2-1016 14R-07 Leakage Test Volume Note 1:
Only part of ASME Class 2 boundary completed. Remainder will be complete during the current inspection period.
13 of 22
'Exelon Generation Company, L.L.C.
300 Exelon Way Kennett Square, PA 19348 Commercial Service Date March 10, 1973 Quad Cities Nuclear Power Station Unit 2 22710 206th Avenue North, Cordova, IL 61242 Table 3.1-3 Quad Cities Unit 2 Snubber Functional Tests (4 th Interval)
Drawing Component T/S Number Class Category Item Inspection Date Results IR#
Tested M-1022D-268 0200-W-107 A&B 2-011 1
F-A F1.40 FT 3/6/2008 PASS NA M-1026D-311 1012A-W-102 2-006' 1
F-A FI.40 FT 3/14/2008 PASS NA M-1026D-319 1012B-W-101 2-008' 1
F-A FI.40 FT 3/14/2008 PASS NA M-1026D-312 1012B-W-102 2-007' 1
F-A FI.40 FT 3/11/2008 FAIL 00748230 M-1022D-9 1025-M-101 A&B 2-085' 1
F-A FI40 FT 3/11/2008 PASS NA Sht. 1, 3 M-1022D-9 1025-M-101 A&B 2-086' I
F-A FI.40 FT 3/11/2008 FAIL 00748218 Sht. 1,3 M-1022D-8 1025-M-102.1 A&B 2-083' 1
F-A F1.40 FT 3/11/2008 FAIL 00748206 Sht. 1,2,3 M-1022D-8 1025-M-102.1 A&B 2-084' 1
F-A FI.40 FT 3/11/2008 FAIL 00748210 Sht. 1,2,3 M-10251-17 1202-M-1 15 A&B 2-087 1
F-A F1.40 FT 3/6/2008 FAIL 00745564 Sht. 1,4 M-1025D-17 1202-M-1 15 A&B 2-088 1
F-A FI.40 FT 3/6/2008 FAIL 00745567 Sht. 1,4 M-1024D-7 1307-M-106 2-0422 1
F-A FI.40 FT 3/6/2008 PASS NA M-1016D-251 1403-W-103 A&B 2-001P 1
F-A FI40 FT 3/17/2008 PASS NA M-1016D-252 1403-W-103 A&B 2-002' 1
F-A F1.40 FT 3/17/2008 PASS NA M-328G 2305-M-101.1 2-077'2 1
F-A FI.40 FT 3/4/2008 PASS NA Sht. 9 M-328G 2305-M-101.2 2-076' I
F-A F1.40 FT 3/4/2008 PASS NA Sht. 8 M-328G 2305-M-102.1 2-078l2 1
F-A F1.40 FT 3/5/2008 PASS NA Sht. 22 M-10181-1123 0320-M-201 2-1421 2
F-A F1.20 FT 3/16/2008 PASS NA Sht. 1,2,3 M-1805-04 1015A-M-202 2-124 2
F-A F1.20 FT 2/28/2008 PASS NA M-1805-10 1015A-M-203 2-125' 2
F-A FI.20 FT 3/14/2008 PASS NA Sht. I M-1806-07 1015B-M-201.1 2-128' 2
F-A F1.20 FT 3/14/2008 PASS NA M-1806-04 1015B-M-203 A&B 2-126' 2
F-A F1.20 FT 3/15/2008 PASS NA M-1806-04 1015B-M-203 A&B 2-127' 2
F-A FI.20 FT 3/15/2008 PASS NA M-1805-02 1016A-M-201.1 A&B 2-122' 2
F-A FI.20 FT 3/15/2008 PASS NA Sht: 1, 2 M-1805-02 1016A-M-201.1 A&B 2-123 2
F-A F1.20 FT 2/28/2008 PASS NA Sht. 1, 2 M-1806-12 1016C-M-201.1 2-144' 2
F-A F1.20 FT 3/15/2008 PASS NA Sht. 1,2 M-1802-26 1025-M-201 2-102' 2
F-A F1.20 FT 3/13/2008 PASS NA Sht. 1, 2 M-1802-06 1025-M-203 2-103 2
F-A FI.20 FT 2/27/2008 FAIL 00741597 Sht. 1, 2 M-1802-27 1025-M-205 2-104' 2
F-A F1.20 FT 3/13/2008 PASS NA Sht. 1,2 M-1802-25 1025-M-222 2-099 2
F-A F1.20 FT 2/26/2008 PASS NA Sht. 1,2 M-1017D-59 2305-M-207 2-1202 2
F-A FI.20 FT 3/5/2008 PASS NA 14 of 22
Exelon Generation Company, L.L.C.
300 Exelon Way Kennett Square, PA 19348 Commercial Service Date March 10, 1973 Quad Cities Nuclear Power Station Unit 2 22710 2 0 6th Avenue North, Cordova, IL 61242 Table 3.1-3 Quad Cities Unit 2 Snubber Functional Tests (4th Interval)
Drawing Component T/S Number Class Category Item Inspection Date Results JR#
Tested M-1813-04 2306-M-205.1 2-133 2
F-A FI.20 FT 2/28/2008 PASS NA Sht. 1, 2 M-1813-02 N/A 2-132 NA NA NA FT 2/27/2008 PASS NA Sht. 1, 2 M-1807-08 N/A 2-107 NA NA NA FT 2/26/2008 PASS NA Sht. 1, 2 M-1807-09 N/A 2-108 NA NA NA FT 2/27/2008 PASS NA Sht. 1,2 1
1 M-1834 N/A 2-136' NA NA NA FT 3/14/2008 PASS NA M-1984 N/A 2-137' NA NA NA FT 3/15/2008 PASS NA M-1018D-1022 N/A 2-141' NA NA NA FT 3/16/2008 PASS NA M-3298 NA 2-027 NA NA NA FT 3/4/2008 PASS NA Sht. 7 M-1053-BG NA 2-030' NA NA NA FT 3/15/2008 PASS NA Sht. 1, 4 M-1053-BG NA 2-031 '
NA NA NA FT 3/15/2008 PASS NA Sht. 1,4 M-1053-BF NA 2-032' NA NA NA FT 3/15/2008 FAIL 00750102 Sht. 1, 4-M-1053-BF NA 2-033' NA
- NA NA FT 3/I 5/2008 PASS NA Sht. 1,4 M-1026D-93 NA 2-036' NA NA NA FT 3/15/2008 PASS NA M-1026D-7 NA 2-051' NA NA NA FT 3/15/2008 PASS NA M-328E NA 2-060 NA NA NA FT 3/6/2008 PASS NA Sht. 10 M-328H NA 2-074 NA NA NA FT 3/4/2008 PASS NA Sht. 5 L
I I
NOTE: These snubbers were tested as part of the expanded sample testing as a result of functional test failures.
2 NOTE: These snubbers were replaced as part of service life monitoring.
15 of 22
Exelon Generation Company, L.L.C.
300 Exelon Way Kennett Square, PA 19348 Commercial Service Date March 10, 1973 Quad Cities Nuclear Power Station Unit 2 22710 2 0 6th Avenue North, Cordova, IL 61242 Table 3.1-4 Quad Cities Unit 2 Conditions Noted on ASME Code Components and Corrective Actions (4 Interval)
Component ID Description / Resolution Pressure Test During the Unit 2 Class I Leakage Test the listed components were identified to be leaking.
Corrective actions were taken as follows:
Corrective actions completed "B" Recirculation Pump Flange.
Engineering evaluation (EC # 0000335753) was performed (as permitted by Relief Request 14R-07) on the 2B Recirculation Pump and determined the leakage to be acceptable. No change since last outage.
Reference VT report # VT2-116 dated 03/21/08 2-0220-1 0
Issue Report 752544, Repaired Seal Ring 2-1001-28A 0
Issue Report 752553, Repaired Packing Reference EC 0000359753 is still applicable for evaluating Leakage Observed Report VT2-116 on South Bank HCU 14-07-114, 18-55-104, and North Bank HCU 34-55-114 as materials and conditions are still the same.
Visual Inspections Torus Bays 3, 6, and 16 As a result of inspections in accordance with ASME Section XI IWE 1992 Edition, 1992 Addenda VT-3 was performed under Work Order 1004253 for remaining portions of Unit 2 containment structures. Indications were identified in Bay 3 (IR 00748868), Bay 6 (IR 00748405), and Bay 16 (IR 00749065) that were acceptable per previous evaluation but require subsequent VT-i examination. The indications were mechanical damage prior to initial painting that had not been previously documented.
Hanger 1086-M-202 Loose nuts found on hanger anchor plate that had not been previously documented. IR 00743311 assigned WO 01111174 to correct (acceptance VT-3 Report NDE-094) and subsequent scope expansion. Expansion was complete with no additional issues.
Hanger 1010-M-203 Spring can out of tolerance was identified under IR 00743307 and-corrected under WO 01110676 (acceptance VT-3 Report VT3-081) and subsequent scope expansion. Expansion was complete with no additional issues.
Snubber Functional Tests 1012B-W-102 Snubber failed functional test and was replaced. (IR 00748230) 1025-M-101 A&B One snubber of a tandem set failed functional test and was replaced. (IR 00748218) 1025-M-102.1 A&B Both snubbers of a tandem set failed functional tests and were replaced. (IR 00748206 and 00748210) 1202-M-1 15 A&B Both snubbers of a tandem set failed functional tests and were replaced. (IR 00745564 and 00745567) 1025-M-203 Snubber failed functional test and was replaced. (IR 00741597) 16 of 22
Exelon Generation Company, L.L.C.
300 Exelon Way Kennett Square, PA 19348 Commercial Service Date March 10, 1973 Quad Cities Nuclear Power Station Unit 2 22710 2 0 6th Avenue North, Cordova, IL 61242 Table 3.1-4 (continued)
Quad Cities Unit 2 Conditions Noted on ASME Code Components and Corrective Actions (4'h Interval)
Component ID Description / Resolution In Vessel Inspections Feedwater Sparger End Brackets Inspected the eight Feedwater Sparger End Bracket surfaces for evidence of wear.
Seven of the eight brackets showed evidence of wear similar to that observed during Q2R18. This is not a concern for the immediate future. The worst worn bracket still has greater than 90% of its original thickness remaining. Quad Cities will continue to monitor this condition. Indications to non-code areas were documented in IR's 00746384, 00746392, and 00748013 and accepted in EC 369931.
Steam Dryer Wall Support Lugs Follow-up inspections of previous indications to determine extent of condition were performed on the steam dryer wall support lugs. No additional damage was observed except for normal wear. Indications in non-code areas were documented in IR 00748544 and accepted in EC 369931.
Jet Pump #17 An auxiliary wedge was installed on the second of two restrainer bracket setscrews on Jet Pump # 17 to take up a 0.041" gap between the setscrew and the jet pump barrel. This was a proactive measure to minimize vibration of the jet pump assembly. Jet Pump #17 already had an auxiliary wedge on the other setscrew. This was documented in IR 00746799 and installed under EC 369869. The Jet Pump is a non-code component.
17 of 22
'Exelon Generation Company, L.L.C.
300 Exelon Way Kennett Square, PA 19348 Commercial Service Date March 10, 1973 Quad Cities Nuclear Power Station Unit 2 22710 2 0 6 th Avenue North, Cordova, IL 61242 Table 3.2-1 Quad Cities Unit 2 BWRVIP-75-A/GL 88-01 Outage Scope Report Number Component Class Pre/Post Outage Inspection Results Category 2QR19-017 IOBD-S2 I
C UT NRI 18 of 22
'Exelon Generation Company, L.L.C.
300 Exelon Way Kennett Square, PA 19348 Commercial Service Date March 10, 1973 Quad Cities Nuclear Power Station Unit 2 22710 2 0 6 'h Avenue North, Cordova, IL 61242 Table 3.3 Quad Cities Unit 2 Number and Percentage of Examinations Completed (4 th Interval)
Category Exams Completed in Q2R19 Exams Completed to Date Total Exams in the Interval Percentage Complete for Interval B-A 4 1
16 23 70 B-D 19 39 58 67 B-G-I' 5
10 6
Not Applicable B-G-27 7
12 18 67 B-K 2
6 9
67 B-L-2' Not Applicable Not Applicable Not Applicable Not Applicable B-M-25 1
2 2
100 B-N-1 2 1
1 I
100 B-N-2 2 0
1 1
100 B-0 4 0
0 2
0 B-P 3 I
I 1
100 C-A 1
2 4
50 C-B 6 6
14 14 100 C-C 3
6 10 60 C-H3 I
1 1
100 F-A 8 22 52 87 60 R-A 35 59 103 57
'Note:
Category B-G-1 is for reactor vessel studs and nuts. Items in this category are repeated each period and may result in greater than the limiting percentage of exams. The studs and their corresponding locations are divided by approximately 1/3 per period to allow for distribution of the component across ten year interval.
2Note:
Category B-N-I are inspected each period in accordance with the IVVI program. 100% Category B-N-2 were inspected in the first period.
3Note:
Category B-P and C-H exams are tracked under Table 3.1-2.
4Note:
Exam Category B-A and B-O are scheduled to coincide with previous interval to maintain ten year interval between exams and are performed in accordance with 10CFR50.55a. Period completion percentage does not apply.
5Note:
Categories B-L-2, and B-M-2 are inspected and credited under the Repair/Replacement Program only when
- the component is disassembled.
6Note:
Categories C-B components are examined during the performance of the system pressure test each inspection period and can result in greater than the limiting percentage of exams.
7Note:
Categories B-G-2 Item B7.70 components are examined in conjunction with Category B-M-2 or B-L-2 exams. Therefore, only item B7.50 can be tracked for distribution by this category.
8Note:
F-A Category includes only Class 1 and 2 components in Items F1.10, F1.20, and F1.40.
19 of 22
Exelon Generation Company, L.L.C.
300 Exelon Way Kennett Square, PA 19348 Commercial Service Date March 10, 1973 4.0 Repair / Replacement Summary 4.1 NIS-2 Index Quad Cities Nuclear Power Station Unit 2 22710 2 0 6 th Avenue North, Cordova, IL 61242 Table 4.1-1 Quad Cities Unit 2 NIS-2 List Program Number Component EPN Work Request Number ASME XI Class or Purchase Order 02-074 0-Spare-V18 00410491-02 1
05-082 2-1402-8A 00688962-01 2
06-031 2-3001-C67 00885636-01 1
06-047,08-041 2-0203-IA 00827238-01 1
06-074 2-0220-62A 00672336-01 1
06-075 2-1001-125A 00832684-01 2
06-130 2-1402-28A 00879818-01 2
06-145 2-0203-3A 00955891-01 1
07-006 2-1001-22A 00948625-01 2
07-012 2-2301-51 00976567-01 2
07-023,08-038 2-1103 00986548-01,05 2
07-049,08-025 2-0220-2 00910412-01, 12 2
07-055 2-2301-3 01034761-01 2
07-064 2-2305-120 01012233-01 2
07-065 2-2305-77 01012229-01 1
07-066 2-2305-76 01012224-01 1
07-067 2-2305-78 01012231-01 2
07-069,08-024, 2-0220-1 01002228-01, 13, 16 2
08-055 07-070 2-1307-42 01012223-01 1
07-075,07-086 2-1106-B 00954420-02, 03 2
07-076 2-0203-4C 00949147-01 1
07-077 2-0203-4D 00949148-01 1
07-078 2-0203-4G 00949149-01 1
07-079 2-0203-4H 00949150-01 1
07-080 2-0203-3D 00949146-01 1
07-081 2-0203-4A 01041555-01 1
07-091 2-0203-3C 00837563-01 1
07-097 2-0220-58B 00953365-01 1
08-004 through Various Control Rod 00912799 1
08-023 Drives08-028, 08-029 Spare PO 420577 1
08-033 Spare PO 420577 1
08-036 2-1025-103 01012200-01 2
08-040 2-1025-20"-A 01040755-01 1
08-042 2-1025-83 01112317-01 1
08-043 2-1025-85 01112323-01 1
08-044 2-1025-86 01112324-01 1
08-045 2-1012-B7 01112311-01 1
08-046 2-1025-84 01112322-01 1
08-047 2-1202-88 01012216-01 1
20 of22
'Exelon Generation Company, L.L.C.
300 Exelon Way Kennett Square, PA 19348 Commercial Service Date March 10, 1973 Quad Cities Nuclear Power Station Unit 2 22710 2 0 6th Avenue North, Cordova, IL 61242 Table 4.1-1 Quad Cities Unit 2 NIS-2 List Program Number Component EPN Work Request Number ASME XI Class or Purchase Order 08-048 2-1202-87 01012213-01 1
08-050 2-2305 00880548-01 2
08-052,08-053 2-1001-125D 00949152-07, 04 2
21 of 22
Exelon Generation Company, L.L.C.
300 Exelon Way Kennett Square, PA 19348 Commercial Service Date March 10, 1973 4.2 NIS-2 Forms (Attached)
Quad Cities Nuclear Power Station Unit 2 22710 206'h Avenue North, Cordova, IL 61242 22 of22
4.
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI I. Owner:
Exelon Generation Company, LLC 4300 Winfield Road Warrenville, I1. 60555 2.Plant:
Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242
- 3. Work Performed by:
Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 Date:
3/3/2006 Sheet:
I of I Unit:
0 Program No.02-074 WO 00410491-02 Repair Organization P.O. No.. Job No., etc.
Type Code Symbol Stamp:
None Authorization No.:
None Expiration Date:
N/A
- 4. Identification of System: Feedwater, Class I (Spare)
- 5. (a) Applicable Construction Code: USAS B3 1.1 1967 Edition, None Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
1989 Edition, None Addenda, N/A Code Case
- 6. Identification of Components Repaired or Replaced, and Replacement Components:
Name of Name of Mfrs. Ser.
Nat'[
Other Year
- Repaired, ASME Component Mfr.
No.
Bd.
Identification Built Replaced, or Code No.
Replacement Stamped (Yes or No)
Check Valve Crane N/A N/A 0-spare-V 18 N/A Repaired No
- 7. Description of Work: Repaired valve disc by replacing hardfacing in accordance with the WO.
- 8. Tests Conducted:
Hydrostatic El Pneumatic E]
Nominal Operating Pressure El Other E]
Pressure psi Test Temp.
'F
- 9. Remarks: None.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this repair conforms to the rules of ASME Code, Section Xl Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No.
N/A Expiration Date N/A Signed
,W.D It'4 4-200(o V
Owner or Owners'Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois
, and employed by HSB CT. of Connecticut have inspected the components described in this Owner's Report during the period
/JI/4','/O,'" to.4lZI/o0
, and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code, Section Xl.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or
- 7.
o rtydamage or a loss of any kind arising from or connected with this inspection.
Ipe cN inal Board. Stme. Province.
and En-ko
_emenis Date
- A Z20
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI
- 1. Owner:
Exelon Generation Company, LLC 4300 Winfield Road Warrenville, Ii. 60555 2.Plant:
Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242
- 3. Work Performed by:
Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 Date:
04/15/2008 Sheet:
I of 1 Unit:
2 Program No.05-082 WO 688962-01 Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp:
Authorization No.:
Expiration Date:
None None N/A
- 4. Identification of System:
Core Spray, Class 2
- 5. (a) Applicable Construction Code:
USAS B31.1 1967
- Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
1995 Edition, 1996 Addenda, N/A Code Case
- 6. Identification of Co ponents Repaired or Re laced, and R placement Components:
Name of Name of Mfrs. Ser.
Nat'l Other Year
- Repaired, ASME Component Mfr.
No.
Bd.
Identification Built Replaced, or Code No.
Replacement Stamped (Yes or No)
Valve Exelon N/A N/A 2-1402-8A N/A Replacement No
- 7. Description of Work: Machined valve body in accordance with WO.
- 8. Tests Conducted:
Hydrostatic E] " Pneumatic E]
Nominal Operating Pressure El Exempt [
Other El Pressure psi Test Temp.__ OF
- 9. Remarks: None.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this replacement conforms to the rules of ASME Code,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No.
N/A Expiration Date N/A Signed r"wt /,5/
1,.32,
/,S Date
,,4/'e/
/(
20 0 Owner of'Owner" Designee, TMtle CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois
, and employed by HSB CT. of Hartford. Connecticut have inspected the components described in this Owner's Report during the period a//5 to
, and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code, Section Xl.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
(224',/
Commissions
/L 5-.--
lnsp&1t0ý'*natnre -
National Board, State. Province, and Endorsements Date 6't2/t.d
,l2 20 09g
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME'Code Section XI."
- 1. Owner:
Exelon Generation Company, LLC 4300 Winfield Road, Warreriville, I1. 60555 2.Plant:
Quad Cities Generating Station 227 10206th Ave. North, Cordova, IL.61242 3'. Work Performed by:
Quad Cities Generating Station
.22710 206th Ave. North, Cordova, IL 61242 Date:
04/17/2007 Sheet:
1 ofl Unit:
2 Program No.06-031 WO 00885636-01 Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp:
None Authorization No.:
None Expiration Date:
N/A
- 4. Identification of System:
Main Steam, Class 1
'5.'(a) Applicable Construction Code: USAS B31.t 1967; ASME Section 1 1965 Edition, N/A, Summer 1966 Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
1995 Edition, 1996 Addenda, N/A Code Case
- 6. Identification of Components Repaired or Replaced, and Replacement Components:
Name of.
Nameof Mfrs-Ser.
Nat'l Other:
Year
- Repaired, ASME Component Mfr."
No.
Bd.
Identification Built Replaced, or Code No.
Replacement Stamped (Yes or No)
.:."HYDRAULIC LISEGA 61,310-31 N/A 2-3001-C67' N/A Replacement No' SNUBBER Replacemet
- 8. Tests Conducted:
Hydrostatic 0l Pneumatic El Nominal Operating Pressure El Exempt 0 Other El:
Pressure psi Test Temp.
'F
- 9. Remarks: None.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this replacement conforms to the rules of ASME Code,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization NO.
N/A Expiration Date N/A Signed
$,,i,n-Date I2007 V vheorUnf ageeTil CERTIFICATE OF INSERVICE INSPECTION I,- the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois
, and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period to and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code, Section Xl.
,By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
11 J 1ll W
Commissions 1i L /,59 Iimpe>A~/~~atutf 6
4/,-)
National Board, State, Ptuvince. and Endorsements Date 9n
- "7 Dlate 20 Q-
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI
- 1. Owner:
Exelon Generation Company, LLC 4300 Winfield Road Warrenville, 11. 60555 2.Plant:
Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242
- 3. Work Performed by:
Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 Date:
04/16/2008 Sheet:
I of I Unit:
2 Program No.06-047, 08-041 WO 827238-01 Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp:
Authorization No.:
Expiration Date:
None None N/A
- 4. Identification of System:
Main Steam, Class 1
- 5. (a) Applicable Construction Code:
ASA B31.1 1955
- Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
1995 Edition, 1996 Addenda, N/A Code Case
- 6. Identification of Components Repaired or Replaced, and Replacement Components:
Name of Name of Mfrs. Ser.
Nat'l Other Year
- Repaired, ASME Component Mfr.
No.
Bd.
Identification Built Replaced, or Code No.
Replacement Stamped (Yes or No)
Main Steam Exelon N/A N/A 2-0203-I A N/A Replacement No Isolation Valve
- 7. Description of Work: Replaced plug assembly and drilled anti-rotation holes in accordance with WO.
- 8. Tests Conducted:
Hydrostatic E]
Pneumatic E[
Nominal Operating Pressure E]
Exempt Z Other LI Pressure __
psi Test Temp.
'F
- 9. Remarks: None.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this replacement conforms to the rules of ASME Code,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No.
N/A Expiration Date N/A Signed o
4
,/
5!
Date 4
,'I
/
20 09 Owner or Owner's 'Designee Tited CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois
, and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period 2?/ -7 to I/z67..!a?
, and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
Commissions
,L
.2159 n~p&u/~S~nMure
~
I.-
National Board, State, Province, and Endorsements Date 20 Og Dacte 20o Q-f
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI
- 1. Owner:
Exelon Generation Company, LLC 4300 Winfield Road Warrenville, 11. 60555 2.Plant:
Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242
- 3. Work Performed by:
Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 Date:
04/15/2008 Sheet:
I of I Unit:
2 Program No.06-074 WO 672336-01 Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp:
Authorization No.:
Expiration Date:
None None N/A
- 4. Identification of System:
Feedwater, Class 1
- 5. (a) Applicable Construction Code:
USAS B31.1 1967
- Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
1995 Edition, 1996 Addenda, N/A Code Case
- 6. Identification of Components Repaired or Replaced, and Replacement Components:
Name of Name of Mfrs. Ser.
Nat'l Other Year
- Repaired, ASME Component Mfr.
No.
Bd.
Identification Built Replaced, or Code No.
Replacement Stamped (Yes or No)
Feedwater Check Exelon N/A N/A 2-0220-62A N/A Replacement No Valve I
I
- 7. Description of Work: Replaced Trim Set in accordance with WO.
- 8. Tests Conducted:
Hydrostatic 0 Pneumatic El Nominal Operating Pressure El Exempt Z Other E1 Pressure __
psi Test Temp.
F
- 9. Remarks: LLRT performed.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this replacement conforms to the rules of ASME Code,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No.
N/A Expiration Date C"
N/A Signed
=ýZ
ý
'X
/Si Date 20
/
f Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois
, and employed by HSB CT. of Hartford. Connecticut have inspected the components described in this Owner's Report during the period t
, and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures descriled in this Owner's Report in accordance the requirements of the ASME Code,Section XI.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
('1, //
~Commissions tt5 Inspectors )"a National Board, State, Province, and Endorsements Date A
,?..-
20 _L_
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI
- 1. Owner:
Exelon Generation Company, LLC 4300 Winfield Road Warrenville, 11. 60555 2.Plant:
Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242
- 3. Work Performed by:
Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 Date:
6/28/2006 Sheet:
I of I Unit:
2 Program No.06-075 WO 00832684-01 Repair Organization P.O. No.. Job No.. etc.
Type Code Symbol Stamp:
None Authorization No.:
None Expiration Date:
N/A
- 4. Identification of System: Residual Heat Removal, Class 2
- 5. (a) Applicable Construction Code: USAS B3 1.1 1967 Editions, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
1995 Edition, 1996 Addenda, N-416-3 Code Case
- 6. Identification of Components Repaired or Replaced, and Replacement Components:
Name of Name of Mfrs. Ser.
Nat'l Other Year
- Repaired, ASME Component Mfr.
No.
Bd.
Identification Built Replaced, or Code No.
Replacement Stamped (Yes or No)
Relief Valve CONSOLIDATED TP-34857 N/A 2-1001-1 25A N/A Replacement Yes I
VALVE CORP
- 7. Description of Work: Replaced valve, flange, and bolting in accordance with the W.O.
- 8. Tests Conducted:
Hydrostatic El Pneumatic [I Nominal Operating Pressure 1 Other E]
Pressure __
psi Test Temp.-_ 'F
- 9. Remarks:
None.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this replacement conforms to the rules of ASME Code,Section XI repai or replacement Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 Avg B. 0 A Program Certificate of Authorization No.
N/A Expiration Date N/A Signed gA
&,-. 6vpRg%
Date
%J',LV 3 2006,P V
OQ*ner or Owner's Degignee, ritule CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of -r
, and employed by HSB CT. of Connecticut have inspected the components described in this Owner's Report during the period to
, and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code, Section Xl.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore. neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
SCommissions 12.1 A AId Naiwioal Board. Stme. Province. and Endorsmenes Date 20
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Codc Section XI I. Owner:
Exelon Generation Company, LLC 4300 Winfield Road Warrenville, 11. 60555 2.Plant:
Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242
- 3. Work Performed by:
Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 Date:
10/31/2006 Sheet:
I of I Unit:
2 Program No.06-130 WO 00879818-01 Repair Organization P.O. No.. Job No., etc.
Type Code Symbol Stamp:
None Authorization No.:
None Expiration Date:
N/A
- 4. Identification of System:
Core Spray, Class 2
- 5. (a) Applicable Construction Code: USAS B31.1 1967 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
1995 Edition, 1996 Addenda, N/A Code Case
- 6. Identification of Components Repaired or Replaced, and Re placement Components:
Name of Name of Mfrs. Ser.
Nat'l Other Year
- Repaired, ASME Component Mfr.
No.
Bd.
Identification Built Replaced, or Code No.
Replacement Stamped (Yes or No)
Relief Valve Consolidated TL76483 N/A 2-1402-28A N/A Replacement No I__ _ _ _
Dresser I
I 1
1
- 7. Description of Work: Replaced the relief valve in accordance with W.O.
- 8. Tests Conducted:
Hydrostatic 0 Pneumatic El Nominal Operating Pressure [
Exempt C
'Other C Pressure psi Test Temp.__
F
- 9. Remarks:
None.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this replacement conforms to the rules of ASME Code,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. Q A Program Certificate of Authorization No.
N/A Expiration Date N/A Signed A
1,\\1 P-
,r si 'vp "
Date VDc e,
'r 20C&X U
-OnerbrOwiers DesigteeTitte CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois
, and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period
./1/44.
to I
and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective easures described in this Owner's Report in accordance the requirements of the ASME Code, Section Xl.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
/1/,
Commissions IL
-,215 irs inatur NuZlamil Board. Stalo. Pravjnce.
and bidm emesnnts Date I,/A 20
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI
- 1. Owner:
Exelon Generation Company, LLC 4300 Winfield Road Warrenville, Ii. 60555 2.Plant:
Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242
- 3. Work Performed by:
Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 Date:
04/04/2008 Sheet:
I of I Unit:
2 Program No.06-145 WO 955891-01 Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp:
Authorization No.:
Expiration Date:
None None N/A
- 4. Identification of System:
Main Steam, Class 1
- 5. (a) Applicable Construction Code:
ASME Section Ill 1965/1968 ED.
- Edition, Winter 1968 Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
1995 Edition, 1996 Addenda, N/A Code Case
- 6. Identification of Cop onents Repaired or Replaced, and Replacement Components:
Name of Name of Mfrs. Ser.
Nat'l Other Year
- Repaired, ASME Component Mfr.
No.
Bd.
Identification Built Replaced, or Code No.
Replacement Stamped (Yes or No)
Target Rock Relief Target Rock Corp.
171 N/A 2-0203-3A N/A Replaced No
- 7. Description of Work: Replaced Target Rock Relief Valve in accordance with WO.
- 8. Tests Conducted:
Hydrostatic EL Pneumatic 0l Nominal Operating Pressure 0 Exempt El Other El Pressure _
psi Test Temp._ IF
- 9. Remarks: None.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this replacement conforms to the rules of ASME Code,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No.
N/A Expiration Date N/A Signed 1-%*7" Z5/*,,
Date
.46,,
/
/S 20 0 g Owner or Owner's Ddsignee, Title d
I CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois
, and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period 10/!/o/o (,,
to "
and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
A/-/
-Commissions
'1.
/
,, /--
lnsorto/*nature National Board, State, Province. and Endorsements D ate 20 o s-
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI
- 1. Owner:
Exelon Generation Company, LLC 4300 Winfield Road Warrenville, I1. 60555 2.Plant:
Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242
- 3. Work Performed by:
Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 Date:
12/10/2007 Sheet:
I of I Unit:
2 Program No.07-006 WO 948625-01 Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp:
Authorization No.:
Expiration Date:
None None N/A
- 4. Identification of System:
Residual Heat Removal, Class 2
- 5. (a) Applicable Construction Code:
USAS B3 1.1 1967
- Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
1995 Edition, 1996 Addenda, N/A Code Case
- 6. Identification of Com oonents Repaired or Replaced, and R placement Components:
Name of Name of Mfrs. Ser.
Nat'i Other Year
- Repaired, ASME Component Mfr.
No.
Bd.
Identification Built Replaced, or Code No.
Replacement Stamped (Yes or No)
Relief Valve Consolidated N/A N/A 2-1001-22A N/A Replacement No Kinetics Corporation
- 7. Description of Work: Replaced bolting in accordance with WO.
- 8. Tests Conducted:
Hydrostatic El Pneumatic F1 Nominal Operating Pressure El Exempt [
Other E]
Pressure psi Test Temp.
'F
- 9. Remarks: None.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this replacement conforms to the rules of ASME Code, Section Xl Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No.
N/A Expiration Date N/A Signed S*
j 44",
- ,*,c*
4,v.,r Date toe C-*
/,
2007 V
Owner of Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois
, and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period Z9,, -.
to i/
/,:2
, and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
L,1,_,_
Commissions
/ L Ir g~s Sigiaature
/Natkinal Board. State, Province, and Endo..ements JDate A, ý 20 t") -1
-' 4, FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section'XI
.1. Owner:
Exelon Generation Company, LLC 4300 Winfield Road Warreriville, Ii. 60555, 2.Plant:,
Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242
- 3. Work Performed by:
Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 Date:
02/23/2007 Sheet:
I of I Unit:
2 Program No.07-012 WO 976567-01 Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp:
Authorization No.:
Expiration Date:
None None N/A
- 4. identification of System:
High Pressure Coolant Injection, Class 2
- 5. (a) Applicable Construction Code: USAS B331.1 1967 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
1995 Edition, 1996 Addenda, N/A Code Case
- 6. Identification of Components Repaired or Replaced, and Replacement Components:
Name of Name of Mfrs. Ser.
Nat'l Other Year
- Repaired, ASME Component Mfr.
No.
Bd.
Identification Built Replaced, or Code No.
Replacement Stamped (Yes or Check Valve Crane N/A N/A 2-2301-51 N/A Replacement No
- 7. Description of Work: Replaced check valve in accordance with WO.
- 8. Tests Conducted:
Hydrostatic El Pneumatic El Nominal Operating Pressure Z Exempt E]
Other El Pressure psi Test Temp._ 'F
- 9. Remarks: None.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this replacement conforms to the rules of ASME Code,Section XI Type of Code Symbol Stamp' N/A - Exelon Nuclear IOCFR50 App B. ( A Program Certificate of Authorization No.
N/A Expiration Date N/A Signed
,itu, Date 4Av*,k L'
20 07
\\Z1 Oivner cfr Owner's Dlesignee,rTitle I
CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period Z/,
!2 to X
/
PŽa, 2o and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
/-i~
gI 44-A
(
4
-- "-~
AJII111331UI3 E
l2#Teg ignatnre J
National Board, State. Province, and Endorsements Date a J2
'7 20 (3 "
20 A
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI
- 1. Owner:
Exelon Generation Company, LLC 4300 Winfield Road Warrenville, I. 60555 2.Plant:
Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242
- 3. Work Performed by:
Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 Date:
04/21/2008 Sheet:
I of I Unit:
2 Program No.07-023, 08-038 WO 986548-01,05 Repair Organization PO. No., Job No., etc.
Type Code Symbol Stamp:
Authorization No.:
Expiration Date:
None None N/A
- 4. Identification of System:
Standby Liquid Control, Class 2
- 5. (a) Applicable Construction Code:
API 650 1966 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
1995 Edition, 1996 Addenda, N/A Code Case
- 6. Identification of Components Repaired or Re laced, and Replacement Components:
Name of Name of Mfrs. Ser.
Nat'l Other Year
- Repaired, ASME Component Mfr.
No.
Bd.
Identification Built Replaced, or Code No.
Replacement Stamped (Yes or No)
Standby Liquid Bethlehem Steel N/A N/A 2-1103 N/A Replacement No ControlTank
- 7. Description of Work: Replace support legs in accordance with WO.
- 8. Tests Conducted:
Hydrostatic El Pneumatic El Nominal Operating Pressure E]
Exempt S Other E]
Pressure psi Test Temp.
'F
- 9. Remarks: None.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this replacement conforms to the rules of ASME Code,Section XI Type of Code Symbol Stamp N/A-Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No.
N/A Expiration Date N/A Signed
-A0ZP 4 e* c i /SI 6,,i,*'f4Date 1r?/ ?1 200 L.
Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois
, apdgmployed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period Z6l to A,/y/
(Y and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
_Commissions iL
- l, z-9 Inspl-to
- nature National Board. State, PrTvince. and Endorsements l*te
- o o o° ADa~te 20 09
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI
- 1. Owner:
Exelon Generation Company, LLC 4300 Winfield Road Warrenville, I1. 60555 2.Plant:
Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242
- 3. Work Performed by:
Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 Date:
04/16/2008 Sheet:
1 of I Unit:
2 Program No.07-049, 08-025 WO 910412-01, 12 Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp:
Authorization No.:
Expiration Date:
None None N/A
- 4. Identification of System:
Main Steam, Class 2
- 5. (a) Applicable Construction Code:
USAS B31.1 1967
- Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
1995 Edition, 1996 Addenda, N-416-3 Code Case
- 6. Identification of Com ponents Repaired or Replaced, and Replacement Components:
Name of Name of Mfrs. Ser.
Nat'l Other Year
- Repaired, ASME Component Mfr.
No.
Bd.
Identification Built Replaced, or Code No.
Replacement Stamped (Yes or No)
Gate Valve Crane Company D6767 N/A 2-0220-2 N/A Replacement No
- 8. Tests Conducted:
Hydrostatic 0l Pneumatic Dl Nominal Operating Pressure ED Exempt El Other E]
Pressure psi Test Temp.
'F
- 9. Remarks: None.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this replacement conforms to the rules of ASME Code,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No.
N/A Expiration Date N/A Signed
-11)12,
..---,-'r---
.,* Date
,4~,-/
/&'
20 0 k
Owner or Owner's 1tDsignee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois
, and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period
--//,1Z//A9 to
=--/,
and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
62L~/'
Commissions Commissions L
Z
/ S1 ins ctokJýSllgnature flate 2Z,.
a/
National Board, State. Province. and Endorsements 20 6Of 5 20 61 k
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI
- 1. Owner:
Exelon Generation Company, LLC 4300 Winfield Road Warrenville, I1. 60555 2.Plant:
Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242
- 3. Work Performed by:
Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 Date:
04/25/2008 Sheet:
I of I Unit:
2 Program No.07-055 WO 103476 1-01 Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp:
Authorization No.:
Expiration Date:
None None N/A
- 4. Identification of System:
High Pressure Coolant Injection, Class 2
- 5. (a) Applicable Construction Code:
USAS B31.1 1967
- Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
1995 Edition, 1996 Addenda, N/A Code Case
- 6. Identification of Components Repaired or Replaced, and Re placement Components:
Name of Name of Mfrs. Ser.
Nat'l Other Year
- Repaired, ASME Component Mfr.
No.
Bd.
Identification Built Replaced, or Code No.
Replacement Stamped (Yes or No)
Valve Exelon N/A N/A 2-2301-3 N/A Repair No
- 7. Description of Work: Machined valve body in accordance with WO.
- 8. Tests Conducted:
Hydrostatic E]
Pneumatic El Nominal Operating Pressure [
Exempt Z Other E Pressure psi Test Temp.
OF
- 9. Remarks: None.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this repair conforms to the rules of ASME Code,Section XI Typeof Code Symbol Stamp N/A - Exelon Nuclear I OCFR50 App B. 0 A Program Certificate of Authorization No.
N/A Expiration Date N/A Signed 6ý_,.ke e4
.c-Date _
20_0__
Owner or Owner's DUesignee, Title -A CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois
, and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period Z
"2 to _
a
, and state that to the best of my knowledge and belief, the owner has performed examinations and taken correcti measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
Commissions
,L d/5-9 Ir..pec!c,9( 06tg~ure" National Board, State, Province. and Endorsements Date 20 Og Date 20 VS'
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI
- 1. Owner:
Exelon Generation Company, LLC 4300 Winfield Road Warrenville, I1. 60555 2.Plant:
Quad Cities Generating Station 22710 206th Ave. North, Cordova, EL 61242
- 3. Work Performed by:
Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 Date:
Sheet:
Unit:
04/07/2008 I of I 2
Program No.07-064 WO 1012233-01 Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp:
Authorization No.:
Expiration Date:
None None N/A
- 4. Identification of System:
High Pressure Coolant Injection, Class 2
- 5. (a) Applicable Construction Code:
USAS B31.1 1967
- Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
1995 Edition, 1996 Addenda, N/A Code Case
- 6. Identification of Components Repaired or Replaced, and Re placement Components:
Name of Name of Mfrs. Ser.
Nat'l Other Year
- Repaired, ASME Component Mfr.
No.
Bd.
Identification Built Replaced, or Code No.
Replacement Stamped (Yes or No)
Snubber Lisega 01615203 / 50 N/A 2-2305-120 N/A Replacement No
- 8. Tests Conducted:
Hydrostatic Ml Pneumatic El Nominal Operating Pressure El Exempt [
Other []
Pressure -
psi Test Temp.
'F
- 9. Remarks: None.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this replacement conforms to the rules of ASME Code,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. G A Program Certificate of Authorization No.
N/A Expiration Date N/A Signed Ownvj pr,5r-Pate te4 07 20o8 V]
Owner ot" Owner's Degignee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois
, and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period l
to A-7/
.., and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
&d i
Commissions
/ 2.
A J.5"--
Inspect9K Wfure National Board. State. Provirice. and Endo rv.ment4
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI
- 1. Owner:
Exelon Generation Company, LLC 4300 Winfield Road Warrenville, It. 60555 2.Plant:
Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242
- 3. Work Performed by:
Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 Date:
04/15/2008 Sheet:
I of 1 Unit:
2 Program No.07-065 WO 1012229-01 Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp:
Authorization No.:
Expiration Date:
None None N/A
- 4. Identification of System: High Pressure Coolant Injection, Class 1
- 5. (a) Applicable Construction Code: USAS B31.1 1967 / ASME Section 1 1965 Edition, ASME Section 11966 Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
1995 Edition, 1996 Addenda, N/A Code Case
- 6. Identification of Cor onents Repaired or Replaced, and Replacement Components:
Name of Name of Mfrs. Ser.
Nat'l Other Year
- Repaired, ASME Component Mfr.
No.
Bd.
Identification Built Replaced, or Code No.
Replacement Stamped (Yes or No)
Snubber Lisega 30700115 / 008 N/A 2-2305-77 N/A Replacement No
- 7. Description of Work: Replaced mechanical snubber with hydraulic and replaced rear bracket in accordance with WO.
- 8. Tests Conducted:
Hydrostatic []
Pneumatic [
Nominal Operating Pressure El Exempt [
Other LI Pressure __
psi Test Temp._
'F
- 9. Remarks: None.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this replacement conforms to the rules of ASME Code,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. Q A Program Certificate of Authorization No.
N/A Expiration Date N/A Signed 0
k
-A, Date AV 20 0 8" Owner ortOwne'sDesignee, Title
,-..g CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois
, and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period 11/3!7 to
, and state that to the best of my knowledge and belief, the owner has performed examinations and taken correctie measures described in this Owner's Report in accordance the requirements of the ASME Code, Section XT.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
aL ii
- -,~zq
'-IA ~~
AI)AL i
Z.Alfilf 3ft~3I IDate 1nsate 20 ignat'reV National Board, State. Province, and Endorsements 20 of' I
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI
- 1. Owner:
Exelon Generation Company, LLC 4300 Winfield Road Warrenville, I1. 60555 2.Plant:
Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242
- 3. Work Performed by:
Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 Date:
04/07/2008 Sheet:
I of I Unit:
2 Program No.07-066 WO 1012224-01 Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp:
Authorization No.:
Expiration Date:
None None N/A
- 4. Identification of System:
High Pressure Coolant Injection, Class 1
- 5. (a) Applicable Construction Code:
USAS B31.1 1967
- Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
1995 Edition, 1996 Addenda, N/A Code Case
- 6. Identification of Com ponents Repaired or Replaced, and Replacement Components:
Name of Name of Mfrs. Ser.
Nat'l Other Year
- Repaired, ASME Component Mfr.
No.
Bd.
Identification Built Replaced, or Code No.
Replacement Stamped (Yes or No)
Snubber Lisega 30700115 / 010 N/A 2-2305-76 N/A Replacement No
- 8. Tests Conducted:
Hydrostatic [3 Pneumatic El Nominal Operating Pressure E]
Exempt 0 Other El Pressure __ psi Test Temp.
F
- 9. Remarks: None.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this replacement conforms to the rules of ASME Code,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No.
N/A Expiration Date N/A Signed Llý
, ;-,FR-0.,
es,0,ny,---
Date il o3 20 o0 V
O)wner br Ownef's JesigneelTitlet I I
CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois
, and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period
)/I,//A.]
to _4__/__,__ - and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
_Commissions
//_L
ýJ 6`3 (pel5 Signature -
/
National Board, State. Province, and Endorsements
,7 1A F-i t a,
)1
=..-..-
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI
- 1. Owner:
Exelon Generation Company, LLC 4300 Winfield Road Warrenville, I1. 60555 2.Plant:
Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242
- 3. Work Performed by:
Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 Date:
04/07/2008 Sheet:
I of I Unit:
2 Program No.07-067 WO 1012231-01 Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp:
Authorization No.:
Expiration Date:
None None N/A
- 4. Identification of System:
High Pressure Coolant Injection, Class 2
- 5. (a) Applicable Construction Code:
USAS B31.1 1967
- Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
1995 Edition, 1996 Addenda, N/A Code Case
- 6. Identification of Components Repaired or Replaced, and Replacement Components:
Name of Name of Mfrs. Ser.
Nat'l Other Year
- Repaired, ASME Component Mfr.
No.
Bd.
Identification Built Replaced, or Code No.
Replacement Stamped (Yes or No)
Snubber Lisega 01615123 / 083 N/A 2-2305-78 N/A Replacement No
- 8. Tests Conducted:
Hydrostatic El Pneumatic El Nominal Operating Pressure C3 Exempt Z Other C]
Pressure psi Test Temp.
'F
- 9. Remarks: None.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this replacement conforms to the rules of ASME Code,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No.
N/A Expiration Date N/A Signed o
M*1 5pv,--
Date Aw; I o7 20 06 V
Owher or Owner's Desiglnee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois
, and emnloyed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period
.L,/,, *!aLto and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code, Section X1.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
(Jag zU 4 ~ i~~
Commissions Z
Inspectort~ighidre A 1 1
/-5
'I National Board. State, Province, and Endorsements 20
- oA 20 c
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI
- 1. Owner:
Exelon Generation Company, LLC 4300 Winfield Road Warrenville, I1. 60555 2.Plant:
Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242
- 3. Work Performed by:
Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 Date:
04/18/2008 Sheet:
I of I Unit:
2 Program No.07-069, 08-024,08-055 WO 1002228-01, 13, 16 Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp:
Authorization No.:
Expiration Date:
None None N/A
- 4. Identification of System:
Main Steam, Class 2
- 5. (a) Applicable Construction Code:
USAS B31.1 1967
- Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
1995 Edition, 1996 Addenda, N-416-3 Code Case
- 6. Identification of Components Repaired or Replaced, and Replacement Components:
Name of Name of Mfrs. Ser.
Nat'l Other Year
- Repaired, ASME Component Mfr.
No.
Bd.
Identification Built Replaced, or Code No.
Replacement Stamped (Yes or No)
Gate Valve Crane Company D6776 N/A 2-0220-1 N/A Replacement No
- 8. Tests Conducted:
Hydrostatic D Pneumatic El Nominal Operating Pressure [
Exempt [
Other []
Pressure __
psi Test Temp.
OF
- 9. Remarks: None.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this replacement conforms to the rules of ASME Code,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. Q A Program Certificate of Authorization No.
N/A Expiration Date N/A Signed 2O 2ý
/e Date 20 6 Owner or Owner's Designee, Title I'
CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois
, and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period 11&* 1/" -7 to 4/&L.. "o
, and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
Commissions National Board, State, Province, and Endorsements lnspfio1VS0nature-V 90 tS*
Date.
202~ 68
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI
- 1. Owner:
Exelon Generation Company, LLC 4300 Winfield Road Warrenville, I1. 60555 2.Plant:
Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242
- 3. Work Performed by:
Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 Date:
04/04/2008 Sheet:
I of I Unit:
2 Program No.07-070 WO 1012223-01 Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp:
Authorization No.:
Expiration Date:
None None N/A
- 4. Identification of System:
Reactor Core Isolation Cooling, Class I
- 5. (a) Applicable Construction Code:
USAS B31.1 1967
- Edition, N/A Addenda, N/A CodeCase (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
1995 Edition, 1996 Addenda, N/A Code Case
- 6. Identification of Components Repaired or Replaced, and Replacement Components:
Name of Name of Mfrs. Ser.
Nat'i Other Year
- Repaired, ASME Component Mfr.
No.
Bd.
Identification Built Replaced, or Code No.
Replacement Stamped (Yes or No)
Hydraulic Snubber Lisega 01615123 / 086 N/A 2-1307-42 N/A Replacement No
- 8. Tests Conducted:
Hydrostatic 0 Pneumatic D Nominal Operating Pressure E]
Exempt 0 Other El Pressure psi Test Temp.
'F
- 9. Remarks: None.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this replacement conforms to the rules of ASME Code,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No.
N/A Expiration Date N/A Signed orAý-
0 Tvile-Date Apre 0-7 20 6b V]
Uwner or Owrfer't Design6e, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois
, and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period L/Z2-2/k L" to I.Z.L/0 r
, and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
(Lif
-Commissions L
Iaspectoj/Siin¶a6re
/10 ý. ~I it
/
National Board. State, Province, and Endorsements 20 o09
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI
- 1. Owner:
Exelon Generation Company, LLC 4300 Winfield Road Warrenville, I1. 60555 2.Plant:
Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242
- 3. Work Performed by:
Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 Date:
04/15/2008 Sheet:
I of I Unit:
2 Program No.07-075, 07-086 WO 954420-02, 03 Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp:
Authorization No.:
Expiration Date:
None None N/A
- 4. Identification of System:
Standby Liquid Control, Class 2
- 5. (a) Applicable Construction Code:
USAS B31.1 1967 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
1995 Edition, 1996 Addenda,. N/A Code Case
- 6. Identification of Co ponents Repaired or Replaced, and Replacement Components:
Name of Name of Mfrs. Ser.
Nat'l Other Year
- Repaired, ASME Component Mfr.
No.
Bd.
Identification Built Replaced, or Code No.
Replacement Stamped (Yes or No)
Standby Liquid Conax Buffalo N/A N/A 2-1106-B N/A Replacement No Control Squib Corp.
Valve
- 7. Description of Work: Replaced Trigger Assembly and Inlet Fitting in accordance with WO.
- 8. Tests Conducted:
Hydrostatic 0 Pneumatic El Nominal Operating Pressure Z Exempt El Other E]
Pressure psi Test Temp.
'F
- 9. Remarks: None.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this replacement conforms to the rules of ASME Code,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No.
N/A Expiration Date N/A Signed P /S1 Date 200/
I Owner or Ownft's Designee,"¶itle CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois
. and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period I-
/ý/-
to 4
L
, and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
Ail JIIIý Commissions 1L
,'5 1-Inspectors.-gn-I National Board, State, Province, and Endorsements Date 2o o
Date 20 0 ?t
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI
- 1. Owner:
Exelon Generation Company, LLC 4300 Winfield Road Warrenville, I!. 60555 2.Plant:
Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242
- 3. Work Performed by:
Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 Date:
04/07/2008 Sheet:
I of I Unit:
2 Program No.07-076 WO 949147-01
'Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp:
Authorization No.:
Expiration Date:
None None N/A
- 4. Identification of System:
Main Steam, Class 1
- 5. (a) Applicable Construction Code: USAS B31.1 1967 and ASME Section III 1965/1968 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
1995 Edition, 1996 Addenda, N/A Code Case
- 6. Identification of Components Repaired or Replaced, and Replacement Components:
Name of Name of Mfrs. Ser.
Nat'l Other Year
- Repaired, ASME Component Mfr.
No.
Bd.
Identification Built Replaced, or Code No.
Replacement Stamped (Yes or No)
Safety Relief Valve Dresser Industries BK 6295 N/A 2-0203-4C N/A Replacement No
- 7. Description of Work: Replaced valve and hydranuts in accordance with WO.
- 8. Tests Conducted:
Hydrostatic EL Pneumatic [l Nominal Operating Pressure Z Exempt [I Other LI Pressure __ psi Test Temp.
'F
- 9. Remarks: None.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this replacement conforms to the rules of ASME Code,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No.
N/A Expiration Date N/A Signed I*e -Z".S td*j-teDate
'//
20 -0" Owner or Owner's Degignee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois
, and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period
!/
to.4/y/l/o1
, and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code, Section Xl.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
(1,44____
_ _Commissions i1-t.)
lns*rctoOK Mgnatture
- National Board, State, Province. and Endorsements Date
",.c 1ý1 20 03 Dae fIlA 0
O
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI
- 1. Owner:
Exelon Generation Company, LLC 4300 Winfield Road Warrenville, I. 60555 2.Plant:
Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242
- 3. Work Performed by:
Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 Date:
04/07/2008 Sheet:
I of I Unit:
2 Program No.07-077 WO 949148-01 Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp:
Authorization No.:
Expiration Date:
None None N/A
- 4. Identification of System:
Main Steam, Class 1
- 5. (a) Applicable Construction Code: USAS B31.1 1967 and ASME Section III 1965/1968 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
1995 Edition, 1996 Addenda, N/A Code Case
- 6. Identification of Components Repaired or Replaced, and Replacement Components:
Name of Name of Mfrs. Ser.
Nat'l Other Year
- Repaired, ASME Component Mfr.
No.
Bd.
Identification Built Replaced, or Code No.
Replacement Stamped (Yes or No)
Safety Relief Valve Dresser Industries BK 6531 N/A 2-0203-4D N/A Replacement No
- 7. Description of Work: Replaced valve and hvdranuts in accordance with WO.
- 8. Tests Conducted:
Hydrostatic U Pneumatic El Nominal Operating Pressure Z Exempt F]
Other U Pressure psi Test Temp._
'F
- 9. Remarks: None.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this replacement conforms to the rules of ASME Code,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No.
N/A Expiration Date N/A Signed A
XS" Date
,h2,.,//
/*¢ 200 g Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois
, and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period 1.2.7A/o, 7 to A7hL /ae°
, and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code, Section Xl.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
ii 27-n Commissions d~
J5 inspE~t, 1X-igmature
/
National Board. State. Pnivince. and Endorsements Date 4 A, e
/9
÷ Date lAA~~
/
~20 CQ'
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI
- 1. Owner:
Exelon Generation Company, LLC 4300 Winfield Road Warrenville, II. 60555 2.Plant:
Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242
- 3. Work Performed by:
Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 Date:
03/28/08 Sheet:
I of I Unit:
2 Program No.07-078 WO 949149-01 Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp:
Authorization No.:
Expiration Date:
None None N/A
- 4. Identification of System:
Main Steam, Class I
- 5. (a) Applicable Construction Code: USAS B31.1 1967 and Section III 1965, 1968 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
1995 Edition, 1996 Addenda, N/A Code Case
- 6. Identification of Components Repaired or Replaced, and Replacement Components:
Name of Name of Mfrs. Ser.
Nat'l Other Year
- Repaired, ASME Component Mfr.
No.
Bd.
Identification Built Replaced, or Code No.
Replacement Stamped (Yes or No)
Main Steam Safety Dresser Industries BK 7167 N/A 2-0203-4G N/A Replacement No Relief Valve
- 7. Description of Work: Replaced valve and hydranuts in accordance with WO.
- 8. Tests Conducted:
Hydrostatic []
Pneumatic
]
Nominal Operating Pressure Z Exempt 51 Other U Pressure _
psi Test Temp.
'F
- 9. Remarks: None.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this replacement conforms to the rules of ASME Code,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear 10CFR50 App B. 0 A Program Certificate of Authorization No.
N/A Expiration Date N/A Signed 4
4 ý4!,,
-,o 5*,pv,,-
Date I4 C,,
'21 20 o0 V
Owner 6r Owner's'De'ignee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois and employed by HSB CT. of Hartford. Connecticut have inspected the components described in this Owner's Report during the period t(j-1 7
to +4/4,L L
, and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
_ _j_
1
,__4___
_Commissions I L
,.L. s-i Inspectors SignareU1 j)
National lBoard. State. Province, and Endorsements On I. 6 On 1
20 0 k
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI
- 1. Owner:
Exelon Generation Company, LLC 4300 Winfield Road Warrenville, II. 60555 2.Plant:
Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242
- 3. Work Performed by:
Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 Date:
04/08/2008 Sheet:
1 of I Unit:
2 Program No.07-079 WO 949 150-01 Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp:
Authorization No.:
Expiration Date:
None None N/A
- 4. Identification of System:
Main Steam, Class 1
- 5. (a) Applicable Construction Code: USAS B31.1 1967 and ASME Section III 1965/1968 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
1995 Edition, 1996 Addenda, N/A Code Case
- 6. Identification of Components Repaired or Replaced, and Replacement Components:
Name of Name of Mfrs. Ser.
Nat'l Other Year
- Repaired, ASME Component Mfr.
No.
Bd.
Identification Built Replaced, or Code No.
Replacement Stamped (Yes or No)
Safety Relief Valve Dresser Industries BL 2471 N/A 2-0203-4H N/A Replacement No
- 7. Description of Work: Replaced valve and hydranuts in accordance with WO.
- 8. Tests Conducted:
Hydrostatic El Pneumatic El Nominal Operating Pressure [
Exempt Other El Pressure __
psi Test Temp.
'F
- 9. Remarks:
None.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this replacement conforms to the rules of ASME Code,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No.
N/A Expiration Date N/A Signed
/
-*Own*iZee
'TI t
-Zk6 Date
/
V 20 6?,?
Owner or Owner'sDesigtiee, Title/
CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois
, and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period
,,.Z,
to -,
/
L'-
, and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
d'o
'J Commissions L
Ins to nat re National Board, State, Province, and Endorsements 20 08 T
4--
Date I r(n~
20 c'8
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI
- 1. Owner:
Exelon Generation Company, LLC 4300 Winfield Road Warrenville, I1. 60555 2.Plant:
Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242
- 3. Work Performed by:,
Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 Date:
04/04/2008 Sheet:
I of I Unit:
2 Program No.07-080 WO 949146-01 Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp:
None Authorization No.:
None Expiration Date:
N/A
- 4. Identification of System:
Main Steam, Class I
- 5. (a) Applicable Construction Code:
USAS B31.1 1967
- Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
1995 Edition, 1996 Addenda, N/A Code Case
- 6. Identification of Corponents Repaired or Replaced, and Replacement Components:
Name of Name of Mfrs. Ser.
Nat'l Other Year
- Repaired, ASME Component Mfr.
No.
Bd.
Identification Built Replaced, or Code No.
Replacement Stamped (Yes or No)
Electromatic Relief Dresser Industries BK 7060 N/A 2-0203-3D N/A Replacement No Valve I
r
- 7. Description of Work: Replaced Electromatic Relief Valve and Hydranuts in accordance with WO.
- 8. Tests Conducted:
Hydrostatic nl Pneumatic nl Nominal Operating Pressure [
Exempt El Other nl Pressure psi Test Temp.
'F
- 9. Remarks: None.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this replacement conforms to the rules of ASME Code,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No.
N/A Expiration Date N/A Signed C
o
- .wesý,
ý",,-
Date Apf II 07 20 ob V
q (wner of: Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION
[, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois
, and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period 5/7/t0 t to.'/i/o i
, and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
-Commissions SL Inspectors Sifalt#keJ V J
National Board. State. Province. and Endorsements Date 9
20 o*
fl~te
(%
A 920 02
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI
- 1. Owner:
Exelon Generation Company, LLC 4300 Winfield Road Warrenville, I1. 60555 2.Plant:
Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242
- 3. Work Performed by:
Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 Date:
04/15/2008 Sheet:
I of 1 Unit:
2 Program No.07-081 WO 1041555-01 Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp:
Authorization No.:
Expiration Date:
None None N/A
- 4. Identification of System:
Main Steam, Class 1 5, (a) Applicable Construction Code: USAS B31.1 1967 and Section III 1965, 1968 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
1995 Edition, 1996 Addenda, N/A Code Case
- 6. Identification of Co ponents Repaired or Replaced, and Replacement Components:
Name of Name of Mfrs. Ser.
Nat'l Other Year
- Repaired, ASME Component Mfr.
No.
Bd.
Identification Built Replaced, or Code No.
Replacement Stamped (Yes or No)
Main Steam Safety Dresser Industries BK 6318 N/A 2-0203-4A N/A Replacement No Relief Valve
- 7. Description of Work: Replaced valve and bolting in accordance with WO.
- 8. Tests Conducted:
Hydrostatic El Pneumatic El Nominal Operating Pressure Z Exempt El Other El Pressure -
psi Test Temp.
F
- 9. Remarks: None.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this replacement conforms to the rules of ASME Code,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No.
N/A Expiration Date N/A Signed 2Qne i,
/sj/
L.
Date A1
/ /
20 QT.
Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois
, and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period Z!j,-,o7 to
_l/rog
, and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this'inspection.
Commissions
/ /
2)-9J
-- nsp.-tt ignature National Board, State, Pnrvince, and Endorsements Date
[7 zg/t*
/A*
20 og Date 17 6A.-Z dA 20 0*
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI
- 1. Owner:
Exelon Generation Company, LLC 4300 Winfield Road Warrenville, I1. 60555 2.Plant:
Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242
- 3. Work Performed by:
Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 Date:
04/04/2008 Sheet:
I of I Unit:
2 Program No.07-091 WO 837563-01 Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp:
Authorization No.:
Expiration Date:
None None N/A
- 4. Identification of System:
Main Steam, Class 1
- 5. (a) Applicable Construction Code:
USAS B31.1 1967
- Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
1995 Edition, 1996 Addenda, N/A Code Case
- 6. Identification of Components Repaired or Replaced, and Replacement Components:
Name of Name of Mfrs. Ser.
Nat'l Other Year
- Repaired, ASME Component Mfr.
No.
Bd.
Identification Built Replaced, or Code No.
Replacement Stamped (Yes or No)
Electromatic Relief Dresser Industries BK 7063 N/A 2-0203-3C N/A Replacement No
- 7. Description of Work: Replaced Electromatic Relief Valve and bolting in accordance with WO.
- 8. Tests Conducted:
Hydrostatic E]
Pneumatic "
Nominal Operating Pressure [
Exempt U Other F1 Pressure psi Test Temp.
OF
- 9. Remarks: None.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this replacement conforms to the rules of ASME Code,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No.
N/A Expiration Date N/A Signed a
Ivps,-_Date AprI IC7 206 VOv/ner of Owner's Designee, Tlitle CERTIFICATE OF INSERVICE INSPECTION
[ the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois
, and employed by HSB C7. of Hartford. Connecticut have inspected the components described in this Owner's Report during the period
.A7/by.
to -4h/il*
, and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
I
/
41 UCommissions i L..
Asp:4rs Signature National Board. State, Pruvince, and Endorserrents Date da, L6 20 08
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI
- 1. Owner:
Exelon Generation Company, LLC 4300 Winfield Road Warrenville, I1. 60555 2.Plant:
Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242
- 3. Work Performed by:
Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 Date:
04/08/2008 Sheet:
1 of I Unit:
2 Program No.07-097 WO 953365-01 Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp:
Authorization No.:
Expiration Date:
None None N/A
- 4. Identification of System:
Feedwater, Class 1
- 5. (a) Applicable Construction Code:
USAS B31.1 1967
- Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
1995 Edition, 1996 Addenda, N/A Code Case
- 6. Identification of Components Repaired or Replaced, and Replacement Components:
Name of Name of Mfrs. Ser.
Natl Other Year
- Repaired, ASMIE Component Mfr.
No.
Bd.
Identification Built Replaced, or Code No.
Replacement Stamped (Yes or No)
Check Valve Exelon N/A N/A 2-0220-58B N/A Replacement No
- 7. Description of Work: Replaced trim set in accordance with WO.
- 8. Tests Conducted:
Hydrostatic El Pneumatic E]
Nominal Operating Pressure E]
Exempt 0 Other U Pressure -
psi Test Temp.
'F
- 9. Remarks: Local Leak Rate Test performed.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this replacement conforms to the rules of ASME Code,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No.
N/A Expiration Date N/A Signed K
/S51 *',,d,,w Date
,,.','/
/$'
20.49f Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois
, and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period
-1 A,: -2 to A'
,and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
$4*/-_Z, z
_L<,z-----
Commissions
/ 1-
/
InspeortSi~ ature y"
National Board, State, Province, and Endorsements Date 6.,IA-j
---/
20 O*
÷ flate20 64
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI
- 1. Owner:
Exelon Generation Company, LLC 4300 Winfield Road Warrenville, II. 60555 2.Plant:
Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242
- 3. Work Performed by:
Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 Date:
05/08/2008 Sheet:
I of 3 Unit:
2 Program No. See Attachment A, WO 912799 Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp:
Authorization No.:
Expiration Date:
None None N/A
- 4. Identification of System: Control Rod Drive, Class I
- 5. (a) Applicable Construction Code: Component: ASME Section III 1965 Edition, Winter 1965 Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
1995 Edition, 1996 Addenda, N/A Code Case
- 6. Identification of Components Repaired or Replaced, and Replacement Components:
Name of Name of Mfrs. Ser.
Nat'l Other Year
- Repaired, ASME Component Mfr.
No.
Bd.
Identification Built Replaced, or Code No.
Replacement Stamped (Yes or See Attachment A No)
- 7. Description of Work: Replaced Control Rod Drives and bolting in accordance with the W.O.
- 8. Tests Conducted:
Hydrostatic El Pneumatic E]
Nominal Operating Pressure [
Exempt E Other [
Pressure psi Test Temp.
OF
- 9. Remarks:
None CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this replacement conforms to the rules of ASME Code,Section XI repair or replacement Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No.
N/A Expiration Date N/A Signed X;
i, /s
-e-Date Ael.
." 20 69 Owner or Owner's Designee, Titlt" CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois
, and employed by HSB CT. of Connecticut have inspected the components described in this Owner's Report during the period 1
to Z,,
and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
Commissions
/ L
,2-National Board. State, Prvince, and Endor..ements Date l) a,1,Ct
)3 20 CA'
- 6 FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT (Supplement)
As Required by the Provisions of ASME Code Section XI
- i. Owner:
Exelon Generation Company, LLC 4300 Winfield Road Warrenville, I1. 60555 2.Plant:
Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 Date:
05/08/2008 Sheet:
2 of 3 Unit:
2 Program No. See Attachment A, WO 912799 Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp:
None
- 3. Work Performed by:
Quad Cities Generating Station Authorization No.:
None 22710 206th Ave. North, Cordova, IL 61242 Expiration Date:
N/A
- 4. Identification of System: Control Rod Drive, Class I
- 5. (a) Applicable Construction Code: Component: ASME Section III 1965 Edition, Winter 1965 Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
1995 Edition, 1996 Addenda, N/A Code Case Attachment A Name of Name of Mfrs. Ser.
Nat'l Other Year
- Repaired, ASME Program Component Mfr.
No.
Bd.
Identification Built Replaced, or Code No.
No.
Replacement Stamped (Yes or No)
Control Rod Drive GE Nuclear S/N: 8355 N/A 2-0300-14-07 N/A Replacement Yes08-004 Energy Control Rod Drive GE Nuclear S/N: 403 N/A 2-0300-02-35 N/A Replacement Yes08-005 Energy Control Rod Drive GE Nuclear S/N: D1496 N/A 2-0300-14-35 N/A Replacement Yes08-006 Energy Control Rod Drive GE Nuclear S/N: 350 N/A 2-0300-22-27 N/A Replacement Yes08-007 Energy Control Rod Drive GE Nuclear S/N: 6572 N/A 2-0300-22-55 N/A Replacement Yes08-008 Energy Control Rod Drive GE Nuclear S/N: A4782 N/A 2-0300-26-19 N/A Replacement Yes08-009 Energy Control Rod Drive GE Nuclear S/N: 2135 N/A 2-0300-26-39 N/A Replacement Yes08-010 Energy Control Rod Drive GE Nuclear S/N: 2880 N/A 2-0300-26-47 N/A Replacement Yes08-011 Energy Control Rod Drive GE Nuclear S/N: 7737 N/A 2-0300-26-55 N/A Replacement Yes08-012 Energy Control Rod Drive GE Nuclear S/N: A8927 N/A 2-0300-30-59 N/A Replacement Yes08-013 Energy Control Rod Drive GE Nuclear S/N: A85 10 N/A 2-0300-34-27 N/A Replacement Yes08-014 Energy Control Rod Drive GE Nuclear S/N: 6559 N/A 2-0300-34-51 N/A Replacement Yes08-015 Energy Control Rod Drive GE Nuclear S/N: A4232 N/A 2-0300-42-19 N/A Replacement Yes08-016 Energy Control Rod Drive GE Nuclear S/N: 344 N/A 2-0300-42-23 N/A Replacement Yes08-017 Energy Control Rod Drive GE Nuclear S/N: 1390 N/A 2-0300-42-27 N/A Replacement Yes08-018 Energy
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT (Supplement)
As Required by the Provisions of ASME Code Section XI
- 1. Owner:
Exelon Generation Company, LLC 4300 Winfield Road Warrenville, I1. 60555 2.Plant:
Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 Date:
05/08/2008 Sheet:
3 of 3 Unit:
2 Program No. See Attachment A, WO 912799 Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp:
None
- 3. Work Performed by:
Quad Cities Generating Station Authorization No.:
None 22710 206th Ave. North, Cordova, IL 61242 Expiration Date:
N/A
- 4. Identification of System: Control Rod Drive, Class i
- 5. (a) Applicable Construction Code: Component: ASME Section III 1965 Edition, Winter 1965 Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
1995 Edition, 1996 Addenda, N/A Code Case Name of Name of Mfrs. Ser.
Nat'l Other Year
- Repaired, ASME Program Component Mfr.
No.
Bd.
Identification Built Replaced, or Code No.
No.
Replacement Stamped (Yes or No)
Control Rod Drive GE Nuclear S/N: 617 N/A 2-0300-42-51 N/A Replacement Yes08-019 Energy I
Control Rod Drive GE Nuclear S/N: 573 N/A 2-0300-46-31 N/A Replacement Yes08-020 Energy Control Rod Drive GE Nuclear S/N: A3255 N/A 2-0300-50-11 N/A Replacement Yes08-021 Energy Control Rod Drive GE Nuclear S/N: 6540 N/A 2-0300-50-47 N/A Replacement Yes08-022 Energy Control Rod Drive GE Nuclear S/N: 6470 N/A 2-0300-54-31 N/A Replacement Yes08-023 Energy I
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI
- 1. Owner:
Exelon Generation Company, LLC 4300 Winfield Road Warrenville, II. 60555 2.Plant:
Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242
- 3. Work Performed by:
Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 Date:
04/23/2008 Sheet:
I of I Unit:
0 Program No.08-028, 08-029 PO 420577 Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp:
Authorization No.:
Expiration Date:
None None N/A
- 4. Identification of System:
Main Steam, Class 1
- 5. (a) Applicable Construction Code:
USAS B31.1 1967
- Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
1995 Edition, 1996 Addenda, 'N/A Code Case
- 6. Identification of Com ponents Repaired or Re laced, and Replacement Components:
Name of Name of Mfrs. Ser.
Nat'l Other Year
- Repaired, ASME Component Mfr.
No.
Bd.
Identification Built Replaced, or Code No.
Replacement Stamped (Yes or No)
Electromatic Relief Dresser Industries BK 7063 N/A Spare N/A Repair /
No Valve I
Replacement
- 7. Description of Work: Re-weld the turnbuckle boss and machinc the flange face in accordance with WO.
- 8. Tests Conducted:
Hydrostatic El Pneumatic 0 Nominal Operating Pressure Fl Exempt [
Other El Pressure -
psi Test Temp.
'F
- 9. Remarks: None.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this repair / replacement conforms to the rules of ASME Code,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No.
N/A Expiration Date N/A Signed Date
/,1 a
I 20 Of8 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois
, and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period I.710JA to 4/24/of
, and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
__C Commissions iiL
,IS1 inspect~rs Kgdture-National Board. State. Pnwince. and Endorsements Date
- 7-41 20 tg*
L fl~tP 20
/41
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI
- 1. Owner:
Exelon Generation Company, LLC 4300 Winfield Road Warrenville, II. 60555 2.Plant:
Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242
- 3. Work Performed by:
Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 Date:
04/23/2008 Sheet:
I of I Unit:
0 Program No.08-033 PO 420577 Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp:
Authorization No.:
Expiration Date:
None None N/A
- 4. Identification of System:
Main Steam, Class 1
- 5. (a) Applicable Construction Code:
USAS B31.1 1967
- Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
1995 Edition, 1996 Addenda, N/A Code Case
- 7. Description of Work: Re-weld the turnbuckle boss in accordance with WO.
- 8. Tests Conducted:
Hydrostatic El Pneumatic []
Other F1
'Pressure __ psi Nominal Operating Pressure LI Exempt [
Test Temp.
OF
- 9. Remarks: None.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this replacement conforms to the rules of ASME Code,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No.
N/A Expiration Date N/A Signed A"2
. /' /
Date Atir4/ iS 20 0 Owner or Owner's Oesignee, Titr e CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois
, and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period e
tA o
LL.. to
, and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
A/
Commissions iL
.. l 5 P
I~f~pecrors Signature fU(
National Board, State, Province, and Endorsements 20 zDI Dae_
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI
- 1. Owner:
Exelon Generation Company, LLC 4300 Winfield Road Warrenville, I1. 60555 2.Plant:
Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242
- 3. Work Performed by:
Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 Date:
04/04/2008 Sheet:
I of I Unit:
2 Program No.08-036 WO 1012200-01' Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp:
Authorization No.:
Expiration Date:
None None N/A
- 4. Identification of System:
Residual Heat Removal, Class 2
- 5. (a) Applicable ConstructionCode:
USAS B31.1 1967
- Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
1995 Edition, 1996 Addenda, N/A Code Case
- 6. Identification of Components Repaired or Replaced, and Replacement Components:
Name of Name of Mfrs. Ser.
Nat'l Other Year
- Repaired, ASME Component Mfr.
No.
Bd.
Identification Built Replaced, or Code No.
Replacement Stamped (Yes or
_ _No)
Snubber Pacific Scientific 816 N/A 2-1025-103 N/A Replacement No
- 8. Tests Conducted:
Hydrostatic El Pneumatic El Nominal Operating Pressure El Exempt 0 Other F1 Pressure -
psi Test Temp._
'F
- 9. Remarks: None.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this replacement conforms to the rules of ASME Code,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 ApV B. 0 A Program Certificate of Authorization No.
N/A Expiration Date N/A Signed csw" ne r
Psig¢-
, Date AP 07 20 F&,
V (Pwnet or Owner'tElesignee,,'itle I CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois
, and employed by HSB CT. of Hartford. Connecticut have inspected the components described in this Owner's Report during the period d*2 -7L..
to
-4/,1//og
, and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code, Section Xl.
By signing this Certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
4na Commissions
,L
- l-Inspectors Sjna~At National Board, State, Province, and Endorsements Date 1i 20 0_
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI
- 1. Owner:
Exelon Generation Company, LLC 4300 Winfield Road Warrenville, I. 60555 2.Plant:
Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242
- 3. Work Performed by:
Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 Date:
04/16/2008 Sheet:
I of 1 Unit:
2 Program No.08-040 WO 1040755-01 Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp:
None Authorization No.:
None Expiration Date:
N/A
- 4. Identification of System:
Residual Heat Removal, Class 1
- 5. (a) Applicable Construction Code:
USAS B3 1.1 1967
- Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
1995 Edition, 1996 Addenda, N/A Code Case
- 6. Identification of Components Repaired or Replaced, and Re placement Components:
Name of Name of Mfrs. Ser.
Nat'l Other Year
- Repaired, ASME Component Mfr.
No.
Bd.
Identification Built Replaced, or Code No.
Replacement Stamped (Yes or No)
Pipe Exelon N/A N/A 2-1025-20"-A N/A Replacement No
- 8. Tests Conducted:
Hydrostatic El Pneumatic El Nominal Operating Pressure El Exempt 0 Other [
Pressure psi Test Temp.
OF
- 9. Remarks: None.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this replacement conforms to the rules of ASME Code,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No.
N/A Expiration Date N/A Signed L--,/51
-"fn v
Date 4,"'I
/*
20 t.
Owner or Ownei~s Designee, Tite CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois
, and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period 4 h "!Ig-- -
to
/6 1 a
, and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code, Section Xl.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
a,:,
-Commissions t
,-.5-?
inspectitfs 4fatd mtm'¢
/
National Board, State, Pnrvince, and Edaorements Date Om, 0
-It 20 02
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI
- 1. Owner:
Exelon Generation Company, LLC 4300 Winfield Road Warrenville, I1. 60555 2.Plant:
Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242
- 3. Work Performed by:
Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 Date:
04/07/2008 Sheet:
1 of I Unit:
2 Program No.08-042 WO 1112317-01 Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp:
Authorization No.:
Expiration Date:
None None N/A
- 4. Identification of System:
Residual Heat Removal, Class I
- 5. (a) Applicable Construction Code:
USAS B31.1 1967
- Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
1995 Edition, 1996 Addenda, N/A Code Case
- 6. Identification of Co ponents Repaired or Replaced, and Rplacement Components:
Name of Name of Mfrs. Ser.
Nat'l Other Year
- Repaired, ASME Component Mfr.
No.
Bd.
Identification Built Replaced, or Code No.
Replacement Stamped (Yes or
_No)
Snubber Lisega 03615806 / 08 N/A 2-1025-83 N/A Replacement No
- 8. Tests Conducted:
Hydrostatic Dl Pneumatic El Nominal Operating Pressure El Exempt [
Other E1 Pressure psi Test Temp.
OF
- 9. Remarks: None.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this replacement conforms to the rules of ASME Code,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear 10CFR50 ApV B. Q A Program Certificate of Authorization No.
N/A Expiration Date N/A Signed (W
l,
. J,,1A 14 f
,,¢*rf Date A, 1?1 o:7
.200o
".O~verior Owner'S Ddsignee, Tille CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois
, and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period 32/3/O&
to
-_/11,10
, and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
KL/
~
Commissions L )
'5-lnspe4tX9Vgnature Natkmal Board, State, Province, and Endorsements Date 20 0)?
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI
- 1. Owner:
Exelon Generation Company, LLC 4300 Winfield Road Warrenville, I1. 60555 2.Plant:
Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242
- 3. Work Performed by:
Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 Date:
04/07/2008 Sheet:
I of I Unit:
2 Program No.08-043 WO 1112323-01 Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp:
Authorization No.:
Expiration Date:
None None N/A
- 4. Identification of System:
Residual Heat Removal, Class I
- 5. (a) Applicable Construction Code:
USAS B31.1 1967
- Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
1995 Edition, 1996 Addenda, N/A Code Case
- 6. Identification of Components Repaired or Replaced, and Re placement Components:
Name of Name of Mfrs. Ser.
Nat'l Other Year
- Repaired, ASME Component Mfr.
No.
Bd.
Identification Built Replaced, or Code No.
Replacement Stamped (Yes or No)
Snubber Lisega 03615806 / 09 N/A 2-1025-85 N/A Replacement No
- 8. Tests Conducted:
Hydrostatic E]
Pneumatic El Nominal Operating Pressure El Exempt 0 Other E]
Pressure psi Test Temp.
'F
- 9. Remarks: None.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this replacement conforms to the rules of ASME Code,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear I OCFR50 App2 B. 0 A Program Certificate of Authorization No.
N/A Expiration Date N/A Signed AA&\\L, 0
m y',
"q¢r-Date
,r,'
07 20 a,9 V,
O~lner or Ownerts DUesignee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois
, and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period 3
13 Ia, to
__/_____
, and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
_ _ _/__
Commissions
,/ _
.2"5-9 Inspect(s SAgrlure National Board, State. Province, and Endorsements Date 20 o$"
LDa~te 20 0fr
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI
- 1. Owner:
Exelon Generation Company, LLC 4300 Winfield Road Warrenville, I1. 60555 2.Plant:
Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242
- 3. Work Performed by:
Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 Date:
04/04/2008 Sheet:
I of I Unit:
2 Program No.08-044 WO 1112324-01 Repair Organization P.O. No., Job No., etc, Type Code Symbol Stamp:
Authorization No.:
Expiration Date:
None None N/A
- 4. Identification of System:
Residual Heat Removal, Class 1
- 5. (a) Applicable Construction Code:
USAS B31.1 1967
- Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
1995 Edition, 1996 Addenda, N/A Code Case
- 6. Identification of Components Repaired or Replaced, and Replacement Components:
Name of Name of Mfrs. Ser.
Nat'l Other Year
- Repaired, ASME Component Mfr.
No.
Bd.
Identification Built Replaced, or Code No.
Replacement Stamped (Yes or No)
Hydraulic Snubber Lisega 03615806 / 06 N/A 2-1025-86 N/A Replacement No
- 8. Tests Conducted:
Hydrostatic El
- Pneumatic El Nominal Operating Pressure E Exempt 0 Other [
Pressure psi Test Temp..__
F
- 9. Remarks: None.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this replacement conforms to the rules of ASME Code,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 Ap1 B. 0 A Program Certificate of Authorization No.
N/A Expiration Date N/A Signed CNAA L L
.,-1 O
,*As5 Frvae 5Ep,"5r-Date krdfr1 O7 20 o&
V O0"er or Owner' s1D ignee, Ti~tle CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois
, and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period
___,,3_ a__ to
_____A_
, and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
_____________Commissions IL
_;l)51 Inspectorsn4g
("
I National Board. State, Province. and Endorsements Date V
20 1.2bV
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI
- 1. Owner:
Exelon Generation Company, LLC 4300 Winfield Road Warrenville, I1. 60555 2.Plant:
Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242
- 3. Work Performed by:
Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 Date:
04/07/2008 Sheet:
I of 1 Unit:
2 Program No.08-045 WO 112311-01 Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp:
Authorization No.:
Expiration Date:
None None N/A
- 4. Identification of System:
Residual Heat Removal, Class 1
- 5. (a) Applicable Construction Code:
USAS B31.1 1967
- Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
1995 Edition, 1996 Addenda, N/A Code Case
- 6. Identification of Components Repaired or Replaced, and Replacement Components:
Name of Name of Mfrs.. Ser.
Nat'l Other Year
- Repaired, ASME Component Mfr.
No.
Bd.
Identification Built Replaced, or Code No.
Replacement Stamped (Yes or No)
12752 N/A 2-1012-B7 N/A Replacement No
- 8. Tests Conducted:
Hydrostatic El Pneumatic El Nominal Operating Pressure El Exempt 2 Other E]
Pressure psi Test Temp.
'F
- 9. Remarks: None.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this replacement conforms to the rules of ASME Code,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No.
N/A Expiration Date N/A Signed I
619,4AF&
1vpY-r-Date A rI'l 07 2006 V
qwner& r Owner's'Dotignee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois
, and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period Zo 8 to 411a. 89, and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
Commissions IL Insp 1V" Natkinal Board, State, Province, and Endorsements 20 O
Date 0-
/ V 20 0 k-
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI
- 1. Owner:
Exelon Generation Company, LLC 4300 Winfield Road Warrenville, Ii. 60555 2.Plant:
Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242
- 3. Work Performed by:
Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 Date:
04/07/2008 Sheet:
I of I Unit:
2 Program No.08-046 WO 1112322-01 Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp:
None Authorization No.:
None Expiration Date:
N/A
- 4. Identification of System:
Residual Heat Removal, Class I
- 5. (a) Applicable Construction Code:
USAS B31.1 1967
- Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
1995 Edition, 1996 Addenda, N/A Code Case
- 6. Identification of Corponents Repaired or Replaced, and Replacement Components:
Name of Name of Mfrs. Ser.
Nat'l Other Year
- Repaired, ASME Component Mfr.
No.
Bd.
Identification Built Replaced, or Code No.
Replacement Stamped (Yes or No)
Snubber Lisega 03615806 / 07 N/A 2-1025-84 N/A Replacement No
- 8. Tests Conducted:
Hydrostatic []
Pneumatic El Nominal Operating Pressure El Exempt 0 Other El Pressure psi Test Temp.
'F
- 9. Remarks: None.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this replacement conforms to the rules of ASME Code,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. Q A Program Certificate of Authorization No.
N/A Expiration Date N/A Signed A
A L t!
ve Date A.pt-rI 07 2006 V
Oner or'Owner's Designee, Tile' CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois
, and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period 4
3J 6,81---- to 122k L..., and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code, Section Xl.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
insp~
"ue
" *+v"*/V-.--
Commissions I L
.2 IS1 National Board. State, Province. and Endorsements Date 04
- n of flot ~
~
~
2 64,.!
4
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI
- 1. Owner:
Exelon Generation Company, LLC 4300 Winfield Road Warrenville, 11. 60555 2.Plant:
Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242
- 3. Work Performed by:
Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 Date:
04/07/2008 Sheet:
I of I Unit:
2 Program No.08-047 WO 1012216-01 Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp:
Authorization No.:
Expiration Date:
None None N/A
- 4. Identification of System:
Reactor Water Clean-up, Class 1
- 5. (a) Applicable Construction Code:
USAS B31.1 1967
- Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
1995 Edition, 1996 Addenda, N/A Code Case
- 6. Identification of Components Repaired or Replaced, and Replacement Components:
Name of Name of Mfrs. Ser.
Nat'l Other Year
- Repaired, ASME Component Mfr.
No.
Bd.
Identification Built Replaced, or Code No.
Replacement Stamped (Yes or Snubber Lisega 06315806 / 05 N/A 2-1202-88 N/A Replacement No
- 8. Tests Conducted:
Hydrostatic El Pneumatic El Nominal Operating Pressure E]
Exempt 0 Other El Pressure -
psi Test Temp._ 'F
- 9. Remarks: None.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this replacement conforms to the rules of ASME Code,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear 10CFR50 App B. 0 A Program Certificate of Authorization No.
N/A Expiration Date N/A Signed cW-A=Ar P-..
Pvv-.-
Date Ap-11 07 200b V,
Otvner or Owner's 13esignee,-Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois
, and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period
- 3!/3 9
to ALy /o, It
, and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
Commissions
- 1.
Inspecto 5'
- r.
National Board, State. Province, and Endorsements Date
/1 20 O..
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI
- 1. Owner:
Exelon Generation Company, LLC 4300 Winfield Road Warrenville, I1. 60555 2,Plant:
Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242
- 3. Work Performed by:
Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 Date:
04/07/2008 Sheet:
1 of I Unit:
2 Program No.08-048 WO 1012213-01 Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp:
Authorization No.:
Expiration Date:
None None N/A
- 4. Identification of System:
Reactor Water Clean-up, Class 1
- 5. (a) Applicable Construction Code:
USAS B31.1 1967
- Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
1995 Edition, 1996 Addenda, N/A Code Case
- 6. Identification of Co ponents Repaired or Replaced, and Replacement Components:
Name of Name of Mfrs. Ser.
Nat'l Other Year
- Repaired, ASME Component Mfr.
No.
Bd.
Identification Built Replaced, or Code No.
Replacement Stamped (Yes or No)
Snubber Lisega 036151806/ 10 N/A 2-1202-87 N/A Replacement No
- 8. Tests Conducted:
Hydrostatic El Pneumatic 0l Nominal Operating Pressure El Exempt [
Other Fl Pressure psi Test Temp.
F
- 9. Remarks: None.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this replacement conforms to the rules of ASME Code,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear 10CFR50 App B. 0 A Program Certificate of Authorization No.
N/A Expiration Date N/A Signed
!5
,p_,__'-
-Date At______1 0-7 20__
Sn (wnrer or Ownef's Uesignea, Title' CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois
, and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period
- 4/,./g
-f to L.... and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
J A,
-Commissions
),L 9-nspecnlS tture.....
National Board, State, Province, and Endorsements Date
/0 20 09" Date LZ9,,.L
,0 20
~
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI
- 1. Owner:
Exelon Generation Company, LLC 4300 Winfield Road Warrenville, I1. 60555 2.Plant:
Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242
- 3. Work Performed by:
Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 Date:
04/14/2008 Sheet:
I of I Unit:
2 Program No.08-050 WO 880548-01 Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp:
None Authorization No.:
None Expiration Date:
N/A
- 4. Identification of System:
High Pressure Coolant Injection, Class 2
- 5. (a) Applicable Construction Code:
USAS B31.1 1967
- Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
1995 Edition, 1996 Addenda, N/A Code Case
- 6. Identification of Co ponents Repaired or Replaced, and Replacement Components:
Name of Name of Mfrs. Ser.
Nat'l Other Year
- Repaired, ASME Component Mfr.
No.
Bd.
Identification Built Replaced, or Code No.
Replacement Stamped (Yes or No)
HPCI Gland Seal Exelon N/A N/A 2-2305 N/A Replacement No Condenser
- 7. Description of Work: Replaced bolting in accordance with WO.
- 8. Tests Conducted:
Hydrostatic E1 Pneumatic Fl Nominal Operating Pressure [
Exempt [
Other E Pressure psi Test Temp.
'F
- 9. Remarks: None.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this replacement conforms to the rules of ASME Code,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No.
N/A Expiration Date N/A Signed Date 4/,-,
/V "
20 eg Owner or Owner {'Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois
, and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period
.1VXPk to,4/Zi/.,
and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures describ/ed in this Owner's Report in accordance the requirements of the ASME Code,Section XI.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
Commissions 1L
,2/.,-
Jnspect,ýSifna e
National Board, State. Prtvince. and Endorsements rlýt.
/I, /
,-e 20 ok
4RI 0
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI
- 1. Owner:
Exelon Generation Company, LLC 4300 Winfield Road Warrenville, I1. 60555 2.Plant:
Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242
- 3. Work Performed by:
Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 Date:
04/08/2007 Sheet:
I of I Unit:
2 Program No.08-052, 08-053 WO 949152-07,04 Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp:
Authorization No.:
Expiration Date:
None None N/A
- 4. Identification of System:
Residual Heat Removal, Class 2
- 5. (a) Applicable Construction Code:
USAS B31.1 1967
- Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
1995 Edition, 1996 Addenda, N-416-3 Code Case
- 6. Identification of Components Repaired or Replaced, and Replacement Components:
Name of Name of Mfrs. Ser.
Nat'l Other Year
- Repaired, ASME Component Mfr.
No.
Bd.
Identification Built Replaced, or Code No.
Replacement Stamped (Yes or No)
Relief Valve Consolidated Power TP76531 N/A 2-1001-125D N/A Replacement Yes Supply I
I
- 7. Description of Work: Replaced relief valve.discharge piping and flange bolting in accordance with WO.
- 8. Tests Conducted:
Hydrostatic F1 Pneumatic E1 Nominal Operating Pressure [
Exempt Fl Other E Pressure psi Test Temp.
F
- 9. Remarks: None.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this replacement conforms to the rules of ASME Code,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. Q A Program Certificate of Authorization No.
N/A Expiration Date N/A Signed Date tNO 20 t Signed 04ner or Owner's Degigdee, T it pv*
2 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period
?J&/o k" to -.//vh/'
, and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
_________________Co Commissions I L
,*2 5
- n,&k*aors'SignatureJ (/National Board. State, Province, 'ad Endorsements Dnte n 0"I I (ý 20 0
Date 20 c~'