July 1978 U.S. NUCLEAR REGULATORY COMMISSION

REGULATORY GUIDE

OFFICE OF STANDARDS DEVELOPMENT

REGULATORY GUIDE 1.56 MAINTENANCE OF WATER PURITY IN BOILING

WATER REACTORS

A. INTRODUCTION

General Design Criteria 14, "Reactor Coolant Pressure Boundary," and 31, "Fracture Prevention of Reactor Coolant Pressure Boundary," of Appen dix A, "General Design Criteria for Nuclear Power Plants," to 10 CFR Part 50, "Domestic Licensing of Production and Utilization Facilities," require assur ance that the reactor coolant pressure boundary will have minimal probability of gross rupture or rapidly propagating failure.

General Design Criterion 15, "Reactor Coolant System Design," requires that the reactor coolant system and associated auxiliary, control, and protec tion 'systems be designed with sufficient margin to ensure that the design conditions of the reactor cool ant pressure boundary are not exceeded during any condition of normal operation, including antici operational occurrences. Failure of the reactor

0

ant pressure boundary may be postulated whe the mechanisms of general corrosion and str rrr cracking induced by impurities in the rmctor c lan are present.

Furthermore, General Design Criterion-,

"In strumentation and Control requires that instrumen tation be provided to variables and systems that can affect the reac pressure boundary over their antici ra fo normal operation, for anticipated rat I urrences, and for acci dent condilpn s ap priate to ensure adequate safety.*

Y

This g describes a method acceptable to the NRC staff f

.mplementing the criteria with regard to minimizing the probability of corrosion-induced failure of the reactor coolant pressure boundary in

  • The substantial number of changes in this revision has made it impractical to indicate the changes with lines in the margin.

boiling water reactors (BWRs) by maintaining ac ceptable purity levels in the reactor coolant. It further describes instrumentation acceptablejthe NRC staff for determining the condition of reactor coolant and coolant purification syste i

S.

B. DI

Water quality ro s during construction when extensive e e n essary to ensure that components p

e clean. Concern with proper ter n

m start even before the plant operate* ..

nti~e through all operations until finlshu aintenance of high water quality is nt ng all operations since water is often mra fn one part of the plant to another dur

-ta s and this water can easily find its way to he ell and from there to the reactor.

"Tn a typical BWR direct or single cycle reactor sys tem (see Fig. 1 in the appendix), water is boiled by means of a nuclear fission heat source. The steam and water mixture produced in the core area passes through steam separators where much of the water is removed. Wet steam passes from the separators to the steam dryers to produce relatively dry steam (less than 1/10 of a percent moisture). The steam at ap proximately 1000 psi and 550'F (288°C) enters the main steam lines and passes through the turbine to the main condenser. Condensed steam is collected in the hotwell located below the cooling tubes of the condenser. Leaks in the condenser tubes can result in circulating water entering the hotwell and introducing impurities. When the circulating water in the conden sers is seawater, the consequences of tube leaks may be quite significant; therefore, special precautions are required in seawater-cooled plants.

De-aeration in the condenser reduces the oxygen content of the water. The condensate then passes USNRC REGULATORY GUIDES

Comments should be sent to the Secretary of the Commission, US. Nuclear Regu Regulatory Guides are issued to describe and make available to the public methods latory Commission, Washington, D.C.

20555. Attention Docketing and Service accepltable to the NRC staff of implementing specific parts of the Commission's Branch.

regulations, to delineate techniques used by the staff in evaluating specific problems The guides are issued in the lol lowing ten broad divisions on postulated accidents, or to provide guidance to applicants. Regulatory Guides are not substitutes for regulations, and compliance with them is not required.

1. Power Reactors

6. Products Methods and solutions different from those set out in the guides will be accept-

2. Research and Test Reactors

7. Transportation able if they provide a basis for the findings requisite to the issuance or continuance

3. Fuels and Mlterials Facilities

8. Occupational Health of a permit or license by the Commission.

4. Environmental and Siting

9. Antitrust Review

5. Materials and Plant Protection t0. General Comments and suggestions for improvements in these guides are encouraged at all times, and guides will be revised, as appropriate, to accommodate comments and Requests for single copies of issued guides (wl ch may be reproducedl or for place to reflect new information or experience.

However, comments on this guideif ment on an automatic distribution list for single copies of future guides in specific received within about two months after its issuance, will be particularly useful in divisions should be made in writing to the US. Nuclear Regulatory Commission.

evaluating the need for an early revision.

Washington, D.C.

20555. Attention:

Director. Division of Document Control.

through full-flow demineralizers in order to obtain the purest possible feedwater. The condensate de mineralizers remove insoluble corrosion products by filtration and remove dissolved ionic materials, i.e.,

metals and salts, by ion exchange. They also afford limited prbtection from large condenser tube leaks until corrective action is initiated. The feedwater passes through the feedwater heaters and enters the reactor at about 385°F (196°C). Since there is no

"blowdown," the reactor water concentrates all the soluble and insoluble materials that enter via the feedwater. In BWRs, the reactor water cleanup sys tem performs the blowdown function by removing soluble and insoluble impurities from the reactor wa ter. Thus, extremely pure feedwater is provided by the equipment as necessary.

In BWRs, the various heat exchangers of auxiliary systems are barriers between high-purity reactor water and cooling water that may be contaminated with dissolved or suspended solids.

Main condenser leakage is a potential source of such contaminants. Such leakage should be minimized by proper condenser design and by provid ing for reliable detection' of leakage. The rate of con denser leakage may be estimated from measurements of the electrical conductivity of the water in the con denser hotwell or in the line between the hotwell and the demineralizer. A meter with sufficient range to measure all water conductivity levels at least up to the limiting conditions of the technical specifications that require immediate shutdown of the reactor should be provided.

The condensate demineralizer system is provided between the condenser and the reactor vessel to re duce impurities from condenser leakage and other sources to an acceptable level. A typical condensate demineralizer consists of several parallel ion ex change units, the resins in which serving both to remove ionic impurities and to filter out suspended solids.

Depending on the flow rate, type of resin, cleanli ness of resin of BWR full-flow demineralizer sys tems, and type of ions in the coolant, total capacity may not be available for ionic impurity removal in the condensate treatment system before decontamina tion factors become unacceptably low during con denser leakage. Demineralizer capacity reduction should be considered in the design so that there is adequate capacity margin available to permit orderly shutdown of the reactor in case of a serious con denser leak.

There are no instruments that will directly measure the capacity of a demineralizer unit. The capacity may be determined indirectly, however, from the ini tial capacity of the unit and the calculated flows of ions through the unit. Subtraction of the total ion flow from the initial capacity gives the remaining capacity.

Operation of a demineralizer unit after its ion exchange capacity has been depleted results in the di rect passthrough of ions into the reactor vessel. De pending on the nature of these ions, stress-corrosion cracking or other forms of corrosion might be accel erated, crud buildup on fuel and on other components might be promoted, and plant radiation levels might be increased.

The conductivity of the inlet and outlet water of the demineralizer-should be measured to monitor de mineralizer performance. The monitoring instrument, which should be set to trigger alarms in the control room, should be capable of quickly detecting de mineralizer breakthrough and should have sufficient range to measure all conductivity levels up to and in cluding the limiting conditions of the plant technical specifications that require immediate shutdown of the reactor.

Even with highly efficient condensate demineraliz ers, some contaminants, at very low concentrations, pass into the reactor vessel. Chloride ions and high or low pH conditions, which may promote stress corrosion cracking of austenitic stainless steel com ponents and structures, are of particular concern.

To control contaminants within limiting condi tions, the conductivity of the coolant at the inlet.and outlet of the reactor water cleanup system should be continuously monitored. The chloride content and pH

of the reactor water should be determined periodi cally. The reactor should not be operated for ex tended periods of time with the reactor water cleanup system out of service.

Limits on chloride concentration and pH in the reactor vessel water of BWRs that have been found acceptable to the NRC staff are presented in the ap pendix to this guide. Also presented in the appendix are representative limits for the electrical conductiv ity of the water at several other locations in the BWR

water cycle.

C. REGULATORY POSITION

Condensate demineralizers in boiling water reac tors should be designed and operated so as to permit an orderly shutdown of the reactor in case of serious leakage in the condenser or in other heat exchangers without contaminating the reactor coolant pressure boundary or core structural components with poten tially harmful constituents of the condenser cooling water. Sufficient instrumentation should be provided so that (1) the electrical conductivity of the conden sate is known, (2) the available capacity of the con d~nsate demineralizers can be determined at all times, and (3) the conductivity of the reactor coolant water at the inlet and outlet of each demineralizer is

1.56-2

known. Additional protection to the pressure vessel and core structural components should be provided in the form of a functioning reactor water cleanup sys tem and instrumentation to measure reactor water conductivity. An acceptable approach is as follows:

1. The licensee should establish appropriate limits for the electrical conductivity of purified condensate to the reactor vessel (the electrical conductivity of the BWR feedwater cycle and that of the reactor water cleanup cycle). Separate limits may be required for such operating conditions as startup, hot standby, low power, high power, and at temperatures _<212'F

(100°C).

Chemical analyses for dissolved and suspended impurities should be performed as called for in the plant technical specifications. A conductivity meter should be provided at each condenser hotwell or in the line between the hotwell and the condensate de mineralizer with sufficient range to measure at least all levels of conductivity up to and including the lim iting conditions of the technical specifications that require immediate shutdown of the reactor. The rec ording conductivity meters recommended in regula tory position 4.a may be used for this purpose.

2. The licensee should establish the sequential resin regeneration frequency or resin replacement frequency required to maintain adequate capacity margin in the condensate treatment system for postu lated condenser cooling water inleakage. The capac ity required and corresponding resin regeneration or replacement frequency will depend on several parameters, including condenser cooling water com position, chloride concentration, flow rate in each demineralizer unit, type and quantity of resin, cation/anion resin ratio, postulated condenser leak age, and time for orderly reactor shutdown.

3. The initial total capacity of the new anion and cation demineralizer resins should be measured.

Anion exchange capacity may be determined by a procedure recommended by the resin manufacturer.

The total exchange capacity of the cation resin may be measured by a procedure recommended by the resin manufacturer or by paragraphs 41 through 49 of ASTM D2181-71, "Standard Methods of Test of Physical and Chemical Properties of Ion-Exchange Resins. -* For resins that are to be regenerated, these determinations should be repeated at least semiannu ally. The resins should be discarded and replaced when their capacity following regeneration falls below 60 percent of the initial value. More frequent determinations should be made at plants using seawa ter or other water containing large amounts of dis

,solved or suspended matter as coolant in their heat exchangers. For resins that are not regenerated but

  • Copies may be obtained from the American Society for Test ing and Materials, 1916 Race Street, Philadelphia, Pennsylvania

19103.

are instead replaced periodically with material of the same type, measurements of initial capacity should be made on a sample of new material at least once a year (when the time between replacements is less than 1 year) or at each replacement (when the time between replacements exceeds'l year). When the type of anion or cation resin is changed, a measure ment of total capacity of the replacement resin should be made prior to use in the demineralizer.

4. The licensee should verify that the minimum re sidual demineralizer capacity in the most depleted demineralizer unit established in accordance with the recommendations of regulatory position 2 is main tained. The following is an example of an acceptable method for determining the condition of the de mineralizer units so that the ion exchange resin can be replaced or regenerated before an unacceptable level of depletion is reached.

a. Recording conductivity meters should be in stalled at the inlet and outlet of both the condensate treatment system and reactor water cleanup system.

The range of these instruments should be sufficient to measure all levels of potential water conductivity specified in the plant technical specifications. For the condensate treatment system, the conductivity meter readings should be calibrated so that estimates of condenser leakage can be made based on cooling water conductivity, condensate conductivity, and flow rate. The chemical composition of the cooling water and its relation to specific conductance should be established and periodically confirmed so that es timates of residual demineralizer capacity can be made.

b. A recording flowmeter should be used to measure the rate of flow through each demineralizer.

c. The quantity of the principal ion(s) likely to cause demineralizer breakthrough should be calcu lated by:

(1) Converting the conductivity readings of the water entering the demineralizer to weight fraction (e.g., ppm or ppb) of the principal, ion(s) and

(2) Integrating over time the product of con centration of this ion(s) and demineralizer flow.

The input quantity of ion(s) to the demineralizers should be determined at a frequency adequate to en sure sufficient residual ion exchange capacity in the event of a major condenser leakage to prevent ex ceeding reactor coolant limits.

d. Each demineralizer unit should be replaced or regenerated when the remaining capacity (calculated by subtracting the total utilization determined from conductivity and flow measurements in accordance with regulatory position 4.c from the initial capacity

1.56-3

determined in accordance with regulatory position 3)

approaches the minimum residual demineralizer capacity determined in accordance with regulatory position 2. The accuracy of the above calculation should be checked by measurements made on resin samples taken when demineralizer units are removed from service for regeneration or resin cleaning.

Measurements on samples from each unit should be made at each of the first two such removals from service and at every fifth such removal from service thereafter. If appropriate, the actual measurements may be used to adjust the calculated value of residual demineralizer capacity. Such adjustment and its jus tification should be reported to the NRC in the annual operating report.

5. The conductivity meter(s) located at the inlet and outlet of the demineralizer(s) of the condensate treatment system and the reactor water cleanup sys tem should be set to trigger alarms in the control room when, as a minimum, either of the following conductivity levels is reached (values of which should be determined by the licensee):

a. The level that indicates marginal performance of the demineralizer systems.

b. The level that indicates noticeable break through of one or more demineralizers.

6. The chloride content in the reactor vessel water should be maintained as low as practical. The ionic equilibria of the reactor vessel water should be con- trolled to ensure a neutral pH. The licensee should establish limits for conductivity, pH, and chlorides in the reactor vessel water and should specify proce dures to be used for their determination. Acceptable reactor water chemistry limits are given in Table 1 of the appendix to this guide. If the limiting values of the conductivity, pH, or chloride content are ex ceeded, appropriate corrective actions as defined in the plant technical specifications should be taken.

D. IMPLEMENTATION

The purpose of this section is to provide informa tion to applicants and licensees regarding the NRC

staff's plans for using this regulatory guide.

With the exception of the recommendation of regu latory position 4.a on additional conductivity meters as applied to operating plants, this guide reflects cur rent NRC staff practice. Therefore, except in those cases in which the applicant or licensee proposes an acceptable alternative method for complying with specified portions of the Commission's regulations, the method described herein is being and will con tinue to be used in the evaluation of submittals in connection with operating license or construction permit applications until this guide is revised as a re sult of suggestions from the public or additional staff review. Regulatory position 4.a will be used in the evaluation of the performance of operating plant licensees on a case-by-case basis.

1.56-4

APPENDIX

The data presented in this appendix illustrate the water quality levels acceptable to the NRC staff for the BWR reactor vessel and condensate system.

Table 1 provides conductivity, pH, and chloride lim its for BWR reactor water during various plant operating conditions, including maximum acceptable levels for short durations and special conditions. The relationships among conductivity, pH, and chloride concentration in water at 77°F (25°C) are presented in Figure 2 of this appendix. (Reference "Chloride Con- trol in BWR Coolants," General Electric Report NEDO-10899, 73NED59, Class 1, June 1973.) This relationship is acceptable in establishing appropriate conductivity/pH limits and alarm setpoints.

Table 2 provides conductivity limits for the con densate treatment system to ensure maintenance of reactor water quality limitations. The limits indicated establish action points for the corrective actions re quired to maintain reactor water quality limits.

1.56-5

TABLE 1 ACCEPTABLE REACTOR WATER CHEMISTRY LIMITS

PARAMETER

Specific Conductance at 777F (25°C)

1. Power Operation Steaming rates greater than

1% of rated steamflow

2. Startup/Hot Standby and Power Operation Steaming rates less than

1% of rated steamflow

3. Cold Shutdown Reactor is not pressurized [i.e.,

LIMIT

I /mho/cma

2/zmho/cmc MAXIMUM

LIMIT

10 Atmho/cmb at or below 212"k (100IC)]

10 jimho/cm Chloride

1. Power Operation Steaming rates greater than

1% of rated steamflow

0.2 ppma

0.5 ppmb

2. Startup/Hot Standby and Power Operation Steaming rates less than

1% of rated steamflow

0.1 ppm

3. Cold Shutdown Reactor is not pressurized [i.e.,

at or below 212°F (100°C)]

0.5 ppm pH at 777F (25C)

1. Steaming rates greater than 1%

of rated steamflow

2. Reactor is not pressurized [i.e.,

at or below 212°F (100°C)]

pH not less than

5.6 nor greater than 8.6d pH not less than

5.3 nor greater than 8.6 a Time above I lzmho/cm at 77°F (25C) and 0.2 ppm chloride not to exceed 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> for any single incident, but the total time for all incidents should not exceed 2 weeks per year. When the time limits are exceeded, an orderly shutdown should be initiated within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />.

b When the maximum conductivity or chloride concentration limits are exceeded, an orderly shutdown should be initiated immediately, and the reactor should be brought to the cold standby condition as rapidly as cooldown rate permits.

C Time above 2.Amho/cm at 77°F (25C) and 0.1 ppm chloride not to exceed 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> for any single occurrence. When the time limits are exceeded, the reactor should be brought to the hot shutdown condition until the limits are restored.

d The reactor should be shut down if pH is <5.6 or >8.6 for a period of 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br />.

TABLE 2 ACCEPTABLE CONDUCTIVITY LIMIT OF CONDENSATE SYSTEM WATER

SPECIFIC CONDUCTANCE AT 77-F (25-C)

(jwmho/cm)

Location Condensate Inlet to Demineralizer Treated Condensate Combined Demineralizer Outlet Individual Demineralizer Outlet Limita Maximum Limit'

0.5

0.1

0.2

10

0.2

0.5 a Indicating condenser leakage or marginal demineralizer performance requiring corrective action to be taken as defined in plant techni cal specifications.

b Indicating orderly reactor shutdown and/or corrective actions to be taken immediately.

1.56-6

Figure 1 BWR WATER CYCLE

1.56-7

100

ILu o

a

0.50

0

I-"

0 .30

o

1.0

0

0.20

2

1.0

0.50

0.1 z

0.,

0.20

,.

0.05.

.

z

0.03-0.10

w Jw

0.0

0.

0..0

0.001

0.014 I

I1

4

5.0

5.6

6

7

8

8.6

9 pH

Figure 2 CONDUCTIVITY, pH, AND CHLORIDE

CONCENTRATION OF AQUEOUS SOLUTIONS

AT 77 0 F (250 C)

1.56-8