PLA-7047, Th Rio Steam Dryer Visual Inspection Report

From kanterella
Jump to navigation Jump to search

Th Rio Steam Dryer Visual Inspection Report
ML13207A101
Person / Time
Site: Susquehanna Talen Energy icon.png
Issue date: 07/25/2013
From: Franke J
Susquehanna
To:
Office of Nuclear Reactor Regulation, Document Control Desk
References
PLA-7047, TAC MD3309, TAC MD3310
Download: ML13207A101 (28)


Text

JUL 2 5 2013 Jon A. Franke Site Vice President U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555-0001 PPL Susquehanna, LLC 769 Salem Boulevard Berwick, PA 18603 Tel. 570.542.2904 Fax 570.542.1504 jfranke@pp1web.com SUSQUEHANNA STEAM ELECTRIC STATION UNIT 2 16TH RIO STEAM DRYER VISUAL INSPECTION REPORT PLA-7047 Docket No. 50-388

Reference:

Letter, R. V. Guzman (NRC) to B. T. McKinney (PPL), Susquehanna Steam Electric Station, Units I and 2-Issuance of Amendment Regarding the 13-Percent Extended Power Uprate (TAC Nos. MD3309 and MD33/0)," dated January 30, 2008.

This submittal provides the results of the steam dryer visual inspections conducted during the Susquehanna SES (SSES) Unit 2 16 1h Refueling and Inspection Outage (RIO). The results are contained in Enclosure 1 and meet the intent of SSES Unit 2 License Condition 2.C.(20)(f) from the above reference.

Additionally, SSES Unit 2 License Condition 2.C.(20)(e) requires that visual inspections be conducted of all accessible, susceptible locations of the steam dryer during the first two scheduled refueling outages after reaching full CPPU (Constant Pressure Power Uprate) conditions. This report is for the first of the two outages after reaching full CPPU conditions. The last inspection in accordance with this License Condition will be performed in the SSES Unit 2 refueling and inspection outage in 2015.

There are no new regulatory commitments contained in this submittal.

If you have questions, please contact D. L. Filchner at (610) 774-7819.

. A. Franke -Unit 2 License Condition 2.C.(20)(f) Steam Dryer Inspection Results Copy: NRC Region I Mr. P. W. Finney, NRC Sr. Resident Inspector Mr. J. A. Whited, NRC Project Manager Mr. L. J. Winker, PA DEP/BRP TM

ENCLOSURE 1 TO PLA-7047 "Unit 2 License Condition 2.C.(20)(f)

Steam Dryer Inspection Results" to PLA-7047 Page 1 of 26 License Condition 2.C. (20) (f)

Susquehanna Unit 2 Steam Dryer Inspection Results

Purpose:

To report the results of the Unit 2 16RIO Steam Dryer visual inspections to satisfy Unit 2 License Condition 2.C. (20) (f).

Executive Summary: The Unit 2 Steam Dryer was inspected in accordance with the requirements of BWRVIP-139 and the manufacturer, General Electric, recommendations.

Three hundred sixty four (364) visual examinations were performed on welds and components. Newly discovered non-conforming conditions were identified as follows:

Minor IGSCC on DRYER WELD DC-C-2. Reference CR 1693833. Indication has been dispositioned as use-as-is.

Swirl patterns, discoloration and surface roughness areas discovered on Dryer Hood A and Dryer Hood F. Reference CR 1697522 and 1699122. Indications have been dispositioned as use-as-is.

Minor IGSCC in the heat affected zone of components Dryer Lug LL-C 220 Deg Lower Bracket and Dryer Lug LL-D 320 Deg Middle bracket. Reference CR 1692786. Indications have been dispositioned as use-as-is.

Minor IGSCC indications on the Dryer ID component Skirt Panel 0 Deg Left Side.

Reference CR 1697229. Indications have been dispositioned as use-as-is.

Dryer Skirt gouges and anomalies found at different azimuths. Reference CR 1697237, 1697451 and 1700339. Indications have been dispositioned as use-as-Is.

Fatigue cracks in components Dryer 140-Deg Lifting Lug to Eye Fillet Welds and Dryer 320-Deg Lifting Lug to Eye Fillet Welds. Reference CR 1693833 and 1692786. Indications have been dispositioned as use-as-is.

Previously identified indications that showed growth or other changes during Unit 2 16RIO were the following:

Dryer Lug LL-B 140 Deg Lower Bracket component indication removed by flapping in 2011 was re-discovered in 2013. Reference CR 1692786. Indication has been dispositioned as use-as-is.

Dryer Skirt Weld 135 Deg multiple IGSCC indications identified in 2011 showed additional growth. Reference CR 1692786. Indications were dispositioned as use-as-Is.

All locations listed above are scheduled for re-inspection during the Unit 2 17RIO in 2015 to determine if changes have occurred.

to PLA-7047 Page 2 of26 License Condition 2.C. (20) (f)

Susquehanna Unit 2 Steam Dryer Inspection Results The following areas were previously identified in 2011 (PLA-6751) as containing defects. There has been no change in condition identified in 2013 inspection.

Dryer Skirt 4 Degree Seismic Ring Drill Hole Repair ID and OD.

Dryer Skirt non-service induced gouges and anomalies.

No other non-conformities were identified during the inspection process.

The entire inspections scope will be repeated during the Unit 2 17RIO in 2015 to meet the requirements of License Condition 2.C. (20) (e). A sampling program will be utilized for dryer visual inspection in subsequent RIOs.

Inspection Methods Used:

The VT -1 visual examination is utilized to visually determine the condition of a part, component or surface and to reveal such conditions as cracks, wear, corrosion, erosion and/or physical damage to such parts, especially welded joints.

The VT -3 visual examination is utilized to determine structural integrity, the measurement of clearances, detection of physical displacement, determination of the structural adequacy of supporting elements, the soundness of connections between load carrying structural members, and tightness of bolting.

Inspection Results Identification:

NRI-No recordable Indication. The weld or component was in compliance with the inspection acceptance criteria, no cracks or deformation during inspection was discovered. No further actions required.

RI-Recordable Indication. The weld or component contained a defect such as a crack or deformation that resulted in further evaluation and disposition in the Corrective Action Program. A component with a Recordable Indication discovered in 2011 with no change in condition detected in 2013 is reported in 2013 as an RI, however, a Condition Report is not required.

Note: EWR 1716365 provides evaluation of previous operating cycle(s) to determine if plant conditions were representative of the upcoming cycle and that indications with no growth during Unit 2 16RIO are still acceptable.

Component Name DRYER LUG LL-A 40 DEG DRYER LUG LL-B 140 DEG DRYER LUG LL-C 220 DEG DRYER LUG LL-D 320 DEG DRYER SEISMIC RING LUG A

DRYER SEISMIC RING LUG A

DRYER SEISMIC RING LUG A

DRYER SEISMIC RING LUG B

DRYER SEISMIC RING LUG B

DRYER SEISMIC RING LUG B

DRYER SEISMIC RING LUG c

DRYER SEISMIC RING LUG c to PLA-7047 Page 3 of26 License Condition 2.C. (20) (f)

Susquehanna Unit 2 Steam Dryer Inspection Results Method Inspection Inspection Condition Description Disposition Date Result Report (If Rl)

VT-3 19-Apr-13 NRI VT-3 19-Apr-13 NRI VT-3 16-Apr-13 NRI VT-3 17-Apr-13 NRI VT-1 16-Apr-13 NRI VT-1 16-Apr-13 NRI VT-3 16-Apr-13 Rl NA WEAR PATTERN NOCR ON UNDERSIDE GENERATE-OF SEISMIC NO CHANGE BLOCK IN CONDITION FROM 2011 VT-1 25-Apr-13 NRI VT-1 25-Apr-13 NRI VT-3 25-Apr-13 Rl NA CONTACT MARKS NOCR FROM DRYER GENERATE-SUPPORT NO CHANGE BRACKET AT 94 IN DEGREES CONDITION FROM 2011 VT-1 18-Apr-13 NRI VT-1 18-Apr-13 NRI

Component Name DRYER SEISMIC RING LUG c

DRYER SEISMIC RING LUG D

DRYER SEISMIC RING LUG D

DRYER SEISMIC RING LUG D

DRYER WELD DC-A-I DRYER WELD DC-A-2 DRYER WELD DC-A-3 DRYER WELD DC-B-1 DRYER WELD DC-B-2 DRYER WELD DC-B-3 DRYER WELD DC-C-1 DRYER WELD DC-C-2 to PLA-7047 Page 4 of26 License Condition 2.C. (20) (f)

Susquehanna Unit 2 Steam Dryer Inspection Results Method Inspection Inspection Condition Description Disposition Date Result Report (IfRI)

VT-3 18-Apr-13 RI NA WEAR PATTERN NOCR ON UNDERSIDE GENERATE-OF SEISMIC NO CHANGE BLOCK IN CONDITION FROM 2011 VT-1 24-Apr-13 RI 1699205 ADDITIONAL USE-AS-IS WEAR PATTERN ON UNDERSIDE OF SEISMIC BLOCK AND SUPPORT LUG VT-1 24-Apr-13 NRI VT-3 24-Apr-13 RI 1699205 ADDITIONAL USE-AS-IS WEAR PATTERN ON UNDERSIDE OF SEISMIC BLOCK AND SUPPORT LUG VT-1 16-Apr-13 NRI VT-1 17-Apr-13 NRI VT-1 17-Apr-13 NRI VT-1 17-Apr-13 NRI VT-1 17-Apr-13 NRI VT-1 17-Apr-13 NRI VT-1 18-Apr-13 NRI VT-1 18-Apr-13 RI 1693833 AXIAL USE-AS-IS INDICATION LEFT OF HEAT AFFECTED ZONE APPROXIMATELY 0.55 INCHES

Component Name DRYER WELD DC-C-3 DRYER WELD DC-D-1 DRYER WELD DC-D-2 DRYER WELD DC-D-3 DRYER WELD HE-A-l DRYER WELD HE-A-2 DRYER WELD HE-B-1 DRYER WELD HE-B-2 DRYER WELD HE-C-1 DRYER WELD HE-C-2 DRYER WELD HE-D-1 DRYER WELD HE-D-2 DRYER WELD HE-E-l DRYER WELD HE-E-2 DRYER WELD HE-F-1 DRYER WELD HE-F-2 DRYER WELD TB-AB-1A DRYER WELD TB-AB-1B DRYER WELD TB-AB-2A DRYER WELD TB-AB-2B DRYER WELD TB-AB-3A DRYER WELD TB-AB-3B to PLA-7047 Page 5 of26 License Condition 2.C. (20) (f)

Susquehanna Unit 2 Steam Dryer Inspection Results Method Inspection Inspection Condition Description Disposition Date Result Report (If Rl)

VT-1 18-Apr-13 NRI VT-1 16-Apr-13 NRI VT-1 19-Apr-13 NRI VT-1 19-Apr-13 NRI VT-1 22-Apr-13 NRI VT-1 21-Apr-13 NRI VT-1 20-Apr-13 NRI VT-1 20-Apr-13 NRI VT-1 21-Apr-13 NRI VT-1 20-Apr-13 NRI VT-1 21-Apr-13 NRI VT-1 20-Apr-13 NRI VT-1 21-Apr-13 NRI VT-1 21-Apr-13 NRI VT-1 21-Apr-13 NRI VT-1 22-Apr-13 NRI VT-1 18-Apr-13 NRI VT-1 18-Apr-13 NRI VT-1 18-Apr-13 NRI VT-1 18-Apr-13 NRI VT-1 18-Apr-13 NRI VT-1 18-Apr-13 NRI

Component Name DRYER WELD TB-AB-4A DRYER WELD TB-AB-4B DRYER WELD TB-AB-5A DRYER WELD TB-AB-5B DRYER WELD TB-AB-6A DRYER WELD TB-AB-6B DRYER WELD TB-BC-IA DRYER WELD TB-BC-1B DRYER WELD TB-BC-2A DRYER WELD TB-BC-2B DRYER WELD TB-BC-3A DRYER WELD TB-BC-3B DRYER WELD TB-BC-4A DRYER WELD TB-BC-4B DRYER WELD TB-BC-5A DRYER WELD TB-BC-5B DRYER WELD TB-BC-6A DRYER WELD TB-BC-6B DRYER WELD TB-BC-7A DRYER WELD TB-BC-7B DRYER WELD TB-BC-8A DRYER WELD TB-BC-8B to PLA-7047 Page 6 of26 License Condition 2.C. (20) (f)

Susquehanna Unit 2 Steam Dryer Inspection Results Method Inspection Inspection Condition Description Disposition Date Result Report (If Rl)

VT-1 18-Apr-13 NRI VT-1 18-Apr-13 NRI VT-1 18-Apr-13 NRI VT-1 18-Apr-13 NRI VT-1 18-Apr-13 NRI VT-1 18-Apr-13 NRI VT-1 18-Apr-13 NRI VT-1 18-Apr-13 NRI VT-1 18-Apr-13 NRI VT-1 18-Apr-13 NRI VT-1 18-Apr-13 NRI VT-1 18-Apr-13 NRI VT-1 18-Apr-13 NRI VT-1 18-Apr-13 NRI VT-1 18-Apr-13 NRI VT-1 18-Apr-13 NRI VT-1 18-Apr-13 NRI VT-1 18-Apr-13 NRI VT-1 18-Apr-13 NRI VT-1 18-Apr-13 NRI VT-1 18-Apr-13 NRI VT-1 18-Apr-13 NRI

Component Name DRYER WELD TB-CD-1A DRYER WELD TB-CD-lB DRYER WELD TB-CD-2A DRYER WELD TB-CD-2B DRYER WELD TB-CD-3A DRYER WELD TB-CD-3B DRYER WELD TB-CD-4A DRYER WELD TB-CD-4B DRYER WELD TB-CD-5A DRYER WELD TB-CD-5B DRYER WELDTB-DE-1A DRYER WELD TB-DE-1B DRYER WELD TB-DE-2A DRYER WELD TB-DE-2B DRYER WELD TB-DE-3A DRYER WELD TB-DE-3B DRYER WELD TB-DE-4A DRYER WELD TB-DE-4B DRYER WELD TB-DE-5A DRYER WELD TB-DE-5B DRYER WELD TB-DE-6A DRYER WELD TB-DE-6B to PLA-7047 Page 7 of26 License Condition 2.C. (20) (f)

Susquehanna Unit 2 Steam Dryer Inspection Results Method Inspection Inspection Condition Description Disposition Date Result Report (If Rl)

VT-1 18-Apr-13 NRI VT-1 17-Apr-13 NRI VT-1 18-Apr-13 NRI VT-1 17-Apr-13 NRI VT-1 18-Apr-13 NRI VT-1 18-Apr-13 NRI VT-1 18-Apr-13 NRI VT-1 18-Apr-13 NRI VT-1 18-Apr-13 NRI VT-1 18-Apr-13 NRI VT-1 17-Apr-13 NRI VT-1 17-Apr-13 NRI VT-1 17-Apr-13 NRI VT-1 17-Apr-13 NRI VT-1 17-Apr-13 NRI VT-1 17-Apr-13 NRI VT-1 17-Apr-13 NRI VT-1 19-Apr-13 NRI VT-1 17-Apr-13 NRI VT-1 18-Apr-13 NRI VT-1 17-Apr-13 NRI VT-1 17-Apr-13 NRI

Component Name DRYER WELD TB-DE-7A DRYER WELD TB-DE-7B DRYER WELD TB-DE-8A DRYER WELD TB-DE-8B DRYER WELD TB-EF-1A DRYER WELD TB-EF-1B DRYER WELD TB-EF-2A DRYER WELD TB-EF-2B DRYER WELD TB-EF-3A DRYER WELD TB-EF-3B DRYER WELD TB-EF-4A DRYER WELD TB-EF-4B DRYER WELD TB-EF-5A DRYER WELD TB-EF-5B DRYER WELD TB-EF-6A DRYER WELD TB-EF-6B DRYER WELD VS-A-1 DRYER WELD VS-A-2 DRYER WELD VS-B-1 DRYER WELD VS-B-2 DRYER WELD VS-C-1 DRYER WELD VS-C-2 to PLA-7047 Page 8 of26 License Condition 2.C. (20) (f)

Susquehanna Unit 2 Steam Dryer Inspection Results Method Inspection Inspection Condition Description Disposition Date Result Report (If Rl)

VT-1 17-Apr-13 NRI VT-1 17-Apr-13 NRI VT-1 17-Apr-13 NRI VT-1 17-Apr-13 NRI VT-1 17-Apr-13 NRI VT-1 17-Apr-13 NRI VT-1 17-Apr-13 NRI VT-1 17-Apr-13 NRI VT-1 17-Apr-13 NRI VT-1 17-Apr-13 NRI VT-1 17-Apr-13 NRI VT-1 17-Apr-13 NRI VT-1 17-Apr-13 NRI VT-1 17-Apr-13 NRI VT-1 17-Apr-13 NRI VT-1 17-Apr-13 NRI VT-1 20-Apr-13 NRI VT-1 20-Apr-13 NRI VT-1 20-Apr-13 NRI VT-1 20-Apr-13 NRI VT-1 20-Apr-13 NRI VT-1 21-Apr-13 NRI

Component Name DRYER WELD VS-D-1 DRYER WELD VS-D-2 DRYER WELD VS-E-1 DRYER WELD VS-E-2 DRYER WELD VS-F-1 DRYER WELD VS-F-2 DRYER WELD SN-B-1 DRYER WELD SN-B-1 DRYER WELD SN-B-2 DRYER WELD SN-C-1 DRYER WELD SN-C-1 DRYER WELD SN-C-2 DRYER WELD SN-D-1 DRYER WELD SN-D-2 DRYER WELD SN-E-1 DRYER WELD SN-E-2 DRYER WELD 90 DEG COVER PLATE DRYER WELD 90 DEG COVER PLATE DRYER WELD 270 DEG COVER PLATE DRYER WELD 270 DEG COVER PLATE to PLA-7047 Page 9 of26 License Condition 2.C. (20) (f)

Susquehanna Unit 2 Steam Dryer Inspection Results Method Inspection Inspection Condition Description Disposition Date Result Report (HRI)

VT-1 20-Apr-13 NRI VT-1 21-Apr-13 NRI VT-1 20-Apr-13 NRI VT-1 21-Apr-13 NRI VT-1 20-Apr-13 NRI VT-1 21-Apr-13 NRI VT-1 20-Apr-13 NRI VT-1 26-Apr-13 NRI VT-1 20-Apr-13 NRI VT-1 24-Apr-13 NRI VT-1 20-Apr-13 NRI VT-1 21-Apr-13 NRI VT-1 20-Apr-13 NRI VT-1 21-Apr-13 NRI VT-1 20-Apr-13 NRI VT-1 21-Apr-13 NRI VT-1 23-Apr-13 NRI VT-1 19-Apr-13 NRI VT-1 20-Apr-13 NRI VT-1 23-Apr-13 NRI

Component Name DRYER HOOD A DRYER HOOD A DRYER HOOD A DRYERHOODF DRYERHOODF DRYERHOODB DRYERHOODD DRYERHOODE DRYERHOODC DRYERHOODC DRYER WELD ER-A-I DRYER WELD ER-A-I DRYER WELD ER-A-2 DRYER WELD ER-B-1 DRYER WELD ER-B-2 DRYER WELD ER-C-1 DRYER WELD ER-C-2 to PLA-7047 Page 10 of 26 License Condition 2.C. (20) (f)

Susquehanna Unit 2 Steam Dryer Inspection Results Method Inspection Inspection Condition Description Disposition Date Result Report (If Rl)

VT-3 25-Apr-13 RI 1697522 TWO AREAS OF USE-AS-IS INTEREST NOTED AS DISCOLORATION, SWIRL PATTERNS AND SURFACE ROUGHNESS MEASURING 6" AND 5" IN WIDTH VT-3 29-Apr-13 NRI VT-3 01-May-13 NRI VT-3 23-Apr-13 NRI VT-3 01-May-13 RI 1699122 TWO AREAS OF USE-AS-IS INTEREST DISPLAYING SWIRL PATTERNS VT-3 23-Apr-13 NRI VT-3 23-Apr-13 NRI VT-3 23-Apr-13 NRI VT-3 23-Apr-13 NRI VT-3 03-May-13 NRI VT-1 22-Apr-13 NRI VT-1 22-Apr-13 NRI VT-1 22-Apr-13 NRI VT-1 22-Apr-13 NRI VT-1 22-Apr-13 NRI VT-1 22-Apr-13 NRI VT-1 22-Apr-13 NRI

Component Name DRYER WELD ER-D-1 DRYER WELD ER-D-2 DRYER WELD ER-E-I DRYER WELD ER-E-2 DRYER WELD ER-F-1 DRYER WELD ER-F-2 DRYER HOOD A 0 DEG SEAM WELD DRYER HOOD A 180 DEG SEAM WELD DRYER HOOD A UPPER HORIZONTAL WELD DRYER HOOD F UPPER HORIZONTAL WLED DRYER HOOD F 0 DEG SEAM WELD DRYER HOOD F 180 DEG SEAM WELD DRYER HOOD B 0 DEG SEAM WELD DRYER HOOD B 180 DEG SEAM WELD DRYER HOOD B CENTER SEAM WELD DRYER HOOD C 0 DEG SEA WELD DRYER HOOD C 180 DEG SEAM WELD to PLA-7047 Page 11 of 26 License Condition 2.C. (20) (f)

Susquehanna Unit 2 Steam Dryer Inspection Results Method Inspection Inspection Condition Description Disposition Date Result Report (If Rl)

VT-1 22-Apr-13 NRI VT-1 22-Apr-13 NRI VT-1 22-Apr-13 NRI VT-1 22-Apr-13 NRI VT-1 22-Apr-13 NRI VT-1 22-Apr-13 NRI VT-1 17-Apr-13 NRI VT-1 19-Apr-13 NRI VT-1 19-Apr-13 NRI VT-1 19-Apr-13 NRI VT-1 19-Apr-13 NRI VT-1 19-Apr-13 NRI VT-1 19-Apr-13 NRI VT-1 19-Apr-13 NRI VT-1 19-Apr-13 NRI VT-1 19-Apr-13 NRI VT-1 19-Apr-13 NRI

Component Name DRYER HOOD C CENTER SEAM WELD DRYER HOOD D 0 DEG SEAM WELD DRYER HOOD D 180 DEG SEAM WELD DRYER HOOD D CENTER SEAM WELD DRYER HOOD E 0 DEG SEAM WELD DRYER HOOD E 180 DEG SEAM WELD DRYER HOOD E CENTER SEAM WELD DRYER LUG LL-A 40 DEG UPPER BRACKET DRYER LUG LL-A 40 DEG MIDDLE BRACKET DRYER LUG LL-A 40 DEG LOWER BRACKET DRYER LUG LL-B 140 DEG UPPER BRACKET DRYER LUG LL-B 140 DEG MIDDLE BRACKET DRYER LUG LL-B 140 DEG LOWER BRACKET DRYER LUG LL-C 220 DEG UPPER BRACKET to PLA-7047 Page 12 of 26 License Condition 2.C. (20) (f)

Susquehanna Unit 2 Steam Dryer Inspection Results Method Inspection Inspection Condition Description Disposition Date Resnlt Report (ffRI)

VT-1 19-Apr-13 NRI VT-1 19-Apr-13 NRI VT-1 19-Apr-13 NRI VT-1 19-Apr-13 NRI VT-1 19-Apr-13 NRI VT-1 19-Apr-13 NRI VT-1 19-Apr-13 NRI VT-1 19-Apr-13 NRI VT-1 19-Apr-13 NRI VT-1 19-Apr-13 NRI VT-1 19-Apr-13 NRI VT-1 19-Apr-13 NRI VT-1 16-Apr-13 RI 1692786 INDICATION USE-AS-IS REMOVED BY FLAPPING IN 2011 IS VISIBLE MEASURING 5/8 INCHES IN 2013 VT-1 16-Apr-13 NRI

Component Name DRYER LUG LL-C 220 DEG MIDDLE BRACKET DRYER LUG LL-C 220 DEG LOWER BRACKET DRYER LUG LL-D 320 DEG UPPER BRACKET DRYER LUG LL-D 320 DEG MIDDLE BRACKET DRYER LUG LL-D 320 DEG LOWER BRACKET DRYER BASE PLATE E-F DRYER BASE PLATE A-B DRYER BASE PLATE D-E DRYER BASE PLATE C-B DRYER HOOD A TROUGH DRYER HOOD A TROUGH DRYER HOOD F TROUGH DRYER HOOD F TROUGH DRYER HOOD B TROUGH DRYER HOOD B TROUGH DRYER HOOD E TROUGH DRYER HOOD E TROUGH to PLA-7047 Page 13 of 26 License Condition 2.C. (20) (f)

Susquehanna Unit 2 Steam Dryer Inspection Results Method Inspection Inspection Condition Description Disposition Date Result Report (If Rl)

VT-1 17-Apr-13 NRI VT-1 17-Apr-13 RI 1692786 IGSCC USE-AS-IS INDICATION IN UPPER HEAT AFFECTED ZONE 7

/16 INCHES LONG VT-1 17-Apr-13 NRI VT-1 17-Apr-13 RI 1692786 IGSCC USE-AS-IS INDICATION IN UPPER HEAT AFFECTED ZONE 1

/2 INCHES LONG VT-1 17-Apr-13 NRI VT-1 16-Apr-13 NRI VT-1 16-Apr-13 NRI VT-1 16-Apr-13 NRI VT-1 16-Apr-13 NRI VT-1 16-Apr-13 NRI VT-1 16-Apr-13 NRI VT-1 17-Apr-13 NRI VT-1 17-Apr-13 NRI VT-1 16-Apr-13 NRI VT-1 16-Apr-13 NRI VT-1 17-Apr-13 NRI VT-1 17-Apr-13 NRI

Component Name DRYER HOOD C TROUGH DRYER HOOD C TROUGH DRYER HOOD D TROUGH DRYER HOOD D TROUGH DRYER WELD VS-B-1 INTERIOR DRYER WELD VS-B-2 INTERIOR DRYER WELD VS-E-1 INTERIOR DRYER WELD VS-E-2 INTERIOR DRYER WELD VS-D-2 INTERIOR DRYER WELDVS-D-1 INTERIOR DRYER WELD VS-C-2 INTERIOR DRYER WELD VS-C-1 INTERIOR DRYER WELD PLATE TO RING 180DEG DRYER WELD PLATE TO RING 180DEG DRYER WELD PLATE TO RING 180DEG DRYER WELD PLATE TO RINGODEG to PLA-7047 Page 14 of 26 License Condition 2.C. (20) (f)

Susquehanna Unit 2 Steam Dryer Inspection Results Method Inspection Inspection Condition Description Disposition Date Result Report (If Rl)

VT-1 16-Apr-13 NRI VT-1 16-Apr-13 NRI VT-1 17-Apr-13 NRI VT-1 17-Apr-13 NRI VT-1 20-Apr-13 NRI VT-1 21-Apr-13 NRI VT-1 20-Apr-13 NRI VT-1 21-Apr-13 NRI VT-1 21-Apr-13 NRI VT-1 20-Apr-13 NRI VT-1 21-Apr-13 NRI VT-1 20-Apr-13 NRI VT-1 01-May-13 NRI VT-1 22-Apr-13 NRI VT-1 22-Apr-13 NRI VT-1 22-Apr-13 NRI

Component Name DRYER WELD PLATE TO RINGODEG DRYER WELD PLATE TO RINGODEG DRYER WELD VS-A-1 INTERIOR DRYER WELD VS-A-2 INTERIOR DRYER WELD VS-F-1 INTERIOR DRYER WELD VS-F-2 INTERIOR DRYER WELD SN-C-1 INTERIOR DRYER WELD SN-C-2 INTERIOR DRYER WELD SN-D-1 INTERIOR DRYER WELD SN-D-2 INTERIOR DRYER WELD SN-B-1 INTERIOR DRYER WELD SN-B-2 INTERIOR DRYER WELD SN-B-2 INTERIOR DRYER WELD SN-E-1 INTERIOR DRYER WELD SN-E-2 INTERIOR to PLA-7047 Page 15 of 26 License Condition 2.C. (20) (f)

Susquehanna Unit 2 Steam Dryer Inspection Results Method Inspection Inspection Condition Description Disposition Date Result Report (If Rl)

VT-1 01-May-13 NRI VT-1 22-Apr-13 NRI VT-1 20-Apr-13 NRI VT-1 21-Apr-13 NRI VT-1 21-Apr-13 NRI VT-1 21-Apr-13 NRI VT-1 20-Apr-13 NRI VT-1 21-Apr-13 NRI VT-1 21-Apr-13 NRI VT-1 21-Apr-13 NRI VT-1 20-Apr-13 NRI VT-1 20-Apr-13 NRI VT-1 25-Apr-13 NRI VT-1 21-Apr-13 NRI VT-1 22-Apr-13 NRI

Component Name DRYER WELD SN-E-2 INTERIOR DRYER SKIRT WELD 45 DEG DRYER SKIRT WELD 135 DEG DRYER SKIRT WELD 225 DEG DRYER SKIRT WELD 315 DEG SKIRT PANEL 180 DEG LEFT SIDE SKIRT PANEL 180 DEG LEFT SIDE SKIRT PANEL 180 DEG RIGHT SIDE SKIRT PANEL TO MID RING 180 DEG SKIRT PANEL TO LOWER SUPPORT RING 180 DEG SKIRT PANEL 0 DEG RIGHT SIDE SKIRT PANEL 0 DEG LEFT SIDE to PLA-7047 Page 16 of 26 License Condition 2.C. (20) (f)

Susquehanna Unit 2 Steam Dryer Inspection Results Method Inspection Inspection Condition Description Disposition Date Result Report (If RI)

VT-1 25-Apr-13 NRI VT-1 17-Apr-13 NRI VT-1 15-Apr-13 RI 1692786 NEW GROWTH IN USE-AS-IS PREVIOUSLY IDENTIFIED IGSCC INDICATIONS VT-1 18-Apr-13 NRI VT-1 18-Apr-13 NRI VT-1 18-Apr-13 NRI VT-1 21-Apr-13 NRI VT-1 17-Apr-13 NRI VT-1 17-Apr-13 NRI VT-1 18-Apr-13 NRI VT-1 16-Apr-13 NRI VT-1 16-Apr-13 NRI

Component Name SKIRT PANEL 0 DEG LEFT SIDE SKIRT PANEL TO MID RING ODEG SKIRT PANEL TO LOWER SUPPORT RING 0 DEG DRYER SKIRT-00-90 DEGREES DRYER SKIRT-90-180 DEGREES DRYER SKIRT-270-360 DEGREES to PLA-7047 Page 17 of 26 License Condition 2.C. (20) (f)

Susquehanna Unit 2 Steam Dryer Inspection Results Method Inspection Inspection Condition Description Disposition Date Result Report (If RI)

VT-1 21-Apr-13 RI 1697229 TWO USE-AS-IS INDICATIONS ON ID DRYER AT THE INTERSECTION OF THE SKIRT WELD TPIECEANDT PIECE TO SUPPORT RING AREA VT-1 16-Apr-13 NRI VT-1 16-Apr-13 NRI VT-3 21-Apr-13 RI 1697237 NO CHANGE IN USE-AS-IS ORIGINAL ANOMALY FROM 2011. NEW INDICATION ON THE MID SUPPORT RING AT40 DEGREES APPROXIMATELY 0.25 INCHES.

SURFACE ANOMALY AT 42 DEGREES VT-3 22-Apr-13 RI 1697451 NO CHANGE IN USE-AS-IS GOUGES AND ANOMALY SEEN IN 2011. TWO NEW GOUGES AT 180 DEGREES. FOUR NEW ANOMALIES AT 98, 97,96 DGREES OF THE SKIRT VT-3 24-Apr-13 NRI

Component Name DRYER SKIRT-270-000 DRYER HOOD A DRAIN PIPEO DEG DRYER HOOD A DRAIN PIPEODEG DRYER HOOD A DRAIN PIPEODEG DRYER HOOD A DRAIN PIPE 180 DEG DRYER HOOD A DRAIN PIPE 180 DEG DRYER HOOD A DRAIN PIPE 180 DEG DRYER HOOD B DRAIN PIPEODEG DRYER HOOD B DRAIN PIPEO DEG DRYER HOOD B DRAIN PIPE 0 DEG DRYER HOOD B DRAIN PIPE 180 DEG DRYER HOOD B DRAIN PIPE 180DEG DRYER HOOD B DRAIN PIPE 180DEG DRYER HOOD C DRAIN PIPEODEG DRYER HOOD C DRAIN PIPEO DEG to PLA-7047 Page 18 of 26 License Condition 2.C. (20) (f)

Susquehanna Unit 2 Steam Dryer Inspection Results Method Inspection Inspection Condition Description Disposition Date Result Report (If Rl)

.vT-3 24-Apr-13 RI 1700339 MULTIPLE DRYER USE-AS-IS SKIRT SURFACE ANOMALIES VT-1 17-Apr-13 NRI VT-1 17-Apr-13 NRI VT-1 17-Apr-13 NRI VT-1 18-Apr-13 NRI VT-1 18-Apr-13 NRI VT-1 18-Apr-13 NRI VT-1 17-Apr-13 NRI VT-1 17-Apr-13 NRI VT-1 17-Apr-13 NRI VT-1 18-Apr-13 NRI VT-1 18-Apr-13 NRI VT-1 18-Apr-13 NRI VT-1 17-Apr-13 NRI VT-1 17-Apr-13 NRI

Component Name DRYER HOOD C DRAIN PIPEODEG DRYER HOOD C DRAIN PIPE 180 DEG DRYER HOOD C DRAIN PIPE 180 DEG DRYER HOOD C DRAIN PIPE 180 DEG DRYER HOOD D DRAIN PIPE ODEG DRYER HOOD D DRAIN PIPEODEG DRYER HOOD D DRAIN PIPEODEG DRYER HOOD D DRAIN PIPE 180 DEG DRYER HOOD D DRAIN PIPE 180 DEG DRYER HOOD D DRAIN PIPE 180 DEG DRYER HOOD E DRAIN PIPE ODEG DRYER HOOD E DRAIN PIPE ODEG DRYER HOOD E DRAIN PIPEODEG DRYER HOOD E DRAIN PIPE 180 DEG DRYER HOOD E DRAIN PIPE 180 DEG to PLA-7047 Page 19 of 26 License Condition 2.C. (20) (f)

Susquehanna Unit 2 Steam Dryer Inspection Results Method Inspection Inspection Condition Description Disposition Date Result Report (If Rl)

VT-1 17-Apr-13 NRI VT-1 18-Apr-13 NRI VT-1 18-Apr-13 NRI VT-1 18-Apr-13 NRI VT-1 17-Apr-13 NRI VT-1 17-Apr-13 NRI VT-1 17-Apr-13 NRl VT-1 18-Apr-13 NRI VT-1 18-Apr-13 NRI VT-1 18-Apr-13 NRI VT-1 18-Apr-13 NRI VT-1 17-Apr-13 NRI VT-1 17-Apr-13 NRI VT-1 18-Apr-13 NRI VT-1 18-Apr-13 NRI

Component Name DRYER HOOD E DRAIN PIPE 180 DEG DRYER HOOD F DRAIN PIPEODEG DRYER HOOD F DRAIN PIPEO DEG DRYER HOOD F DRAIN PIPE ODEG DRYER HOOD F DRAIN PIPE 180 DEG DRYER HOOD F DRAIN PIPE 180 DEG DRYER HOOD F DRAIN PIPE 180 DEG DRYER WELD DC-A-4 DRYER WELD DC-B-4 DRYER WELD DC-C-4 DRYER WELD DC-D-4 LOWER SKIRT RING 0-180 DEG LOWER SKIRT RING 0-180 DEG LOWER SKIRT RING 180-360 DEG LOWER SKIRT RING 180-360DEG MID SUPPORT RING LOWER WELD 0-180 DEG to PLA-7047 Page 20 of26 License Condition 2.C. (20) (f)

Susquehanna Unit 2 Stearn Dryer Inspection Results Method Inspection Inspection Condition Description Disposition Date Result Report (If Rl)

VT-1 18-Apr-13 NRI VT-1 18-Apr-13 NRI VT-1 18-Apr-13 NRI VT-1 18-Apr-13 NRI VT-1 18-Apr-13 NRI VT-1 18-Apr-13 NRI VT-1 18-Apr-13 NRI VT-1 17-Apr-13 NRI VT-1 17-Apr-13 NRI VT-1 18-Apr-13 NRI VT-1 18-Apr-13 NRI VT-1 23-Apr-13 NRI VT-1 23-Apr-13 NRI VT-1 24-Apr-13 NRI VT-1 24-Apr-13 NRI VT-1 23-Apr-13 NRI

Component Name MID SUPPORT RING LOWER WELD 0-180 DEG MID SUPPORT RING LOWER WELD 180-360 DEG MID SUPPORT RING LOWER WELD 180-360 DEG DRYER WELD TB-CD-6B DRYER WELD TB-CD-6A TRANS BRACE DRYER TRANS BRACE BRACKET I DRYER TRANS BRACE BRACKET2 DRYER TRANS BRACE BRACKET3 DRYER TRANS BRACE BRACKET4 DRYER TRANS BRACE BRACKETS DRYER TRANS BRACE BRACKET6 DRYER HOOD B UPPER HORIZONTAL WELD DRYER HOOD E UPPER HORIZONTAL WELD DRYER HOOD C UPPER HORIZONTAL WELD DRYER HOOD D UPPER HORIZONTAL WELD to PLA-7047 Page 21 of 26 License Condition 2.C. (20) (f)

Susquehanna Unit 2 Steam Dryer Inspection Results Method Inspection Inspection Condition Description Disposition Date Result Report (If Rl)

VT-1 22-Apr-13 NRI VT-1 23-Apr-13 NRI VT-1 24-Apr-13 NRI VT-1 18-Apr-13 NRI VT-1 18-Apr-13 NRI VT-3 19-Apr-13 NRI VT-1 19-Apr-13 NRI VT-1 19-Apr-13 NRI VT-1 19-Apr-13 NRI VT-1 19-Apr-13 NRI VT-1 19-Apr-13 NRI VT-1 19-Apr-13 NRI VT-1 20-Apr-13 NRI VT-1 20-Apr-13 NRI VT-1 20-Apr-13 NRI VT-1 19-Apr-13 NRI

Component Name DRYER HOOD B 0 DEG DIVIDER PLATE DRYER HOOD B MID DIVIDER PLATE DRYER HOOD B 180 DEG DIVIDER PLATE DRYER HOOD C 0 DEG DIVIDER PLATE DRYER HOOD C MID DIVIDER PLATE DRYER HOOD C 180 DEG DIVIDER PLATE DRYER HOOD D 0 DEG DIVIDER PLATE DRYER HOOD D MID DEG DIVIDER PLATE DRYER HOOD D 180 DEG DIVIDER PLATE DRYER HOOD E 0 DEG DIVIDER PLATE DRYER HOOD E MID DIVIDER PLATE DRYER HOOD E 180 DEG DIVIDER PLATE DRYER HOOD A 0 DEG DIVIDER PLATE DRYER HOOD A 180 DEG DIVIDER PLATE DRYER HOOD F 0 DEG DIVIDER PLATE to PLA-7047 Page 22 of26 License Condition 2.C. (20) (f)

Susquehanna Unit 2 Steam Dryer Inspection Results Method Inspection Inspection Condition Description Disposition Date Result Report (If RI)

VT-1 19-Apr-13 NRI VT-1 19-Apr-13 NRI VT-1 19-Apr-13 NRI VT-1 20-Apr-13 NRI VT-1 20-Apr-13 NRI VT-1 20-Apr-13 NRI VT-1 19-Apr-13 NRI VT-1 20-Apr-13 NRI VT-1 20-Apr-13 NRI VT-1 20-Apr-13 NRI VT-1 20-Apr-13 NRI VT-1 20-Apr-13 NRI VT-1 19-Apr-13 NRI VT-1 19-Apr-13 NRI VT-1 20-Apr-13 NRI

Component Name DRYER HOOD F 180 DEG DIVIDER PLATE DRYER HOOD B 0 DEG HOOD SUPPORT DRYER HOOD B MID HOOD SUPPORT DRYER HOOD B 180 DEG HOOD SUPPORT DRYER HOOD C 0 DEG HOOD SUPPORT DRYER HOOD C MID HOOD SUPPORT DRYER HOOD C 180 DEG HOOD SUPPORT DRYER HOOD D 0 DEG HOOD SUPPORT DRYER HOOD D MID HOOD SUPPORT DRYER HOOD D 180 DEG HOOD SUPPORT DRYER HOOD E 0 DEG HOOD SUPPORT DRYER HOOD E MID HOOD SUPPORT DRYER HOOD E 180 DEG HOOD SUPPORT DRYER HOOD A 0 DEG HOOD SUPPORT DRYER HOOD A 180 DEG HOOD SUPPORT to PLA-7047 Page 23 of26 License Condition 2.C. (20) (f)

Susquehanna Unit 2 Steam Dryer Inspection Results Method Inspection Inspection Condition Description Disposition Date Result Report (If Rl)

VT-1 20-Apr-13 NRI VT-1 20-Apr-13 NRI VT-1 20-Apr-13 NRI VT-1 20-Apr-13 NRI VT-1 20-Apr-13 NRI VT-1 20-Apr-13 NRI VT-1 20-Apr-13 NRI VT-1 20-Apr-13 NRI VT-1 20-Apr-13 NRI VT-1 20-Apr-13 NRI VT-1 21-Apr-13 NRI VT-1 21-Apr-13 NRI VT-1 21-Apr-13 NRI VT-1 19-Apr-13 NRI VT-1 19-Apr-13 NRI

Component Name DRYER HOOD F 0 DEG HOOD SUPPORT DRYER HOOD F 180 DEG HOOD SUPPORT DRYER LIFTING ROD 40 DEG LIFT ROD TO LIFT ANCHOR WELD DRYER 40-DEG LIFTING EYE WELDS DRYER LIFTING ROD 140 DEG LIFT ROD TO LIFT ANCHOR WELD DRYER 140-DEG LIFTING EYE WELDS DRYER LIFTING ROD 220 DEG LIFT ROD TO LIFT ANCHOR WELD DRYER 220-DEG LIFTING EYE WELDS DRYER LIFTING ROD 320 DEG LIFT ROD TO LIFT ANCHOR WELD DRYER 320-DEG LIFTING EYE WELDS DRYER 320-DEG LIFT ANCHOR WELDS DRYER 320-DEG LIFT ANCHOR WELDS to PLA-7047 Page 24 of26 License Condition 2.C. (20) (f)

Susquehanna Unit 2 Steam Dryer Inspection Results Method Inspection Inspection Condition Description Disposition Date Result Report (If Rl)

VT-1 21-Apr-13 NRI VT-1 21-Apr-13 NRI VT-1 17-Apr-13 NRI VT-3 16-Apr-13 NRI VT-1 17-Apr-13 NRI VT-3 18-Apr-13 RI 1692786 TWO OF FOUR USE-AS-IS FILLET WELDS ARE CRACKED: 0 DEGREE WELD AND 90 DEGREE WELD VT-1 18-Apr-13 NRI VT-3 16-Apr-13 NRI VT-1 18-Apr-13 NRI VT-3 17-Apr-13 NRI VT-1 18-Apr-13 NRI VT-1 21-Apr-13 NRI

Component Name DRYER 40-DEG LIFT ANCHOR WELDS DRYER 40-DEG LIFT ANCHOR WELDS DRYER 220-DEG LIFT ANCHOR WELDS DRYER 220-DEG LIFT ANCHOR WELDS DRYER 140-DEG LIFT ANCHOR WELDS DRYER 140-DEG LIFT ANCHOR WELDS DRYER LOWER GUIDE 0 DEG DRYER LOWER GUIDE 180 DEG DRYER 40-DEG LIFTING LUG TO EYE FILLET WELDS DRYER 140-DEG LIFTING LUG TO EYE FILLET WELDS DRYER 220-DEG LIFTING LUG TO EYE FILLET WELDS DRYER 320-DEG LIFTING LUG TO EYE FILLET WELDS to PLA-7047 Page 25 of 26 License Condition 2.C. (20) (f)

Susquehanna Unit 2 Steam Dryer Inspection Results Method Inspection Inspection Condition Description Disposition Date Result Report (IfRI)

VT-1 20-Apr-13 NRI VT-1 17-Apr-13 NRI VT-1 21-Apr-13 NRI VT-1 18-Apr-13 NRI VT-1 17-Apr-13 NRI VT-1 20-Apr-13 NRI VT-3 20-Apr-13 NRI VT-3 20-Apr-13 NRI VT-1 19-Apr-13 NRI VT-1 19-Apr-13 RI 1693833 TWOOFFOUR USE-AS-IS FILLET WELDS ARE CRACKED: 0 DEGREE WELD AND90DEGREE WELD VT-1 16-Apr-13 NRI VT-1 17-Apr-13 RI 1692786 90 DEGREE FILLET USE-AS-IS WELD IS CRACKED MEASURING 1.75 INCHES

Component Name DRYER SKIRT 4 DEG MID SUPPORT RING ID DRYER SKIRT DEFECT REMOVAL AREA to PLA-7047 Page 26 of26 License Condition 2.C. (20) (f)

Susquehanna Unit 2 Steam Dryer Inspection Results Method Inspection Inspection Condition Description Disposition Date Resnlt Report (If Rl)

VT-1 15-Apr-13 RI NA DRILL HOLE NOCR REPAIR FROM GENERATE-2011-ID OF DRYER NO CHANGE IN CONDITION FROM 2011 VT-1 16-Apr-13 RI NA DRILL HOLE NOCR REPAIR FROM GENERATE-2011-0D OF NO CHANGE DRYER IN CONDITION FROM 2011