NRC Generic Letter 82-32, Draft Steam Generator Report (SAI)

From kanterella
(Redirected from NRC Generic Letter 82-32)
Jump to navigation Jump to search

text

December 29, 1982

TO ALL PRESSURIZED WATER REACTOR PLANT LICENSEES

Gentlemen:

SUBJECT: POTENTIAL STEAM GENERATOR RELATED GENERATED REQUIREMENTS (GENERIC LETTER NO. 82-32)

The NRC staff has identified potential steam generator related generic requirements and is currently subjecting them to a value impact analysis. A major element if the staff's value impact will be an analysis being prepared by our contractor, Science Applications, Inc. A copy of these draft report is provided for your review and will be modified to consider multiple steam generator tube ruptures in combination with other events along with single tube rupture scenarios.

Any comments you may care to make, either individually or through Owners Groups, on the SAI report and on the probability and consequences of multiple tube ruptures scenarios would be considered in the staff's final value impact analysis if they can be provided within 30 days of the date of this letter.

Sincerely,


Darrell G. Eisenhut, Director Division of Licensing

Enclosure:

SAI Report


8208190263