ML24338A095

From kanterella
Jump to navigation Jump to search
Updated Agenda for January 2025 Industry/Nrc NDE Technical Information Exchange Public Meeting
ML24338A095
Person / Time
Issue date: 01/23/2025
From: Ali Rezai
NRC/NRR/DNRL/NPHP
To:
References
Download: ML24338A095 (1)


Text

AGENDA JANUARY 22-23, 2025 ANNUAL NRC-INDUSTRY NDE TECHNICAL INFORMATION EXCHANGE (TIE) PUBLIC MEETING (HYBRID)

NRC HEADQUARTERS, ROCKVILLE, MD Room: OWFN-01G05 Wednesday, January 22, 2025 Time (EDT)

Topic Presenter Presentation ID 8:00 am Introductions and Opening Statements NRC/Industry 8:10 am ASME Code Update including AI/ML Actions Industry 1

8:30 am Industry Performance Demonstration Activities Industry 2

8:50 am MRP Update Industry 3

9:10 am BWRVIP Update Industry 4

9:30 am Training Opportunity: Fundamental Applications of NDE for Managers and Engineers (CBT)

Industry 5

9:50 am Break 10:10 am Recent OE Industry 6

11:00 am EPRI 2025 Workplan: Overview Industry 7

11:20 am Advanced UT for CASS Industry 8

11:40 am Expansion and Refinement of Virtual Mockup Capabilities Industry 9

12:00 pm Lunch 1:00 pm Balance-of-Plant Heat Exchanger and Condenser ET Best Practices Database Industry 10 1:20 pm Tube Support Plate Degradation ET Evaluation Industry 11 1:40 pm AI/ML for Tubing ET Analysis Industry 12 2:00 pm RI-ISI Support, Extension, and Implementation Industry 13 2:20 pm UT in Lieu of RT for Construction/Fabrication Industry 14 2:40 pm NRC Position on UT in Lieu of RT NRC 15 3:00 pm Break 3:20 pm NDE of Novel Repair/Replacement Materials Industry 16 3:40 pm NRC Position on NDE of Novel Repair/Replacement Materials NRC 17 4:00 pm NDE of CFRP Repairs NRC/Industry 18 4:20 pm Importance of Continued NDE Collaboration between EPRI/Industry and NRC/PNNL/ORNL (Discussion)

Industry 19 4:50 pm Public Comments NRC 5:00 pm Adjourn Day 1

Thursday, January 23, 2025 Time (EDT)

Topic Presenter Presentation ID 8:00 am Opening Statements NRC 8:05 am AI/ML for CRDM UT Analysis Industry 20 8:30 am AI/ML for DMW UT Analysis Industry 21 8:50 am AI/ML for Core Shroud and Core Barrel UT Analysis Industry 22 9:10 am Virtual Round Robin Industry 23 9:30 am AI/ML for In-Vessel Visual Analysis Industry 24 9:50 am AI/ML for Manual UT and Other Future Projects Industry 25 10:00 am Break 10:20 am Automated Data Analysis NRC-ORNL 26 10:50 am NRC Position on AI/ML for NDE NRC 27 11:20 am NDE of Electron Beam Welds NRC-PNNL 28 11:40 am Public Comment NRC 11:55 am Closing Statements NRC/Industry 12:00 pm Adjourn 1:00 pm Closed Session Industry/NRC 2:00 pm Closed Session Industry/NRC 3:00 pm Break 3:20 pm Closed Session Industry/NRC 4:20 pm Closed Session Industry/NRC 5:00 pm Adjourn Day 2 AI: Artificial Intelligence ASME: American Society of Mechanical Engineers BWRVIP: Boiling Water Reactor Vessel Internals Program CASS: Cast Austenitic Stainless Steel CBT: Computer-Based Training CFRP: Carbon Fiber-Reinforced Polymer CRDM: Control Rod Drive Mechanism DMW: Dissimilar Metal Weld EPRI: Electric Power Research Institute ET: Eddy Current Testing ML: Machine Learning MRP: Materials Reliability Program NDE: Nondestructive Examination NRC: U.S. Nuclear Regulatory Commission OE: Operating Experience ORNL: Oak Ridge National Laboratory PNNL: Pacific Northwest National Laboratory RI-ISI: Risk-Informed Inservice Inspection RT: Radiographic Testing UT: Ultrasonic Testing