NRC Pre-submittal Meeting October 29, 2024
Meeting Purpose
- Gain alignment on the basis of the additional NRC requested documents from DI&C-ISG-06 Rev 2 Enclosure B.
Agenda
- Introductions - Project Team
- Requested DI&C-ISG-06 Rev 2 Enclosure B documents
- NRC to provide regulatory basis for the requested documents 1
Constellation Energy
- Steve Flickinger, Prin. Reg. Specialist, Corporate Licensing Sargent & Lundy
- Pareez Golub - Project Director, Digital Licensing SME 2
Items submitted as part of the ARP
- 1.3 Approved Topical Report Safety Evaluation
- 1.4 System Description
- 1.5 System Architecture
- 1.7 (Unified Compliance/Conformance Matrix for) IEEE
[Institute of Electrical and Electronics Engineers] Stds 603-1991 and 7-4.3.2-2003
- 1.8 (Changes to) Technical Specifications
- 1.9 Setpoint Methodology and Calculations
- 1.10 Secure Development and Operational Environment 3
Additional documents requested by the NRC
- 1.6 (Summary of) Hardware Equipment Qualification
- 1.11 Software Requirements Specification
- 1.12 Software Design Specification
- 1.13 Design Analysis Reports for Platform Changes
- 1.14 System Response Time Analysis Report
- 1.16 Commercial-Grade Dedication Plan
- 1.17 Quality Assurance Plan for Hardware
- 1.18 (Summary of) Hardware Development Process
- 2.2 As-Manufactured, System Configuration Documentation
- 2.3 Summary Test Reports
- 2.6 System-Level Failure Modes and Effects Analysis
- 2.9 (Summary of) Electromagnetic Interface, Temperature, Humidity, and Seismic Testing Results
- 2.10 Commercial-Grade Dedication Report(s)
- The project team needs to understand the basis of the additional NRC requests to ensure that what we provide in the submittal meets the necessary basis.
4