Text

Holtec Technology Campus, 1 Holtec Blvd, Camden, NJ 08104 HOLTEC INTERNATIONAL August 9th, 2024 Mr. Bernie White Division of Spent Fuel Management Office of Nuclear Material Safety and Safeguards U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 Docket No. 72-1014, Certificate of Compliance (CoC) No. 1014 Telephone (856) 797-0900 Fax(856)797-0909

Subject:

HI-STORM 100 Multipurpose Canister Storage System Amendment 19 Request

Dear Mr. White:

Holtec International herein submits a request to amend Certificate of Compliance (CoC) 72-1014 for the HI-STORM 100 Multipurpose Canister Storage System. The proposed change is to update the Acceptance Criteria and Method of Evaluation (MOE) for the HI-STORM 100 tipover accident described in the FSAR for equipment combinations involving MPCs with Metamic-HT baskets.

Several related minor/editorial changes are also proposed.

A summary of the proposed changes (SOPC), with more detailed description of the change, reason for the change and justification for the change, is provided in Attachment 1. Attachment 2 contains proposed changes for the CoC Appendix D. Attachments 3 and 4 provide proposed changes to the HI-STORM 100 FSAR for both proprietary and non-proprietary versions, respectively. contains a related change to a licensing drawing. All proposed changes m Attachments 2 through 5 are provided in mark-up format to facilitate the Staffs review.

Attachments 6 through 8 contain supporting proprietary documents.

Since some attachments to this letter contain Holtec proprietary information, an affidavit requesting this information be withheld in accordance with 1 0CFR2.390 is included as Attachment

9. If you have any questions or require any additional information, please contact me at 856-797-0900 ext. 3326.

Document ID 5014982 Page 1 of 2

HOLTEC INTERNATIONAL Sincerely,

,~ ~

Denise Elisio Licensing Engineer, Holtec International cc:

(via email)

Holtec Technology Campus, 1 Holtec Blvd, Camden, NJ 08104 Telephone (856) 797-0900 Fax(856)797-0909 Y oira Diaz-Sanabria, USNRC Yen Chen, USNRC Kimberly Manzione, Holtec Attachments: : HI-STORM 100 Amendment 19 Summary of Proposed Changes (non-proprietary) : HI-STORM 100 Amendment 19 Certificate of Compliance, Appendix D (non-proprietary) : HI-STORM 100 FSAR Proposed Revision 25, revised pages (proprietary) : HI-STORM 100 FSAR Proposed Revision 25, revised pages (non-proprietary) : Proposed Licensing DWG-7195 change (proprietary) : HI-2188448R5, Analysis of the Non-Mechanistic Tipover Event of the Loaded HI-STORM lO0S Version E Storage Cask, Appendixes A, B, E, F, H, I, K (proprietary) : HI-2210290R3, Analysis of the Non-Mechanistic Tipover Event of the Loaded HI-STORM 100 Version UVH Storage Cask (proprietary) : HI-2240678R0, Analysis of the Non-Mechanistic Tipover Event of the Loaded HI-STORM 100 Storage Cask (proprietary) : Affidavit in Accordance with 10 CFR 2.390 Document ID 5014982 Page 2 of 2