ML24150A166
| ML24150A166 | |
| Person / Time | |
|---|---|
| Site: | Catawba |
| Issue date: | 05/29/2024 |
| From: | Bell J Engineering Branch 3 |
| To: | Andrews S Duke Energy |
| References | |
| Download: ML24150A166 (1) | |
Text
From:
Jack Bell To:
"Andrews, Sherry E" Cc:
Bob Kellner; "Joe.Smith@duke-energy.com"
Subject:
Request for Information--Catawba HP Environmental Inspection 2024-03 Date:
Wednesday, May 29, 2024 9:50:00 AM Attachments:
Document Request CAT.pdf
- Sherry, Please find attached the Information Request for the upcoming Catawba effluents and REMP inspection the week of July 29th. We would like the documents to us by July 19th but let us know if you need additional time for certain items and we can work with you. The inspectors will be myself and Bob Kellner. We have both been badged at Catawba before, although I know in my case its been over a year.
- Thanks, Jack Bell
Page 1 of 4 Catawba Nuclear Station Radiation Safety Baseline Inspection Initial Information Request Inspection Report: 2024003 During the week of July 29 - August 2, 2024, the NRC will perform a baseline Radiation Safety Inspection at the Catawba Nuclear Station (NRC Inspection Procedures 71124.06, 71124.07, and 71151 (public cornerstone only)).
Experience has shown that this inspection is resource-intensive for both the NRC inspectors and your staff. To minimize the impact to your onsite resources and to ensure a productive inspection, we are requesting in advance documents needed for this activity. It is important that all these documents are up-to-date, and complete, thereby minimizing the number of additional documents requested during the preparation, and/or the onsite portions of the inspection. The NRC requests that these documents be provided to the inspectors no later than July 19, 2024.
If there are any questions about this inspection or the material requested, please contact the lead inspector, Jack Bell at 404-997-4638, or the Engineering Branch 3 Branch Chief, Binoy Desai, at 404-997-4519.
In accordance with Title 10 of the Code of Federal Regulations (10 CFR) 2.390, Public inspections, exemptions, requests for withholding, a copy of this document will be available electronically for public inspection in the NRC Public Document Room, or from the Publicly Available Records component of NRC's Agencywide Documents Access and Management System (ADAMS); accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html.
PAPERWORK REDUCTION ACT STATEMENT This letter contains voluntary information collections that are subject to the Paperwork Reduction Act of 1995 (44 U.S.C. 3501 et seq.). The Office of Management and Budget (OMB) approved these information collections (approval number 3150-0011). The burden to the public for these information collections is estimated to average 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> per response. Send comments regarding this information collection to the FOIA, Library and Information Collection Branch, Office of the Chief Information Officer, Mail Stop: T6-A10M, U.S. Nuclear Regulatory Commission, Washington, DC 20555-0001, or by email to Infocollects.Resource@nrc.gov, and to the Desk Officer, Office of Information and Regulatory Affairs, NEOB-10202, (3150-0011) OMB, Washington, DC 20503.
PUBLIC PROTECTION NOTIFICATION The NRC may not conduct or sponsor, and a person is not required to respond to, a request for information or an information collection requirement, unless the requesting document displays a currently valid Office of Management and Budget control number.
Page 2 of 4 Document Request List Occupational and Public Radiation Safety Cornerstones Inspection Dates:
July 29 - August 2, 2024 Documents Due to Region II by:
July 19, 2024 Inspection Procedures:
IP 71124.06 Gaseous and Liquid Effluent IP 71124.07 Radiological Effluent Monitoring Program (REMP)
IP 71151 Performance Indicator Verification (Public Cornerstone Only)
Lead Inspector and Mailing Address:
Jack Bell U.S. Nuclear Regulatory Commission Senior Health Physicist Region II US NRC Region II ATTN: Jack Bell (404) 997-4638 245 Peachtree Center Ave., N.E jack.bell@nrc.gov Suite 1200 Atlanta, GA 30303 Note: Current version of these documents is expected unless specified otherwise. Secure file server access (Certrec, SharePoint, etc.), or electronic media (CD/DVD), is preferred. To the extent possible, please organize the information as it is arranged below. Experience has shown that poorly organized files can lead to a less efficient inspection and places additional burden on licensee staff. During the inspection, the inspectors may request additional documents. To the extent possible, please organize the information as it is arranged below. Pay attention to the date ranges for the items requested as they may change from item to item. If there are questions regarding the documents requested, or if the documents cannot be provided by the due date, please do not hesitate to contact the lead inspector.
Documentation is requested from May 1, 2021, to present for IPs IP 71124.06, and 71124.07 and from April 1, 2023 to present for IP 71151. We would prefer as much of the information as possible in electronic form. An index of the files is also helpful. For those items requesting a list of documents/areas, the inspector will may select documents/areas from the list for on-site review.
Miscellaneous
- 1. List of primary contacts for each inspection area including names and telephone numbers
- 2. Radiation Protection, and Chemistry organizational charts w/ contact numbers
- 3. Corrective action program procedure(s)
- 4. List of radiation protection and chemistry procedures, including title and number
- 5. Copy of the current Offsite Dose Calculation Manual and Selected Licensee Commitments Manual
Page 3 of 4 71124.06 - Radioactive Gaseous and Liquid Effluent Treatment (Last inspected May 2021)
- 1. Procedures for sampling and controlling radioactive gaseous and liquid effluents to include:
collection, analysis, release, alarm setpoints, offsite dose calculation and evaluation.
- 2. List of changes made to the Offsite Dose Calculation Manual (ODCM), meteorological dispersion or deposition factors, and radioactive effluent processing/discharge systems since May 1, 2021.
- 3. List of out of service (OOS) effluent monitors and duration since May 1, 2021.
- 4. List of unmonitored spills, leaks, or unexpected liquid/gaseous discharges since May 1, 2021.
- 5. Provide a schedule of expected or planned routine effluent sampling activities (e.g. weekly main vent stack, groundwater sampling, etc.) during the planned onsite inspection week.
- 6. List of permitted gaseous and liquid effluent release points, including release points from on-site surface water bodies (as applicable.)
- 7. Completion documentation of the two most recent surveillances (flow rate, in-place filter testing, and charcoal testing) performed on the:
x Units 1 and 2 Auxiliary Building Filtered Exhaust x
Units 1 and 2 Fuel Building Ventilation
- 8. Material condition surveillance records for effluent treatment system components not readily accessible for any reason (e.g. in-service & spent resin tanks, waste gas hold-up tanks, etc.).
- 9. The two most recent inter-laboratory comparison program results (for the onsite counting lab).
- 10. Most recent audit, self-assessment, and/or review of the radioactive effluent monitoring program
- 11. List of CAP documents generated since May 1, 2021, as a result of gaseous and liquid effluent processing and/or ODCM related activities. This should be a list of documents containing a CAP document number and a brief description, not complete documents.
71124.07 - Radiological Environment Monitoring Program (REMP)
(Last inspected May 2021)
- 1. Procedures for radiological environmental monitoring, including but not limited to:
x Collection, preparation and analysis of environmental samples x
Calibration and maintenance of REMP air and/or water samplers x
Calibration of meteorological monitoring instruments x
Periodic meteorological instrumentation surveillance requirements x
Land use census x
Calibration and quality control of for sample counting instruments
- 2. Procedures associated with the NEI/industry groundwater protection initiative.
- 3. Copy of the 2021, 2022, and 2023 Land Use Census Evaluation or Report.
- 4. Collection schedule for REMP samples to be obtained during the planned inspection week, and contact information for collection staff.
- 5. Last two calibration records for ALL REMP air and water sampling equipment.
Page 4 of 4
- 6. Last two calibration records for meteorological monitoring instrumentation located on the primary tower (wind speed & direction, and air temperature).
- 7. Data recovery report for meteorological monitoring instruments since May 1, 2021.
- 8. List of systems, structures and components identified as credible mechanisms for the potential release of licensed material to the groundwater (e.g. SSC risk ranking matrix)
- 9. List of any non-radioactive system that has become contaminated since May 1, 2021.
- 10. Summary of any leaks and/or spills that have occurred since May 1, 2021 (e.g. copy of 50.75(g) file).
- 11. Copies of any reports to the NRC regarding abnormal onsite spills/leaks or radioactive material since May 1, 2021.
- 12. Groundwater monitoring results since May 1, 2021.
- 13. Environmental TLD results since May 1, 2021.
- 14. List of onsite surface water bodies (e.g. ponds, retention basins, lakes) that contain or can potentially contain radioactivity.
- 15. Most recent audit/self-assessment of REMP activities, including audits of vendor activities.
- 16. List of CAP documents related to REMP activities or groundwater, including leaks or spills since May 1, 2021. This should be a list of documents containing a CAP document number and a brief description, not complete documents.
71151 - Performance Indicator Verification (Public Cornerstones P01)
(Last inspected March 2023)
- 1. Site and corporate procedure(s) for gathering and reporting PI data.
- 2. Copy of the last liquid and gaseous effluent release permit for CY 2023 which specifies the quarterly and annual (year to date) curies released by isotope and the associated public dose assessment(s), or the CY 2023 end-of-year liquid and gaseous effluent release report which specifies the quarterly and annual curies released by isotope and the associated public dose assessment.
- 3. Copy of the most recent gaseous and liquid effluent release permits indicating the current dose to the public (year-to-date doses).
- 4. List of CAP documents related to effluent dose/ODCM issues since April 1, 2023, using keywords such as: RETS, ODCM, effluent, abnormal release, unmonitored release, offsite dose, effluent release, etc. This should be a list of corrective action documents containing a CR number and brief description, not full CRs.
Onsite Assistance During Inspection x
Radiation Protection assistance coordinating walk-downs of the meteorological tower, and gaseous and liquid waste processing systems.
x Radiation Protection / Chemistry coordination for observation of REMP and effluent sampling activities (REMP Run and on-site effluent samples).