L-22-211, Technical Specification 5.6.6 Steam Generator Tube Inspection 180-Day Report
| ML22272A497 | |
| Person / Time | |
|---|---|
| Site: | Davis Besse |
| Issue date: | 09/29/2022 |
| From: | Tony Brown Energy Harbor Nuclear Corp |
| To: | Document Control Desk, Office of Nuclear Reactor Regulation |
| References | |
| L-22-211 | |
| Download: ML22272A497 (90) | |
Text
Terry J. Brown Sife Vice President, Davrs-Besse Nuclear 419-321-7676 September 29,2022 L-22-211 ATTN: Document Control Desk U.S. Nuclear Regulatory Commission Washington, DC 20555-0001
SUBJECT:
Davis-Besse Nuclear Power Station, Unit No. 1 Docket No. 50-346, License No. NPF-3 Technical Specification 5.6.6 Steam Generator Tube lnspection 180-Dav Report Energy Harbor Nuclear Corp., in accordance with the Davis-Besse Nuclear Power Station, Unit 1 (DBNPS) Technical Specification (TS) 5.6.6, "Steam Generator Tube lnspection Report," hereby submits a report of the steam generator tube inspections performed pursuant to TS 5.5.8, "Steam Generator (SG) Program." The attached report summarizes the steam generator tube inspections performed during the DBNPS spring 2022 outage.
There are no regulatory commitments contained in this submittal. lf there are any questions, or if additional information is required, please contact Mr. Phil H. Lashley, Manager - Fleet Licensing, at (330) 696-7208.
S Attachment Davis-Besse Nuclear Power Station Steam Generator Tube lnspection Report cc:
NRC Region lll Administrator NRC Resident Inspector NRR Project Manager Utility Radiological Safety Board J
A energy horbor Energt Harbor Nuclear Corp.
Davis-Besse Nuclear Power Stotion 5501 N. Stote Route 2 Oak Horbor, Ohio 43449
Attachment L-22-211 Davis-Besse Nuclear Power Station Steam Generator Tube Inspection Report Page 1 of 89 Following completion of a steam generator inspection performed in accordance with the Davis-Besse Nuclear Power Station, Unit 1 (DBNPS) Technical Specification (TS) 5.5.8, Steam Generator (SG) Program, TS 5.6.6, Steam Generator Tube Inspection Report, requires a report of the inspection to be submitted to the Nuclear Regulatory Commission within 180 days after the initial entry into MODE 4. This report summarizes the steam generator tube inspection performed during the DBNPS spring 2022 refueling outage (1R22).
The organization of the report is as follows:
Section 1 Scope of Inspections Performed on Each SG (TS 5.6.6.a)
Section 2 Degradation Mechanisms Found (TS 5.6.6.b)
Section 3 Nondestructive Examination Techniques Utilized for Each Degradation Mechanism (TS 5.6.6.c)
Section 4 Location, Orientation (if Linear), and Measured Sizes (if Available) of Service Induced Indications (TS 5.6.6.d)
Section 5 Number of Tubes Plugged During the Inspection Outage for Each Degradation Mechanism (TS 5.6.6.e)
Section 6 The Number and Percentage of Tubes Plugged to Date, and the Effective Plugging Percentage in Each SG (TS 5.6.6.f)
Section 7 The Results of Condition Monitoring, Including the Results of Tube Pulls and In-Situ Testing (TS 5.6.6.g)
The following is a listing of the more common acronyms and abbreviations that are used throughout this report.
1R22 Davis-Besse Unit 1 Spring 2022 Refueling Outage
%TW Percent Through-Wall CMOA Condition Monitoring and Operational Assessment DBNPS Davis-Besse Nuclear Power Station EPRI Electric Power Research Institute ETSS Examination Technique Specification Sheets INCH Location of Indication, in Inches, Relative to TSP Reference PDA Percent Degraded Area Rev.
Revision SG Steam Generator TS Technical Specifications TSP Tube Support Plate xxS Tube Support Plate Number
Attachment L-22-211 Page 2 of 89 Section 1 Scope of Inspections Performed on Each SG (TS 5.6.6.a)
EXAM SCOPE SG 2A SG 1B Eddy Current Full length, bobbin probe [in-service tubes]
15,502 15,538 Special interest, array probe [inspections]
186 145 Visual Previously installed plugs 210 138 Channel head, general 2
2
Attachment L-22-211 Page 3 of 89 Section 2 Degradation Mechanisms Found (TS 5.6.6.b)
Degradation Mechanism SG 2A SG 1B Wear, broached TSP [indications]
2518 869 Wear, drilled TSP [indications]
4 5
Attachment L-22-211 Page 4 of 89 Section 3 Nondestructive Examination Techniques Utilized for Each Degradation Mechanism (TS 5.6.6.c)
The eddy current examinations were performed utilizing various eddy current probes.
All examination techniques utilized were qualified for detection of the relevant degradation mechanisms. This qualification is in accordance with the EPRI SG Examination Guidelines, Revision 8. The applicable Examination Technique Specification Sheets (ETSS) are listed for reference only. Site-specific examination technique sheets are developed prior to each steam generator inspection in accordance with Appendix H or I (as applicable) of the EPRI SG Examination Guidelines, Revision
- 8.
Degradation Mechanism Applicability Probe Type Industry Qualification Wear Broached TSP Bobbin I-96043.4 Rev. 0 Wear Drilled TSP Bobbin I-96042.1 Rev. 4 Wear Broached & Drilled TSP Array I-11956.3 Rev. 3 I-11956.4 Rev. 3
Attachment L-22-211 Page 5 of 89 Section 4 Location, Orientation (if Linear), and Measured Sizes (if Available) of Service Induced Indications (TS 5.6.6.d)
Wear at Broached TSPs SG Row Tube TSP INCH
%TW 2A 1
4 14S
-0.52 14 2A 1
5 14S 0.34 17 2A 1
13 12S
-0.5 7
2A 2
1 16S 0.31 12 2A 2
1 16S
-0.54 21 2A 2
1 14S
-0.56 20 2A 2
2 16S
-0.09 31 2A 2
2 14S 0.5 19 2A 2
2 14S
-0.47 33 2A 2
11 16S 0.35 24 2A 2
12 16S 0.38 15 2A 2
13 16S 0.34 20 2A 2
15 16S
-0.09 31 2A 2
16 16S
-0.12 35 2A 2
19 12S
-0.52 10 2A 2
27 16S
-0.48 19 2A 3
13 16S 0.42 10 2A 3
17 16S 0.43 15 2A 3
18 16S 0.36 13 2A 3
20 16S
-0.09 26 2A 4
2 16S
-0.67 10 2A 4
2 14S
-0.62 11 2A 4
2 16S 0.45 19 2A 4
18 16S 0.35 19 2A 4
20 16S
-0.69 19 2A 5
1 16S
-0.16 31 2A 5
18 15S
-0.56 19 2A 5
19 15S
-0.09 18 2A 5
20 16S 0.37 15 2A 5
21 15S
-0.58 13 2A 5
22 15S 0.42 11 2A 5
23 15S
-0.57 12 2A 6
1 16S
-0.14 37 2A 6
1 14S
-0.52 18 2A 6
2 16S 0.37 19 2A 6
6 16S 0.29 15
Attachment L-22-211 Page 6 of 89 SG Row Tube TSP INCH
%TW 2A 6
15 15S 0.46 17 2A 6
16 15S
-0.54 17 2A 6
17 15S
-0.54 14 2A 6
19 15S 0.42 19 2A 6
20 15S 0.37 17 2A 6
22 15S 0.46 13 2A 6
23 15S
-0.61 15 2A 6
24 16S 0.35 11 2A 7
1 16S
-0.14 39 2A 7
13 15S
-0.07 19 2A 7
14 15S
-0.63 11 2A 7
15 15S
-0.56 13 2A 7
16 15S
-0.07 19 2A 7
17 15S
-0.58 12 2A 7
18 15S
-0.61 19 2A 7
19 15S
-0.61 17 2A 7
20 15S 0.33 12 2A 7
21 15S
-0.56 10 2A 7
22 15S 0.53 10 2A 7
22 15S
-0.63 15 2A 7
23 16S
-0.19 27 2A 7
25 15S
-0.54 17 2A 7
27 15S 0.39 20 2A 8
14 16S 0.47 16 2A 8
14 15S 0.42 13 2A 8
14 15S
-0.54 18 2A 8
17 15S 0.4 11 2A 8
18 15S
-0.61 14 2A 8
20 15S
-0.54 14 2A 8
22 15S 0.51 10 2A 8
23 15S 0.3 22 2A 8
24 15S 0.37 17 2A 8
26 15S
-0.63 11 2A 8
27 15S 0.53 13 2A 8
32 15S 0.32 12 2A 8
35 15S 0.46 12 2A 9
1 16S
-0.21 43 2A 9
1 14S
-0.57 12 2A 9
2 14S
-0.57 12 2A 9
11 15S 0.44 14 2A 9
15 15S 0.35 14 2A 9
16 15S
-0.61 16
Attachment L-22-211 Page 7 of 89 SG Row Tube TSP INCH
%TW 2A 9
19 15S
-0.58 9
2A 9
23 16S 0.4 11 2A 9
24 15S 0.51 13 2A 9
26 15S 0.28 16 2A 9
27 16S
-0.14 16 2A 10 3
16S 0.27 17 2A 10 10 15S 0.46 19 2A 10 11 16S 0.38 15 2A 10 11 15S 0.42 16 2A 10 11 14S
-0.57 10 2A 10 16 15S
-0.63 19 2A 10 17 15S
-0.61 11 2A 10 18 15S 0.4 18 2A 10 22 15S
-0.61 19 2A 10 48 16S
-0.71 12 2A 10 49 15S 0.52 9
2A 10 55 16S 0.22 11 2A 11 1
16S
-0.16 36 2A 11 1
14S
-0.57 24 2A 11 10 15S 0.47 15 2A 11 11 15S
-0.59 19 2A 11 13 16S 0.27 16 2A 11 27 15S 0.47 11 2A 11 38 15S 0.51 12 2A 11 67 16S
-0.14 20 2A 12 1
16S 0
30 2A 12 2
14S
-0.55 13 2A 12 6
16S 0.31 17 2A 12 10 15S
-0.54 22 2A 12 11 15S 0.46 10 2A 12 11 15S
-0.57 14 2A 12 13 16S 0.24 16 2A 12 14 15S
-0.56 17 2A 12 23 15S
-0.11 19 2A 13 9
15S
-0.59 12 2A 13 11 15S
-0.56 11 2A 13 12 15S 0.42 19 2A 13 12 14S
-0.57 10 2A 13 13 15S 0.43 15 2A 13 16 15S 0.42 20 2A 13 23 15S
-0.68 19 2A 13 47 15S 0.52 11
Attachment L-22-211 Page 8 of 89 SG Row Tube TSP INCH
%TW 2A 13 73 16S
-0.79 11 2A 14 1
14S
-0.57 15 2A 14 2
14S
-0.57 14 2A 14 6
16S 0
21 2A 14 8
15S 0.44 16 2A 14 9
15S
-0.59 21 2A 14 11 15S
-0.61 11 2A 14 12 15S 0.46 13 2A 14 13 16S 0
18 2A 14 41 15S 0.47 16 2A 14 75 16S 0
17 2A 15 1
14S
-0.57 17 2A 15 1
16S 0
30 2A 15 2
14S
-0.54 13 2A 15 8
15S
-0.57 21 2A 15 9
15S 0.44 14 2A 15 10 15S
-0.59 10 2A 15 11 15S 0.37 16 2A 15 15 16S 0.38 11 2A 15 25 15S 0.48 19 2A 15 53 15S
-0.57 12 2A 15 53 14S
-0.56 12 2A 15 57 15S
-0.6 10 2A 15 63 15S
-0.61 16 2A 16 1
16S
-0.11 31 2A 16 1
14S
-0.53 14 2A 16 8
16S
-0.62 13 2A 16 8
16S 0.37 11 2A 16 8
15S 0
25 2A 16 9
15S 0.48 17 2A 16 10 15S
-0.57 14 2A 16 11 15S 0.39 15 2A 16 12 16S
-0.57 17 2A 16 12 15S 0.3 21 2A 16 13 15S 0.46 10 2A 16 14 16S 0.33 17 2A 16 23 15S 0.3 19 2A 17 7
15S 0
24 2A 17 8
15S 0
23 2A 17 9
15S 0.46 13 2A 17 10 15S 0.45 15 2A 17 11 15S 0.46 19
Attachment L-22-211 Page 9 of 89 SG Row Tube TSP INCH
%TW 2A 17 12 15S
-0.59 15 2A 17 13 15S 0.48 12 2A 17 23 15S
-0.54 24 2A 17 32 13S 0
18 2A 17 50 15S 0
16 2A 17 52 15S
-0.6 17 2A 17 82 16S
-0.13 26 2A 18 1
16S
-0.11 31 2A 18 1
14S
-0.55 13 2A 18 8
16S
-0.59 9
2A 18 8
15S 0.48 15 2A 18 9
16S 0.33 13 2A 18 9
16S
-0.67 15 2A 18 9
15S 0.49 11 2A 18 9
15S
-0.57 21 2A 18 10 15S
-0.57 14 2A 18 11 15S
-0.57 12 2A 18 12 15S
-0.59 14 2A 18 13 16S
-0.63 18 2A 18 13 15S
-0.59 15 2A 18 16 15S
-0.57 11 2A 18 22 16S
-0.75 12 2A 18 25 15S 0.46 12 2A 18 54 15S 0.42 12 2A 19 7
15S
-0.61 12 2A 19 8
15S 0
18 2A 19 9
15S 0.44 14 2A 19 10 15S 0.44 15 2A 19 12 15S
-0.57 20 2A 19 13 15S
-0.64 10 2A 19 15 15S 0.42 11 2A 19 17 15S
-0.59 11 2A 19 57 15S 0
20 2A 19 59 15S
-0.62 12 2A 19 61 15S 0
18 2A 19 65 15S 0.52 14 2A 19 86 16S
-0.18 33 2A 20 1
16S 0.33 16 2A 20 1
16S
-0.55 24 2A 20 7
15S 0.48 13 2A 20 7
15S
-0.61 14 2A 20 9
15S
-0.59 20
Attachment L-22-211 Page 10 of 89 SG Row Tube TSP INCH
%TW 2A 20 10 15S
-0.59 16 2A 20 11 15S
-0.59 16 2A 20 13 15S 0.42 15 2A 20 16 16S
-0.62 11 2A 20 61 15S 0.5 12 2A 20 61 15S
-0.61 11 2A 20 65 15S 0
29 2A 20 76 15S
-0.62 11 2A 20 76 14S
-0.46 12 2A 21 8
15S
-0.61 16 2A 21 10 15S 0.44 14 2A 21 10 15S
-0.57 14 2A 21 11 15S 0.5 13 2A 21 12 15S
-0.59 13 2A 21 13 15S 0.39 25 2A 21 56 15S
-0.52 13 2A 21 62 14S
-0.62 13 2A 21 89 16S
-0.16 19 2A 21 90 16S
-0.13 22 2A 22 1
16S
-0.11 39 2A 22 1
14S
-0.57 13 2A 22 7
15S 0.48 15 2A 22 7
15S
-0.63 12 2A 22 8
15S 0.46 18 2A 22 9
15S
-0.61 19 2A 22 11 15S 0.43 19 2A 22 16 16S
-0.7 13 2A 22 56 15S 0
17 2A 22 62 15S 0.41 11 2A 22 66 15S
-0.53 13 2A 23 3
16S 0.27 14 2A 23 7
15S
-0.59 17 2A 23 8
15S 0
18 2A 23 9
15S
-0.59 12 2A 23 10 15S
-0.63 11 2A 23 12 15S
-0.57 14 2A 23 36 16S
-0.72 8
2A 23 57 15S
-0.54 13 2A 23 64 15S 0.45 12 2A 23 66 15S
-0.48 15 2A 23 69 15S
-0.65 12 2A 23 81 16S
-0.73 13
Attachment L-22-211 Page 11 of 89 SG Row Tube TSP INCH
%TW 2A 24 7
15S
-0.57 17 2A 24 10 15S 0.49 16 2A 24 13 16S
-0.63 14 2A 24 16 15S 0.46 10 2A 24 16 15S
-0.57 12 2A 24 18 16S
-0.7 8
2A 24 48 15S
-0.55 11 2A 24 57 15S 0.4 16 2A 24 57 15S
-0.57 15 2A 24 95 16S
-0.11 22 2A 25 1
16S 0.33 20 2A 25 7
15S 0.46 22 2A 25 7
15S
-0.59 9
2A 25 9
15S 0.41 15 2A 25 26 15S 0
21 2A 25 36 16S 0.33 11 2A 25 50 15S 0.44 15 2A 25 50 15S
-0.52 11 2A 25 65 15S 0
11 2A 25 66 15S 0
20 2A 25 83 16S
-0.78 21 2A 26 6
15S
-0.61 11 2A 26 9
15S
-0.59 9
2A 26 10 15S 0.49 12 2A 26 10 15S
-0.59 16 2A 26 18 16S
-0.67 11 2A 26 35 16S
-0.79 13 2A 26 58 15S
-0.54 18 2A 26 67 14S
-0.57 7
2A 26 72 15S 0
17 2A 26 89 15S 0.45 18 2A 26 99 16S
-0.16 35 2A 27 6
15S 0.46 23 2A 27 8
15S
-0.59 15 2A 27 11 15S 0.44 20 2A 27 11 15S
-0.64 10 2A 27 12 15S 0.46 22 2A 27 13 15S
-0.55 9
2A 27 15 15S
-0.61 15 2A 27 19 16S
-0.14 19 2A 27 63 15S 0.35 16 2A 27 66 15S 0
15
Attachment L-22-211 Page 12 of 89 SG Row Tube TSP INCH
%TW 2A 27 67 15S 0.49 12 2A 27 68 15S
-0.48 13 2A 27 71 15S 0
14 2A 27 73 15S 0
24 2A 27 74 15S 0
15 2A 27 100 16S
-0.18 37 2A 28 8
15S
-0.57 15 2A 28 11 15S 0.5 12 2A 28 58 15S
-0.55 12 2A 28 69 15S 0
11 2A 28 70 15S 0.4 13 2A 28 72 15S 0.35 16 2A 28 72 15S
-0.55 11 2A 28 74 15S 0.4 11 2A 29 1
16S
-0.11 31 2A 29 6
15S
-0.57 16 2A 29 7
15S
-0.57 11 2A 29 8
15S 0.43 21 2A 29 10 14S
-0.57 13 2A 29 57 15S
-0.52 12 2A 29 64 15S
-0.53 12 2A 29 65 15S 0
16 2A 29 88 15S 0.45 17 2A 29 92 15S
-0.07 16 2A 30 7
15S 0.39 16 2A 30 7
15S
-0.59 14 2A 30 10 15S
-0.62 13 2A 30 14 16S 0.35 9
2A 30 14 16S
-0.6 12 2A 30 17 15S 0.49 13 2A 30 53 15S
-0.53 13 2A 30 83 15S
-0.57 17 2A 30 105 16S
-0.18 40 2A 31 6
15S 0.54 12 2A 31 6
15S
-0.56 19 2A 31 7
15S 0.32 17 2A 31 9
15S 0
16 2A 31 10 15S 0.48 15 2A 31 17 15S
-0.54 12 2A 31 19 15S
-0.05 20 2A 31 58 15S 0.46 11 2A 31 58 15S
-0.59 10
Attachment L-22-211 Page 13 of 89 SG Row Tube TSP INCH
%TW 2A 31 61 15S
-0.51 15 2A 31 63 15S
-0.6 8
2A 31 64 15S
-0.55 14 2A 31 77 15S 0
17 2A 31 93 15S
-0.57 21 2A 31 106 16S
-0.15 37 2A 32 6
15S
-0.56 14 2A 32 11 15S 0.43 16 2A 32 20 16S 0
18 2A 32 34 15S
-0.55 11 2A 32 39 15S
-0.09 18 2A 32 39 14S
-0.57 9
2A 32 81 15S 0
13 2A 32 87 15S 0.45 13 2A 32 91 15S 0.43 12 2A 32 94 16S
-0.59 14 2A 32 105 16S
-0.81 13 2A 32 107 16S
-0.13 28 2A 33 5
15S
-0.59 11 2A 33 7
15S
-0.64 14 2A 33 8
15S
-0.59 12 2A 33 10 15S 0.41 18 2A 33 12 15S 0.44 15 2A 33 14 16S 0.35 11 2A 33 14 16S
-0.6 11 2A 33 59 15S 0.44 9
2A 33 63 15S 0
14 2A 33 77 15S 0
15 2A 33 78 15S 0.4 11 2A 33 81 15S 0
13 2A 33 89 15S 0.41 15 2A 33 95 15S
-0.11 23 2A 33 99 16S
-0.11 19 2A 33 105 16S
-0.12 27 2A 33 106 16S
-0.61 13 2A 33 108 16S 0.37 13 2A 34 5
15S 0.48 16 2A 34 6
15S 0.44 13 2A 34 7
16S
-0.57 17 2A 34 10 15S 0.51 12 2A 34 58 15S
-0.55 9
2A 34 61 15S
-0.53 9
Attachment L-22-211 Page 14 of 89 SG Row Tube TSP INCH
%TW 2A 34 69 15S 0.38 9
2A 34 88 15S 0.45 12 2A 34 88 15S
-0.57 15 2A 34 89 15S
-0.53 17 2A 35 7
15S
-0.58 19 2A 35 8
16S
-0.57 10 2A 35 8
15S
-0.59 15 2A 35 11 15S
-0.57 17 2A 35 29 16S
-0.72 11 2A 35 57 15S 0.42 12 2A 35 66 15S 0
12 2A 35 70 15S
-0.53 13 2A 35 75 15S
-0.53 15 2A 35 79 16S
-0.79 11 2A 35 86 15S
-0.6 18 2A 35 89 15S 0.43 20 2A 35 89 15S
-0.55 19 2A 35 103 16S
-0.55 12 2A 35 106 16S
-0.54 12 2A 35 110 16S
-0.11 12 2A 36 1
16S 0
28 2A 36 11 15S
-0.58 16 2A 36 55 13S
-0.52 13 2A 36 58 15S 0.52 18 2A 36 58 15S
-0.68 12 2A 36 71 15S 0.37 16 2A 36 73 15S 0
12 2A 36 82 15S
-0.48 11 2A 36 85 16S
-0.79 10 2A 36 99 16S
-0.14 17 2A 36 105 16S
-0.59 8
2A 36 108 16S
-0.62 15 2A 37 1
16S
-0.09 21 2A 37 1
14S 0
18 2A 37 8
15S
-0.59 8
2A 37 10 15S
-0.61 10 2A 37 11 15S
-0.64 8
2A 37 70 15S
-0.69 12 2A 37 73 15S
-0.54 11 2A 37 78 15S
-0.13 21 2A 37 83 15S 0.38 15 2A 37 83 15S
-0.54 20
Attachment L-22-211 Page 15 of 89 SG Row Tube TSP INCH
%TW 2A 37 93 15S
-0.45 13 2A 37 94 15S
-0.55 15 2A 37 96 15S 0.41 16 2A 37 96 15S
-0.57 16 2A 37 106 16S
-0.7 13 2A 37 107 16S
-0.64 12 2A 38 2
16S
-0.62 13 2A 38 3
16S
-0.6 10 2A 38 7
15S
-0.61 13 2A 38 10 15S
-0.57 19 2A 38 12 15S 0.5 11 2A 38 19 16S
-0.6 14 2A 38 39 16S 0.53 14 2A 38 92 15S
-0.66 12 2A 38 93 15S
-0.54 15 2A 38 95 16S
-0.61 14 2A 38 105 16S
-0.63 15 2A 39 1
16S
-0.09 23 2A 39 10 15S
-0.62 11 2A 39 24 16S
-0.71 15 2A 39 33 15S 0.41 17 2A 39 59 15S
-0.57 10 2A 39 64 15S
-0.55 13 2A 39 81 15S
-0.59 10 2A 39 87 15S 0.36 9
2A 39 93 15S 0.48 18 2A 39 97 15S
-0.57 15 2A 39 100 15S
-0.07 19 2A 39 107 16S
-0.63 12 2A 39 109 16S 0.36 13 2A 39 112 16S
-0.14 30 2A 39 116 16S
-0.64 18 2A 40 8
15S 0.48 14 2A 40 9
15S
-0.61 10 2A 40 10 15S 0.46 19 2A 40 11 15S
-0.57 12 2A 40 61 15S
-0.55 11 2A 40 87 15S
-0.57 20 2A 40 94 15S 0.53 13 2A 40 99 15S 0
28 2A 40 107 16S
-0.68 11 2A 41 4
15S 0.48 20
Attachment L-22-211 Page 16 of 89 SG Row Tube TSP INCH
%TW 2A 41 8
15S
-0.59 11 2A 41 10 15S 0.46 13 2A 41 24 16S
-0.55 12 2A 41 92 15S
-0.68 10 2A 41 96 15S 0.46 18 2A 41 97 15S 0.46 11 2A 41 99 15S 0.42 16 2A 41 100 15S
-0.52 16 2A 41 101 15S 0.43 12 2A 41 105 15S 0.36 13 2A 41 105 15S
-0.57 13 2A 41 106 16S
-0.65 10 2A 41 107 16S
-0.7 10 2A 41 113 16S
-0.18 37 2A 41 115 16S
-0.66 18 2A 42 4
16S
-0.69 16 2A 42 4
15S
-0.61 12 2A 42 4
14S
-0.52 9
2A 42 5
16S
-0.58 11 2A 42 91 15S
-0.54 11 2A 42 99 15S
-0.13 16 2A 42 100 15S 0.41 22 2A 42 106 16S
-0.67 11 2A 42 108 16S
-0.68 14 2A 42 113 16S
-0.68 14 2A 42 113 15S
-0.07 13 2A 42 115 16S
-0.72 13 2A 42 116 16S
-0.73 16 2A 43 4
15S 0
24 2A 43 27 16S
-0.75 15 2A 43 31 16S
-0.63 17 2A 43 82 15S
-0.63 11 2A 43 86 15S 0.45 11 2A 43 105 15S 0.39 10 2A 43 113 16S
-0.72 13 2A 43 118 11S 0.41 15 2A 44 4
15S 0
19 2A 44 5
16S
-0.55 13 2A 44 5
15S 0.51 9
2A 44 5
15S
-0.6 23 2A 44 7
15S 0
19 2A 44 9
16S
-0.57 12
Attachment L-22-211 Page 17 of 89 SG Row Tube TSP INCH
%TW 2A 44 13 15S 0.51 9
2A 44 14 15S
-0.64 17 2A 44 18 16S
-0.58 12 2A 44 21 16S
-0.6 10 2A 44 74 15S 0.45 14 2A 44 74 15S
-0.59 12 2A 44 85 15S 0.43 14 2A 44 88 15S
-0.61 11 2A 44 91 15S 0.43 14 2A 44 94 16S
-0.64 12 2A 44 99 15S 0.4 15 2A 44 100 16S
-0.72 12 2A 44 100 15S 0.36 12 2A 44 102 15S 0.39 13 2A 44 102 15S
-0.54 15 2A 44 103 16S
-0.72 14 2A 44 110 15S 0.36 14 2A 44 119 16S
-0.11 31 2A 44 119 11S 0.5 14 2A 45 7
15S
-0.64 10 2A 45 12 15S
-0.59 16 2A 45 16 15S
-0.63 13 2A 45 29 16S
-0.55 13 2A 45 81 15S
-0.63 12 2A 45 91 15S
-0.14 14 2A 45 98 15S
-0.54 13 2A 45 99 15S 0.48 16 2A 45 102 15S
-0.07 19 2A 45 105 16S
-0.72 15 2A 45 105 15S
-0.05 17 2A 45 115 15S 0.36 12 2A 45 117 16S
-0.11 25 2A 45 118 16S
-0.68 13 2A 45 119 16S
-0.67 16 2A 45 120 16S
-0.14 39 2A 46 1
14S
-0.59 6
2A 46 5
15S 0.49 19 2A 46 6
15S
-0.55 16 2A 46 8
15S
-0.6 11 2A 46 13 16S
-0.52 8
2A 46 22 16S
-0.6 13 2A 46 26 16S
-0.54 15
Attachment L-22-211 Page 18 of 89 SG Row Tube TSP INCH
%TW 2A 46 79 15S
-0.63 12 2A 46 85 15S
-0.59 9
2A 46 91 15S
-0.59 13 2A 46 99 15S
-0.09 19 2A 46 101 15S
-0.05 24 2A 46 102 15S 0.34 19 2A 46 103 15S
-0.09 24 2A 46 105 16S
-0.71 16 2A 46 105 15S
-0.09 21 2A 46 108 16S
-0.67 17 2A 46 111 15S
-0.07 18 2A 46 117 16S
-0.68 14 2A 46 121 16S
-0.7 11 2A 47 5
15S
-0.5 9
2A 47 6
14S
-0.55 11 2A 47 6
15S 0
16 2A 47 10 15S 0.4 16 2A 47 11 15S
-0.63 10 2A 47 17 15S
-0.64 10 2A 47 24 16S
-0.55 10 2A 47 28 16S 0.51 12 2A 47 60 13S
-0.57 9
2A 47 89 15S
-0.61 8
2A 47 95 15S 0.36 22 2A 47 121 16S
-0.14 24 2A 47 122 16S
-0.13 23 2A 48 5
15S 0
19 2A 48 6
15S
-0.59 16 2A 48 7
15S 0.46 14 2A 48 10 16S
-0.58 12 2A 48 11 16S
-0.55 10 2A 48 12 16S
-0.57 12 2A 48 20 15S 0
26 2A 48 27 16S
-0.63 10 2A 48 33 16S
-0.19 14 2A 48 36 16S
-0.72 14 2A 48 48 16S 0.53 9
2A 48 103 15S 0.43 12 2A 48 104 16S
-0.63 13 2A 48 107 16S
-0.65 15 2A 48 107 15S
-0.14 16 2A 48 108 16S
-0.63 15
Attachment L-22-211 Page 19 of 89 SG Row Tube TSP INCH
%TW 2A 48 120 16S
-0.72 14 2A 48 122 16S
-0.68 18 2A 48 123 16S
-0.13 29 2A 49 6
15S 0.45 12 2A 49 6
15S
-0.59 10 2A 49 7
16S
-0.53 12 2A 49 8
15S 0
18 2A 49 9
15S
-0.59 8
2A 49 10 16S
-0.58 11 2A 49 28 16S
-0.57 10 2A 49 32 16S
-0.82 13 2A 49 95 15S 0.41 18 2A 49 103 15S 0.41 15 2A 49 103 15S
-0.54 12 2A 49 107 16S
-0.67 13 2A 49 109 15S 0.38 18 2A 50 4
15S
-0.59 22 2A 50 5
15S
-0.55 13 2A 50 6
15S
-0.59 21 2A 50 10 16S 0.33 11 2A 50 94 15S 0.41 13 2A 50 96 15S
-0.6 12 2A 50 98 16S
-0.61 8
2A 50 101 15S 0.43 13 2A 50 107 15S
-0.58 10 2A 50 118 16S
-0.64 18 2A 51 4
15S
-0.62 19 2A 51 5
16S
-0.53 14 2A 51 5
15S
-0.6 18 2A 51 6
15S 0
16 2A 51 8
15S 0.51 11 2A 51 29 16S
-0.77 14 2A 51 33 16S
-0.7 14 2A 51 35 16S 0.47 16 2A 51 89 15S 0.43 11 2A 51 109 16S
-0.16 21 2A 51 109 15S
-0.07 29 2A 51 124 16S
-0.14 29 2A 52 4
15S 0.51 15 2A 52 4
15S
-0.62 11 2A 52 5
15S 0.49 15 2A 52 6
15S
-0.59 13
Attachment L-22-211 Page 20 of 89 SG Row Tube TSP INCH
%TW 2A 52 7
15S 0
19 2A 52 10 16S
-0.63 11 2A 52 10 15S
-0.07 20 2A 52 11 16S 0.34 11 2A 52 11 15S 0.42 20 2A 52 24 16S
-0.55 10 2A 52 80 15S 0.46 12 2A 52 124 16S
-0.11 20 2A 52 125 16S
-0.16 41 2A 53 1
16S 0
23 2A 53 5
15S
-0.57 16 2A 53 6
15S
-0.59 14 2A 53 7
15S 0.49 16 2A 53 8
16S
-0.6 8
2A 53 10 16S
-0.56 13 2A 53 10 15S
-0.59 15 2A 53 11 15S
-0.59 14 2A 53 12 16S
-0.57 14 2A 53 101 15S 0.41 15 2A 53 102 15S
-0.61 15 2A 53 110 15S 0.45 13 2A 53 110 15S
-0.57 17 2A 53 112 15S
-0.07 24 2A 53 113 15S 0.36 16 2A 53 113 15S
-0.52 12 2A 53 117 15S 0.34 13 2A 53 117 15S
-0.59 9
2A 53 121 16S
-0.14 28 2A 53 123 16S
-0.68 15 2A 53 125 16S
-0.14 30 2A 53 126 16S
-0.14 37 2A 54 1
16S
-0.09 33 2A 54 4
16S
-0.53 16 2A 54 5
15S 0
19 2A 54 7
16S
-0.58 11 2A 54 10 15S 0
16 2A 54 12 15S 0
19 2A 54 38 16S
-0.65 11 2A 54 81 15S
-0.65 13 2A 54 88 16S
-0.71 12 2A 54 113 15S
-0.59 12 2A 54 120 16S
-0.64 9
Attachment L-22-211 Page 21 of 89 SG Row Tube TSP INCH
%TW 2A 54 122 16S 0.3 13 2A 54 125 16S
-0.68 16 2A 54 126 16S
-0.18 40 2A 54 127 16S
-0.14 35 2A 55 4
15S
-0.64 12 2A 55 6
15S
-0.59 14 2A 55 7
15S 0.44 18 2A 55 9
16S
-0.69 14 2A 55 40 16S
-0.67 12 2A 55 63 16S
-0.72 12 2A 55 95 15S
-0.61 10 2A 55 100 15S 0.43 11 2A 55 105 15S
-0.59 10 2A 55 106 16S
-0.66 12 2A 55 107 15S
-0.05 14 2A 55 108 15S
-0.61 9
2A 55 111 15S
-0.59 14 2A 55 112 16S
-0.14 14 2A 55 118 15S
-0.61 9
2A 55 124 16S
-0.7 16 2A 55 125 16S
-0.14 32 2A 55 126 16S
-0.11 29 2A 56 1
16S
-0.71 13 2A 56 5
16S
-0.63 12 2A 56 5
15S 0
18 2A 56 8
15S 0.44 14 2A 56 25 15S
-0.6 16 2A 56 28 13S
-0.55 11 2A 56 114 15S
-0.54 15 2A 56 120 16S
-0.61 18 2A 56 122 15S
-0.59 10 2A 56 125 16S
-0.02 17 2A 56 126 16S
-0.64 12 2A 57 6
15S
-0.57 16 2A 57 7
15S
-0.57 19 2A 57 8
15S 0.41 20 2A 57 9
15S
-0.62 12 2A 57 11 16S
-0.69 11 2A 57 12 15S 0.46 17 2A 57 13 15S
-0.57 11 2A 57 39 16S
-0.61 11 2A 57 45 16S 0.38 9
Attachment L-22-211 Page 22 of 89 SG Row Tube TSP INCH
%TW 2A 57 49 13S
-0.56 8
2A 57 125 16S
-0.61 16 2A 57 126 16S
-0.16 26 2A 57 127 16S
-0.64 17 2A 57 128 16S
-0.14 38 2A 58 1
16S
-0.12 31 2A 58 4
15S 0.51 18 2A 58 5
16S
-0.65 17 2A 58 5
15S
-0.64 17 2A 58 6
15S 0.46 20 2A 58 7
15S
-0.59 18 2A 58 12 16S 0.31 13 2A 58 13 15S 0
15 2A 58 16 15S 0.43 15 2A 58 55 16S
-0.8 12 2A 58 97 15S
-0.57 9
2A 58 111 15S
-0.02 20 2A 58 112 15S
-0.57 18 2A 58 120 15S 0.02 16 2A 58 122 16S
-0.11 18 2A 58 124 16S
-0.7 13 2A 58 126 16S
-0.64 15 2A 58 127 16S
-0.11 24 2A 58 129 16S
-0.11 37 2A 59 5
15S
-0.5 13 2A 59 9
15S 0
15 2A 59 10 15S 0.49 19 2A 59 23 16S
-0.64 10 2A 59 90 15S
-0.59 20 2A 59 102 16S
-0.66 11 2A 59 108 15S
-0.57 10 2A 59 114 15S
-0.61 11 2A 59 126 16S
-0.11 25 2A 59 127 16S
-0.61 16 2A 60 1
16S
-0.62 13 2A 60 4
15S 0.46 22 2A 60 5
15S 0
18 2A 60 7
15S
-0.57 14 2A 60 10 15S
-0.07 21 2A 60 10 16S
-0.71 16 2A 60 12 15S 0
19 2A 60 13 15S
-0.57 12
Attachment L-22-211 Page 23 of 89 SG Row Tube TSP INCH
%TW 2A 60 14 16S
-0.68 12 2A 60 45 16S
-0.83 11 2A 60 93 15S
-0.59 10 2A 60 104 15S
-0.09 18 2A 60 111 15S
-0.11 23 2A 60 112 15S 0.41 19 2A 60 112 15S
-0.59 23 2A 60 127 16S
-0.64 9
2A 60 128 16S
-0.11 16 2A 60 129 16S
-0.09 26 2A 61 1
16S
-0.09 31 2A 61 6
16S
-0.71 10 2A 61 6
15S
-0.59 13 2A 61 41 16S
-0.73 10 2A 61 96 15S 0.39 11 2A 61 96 15S
-0.59 13 2A 61 106 16S
-0.66 15 2A 61 108 15S
-0.59 19 2A 61 110 15S
-0.07 16 2A 61 114 15S
-0.61 13 2A 61 121 15S
-0.61 12 2A 61 129 16S
-0.11 25 2A 62 3
16S
-0.63 16 2A 62 3
15S
-0.64 23 2A 62 5
16S
-0.75 13 2A 62 5
15S
-0.62 14 2A 62 12 13S
-0.57 8
2A 62 12 15S 0
20 2A 62 13 16S
-0.6 13 2A 62 20 16S
-0.65 11 2A 62 100 15S
-0.59 11 2A 62 110 15S
-0.59 16 2A 62 116 15S
-0.07 22 2A 62 119 15S
-0.11 20 2A 62 125 16S
-0.14 25 2A 62 127 16S
-0.62 14 2A 62 128 16S
-0.11 25 2A 62 129 16S
-0.11 20 2A 63 1
16S 0.38 19 2A 63 1
16S
-0.71 8
2A 63 2
16S
-0.69 23 2A 63 3
16S 0.27 11
Attachment L-22-211 Page 24 of 89 SG Row Tube TSP INCH
%TW 2A 63 3
16S
-0.55 12 2A 63 4
15S
-0.59 29 2A 63 4
16S
-0.05 15 2A 63 5
15S 0.53 15 2A 63 5
15S
-0.64 12 2A 63 8
16S
-0.61 22 2A 63 8
15S
-0.56 20 2A 63 16 16S
-0.57 11 2A 63 33 13S
-0.57 8
2A 63 43 16S
-0.68 13 2A 63 44 16S 0.34 11 2A 63 113 15S
-0.09 16 2A 63 115 15S
-0.61 16 2A 63 119 15S
-0.09 18 2A 63 120 16S 0.41 13 2A 63 120 16S
-0.7 17 2A 63 120 15S 0.43 14 2A 63 120 15S
-0.59 16 2A 63 121 15S
-0.59 14 2A 63 122 16S
-0.11 25 2A 63 125 16S
-0.16 30 2A 63 127 16S
-0.64 11 2A 63 128 16S
-0.11 20 2A 63 129 16S
-0.11 23 2A 63 130 16S
-0.09 27 2A 64 1
16S
-0.11 25 2A 64 2
16S 0.45 12 2A 64 2
16S
-0.73 16 2A 64 3
16S 0.4 14 2A 64 4
16S 0.4 15 2A 64 4
16S
-0.6 12 2A 64 4
15S
-0.64 21 2A 64 8
15S 0.51 11 2A 64 11 15S
-0.61 11 2A 64 13 16S
-0.7 15 2A 64 13 15S
-0.55 21 2A 64 44 16S
-0.72 11 2A 64 111 15S
-0.61 15 2A 64 113 15S
-0.59 14 2A 64 114 15S 0.34 16 2A 64 128 16S
-0.11 29 2A 64 129 16S
-0.11 19
Attachment L-22-211 Page 25 of 89 SG Row Tube TSP INCH
%TW 2A 64 130 16S
-0.11 19 2A 65 3
15S
-0.57 19 2A 65 4
16S 0.4 18 2A 65 4
16S
-0.65 12 2A 65 4
15S
-0.62 17 2A 65 6
15S 0.48 17 2A 65 6
15S
-0.59 8
2A 65 7
15S
-0.59 11 2A 65 8
16S
-0.61 13 2A 65 9
15S 0.52 12 2A 65 9
15S
-0.59 13 2A 65 10 15S 0.46 14 2A 65 11 15S 0
21 2A 65 12 16S
-0.6 13 2A 65 13 16S 0
14 2A 65 36 16S 0.36 10 2A 65 45 16S
-0.74 15 2A 65 55 16S
-0.78 10 2A 65 107 15S
-0.18 13 2A 65 108 15S 0.32 18 2A 65 108 15S
-0.59 21 2A 65 111 15S
-0.11 20 2A 65 113 15S 0.41 16 2A 65 114 15S 0.34 20 2A 65 114 15S
-0.59 23 2A 65 115 16S
-0.68 13 2A 65 115 15S
-0.59 13 2A 65 121 16S 0.43 12 2A 65 121 16S
-0.68 17 2A 65 124 16S
-0.11 20 2A 65 128 16S
-0.57 14 2A 65 129 16S
-0.09 26 2A 65 130 16S
-0.11 31 2A 65 130 13S 0.48 14 2A 66 1
16S
-0.14 39 2A 66 4
15S 0.49 22 2A 66 4
15S
-0.64 10 2A 66 6
15S
-0.57 14 2A 66 10 16S
-0.57 16 2A 66 11 15S 0.51 17 2A 66 32 13S
-0.52 10 2A 66 39 13S
-0.61 7
Attachment L-22-211 Page 26 of 89 SG Row Tube TSP INCH
%TW 2A 66 46 16S 0.4 13 2A 66 46 16S
-0.78 9
2A 66 110 15S
-0.61 11 2A 66 112 15S 0.43 15 2A 66 114 15S 0.39 13 2A 66 121 16S
-0.11 16 2A 66 124 16S
-0.09 22 2A 66 127 16S
-0.09 25 2A 66 129 16S
-0.11 19 2A 66 130 16S
-0.11 25 2A 66 130 11S 0.55 23 2A 66 131 16S
-0.11 41 2A 66 131 13S
-0.43 11 2A 67 4
15S 0.56 18 2A 67 6
15S
-0.57 10 2A 67 8
16S
-0.55 15 2A 67 8
15S
-0.61 18 2A 67 11 16S
-0.52 15 2A 67 12 16S
-0.11 21 2A 67 20 16S
-0.69 14 2A 67 22 16S
-0.6 13 2A 67 37 16S 0.43 13 2A 67 44 16S 0.41 11 2A 67 94 15S
-0.81 9
2A 67 109 16S
-0.63 13 2A 67 109 15S 0.41 14 2A 67 119 15S
-0.61 21 2A 67 123 16S
-0.11 27 2A 67 127 16S 0.3 14 2A 67 128 16S
-0.11 16 2A 67 129 16S
-0.11 37 2A 67 130 16S
-0.05 23 2A 68 1
14S
-0.55 7
2A 68 1
16S 0
17 2A 68 4
16S 0
18 2A 68 4
15S 0
23 2A 68 5
15S 0
18 2A 68 6
16S 0.36 16 2A 68 6
15S
-0.56 12 2A 68 8
16S
-0.68 16 2A 68 9
15S
-0.59 13 2A 68 10 16S
-0.6 14
Attachment L-22-211 Page 27 of 89 SG Row Tube TSP INCH
%TW 2A 68 15 16S
-0.66 12 2A 68 19 16S
-0.55 11 2A 68 23 16S
-0.72 19 2A 68 24 16S
-0.77 13 2A 68 25 16S
-0.69 13 2A 68 45 16S 0.36 13 2A 68 46 16S
-0.67 13 2A 68 106 15S
-0.61 11 2A 68 109 15S 0.45 16 2A 68 113 15S
-0.61 9
2A 68 113 15S 0.41 19 2A 68 126 16S
-0.65 17 2A 68 128 16S
-0.11 19 2A 68 129 16S
-0.61 10 2A 68 130 16S
-0.11 33 2A 69 1
14S
-0.57 10 2A 69 1
16S 0
34 2A 69 2
16S
-0.69 15 2A 69 2
14S
-0.52 10 2A 69 3
16S
-0.71 13 2A 69 4
16S
-0.65 16 2A 69 5
15S
-0.59 17 2A 69 6
15S
-0.61 13 2A 69 10 15S
-0.61 17 2A 69 12 16S 0.31 14 2A 69 12 16S
-0.6 20 2A 69 14 16S
-0.6 15 2A 69 23 16S
-0.72 17 2A 69 24 16S 0.48 14 2A 69 29 16S 0.36 11 2A 69 36 13S
-0.54 11 2A 69 41 16S
-0.78 13 2A 69 116 15S
-0.61 11 2A 69 117 15S 0.45 20 2A 69 128 16S
-0.64 11 2A 69 129 16S
-0.61 15 2A 69 130 16S
-0.14 40 2A 69 131 16S
-0.11 29 2A 69 132 13S
-0.36 8
2A 70 3
16S
-0.14 20 2A 70 3
15S
-0.05 31 2A 70 7
15S
-0.59 9
Attachment L-22-211 Page 28 of 89 SG Row Tube TSP INCH
%TW 2A 70 7
16S 0.45 13 2A 70 8
15S
-0.61 15 2A 70 13 16S
-0.55 13 2A 70 23 16S
-0.72 19 2A 70 35 16S
-0.62 16 2A 70 47 16S 0.43 13 2A 70 51 16S
-0.85 9
2A 70 94 15S
-0.7 6
2A 70 113 15S 0.43 21 2A 70 113 15S
-0.61 12 2A 70 114 15S 0.45 12 2A 70 116 15S 0.41 15 2A 70 122 16S
-0.11 17 2A 70 126 16S
-0.63 14 2A 70 128 16S
-0.59 13 2A 70 129 16S
-0.14 41 2A 70 130 16S
-0.11 28 2A 70 131 16S
-0.11 28 2A 71 1
16S
-0.14 28 2A 71 1
14S 0
26 2A 71 2
14S
-0.5 14 2A 71 2
16S 0
18 2A 71 4
15S 0.53 19 2A 71 4
15S
-0.64 16 2A 71 4
16S 0.4 14 2A 71 5
15S
-0.59 17 2A 71 6
16S
-0.69 14 2A 71 6
15S
-0.57 11 2A 71 7
16S
-0.69 15 2A 71 7
15S
-0.57 21 2A 71 14 16S
-0.59 16 2A 71 14 15S
-0.59 20 2A 71 18 15S
-0.62 8
2A 71 24 16S
-0.75 20 2A 71 25 16S
-0.63 12 2A 71 45 16S
-0.83 10 2A 71 47 16S 0.47 13 2A 71 97 15S
-0.61 13 2A 71 116 16S
-0.66 13 2A 71 126 16S
-0.68 12 2A 71 127 16S
-0.68 15 2A 71 128 16S
-0.59 14
Attachment L-22-211 Page 29 of 89 SG Row Tube TSP INCH
%TW 2A 71 129 16S
-0.61 14 2A 71 131 16S
-0.11 24 2A 72 3
15S
-0.64 16 2A 72 4
16S
-0.7 14 2A 72 4
15S
-0.59 17 2A 72 8
16S 0
23 2A 72 10 16S
-0.61 13 2A 72 13 16S
-0.57 14 2A 72 20 16S
-0.55 11 2A 72 24 15S
-0.57 17 2A 72 29 16S
-0.62 12 2A 72 34 16S 0.36 10 2A 72 41 13S
-0.45 11 2A 72 48 16S
-0.78 14 2A 72 108 15S 0.43 15 2A 72 108 15S
-0.61 19 2A 72 109 15S 0.45 13 2A 72 114 15S 0.41 16 2A 72 114 15S
-0.61 13 2A 72 121 16S
-0.61 7
2A 72 128 16S
-0.14 33 2A 72 129 16S 0.34 31 2A 72 129 16S
-0.7 34 2A 72 130 16S
-0.7 27 2A 72 131 16S
-0.11 28 2A 73 1
16S
-0.16 26 2A 73 1
14S
-0.5 17 2A 73 1
13S 0
12 2A 73 2
14S
-0.5 13 2A 73 3
16S 0.36 12 2A 73 3
16S
-0.62 18 2A 73 3
15S
-0.67 24 2A 73 4
15S
-0.62 13 2A 73 4
16S 0
16 2A 73 5
15S
-0.59 17 2A 73 6
15S
-0.59 11 2A 73 8
16S
-0.7 14 2A 73 24 16S
-0.73 14 2A 73 26 16S
-0.59 14 2A 73 28 16S
-0.55 13 2A 73 38 16S 0.38 12 2A 73 41 16S
-0.67 13
Attachment L-22-211 Page 30 of 89 SG Row Tube TSP INCH
%TW 2A 73 46 16S
-0.78 13 2A 73 102 15S
-0.16 13 2A 73 109 15S
-0.61 21 2A 73 113 15S
-0.61 7
2A 73 115 15S 0.39 16 2A 73 115 15S
-0.59 16 2A 73 120 15S 0.43 22 2A 73 127 16S
-0.61 16 2A 73 128 16S
-0.63 13 2A 73 129 16S
-0.11 32 2A 73 130 16S
-0.68 17 2A 73 130 16S 0.45 12 2A 73 131 16S
-0.64 20 2A 74 1
14S
-0.57 11 2A 74 3
15S 0.48 14 2A 74 3
15S
-0.59 16 2A 74 6
15S 0.46 12 2A 74 8
15S
-0.55 18 2A 74 9
15S
-0.59 15 2A 74 11 16S
-0.53 11 2A 74 11 15S
-0.59 13 2A 74 12 16S
-0.57 12 2A 74 12 15S
-0.61 15 2A 74 20 16S
-0.57 14 2A 74 32 16S 0.39 12 2A 74 32 13S
-0.53 14 2A 74 42 16S 0.29 12 2A 74 48 16S
-0.87 11 2A 74 55 16S 0.48 12 2A 74 96 15S 0.37 15 2A 74 96 15S
-0.64 17 2A 74 102 15S
-0.64 9
2A 74 110 16S
-0.63 11 2A 74 112 15S 0.43 14 2A 74 117 15S
-0.61 14 2A 74 127 16S
-0.61 12 2A 74 128 16S
-0.11 29 2A 74 129 16S
-0.63 26 2A 74 130 16S
-0.11 30 2A 74 131 13S
-0.55 6
2A 74 131 16S
-0.11 30 2A 75 1
16S
-0.11 24
Attachment L-22-211 Page 31 of 89 SG Row Tube TSP INCH
%TW 2A 75 1
14S
-0.55 11 2A 75 2
14S
-0.55 13 2A 75 3
16S 0.45 18 2A 75 3
15S 0
22 2A 75 4
15S 0
19 2A 75 5
16S 0.5 18 2A 75 5
15S
-0.57 15 2A 75 6
16S 0.47 14 2A 75 7
15S 0
19 2A 75 9
15S
-0.57 17 2A 75 12 16S
-0.58 12 2A 75 12 15S
-0.57 23 2A 75 27 16S
-0.74 10 2A 75 29 15S
-0.65 9
2A 75 33 16S 0.43 12 2A 75 42 16S 0.31 13 2A 75 45 16S 0.45 18 2A 75 47 16S 0.48 12 2A 75 48 16S 0.43 12 2A 75 104 15S 0.43 13 2A 75 104 15S
-0.62 16 2A 75 105 16S
-0.64 12 2A 75 109 15S
-0.62 19 2A 75 119 15S
-0.11 13 2A 75 120 16S
-0.66 13 2A 75 121 15S 0.43 18 2A 75 123 16S
-0.61 12 2A 75 124 16S
-0.16 19 2A 75 127 16S
-0.7 11 2A 75 128 16S
-0.09 34 2A 75 130 16S
-0.09 26 2A 75 131 16S
-0.57 18 2A 75 131 11S 0.57 20 2A 76 3
15S
-0.59 25 2A 76 35 16S
-0.67 12 2A 76 40 14S
-0.7 11 2A 76 107 15S 0.43 12 2A 76 120 16S
-0.57 13 2A 76 123 16S
-0.07 19 2A 76 124 16S
-0.66 25 2A 76 126 16S
-0.59 17 2A 76 127 16S
-0.14 30
Attachment L-22-211 Page 32 of 89 SG Row Tube TSP INCH
%TW 2A 76 129 16S
-0.14 38 2A 76 130 16S 0.3 22 2A 76 130 16S
-0.61 25 2A 77 1
16S 0.53 24 2A 77 1
14S 0.48 10 2A 77 1
14S
-0.5 21 2A 77 2
14S 0.48 13 2A 77 2
14S
-0.55 17 2A 77 2
13S
-0.5 8
2A 77 3
15S
-0.64 14 2A 77 4
14S
-0.53 11 2A 77 4
16S 0
13 2A 77 5
15S 0.46 22 2A 77 111 15S 0.36 16 2A 77 111 15S
-0.61 6
2A 77 119 15S
-0.59 15 2A 77 124 16S
-0.68 14 2A 77 125 16S
-0.66 10 2A 77 127 16S
-0.68 24 2A 77 127 16S 0.47 14 2A 77 129 16S 0.37 26 2A 77 129 16S
-0.45 36 2A 77 130 16S
-0.61 22 2A 77 131 16S
-0.57 24 2A 78 1
16S 0.53 21 2A 78 1
14S 0.5 16 2A 78 1
14S
-0.52 30 2A 78 1
13S 0.52 13 2A 78 2
16S 0.3 16 2A 78 3
16S 0.38 16 2A 78 5
15S
-0.45 11 2A 78 6
15S
-0.05 28 2A 78 28 16S
-0.62 9
2A 78 43 16S
-0.64 9
2A 78 106 15S 0.46 12 2A 78 106 15S
-0.61 14 2A 78 116 15S 0.34 13 2A 78 121 15S
-0.07 24 2A 78 122 16S
-0.7 14 2A 78 127 16S
-0.09 26 2A 78 129 16S
-0.09 26 2A 78 130 16S
-0.66 15
Attachment L-22-211 Page 33 of 89 SG Row Tube TSP INCH
%TW 2A 78 131 16S
-0.43 34 2A 79 1
16S 0
34 2A 79 1
14S 0
25 2A 79 2
14S 0.5 12 2A 79 2
14S
-0.55 16 2A 79 3
15S 0.51 20 2A 79 3
16S 0
27 2A 79 7
16S
-0.68 11 2A 79 13 14S
-0.52 17 2A 79 108 15S 0.41 12 2A 79 115 15S 0.45 10 2A 79 117 15S
-0.07 13 2A 79 122 16S
-0.14 20 2A 79 126 16S
-0.68 17 2A 79 129 16S
-0.68 16 2A 79 130 16S
-0.64 16 2A 79 131 16S
-0.68 24 2A 80 30 16S
-0.74 11 2A 80 45 16S
-0.71 11 2A 80 110 16S
-0.59 11 2A 80 114 15S
-0.62 13 2A 80 114 15S 0.43 13 2A 80 129 16S
-0.57 24 2A 80 131 16S
-0.11 37 2A 81 1
16S
-0.11 30 2A 81 8
15S
-0.54 10 2A 81 32 16S
-0.76 12 2A 81 46 16S
-0.7 13 2A 81 112 15S
-0.64 14 2A 81 115 15S
-0.62 12 2A 81 116 16S
-0.61 10 2A 81 129 16S
-0.59 16 2A 81 130 16S
-0.57 19 2A 81 131 16S
-0.48 30 2A 82 1
14S
-0.55 10 2A 82 2
16S
-0.11 17 2A 82 6
14S 0
23 2A 82 10 16S
-0.55 13 2A 82 107 15S 0.41 17 2A 82 107 15S
-0.59 21 2A 82 114 15S
-0.59 9
2A 82 115 16S
-0.61 14
Attachment L-22-211 Page 34 of 89 SG Row Tube TSP INCH
%TW 2A 82 120 16S
-0.61 10 2A 82 121 15S
-0.09 17 2A 82 124 16S
-0.57 14 2A 82 127 16S
-0.61 13 2A 82 128 16S
-0.59 19 2A 82 129 16S
-0.09 31 2A 82 131 16S
-0.61 14 2A 83 1
13S 0.53 13 2A 83 1
14S
-0.02 30 2A 83 6
14S 0
24 2A 83 115 15S
-0.59 14 2A 83 121 15S
-0.57 15 2A 83 122 16S
-0.61 11 2A 83 122 15S 0.41 16 2A 83 127 16S
-0.57 10 2A 83 128 16S
-0.61 11 2A 83 131 16S
-0.07 33 2A 83 132 13S
-0.36 12 2A 83 132 11S
-0.34 9
2A 84 1
16S
-0.11 36 2A 84 1
14S 0.5 13 2A 84 1
14S
-0.52 15 2A 84 3
15S
-0.61 13 2A 84 32 16S
-0.67 16 2A 84 45 16S
-0.65 14 2A 84 103 15S
-0.59 9
2A 84 106 15S 0.37 15 2A 84 106 15S
-0.55 16 2A 84 114 15S
-0.57 14 2A 84 118 15S 0.41 15 2A 84 118 15S
-0.57 13 2A 84 124 16S
-0.57 15 2A 84 126 16S 0.28 21 2A 84 127 16S
-0.11 20 2A 84 130 16S
-0.61 11 2A 84 131 16S
-0.55 30 2A 85 2
14S
-0.52 14 2A 85 7
16S
-0.58 15 2A 85 33 16S
-0.71 9
2A 85 106 16S
-0.59 11 2A 85 106 15S
-0.57 18 2A 85 123 16S
-0.11 24
Attachment L-22-211 Page 35 of 89 SG Row Tube TSP INCH
%TW 2A 85 128 16S
-0.61 20 2A 85 129 16S
-0.55 23 2A 85 130 16S
-0.55 17 2A 86 2
14S 0
18 2A 86 6
14S
-0.52 11 2A 86 7
16S
-0.45 12 2A 86 8
16S
-0.59 9
2A 86 29 16S
-0.74 13 2A 86 29 14S
-0.57 14 2A 86 43 16S
-0.7 14 2A 86 95 15S
-0.59 10 2A 86 114 15S 0.45 13 2A 86 120 16S
-0.59 12 2A 86 121 16S
-0.11 24 2A 86 122 16S
-0.14 23 2A 86 123 16S
-0.14 28 2A 86 125 16S
-0.57 14 2A 86 126 16S
-0.63 13 2A 86 127 16S
-0.09 24 2A 86 128 16S
-0.11 21 2A 86 129 16S
-0.11 34 2A 86 130 16S
-0.59 21 2A 86 131 16S
-0.41 32 2A 87 6
15S
-0.59 9
2A 87 30 14S
-0.52 15 2A 87 34 16S
-0.73 14 2A 87 106 15S
-0.59 15 2A 87 120 16S
-0.59 21 2A 87 122 16S
-0.11 16 2A 87 124 16S
-0.09 21 2A 87 126 16S
-0.61 18 2A 87 128 16S
-0.55 12 2A 87 129 16S
-0.46 27 2A 87 130 16S
-0.14 35 2A 88 1
16S
-0.11 33 2A 88 1
14S
-0.52 10 2A 88 2
14S 0.5 12 2A 88 2
14S
-0.55 16 2A 88 4
14S
-0.55 12 2A 88 10 16S
-0.63 11 2A 88 41 16S
-0.69 13 2A 88 41 13S
-0.54 13
Attachment L-22-211 Page 36 of 89 SG Row Tube TSP INCH
%TW 2A 88 49 16S
-0.72 10 2A 88 54 16S
-0.74 10 2A 88 55 16S
-0.77 12 2A 88 107 15S
-0.64 12 2A 88 113 15S
-0.61 8
2A 88 116 15S
-0.59 8
2A 88 121 16S
-0.66 14 2A 88 126 16S
-0.55 15 2A 88 127 16S 0.3 25 2A 88 127 16S
-0.59 31 2A 88 129 16S
-0.59 18 2A 88 130 16S
-0.59 16 2A 89 4
15S
-0.57 14 2A 89 10 14S 0.38 10 2A 89 21 16S
-0.71 9
2A 89 42 16S
-0.69 16 2A 89 95 16S 0.31 12 2A 89 108 16S
-0.16 16 2A 89 109 15S
-0.64 12 2A 89 113 15S
-0.07 12 2A 89 119 15S
-0.59 16 2A 89 121 16S
-0.65 11 2A 89 123 16S
-0.55 16 2A 89 126 16S
-0.09 30 2A 89 127 16S 0.32 23 2A 89 127 16S
-0.59 29 2A 89 129 16S
-0.59 21 2A 89 130 16S 0.02 36 2A 90 1
14S
-0.52 12 2A 90 3
14S
-0.57 12 2A 90 9
16S
-0.58 9
2A 90 19 16S
-0.7 10 2A 90 26 16S
-0.59 9
2A 90 70 16S
-0.84 15 2A 90 109 15S
-0.64 14 2A 90 114 15S
-0.59 10 2A 90 115 16S 0.36 15 2A 90 121 16S
-0.59 14 2A 90 125 16S
-0.63 14 2A 90 126 16S 0.34 15 2A 90 126 16S
-0.57 23 2A 90 127 16S
-0.59 26
Attachment L-22-211 Page 37 of 89 SG Row Tube TSP INCH
%TW 2A 90 128 16S
-0.52 25 2A 90 129 16S 0.26 22 2A 90 129 16S
-0.61 32 2A 91 1
14S
-0.53 10 2A 91 2
14S
-0.52 17 2A 91 3
14S
-0.56 17 2A 91 4
16S
-0.09 15 2A 91 19 16S
-0.7 9
2A 91 19 15S
-0.55 12 2A 91 21 16S
-0.62 11 2A 91 24 16S
-0.72 10 2A 91 27 16S 0.36 11 2A 91 39 16S
-0.69 13 2A 91 42 16S 0.29 8
2A 91 80 16S
-0.59 13 2A 91 91 16S
-0.61 10 2A 91 113 15S
-0.09 17 2A 91 115 16S
-0.63 15 2A 91 116 16S
-0.6 16 2A 91 117 15S 0.44 14 2A 91 122 16S
-0.12 34 2A 91 123 16S
-0.61 22 2A 91 124 16S
-0.57 21 2A 91 125 16S
-0.59 15 2A 91 127 16S
-0.61 17 2A 91 128 16S
-0.61 34 2A 91 129 16S 0.41 17 2A 91 129 16S
-0.57 23 2A 92 1
16S
-0.11 33 2A 92 35 16S
-0.78 13 2A 92 38 16S
-0.68 14 2A 92 40 16S
-0.65 13 2A 92 42 16S
-0.71 13 2A 92 44 13S
-0.48 13 2A 92 91 16S
-0.56 12 2A 92 93 14S 0.47 9
2A 92 105 15S
-0.59 15 2A 92 106 15S
-0.6 13 2A 92 107 15S
-0.62 13 2A 92 122 16S
-0.12 23 2A 92 124 16S
-0.58 14 2A 92 125 16S
-0.07 24
Attachment L-22-211 Page 38 of 89 SG Row Tube TSP INCH
%TW 2A 92 128 16S
-0.49 31 2A 92 129 16S
-0.07 34 2A 93 1
14S
-0.53 17 2A 93 8
15S 0.4 14 2A 93 16 16S
-0.52 10 2A 93 37 13S
-0.52 11 2A 93 41 16S 0.27 11 2A 93 43 16S
-0.71 11 2A 93 102 16S
-0.6 16 2A 93 105 16S 0.31 13 2A 93 120 16S
-0.58 15 2A 93 123 16S
-0.61 11 2A 93 124 16S
-0.58 16 2A 93 125 16S
-0.58 13 2A 93 126 16S
-0.58 18 2A 93 128 16S
-0.53 9
2A 94 1
14S
-0.6 9
2A 94 6
15S
-0.07 17 2A 94 14 16S
-0.59 9
2A 94 18 16S
-0.62 11 2A 94 20 16S
-0.7 10 2A 94 21 14S
-0.57 13 2A 94 26 16S
-0.65 14 2A 94 27 16S
-0.72 12 2A 94 37 16S
-0.7 10 2A 94 43 16S
-0.71 15 2A 94 91 16S
-0.6 14 2A 94 93 16S
-0.67 14 2A 94 103 15S
-0.57 20 2A 94 105 15S
-0.63 6
2A 94 116 16S
-0.59 14 2A 94 122 16S
-0.63 19 2A 94 123 16S
-0.6 17 2A 94 124 16S
-0.62 12 2A 94 126 16S
-0.56 18 2A 94 127 16S
-0.58 29 2A 94 128 16S
-0.56 21 2A 95 1
16S
-0.07 38 2A 95 1
14S
-0.57 10 2A 95 2
14S
-0.6 12 2A 95 16 16S
-0.6 10 2A 95 19 16S
-0.53 12
Attachment L-22-211 Page 39 of 89 SG Row Tube TSP INCH
%TW 2A 95 20 16S
-0.58 10 2A 95 32 16S
-0.71 13 2A 95 38 16S
-0.61 16 2A 95 40 16S
-0.6 23 2A 95 58 16S
-0.73 15 2A 95 93 16S
-0.6 16 2A 95 96 15S
-0.62 14 2A 95 105 15S 0.36 14 2A 95 110 16S 0.31 12 2A 95 110 16S
-0.58 14 2A 95 114 15S
-0.11 19 2A 95 121 16S
-0.6 13 2A 95 125 16S
-0.58 14 2A 95 126 16S
-0.16 28 2A 95 127 16S 0.28 15 2A 95 127 16S
-0.44 24 2A 96 3
14S
-0.56 11 2A 96 15 16S
-0.7 9
2A 96 18 16S
-0.6 14 2A 96 20 16S
-0.11 14 2A 96 29 14S
-0.54 11 2A 96 38 16S
-0.14 17 2A 96 103 15S 0.36 11 2A 96 104 15S
-0.64 16 2A 96 110 15S
-0.59 10 2A 96 118 16S
-0.12 26 2A 96 120 16S
-0.58 14 2A 96 124 16S
-0.09 25 2A 96 125 16S
-0.56 27 2A 96 126 16S
-0.58 13 2A 96 127 16S
-0.07 34 2A 97 4
15S
-0.07 17 2A 97 28 16S
-0.71 15 2A 97 30 14S
-0.55 15 2A 97 33 16S
-0.76 12 2A 97 41 14S
-0.61 13 2A 97 49 16S
-0.52 19 2A 97 109 16S
-0.61 12 2A 97 112 15S 0
15 2A 97 114 16S
-0.58 10 2A 97 120 16S
-0.6 11 2A 97 124 16S
-0.55 15
Attachment L-22-211 Page 40 of 89 SG Row Tube TSP INCH
%TW 2A 97 126 16S
-0.12 38 2A 98 1
14S
-0.55 18 2A 98 8
15S 0.42 12 2A 98 15 16S
-0.57 13 2A 98 24 16S
-0.6 8
2A 98 28 16S
-0.62 17 2A 98 40 16S
-0.68 11 2A 98 94 16S 0
14 2A 98 97 16S
-0.57 12 2A 98 100 15S 0.39 14 2A 98 101 15S
-0.6 12 2A 98 106 16S 0.24 11 2A 98 108 15S
-0.64 10 2A 98 112 16S
-0.57 11 2A 98 112 15S
-0.59 12 2A 98 113 16S
-0.6 15 2A 98 122 16S
-0.58 16 2A 98 123 16S
-0.56 10 2A 98 124 16S
-0.09 34 2A 98 125 16S
-0.58 22 2A 98 126 16S
-0.56 17 2A 99 29 14S
-0.57 16 2A 99 42 16S
-0.64 21 2A 99 49 16S
-0.73 12 2A 99 93 16S
-0.57 15 2A 99 112 16S
-0.54 12 2A 99 115 15S
-0.59 9
2A 99 120 16S
-0.58 12 2A 99 122 16S
-0.55 18 2A 99 123 16S
-0.56 11 2A 99 124 16S
-0.56 26 2A 99 125 16S
-0.53 23 2A 100 1
16S
-0.09 25 2A 100 2
14S
-0.62 10 2A 100 5
15S 0.45 13 2A 100 13 14S
-0.52 14 2A 100 27 16S
-0.59 12 2A 100 28 16S
-0.64 13 2A 100 34 16S
-0.63 21 2A 100 39 16S
-0.49 21 2A 100 61 11S
-0.65 7
2A 100 104 15S
-0.6 11
Attachment L-22-211 Page 41 of 89 SG Row Tube TSP INCH
%TW 2A 100 111 16S
-0.57 11 2A 100 123 16S
-0.56 15 2A 100 124 16S
-0.57 13 2A 100 125 16S
-0.09 21 2A 101 7
15S
-0.56 12 2A 101 16 14S
-0.55 14 2A 101 36 16S
-0.63 15 2A 101 38 16S
-0.63 17 2A 101 61 16S
-0.8 14 2A 101 62 16S
-0.67 13 2A 101 88 15S 0.43 10 2A 101 91 15S 0.43 11 2A 101 94 15S
-0.64 11 2A 101 119 16S
-0.57 10 2A 101 122 16S
-0.57 20 2A 101 123 16S
-0.58 25 2A 101 124 16S 0.28 18 2A 101 124 16S
-0.54 27 2A 102 28 14S
-0.57 10 2A 102 41 16S
-0.14 17 2A 102 56 16S
-0.68 17 2A 102 76 15S 0.38 10 2A 102 87 15S
-0.62 9
2A 102 89 15S
-0.63 20 2A 102 91 15S 0.34 17 2A 102 91 15S
-0.63 17 2A 102 115 16S
-0.73 18 2A 102 119 16S
-0.11 22 2A 102 122 16S
-0.56 19 2A 103 1
14S
-0.55 15 2A 103 2
14S
-0.57 17 2A 103 5
15S
-0.61 18 2A 103 36 16S
-0.68 13 2A 103 44 16S 0.13 14 2A 103 52 16S
-0.74 13 2A 103 62 16S
-0.76 16 2A 103 116 15S 0.51 12 2A 103 118 16S
-0.6 13 2A 103 119 16S
-0.12 18 2A 103 120 16S
-0.12 18 2A 103 122 16S
-0.6 12 2A 103 123 16S
-0.14 15
Attachment L-22-211 Page 42 of 89 SG Row Tube TSP INCH
%TW 2A 104 1
14S
-0.55 12 2A 104 2
14S
-0.59 13 2A 104 4
14S
-0.55 13 2A 104 5
15S
-0.52 17 2A 104 31 16S
-0.76 16 2A 104 41 16S
-0.7 11 2A 104 45 16S
-0.74 18 2A 104 46 16S
-0.71 13 2A 104 47 16S
-0.65 13 2A 104 50 16S
-0.73 14 2A 104 52 16S
-0.67 12 2A 104 56 16S
-0.54 14 2A 104 60 16S
-0.78 17 2A 104 85 15S
-0.61 14 2A 104 88 16S 0.31 13 2A 104 88 15S
-0.61 22 2A 104 96 15S
-0.05 14 2A 104 97 16S
-0.59 13 2A 104 99 15S 0.41 16 2A 104 100 15S
-0.62 13 2A 104 102 15S 0.39 12 2A 104 119 16S 0.26 11 2A 104 120 16S
-0.57 9
2A 104 121 16S
-0.11 23 2A 104 122 16S
-0.5 10 2A 104 123 16S 0
33 2A 105 35 16S
-0.63 13 2A 105 37 16S
-0.65 15 2A 105 44 16S
-0.72 18 2A 105 49 16S
-0.6 15 2A 105 52 16S
-0.7 16 2A 105 55 16S
-0.71 12 2A 105 57 16S 0.48 11 2A 105 60 16S
-0.76 14 2A 105 90 15S 0.34 12 2A 105 90 15S
-0.59 10 2A 105 96 15S 0
10 2A 105 99 15S 0.39 14 2A 105 99 15S
-0.6 13 2A 105 118 16S 0.33 8
2A 105 119 16S
-0.57 23 2A 105 120 16S
-0.43 16
Attachment L-22-211 Page 43 of 89 SG Row Tube TSP INCH
%TW 2A 105 121 16S
-0.41 20 2A 105 122 16S
-0.14 38 2A 106 34 16S
-0.64 13 2A 106 35 16S
-0.64 11 2A 106 40 09S 0.05 12 2A 106 41 16S
-0.72 19 2A 106 42 16S
-0.52 15 2A 106 43 16S
-0.14 15 2A 106 46 16S
-0.49 18 2A 106 55 16S
-0.76 9
2A 106 78 15S
-0.65 12 2A 106 85 15S
-0.78 6
2A 106 101 15S
-0.55 12 2A 106 103 15S
-0.62 12 2A 106 111 16S
-0.55 13 2A 106 116 16S
-0.55 11 2A 106 118 16S
-0.55 15 2A 106 120 16S
-0.09 25 2A 106 121 16S
-0.11 34 2A 107 1
14S
-0.6 11 2A 107 22 16S
-0.62 13 2A 107 37 16S
-0.68 10 2A 107 39 16S
-0.72 12 2A 107 43 16S
-0.69 13 2A 107 46 16S
-0.58 12 2A 107 48 16S
-0.49 14 2A 107 50 16S
-0.72 18 2A 107 51 16S
-0.71 18 2A 107 51 14S
-0.59 22 2A 107 74 15S
-0.63 11 2A 107 79 15S
-0.63 14 2A 107 83 15S
-0.61 18 2A 107 85 15S 0.38 12 2A 107 87 15S
-0.57 11 2A 107 90 15S
-0.59 10 2A 107 94 15S
-0.56 13 2A 107 95 15S 0.38 12 2A 107 101 15S 0
14 2A 107 114 16S
-0.55 11 2A 107 115 16S
-0.57 16 2A 107 118 16S
-0.55 25 2A 107 120 16S
-0.07 31
Attachment L-22-211 Page 44 of 89 SG Row Tube TSP INCH
%TW 2A 108 31 16S
-0.67 12 2A 108 40 16S
-0.67 14 2A 108 41 16S
-0.68 15 2A 108 44 16S
-0.75 15 2A 108 46 16S
-0.65 18 2A 108 47 16S
-0.65 13 2A 108 49 16S
-0.73 16 2A 108 51 16S
-0.7 10 2A 108 53 16S
-0.54 18 2A 108 56 16S
-0.78 9
2A 108 59 16S
-0.82 13 2A 108 78 15S
-0.59 14 2A 108 85 15S 0.4 13 2A 108 86 15S 0.36 13 2A 108 99 15S 0
14 2A 108 113 16S
-0.55 13 2A 108 118 16S
-0.07 22 2A 108 119 16S
-0.07 31 2A 109 4
14S
-0.55 18 2A 109 21 16S
-0.61 13 2A 109 31 16S
-0.61 11 2A 109 40 16S
-0.56 13 2A 109 41 16S
-0.68 20 2A 109 42 16S
-0.73 17 2A 109 44 16S
-0.7 19 2A 109 47 16S
-0.67 14 2A 109 51 16S
-0.65 16 2A 109 52 16S
-0.65 17 2A 109 55 16S 0.45 10 2A 109 55 16S
-0.77 17 2A 109 58 16S
-0.75 14 2A 109 89 16S
-0.54 10 2A 109 89 15S
-0.57 9
2A 109 94 15S 0.41 12 2A 109 94 15S
-0.57 13 2A 109 117 16S
-0.55 13 2A 110 20 16S
-0.78 16 2A 110 31 16S
-0.63 15 2A 110 36 14S
-0.57 14 2A 110 37 16S
-0.47 13 2A 110 37 14S
-0.5 15 2A 110 40 16S
-0.73 18
Attachment L-22-211 Page 45 of 89 SG Row Tube TSP INCH
%TW 2A 110 43 16S
-0.71 21 2A 110 46 16S
-0.71 17 2A 110 47 16S
-0.65 14 2A 110 49 16S
-0.7 12 2A 110 51 16S
-0.67 18 2A 110 54 16S
-0.73 13 2A 110 85 15S
-0.64 15 2A 110 86 15S 0.43 12 2A 110 86 15S
-0.66 13 2A 110 87 15S
-0.61 15 2A 110 112 16S
-0.55 14 2A 110 114 16S
-0.57 15 2A 110 116 16S
-0.55 15 2A 110 117 16S
-0.09 28 2A 111 4
15S
-0.54 11 2A 111 29 16S
-0.65 13 2A 111 31 16S
-0.64 11 2A 111 36 14S
-0.57 14 2A 111 39 16S
-0.56 19 2A 111 41 16S
-0.54 20 2A 111 42 16S
-0.68 14 2A 111 43 16S
-0.65 18 2A 111 45 16S
-0.68 19 2A 111 49 16S
-0.73 14 2A 111 52 16S
-0.58 25 2A 111 53 16S
-0.77 13 2A 111 57 16S
-0.76 11 2A 111 73 15S
-0.61 11 2A 111 82 15S 0.43 12 2A 111 87 15S
-0.67 11 2A 111 93 15S 0.41 16 2A 111 113 16S
-0.11 20 2A 111 114 16S
-0.09 18 2A 111 115 16S
-0.55 18 2A 112 1
14S
-0.05 26 2A 112 5
14S
-0.55 10 2A 112 6
14S
-0.53 13 2A 112 7
15S 0.44 13 2A 112 37 16S
-0.68 14 2A 112 39 16S
-0.68 14 2A 112 40 16S
-0.66 19 2A 112 43 16S
-0.7 11
Attachment L-22-211 Page 46 of 89 SG Row Tube TSP INCH
%TW 2A 112 44 16S
-0.68 17 2A 112 50 16S
-0.16 21 2A 112 51 16S
-0.69 13 2A 112 54 16S
-0.72 16 2A 112 81 15S 0.41 12 2A 112 82 15S
-0.64 13 2A 112 84 15S
-0.14 15 2A 112 94 15S 0
20 2A 112 112 15S 0.41 17 2A 112 113 16S
-0.09 23 2A 112 114 16S
-0.54 22 2A 112 115 16S
-0.52 22 2A 112 116 16S
-0.5 17 2A 113 6
14S
-0.54 12 2A 113 7
14S
-0.54 11 2A 113 8
14S
-0.58 11 2A 113 29 16S
-0.63 13 2A 113 30 16S
-0.65 11 2A 113 31 16S
-0.67 15 2A 113 40 16S
-0.47 18 2A 113 41 16S
-0.73 27 2A 113 43 16S
-0.65 17 2A 113 44 16S
-0.66 18 2A 113 46 16S
-0.66 13 2A 113 47 16S
-0.67 17 2A 113 51 16S
-0.71 12 2A 113 52 16S
-0.71 10 2A 113 55 16S
-0.72 11 2A 113 58 16S
-0.71 9
2A 113 67 16S
-0.63 11 2A 113 83 15S
-0.11 19 2A 113 86 16S 0.34 12 2A 113 89 15S 0.32 9
2A 113 90 15S 0.43 14 2A 113 92 15S
-0.59 12 2A 113 114 16S
-0.55 18 2A 113 115 16S
-0.52 15 2A 114 6
15S
-0.55 13 2A 114 29 16S
-0.65 16 2A 114 30 16S
-0.67 13 2A 114 32 16S
-0.66 11 2A 114 38 16S
-0.69 14
Attachment L-22-211 Page 47 of 89 SG Row Tube TSP INCH
%TW 2A 114 39 16S
-0.72 15 2A 114 41 16S
-0.67 20 2A 114 44 16S
-0.65 11 2A 114 45 16S
-0.71 14 2A 114 49 16S
-0.72 18 2A 114 53 16S
-0.72 17 2A 114 54 16S
-0.71 14 2A 114 79 15S
-0.62 24 2A 114 80 15S
-0.6 13 2A 114 82 15S
-0.63 14 2A 114 115 16S
-0.5 25 2A 115 1
14S
-0.55 13 2A 115 29 16S
-0.69 24 2A 115 32 16S
-0.68 14 2A 115 37 16S
-0.64 16 2A 115 38 16S
-0.65 15 2A 115 40 16S
-0.72 11 2A 115 42 16S
-0.67 14 2A 115 44 16S
-0.68 16 2A 115 47 16S
-0.67 13 2A 115 48 16S
-0.78 15 2A 115 49 16S
-0.71 18 2A 115 81 15S
-0.11 22 2A 115 86 15S
-0.54 14 2A 115 91 15S
-0.64 14 2A 115 97 16S
-0.09 15 2A 115 109 16S
-0.54 12 2A 115 114 16S
-0.11 38 2A 116 1
16S
-0.11 21 2A 116 1
14S
-0.57 12 2A 116 8
14S
-0.59 10 2A 116 27 16S
-0.63 12 2A 116 29 16S
-0.61 16 2A 116 31 16S
-0.65 16 2A 116 32 16S
-0.14 16 2A 116 36 16S
-0.7 12 2A 116 37 16S
-0.68 14 2A 116 38 16S
-0.56 20 2A 116 40 16S
-0.65 14 2A 116 42 16S
-0.68 17 2A 116 43 16S
-0.66 22 2A 116 45 14S
-0.56 14
Attachment L-22-211 Page 48 of 89 SG Row Tube TSP INCH
%TW 2A 116 48 16S
-0.61 23 2A 116 49 16S
-0.63 14 2A 116 51 16S
-0.68 21 2A 116 63 15S
-0.66 9
2A 116 88 15S 0.48 11 2A 116 110 16S
-0.61 20 2A 116 111 16S
-0.11 28 2A 116 112 16S
-0.11 21 2A 117 1
14S
-0.54 10 2A 117 20 16S
-0.6 13 2A 117 22 16S
-0.63 13 2A 117 28 16S
-0.63 9
2A 117 31 16S
-0.63 12 2A 117 32 16S
-0.59 13 2A 117 33 16S
-0.54 15 2A 117 36 16S
-0.63 18 2A 117 38 16S
-0.7 14 2A 117 39 16S
-0.7 16 2A 117 40 16S
-0.68 15 2A 117 41 16S
-0.57 14 2A 117 47 16S
-0.68 12 2A 117 49 13S
-0.54 10 2A 117 50 16S
-0.7 14 2A 117 51 16S
-0.76 15 2A 117 53 16S
-0.66 17 2A 117 55 16S
-0.73 15 2A 117 56 15S 0.34 10 2A 117 84 15S 0.42 14 2A 117 85 15S 0.32 12 2A 117 89 15S
-0.07 20 2A 117 109 16S
-0.59 20 2A 118 1
14S
-0.54 12 2A 118 2
14S 0
12 2A 118 5
15S 0.46 14 2A 118 19 14S
-0.57 10 2A 118 35 16S
-0.66 14 2A 118 41 16S
-0.7 13 2A 118 43 16S
-0.54 18 2A 118 44 16S
-0.16 17 2A 118 45 16S
-0.7 17 2A 118 46 16S
-0.72 18 2A 118 77 15S
-0.56 15
Attachment L-22-211 Page 49 of 89 SG Row Tube TSP INCH
%TW 2A 118 84 15S
-0.52 10 2A 118 90 15S
-0.62 12 2A 118 91 15S 0.39 9
2A 118 107 16S
-0.54 15 2A 118 108 16S
-0.59 16 2A 119 1
14S
-0.5 10 2A 119 21 16S
-0.63 12 2A 119 30 16S
-0.65 12 2A 119 31 16S
-0.51 23 2A 119 35 16S
-0.65 11 2A 119 37 16S
-0.64 16 2A 119 42 16S
-0.69 16 2A 119 43 16S 0.45 10 2A 119 44 16S
-0.71 13 2A 119 49 16S
-0.5 16 2A 119 73 15S 0.37 12 2A 119 77 15S
-0.56 12 2A 119 81 15S
-0.52 16 2A 119 82 15S
-0.57 10 2A 119 85 15S 0.4 13 2A 119 87 16S 0.4 9
2A 119 87 15S
-0.5 13 2A 119 88 15S 0.42 11 2A 119 89 15S
-0.55 12 2A 119 104 16S
-0.64 11 2A 119 106 16S 0
15 2A 120 1
16S 0.31 13 2A 120 19 16S
-0.63 18 2A 120 30 16S
-0.58 18 2A 120 31 16S
-0.47 18 2A 120 32 16S
-0.63 22 2A 120 42 16S
-0.69 18 2A 120 43 16S
-0.71 23 2A 120 44 16S 0.18 13 2A 120 45 16S
-0.74 14 2A 120 48 16S
-0.69 13 2A 120 49 16S
-0.73 12 2A 120 60 15S
-0.62 10 2A 120 70 15S
-0.58 11 2A 120 71 15S
-0.56 11 2A 120 74 15S 0.36 13 2A 120 84 15S
-0.53 14
Attachment L-22-211 Page 50 of 89 SG Row Tube TSP INCH
%TW 2A 120 104 16S
-0.61 14 2A 120 106 16S
-0.09 18 2A 121 1
14S
-0.52 12 2A 121 1
16S 0.4 15 2A 121 32 13S
-0.36 14 2A 121 37 16S
-0.71 13 2A 121 41 16S
-0.66 17 2A 121 43 16S
-0.65 20 2A 121 44 16S
-0.55 18 2A 121 45 16S
-0.69 18 2A 121 46 16S
-0.7 14 2A 121 51 16S
-0.72 15 2A 121 58 15S 0.4 14 2A 121 66 15S
-0.09 16 2A 121 72 15S
-0.59 11 2A 121 75 15S
-0.58 10 2A 121 78 15S 0.4 14 2A 121 103 16S
-0.66 14 2A 121 104 16S
-0.61 14 2A 121 105 16S
-0.54 17 2A 121 106 16S
-0.55 16 2A 122 1
16S
-0.11 22 2A 122 42 16S
-0.72 15 2A 122 43 16S
-0.56 14 2A 122 45 16S
-0.52 17 2A 122 47 16S
-0.73 15 2A 122 49 16S
-0.55 14 2A 122 59 15S
-0.09 14 2A 122 67 15S
-0.63 10 2A 122 71 15S
-0.57 11 2A 122 82 16S
-0.75 11 2A 122 82 15S
-0.07 25 2A 122 84 15S 0.33 15 2A 122 100 16S
-0.68 10 2A 122 102 16S
-0.54 11 2A 122 103 16S
-0.64 14 2A 122 105 16S
-0.09 31 2A 123 1
16S
-0.09 30 2A 123 1
14S
-0.07 23 2A 123 5
14S
-0.54 21 2A 123 6
15S 0.47 14 2A 123 19 15S 0.47 13
Attachment L-22-211 Page 51 of 89 SG Row Tube TSP INCH
%TW 2A 123 27 16S
-0.65 11 2A 123 28 16S
-0.63 19 2A 123 30 08S 0.66 17 2A 123 37 16S
-0.66 17 2A 123 38 16S
-0.58 15 2A 123 39 16S
-0.69 11 2A 123 42 16S
-0.73 17 2A 123 42 14S
-0.54 15 2A 123 44 16S
-0.63 16 2A 123 45 16S
-0.72 14 2A 123 51 16S
-0.67 13 2A 123 52 16S
-0.61 17 2A 123 89 15S
-0.47 12 2A 123 92 15S
-0.14 13 2A 123 101 16S
-0.64 16 2A 123 102 16S
-0.64 13 2A 123 103 16S
-0.11 28 2A 124 12 14S
-0.59 9
2A 124 37 16S
-0.66 11 2A 124 38 16S
-0.61 14 2A 124 42 16S
-0.55 14 2A 124 43 16S
-0.59 12 2A 124 44 16S
-0.57 11 2A 124 52 15S
-0.07 20 2A 124 75 15S
-0.52 15 2A 124 79 15S 0.45 13 2A 124 87 15S
-0.52 9
2A 124 98 16S
-0.65 13 2A 125 10 15S 0.45 13 2A 125 16 15S 0.3 14 2A 125 22 16S
-0.63 15 2A 125 41 16S
-0.71 13 2A 125 42 16S
-0.75 12 2A 125 47 16S
-0.71 13 2A 125 61 15S
-0.55 7
2A 125 74 15S
-0.05 22 2A 125 78 15S
-0.05 21 2A 125 84 16S
-0.87 15 2A 125 86 16S
-0.81 9
2A 125 94 16S 0
11 2A 125 98 16S
-0.54 11 2A 125 99 16S
-0.11 20
Attachment L-22-211 Page 52 of 89 SG Row Tube TSP INCH
%TW 2A 125 100 16S
-0.11 32 2A 126 1
16S
-0.12 33 2A 126 11 14S
-0.55 9
2A 126 37 16S
-0.69 15 2A 126 38 16S
-0.67 15 2A 126 39 16S
-0.66 17 2A 126 40 16S
-0.68 12 2A 126 44 16S
-0.54 17 2A 126 48 16S
-0.67 12 2A 126 81 16S
-0.83 14 2A 126 92 16S
-0.14 19 2A 126 99 16S
-0.11 31 2A 127 1
16S
-0.12 33 2A 127 1
14S
-0.5 19 2A 127 8
14S
-0.52 11 2A 127 9
16S
-0.61 14 2A 127 10 14S
-0.54 9
2A 127 19 14S
-0.54 9
2A 127 28 14S
-0.54 16 2A 127 31 16S
-0.69 14 2A 127 37 16S
-0.5 15 2A 127 42 16S
-0.59 17 2A 127 45 16S
-0.56 18 2A 127 49 16S
-0.58 16 2A 127 64 15S
-0.09 19 2A 127 66 15S
-0.57 10 2A 127 71 15S
-0.07 18 2A 127 96 16S
-0.14 15 2A 128 1
16S
-0.12 14 2A 128 1
14S
-0.52 11 2A 128 5
14S
-0.53 15 2A 128 6
15S 0.49 12 2A 128 8
15S 0.44 12 2A 128 33 16S
-0.74 13 2A 128 40 16S
-0.56 17 2A 128 43 16S
-0.7 13 2A 128 45 16S
-0.76 14 2A 128 63 15S 0.35 16 2A 128 92 16S
-0.66 18 2A 128 95 16S
-0.07 32 2A 129 1
16S
-0.12 22 2A 129 1
14S
-0.5 18
Attachment L-22-211 Page 53 of 89 SG Row Tube TSP INCH
%TW 2A 129 6
14S
-0.52 10 2A 129 7
16S
-0.65 11 2A 129 10 15S 0.49 15 2A 129 21 16S
-0.54 12 2A 129 36 16S
-0.69 16 2A 129 38 16S 0.38 7
2A 129 38 14S
-0.5 13 2A 129 43 15S 0.37 10 2A 129 45 16S
-0.76 11 2A 129 70 15S
-0.52 12 2A 129 77 15S
-0.57 12 2A 129 84 16S 0.53 12 2A 129 92 16S
-0.09 23 2A 129 94 16S
-0.11 30 2A 130 17 15S
-0.59 11 2A 130 35 16S
-0.68 13 2A 130 42 16S
-0.74 13 2A 130 45 16S
-0.74 15 2A 130 56 15S
-0.51 13 2A 130 89 16S 0.3 10 2A 131 1
16S 0.31 15 2A 131 1
14S
-0.52 14 2A 131 11 16S
-0.63 10 2A 131 11 14S
-0.52 11 2A 131 14 15S
-0.57 13 2A 131 16 16S
-0.58 10 2A 131 23 16S
-0.61 15 2A 131 23 14S
-0.52 23 2A 131 26 16S
-0.74 12 2A 131 31 16S
-0.67 15 2A 131 36 16S
-0.69 9
2A 131 38 16S
-0.78 11 2A 131 39 16S
-0.14 15 2A 131 45 16S
-0.69 11 2A 131 55 15S 0.5 11 2A 131 60 15S 0.37 15 2A 131 65 15S
-0.54 11 2A 131 67 15S
-0.55 15 2A 131 89 16S
-0.07 14 2A 131 90 16S
-0.59 14 2A 132 1
14S 0
15 2A 132 8
15S 0.47 14
Attachment L-22-211 Page 54 of 89 SG Row Tube TSP INCH
%TW 2A 132 11 16S
-0.61 9
2A 132 13 16S
-0.67 11 2A 132 14 16S
-0.53 11 2A 132 15 16S
-0.59 15 2A 132 15 15S 0.4 12 2A 132 15 15S
-0.56 11 2A 132 17 16S
-0.63 10 2A 132 22 16S
-0.52 17 2A 132 36 16S
-0.67 12 2A 132 38 16S
-0.69 14 2A 132 42 16S
-0.7 13 2A 132 48 15S 0.32 13 2A 132 65 15S
-0.09 19 2A 132 85 16S 0.34 12 2A 132 87 16S 0.35 12 2A 132 87 16S
-0.64 11 2A 132 88 16S
-0.11 30 2A 133 1
16S
-0.09 32 2A 133 1
14S
-0.5 18 2A 133 2
14S
-0.5 13 2A 133 4
16S
-0.16 14 2A 133 6
16S
-0.09 17 2A 133 8
15S 0.42 15 2A 133 9
16S
-0.61 11 2A 133 11 16S
-0.67 14 2A 133 13 16S
-0.52 11 2A 133 22 16S
-0.68 13 2A 133 22 13S 0.54 14 2A 133 23 16S
-0.59 15 2A 133 30 16S
-0.61 10 2A 133 35 16S
-0.64 20 2A 133 36 16S
-0.47 20 2A 133 40 16S
-0.64 13 2A 133 60 16S
-0.63 15 2A 133 61 15S
-0.54 16 2A 133 67 15S 0.39 15 2A 133 82 16S
-0.64 13 2A 133 83 16S
-0.5 14 2A 133 84 16S
-0.11 22 2A 133 86 16S
-0.09 29 2A 134 1
14S
-0.48 16 2A 134 1
16S
-0.09 14
Attachment L-22-211 Page 55 of 89 SG Row Tube TSP INCH
%TW 2A 134 2
16S 0.27 14 2A 134 3
16S 0.38 12 2A 134 7
16S
-0.49 10 2A 134 8
16S
-0.53 13 2A 134 15 15S 0.44 11 2A 134 22 15S 0.42 12 2A 134 23 16S
-0.59 12 2A 134 25 16S
-0.7 13 2A 134 33 16S
-0.78 17 2A 134 39 16S
-0.68 14 2A 134 50 15S 0.44 19 2A 134 77 16S 0.43 16 2A 134 84 16S
-0.09 17 2A 135 7
15S 0.46 10 2A 135 8
16S
-0.53 13 2A 135 10 16S
-0.52 11 2A 135 15 16S
-0.67 13 2A 135 19 14S
-0.5 20 2A 135 29 16S
-0.78 11 2A 135 35 14S
-0.54 11 2A 135 41 16S
-0.78 10 2A 135 69 16S
-0.59 19 2A 135 75 16S 0.42 13 2A 135 75 16S
-0.69 12 2A 135 77 16S
-0.14 19 2A 135 78 16S 0.45 11 2A 135 78 16S
-0.78 10 2A 135 80 16S
-0.62 12 2A 135 81 16S
-0.59 15 2A 135 82 16S
-0.09 20 2A 136 1
16S
-0.12 27 2A 136 1
14S
-0.5 26 2A 136 3
14S
-0.52 12 2A 136 9
15S 0.37 21 2A 136 10 15S 0.42 14 2A 136 15 15S
-0.54 16 2A 136 17 16S
-0.72 24 2A 136 18 16S
-0.61 12 2A 136 19 16S
-0.61 16 2A 136 21 16S
-0.66 11 2A 136 22 16S
-0.12 18 2A 136 22 15S
-0.09 23
Attachment L-22-211 Page 56 of 89 SG Row Tube TSP INCH
%TW 2A 136 28 16S
-0.71 11 2A 136 30 16S
-0.52 13 2A 136 31 16S
-0.5 15 2A 136 35 16S
-0.7 14 2A 136 48 15S 0.49 14 2A 136 52 15S
-0.61 11 2A 136 57 16S
-0.56 11 2A 136 59 15S 0.4 22 2A 136 77 16S
-0.81 12 2A 136 80 16S
-0.11 29 2A 137 5
16S
-0.65 12 2A 137 5
14S
-0.54 10 2A 137 11 15S 0.42 12 2A 137 14 16S
-0.65 13 2A 137 15 15S
-0.09 24 2A 137 16 16S
-0.59 16 2A 137 17 16S
-0.54 13 2A 137 20 16S
-0.64 14 2A 137 22 16S
-0.56 11 2A 137 31 16S
-0.68 12 2A 137 32 16S
-0.69 14 2A 137 37 16S
-0.73 13 2A 137 39 16S
-0.71 14 2A 137 53 15S
-0.64 11 2A 137 61 15S
-0.61 9
2A 137 69 16S 0.35 21 2A 137 76 16S
-0.22 21 2A 137 77 16S
-0.13 26 2A 138 1
14S
-0.5 11 2A 138 1
16S 0.36 11 2A 138 2
14S
-0.52 14 2A 138 8
16S
-0.56 14 2A 138 10 16S
-0.6 16 2A 138 13 16S
-0.67 14 2A 138 22 16S
-0.62 12 2A 138 26 16S
-0.55 21 2A 138 28 16S
-0.51 13 2A 138 28 15S
-0.58 7
2A 138 48 15S
-0.6 14 2A 138 61 15S
-0.59 9
2A 139 2
14S
-0.5 13 2A 139 3
14S
-0.5 10
Attachment L-22-211 Page 57 of 89 SG Row Tube TSP INCH
%TW 2A 139 4
16S
-0.63 14 2A 139 6
16S
-0.12 22 2A 139 7
14S
-0.55 11 2A 139 8
16S
-0.67 10 2A 139 9
15S 0.42 22 2A 139 10 16S
-0.6 16 2A 139 11 16S
-0.63 13 2A 139 12 16S
-0.68 12 2A 139 13 16S
-0.58 17 2A 139 14 16S
-0.56 16 2A 139 15 16S
-0.68 11 2A 139 17 16S
-0.68 11 2A 139 21 16S
-0.64 13 2A 139 22 16S
-0.64 14 2A 139 25 16S
-0.55 17 2A 139 31 16S
-0.78 13 2A 139 33 16S
-0.7 18 2A 139 37 16S
-0.69 17 2A 139 49 15S
-0.63 11 2A 139 54 15S 0.49 10 2A 139 63 15S
-0.54 8
2A 139 66 16S
-0.12 25 2A 139 67 16S 0.35 13 2A 139 67 16S
-0.56 12 2A 139 69 16S
-0.14 23 2A 139 70 16S 0.22 19 2A 139 70 16S
-0.57 24 2A 139 73 16S
-0.62 13 2A 140 2
16S 0.29 15 2A 140 2
14S
-0.5 11 2A 140 9
16S
-0.61 15 2A 140 10 14S
-0.52 10 2A 140 14 16S
-0.61 14 2A 140 18 16S
-0.68 12 2A 140 19 16S
-0.55 15 2A 140 20 16S
-0.7 13 2A 140 21 16S
-0.64 14 2A 140 27 16S
-0.57 10 2A 140 29 16S
-0.69 15 2A 140 30 16S
-0.7 13 2A 140 31 16S
-0.56 18 2A 140 32 16S
-0.59 19
Attachment L-22-211 Page 58 of 89 SG Row Tube TSP INCH
%TW 2A 140 35 16S
-0.77 12 2A 140 38 16S
-0.14 21 2A 140 38 15S
-0.09 18 2A 140 64 16S
-0.59 17 2A 140 66 16S
-0.61 14 2A 140 68 16S 0.39 16 2A 140 68 16S
-0.67 13 2A 140 70 16S
-0.12 39 2A 141 1
16S
-0.12 42 2A 141 1
14S
-0.41 26 2A 141 2
16S
-0.14 16 2A 141 5
14S
-0.52 11 2A 141 6
16S
-0.59 11 2A 141 7
16S
-0.61 12 2A 141 8
16S
-0.6 12 2A 141 9
16S
-0.12 18 2A 141 10 16S
-0.6 13 2A 141 11 16S
-0.67 13 2A 141 12 16S
-0.09 22 2A 141 12 15S 0.38 21 2A 141 13 15S
-0.09 26 2A 141 14 16S
-0.65 14 2A 141 15 16S
-0.76 12 2A 141 16 16S
-0.45 20 2A 141 16 14S
-0.5 13 2A 141 17 16S
-0.71 14 2A 141 19 16S
-0.52 16 2A 141 22 16S
-0.76 5
2A 141 25 16S
-0.71 19 2A 141 29 16S
-0.57 19 2A 141 30 16S
-0.5 19 2A 141 36 15S
-0.56 15 2A 141 39 16S
-0.69 13 2A 141 63 16S 0.28 13 2A 141 66 16S 0.27 18 2A 141 66 16S
-0.56 12 2A 141 67 16S 0.3 20 2A 141 67 16S
-0.55 18 2A 142 5
16S
-0.61 9
2A 142 10 15S 0.21 23 2A 142 11 15S 0.32 14 2A 142 12 14S
-0.52 15
Attachment L-22-211 Page 59 of 89 SG Row Tube TSP INCH
%TW 2A 142 13 16S
-0.59 21 2A 142 14 16S
-0.47 20 2A 142 14 15S 0.47 24 2A 142 18 16S
-0.73 11 2A 142 19 15S 0.25 21 2A 142 22 16S
-0.68 14 2A 142 24 16S
-0.64 14 2A 142 25 16S
-0.64 16 2A 142 26 16S
-0.77 13 2A 142 29 16S
-0.57 15 2A 142 38 15S
-0.59 11 2A 142 60 16S
-0.54 17 2A 142 62 16S 0.29 18 2A 142 62 16S
-0.61 12 2A 142 64 16S 0.38 18 2A 142 65 16S
-0.55 13 2A 143 2
16S
-0.12 23 2A 143 2
14S
-0.5 12 2A 143 6
16S
-0.12 17 2A 143 6
14S
-0.52 14 2A 143 8
16S
-0.59 14 2A 143 8
14S
-0.52 13 2A 143 9
16S
-0.55 21 2A 143 9
14S
-0.47 15 2A 143 11 16S
-0.59 21 2A 143 11 15S 0.54 17 2A 143 12 16S
-0.47 18 2A 143 13 16S
-0.52 19 2A 143 14 16S
-0.62 12 2A 143 14 15S 0.37 15 2A 143 17 16S
-0.73 11 2A 143 21 16S
-0.64 12 2A 143 22 16S
-0.69 11 2A 143 26 16S
-0.69 17 2A 143 31 16S
-0.47 14 2A 143 48 16S
-0.67 12 2A 143 52 16S
-0.65 11 2A 143 59 16S 0.33 15 2A 143 59 16S
-0.61 17 2A 143 60 16S 0.28 18 2A 143 61 16S 0.35 14 2A 143 61 16S
-0.61 18
Attachment L-22-211 Page 60 of 89 SG Row Tube TSP INCH
%TW 2A 144 1
16S
-0.12 30 2A 144 1
14S 0
35 2A 144 2
14S
-0.52 12 2A 144 4
14S
-0.52 17 2A 144 5
16S
-0.63 18 2A 144 5
14S
-0.54 14 2A 144 6
16S
-0.72 13 2A 144 9
16S
-0.6 14 2A 144 9
14S
-0.52 13 2A 144 11 15S 0.28 18 2A 144 12 15S
-0.07 26 2A 144 18 16S
-0.69 16 2A 144 19 16S
-0.62 10 2A 144 20 16S
-0.64 12 2A 144 20 15S 0.52 17 2A 144 20 14S
-0.56 10 2A 144 21 16S
-0.62 15 2A 144 22 16S
-0.64 16 2A 144 25 16S
-0.71 9
2A 144 28 16S
-0.65 11 2A 144 44 16S
-0.53 17 2A 144 46 16S
-0.12 21 2A 144 53 16S
-0.12 18 2A 144 54 16S 0.35 13 2A 144 56 16S
-0.09 24 2A 144 57 16S
-0.58 14 2A 145 1
16S
-0.14 27 2A 145 1
14S
-0.5 35 2A 145 2
14S
-0.54 29 2A 145 3
16S
-0.42 16 2A 145 3
14S
-0.5 18 2A 145 4
14S
-0.53 11 2A 145 4
16S
-0.56 16 2A 145 5
16S
-0.09 24 2A 145 5
14S
-0.56 11 2A 145 7
16S
-0.09 16 2A 145 7
14S
-0.55 14 2A 145 9
16S
-0.11 17 2A 145 10 16S
-0.11 17 2A 145 12 16S 0.27 13 2A 145 13 16S 0.32 11 2A 145 13 16S
-0.6 16
Attachment L-22-211 Page 61 of 89 SG Row Tube TSP INCH
%TW 2A 145 14 15S 0.39 23 2A 145 15 15S 0.45 21 2A 145 16 16S
-0.61 17 2A 145 16 14S
-0.52 12 2A 145 17 16S
-0.63 15 2A 145 18 15S 0.43 19 2A 145 19 16S
-0.12 19 2A 145 20 16S
-0.52 15 2A 145 21 16S
-0.5 16 2A 145 22 16S 0.38 13 2A 145 25 16S
-0.77 14 2A 145 31 16S
-0.67 11 2A 145 31 15S
-0.43 12 2A 145 37 16S
-0.58 13 2A 145 38 16S
-0.19 21 2A 145 41 16S
-0.55 14 2A 145 42 16S
-0.58 12 2A 145 44 16S
-0.09 16 2A 145 47 16S
-0.55 14 2A 145 49 16S
-0.56 19 2A 145 50 16S
-0.6 16 2A 145 51 16S
-0.12 19 2A 145 52 16S
-0.16 19 2A 146 1
16S
-0.58 11 2A 146 1
14S
-0.41 16 2A 146 2
14S
-0.51 34 2A 146 2
16S
-0.11 28 2A 146 3
14S
-0.57 14 2A 146 4
16S
-0.12 24 2A 146 5
14S
-0.52 14 2A 146 5
16S
-0.09 18 2A 146 7
16S
-0.12 21 2A 146 7
14S
-0.56 14 2A 146 9
14S
-0.48 11 2A 146 10 16S
-0.09 18 2A 146 12 16S
-0.71 12 2A 146 13 16S
-0.63 12 2A 146 14 16S
-0.61 12 2A 146 14 14S
-0.54 11 2A 146 15 16S
-0.49 23 2A 146 15 14S
-0.5 15 2A 146 16 16S
-0.69 11
Attachment L-22-211 Page 62 of 89 SG Row Tube TSP INCH
%TW 2A 146 17 16S
-0.54 13 2A 146 17 14S
-0.5 12 2A 146 20 16S
-0.02 19 2A 146 21 16S 0.4 8
2A 146 22 12S
-0.8 9
2A 146 22 16S
-0.25 15 2A 146 23 16S
-0.6 14 2A 146 24 15S 0.41 20 2A 146 28 15S
-0.46 9
2A 146 34 16S
-0.55 15 2A 146 35 16S
-0.6 15 2A 146 36 16S
-0.56 18 2A 146 38 16S
-0.55 16 2A 146 40 16S
-0.55 10 2A 146 41 16S
-0.11 14 2A 146 42 16S
-0.12 14 2A 146 47 16S
-0.53 17 2A 146 48 16S 0.36 11 2A 146 48 16S
-0.61 13 2A 147 1
16S
-0.63 15 2A 147 1
14S
-0.52 21 2A 147 2
16S
-0.09 27 2A 147 2
14S
-0.46 36 2A 147 3
14S
-0.54 15 2A 147 4
16S
-0.64 14 2A 147 4
14S
-0.54 13 2A 147 5
16S
-0.59 17 2A 147 5
14S
-0.5 13 2A 147 6
16S
-0.52 15 2A 147 7
16S
-0.64 15 2A 147 8
16S
-0.61 22 2A 147 9
16S
-0.53 19 2A 147 10 16S 0.43 12 2A 147 10 16S
-0.68 19 2A 147 11 16S 0.36 13 2A 147 12 16S
-0.74 16 2A 147 14 16S
-0.47 17 2A 147 15 16S
-0.55 14 2A 147 16 16S
-0.52 19 2A 147 17 16S
-0.66 16 2A 147 19 16S
-0.73 14 2A 147 20 16S
-0.64 17
Attachment L-22-211 Page 63 of 89 SG Row Tube TSP INCH
%TW 2A 147 20 15S 0.47 18 2A 147 22 16S
-0.64 11 2A 147 25 15S
-0.57 10 2A 147 32 16S
-0.44 20 2A 147 36 16S
-0.55 14 2A 147 40 16S
-0.53 18 2A 147 41 16S
-0.58 21 2A 147 42 16S 0.26 11 2A 147 42 16S
-0.54 15 2A 147 43 16S
-0.55 18 2A 147 45 16S 0.24 16 2A 147 45 16S
-0.54 22 2A 148 1
14S
-0.5 24 2A 148 3
14S
-0.54 28 2A 148 5
16S
-0.52 23 2A 148 5
14S
-0.49 9
2A 148 6
16S
-0.5 14 2A 148 7
16S
-0.67 14 2A 148 8
16S
-0.69 15 2A 148 10 16S 0.2 18 2A 148 11 16S
-0.47 19 2A 148 12 16S
-0.45 22 2A 148 13 16S
-0.64 19 2A 148 15 16S
-0.65 20 2A 148 20 16S
-0.73 11 2A 148 36 16S
-0.12 17 2A 148 37 16S
-0.53 17 2A 148 38 16S
-0.14 25 2A 148 39 16S
-0.54 16 2A 148 40 16S
-0.56 25 2A 149 1
14S
-0.05 30 2A 149 2
16S
-0.12 28 2A 149 2
14S
-0.61 14 2A 149 3
16S
-0.09 28 2A 149 3
14S
-0.55 23 2A 149 4
14S
-0.48 17 2A 149 5
16S
-0.58 23 2A 149 5
14S
-0.52 10 2A 149 7
16S
-0.61 20 2A 149 8
16S
-0.5 15 2A 149 9
16S
-0.49 22 2A 149 11 16S
-0.76 14
Attachment L-22-211 Page 64 of 89 SG Row Tube TSP INCH
%TW 2A 149 12 16S
-0.14 21 2A 149 13 16S
-0.12 16 2A 149 14 16S
-0.12 17 2A 149 15 16S
-0.11 22 2A 149 16 16S
-0.14 18 2A 149 17 16S
-0.14 21 2A 149 18 16S
-0.75 27 2A 149 19 16S
-0.6 20 2A 149 20 16S
-0.68 16 2A 149 24 16S 0.29 13 2A 149 26 16S 0.29 14 2A 149 33 16S
-0.51 18 2A 150 1
14S
-0.48 16 2A 150 2
16S
-0.67 19 2A 150 2
14S
-0.41 16 2A 150 3
16S
-0.14 32 2A 150 3
14S
-0.53 15 2A 150 4
16S
-0.12 31 2A 150 4
14S
-0.02 36 2A 150 6
14S
-0.02 30 2A 150 8
16S
-0.71 16 2A 150 9
16S
-0.55 17 2A 150 10 16S
-0.12 24 2A 150 11 16S
-0.16 26 2A 150 12 14S 0
32 2A 150 12 16S
-0.11 29 2A 150 13 16S
-0.12 28 2A 150 14 16S
-0.65 23 2A 150 16 16S 0.43 14 2A 150 17 16S
-0.12 27 2A 150 25 16S 0.26 11 2A 151 2
16S
-0.14 28 2A 151 2
14S
-0.02 42 2A 151 3
16S
-0.64 23 2A 151 4
16S
-0.16 30 2A 151 4
14S
-0.02 35 2A 151 5
16S
-0.14 16 2A 151 6
16S
-0.16 27 2A 151 6
14S
-0.5 11 2A 151 7
16S
-0.16 35 2A 151 8
16S
-0.14 26 2A 151 10 16S
-0.66 22
Attachment L-22-211 Page 65 of 89 SG Row Tube TSP INCH
%TW 2A 151 11 16S
-0.16 28 2A 151 12 16S
-0.12 15 2A 151 13 16S
-0.16 28 2A 151 14 16S
-0.16 19 1B 1
4 12S 0.57 13 1B 1
7 16S
-0.59 12 1B 1
8 16S
-0.61 12 1B 1
9 16S
-0.63 12 1B 1
12 14S 0.46 14 1B 1
13 14S 0.48 18 1B 1
16 16S
-0.11 20 1B 1
16 14S 0.5 11 1B 2
1 16S
-0.5 13 1B 2
10 12S 0.52 12 1B 2
24 01S
-0.27 14 1B 3
30 14S
-0.55 10 1B 3
34 16S
-0.09 29 1B 3
34 01S
-0.27 12 1B 4
1 16S
-0.61 16 1B 4
2 16S
-0.59 12 1B 4
2 16S 0.24 15 1B 4
19 16S
-0.61 12 1B 4
20 16S
-0.54 14 1B 4
41 16S
-0.09 31 1B 5
1 16S
-0.11 35 1B 5
27 15S
-0.05 15 1B 5
46 16S
-0.59 23 1B 6
1 16S
-0.55 27 1B 6
2 16S 0.35 16 1B 6
16 15S
-0.61 13 1B 6
35 15S 0.37 11 1B 7
1 16S
-0.12 17 1B 7
13 15S
-0.62 12 1B 8
1 16S
-0.53 19 1B 8
14 16S
-0.53 13 1B 8
28 16S
-0.56 13 1B 8
57 16S
-0.11 29 1B 9
1 16S
-0.11 28 1B 9
20 15S
-0.57 12 1B 9
29 15S
-0.59 13 1B 10 1
16S
-0.55 25 1B 10 4
16S
-0.57 16
Attachment L-22-211 Page 66 of 89 SG Row Tube TSP INCH
%TW 1B 10 9
16S
-0.73 13 1B 10 42 10S 0.61 10 1B 10 65 16S
-0.14 30 1B 11 1
16S
-0.13 35 1B 11 4
16S
-0.6 11 1B 11 12 16S
-0.53 13 1B 11 44 10S 0.64 11 1B 12 1
16S
-0.16 27 1B 12 8
16S 0.26 14 1B 12 13 16S
-0.5 12 1B 12 18 15S
-0.57 13 1B 12 71 16S 0.37 12 1B 13 6
16S
-0.12 17 1B 13 8
16S
-0.59 18 1B 13 15 16S
-0.74 10 1B 14 5
16S
-0.53 11 1B 14 20 15S
-0.55 12 1B 14 59 15S
-0.59 14 1B 14 74 16S 0.28 14 1B 14 75 16S
-0.09 23 1B 15 1
16S
-0.16 40 1B 15 11 16S
-0.76 13 1B 15 38 16S
-0.63 14 1B 15 59 15S
-0.61 14 1B 16 1
16S
-0.78 10 1B 16 52 15S
-0.59 14 1B 16 54 15S
-0.62 13 1B 16 80 13S 0.5 12 1B 16 81 01S 0.66 12 1B 17 10 15S
-0.57 11 1B 18 1
16S
-0.14 28 1B 18 3
16S 0.42 13 1B 18 8
16S
-0.71 11 1B 18 8
15S
-0.58 19 1B 18 28 15S
-0.54 12 1B 18 58 15S
-0.55 14 1B 18 73 16S
-0.6 18 1B 18 85 16S
-0.11 17 1B 19 1
16S
-0.7 21 1B 19 3
16S
-0.74 18 1B 19 6
16S 0.47 19 1B 19 9
16S 0.24 19
Attachment L-22-211 Page 67 of 89 SG Row Tube TSP INCH
%TW 1B 19 14 15S
-0.55 11 1B 19 56 15S
-0.66 13 1B 19 73 16S 0.39 13 1B 20 1
16S
-0.11 26 1B 20 4
16S 0.58 11 1B 20 13 16S
-0.78 12 1B 20 23 16S
-0.58 11 1B 20 26 16S
-0.61 10 1B 20 62 15S
-0.59 13 1B 20 77 15S 0.44 11 1B 21 1
16S
-0.8 17 1B 21 2
16S
-0.68 12 1B 21 3
16S
-0.68 11 1B 21 4
16S
-0.79 19 1B 21 8
16S 0.41 11 1B 21 8
16S
-0.72 11 1B 21 9
16S
-0.76 10 1B 21 10 16S
-0.74 11 1B 21 13 16S
-0.72 15 1B 21 16 16S
-0.62 14 1B 21 51 15S
-0.68 11 1B 21 52 15S
-0.61 10 1B 21 63 15S
-0.55 10 1B 21 90 16S
-0.09 21 1B 22 1
16S
-0.14 30 1B 22 9
16S 0.44 14 1B 22 15 16S
-0.62 12 1B 23 1
16S
-0.13 14 1B 23 5
16S 0.44 11 1B 23 6
16S
-0.14 14 1B 23 7
16S
-0.74 15 1B 23 69 16S
-0.55 16 1B 23 73 15S
-0.59 13 1B 24 5
16S 0.35 15 1B 24 6
16S
-0.72 15 1B 24 8
16S
-0.75 13 1B 24 14 16S
-0.8 13 1B 24 50 15S
-0.61 12 1B 24 53 15S
-0.65 11 1B 24 88 15S 0.46 12 1B 25 7
16S
-0.71 11 1B 25 25 16S
-0.81 12
Attachment L-22-211 Page 68 of 89 SG Row Tube TSP INCH
%TW 1B 25 73 15S
-0.57 11 1B 25 81 15S
-0.6 10 1B 26 4
16S
-0.67 13 1B 26 73 15S
-0.61 11 1B 27 1
16S
-0.18 26 1B 27 2
16S
-0.82 14 1B 27 35 16S
-0.66 11 1B 27 71 16S
-0.54 13 1B 27 80 15S
-0.62 12 1B 27 81 15S
-0.55 12 1B 27 91 15S
-0.64 14 1B 28 3
16S
-0.71 24 1B 28 7
16S
-0.82 15 1B 28 56 15S
-0.57 13 1B 28 57 16S
-0.53 14 1B 29 1
16S
-0.13 26 1B 29 9
16S
-0.68 14 1B 29 54 15S
-0.55 11 1B 29 58 16S
-0.66 10 1B 29 62 16S
-0.6 13 1B 29 63 16S
-0.59 10 1B 29 104 01S
-0.37 11 1B 30 3
16S
-0.77 18 1B 30 8
16S
-0.77 18 1B 30 9
16S
-0.7 16 1B 30 29 14S
-0.57 14 1B 30 63 16S
-0.57 13 1B 30 74 16S
-0.63 12 1B 30 99 16S 0.41 12 1B 30 101 16S 0.34 12 1B 31 3
16S
-0.73 12 1B 32 5
16S
-0.8 12 1B 32 14 16S
-0.81 10 1B 32 61 16S
-0.59 10 1B 32 69 16S
-0.59 14 1B 32 71 15S
-0.5 13 1B 33 73 15S
-0.66 12 1B 34 1
16S
-0.14 33 1B 34 47 16S
-0.66 8
1B 34 98 15S
-0.64 15 1B 35 3
16S
-0.68 11 1B 35 35 16S
-0.68 13
Attachment L-22-211 Page 69 of 89 SG Row Tube TSP INCH
%TW 1B 35 76 15S
-0.64 12 1B 35 77 15S
-0.55 11 1B 35 93 15S
-0.62 16 1B 36 5
16S
-0.79 15 1B 36 8
15S
-0.55 11 1B 36 16 15S 0.02 13 1B 36 37 16S
-0.72 12 1B 36 82 15S
-0.64 12 1B 36 95 16S 0.33 13 1B 36 96 16S
-0.76 13 1B 37 1
16S
-0.68 19 1B 37 2
16S
-0.74 11 1B 37 89 16S
-0.58 12 1B 37 95 16S 0.31 11 1B 37 114 11S 0.52 12 1B 38 1
16S
-0.7 11 1B 38 4
16S
-0.74 11 1B 38 7
16S
-0.75 12 1B 38 76 15S
-0.6 13 1B 38 86 15S
-0.62 14 1B 38 104 16S
-0.55 17 1B 38 106 16S
-0.56 13 1B 38 113 16S
-0.51 14 1B 39 5
16S
-0.64 11 1B 39 10 16S
-0.79 11 1B 39 11 16S
-0.75 15 1B 39 88 16S 0.33 10 1B 39 98 15S
-0.66 11 1B 39 116 16S 0
17 1B 40 4
16S
-0.61 14 1B 40 5
16S
-0.76 12 1B 40 101 16S
-0.55 13 1B 40 112 15S
-0.64 14 1B 40 113 16S 0.33 12 1B 40 114 16S
-0.53 15 1B 40 117 16S
-0.09 27 1B 41 3
16S
-0.63 10 1B 41 33 16S
-0.68 13 1B 41 59 16S
-0.56 13 1B 41 80 15S
-0.64 10 1B 41 82 15S
-0.59 10 1B 41 102 16S
-0.58 13
Attachment L-22-211 Page 70 of 89 SG Row Tube TSP INCH
%TW 1B 41 115 16S 0.26 12 1B 42 1
16S
-0.68 12 1B 42 2
16S
-0.63 12 1B 42 3
16S
-0.74 9
1B 42 5
16S
-0.61 11 1B 42 8
16S
-0.75 12 1B 42 10 16S 0.33 11 1B 42 99 16S
-0.53 13 1B 42 104 16S
-0.58 10 1B 42 104 15S
-0.64 12 1B 42 107 16S
-0.02 16 1B 43 1
16S
-0.66 14 1B 43 91 16S
-0.58 16 1B 43 104 16S 0.3 11 1B 44 1
16S
-0.12 23 1B 44 2
16S
-0.66 10 1B 44 13 16S
-0.7 13 1B 44 85 16S
-0.57 13 1B 44 91 16S
-0.53 17 1B 44 101 16S 0.35 10 1B 44 119 11S 0.43 13 1B 45 1
16S
-0.14 19 1B 45 4
16S
-0.63 10 1B 45 56 15S
-0.66 9
1B 45 99 16S
-0.58 14 1B 46 1
16S
-0.09 16 1B 46 3
16S
-0.72 11 1B 46 4
16S
-0.59 12 1B 46 12 16S
-0.74 12 1B 46 90 16S
-0.61 14 1B 46 99 16S 0.28 11 1B 46 113 16S 0.35 14 1B 46 114 15S
-0.71 15 1B 46 115 15S
-0.64 14 1B 47 1
16S
-0.5 21 1B 47 2
16S
-0.73 12 1B 48 3
16S
-0.53 14 1B 48 6
16S
-0.71 17 1B 48 9
16S
-0.12 20 1B 48 10 16S 0.33 15 1B 48 14 16S
-0.8 19 1B 48 107 16S
-0.56 13
Attachment L-22-211 Page 71 of 89 SG Row Tube TSP INCH
%TW 1B 48 123 16S
-0.09 22 1B 49 7
15S
-0.6 10 1B 49 8
16S
-0.63 13 1B 49 10 16S
-0.67 18 1B 49 18 16S
-0.83 11 1B 49 124 16S
-0.09 26 1B 50 1
11S 0.46 10 1B 50 2
16S
-0.55 12 1B 50 4
16S
-0.51 11 1B 50 11 16S
-0.77 10 1B 50 24 16S
-0.82 13 1B 50 117 15S
-0.64 19 1B 51 1
11S 0.58 13 1B 51 3
16S
-0.54 12 1B 51 23 16S
-0.77 12 1B 52 2
16S 0.3 10 1B 52 9
16S
-0.66 12 1B 52 11 16S
-0.65 10 1B 52 12 16S
-0.73 9
1B 52 96 16S
-0.63 12 1B 52 115 15S
-0.64 11 1B 53 1
16S
-0.57 13 1B 53 9
16S
-0.7 11 1B 53 98 16S
-0.62 12 1B 53 115 16S
-0.74 13 1B 53 119 16S
-0.65 13 1B 53 119 15S 0.42 14 1B 53 126 16S
-0.12 21 1B 54 2
16S
-0.55 10 1B 54 8
15S
-0.58 11 1B 54 25 13S
-0.57 9
1B 54 120 15S 0.53 13 1B 54 127 16S
-0.57 10 1B 55 3
16S
-0.57 11 1B 55 10 16S
-0.69 10 1B 55 120 15S 0.59 13 1B 55 120 15S
-0.66 10 1B 55 121 15S 0.48 12 1B 55 121 15S
-0.64 12 1B 56 92 16S
-0.67 12 1B 56 96 16S
-0.68 14 1B 56 122 15S 0.53 16
Attachment L-22-211 Page 72 of 89 SG Row Tube TSP INCH
%TW 1B 56 123 15S 0.51 19 1B 56 124 15S 0.51 13 1B 57 1
16S
-0.59 17 1B 57 7
16S
-0.7 12 1B 57 11 16S
-0.67 10 1B 57 99 16S
-0.6 13 1B 57 119 15S
-0.59 8
1B 57 125 15S
-0.59 13 1B 57 128 16S
-0.09 29 1B 58 1
11S 0.07 12 1B 58 2
16S
-0.61 12 1B 58 15 16S
-0.74 16 1B 58 121 15S
-0.62 9
1B 58 129 16S
-0.09 27 1B 59 1
16S
-0.56 17 1B 59 2
16S
-0.56 12 1B 59 121 15S
-0.61 12 1B 60 98 16S
-0.62 14 1B 60 109 15S
-0.64 11 1B 60 121 15S
-0.64 10 1B 60 129 16S
-0.07 20 1B 61 2
16S
-0.54 10 1B 61 3
16S
-0.67 12 1B 61 126 16S 0.44 13 1B 61 130 16S
-0.65 19 1B 62 1
16S
-0.56 21 1B 62 5
16S
-0.54 15 1B 62 9
16S
-0.61 13 1B 62 105 16S
-0.62 14 1B 62 123 16S
-0.65 12 1B 62 125 16S
-0.67 11 1B 62 126 16S
-0.63 11 1B 62 129 16S 0.44 15 1B 63 1
16S
-0.54 18 1B 63 12 16S
-0.74 15 1B 63 120 16S 0.26 13 1B 63 130 16S
-0.09 28 1B 63 130 13S 0.02 21 1B 64 127 16S
-0.73 11 1B 64 128 16S 0.37 11 1B 64 130 16S 0.4 17 1B 64 131 16S
-0.09 27
Attachment L-22-211 Page 73 of 89 SG Row Tube TSP INCH
%TW 1B 64 131 14S
-0.46 19 1B 65 3
16S
-0.62 18 1B 65 9
15S
-0.59 11 1B 65 123 16S
-0.68 13 1B 65 129 16S 0.44 11 1B 65 130 16S 0.44 15 1B 65 130 14S 0.48 11 1B 65 130 13S 0.44 15 1B 66 2
16S
-0.55 11 1B 66 3
16S
-0.57 16 1B 66 4
16S
-0.66 16 1B 66 5
16S
-0.54 15 1B 66 6
16S
-0.54 17 1B 66 7
16S
-0.72 15 1B 66 18 16S
-0.76 11 1B 66 128 16S 0.37 13 1B 66 128 16S
-0.59 14 1B 66 130 16S
-0.09 22 1B 66 131 16S
-0.14 23 1B 66 131 13S
-0.37 9
1B 66 131 14S
-0.09 16 1B 67 2
16S
-0.51 12 1B 67 13 16S
-0.77 16 1B 67 15 16S
-0.78 12 1B 67 120 16S
-0.63 12 1B 67 126 16S 0.27 15 1B 67 129 16S 0.46 13 1B 68 1
16S
-0.54 27 1B 68 2
16S
-0.56 15 1B 68 4
16S
-0.65 14 1B 68 6
16S
-0.59 12 1B 68 12 16S
-0.65 16 1B 68 117 16S
-0.62 18 1B 68 122 16S
-0.64 12 1B 68 127 15S
-0.71 12 1B 68 129 15S 0.5 16 1B 68 131 16S
-0.11 30 1B 68 131 13S 0.05 23 1B 68 131 11S 0.5 12 1B 68 131 14S 0.05 20 1B 69 4
15S 0.55 13 1B 69 14 16S
-0.75 12
Attachment L-22-211 Page 74 of 89 SG Row Tube TSP INCH
%TW 1B 69 19 16S
-0.76 10 1B 69 105 16S
-0.69 12 1B 69 126 15S 0.43 13 1B 69 126 15S
-0.52 11 1B 69 131 13S 0.46 13 1B 70 1
16S
-0.56 15 1B 70 2
16S
-0.56 15 1B 70 5
16S
-0.54 13 1B 70 6
16S
-0.59 12 1B 70 7
15S
-0.53 11 1B 70 17 16S
-0.92 10 1B 70 19 16S
-0.78 10 1B 70 111 16S
-0.66 11 1B 70 122 16S
-0.63 10 1B 70 129 16S
-0.73 11 1B 71 9
16S
-0.68 15 1B 71 17 15S
-0.62 13 1B 71 20 16S
-0.76 13 1B 71 117 16S
-0.76 12 1B 71 118 16S
-0.68 11 1B 71 126 16S
-0.73 13 1B 71 127 16S
-0.68 11 1B 72 1
16S
-0.61 12 1B 72 2
16S 0.33 12 1B 72 3
15S 0.57 13 1B 72 4
16S
-0.64 13 1B 72 6
16S
-0.57 14 1B 72 11 16S
-0.77 15 1B 72 14 16S
-0.72 12 1B 72 115 16S
-0.64 10 1B 72 116 16S
-0.59 11 1B 72 120 16S 0.4 10 1B 72 126 16S
-0.73 13 1B 72 128 16S 0.36 13 1B 72 131 16S
-0.09 20 1B 73 3
16S
-0.64 19 1B 73 3
15S
-0.09 19 1B 73 4
16S
-0.67 15 1B 73 5
16S
-0.57 16 1B 73 10 16S 0.33 12 1B 73 12 16S
-0.72 10 1B 73 13 16S
-0.74 11
Attachment L-22-211 Page 75 of 89 SG Row Tube TSP INCH
%TW 1B 73 120 16S
-0.62 11 1B 73 122 16S
-0.75 9
1B 73 125 16S
-0.64 13 1B 73 127 16S
-0.66 15 1B 73 129 16S 0.37 11 1B 73 131 16S
-0.71 12 1B 73 131 11S 0.6 26 1B 73 132 16S
-0.11 33 1B 74 1
16S
-0.56 23 1B 74 2
16S
-0.51 17 1B 74 3
16S
-0.57 20 1B 74 3
15S 0.54 14 1B 74 3
15S
-0.63 14 1B 74 6
16S
-0.52 15 1B 74 11 16S
-0.65 10 1B 74 14 16S
-0.77 15 1B 74 15 16S
-0.76 10 1B 74 19 16S
-0.82 10 1B 74 107 16S
-0.6 11 1B 74 130 16S
-0.14 18 1B 74 130 14S 0.5 11 1B 74 131 16S
-0.07 15 1B 74 131 11S 0.57 12 1B 74 131 14S 0
15 1B 74 131 13S 0
13 1B 75 1
16S
-0.56 11 1B 75 1
12S
-0.41 9
1B 75 2
16S
-0.56 24 1B 75 5
16S
-0.59 19 1B 75 6
15S
-0.63 12 1B 75 8
16S
-0.78 14 1B 75 11 16S
-0.7 12 1B 75 14 16S
-0.75 10 1B 75 15 16S
-0.72 11 1B 75 105 16S
-0.62 12 1B 75 120 16S
-0.61 10 1B 75 123 16S
-0.76 11 1B 75 124 16S
-0.56 12 1B 75 130 16S
-0.53 15 1B 75 130 14S 0.48 13 1B 75 130 13S 0.43 14 1B 75 131 16S
-0.71 15
Attachment L-22-211 Page 76 of 89 SG Row Tube TSP INCH
%TW 1B 75 131 14S 0.48 14 1B 75 131 11S 0.55 16 1B 75 132 16S
-0.57 14 1B 75 132 14S
-0.46 15 1B 76 1
16S 0.22 27 1B 76 1
16S
-0.54 11 1B 76 1
11S
-0.46 15 1B 76 2
16S 0.26 24 1B 76 18 16S
-0.75 8
1B 76 20 16S
-0.71 15 1B 76 115 16S
-0.69 8
1B 76 116 14S
-0.02 14 1B 76 122 16S
-0.63 14 1B 76 123 16S
-0.67 14 1B 76 127 16S
-0.76 16 1B 76 129 16S
-0.07 16 1B 76 130 16S
-0.71 17 1B 76 131 16S
-0.52 10 1B 76 131 11S 0.55 14 1B 77 1
11S 0.11 23 1B 77 2
11S 0.71 11 1B 77 4
16S
-0.62 11 1B 77 5
16S
-0.54 12 1B 77 21 16S
-0.82 12 1B 77 104 15S
-0.59 13 1B 77 109 15S
-0.14 17 1B 77 120 16S
-0.71 11 1B 77 132 16S
-0.57 11 1B 77 132 14S
-0.34 9
1B 77 132 13S
-0.02 18 1B 78 1
16S
-0.11 14 1B 78 1
11S 0.67 19 1B 78 10 16S 0.39 12 1B 78 123 16S
-0.71 9
1B 78 127 16S
-0.55 14 1B 78 129 16S
-0.6 14 1B 78 130 16S
-0.52 13 1B 79 1
11S 0.57 22 1B 79 3
16S
-0.69 17 1B 79 5
16S
-0.54 14 1B 79 7
16S
-0.72 12 1B 79 116 14S 0.46 13
Attachment L-22-211 Page 77 of 89 SG Row Tube TSP INCH
%TW 1B 79 132 13S
-0.34 10 1B 80 1
16S
-0.09 18 1B 80 1
11S 0.62 13 1B 80 3
16S 0.37 11 1B 80 5
16S
-0.57 8
1B 80 124 16S
-0.55 11 1B 80 127 16S
-0.64 14 1B 80 128 16S
-0.64 10 1B 81 1
16S
-0.09 30 1B 81 2
16S
-0.12 16 1B 81 3
16S 0.39 12 1B 81 122 16S
-0.6 16 1B 81 126 16S
-0.62 13 1B 81 132 16S
-0.14 19 1B 82 1
16S 0.28 14 1B 82 1
11S 0.62 16 1B 82 2
16S
-0.57 9
1B 82 3
16S 0.42 14 1B 82 115 16S
-0.57 14 1B 82 123 16S
-0.73 10 1B 82 131 11S 0.59 10 1B 83 1
11S 0.59 13 1B 83 1
16S 0.33 12 1B 83 2
16S
-0.58 12 1B 83 2
11S 0.64 13 1B 83 5
16S 0.28 13 1B 83 113 16S
-0.6 10 1B 83 119 16S
-0.6 10 1B 83 120 16S
-0.53 12 1B 83 121 15S
-0.57 13 1B 83 122 16S
-0.66 12 1B 83 128 16S
-0.62 13 1B 84 1
11S 0.74 19 1B 84 1
16S
-0.12 23 1B 84 3
16S
-0.6 11 1B 84 5
16S
-0.54 10 1B 84 7
16S
-0.78 10 1B 84 125 16S
-0.62 13 1B 84 128 16S
-0.62 9
1B 85 1
16S 0.35 12 1B 85 123 16S
-0.57 10 1B 86 5
16S
-0.12 22
Attachment L-22-211 Page 78 of 89 SG Row Tube TSP INCH
%TW 1B 86 7
16S
-0.77 12 1B 86 9
16S
-0.7 10 1B 86 16 16S
-0.63 9
1B 86 131 16S
-0.57 11 1B 87 1
16S 0.24 14 1B 87 1
11S 0.54 11 1B 87 116 16S
-0.59 12 1B 88 1
16S
-0.05 21 1B 88 5
16S
-0.57 9
1B 88 7
16S
-0.7 10 1B 88 119 16S
-0.55 11 1B 88 126 16S
-0.69 10 1B 88 131 16S
-0.62 17 1B 88 131 14S
-0.39 8
1B 88 131 13S
-0.32 14 1B 89 1
16S
-0.59 10 1B 89 79 12S
-0.64 8
1B 89 130 16S
-0.11 21 1B 90 123 16S
-0.66 13 1B 91 1
16S
-0.14 17 1B 91 2
16S
-0.57 10 1B 91 130 14S 0.52 10 1B 92 1
16S
-0.12 18 1B 92 4
16S
-0.71 10 1B 92 8
16S
-0.72 13 1B 92 120 16S
-0.69 7
1B 92 124 16S
-0.57 14 1B 92 129 14S 0.5 14 1B 93 4
16S
-0.73 11 1B 93 93 15S
-0.69 8
1B 93 114 16S
-0.66 12 1B 94 1
16S
-0.12 28 1B 94 129 14S 0.48 14 1B 95 1
16S
-0.09 31 1B 95 4
13S
-0.46 10 1B 95 101 15S
-0.64 13 1B 95 113 14S 0.34 19 1B 95 117 16S
-0.64 13 1B 97 5
15S 0.5 10 1B 97 92 15S 0.35 12 1B 97 120 16S
-0.55 12 1B 97 123 16S
-0.5 14
Attachment L-22-211 Page 79 of 89 SG Row Tube TSP INCH
%TW 1B 98 107 15S
-0.57 11 1B 99 1
16S
-0.14 19 1B 99 4
16S
-0.57 8
1B 99 8
16S 0.45 10 1B 100 1
16S
-0.12 18 1B 100 4
16S
-0.5 10 1B 100 6
16S
-0.64 11 1B 100 104 15S
-0.46 14 1B 101 1
16S
-0.14 24 1B 101 1
01S 0.64 11 1B 101 116 16S
-0.6 9
1B 102 1
16S
-0.75 11 1B 103 2
16S
-0.56 11 1B 103 12 16S
-0.63 11 1B 103 99 16S
-0.58 11 1B 103 109 16S
-0.71 11 1B 104 1
16S
-0.72 14 1B 104 98 14S 0.45 13 1B 105 1
16S
-0.14 22 1B 105 13 16S
-0.65 10 1B 105 112 16S
-0.59 12 1B 106 1
16S 0.5 15 1B 106 95 14S 0.46 16 1B 106 103 16S
-0.52 13 1B 107 1
16S
-0.12 24 1B 107 85 15S
-0.62 11 1B 107 114 16S
-0.59 12 1B 108 1
16S
-0.12 22 1B 108 9
16S
-0.7 14 1B 108 98 16S
-0.55 11 1B 109 4
15S 0.42 15 1B 109 10 16S
-0.7 10 1B 109 81 16S
-0.61 10 1B 109 95 15S
-0.64 7
1B 109 97 15S
-0.62 14 1B 112 1
16S
-0.09 20 1B 112 4
16S 0.37 11 1B 112 8
16S 0.54 10 1B 113 20 16S
-0.82 12 1B 113 21 16S
-0.79 9
1B 113 73 16S
-0.59 12 1B 113 76 16S
-0.63 10
Attachment L-22-211 Page 80 of 89 SG Row Tube TSP INCH
%TW 1B 113 82 16S
-0.6 11 1B 113 91 16S
-0.82 10 1B 113 103 16S
-0.57 9
1B 114 1
16S
-0.74 10 1B 114 2
16S
-0.74 9
1B 114 19 16S
-0.74 12 1B 114 104 16S
-0.69 12 1B 115 1
16S
-0.12 19 1B 115 5
16S
-0.71 11 1B 115 6
16S
-0.69 11 1B 115 85 16S
-0.62 9
1B 115 86 16S
-0.58 13 1B 115 104 16S
-0.62 10 1B 116 13 16S
-0.82 11 1B 116 88 16S
-0.58 11 1B 116 91 15S
-0.64 12 1B 116 104 16S
-0.63 10 1B 116 113 16S
-0.39 17 1B 117 80 16S
-0.6 13 1B 117 89 16S
-0.59 11 1B 118 1
16S
-0.6 12 1B 118 6
16S
-0.74 11 1B 118 7
16S
-0.73 15 1B 118 29 16S
-0.55 11 1B 118 74 16S 0.33 11 1B 118 76 14S 0.48 14 1B 118 103 16S
-0.55 9
1B 118 108 14S
-0.5 11 1B 119 14 16S
-0.89 10 1B 120 1
16S
-0.14 17 1B 120 78 16S
-0.57 9
1B 120 107 14S 0
21 1B 121 1
16S
-0.72 11 1B 121 63 16S
-0.6 13 1B 121 64 16S
-0.65 12 1B 121 67 16S
-0.57 9
1B 121 85 14S
-0.57 13 1B 121 88 16S
-0.54 13 1B 121 91 16S
-0.58 12 1B 121 97 14S 0.34 18 1B 121 106 13S
-0.42 9
1B 121 106 14S 0.05 15
Attachment L-22-211 Page 81 of 89 SG Row Tube TSP INCH
%TW 1B 122 1
11S 0.64 9
1B 122 9
16S
-0.74 13 1B 122 62 16S
-0.66 14 1B 122 70 16S
-0.53 10 1B 122 73 14S 0.46 15 1B 122 85 16S
-0.59 14 1B 122 105 16S
-0.07 26 1B 123 67 16S
-0.57 11 1B 123 70 16S
-0.6 15 1B 123 73 16S 0.26 14 1B 123 74 16S
-0.57 12 1B 123 75 16S
-0.55 10 1B 123 80 16S
-0.52 14 1B 123 85 16S
-0.59 13 1B 123 91 16S
-0.61 16 1B 123 104 16S
-0.07 28 1B 123 104 01S 0.16 13 1B 124 78 16S
-0.64 13 1B 124 91 16S
-0.59 12 1B 124 94 15S
-0.48 9
1B 125 1
16S
-0.69 17 1B 125 17 16S
-0.81 15 1B 125 71 16S
-0.57 9
1B 125 86 16S
-0.59 14 1B 126 9
16S
-0.69 11 1B 126 70 16S
-0.57 11 1B 126 73 16S
-0.57 12 1B 126 77 16S
-0.64 11 1B 126 78 16S
-0.52 13 1B 126 79 16S
-0.54 12 1B 126 86 16S
-0.54 14 1B 126 90 16S
-0.57 13 1B 126 91 16S
-0.57 15 1B 126 94 16S
-0.67 15 1B 126 99 16S
-0.07 21 1B 127 60 16S
-0.6 8
1B 127 61 16S
-0.6 10 1B 127 70 16S
-0.53 11 1B 127 71 16S
-0.57 13 1B 127 81 16S
-0.56 10 1B 127 85 16S
-0.57 12 1B 127 87 16S
-0.56 14
Attachment L-22-211 Page 82 of 89 SG Row Tube TSP INCH
%TW 1B 127 88 16S
-0.58 16 1B 127 89 16S
-0.59 12 1B 128 60 16S
-0.6 11 1B 128 72 16S
-0.55 13 1B 128 87 16S
-0.54 14 1B 129 1
16S
-0.14 18 1B 129 61 16S
-0.57 10 1B 129 73 16S
-0.52 13 1B 129 76 16S
-0.54 17 1B 129 78 16S
-0.54 16 1B 129 79 16S
-0.54 12 1B 129 83 16S 0.24 11 1B 129 88 16S
-0.57 13 1B 130 57 16S
-0.6 11 1B 130 64 16S
-0.55 12 1B 130 73 16S
-0.54 12 1B 130 74 16S
-0.54 17 1B 130 82 16S
-0.56 12 1B 131 49 15S
-0.78 8
1B 131 51 15S
-0.62 13 1B 131 53 16S
-0.6 11 1B 131 61 16S
-0.55 10 1B 131 69 16S
-0.56 11 1B 131 77 16S
-0.52 16 1B 131 84 16S
-0.56 18 1B 132 1
16S
-0.14 24 1B 132 18 16S
-0.81 11 1B 132 19 16S 0.48 11 1B 132 49 16S
-0.75 10 1B 132 51 16S
-0.62 10 1B 132 58 16S
-0.57 11 1B 132 59 16S
-0.62 12 1B 132 67 16S
-0.58 13 1B 132 73 16S
-0.59 10 1B 132 79 16S
-0.07 15 1B 132 83 16S
-0.58 16 1B 132 89 16S
-0.55 25 1B 133 2
16S 0.47 11 1B 133 56 16S
-0.57 11 1B 133 60 16S
-0.6 12 1B 133 70 16S
-0.56 15 1B 133 78 16S
-0.54 16
Attachment L-22-211 Page 83 of 89 SG Row Tube TSP INCH
%TW 1B 133 80 16S
-0.12 16 1B 134 1
16S
-0.16 27 1B 134 7
16S
-0.11 17 1B 134 44 16S
-0.66 8
1B 134 51 16S
-0.55 12 1B 134 54 16S
-0.64 10 1B 134 55 16S
-0.6 10 1B 134 62 16S
-0.55 14 1B 134 68 16S
-0.16 15 1B 135 7
15S
-0.69 11 1B 135 42 16S
-0.66 8
1B 135 43 16S
-0.69 10 1B 135 53 16S
-0.57 11 1B 135 55 16S
-0.55 10 1B 135 60 16S
-0.56 11 1B 135 61 16S
-0.56 13 1B 135 75 16S
-0.56 17 1B 135 76 16S
-0.54 19 1B 135 77 11S
-0.67 10 1B 136 22 16S
-0.53 11 1B 136 41 16S
-0.75 11 1B 136 42 16S
-0.76 13 1B 136 47 15S
-0.55 12 1B 136 50 16S
-0.62 15 1B 136 53 16S
-0.57 12 1B 136 54 16S
-0.58 11 1B 136 62 16S
-0.55 12 1B 136 65 15S
-0.62 14 1B 137 1
16S
-0.07 15 1B 137 45 16S
-0.73 11 1B 137 70 15S
-0.05 18 1B 137 73 16S
-0.52 12 1B 138 1
16S 0.4 12 1B 138 15 16S 0.39 12 1B 138 43 16S
-0.73 10 1B 138 57 16S
-0.59 11 1B 139 2
16S 0.45 16 1B 139 36 16S
-0.65 12 1B 139 41 16S
-0.67 10 1B 139 45 16S
-0.67 11 1B 139 46 16S
-0.67 11 1B 139 51 16S
-0.57 11
Attachment L-22-211 Page 84 of 89 SG Row Tube TSP INCH
%TW 1B 139 54 16S
-0.6 13 1B 139 57 16S
-0.53 15 1B 139 66 16S
-0.52 10 1B 139 69 16S
-0.56 11 1B 139 70 16S
-0.56 10 1B 140 1
16S
-0.87 11 1B 140 16 15S 0.39 15 1B 140 59 16S 0.28 13 1B 140 66 16S
-0.56 10 1B 140 69 16S
-0.55 14 1B 140 70 13S
-0.53 9
1B 140 70 12S 0.57 12 1B 141 1
16S
-0.16 36 1B 141 4
16S 0.57 9
1B 141 7
16S 0.33 15 1B 141 37 16S
-0.71 10 1B 141 39 16S
-0.75 9
1B 141 45 16S
-0.67 12 1B 141 46 16S
-0.57 10 1B 141 52 16S
-0.57 10 1B 141 53 16S
-0.56 16 1B 141 57 16S
-0.53 11 1B 141 58 16S
-0.56 11 1B 141 60 16S
-0.59 11 1B 141 68 16S
-0.52 13 1B 142 1
16S
-0.73 9
1B 142 43 16S
-0.67 14 1B 142 55 16S
-0.54 11 1B 143 32 16S
-0.69 15 1B 143 35 16S
-0.77 12 1B 143 37 16S
-0.6 14 1B 143 39 16S
-0.67 13 1B 143 49 16S
-0.58 14 1B 143 51 16S
-0.55 15 1B 143 52 16S
-0.55 13 1B 143 58 16S
-0.54 16 1B 143 60 16S 0.37 10 1B 144 19 15S 0.49 13 1B 144 31 16S
-0.73 20 1B 144 35 16S
-0.58 15 1B 144 37 16S
-0.69 11 1B 145 29 16S 0.37 13
Attachment L-22-211 Page 85 of 89 SG Row Tube TSP INCH
%TW 1B 145 32 16S
-0.69 15 1B 145 34 15S 0.48 12 1B 145 34 15S
-0.51 13 1B 145 40 16S
-0.65 13 1B 145 42 16S 0.33 12 1B 145 44 16S
-0.11 20 1B 145 48 16S
-0.43 12 1B 145 48 10S 0.52 11 1B 146 32 15S 0.44 16 1B 146 51 01S
-0.16 15 1B 147 29 16S
-0.74 11 1B 147 33 16S
-0.65 14 1B 148 28 16S
-0.6 15 1B 148 39 16S 0.35 19 1B 148 40 16S
-0.09 19 1B 149 24 16S
-0.57 14 1B 149 27 16S
-0.6 16 1B 149 29 16S
-0.59 11 1B 149 30 16S
-0.6 11 1B 149 32 11S
-0.32 11 1B 149 32 16S
-0.11 14 1B 150 18 16S
-0.63 9
1B 150 23 16S 0.28 25 1B 150 23 16S
-0.6 11 1B 150 24 16S 0.23 27 1B 151 6
16S
-0.63 8
1B 151 10 16S
-0.14 19 1B 151 11 16S
-0.58 27 1B 151 12 16S
-0.12 19 1B 151 13 16S 0.4 18 1B 151 13 01S
-0.14 12 1B 151 14 16S 0.42 25 1B 151 14 16S
-0.71 22
Attachment L-22-211 Page 86 of 89 Wear at Drilled TSPs SG Row Tube TSP Max Depth
[%TW]
Axial Extent
[in]
Circumferential Extent [°]
PDA*
[%]
2A 36 1
15S 19 0.31 51.3 2.71 2A 113 4
15S 22 0.31 166.8 10.19 2A 147 12 15S 20 0.36 64.2 3.57 2A 148 20 15S 15 0.27 102.7 4.28 1B 29 1
15S 19 0.38 89.8 4.74 1B 37 114 15S 19 0.29 141.2 7.45 1B 38 115 15S 21 0.29 115.5 6.74 1B 40 117 15S 23 0.31 102.7 6.56 1B 48 123 15S 27 0.29 102.7 7.70
- The PDA is conservatively determined as the maximum depth over the entire circumferential extent.
Attachment L-22-211 Page 87 of 89 Section 5 Number of Tubes Plugged During the Inspection Outage for Each Degradation Mechanism (TS 5.6.6.e)
Degradation Mechanism SG 2A SG 1B Wear at broached TSP 14 1
Attachment L-22-211 Page 88 of 89 Section 6 The Number and Percentage of Tubes Plugged to Date, and the Effective Plugging Percentage in Each SG (TS 5.6.6.f)
SG 2A SG 1B Total Tubes Plugged 135 82 217 Percentage Plugged 0.87%
0.53%
0.70%
Attachment L-22-211 Page 89 of 89 Section 7 The Results of Condition Monitoring, Including the Results of Tube Pulls and In-Situ Testing (TS 5.6.6.g)
No degradation was identified that failed to meet condition monitoring criteria. All steam generator performance criteria were met analytically during Cycle 22. As such, in-situ pressure testing was not required, and none was performed. No tube pulls were planned, and none were performed.