ML21089A209

From kanterella
Jump to navigation Jump to search
Spent Fuel Pattern Procedure
ML21089A209
Person / Time
Site: Duane Arnold NextEra Energy icon.png
Issue date: 03/19/2021
From: Marlone Davis
NextEra Energy Duane Arnold
To: Marlayna Vaaler Doell
Reactor Decommissioning Branch
Doell M
Shared Package
ML21089A207 List:
References
Download: ML21089A209 (1)


Text

From:

Davis, J.Michael To:

Doell, Marlayna

Subject:

[External_Sender] Fuel Pool pattern Date:

Friday, March 19, 2021 8:34:38 AM Attachments:

image001.png ACP 1208.57_018.pdf

Marlayna, In answer to your question on how we arrange fuel bundles in the fuel pool, see attached and excerpt below. Let me know if this answers your question.

Mike

We use a checkerboard pattern - freshly discharged assemblies must not be face adjacent to each other. Additionally, we cannot place freshly discharge assemblies in rack leg support locations.

Freshly discharge assemblies is defined as assemblies having less than one year of decay time.

From Section 4.4.9 of ACP 1208.57:

Mike Davis Licensing Manager NextEra Energy Duane Arnold 319-851-7032 J.Michael.Davis@nee.com