WBL-21-006, Refueling Outage 3 Generic Letter 95-05 Voltage-Based Alternate Repair Criteria Final Report
| ML21042B342 | |
| Person / Time | |
|---|---|
| Site: | Watts Bar |
| Issue date: | 02/11/2021 |
| From: | Anthony Williams Tennessee Valley Authority |
| To: | Document Control Desk, Office of Nuclear Reactor Regulation |
| References | |
| WBL-21-006 | |
| Download: ML21042B342 (87) | |
Text
1\\14 TENNESSEE VALLEY AUTHORITY Post Office Box 2000, Spring City, Tennessee 37381 WBL-21 -006 February 11, 2021 ATTN: Document Control Desk U.S. Nuclear Regulatory Commission Washington, D.C. 20555-0001 Watts Bar Nuclear Plant, Unit 2 Facility Operating License No. NPF-96 NRC Docket No. 50-391 10 CFR 50.4
Subject:
Watts Bar Nuclear Plant (WBN) Unit 2 - Refueling Outage 3 Generic Letter 95-05 Voltage-Based Alternate Repair Criteria Final Report In accordance with the requirements of WBN Technical Specification (TS) 5.9.9, "Steam Generator Tube Inspection Report", the Enclosure provides the 90 Day Steam Generator Inspection Report for Unit 2 Cycle 2. This report is required to be submitted within 90 days after the initial entry into MODE 4 following the completion of an inspection performed in accordance with TS 5.7.2.12, "Steam Generator (SG) Program" when voltage-based alternate repair criteria have been applied.
There are no regulatory commitments contained in this letter. Please direct any questions concerning this matter to Tony Brown, WBN Licensing Manager, at (423) 365-7720.
Anthony L. Williams IV Site Vice President Watts Bar Nuclear Plant
U.S. Nuclear Regulatory Commission WBL-21 -006 Page 2 February 11, 2021
Enclosure:
Watts Bar Unit 2 Refueling Outage 3 Generic Letter 95-05 Voltage-Based Alternate Repair Criteria Final Report cc (Enclosure):
NRC Regional Administrator - Region II NRC Senior Resident Inspector - Watts Bar Nuclear Plant NRC Project Manager - Watts Bar Nuclear Plant
ENCLOSURE Tennessee Valley Authority Watts Bar Nuclear Plant Unit 2 Watts Bar Unit 2 Refueling Outage 3 Generic Letter 95-05 Voltage-Based Alternate Repair Criteria Final Report
WESTINGHOUSE NON-PROPRIETARY CLASS 3 SG-CDMP-21-1-NP February 2021 Revision 0 Watts Bar Unit 2 Refueling Outage 3 Generic Letter 95-05 Voltage-Based Alternate Repair Criteria Final Report
- This record was final approved on 2/10/2021 3:23:04 PM. (This statement was added by the PRIME system upon its validation)
- This record was final approved on 2/10/2021 3:23:04 PM. (This statement was added by the PRIME system upon its validation)
WESTINGHOUSE NON-PROPRIETARY CIASS 3 SG-CDMP-21-1-NP Revision 0 Watts Bar Unit 2 Refueling Outage 3 Generic Letter 95-05 Voltage-Based Alternate Repair Criteria Final Report Author's Name:
Levi Y. Marcus Prepared for:
Tennessee Valley Authority Signature / Date
- Electronically Approved Component Design & Management Programs Verifier's Name:
Bradley T. Carpenter Component Design & Management Programs Manager Name:
Michael E. Bradley, Manager Component Design & Management Programs Reviewer's Name:
Jeremy W. Mayo TV A SG Corporate Program Manager Reviewer's Name:
Jesse S. Baron TV A SG Corporate Program Engineer Signature / Date
- Electronically Approved Signature I Date
- Electronically Approved Signature / Date Dlgltllly signed by M1yo, Jeremy Mayo, Jeremy Wayne w1yne Date: 2021.02.09 16:53:19 -05'00' Signature / Date
!""' ~. ~
l I
- Electronicallyapproved records are authenticated in the Electronic Document Management System.
SG-CDMP-21-1-NP Westinghouse Electric Company ILC P.O.Box 158 Madison,PA 15663
© 2021 Westinghouse Flectric Company ILC All Rights Reserved February 2021 Revision0
WESTINGHOUSE NON-PROPRIETARY CLASS 3 ii SG-CDMP-21-1-NP February 2021 Revision 0 RECORD OF REVISIONS Revision Date Description 0
See EDMS Original
- This record was final approved on 2/10/2021 3:23:04 PM. (This statement was added by the PRIME system upon its validation)
WESTINGHOUSE NON-PROPRIETARY CLASS 3 iii SG-CDMP-21-1-NP February 2021 Revision 0 TABLE OF CONTENTS RECORD OF REVISIONS............................................................................................................ ii TABLE OF CONTENTS............................................................................................................... iii LIST OF TABLES......................................................................................................................... iv LIST OF FIGURES.........................................................................................................................v 1
INTRODUCTION............................................................................................................ 1-1 2
SUMMARY
AND CONCLUSIONS................................................................................ 2-1 3
U2R3 INSPECTION RESULTS AND VOLTAGE GROWTH RATES............................ 3-1 3.1 U2R3 Inspection Results............................................................................................ 3-1 3.2 Voltage Growth Rates................................................................................................. 3-3 3.3 Probe Wear Criteria..................................................................................................... 3-3 3.4 NDE Uncertainties...................................................................................................... 3-3 4
DATABASE APPLIED FOR LEAK AND BURST CORRELATIONS........................... 4-1 4.1 Tube Material Properties............................................................................................ 4-1 4.2 Burst Correlation......................................................................................................... 4-1 4.3 Leak Rate Correlation................................................................................................. 4-1 4.4 Probability of Leak Correlation.................................................................................. 4-1 4.5 NDE Uncertainties...................................................................................................... 4-1 5
SLB ANALYSIS METHODS........................................................................................... 5-1 6
BOBBIN VOLTAGE DISTRIBUTIONS......................................................................... 6-1 6.1 Calculation of Voltage Distributions.......................................................................... 6-1 6.2 Probability of Detection (POD).................................................................................. 6-1 6.3 Limiting Growth Rate Distribution............................................................................ 6-2 6.4 Cycle Operating Period.............................................................................................. 6-2 6.5 Projected EOC-4a Voltage Distribution..................................................................... 6-3 7
SLB LEAK RATE AND TUBE BURST PROBABILITY ANALYSES........................... 7-1 7.1 U2R3 Condition Monitoring Leak Rate and Tube Burst Probability....................... 7-1 7.2 EOC-4a Operational Assessment Leak Rate and Tube Burst Probability............... 7-1 8
REFERENCES................................................................................................................. 8-1 APPENDIX A............................................................................................................................. A-1
- This record was final approved on 2/10/2021 3:23:04 PM. (This statement was added by the PRIME system upon its validation)
WESTINGHOUSE NON-PROPRIETARY CLASS 3 iv SG-CDMP-21-1-NP February 2021 Revision 0 LIST OF TABLES Table 3-1 U2R3 DSI Result Summary........................................................................................ 3-2 Table 3-2 U2R3 DSI/DSV Voltage Distribution for SG-1.......................................................... 3-4 Table 3-3 U2R3 DSI/DSV Voltage Distribution for SG-2.......................................................... 3-5 Table 3-4 U2R3 DSI/DSV Voltage Distribution for SG-3.......................................................... 3-6 Table 3-5 U2R3 DSI/DSV Voltage Distribution for SG-4.......................................................... 3-7 Table 3-6 SG-1 U2R3 Indication Distribution as Function of Tube Support Plate.................... 3-8 Table 3-7 SG-2 U2R3 Indication Distribution as Function of Tube Support Plate.................... 3-9 Table 3-8 SG-3 U2R3 Indication Distribution as Function of Tube Support Plate.................. 3-10 Table 3-9 SG-4 U2R3 Indication Distribution as Function of Tube Support Plate.................. 3-11 Table 3-10 U2R3 Indication Distribution as Function of Tube Support Plate,......................... 3-12 Table 3-11 SG-1 Voltage Growth Cumulative Distribution...................................................... 3-12 Table 3-12 SG-2 Voltage Growth Cumulative Distribution...................................................... 3-13 Table 3-13 SG-3 Voltage Growth Cumulative Distribution...................................................... 3-14 Table 3-14 SG-4 Voltage Growth Cumulative Distribution...................................................... 3-15 Table 3-15 Voltage Growth Cumulative Distribution, All SGs................................................. 3-16 Table 3-16 Indications with Largest Growth in Cycle 3........................................................... 3-17 Table 6-1 Predicted Voltage Distribution.................................................................................... 6-4 Table 7-1 Condition Monitoring Leak and Burst Results for U2R3........................................... 7-2 Table 7-2 Operational Assessment Leak and Burst Results for EOC-4a.................................... 7-2 Table A-1 SG-1 U2R3 DSI Indications..................................................................................... A-1 Table A-2 SG-2 U2R3 DSI Indications..................................................................................... A-7 Table A-3 SG-3 U2R3 DSI Indications................................................................................... A-15 Table A-4 SG-4 U2R3 DSI Indications................................................................................... A-26
- This record was final approved on 2/10/2021 3:23:04 PM. (This statement was added by the PRIME system upon its validation)
WESTINGHOUSE NON-PROPRIETARY CLASS 3 v
SG-CDMP-21-1-NP February 2021 Revision 0 LIST OF FIGURES Figure 3-1 Voltage Distribution in SG-1............................................................................. 3-18 Figure 3-2 Voltage Distribution in SG-2............................................................................. 3-18 Figure 3-3 Voltage Distribution in SG-3............................................................................. 3-19 Figure 3-4 Voltage Distribution in SG-4............................................................................. 3-19 Figure 3-5 Indication Distribution by TSP.......................................................................... 3-20 Figure 3-6 Voltage Growth during Cycle 3......................................................................... 3-21 Figure 3-7 Upper 5% of Voltage Growth during Cycle 3.................................................... 3-22 Figure 3-8 Cycle 3 Voltage Growth vs. BOC Voltage......................................................... 3-23 Figure 6-1 SG-1 Voltage Distributions.................................................................................. 6-8 Figure 6-2 SG-2 Voltage Distributions.................................................................................. 6-9 Figure 6-3 SG-3 Voltage Distributions................................................................................ 6-10 Figure 6-4 SG-4 Voltage Distributions................................................................................ 6-11
- This record was final approved on 2/10/2021 3:23:04 PM. (This statement was added by the PRIME system upon its validation)
WESTINGHOUSE NON-PROPRIETARY CLASS 3 1-1 SG-CDMP-21-1-NP February 2021 Revision 0 1
INTRODUCTION This report provides a summary of the Watts Bar Unit 2 steam generator (SG) bobbin and
+POINT'1 probe inspections at tube support plate (TSP) intersections from the Fall 2020, U2R3 outage, together with postulated Steam Line Break (SLB) leak rate and tube burst probability analyses. The U2R3 outage represents the first application of the Generic Letter (GL) 95-05 (Reference 1) voltage-based repair criteria, and implementation of its requirements, to the Watts Bar Unit 2 SGs. Information required by the GL 95-05 and by WBN Technical Specification 5.9.9 is provided in this report, including steam line break (SLB) leak rates and tube burst probabilities calculated using the end-of-cycle (EOC) conditions for the recently completed Cycle 3, representing a Condition Monitoring (CM) assessment of bobbin coil signal amplitudes for observed possible indications. In addition, a projection of EOC-4a bobbin coil voltage distributions, as well as the associated SG tube leak rates and burst probabilities through EOC-4a conditions, is provided. An itemized list of the TS reporting requirements and location of the information within this report is contained in Section 2. The evaluation is performed for a partial duration of Cycle 4 because the conditional probability of burst would not be satisfied for an entire cycle due to the flaw population observed during U2R3, particularly in SG-3. This will require a mid-cycle inspection to be performed in Cycle 4, which is referred to as U2R4a in this report. The SG inspection to occur during the fourth refueling outage for Watts Bar 2 is referred to as U2R4b in this report.
The condition monitoring analysis at EOC-3 was carried out using the actual bobbin coil voltage distributions measured during the U2R3 outage. These results show that the U2R3 condition monitoring leak rates and conditional burst probabilities for all four SGs are within their respective allowable limits with the exception of conditional probability of burst for SG-3. This calculated value exceeds the acceptance criteria value of 1 x 10-2 and a subsequent notification to the Nuclear Regulatory Commission (NRC) was made (Reference 14). These evaluations were performed according to the methodology of WCAP-14277 (Reference 3).
The Operational Assessment (OA) analysis was performed to project leak rates and tube burst probabilities for postulated SLB conditions at the end of the next inspection interval (EOC-4a). These analyses utilized bobbin voltage distributions measured during the recent (U2R3) inspection and a growth rate distribution bounding the last two inspections (U2R2 and U2R3), with U2R2 bobbin measurements determined from lookbacks to U2R2 data. Leak and burst analyses for the operational assessment were performed using the Reference 4 primary-to-secondary pressure differential of 2405 psi, which credits power-operated relief valve (PORV) actuation.
1 +POINT is a trademark or registered trademark of Zetec, Inc. Other names may be trademarks of their respective owners.
- This record was final approved on 2/10/2021 3:23:04 PM. (This statement was added by the PRIME system upon its validation)
WESTINGHOUSE NON-PROPRIETARY CLASS 3 2-1 SG-CDMP-21-1-NP February 2021 Revision 0 2
SUMMARY
AND CONCLUSIONS A total of 1240 distorted support indications (DSI and DSV) in all four SGs combined were reported during the Watts Bar Unit 2 (WB2) U2R3 bobbin coil inspection. Per GL 95-05, only those DSI and DSV signals with a bobbin coil signal amplitude of 1.0 volts (lower repair limit) or greater are required to be inspected using a +POINT (or equivalent) probe. However, all indications with bobbin voltage between 0.75V and 1.0V were tested with the +POINT probe to generate data for confirmation rate of bobbin indications. Tubes with indications measured at 1.0V or greater and confirmed by +POINT probe were plugged. Tubes with indications measured at 2.85V or greater (upper repair limit for indications at TSP locations) by bobbin were plugged. Only one indication at a FDB location was found to exceed the upper repair limit for indications at FDB locations of 1.82V, and the tube was also plugged. A total of 199 DSI indications were removed from service by plugging. The maximum bobbin coil voltage indication in all SGs was 9.35 volts on R17 C54 at the flow distribution baffle (FDB) in SG-3.
WBN Technical Specification 5.9.9 specifies that the GL 95-05 90-day report shall include information described in Section 6.b of Attachment 1 to GL 95-05. This information is contained within this report in the location noted next to each item in the table below. No tubes were pulled during U2R3 for metallurgical examination associated with GL 95-05 Item 6.b(a).
- This record was final approved on 2/10/2021 3:23:04 PM. (This statement was added by the PRIME system upon its validation)
WESTINGHOUSE NON-PROPRIETARY CLASS 3 2-2 SG-CDMP-21-1-NP February 2021 Revision 0 GL Attachment 1, 6.b Item Location (a) Metallurgical Examination Results N/A (b)(i) EOC Voltage Distribution EOC-3:
Table 3-2, Table 3-3, Table 3-4, Table 3-5 Figure 3-1, Figure 3-2, Figure 3-3, Figure 3-4 EOC-4a:
Table 6-1 Figure 6-1, Figure 6-2, Figure 6-3, Figure 6-4 (b)(ii) Cycle Voltage Growth Rate Distribution Table 3-11, Table 3-12, Table 3-13, Table 3-14, Table 3-15 Figure 3-6, Figure 3-7 (b)(iii) Voltage Distribution for EOC Repaired Indications Table 3-2, Table 3-3, Table 3-4, Table 3-5 (b)(iv) Voltage Distribution for Indications Returned to Service Table 3-2, Table 3-3, Table 3-4, Table 3-5 (b)(v) Voltage Distribution for Indications Returned to Service Confirmed by RPC or not RPC Inspected Table 3-2, Table 3-3, Table 3-4, Table 3-5 (b)(vi) NDE Examination Uncertainty Distribution Used in Predicting the EOC Voltage Distribution Section 3.4 (c) Tube Integrity Evaluation Results Section 7 Table 7-1, Table 7-2 SLB leak rate and tube burst probability analyses were performed using the actual U2R3 bobbin voltage distributions (condition monitoring analysis) as well as the projected EOC-4a bobbin
- This record was final approved on 2/10/2021 3:23:04 PM. (This statement was added by the PRIME system upon its validation)
WESTINGHOUSE NON-PROPRIETARY CLASS 3 2-3 SG-CDMP-21-1-NP February 2021 Revision 0 voltage distributions (operational assessment). The SLB leak rates from the condition monitoring analysis meet the faulted SG allowable limit of 3.0 gpm (room temperature), Reference 11. The corresponding condition monitoring tube burst probability values are below the allowable limit of 1.0 x 10-2, with the exception of SG-3 which exceeds the conditional probability of burst limit.
This conclusion was reported to the NRC during U2R3 (Reference 14).
At U2R3, the largest SLB leak rate in the condition monitoring analysis is calculated for SG-3, with a magnitude of 1.09 gpm, which is below the allowable SLB leakage limit of 3.0 gpm in the faulted SG. All leak rate values quoted are equivalent volumetric rates at room temperature. The limiting conditional tube burst probability from the condition monitoring analysis, 3.005 x 10-2 calculated for SG-3, exceeds the NRC reporting guideline of 1.0 x 10-2. The condition monitoring results for all other SGs are within the allowable limit.
The operational assessment for Cycle 4 was performed for 285 calendar days which was determined to be the maximum operating time for the conditional probability of burst criteria to be satisfied for SG-3. The operational assessment utilized DSI growth which credited lookback to bobbin data from U2R2 for the DSIs detected during U2R3. SLB leak rate and tube burst probability projections at the EOC-4a conditions were performed using the latest alternate repair criteria (ARC) database available for 3/4-inch outside diameter (OD) tubing which is documented in Reference 4. Leak and burst analyses for the Cycle 4 operational assessment were performed using the Reference 4 primary-to-secondary pressure differential of 2405 psi, which credits PORV actuation. SG-3 is predicted to be the limiting SG for leakage and probability of burst. For a projected Cycle 4a duration of 285 calendar days, the EOC-4a leak rate projected for SG-3, when applying the NRC approved alternate POD discussed in Section 6.2, is 0.479 gpm (at room temperature), which is less than the current limit of 3.0 gpm in the faulted SG. This leak rate projection utilized the leak rate calculation methodology of References 5 and 6. The limiting EOC-4a burst probability of 9.812 x 10-3 is calculated for SG-3 and is below the allowable limit of 1.0 x 10-2. Therefore, all acceptance criteria of Reference 1 will be satisfied throughout for 285 calendar days of operation.
- This record was final approved on 2/10/2021 3:23:04 PM. (This statement was added by the PRIME system upon its validation)
WESTINGHOUSE NON-PROPRIETARY CLASS 3 3-1 SG-CDMP-21-1-NP February 2021 Revision 0 3
U2R3 INSPECTION RESULTS AND VOLTAGE GROWTH RATES 3.1 U2R3 Inspection Results U2R3 is the first refueling outage for which the alternate repair criterion per GL 95-05 have been approved and implemented for Watts Bar Unit 2. In accordance with the guidance provided by GL 95-05, the U2R3 inspection of the Watts Bar Unit 2 SGs consisted of a 100% eddy current (EC) bobbin probe full length examination of the tube bundles in all four SGs.
Tube-to-TSP intersections where the tubes with degradation may potentially collapse or deform as a result of the combined postulated loss-of-coolant accident (LOCA) and safe shutdown earthquake loadings were excluded from the ARC per Reference 7. The EOC-3 eddy current inspection plan included 100% +POINT probe inspection of all hot leg and cold leg dents >2 volts (as measured from the bobbin probe), which exceeds the requirement that the GL 95-05 ARC does not apply to intersections with dents greater than 5 volts. The EOC-3 eddy current inspection plan included 100% +POINT inspection of TSP mix residual signals that could cause a 1.0-volt bobbin signal to be missed or misread, as required by GL 95-05. There were no intersections identified with copper deposits which could interfere with the signal. Therefore, the requirements of the GL 95-05 methodology in Section 1.b of Reference 1 are satisfied.
All DSI indications which matched or exceeded the lower repair limit of 1.0 volt were subject to
+POINT inspection in accordance with GL 95-05 (Reference 1). All DSI indications which exceeded the upper voltage repair limit of 2.85 volts at tube-TSP intersections and 1.82 volts at FDB intersections were plugged. The upper voltage repair criteria applied to the tube-to-TSP intersections and tube-to-FDB intersections are in accordance with Sections 2.a.2 and 2.a.3 of Reference 1, respectively.
The three-letter code for DSI indications which exceeded the upper voltage repair limit was reported as DSV instead of DSI. For the purpose of this report, the three-letter code DSI also includes indications which exceed the upper voltage repair limit and therefore includes those indications which were reported during U2R3 with the three-letter code DSV. DSI indications detected on tubes excluded from application of GL 95-05, as documented in Reference 7, were reported as DSE during the U2R3 inspections. DSE indications are not included in the GL 95-05 assessment and those indications are addressed through standard SG tube integrity assessments.
Table 3-1 provides a summary of the number of DSI indications reported in U2R3 which were less than the lower voltage repair limit, greater than the lower voltage repair limit but less than the upper voltage repair limit, and greater than the upper voltage repair limit for each SG.
- This record was final approved on 2/10/2021 3:23:04 PM. (This statement was added by the PRIME system upon its validation)
WESTINGHOUSE NON-PROPRIETARY CLASS 3 3-2 SG-CDMP-21-1-NP February 2021 Revision 0 Table 3-1 U2R3 DSI Result Summary SG-1 SG-2 SG-3 SG-4 Total 0 Volts < 1.0V 182 278 301 291 1052 1.0 Volts < 2.85V 18 35 89 34 176 2.85 Volts 0
1 10 1
12 Total DSIs 200 314 400 326 1240 Table 3-2, Table 3-3, Table 3-4, and Table 3-5 present the U2R3 bobbin DSI voltage data for the TSP intersections in the four SGs. A total of 1240 DSI indications at TSP locations were detected in all four SGs combined, of which 176 indications had voltage amplitudes greater than 1.0 volt and less than the upper voltage repair limit. A total of 12 indications exceeded the upper voltage repair limit. For the analyses, the DSI indications are binned in 0.1-volt intervals where the numeric value of the bin represents the upper range of the bin. For example, the 1.0-volt bin contains DSI voltages from 0.91 to 1.00 volt. For U2R3, all DSIs with a voltage amplitude greater than or equal to 0.75 volts were tested using the +POINT probe which exceeds the GL 95-05 requirement to RPC test indications that exceed the lower repair limit by bobbin coil.
There a total of 289 new DSI indications confirmed by +POINT probe in U2R3. The indications were confirmed as Single Axial Indication (SAI) or Multiple Axial Indications (MAI) after analyst review of the RPC data.
- 21 SAIs and 3 MAIs in SG-1
- 41 SAIs and 8 MAIs in SG-2
- 75 SAIs and 80 MAIs in SG-3
- 60 SAIs and 1 MAI in SG-4 Table 3-2, Table 3-3, Table 3-4 and Table 3-5 tabulate the number of field bobbin indications, the number of those indications that were +POINT probe rotating pancake coil (RPC) inspected, the number of +POINT probe RPC confirmed indications, the number of indications removed from service, and the number of indications returned to service. The distribution of U2R3 indications is also shown in Figure 3-1, Figure 3-2, Figure 3-3, and Figure 3-4 for SG-1, SG-2, SG-3, and SG-4, respectively.
The distribution of U2R3 indications as a function of support plate location is summarized in Table 3-6, Table 3-7, Table 3-8, Table 3-9 and Table 3-10 and shown in Figure 3-5. This includes the average Cycle 3 growth for each support plate location (calculated with negative growth set to
- 0) and the total average growth for each generator (calculated with negative growth values). The data indicates that the lower hot leg TSPs have the most ODSCC indications, reducing with TSP elevation after either the first or second TSP. The highest TSP elevation with an RPC confirmed DSI was H06 in SG4 at one location. There were virtually no DSIs reported at the FDB with the exception of 3 reported indications in SG-3. Only 18 indications were detected on the cold leg side; only one of these exceeded 1.0 volt and this location was NDF by +POINT exam. This distribution is consistent with that observed at other plants and is commonly attributed to the temperature dependence of outside diameter stress corrosion cracking (ODSCC).
- This record was final approved on 2/10/2021 3:23:04 PM. (This statement was added by the PRIME system upon its validation)
WESTINGHOUSE NON-PROPRIETARY CLASS 3 3-3 SG-CDMP-21-1-NP February 2021 Revision 0 Appendix A provides a listing of all DSIs and voltages reported at the WBN U2R3 outage in Table A-1, Table A-2, Table A-3, and Table A-4, and includes whether axial ODSCC was confirmed as an SAI or MAI, whether the tube containing the indication(s) was plugged, and whether the indication was tested and no defect was found.
3.2 Voltage Growth Rates For projection of leak rates and tube burst probabilities at EOC-3, voltage growth rates were developed from the U2R2 and U2R3 inspection bobbin data. Growth is determined when the same indication can be identified in two successive inspections. For the U2R3 preliminary GL 95-05 OA evaluation, there were a total of 155 growth data points used for all four SGs combined. In order to ensure that sufficient and accurate point-to-point growth values were used in the growth projections in this report, the U2R2 historical data was reviewed for all locations where DSIs and DSVs were reported in U2R3, resulting in a point-to-point growth value for each DSI reported at U2R3. Table 3-6, Table 3-7, Table 3-8, Table 3-9, and Table 3-10 show the largest and average DSI voltage growth for each TSP in each SG, and for each TSP in all SGs combined. Table 3-11, Table 3-12, Table 3-13, and Table 3-14, and Table 3-15 show the frequency and cumulative probability distribution of growth as a function of voltage change in each WB2 steam generator during Cycle 3.
Table 3-16 lists the top 23 indications based on the Cycle 3 growth rate in descending order.
The Cycle 3 voltage growth distributions for each SG are shown in Figure 3-5 and Figure 3-6.
From the figure, it is understood that SG-3 growth was the highest of the four generators. Figure 3-7 provides a magnified view of the upper 5% tail of the growth curves for all four SGs.
To determine if WB2 growth rates exhibited a potential dependency on the beginning of cycle (BOC) voltage, the growth rate data for Cycle 3 was plotted against BOC voltage, and the resulting plot is shown in Figure 3-8. It should be noted that growth data exceeding 5V is not displayed in the figure in order to better display the majority of the data. There were a total of 4 indications with growth exceeding 5V and all had BOC voltages of 0.26V or less. The Cycle 3 growth data, based on bobbin lookups from U2R2, do not show any tendency to increase with the BOC voltage; if at all, the growth seems to decrease with increasing BOC voltage. Therefore, for the purposes of this evaluation, growth can be assumed independent of voltage in the Monte Carlo analysis for the operational assessment.
3.3 Probe Wear Criteria The probe wear criterion approved by the NRC (Reference 8) was applied during the U2R3 inspection. When a probe does not pass the 15% wear limit, this alternate criterion requires that only tubes with indications above 75% of the repair limit inspected since the last successful probe wear check be re-inspected with a good probe. As the lower repair limit for Watts Bar Unit 2 is 1.00 volts, all tubes containing indications for which the worn probe voltage is above 0.75 volts are to be inspected with a new probe.
3.4 NDE Uncertainties The NDE uncertainties applied for the Cycle 3 voltage distributions in the Monte Carlo analyses for leak rate and burst probabilities are the same as those in the NRC Generic Letter 95-05 (Reference 1).
The probe wear uncertainty has a standard deviation of 7.0% about a mean of zero and has a cut-off at 15% based on implementation of the probe wear standard. If the random sample of probe wear
- This record was final approved on 2/10/2021 3:23:04 PM. (This statement was added by the PRIME system upon its validation)
WESTINGHOUSE NON-PROPRIETARY CLASS 3 3-4 SG-CDMP-21-1-NP February 2021 Revision 0 selected during the Monte Carlo simulations exceeds 15%, sampling of the probe wear distribution is continued until a value less than 15% is picked. The analyst variability uncertainty has a standard deviation of 10.3% about a mean of zero with no cut-off. These nondestructive examination (NDE) uncertainty distributions are included in the Monte Carlo analyses for SLB leak rates and tube burst probabilities based on the U2R3 actual voltage distributions as well as for the EOC-4a projections.
Table 3-2 U2R3 DSI/DSV Voltage Distribution for SG-1 Voltage Bin Number of Indications
+POINT Probe Confirmed
+POINT Probe Tested But Not Confirmed Not +POINT Probe Tested Plugged Returned to Service 0.2 1
0 0
1 0
1 0.3 15 1
1 13 0
15 0.4 29 2
2 25 0
29 0.5 35 2
2 31 0
35 0.6 26 1
1 24 1
25 0.7 31 1
4 26 0
31 0.8 22 4
13 5
2 20 0.9 13 5
8 0
0 13 1
10 5
5 0
0 10 1.1 4
0 4
0 0
4 1.2 7
1 6
0 2
5 1.3 4
1 3
0 1
3 1.4 2
0 2
0 0
2 1.7 1
1 0
0 1
0 Total 200 24 51 125 7
193 Average voltage = 0.620 volt
- This record was final approved on 2/10/2021 3:23:04 PM. (This statement was added by the PRIME system upon its validation)
WESTINGHOUSE NON-PROPRIETARY CLASS 3 3-5 SG-CDMP-21-1-NP February 2021 Revision 0 Table 3-3 U2R3 DSI/DSV Voltage Distribution for SG-2 Voltage Bin Number of Indications
+POINT Probe Confirmed
+POINT Probe Tested But Not Confirmed Not +POINT Probe Tested Plugged Returned to Service 0.2 7
0 0
7 0
7 0.3 23 2
3 18 0
23 0.4 43 3
6 34 1
42 0.5 52 2
13 37 0
52 0.6 43 4
7 32 1
42 0.7 37 2
4 31 0
37 0.8 29 8
9 12 1
28 0.9 27 7
20 0
1 26 1
19 4
15 0
1 18 1.1 7
3 4
0 3
4 1.2 5
2 3
0 2
3 1.3 7
2 5
0 2
5 1.4 5
2 3
0 2
3 1.5 3
3 0
0 3
0 1.6 1
1 0
0 1
0 1.7 2
1 1
0 1
1 1.8 1
1 0
0 1
0 1.9 1
0 1
0 0
1 2.1 1
1 0
0 1
0 3.9 1
1 0
0 1
0 Total 314 49 94 171 22 292 Average voltage = 0.651 volt
- This record was final approved on 2/10/2021 3:23:04 PM. (This statement was added by the PRIME system upon its validation)
WESTINGHOUSE NON-PROPRIETARY CLASS 3 3-6 SG-CDMP-21-1-NP February 2021 Revision 0 Table 3-4 U2R3 DSI/DSV Voltage Distribution for SG-3 Voltage Bin Number of Indications
+POINT Probe Confirmed
+POINT Probe Tested But Not Confirmed Not +POINT Probe Tested Plugged Returned to Service 0.2 2
1 0
1 1
1 0.3 12 3
1 8
2 10 0.4 30 2
3 25 4
26 0.5 49 5
4 40 9
40 0.6 60 7
4 49 5
55 0.7 47 7
6 34 10 37 0.8 43 16 10 17 5
38 0.9 29 15 14 0
7 22 1
31 19 12 0
2 29 1.1 13 8
5 0
10 3
1.2 17 13 4
0 13 4
1.3 10 8
2 0
8 2
1.4 8
6 2
0 7
1 1.5 5
5 0
0 5
0 1.6 5
4 1
0 4
1 1.7 4
4 0
0 4
0 1.8 7
6 1
0 6
1 1.9 3
3 0
0 3
0 2
1 1
0 0
1 0
2.1 1
0 1
0 0
1 2.2 4
3 1
0 3
1 2.3 2
2 0
0 2
0 2.5 1
1 0
0 1
0 2.6 1
1 0
0 1
0 2.7 3
3 0
0 3
0 2.8 2
2 0
0 2
0 3
2 2
0 0
2 0
3.3 1
1 0
0 1
0 3.7 1
1 0
0 1
0 3.9 1
1 0
0 1
0 4.9 1
1 0
0 1
0 5.2 1
1 0
0 1
0 6.9 1
1 0
0 1
0 8.1 1
1 0
0 1
0 9.4 1
1 0
0 1
0 Total 400 155 71 174 128 272 Average voltage = 0.924 volt
- This record was final approved on 2/10/2021 3:23:04 PM. (This statement was added by the PRIME system upon its validation)
WESTINGHOUSE NON-PROPRIETARY CLASS 3 3-7 SG-CDMP-21-1-NP February 2021 Revision 0 Table 3-5 U2R3 DSI/DSV Voltage Distribution for SG-4 Voltage Bin Number of Indications
+POINT Probe Confirmed
+POINT Probe Tested But Not Confirmed Not +POINT Probe Tested Plugged Returned to Service 0.2 6
1 1
4 0
6 0.3 25 0
5 20 1
24 0.4 50 0
12 38 2
48 0.5 53 5
6 42 3
50 0.6 37 4
2 31 3
34 0.7 40 2
3 35 2
38 0.8 44 16 14 14 5
39 0.9 24 6
18 0
2 22 1
14 7
7 0
4 10 1.1 9
6 3
0 6
3 1.2 7
2 5
0 2
5 1.3 7
3 4
0 3
4 1.4 3
2 1
0 2
1 1.5 1
1 0
0 1
0 1.8 2
2 0
0 2
0 2.2 1
1 0
0 1
0 2.4 2
2 0
0 2
0 6.1 1
1 0
0 1
0 Total 326 61 81 184 42 284 Average voltage = 0.650 volt
- This record was final approved on 2/10/2021 3:23:04 PM. (This statement was added by the PRIME system upon its validation)
WESTINGHOUSE NON-PROPRIETARY CLASS 3 3-8 SG-CDMP-21-1-NP February 2021 Revision 0 Table 3-6 SG-1 U2R3 Indication Distribution as Function of Tube Support Plate SG TSP Number of Indications Max.
Volts Average Volts Largest
- Growth, Volts Average
- Growth, Volts 1
H01 0
0.00 0.000 0.00 0.00 1
H02 35 1.38 0.656 1.21 0.21 1
H03 56 1.66 0.584 1.51 0.11 1
H04 45 1.32 0.854 0.42 0.12 1
H05 38 1.01 0.517 0.21 0.06 1
H06 16 0.87 0.441 0.14 0.03 1
H07 6
0.47 0.300 0.10 0.02 1
H08 0
0.00 0.000 0.00 0.00 1
C02 0
0.00 0.000 0.00 0.00 1
C05 0
0.00 0.000 0.00 0.00 1
C06 0
0.00 0.000 0.00 0.00 1
C08 0
0.00 0.000 0.00 0.00 1
C09 1
0.34 0.340 0.09 0.09 1
C10 1
0.39 0.390 0.17 0.17 1
C11 0
0.00 0.000 0.00 0.00 1
C12 0
0.00 0.000 0.00 0.00 1
C13 0
0.00 0.000 0.00 0.00 1
C14 2
0.35 0.320 0.06 0.03
- This record was final approved on 2/10/2021 3:23:04 PM. (This statement was added by the PRIME system upon its validation)
WESTINGHOUSE NON-PROPRIETARY CLASS 3 3-9 SG-CDMP-21-1-NP February 2021 Revision 0 Table 3-7 SG-2 U2R3 Indication Distribution as Function of Tube Support Plate SG TSP Number of Indications Max.
Volts Average Volts Largest
- Growth, Volts Average
- Growth, Volts 2
H01 0
0.00 0.000 0.00 0.00 2
H02 103 1.56 0.738 1.22 0.20 2
H03 106 3.82 0.660 3.54 0.20 2
H04 36 1.82 0.683 0.90 0.09 2
H05 34 1.40 0.560 0.31 0.08 2
H06 19 1.00 0.456 0.14 0.04 2
H07 5
0.49 0.386 0.21 0.09 2
H08 9
0.73 0.386 0.10 0.03 2
C02 0
0.00 0.000 0.00 0.00 2
C05 0
0.00 0.000 0.00 0.00 2
C06 0
0.00 0.000 0.00 0.00 2
C08 1
0.26 0.260 0.05 0.05 2
C09 0
0.00 0.000 0.00 0.00 2
C10 0
0.00 0.000 0.00 0.00 2
C11 0
0.00 0.000 0.00 0.00 2
C12 0
0.00 0.000 0.00 0.00 2
C13 1
0.38 0.380 0.03 0.03 2
C14 0
0.00 0.000 0.00 0.00
- This record was final approved on 2/10/2021 3:23:04 PM. (This statement was added by the PRIME system upon its validation)
WESTINGHOUSE NON-PROPRIETARY CLASS 3 3-10 SG-CDMP-21-1-NP February 2021 Revision 0 Table 3-8 SG-3 U2R3 Indication Distribution as Function of Tube Support Plate SG TSP Number of Indications Max.
Volts Average Volts Largest
- Growth, Volts Average
- Growth, Volts 3
H01 3
9.35 3.320 9.35 3.24 3
H02 203 8.03 1.086 7.84 0.73 3
H03 65 3.64 0.926 3.64 0.59 3
H04 71 1.17 0.630 0.72 0.13 3
H05 38 0.98 0.595 0.37 0.08 3
H06 12 0.72 0.525 0.21 0.08 3
H07 5
0.63 0.364 0.14 0.06 3
H08 1
0.51 0.510 0.10 0.10 3
C02 0
0.00 0.000 0.00 0.00 3
C05 1
1.73 1.730 0.39 0.39 3
C06 1
0.99 0.990 0.00 0.00 3
C08 0
0.00 0.000 0.00 0.00 3
C09 0
0.00 0.000 0.00 0.00 3
C10 0
0.00 0.000 0.00 0.00 3
C11 0
0.00 0.000 0.00 0.00 3
C12 0
0.00 0.000 0.00 0.00 3
C13 0
0.00 0.000 0.00 0.00 3
C14 0
0.00 0.000 0.00 0.00
- This record was final approved on 2/10/2021 3:23:04 PM. (This statement was added by the PRIME system upon its validation)
WESTINGHOUSE NON-PROPRIETARY CLASS 3 3-11 SG-CDMP-21-1-NP February 2021 Revision 0 Table 3-9 SG-4 U2R3 Indication Distribution as Function of Tube Support Plate SG TSP Number of Indications Max.
Volts Average Volts Largest
- Growth, Volts Average
- Growth, Volts 4
H01 0
0.00 0.000 0.00 0.00 4
H02 128 6.06 0.704 5.80 0.25 4
H03 87 2.4 0.639 1.71 0.21 4
H04 54 2.4 0.698 1.82 0.19 4
H05 36 1.15 0.574 0.37 0.11 4
H06 10 0.74 0.450 0.74 0.15 4
H07 1
0.31 0.310 0.00 0.00 4
H08 0
0.00 0.000 0.00 0.00 4
C02 1
0.33 0.330 0.00 0.00 4
C05 0
0.00 0.000 0.00 0.00 4
C06 1
0.26 0.260 0.00 0.00 4
C07 0
0.00 0.000 0.00 0.00 4
C09 3
0.39 0.387 0.03 0.01 4
C08 0
0.00 0.000 0.00 0.00 4
C11 1
0.26 0.260 0.03 0.03 4
C12 1
0.28 0.280 0.00 0.00 4
C13 3
0.39 0.303 0.13 0.08 4
C14 0
0.00 0.000 0.00 0.00
- This record was final approved on 2/10/2021 3:23:04 PM. (This statement was added by the PRIME system upon its validation)
WESTINGHOUSE NON-PROPRIETARY CLASS 3 3-12 SG-CDMP-21-1-NP February 2021 Revision 0 Table 3-10 U2R3 Indication Distribution as Function of Tube Support Plate, All SGs Combined SG TSP Number of Indications Max.
Volts Average Volts Largest
- Growth, Volts Average
- Growth, Volts All H01 3
9.35 3.320 9.35 3.24 All H02 469 8.03 0.873 7.84 0.44 All H03 314 3.82 0.696 3.64 0.27 All H04 206 2.4 0.706 1.82 0.13 All H05 146 1.4 0.561 0.37 0.08 All H06 57 1
0.465 0.74 0.06 All H07 17 0.63 0.345 0.21 0.05 All H08 10 0.73 0.398 0.10 0.03 All C02 1
0.33 0.330 0.00 0.00 All C05 1
1.73 1.730 0.39 0.39 All C06 2
0.99 0.625 0.00 0.00 All C08 1
0.26 0.260 0.05 0.05 All C09 4
0.39 0.375 0.09 0.03 All C10 1
0.39 0.390 0.17 0.17 All C11 1
0.26 0.260 0.03 0.03 All C12 1
0.28 0.280 0.00 0.00 All C13 4
0.39 0.323 0.13 0.07 All C14 2
0.35 0.320 0.06 0.03 Table 3-11 SG-1 Voltage Growth Cumulative Distribution Voltage Change:
EOC-3 minus EOC-2 Number of Indications Cumulative Probability Distribution V0.0 73 0.365 0.01V0.1 60 0.665 0.11V0.2 35 0.840 0.21V0.3 14 0.910 0.31V0.4 8
0.950 0.41V0.5 3
0.965 0.51V0.6 1
0.970 0.61V0.7 1
0.975 0.71V0.8 1
0.980 0.81V0.9 1
0.985 1.11V1.2 1
0.990 1.21V1.3 1
0.995 1.51V1.6 1
1.000 Number of Indications w/ Growth 127 Average Growth 0.08V
- This record was final approved on 2/10/2021 3:23:04 PM. (This statement was added by the PRIME system upon its validation)
WESTINGHOUSE NON-PROPRIETARY CLASS 3 3-13 SG-CDMP-21-1-NP February 2021 Revision 0 Table 3-12 SG-2 Voltage Growth Cumulative Distribution Voltage Change:
EOC-3 minus EOC-2 Number of Indications Cumulative Probability Distribution V0.0 97 0.309 0.01V0.1 114 0.672 0.11V0.2 34 0.780 0.21V0.3 22 0.850 0.31V0.4 11 0.885 0.41V0.5 10 0.917 0.51V0.6 9
0.946 0.61V0.7 4
0.959 0.71V0.8 1
0.962 0.81V0.9 2
0.968 0.91V1 1
0.971 1.01V1.1 1
0.975 1.11V1.2 4
0.987 1.21V1.3 1
0.990 1.51V1.6 1
0.994 1.71V1.8 1
0.997 3.51V3.6 1
1.000 Number of Indications w/ Growth 217 Average Growth 0.14V
- This record was final approved on 2/10/2021 3:23:04 PM. (This statement was added by the PRIME system upon its validation)
WESTINGHOUSE NON-PROPRIETARY CLASS 3 3-14 SG-CDMP-21-1-NP February 2021 Revision 0 Table 3-13 SG-3 Voltage Growth Cumulative Distribution Voltage Change:
EOC-3 minus EOC-2 Number of Indications Cumulative Probability Distribution V0.0 43 0.108 0.01V0.1 72 0.288 0.11V0.2 61 0.440 0.21V0.3 36 0.530 0.31V0.4 33 0.613 0.41V0.5 28 0.683 0.51V0.6 25 0.745 0.61V0.7 23 0.803 0.71V0.8 16 0.843 0.81V0.9 7
0.860 0.91V1 8
0.880 1.01V1.1 4
0.890 1.11V1.2 7
0.908 1.21V1.3 3
0.915 1.31V1.4 3
0.923 1.41V1.5 1
0.925 1.51V1.6 3
0.933 1.61V1.7 1
0.935 1.71V1.8 3
0.943 1.81V1.9 3
0.950 1.91V2 2
0.955 2.01V2.1 1
0.957 2.21V2.3 3
0.965 2.31V2.4 1
0.967 2.41V2.5 3
0.975 2.61V2.7 1
0.977 2.71V2.8 1
0.980 3.21V3.3 1
0.982 3.61V3.7 1
0.985 3.81V3.9 1
0.987 4.61V4.7 1
0.990 4.81V4.9 1
0.992 6.81V6.9 1
0.995 7.81V7.9 1
0.997 9.31V9.4 1
1.000 Number of Indications w/ Growth 357 Average Growth 0.52V
- This record was final approved on 2/10/2021 3:23:04 PM. (This statement was added by the PRIME system upon its validation)
WESTINGHOUSE NON-PROPRIETARY CLASS 3 3-15 SG-CDMP-21-1-NP February 2021 Revision 0 Table 3-14 SG-4 Voltage Growth Cumulative Distribution Voltage Change:
EOC-3 minus EOC-2 Number of Indications Cumulative Probability Distribution V0.0 63 0.193 0.01V0.1 95 0.485 0.11V0.2 64 0.681 0.21V0.3 33 0.782 0.31V0.4 27 0.865 0.41V0.5 14 0.908 0.51V0.6 12 0.945 0.61V0.7 8
0.969 0.71V0.8 5
0.985 0.81V0.9 1
0.988 0.91V1 1
0.991 1.71V1.8 1
0.994 1.81V1.9 1
0.997 5.71V5.8 1
1.000 Number of Indications w/ Growth 263 Average Growth 0.19V
- This record was final approved on 2/10/2021 3:23:04 PM. (This statement was added by the PRIME system upon its validation)
WESTINGHOUSE NON-PROPRIETARY CLASS 3 3-16 SG-CDMP-21-1-NP February 2021 Revision 0 Table 3-15 Voltage Growth Cumulative Distribution, All SGs Voltage Change:
EOC-3 Minus EOC-2 Number of Indications Cumulative Probability Distribution V0.0 276 0.223 0.01V0.1 341 0.498 0.11V0.2 194 0.654 0.21V0.3 105 0.739 0.31V0.4 79 0.802 0.41V0.5 55 0.847 0.51V0.6 47 0.885 0.61V0.7 36 0.914 0.71V0.8 23 0.932 0.81V0.9 11 0.941 0.91V1 10 0.949 1.01V1.1 5
0.953 1.11V1.2 12 0.963 1.21V1.3 5
0.967 1.31V1.4 3
0.969 1.41V1.5 1
0.970 1.51V1.6 5
0.974 1.61V1.7 1
0.975 1.71V1.8 5
0.979 1.81V1.9 4
0.982 1.91V2 2
0.984 2.01V2.1 1
0.985 2.21V2.3 3
0.987 2.31V2.4 1
0.988 2.41V2.5 3
0.990 2.61V2.7 1
0.991 2.71V2.8 1
0.992 3.21V3.3 1
0.993 3.51V3.6 1
0.994 3.61V3.7 1
0.994 3.81V3.9 1
0.995 4.61V4.7 1
0.996 4.81V4.9 1
0.997 5.71V5.8 1
0.998 6.81V6.9 1
0.998 7.81V7.9 1
0.999 9.31V9.4 1
1.000
- This record was final approved on 2/10/2021 3:23:04 PM. (This statement was added by the PRIME system upon its validation)
WESTINGHOUSE NON-PROPRIETARY CLASS 3 3-17 SG-CDMP-21-1-NP February 2021 Revision 0 Table 3-16 Indications with Largest Growth in Cycle 3 SGID Row Col Locn U2R3 Vpp U2R2 Vpp Cycle 3 Vpp Growth RPC Tested 3
17 54 H01 9.35 0.00 9.35 Yes (SAI) 3 12 111 H02 8.03 0.19 7.84 Yes (MAI) 3 17 46 H02 6.87 0.00 6.87 Yes (MAI) 4 6
36 H02 6.06 0.26 5.80 Yes (SAI) 3 17 47 H02 5.13 0.24 4.90 Yes (MAI) 3 14 7
H02 4.83 0.15 4.68 Yes (SAI) 3 7
62 H02 3.83 0.00 3.83 Yes (SAI) 3 4
109 H03 3.64 0.00 3.64 Yes (SAI) 2 40 53 H03 3.82 0.29 3.54 Yes (SAI) 3 48 57 H02 3.21 0.00 3.21 Yes (MAI) 3 18 108 H02 2.96 0.16 2.8 Yes (MAI) 3 5
106 H03 2.67 0.00 2.67 Yes (SAI) 3 8
92 H02 2.73 0.24 2.49 Yes (SAI) 3 18 109 H02 2.72 0.29 2.44 Yes (MAI) 3 19 10 H02 2.58 0.17 2.42 Yes (MAI) 3 18 101 H02 2.66 0.31 2.35 Yes (SAI) 3 14 108 H02 2.48 0.21 2.27 Yes (MAI) 3 21 38 H02 2.26 0.00 2.26 Yes (MAI) 3 35 18 H02 2.62 0.39 2.23 Yes (SAI) 3 9
9 H02 2.95 0.87 2.08 Yes (SAI) 3 4
109 H02 2.26 0.26 2.00 Yes (SAI) 3 5
107 H02 2.12 0.21 1.91 Yes (MAI) 3 46 54 H02 1.90 0.00 1.90 Yes (MAI)
- This record was final approved on 2/10/2021 3:23:04 PM. (This statement was added by the PRIME system upon its validation)
WESTINGHOUSE NON-PROPRIETARY CLASS 3 3-18 SG-CDMP-21-1-NP February 2021 Revision 0 Figure 3-1 Voltage Distribution in SG-1 Figure 3-2 Voltage Distribution in SG-2 0
5 10 15 20 25 30 35 40 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1
1.1 1.2 1.3 1.4 1.7 Count Volts SG-1 Voltage Distribution at EOC-3 0
10 20 30 40 50 60 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1
1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2.1 3.9 Count Volts SG-2 Voltage Distribution at EOC-3
- This record was final approved on 2/10/2021 3:23:04 PM. (This statement was added by the PRIME system upon its validation)
WESTINGHOUSE NON-PROPRIETARY CLASS 3 3-19 SG-CDMP-21-1-NP February 2021 Revision 0 Figure 3-3 Voltage Distribution in SG-3 Figure 3-4 Voltage Distribution in SG-4 0
10 20 30 40 50 60 70 0.2 0.4 0.6 0.8 1
1.2 1.4 1.6 1.8 2
2.2 2.5 2.7 3
3.7 4.9 6.9 9.4 Count Volts SG-3 Voltage Distribution at EOC-3 0
10 20 30 40 50 60 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1
1.1 1.2 1.3 1.4 1.5 1.8 2.2 2.4 6.1 Count Volts SG-4 Voltage Distribution at EOC-3
- This record was final approved on 2/10/2021 3:23:04 PM. (This statement was added by the PRIME system upon its validation)
WESTINGHOUSE NON-PROPRIETARY CLASS 3 3-20 SG-CDMP-21-1-NP February 2021 Revision 0 Figure 3-5 Indication Distribution by TSP 0
25 50 75 100 125 150 175 200 H01 H02 H03 H04 H05 H06 H07 H08 C14 C13 C12 C11 C10 C09 C08 C06 C05 C02 Count of Indications by TSP SG1 SG2 SG3 SG4
- This record was final approved on 2/10/2021 3:23:04 PM. (This statement was added by the PRIME system upon its validation)
WESTINGHOUSE NON-PROPRIETARY CLASS 3 3-21 SG-CDMP-21-1-NP February 2021 Revision 0 Figure 3-6 Voltage Growth during Cycle 3 0
0.2 0.4 0.6 0.8 1
1.2
-2 0
2 4
6 8
10 CDF Delta V Voltage Growth Distribution by SG SG1 Growth SG2 Growth SG3 Growth SG4 Growth
- This record was final approved on 2/10/2021 3:23:04 PM. (This statement was added by the PRIME system upon its validation)
WESTINGHOUSE NON-PROPRIETARY CLASS 3 3-22 SG-CDMP-21-1-NP February 2021 Revision 0 Figure 3-7 Upper 5% of Voltage Growth during Cycle 3 0.95 0.96 0.97 0.98 0.99 1
1.01
-2 0
2 4
6 8
10 CDF Delta V Upper 5% of Voltage Growth Distribution by SG SG1 Growth SG2 Growth SG3 Growth SG4 Growth
- This record was final approved on 2/10/2021 3:23:04 PM. (This statement was added by the PRIME system upon its validation)
WESTINGHOUSE NON-PROPRIETARY CLASS 3 3-23 SG-CDMP-21-1-NP February 2021 Revision 0 Figure 3-8 Cycle 3 Voltage Growth vs. BOC Voltage y = -0.6523x + 0.5707 R² = 0.0979
-1 0
1 2
3 4
5 0
0.5 1
1.5 2
2.5 Voltage Growth (Delta V)
BOC-3 Volts Cycle 3 DSI Growth vs. BOC-3 Voltage SG1 DSIs SG2 DSIs SG3 DSIs SG4 DSIs All Linear (All)
- This record was final approved on 2/10/2021 3:23:04 PM. (This statement was added by the PRIME system upon its validation)
WESTINGHOUSE NON-PROPRIETARY CLASS 3 4-1 SG-CDMP-21-1-NP February 2021 Revision 0 4
DATABASE APPLIED FOR LEAK AND BURST CORRELATIONS 4.1 Tube Material Properties The tube material properties are provided in Table 4-1 of Reference 2 for the 3/4-inch diameter tubes in the WB2 SGs at 650°F. The normalized mean flow stress (sum of yield and ultimate strengths divided by 2) used in the analysis is 71.565 ksi with a standard deviation of 3.565 ksi.
4.2 Burst Correlation The burst pressure, Pb, is normalized to a material with a flow stress of 71.565 ksi, which is the mean of the Westinghouse 3/4-inch tube data. This aligns with the flow stress values used in the burst pressure analysis. The correlation parameters used in the analysis are taken from Table 6-1 in Reference 4.
4.3 Leak Rate Correlation The steam line break pressure to be applied is typically 2560 psi unless a lower pressure can be justified. At WB2, credit can be taken for operability of the pressurizer PORVs during a SLB event.
Therefore, the SLB primary-to-secondary pressure differential was selected as 2405 psi for the leak correlation per Reference 13 which is used for the leakage predictions in this analysis. The parameters used in the analysis are taken from Table 6-3 in Reference 4. The leak rate criterion is given in terms of gallons per minute as condensed liquid at room temperature.
4.4 Probability of Leak Correlation The probability of leak as a function of indication voltage parameters are taken from Table 6-2 of Reference 4. In the Monte Carlo analysis, leakage is quantified only if the indication is computed to be a leaker, based on the probability of leak correlation.
4.5 NDE Uncertainties The NDE uncertainties applied for the EOC-3 and EOC-4a voltage projections are described in Reference 1. The probe wear uncertainty has a standard deviation of 7% about a mean of zero and has a cut-off at 15% based on implementation of the probe wear standard. The analyst variability uncertainty has a standard deviation of 10.3% about a mean of zero with no cut-off. These NDE uncertainty distributions are used in the Monte Carlo analysis to predict the burst probabilities and accident leak rates at EOC-3 and EOC-4a.
- This record was final approved on 2/10/2021 3:23:04 PM. (This statement was added by the PRIME system upon its validation)
WESTINGHOUSE NON-PROPRIETARY CLASS 3 5-1 SG-CDMP-21-1-NP February 2021 Revision 0 5
SLB ANALYSIS METHODS A Monte Carlo analysis technique is used to calculate the SLB leak rates and tube burst probabilities for both actual U2R3 and projected EOC-4a voltage distributions. The Monte Carlo analysis accounts for parameter uncertainty. The analysis methodology is described in the Westinghouse generic methods report of Reference 4 as supplemented by References 5 and 6. The Monte Carlo computer program used to implement this method is documented in Reference 9.
In general, the methodology involves application of correlations for burst pressure, probability of leakage and leak rate to a measured or calculated EOC voltage distribution to estimate the likelihood of tube burst and primary-to-secondary leakage during a postulated SLB event. Uncertainties associated with burst pressure, leak rate probability and leak rate correlation parameters are explicitly included by sampling distributions for the parameter uncertainties through the Monte Carlo sampling process. NDE uncertainties are also included. The voltage distributions used in the leak and burst projections for the next operating cycle are obtained by applying growth data to the BOC distribution.
- This record was final approved on 2/10/2021 3:23:04 PM. (This statement was added by the PRIME system upon its validation)
WESTINGHOUSE NON-PROPRIETARY CLASS 3 6-1 SG-CDMP-21-1-NP February 2021 Revision 0 6
BOBBIN VOLTAGE DISTRIBUTIONS This section describes the input data used to calculate EOC bobbin voltage distributions and presents results of calculations to project EOC-4a voltage distributions. The cycle length used to project the EOC condition at the planned mid-cycle outage (EOC-4a) for the operational assessment is 285 days.
6.1 Calculation of Voltage Distributions An initial voltage distribution for BOC-4a is determined based on the EOC-3 voltage distribution and the POD. The BOC-4a voltage distribution is projected to the end-of-cycle conditions based on the growth rate and the anticipated cycle operating duration. The POD applied was specifically developed for Watts Bar Unit 2 for use in GL 95-05 calculations for Cycle 4 and is discussed in greater detail in Section 6.2. The calculation of projected bobbin voltage frequency distribution is based on a net total number of indications returned to service, defined as follows.
NTot RTS = Ni / POD - Nrepaired + Ndeplugged
- where, NTot RTS
= Number of bobbin indications being returned to service for the next cycle, Ni
=
Number of bobbin indications (in tubes in service) identified by inspection after the previous cycle, POD =
Probability of detection, Nrepaired
= Number of Ni which are repaired (plugged) after the last cycle, Ndeplugged
= Number of indications in tubes deplugged after the last cycle and returned to service in accordance with voltage-based repair criteria.
There are no deplugged tubes returned to service at the beginning of Cycle 4a (BOC-4a); therefore, Ndeplugged = 0. Several tubes were plugged due to DSI exceeding the upper repair limit, RPC confirmed above the lower repair limit, or for other degradation mechanisms. During the Monte Carlo simulations, voltages for bins with several indications are selected by randomly sampling the voltage bins.
The methodology used in the projection of EOC-4a bobbin voltage frequency distributions is described in Reference 3.
6.2 Probability of Detection (POD)
The Generic Letter 95-05 (Reference 1) requires the application of a constant POD value of 0.6 to define the BOC distribution for EOC voltage projections unless an alternate POD is approved by the NRC. A POD value of 1.0 represents the ideal situation where all indications are detected.
Reference 10 provides the technical basis for the use of an alternate POD at Watts Bar Unit 2 for
- This record was final approved on 2/10/2021 3:23:04 PM. (This statement was added by the PRIME system upon its validation)
WESTINGHOUSE NON-PROPRIETARY CLASS 3 6-2 SG-CDMP-21-1-NP February 2021 Revision 0 Cycle 4a GL 95-05 ARC calculations. The POD is a step function where the default value of 0.6 is used up to an indication size of 3.2V at which point the POD increases to 0.9. A POD of 0.9 is maintained up to an indication size of 6.0V, at which point the POD increases to 0.95. The POD is developed based on the inspection technique implemented at U2R3 as well as WB2 plant-specific noise. The POD is applied to all four SGs for determination of BOC-4a flaw distributions. NRC approval of the alternate POD is documented in Reference 12.
6.3 Limiting Growth Rate Distribution As discussed in Section 3.2, the NRC guidelines in Generic Letter 95-05 stipulate that the more conservative growth rate distributions from the past two inspections should be utilized for projecting EOC distributions for the next cycle. Since EOC-3 is the first application of GL 95-05 at Watts Bar Unit 2 and relatively few DSI indications were recorded during EOC-2 inspections, the Cycle 3 growth is limiting. The Cycle 3 growth distributions were determined utilizing bobbin lookbacks of U2R2 eddy current testing (ECT) data to develop meaningful growth distributions which contain at least 200 growth points. Growth distributions were determined for each individual SG and can be seen in Figure 6-3. Performing the lookbacks and creating distributions for each SG provides a more comprehensive and accurate look at the voltage growth that has occurred over the past cycle. For conservatism, the bounding growth curve (SG-3) was used as input for the operational assessment performed individually for each SG. Growth distributions used in the Monte Carlo calculations are specified in the form of a histogram, so no interpolation is performed between growth bins. This assures that the largest growth value in the distribution is utilized in the Monte Carlo simulations.
6.4 Cycle Operating Period The operating periods used in the growth rate/EFPY calculations and voltage projections are as follows.
Cycle 3 496.3 EFPD (actual)
Partial Cycle 4 (Cycle 4a) -285 EFPD* (assumed)
- The cycle length of 285 days which is selected for the OA is calculated to be the maximum amount of days SG-3 could operate into Cycle 4 and meet the acceptance criteria for POB. The OA duration is measured in calendar days since WB2 is currently operating at less than 100%
power and it is unknown at the time of this report whether that power level will be maintained or adjusted prior to the planned mid-cycle outage. The use of EFPD in tube integrity calculations is intended to account for startups, cooldowns and downpowers; it is not intended for use in extension of the cycle length due to operating at a lower power. Therefore, although the reported value is EFPD, in this circumstance that value should be considered to be calendar days of operation without adjustment for operating power levels.
- This record was final approved on 2/10/2021 3:23:04 PM. (This statement was added by the PRIME system upon its validation)
WESTINGHOUSE NON-PROPRIETARY CLASS 3 6-3 SG-CDMP-21-1-NP February 2021 Revision 0 6.5 Projected EOC-4a Voltage Distribution Calculations for the EOC-4a bobbin voltage projections were performed for all four SGs based on the U2R3 distributions shown in Table 6-1. The BOC-4a distributions were adjusted to account for probability of detection as described above, and the adjusted number of indications at BOC-4a is also shown in Table 6-1. Calculations were performed using the alternate POD described in Section 6.2 and 1,000,000 Monte Carlo trials. The distribution of indications at BOC-4a and the distribution of indications projected at EOC-4a are shown in Figure 6-1, Figure 6-2, Figure 6-3, and Figure 6-4 for SG-1, SG-2, SG-3 and SG-4, respectively. SG-3 has the largest number of indications at BOC-4a. For clarity, fractional EOC voltage predictions below 1.0 are not shown in Figure 6-1, Figure 6-2, Figure 6-3, and Figure 6-4. Therefore, higher voltage bins are not displayed in these figures. The maximum voltage where a fractional number of indications are projected at EOC-4a is displayed in Table 7-2 for each SG. Fractional values are considered in the determination of probability of burst and leak rates for the OA calculation.
- This record was final approved on 2/10/2021 3:23:04 PM. (This statement was added by the PRIME system upon its validation)
WESTINGHOUSE NON-PROPRIETARY CLASS 3 6-4 SG-CDMP-21-1-NP February 2021 Revision 0 Table 6-1 Predicted Voltage Distribution Volt Bins SG-1 Number of Indications SG-2 Number of Indications SG-3 Number of Indications SG-4 Number of Indications Measured Input Predicted Measured Input Predicted Measured Input Predicted Measured Input Predicted EOC-3 BOC-4 EOC-4 EOC-3 BOC-4 EOC-4 EOC-3 BOC-4 EOC-4 EOC-3 BOC-4 EOC-4 0.1 0
0 0.01 0
0 0.06 0
0 0.01 0
0 0.05 0.2 1
1.67 0.67 7
11.67 3.04 2
2.33 0.74 6
10 2.71 0.3 15 25 6.69 23 38.33 12.37 12 18 5.33 25 40.67 12.68 0.4 29 48.33 17.69 43 70.67 27.61 30 46 16.14 50 81.33 30.02 0.5 35 58.33 27.86 52 86.67 42.66 49 72.67 31.39 53 85.33 44.52 0.6 26 42.33 33.58 43 70.67 51.24 60 95 46.21 37 58.67 50.73 0.7 31 51.67 36.81 37 61.67 53.89 47 68.33 54.28 40 64.67 54.34 0.8 22 34.67 36.43 29 47.33 52.06 43 66.67 56.15 44 68.33 55.07 0.9 13 21.67 32.22 27 36 46.99 29 41.33 53.78 24 38 49.85 1
10 16.67 27.32 19 30.67 40.22 31 49.67 48.19 14 19.33 41.91 1.1 4
6.67 22.62 7
8.67 33.03 13 11.67 40.62 9
9 34.26 1.2 7
9.67 17.93 5
6.33 26.14 17 15.33 33.05 7
9.67 26.61 1.3 4
5.67 13.93 7
9.67 20.28 10 8.67 26.18 7
8.67 20 1.4 2
3.33 10.95 5
6.33 15.79 8
6.33 20.24 3
3 15.46 1.5 0
0 8.4 3
2 12.41 5
3.33 15.79 1
0.67 12 1.6 0
0 6.4 1
0.67 9.9 5
4.33 12.7 0
0 9.11 1.7 1
0.67 4.99 2
2.33 7.97 4
2.67 10.46 0
0 7.07 1.8 0
0 3.96 1
0.67 6.49 7
5.67 8.76 2
1.33 5.69 1.9 0
0 3.1 1
1.67 5.25 3
2 7.48 0
0 4.53 2
0 0
2.41 0
0 4.19 1
0.67 6.37 0
0 3.59 2.1 0
0 1.83 1
0.67 3.25 1
1.67 5.32 0
0 2.82 2.2 0
0 1.32 0
0 2.42 4
3.67 4.39 1
0.67 2.12 2.3 0
0 0.95 0
0 1.82 2
1.33 3.57 0
0 1.63 2.4 0
0 0.77 0
0 1.44 0
0 2.96 2
1.33 1.38 2.5 0
0 0.66 0
0 1.2 1
0.67 2.54 0
0 1.2 2.6 0
0 0.53 0
0 0.97 1
0.67 2.23 0
0 0.96 2.7 0
0 0.41 0
0 0.73 3
2 1.94 0
0 0.74
- This record was final approved on 2/10/2021 3:23:04 PM. (This statement was added by the PRIME system upon its validation)
WESTINGHOUSE NON-PROPRIETARY CLASS 3 6-5 SG-CDMP-21-1-NP February 2021 Revision 0 Table 6-1 Predicted Voltage Distribution Volt Bins SG-1 Number of Indications SG-2 Number of Indications SG-3 Number of Indications SG-4 Number of Indications Measured Input Predicted Measured Input Predicted Measured Input Predicted Measured Input Predicted EOC-3 BOC-4 EOC-4 EOC-3 BOC-4 EOC-4 EOC-3 BOC-4 EOC-4 EOC-3 BOC-4 EOC-4 2.8 0
0 0.33 0
0 0.56 2
1.33 1.64 0
0 0.61 2.9 0
0 0.26 0
0 0.49 0
0 1.41 0
0 0.55 3
0 0
0.3 0
0 0.54 2
1.33 1.28 0
0 0.6 3.1 0
0 0.4 0
0 0.65 0
0 1.25 0
0 0.71 3.2 0
0 0.44 0
0 0.69 0
0 1.25 0
0 0.71 3.3 0
0 0.41 0
0 0.64 1
0.11 1.19 0
0 0.62 3.4 0
0 0.36 0
0 0.53 0
0 1.05 0
0 0.55 3.5 0
0 0.29 0
0 0.43 0
0 0.86 0
0 0.48 3.6 0
0 0.21 0
0 0.33 0
0 0.69 0
0 0.36 3.7 0
0 0.14 0
0 0.24 1
0.11 0.54 0
0 0.24 3.8 0
0 0.1 0
0 0.16 0
0 0.4 0
0 0.15 3.9 0
0 0.07 1
0.11 0.11 1
0.11 0.29 0
0 0.1 4
0 0
0.05 0
0 0.08 0
0 0.21 0
0 0.06 4.1 0
0 0.03 0
0 0.07 0
0 0.16 0
0 0.06 4.2 0
0 0.05 0
0 0.11 0
0 0.15 0
0 0.09 4.3 0
0 0.11 0
0 0.17 0
0 0.19 0
0 0.17 4.4 0
0 0.14 0
0 0.22 0
0 0.24 0
0 0.21 4.5 0
0 0.13 0
0 0.21 0
0 0.27 0
0 0.18 4.6 0
0 0.12 0
0 0.18 0
0 0.25 0
0 0.17 4.7 0
0 0.11 0
0 0.17 0
0 0.22 0
0 0.19 4.8 0
0 0.13 0
0 0.21 0
0 0.22 0
0 0.23 4.9 0
0 0.16 0
0 0.25 1
0.11 0.25 0
0 0.27 5
0 0
0.16 0
0 0.25 0
0 0.28 0
0 0.24 5.1 0
0 0.14 0
0 0.21 0
0 0.28 0
0 0.2 5.2 0
0 0.13 0
0 0.17 1
0.11 0.25 0
0 0.18 5.3 0
0 0.1 0
0 0.14 0
0 0.21 0
0 0.15 5.4 0
0 0.01 0
0 0.1 0
0 0.16 0
0 0.11
- This record was final approved on 2/10/2021 3:23:04 PM. (This statement was added by the PRIME system upon its validation)
WESTINGHOUSE NON-PROPRIETARY CLASS 3 6-6 SG-CDMP-21-1-NP February 2021 Revision 0 Table 6-1 Predicted Voltage Distribution Volt Bins SG-1 Number of Indications SG-2 Number of Indications SG-3 Number of Indications SG-4 Number of Indications Measured Input Predicted Measured Input Predicted Measured Input Predicted Measured Input Predicted EOC-3 BOC-4 EOC-4 EOC-3 BOC-4 EOC-4 EOC-3 BOC-4 EOC-4 EOC-3 BOC-4 EOC-4 5.5 0
0 0
0 0
0.08 0
0 0.13 0
0 0.07 5.6 0
0 0
0 0
0.1 0
0 0.11 0
0 0.09 5.7 0
0 0
0 0
0.15 0
0 0.13 0
0 0.16 5.8 0
0 0
0 0
0.12 0
0 0.18 0
0 0.16 5.9 0
0 0.7 0
0 0
0 0
0.23 0
0 0
6 0
0 0
0 0
0 0
0 0.23 0
0 0
6.1 0
0 0
0 0
0.7 0
0 0.02 1
0.05 0.7 6.2 0
0 0.3 0
0 0
0 0
0 0
0 0
6.3 0
0 0
0 0
0.3 0
0 0.7 0
0 0.3 6.4 0
0 0
0 0
0 0
0 0
0 0
0 6.5 0
0 0
0 0
0 0
0 0
0 0
0 6.6 0
0 0
0 0
0 0
0 0
0 0
0 6.7 0
0 0
0 0
0 0
0 0
0 0
0 6.8 0
0 0
0 0
0 0
0 0
0 0
0 6.9 0
0 0
0 0
0 1
0.05 0.3 0
0 0
7 0
0 0
0 0
0 0
0 0
0 0
0 7.1 0
0 0
0 0
0 0
0 0
0 0
0 7.2 0
0 0
0 0
0 0
0 0
0 0
0 7.3 0
0 0
0 0
0 0
0 0
0 0
0 7.4 0
0 0
0 0
0 0
0 0
0 0
0 7.5 0
0 0
0 0
0 0
0 0
0 0
0 7.6 0
0 0
0 0
0 0
0 0
0 0
0 7.7 0
0 0
0 0
0 0
0 0
0 0
0 7.8 0
0 0
0 0
0 0
0 0
0 0
0 7.9 0
0 0
0 0
0 0
0 0
0 0
0 8
0 0
0 0
0 0
0 0
0 0
0 0
8.1 0
0 0
0 0
0 1
0.05 0
0 0
0
- This record was final approved on 2/10/2021 3:23:04 PM. (This statement was added by the PRIME system upon its validation)
WESTINGHOUSE NON-PROPRIETARY CLASS 3 6-7 SG-CDMP-21-1-NP February 2021 Revision 0 Table 6-1 Predicted Voltage Distribution Volt Bins SG-1 Number of Indications SG-2 Number of Indications SG-3 Number of Indications SG-4 Number of Indications Measured Input Predicted Measured Input Predicted Measured Input Predicted Measured Input Predicted EOC-3 BOC-4 EOC-4 EOC-3 BOC-4 EOC-4 EOC-3 BOC-4 EOC-4 EOC-3 BOC-4 EOC-4 8.2 0
0 0
0 0
0 0
0 0
0 0
0 8.3 0
0 0
0 0
0 0
0 0
0 0
0 8.4 0
0 0
0 0
0 0
0 0
0 0
0 8.5 0
0 0
0 0
0 0
0 0
0 0
0 8.6 0
0 0
0 0
0 0
0 0
0 0
0 8.7 0
0 0
0 0
0 0
0 0
0 0
0 8.8 0
0 0
0 0
0 0
0 0
0 0
0 8.9 0
0 0
0 0
0 0
0 0
0 0
0 9
0 0
0 0
0 0
0 0
0 0
0 0
9.1 0
0 0
0 0
0 0
0 0
0 0
0 9.2 0
0 0
0 0
0 0
0 0
0 0
0 9.3 0
0 0
0 0
0 0
0 0
0 0
0 9.4 0
0 0
0 0
0 1
0.05 0
0 0
0 Total 200 326 326 314 493 493 400 534 534 326 501 501
- This record was final approved on 2/10/2021 3:23:04 PM. (This statement was added by the PRIME system upon its validation)
WESTINGHOUSE NON-PROPRIETARY CLASS 3 6-8 SG-CDMP-21-1-NP February 2021 Revision 0 Figure 6-1 SG-1 Voltage Distributions 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1
1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2
2.1 2.2 2.3 Number of Indications Voltage Bin SG1 Measured EOC-3 SG1 Input BOC-4 SG1 Predicted EOC-4
- This record was final approved on 2/10/2021 3:23:04 PM. (This statement was added by the PRIME system upon its validation)
WESTINGHOUSE NON-PROPRIETARY CLASS 3 6-9 SG-CDMP-21-1-NP February 2021 Revision 0 Figure 6-2 SG-2 Voltage Distributions 0
10 20 30 40 50 60 70 80 90 100 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1
1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2
2.1 2.2 2.3 2.4 2.5 2.6 Number of Indications Voltage Bin SG2 Measured EOC-3 SG2 Input BOC-4 SG2 Predicted EOC-4
- This record was final approved on 2/10/2021 3:23:04 PM. (This statement was added by the PRIME system upon its validation)
WESTINGHOUSE NON-PROPRIETARY CLASS 3 6-10 SG-CDMP-21-1-NP February 2021 Revision 0 Figure 6-3 SG-3 Voltage Distributions 0
10 20 30 40 50 60 70 80 90 100 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1
1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2
2.1 2.2 2.3 2.4 2.5 2.6 2.7 2.8 2.9 3
3.1 3.2 3.3 3.4 3.5 Number of Indications Voltage Bin SG3 Measured EOC-3 SG3 Input BOC-4 SG3 Predicted EOC-4
- This record was final approved on 2/10/2021 3:23:04 PM. (This statement was added by the PRIME system upon its validation)
WESTINGHOUSE NON-PROPRIETARY CLASS 3 6-11 SG-CDMP-21-1-NP February 2021 Revision 0 Figure 6-4 SG-4 Voltage Distributions 0
10 20 30 40 50 60 70 80 90 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1
1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2
2.1 2.2 2.3 2.4 2.5 2.6 Number of Indications Voltage Bin SG4 Measured EOC-3 SG4 Input BOC-4 SG4 Predicted EOC-4
- This record was final approved on 2/10/2021 3:23:04 PM. (This statement was added by the PRIME system upon its validation)
WESTINGHOUSE NON-PROPRIETARY CLASS 3 7-1 SG-CDMP-21-1-NP February 2021 Revision 0 7
SLB LEAK RATE AND TUBE BURST PROBABILITY ANALYSES This section presents the results of the analyses carried out to predict leak rates and tube burst probabilities at the postulated SLB conditions using the actual voltage distributions from the U2R3 inspection (condition monitoring assessment) as well as for the projected EOC-4a voltage distributions (operational assessment). The methodology used in these analyses is described in Section 6.
7.1 U2R3 Condition Monitoring Leak Rate and Tube Burst Probability Analyses to calculate the U2R3 SLB leak rates and tube burst probabilities were performed using the actual bobbin voltage distributions presented in Table 3-2,Table 3-3,Table 3-4, and Table 3-5. The results of the Monte Carlo calculations are summarized in Table 7-1. As a result, the OA produces conservative results for leak rate and burst probability by the end of the next operating cycle.
The SLB leak rates and tube burst probabilities, calculated using the actual measured U2R3 voltage distributions using 1,000,000 Monte Carlo trials, are shown in Table 7-1. The methodology used for these calculations is documented in WCAP-14277, Revision 1 (Reference 3). The probability of leak, leak rate, and burst pressure correlations for 3/4-inch tubes presented in the latest addendum to the Electric Power Research Institute (EPRI) Alternate Repair Criteria (ARC)
Database, Reference 4, were used. The SLB primary-to-secondary pressure differential applied in the analysis is 2405 psi (Reference 13). While the leak rate and conditional burst probability acceptance criteria are met for SGs 1, 2 and 4, SG-3 did not meet condition monitoring criteria with a conditional burst probability of 3.005 x 10-2. This conclusion was reported to the NRC during U2R3 (Reference 14).
7.2 EOC-4a Operational Assessment Leak Rate and Tube Burst Probability The SLB leak rate and tube burst probability projections for the Cycle 4 Operational Assessment were performed using the latest update to the ARC database documented in Reference 4, the NRC approved alternate POD described in Section 6.2, and 1,000,000 Monte Carlo trials. The EOC-4a leak and burst analyses were performed using a primary-to-secondary pressure differential of 2405 psi, which credits PORV actuation prior to the pressurizer safety relief valve lift setting (Reference 13).
The EOC-4a projections considering a 285 calendar day operation cycle and using the alternate POD discussed in Section 6.2 are displayed in Table 7-2. Both the maximum projected EOC-4a leak rate of 0.47 gpm and the maximum conditional burst probability of 9.610 x 10-3 are below the allowable limits (3.0 gpm and 1.0 x 10-2, respectively). Therefore, the operational assessment performance criteria for the U2R3 flaw distribution are satisfied for 285 calendar days of operation into Cycle 4.
- This record was final approved on 2/10/2021 3:23:04 PM. (This statement was added by the PRIME system upon its validation)
WESTINGHOUSE NON-PROPRIETARY CLASS 3 7-2 SG-CDMP-21-1-NP February 2021 Revision 0 Table 7-1 Condition Monitoring Leak and Burst Results for U2R3 SG Number of Indications Maximum Voltage SLB Leak Rate Conditional Burst Probability GL 95-05 Criteria Met SLB Leak Rate (gpm)
SLB Leak Rate Criteria (gpm)
Conditional Probability of Burst Conditional Probability of Burst Criteria 1
200 1.7 2.52 x 10-3 3.0 3.724 x 10-5 1.0 x 10-2 Yes 2
314 3.9 3.42 x 10-2 4.501 x 10-4 Yes 3
400 9.4 1.09 3.005 x 10-2 No 4
326 6.1 1.56 x 10-1 3.014 x 10-3 Yes Table 7-2 Operational Assessment Leak and Burst Results for EOC-4a SG Number of Indications at 285 Days Maximum Voltage at 285 Days SLB Leak Rate Conditional Burst Probability GL 95-05 Criteria Met for 285 days SLB Leak Rate (gpm)
SLB Leak Rate Criteria (gpm)
Conditional Probability of Burst Conditional Probability of Burst Criteria 1
326 6.2 0.213 3.0 3.502 x 10-3 1.0 x 10-2 Yes 2
493 6.3 0.303 5.450 x 10-3 Yes 3
534 6.9 0.479 9.812 x 10-3 Yes 4
501 6.3 0.309 5.708 x 10-3 Yes
- This record was final approved on 2/10/2021 3:23:04 PM. (This statement was added by the PRIME system upon its validation)
WESTINGHOUSE NON-PROPRIETARY CLASS 3 8-1 SG-CDMP-21-1-NP February 2021 Revision 0 8
REFERENCES
- 1.
NRC Generic Letter 95-05, Voltage-Based Repair Criteria for Westinghouse Steam Generator Tubes Affected by Outside Diameter Stress Corrosion Cracking, USNRC Office of Nuclear Reactor Regulation, August 3, 1995.
- 2.
Steam Generator Management Program: Steam Generator Degradation Specific Management Flaw Handbook, Revision 2. EPRI, Palo Alto, CA: 2015. 3002005426.
- 3.
Westinghouse Report WCAP-14277, Revision 1, SLB Leak Rate and Tube Burst Probability Analysis Methods for ODSCC at TSP Intersections, Westinghouse Nuclear Services Division, December 1996.
- 4.
EPRI Report 1018047, Addendum 7 to NP-7480-L Database, Steam Generator Tubing Outside Diameter Stress Corrosion Cracking at Tube Support Plates Database for Alternate Repair Limits, September 2008.
- 5.
Letter from A. Marion, Nuclear Energy Research Institute, to B. Sheron, Nuclear Regulatory Commission, Refining the Leak Rate Sampling Methodology for ODSCC ARC Applications (Generic Letter 95-05), March 15, 2002.
- 6.
Letter from W. Bateman, Nuclear Regulatory Commission, to A. Marion, Nuclear Energy Research Institute, Refining the Leak Rate Sampling Methodology for Generic Letter 95-05 Voltage-Based Alternate Repair Criteria Application, March 27, 2002.
- 7.
Westinghouse Letter Report, WAT-D-10709, Revision 0, Application of Implementation of Voltage Based Repair Criteria Westinghouse Steam Generator Tubes Affected by ODSCC at TSPs, January 2000.
- 8.
Letter from B.W. Sheron, Nuclear Regulatory Commission, to A. Marion, Nuclear Energy Research Institute, February 9, 1996.
- 9.
Westinghouse Letter LTR-CDME-08-167, Revision 0, Software Release Letter for CycleSim Version 3.2, July 2008.
- 10. Westinghouse Letter, LTR-CDMP-20-41, Revision 0, Watts Bar U2R3 Steam Generator Alternate Repair Criteria Generic Letter 95-05 Probability of Detection Methodology for 90-Day Report, December 2020.
- 11. Watts Bar Unit 2 Technical Specification, TS 5.7.2.12.2
- 12. USNRC Report, Watts Bar Nuclear Plant, Unit 2 - Issuance of Amendment No. 48 Regarding Use of Alternate Probability of Detection Values for Beginning of Cycle in Support of Operational Assessment (EPID L-2020-LLA-0273), February 2021. (ADAMS Accession No. ML21027A167)
- This record was final approved on 2/10/2021 3:23:04 PM. (This statement was added by the PRIME system upon its validation)
WESTINGHOUSE NON-PROPRIETARY CLASS 3 8-2 SG-CDMP-21-1-NP February 2021 Revision 0
Subject:
GL 95-05 PORV Setpoint, November 9, 2020. (Attached in EDMS)
- 14. NRC Notification of Exceeding CM NRC Event Notification from TVA No. 54994, Notification of Steam Generator Tube Degradation, November 2020.
- This record was final approved on 2/10/2021 3:23:04 PM. (This statement was added by the PRIME system upon its validation)
WESTINGHOUSE NON-PROPRIETARY CLASS 3 A-1 SG-CDMP-21-1-NP February 2021 Revision 0 APPENDIX A Table A-1 SG-1 U2R3 DSI Indications SG Row Col Volts Location Comments SAI/MAI NDF PLUG 1
1 6
0.98 H03 SAI 1
2 6
0.41 H06 1
2 10 0.61 H03 1
2 17 0.49 H05 1
2 19 0.36 H04 1
2 25 0.47 H03 1
2 26 0.52 H04 1
2 34 0.71 H04 1
2 38 0.76 H04 NDF 1
2 44 0.57 H03 1
3 20 0.35 H06 1
3 61 0.41 H02 1
3 95 0.48 H04 1
3 112 0.39 H03 1
4 14 0.75 H04 NDF 1
4 21 0.49 H03 NDF 1
4 21 0.93 H04 NDF 1
4 23 0.68 H05 1
4 24 1.06 H04 NDF 1
4 25 0.83 H04 NDF 1
4 25 0.58 H05 NDF 1
4 27 0.74 H03 1
4 29 0.62 H04 1
4 30 0.81 H04 NDF 1
4 30 0.8 H05 NDF 1
4 32 0.99 H04 NDF 1
4 35 0.76 H04 NDF 1
4 37 0.63 H04 1
4 37 0.27 H05 1
4 40 0.47 H07 1
4 41 0.86 H04 NDF 1
4 41 0.78 H05 NDF 1
4 42 1.15 H04 NDF 1
4 43 0.9 H04 NDF 1
4 43 0.77 H05 NDF 1
4 43 0.64 H06 NDF 1
4 46 0.51 H02 1
4 47 0.43 H05
- This record was final approved on 2/10/2021 3:23:04 PM. (This statement was added by the PRIME system upon its validation)
WESTINGHOUSE NON-PROPRIETARY CLASS 3 A-2 SG-CDMP-21-1-NP February 2021 Revision 0 Table A-1 SG-1 U2R3 DSI Indications SG Row Col Volts Location Comments SAI/MAI NDF PLUG 1
4 48 1.11 H04 NDF 1
4 49 0.63 H02 NDF 1
4 49 1.23 H04 NDF 1
4 49 0.61 H05 NDF 1
4 49 0.87 H06 NDF 1
4 50 0.88 H02 SAI 1
4 50 1.09 H04 NDF 1
4 51 1.23 H04 NDF 1
4 53 0.74 H04 1
4 57 0.53 H02 PLG 1
4 57 0.71 H03 PLG 1
4 65 1.14 H04 NDF PLG 1
4 65 0.71 H05 NDF PLG 1
4 75 1.32 H04 NDF 1
4 83 1.01 H05 NDF 1
4 85 0.44 H05 1
4 89 0.95 H04 NDF 1
4 91 0.68 H03 1
4 91 0.62 H04 1
4 92 0.7 H04 1
4 95 0.47 H05 1
4 96 0.48 H05 1
4 107 0.66 H04 1
4 113 0.56 H06 1
5 8
0.93 H04 SAI 1
5 10 0.77 H03 SAI 1
5 26 0.36 H06 1
5 43 0.87 H04 NDF 1
5 47 0.97 H04 NDF 1
5 48 1.12 H04 NDF 1
6 10 0.38 H06 1
6 13 0.66 H04 1
6 19 0.61 H03 1
6 38 0.82 H02 SAI 1
6 63 0.27 H05 1
6 66 0.83 H04 NDF 1
6 89 0.58 H02 1
6 99 0.65 H02 1
6 103 0.63 H02 1
6 106 0.78 H02 SAI
- This record was final approved on 2/10/2021 3:23:04 PM. (This statement was added by the PRIME system upon its validation)
WESTINGHOUSE NON-PROPRIETARY CLASS 3 A-3 SG-CDMP-21-1-NP February 2021 Revision 0 Table A-1 SG-1 U2R3 DSI Indications SG Row Col Volts Location Comments SAI/MAI NDF PLUG 1
6 107 1.38 H02 NDF 1
6 109 0.56 H05 1
7 11 0.75 H04 MAI 1
7 12 0.93 H04 SAI 1
7 18 0.87 H02 SAI 1
7 20 0.3 H06 1
7 30 0.48 H05 1
7 43 1.29 H04 NDF 1
7 46 0.48 H05 1
7 105 0.66 H02 1
7 107 1.21 H02 SAI PLG 1
8 24 0.75 H03 NDF 1
8 44 0.38 H02 SAI 1
8 49 0.7 H04 1
8 67 0.44 H03 1
8 89 0.54 H02 1
9 20 0.35 H06 1
9 26 1.19 H03 NDF 1
9 32 0.71 H03 1
9 61 0.36 H05 1
9 70 0.95 H04 NDF 1
9 70 0.49 H06 NDF 1
9 106 0.58 H05 1
10 16 0.47 H06 1
10 41 0.41 H03 1
11 5
0.35 H05 1
11 9
0.51 H06 1
11 46 0.21 H07 1
11 59 0.24 H03 1
12 13 0.27 H05 1
12 45 0.45 H02 SAI 1
12 72 0.84 H02 SAI 1
12 87 0.48 H03 1
13 38 1.1 H04 NDF 1
13 44 0.79 H02 NDF 1
13 44 0.61 H03 NDF 1
13 44 0.24 H06 NDF 1
13 94 0.39 H05 1
14 44 0.58 H02 1
14 49 0.58 H03
- This record was final approved on 2/10/2021 3:23:04 PM. (This statement was added by the PRIME system upon its validation)
WESTINGHOUSE NON-PROPRIETARY CLASS 3 A-4 SG-CDMP-21-1-NP February 2021 Revision 0 Table A-1 SG-1 U2R3 DSI Indications SG Row Col Volts Location Comments SAI/MAI NDF PLUG 1
14 50 0.57 H03 1
14 68 0.32 H03 1
14 68 0.53 H05 1
14 82 0.78 H02 NDF 1
15 4
0.47 H06 1
15 8
0.42 H03 1
15 49 0.65 H03 1
15 60 0.65 H03 1
16 8
0.58 H05 1
16 11 0.23 H07 1
16 12 0.31 H07 1
16 40 0.5 H03 1
16 49 0.57 H03 1
16 60 0.67 H03 1
16 60 0.67 H04 1
16 62 0.65 H05 1
16 106 0.8 H05 NDF 1
17 17 0.5 H03 1
17 18 0.37 H02 1
17 18 0.5 H05 1
17 34 0.41 H03 1
17 39 1.11 H04 NDF 1
17 44 0.5 H04 1
17 45 0.47 H02 1
17 50 0.56 H03 1
17 70 0.28 H07 1
17 94 0.76 H02 SAI 1
18 18 0.6 H03 1
18 21 0.38 H05 1
18 23 0.92 H03 SAI NDF 1
18 32 0.67 H02 1
18 42 0.94 H02 MAI 1
18 42 0.73 H03 NDF 1
18 46 0.33 H03 1
18 64 0.32 H05 1
19 40 0.36 H06 1
19 42 0.67 H02 1
19 45 0.47 H03 1
19 67 0.81 H03 NDF 1
20 14 0.42 H03
- This record was final approved on 2/10/2021 3:23:04 PM. (This statement was added by the PRIME system upon its validation)
WESTINGHOUSE NON-PROPRIETARY CLASS 3 A-5 SG-CDMP-21-1-NP February 2021 Revision 0 Table A-1 SG-1 U2R3 DSI Indications SG Row Col Volts Location Comments SAI/MAI NDF PLUG 1
20 15 0.29 H05 1
20 45 0.34 C09 NDF 1
20 67 0.56 H05 1
20 80 0.8 H03 NDF 1
21 15 0.29 H02 1
22 45 0.31 H05 1
22 66 0.61 H05 1
22 69 0.54 H05 1
23 10 0.42 H02 1
23 51 0.53 H02 SAI 1
24 27 0.35 H03 1
24 45 0.3 H06 1
24 108 0.84 H03 SAI 1
25 14 0.6 H03 1
26 41 0.68 H04 1
26 105 0.12 H03 1
27 9
0.3 H07 1
28 15 0.32 H03 1
30 10 0.38 H03 1
30 46 0.31 H03 1
30 93 0.64 H02 1
31 68 0.6 H03 1
32 12 0.32 H05 1
32 96 0.35 C14 1
33 16 0.3 H02 SAI 1
33 35 0.49 H03 SAI 1
34 17 0.64 H03 SAI 1
34 20 0.38 H03 1
34 21 0.63 H03 1
34 96 0.45 H02 1
37 46 0.65 H03 1
38 21 0.48 H05 1
38 21 0.51 H05 1
38 25 0.39 C10 NDF 1
40 23 0.57 H03 1
41 30 0.39 H03 1
41 39 1.66 H03 MAI PLG 1
41 73 0.29 C14 1
42 33 0.4 H02 SAI 1
43 49 0.44 H04
- This record was final approved on 2/10/2021 3:23:04 PM. (This statement was added by the PRIME system upon its validation)
WESTINGHOUSE NON-PROPRIETARY CLASS 3 A-6 SG-CDMP-21-1-NP February 2021 Revision 0 Table A-1 SG-1 U2R3 DSI Indications SG Row Col Volts Location Comments SAI/MAI NDF PLUG 1
44 26 1.15 H02 SAI PLG 1
46 76 0.44 H03
- This record was final approved on 2/10/2021 3:23:04 PM. (This statement was added by the PRIME system upon its validation)
WESTINGHOUSE NON-PROPRIETARY CLASS 3 A-7 SG-CDMP-21-1-NP February 2021 Revision 0 Table A-2 SG-2 U2R3 DSI Indications SG Row Col Volts Location Comments SAI/MAI NDF PLUG 2
1 9
0.53 H03 2
1 13 0.3 H02 2
1 53 0.51 H03 2
1 55 0.31 H03 2
1 59 0.36 H03 2
1 79 0.52 H06 2
2 8
0.88 H03 SAI 2
2 24 0.52 H03 2
2 28 1.04 H03 SAI PLG 2
2 47 0.72 H02 SAI 2
2 49 1.48 H03 SAI PLG 2
3 8
0.47 H03 2
3 9
0.43 H03 2
3 54 0.88 H03 NDF 2
3 55 0.69 H03 2
3 57 0.76 H02 NDF 2
3 60 0.62 H02 2
3 61 0.42 H02 2
3 69 0.71 H02 2
4 21 0.4 H03 2
4 26 0.37 H03 2
4 27 0.48 H03 2
4 31 1.17 H02 SAI PLG 2
4 55 0.49 H03 2
4 59 0.7 H02 2
4 69 0.57 H02 SAI 2
4 77 0.51 H06 2
4 78 0.5 H06 2
4 90 0.99 H02 NDF 2
4 92 0.84 H02 NDF 2
5 14 0.43 H04 NDF 2
5 16 0.5 H03 NDF 2
5 50 0.99 H03 SAI 2
5 63 0.4 H06 2
5 67 0.62 H02 2
5 67 0.57 H03 2
5 69 0.49 H02 NDF 2
5 69 0.88 H03 NDF 2
5 88 0.91 H02 NDF 2
5 89 0.97 H02 NDF
- This record was final approved on 2/10/2021 3:23:04 PM. (This statement was added by the PRIME system upon its validation)
WESTINGHOUSE NON-PROPRIETARY CLASS 3 A-8 SG-CDMP-21-1-NP February 2021 Revision 0 Table A-2 SG-2 U2R3 DSI Indications SG Row Col Volts Location Comments SAI/MAI NDF PLUG 2
5 94 0.73 H08 2
6 4
0.71 H05 NDF 2
6 10 0.61 H05 NDF 2
6 12 0.52 H05 NDF 2
6 58 0.66 H03 NDF 2
6 58 0.81 H04 NDF 2
6 89 0.57 H02 2
6 91 0.69 H02 2
7 4
0.2 H05 2
7 9
0.35 H05 2
7 11 0.35 H05 2
7 14 0.41 H08 NDF 2
7 20 0.56 H02 NDF 2
7 23 0.4 H03 2
7 32 1.1 H02 NDF 2
7 32 0.39 H06 NDF 2
7 34 0.7 H03 2
7 44 1.56 H02 SAI PLG 2
7 48 0.57 H03 2
7 51 0.24 H08 2
7 57 0.5 H04 2
7 62 0.49 H07 2
7 64 0.61 H03 2
7 70 0.29 H02 2
7 73 0.77 H03 NDF 2
7 76 0.68 H03 2
7 76 0.74 H06 2
7 77 0.88 H02 NDF 2
7 77 0.39 H06 NDF 2
7 88 0.49 H03 2
7 89 0.47 H03 2
7 90 0.63 H02 2
7 91 0.85 H03 NDF 2
7 92 0.79 H02 NDF 2
7 93 0.78 H02 SAI 2
7 98 0.34 H03 2
7 99 0.97 H02 NDF 2
7 102 0.84 H02 NDF 2
7 102 0.32 H07 NDF 2
8 38 0.47 H04
- This record was final approved on 2/10/2021 3:23:04 PM. (This statement was added by the PRIME system upon its validation)
WESTINGHOUSE NON-PROPRIETARY CLASS 3 A-9 SG-CDMP-21-1-NP February 2021 Revision 0 Table A-2 SG-2 U2R3 DSI Indications SG Row Col Volts Location Comments SAI/MAI NDF PLUG 2
8 57 0.55 H05 2
8 61 0.64 H05 2
8 102 1.04 H02 NDF 2
8 105 0.68 H02 2
9 2
0.6 H05 NDF 2
9 23 0.93 H02 NDF 2
9 47 0.78 H02 NDF 2
9 48 0.84 H03 NDF 2
9 50 0.53 H05 2
9 52 1.16 H04 NDF 2
9 52 0.5 H05 NDF 2
9 66 0.64 H03 2
9 75 0.4 H03 2
9 80 0.62 H05 2
9 91 0.45 H05 2
9 104 0.91 H02 NDF 2
9 106 0.38 H08 2
10 3
0.63 H03 2
10 10 0.53 H05 NDF 2
10 30 0.65 H04 2
10 58 0.42 H02 2
10 58 0.63 H04 2
10 61 0.63 H04 2
11 7
0.51 H04 2
11 9
0.62 H05 2
11 9
0.32 H06 2
11 21 1.38 H02 NDF 2
11 57 1.16 H02 NDF 2
11 77 0.49 H02 2
11 87 0.94 H03 SAI 2
11 111 1.27 H02 NDF 2
11 111 0.85 H03 NDF 2
11 112 1.21 H02 NDF 2
11 112 0.87 H03 NDF 2
11 113 0.88 H03 NDF 2
12 36 0.29 H03 2
12 38 0.26 C08 NDF 2
12 50 0.55 H02 NDF 2
12 50 1.25 H04 NDF 2
14 9
0.41 H05
- This record was final approved on 2/10/2021 3:23:04 PM. (This statement was added by the PRIME system upon its validation)
WESTINGHOUSE NON-PROPRIETARY CLASS 3 A-10 SG-CDMP-21-1-NP February 2021 Revision 0 Table A-2 SG-2 U2R3 DSI Indications SG Row Col Volts Location Comments SAI/MAI NDF PLUG 2
14 14 0.49 H07 NDF 2
14 27 1
H04 NDF 2
14 36 1.02 H02 NDF 2
14 44 0.42 H03 SAI 2
14 52 1.67 H03 NDF 2
14 53 0.83 H03 SAI 2
14 87 0.33 H02 SAI NDF 2
15 24 0.32 H03 SAI 2
15 24 0.43 H05 NDF 2
15 57 0.7 H02 2
15 108 0.87 H03 NDF 2
15 111 0.69 H02 2
15 111 0.66 H03 2
16 5
0.23 H03 SAI 2
16 9
0.81 H05 NDF 2
16 12 0.64 H05 NDF 2
16 21 0.29 H05 2
16 22 0.49 H05 NDF 2
16 33 0.42 H02 2
16 38 0.72 H03 2
16 39 0.58 H05 2
16 42 1.4 H05 NDF 2
16 43 0.74 H03 2
16 44 0.84 H03 SAI 2
16 44 0.5 H05 NDF 2
16 44 0.47 H06 NDF 2
16 46 1
H06 NDF 2
16 54 0.52 H05 2
16 65 0.65 H03 2
16 71 0.41 H08 2
16 90 0.7 H02 2
16 94 0.59 H02 2
16 97 0.76 H05 NDF 2
16 98 0.86 H03 NDF 2
16 101 0.76 H03 NDF 2
17 13 1.44 H02 MAI PLG 2
17 14 0.62 H02 SAI 2
17 16 0.6 H04 NDF 2
17 22 0.58 H02 SAI 2
17 88 0.84 H02 NDF
- This record was final approved on 2/10/2021 3:23:04 PM. (This statement was added by the PRIME system upon its validation)
WESTINGHOUSE NON-PROPRIETARY CLASS 3 A-11 SG-CDMP-21-1-NP February 2021 Revision 0 Table A-2 SG-2 U2R3 DSI Indications SG Row Col Volts Location Comments SAI/MAI NDF PLUG 2
17 88 0.47 H05 NDF 2
17 89 0.92 H02 NDF 2
17 89 0.89 H03 NDF 2
17 91 0.85 H02 NDF 2
17 92 0.33 H03 2
17 101 0.91 H02 NDF 2
17 111 0.95 H02 NDF 2
18 28 0.32 H06 2
18 38 0.42 H07 2
18 45 0.34 H08 2
18 48 0.51 H04 2
18 57 0.57 H02 2
19 33 0.47 H03 2
19 60 0.43 H06 2
19 61 0.96 H04 NDF 2
19 62 1.22 H02 SAI PLG 2
19 64 1.02 H02 NDF 2
19 64 0.26 H03 NDF 2
19 66 0.91 H04 NDF 2
19 67 1.18 H05 NDF 2
19 105 0.97 H04 NDF 2
19 106 0.45 H03 2
19 108 0.21 H07 2
20 36 0.25 H06 2
20 38 0.33 H06 2
20 38 0.5 H08 2
20 56 0.25 H02 2
20 58 0.31 H05 2
20 93 0.52 H03 2
20 102 1.06 H03 SAI PLG 2
20 105 0.56 H03 2
21 36 0.39 H06 2
22 15 0.2 H02 2
22 46 0.77 H04 SAI 2
22 61 0.27 H04 2
22 94 1.32 H02 SAI PLG 2
23 82 0.28 H03 2
23 84 0.45 H03 2
23 95 0.51 H03 2
23 100 0.49 H03
- This record was final approved on 2/10/2021 3:23:04 PM. (This statement was added by the PRIME system upon its validation)
WESTINGHOUSE NON-PROPRIETARY CLASS 3 A-12 SG-CDMP-21-1-NP February 2021 Revision 0 Table A-2 SG-2 U2R3 DSI Indications SG Row Col Volts Location Comments SAI/MAI NDF PLUG 2
23 109 0.66 H03 2
24 49 0.46 H02 2
24 63 0.33 H03 2
24 89 0.49 H05 2
24 99 0.79 H02 SAI 2
25 16 0.55 H04 NDF 2
25 90 0.66 H03 2
25 104 0.54 H03 2
25 108 0.63 H02 2
25 108 0.73 H03 SAI 2
26 14 0.38 C13 NDF 2
26 31 0.54 H02 2
26 49 0.53 H04 2
26 61 0.87 H02 SAI 2
26 65 1.26 H04 NDF 2
26 104 2.05 H03 SAI PLG 2
27 39 0.66 H02 2
27 48 0.27 H08 2
27 67 1.35 H04 SAI PLG 2
28 11 0.33 H06 2
28 23 0.22 H06 2
28 29 0.92 H02 NDF 2
28 52 0.14 H04 2
28 62 0.71 H06 2
28 64 0.65 H03 2
28 65 0.41 H03 2
28 75 1.82 H04 NDF 2
29 19 0.38 H05 2
29 77 0.59 H03 2
29 79 0.7 H04 2
29 91 0.49 H02 NDF 2
29 91 0.62 H03 SAI 2
29 94 0.75 H02 NDF 2
29 94 0.37 H03 NDF 2
29 94 0.45 H05 NDF 2
29 103 1.06 H03 MAI PLG 2
30 34 0.51 H02 2
30 78 1.41 H02 SAI PLG 2
30 78 0.83 H03 SAI PLG 2
30 78 0.34 H04 SAI PLG
- This record was final approved on 2/10/2021 3:23:04 PM. (This statement was added by the PRIME system upon its validation)
WESTINGHOUSE NON-PROPRIETARY CLASS 3 A-13 SG-CDMP-21-1-NP February 2021 Revision 0 Table A-2 SG-2 U2R3 DSI Indications SG Row Col Volts Location Comments SAI/MAI NDF PLUG 2
30 78 0.59 H05 SAI PLG 2
30 81 0.56 H05 2
30 99 0.44 H03 2
31 34 0.34 H03 2
31 56 0.3 H02 2
31 59 0.14 H04 2
31 61 0.26 H02 2
31 62 0.38 H04 2
31 65 0.8 H02 NDF 2
31 65 0.39 H04 NDF 2
31 72 0.92 H02 MAI 2
31 73 1.13 H02 SAI PLG 2
31 96 0.56 H03 2
31 100 0.74 H03 2
33 50 0.16 H03 2
33 51 0.36 H02 2
33 51 0.4 H03 2
33 61 0.35 H03 2
33 99 0.38 H02 2
34 90 0.81 H03 NDF 2
35 36 0.38 H04 2
36 61 0.75 H02 MAI 2
36 63 0.17 H03 2
36 67 0.19 H08 2
36 73 0.68 H04 2
37 74 0.73 H03 2
38 65 0.3 H03 SAI 2
38 76 0.71 H02 2
39 62 0.47 H02 2
39 71 0.28 H02 2
39 71 0.24 H03 2
39 75 0.73 H02 2
39 80 0.77 H02 MAI 2
39 80 0.41 H03 SAI 2
39 85 1.24 H04 NDF 2
40 53 0.76 H02 MAI PLG 2
40 53 3.82 H03 SAI PLG 2
41 38 0.44 H06 2
42 38 0.25 H03 2
42 44 0.47 H02
- This record was final approved on 2/10/2021 3:23:04 PM. (This statement was added by the PRIME system upon its validation)
WESTINGHOUSE NON-PROPRIETARY CLASS 3 A-14 SG-CDMP-21-1-NP February 2021 Revision 0 Table A-2 SG-2 U2R3 DSI Indications SG Row Col Volts Location Comments SAI/MAI NDF PLUG 2
42 62 1.64 H03 SAI PLG 2
42 87 0.38 H03 2
43 55 0.42 H03 2
43 56 0.58 H03 SAI 2
43 73 0.4 H02 2
43 73 0.35 H04 2
43 74 0.71 H02 2
43 81 0.69 H02 2
43 82 0.86 H03 SAI 2
43 82 0.63 H04 NDF 2
43 85 0.82 H02 NDF 2
43 85 0.25 H03 NDF 2
43 87 0.23 H04 2
44 52 1.75 H03 MAI PLG 2
44 55 0.59 H03 2
44 66 1.24 H02 SAI PLG 2
44 82 0.85 H02 SAI 2
44 84 0.6 H02 2
45 65 0.99 H02 MAI PLG 2
46 43 0.37 H02 2
46 73 0.52 H03 2
46 73 0.44 H04 2
46 85 0.87 H03 NDF 2
47 60 0.45 H02 2
47 73 0.31 H02 2
47 75 0.45 H03 2
47 79 0.31 H03 2
47 81 0.56 H02 2
47 81 0.59 H03 2
47 83 0.48 H02 2
48 30 1.36 H02 NDF 2
48 37 0.51 H02 2
49 35 0.47 H02 2
49 82 0.71 H02
- This record was final approved on 2/10/2021 3:23:04 PM. (This statement was added by the PRIME system upon its validation)
WESTINGHOUSE NON-PROPRIETARY CLASS 3 A-15 SG-CDMP-21-1-NP February 2021 Revision 0 Table A-3 SG-3 U2R3 DSI Indications SG Row Col Volts Location Comments SAI/MAI NDF PLUG 3
2 23 0.43 H04 3
2 26 0.52 H04 3
2 27 0.73 H04 3
2 109 0.39 H02 3
2 112 1.81 H03 SAI PLG 3
2 113 0.71 H03 3
3 46 0.91 H03 NDF 3
3 92 1.13 H02 SAI PLG 3
3 107 0.69 H02 3
3 109 0.91 H02 SAI 3
4 51 0.85 H04 SAI 3
4 90 0.64 H02 3
4 99 0.77 H02 MAI 3
4 99 0.58 H03 NDF 3
4 104 0.56 H02 3
4 106 0.3 H02 3
4 109 2.26 H02 SAI PLG 3
4 109 3.64 H03 SAI PLG 3
4 109 0.64 H04 NDF PLG 3
5 20 0.84 H02 NDF 3
5 20 0.68 H04 NDF 3
5 21 0.75 H02 NDF 3
5 24 0.58 H02 3
5 25 1.01 H02 SAI PLG 3
5 25 0.5 H06 NDF PLG 3
5 26 1.28 H02 NDF 3
5 28 0.98 H02 MAI 3
5 28 0.86 H04 NDF 3
5 29 0.78 H03 SAI 3
5 29 0.76 H04 NDF 3
5 33 0.71 H02 3
5 34 0.59 H02 3
5 44 0.55 H04 3
5 47 0.63 H04 3
5 51 0.69 H03 SAI PLG 3
5 51 1.16 H04 MAI PLG 3
5 53 0.51 H04 3
5 55 0.76 H02 SAI 3
5 57 0.55 H04
- This record was final approved on 2/10/2021 3:23:04 PM. (This statement was added by the PRIME system upon its validation)
WESTINGHOUSE NON-PROPRIETARY CLASS 3 A-16 SG-CDMP-21-1-NP February 2021 Revision 0 Table A-3 SG-3 U2R3 DSI Indications SG Row Col Volts Location Comments SAI/MAI NDF PLUG 3
5 86 1
H03 NDF 3
5 91 0.35 H03 3
5 93 0.5 H05 3
5 94 0.63 H05 3
5 95 0.61 H02 3
5 95 0.65 H03 3
5 106 0.55 H02 SAI PLG 3
5 106 2.67 H03 SAI PLG 3
5 107 2.12 H02 MAI PLG 3
5 107 0.66 H03 SAI PLG 3
5 110 0.35 H04 3
6 44 1.59 H02 NDF 3
6 53 0.51 H04 3
6 76 0.65 H04 3
6 80 0.77 H04 NDF 3
6 84 1.13 H04 NDF 3
6 84 0.92 H05 NDF 3
6 85 0.46 H02 3
6 88 0.43 H02 3
6 91 1.09 H02 SAI PLG 3
6 95 0.88 H02 NDF 3
6 95 0.3 H04 NDF 3
7 35 0.44 H04 3
7 36 0.42 H04 3
7 47 0.99 H02 NDF 3
7 55 0.53 H02 3
7 60 1.27 H03 MAI PLG 3
7 62 3.83 H02 SAI PLG 3
7 69 0.59 H02 3
7 84 0.55 H05 3
7 87 0.34 H04 3
7 88 0.7 H04 3
7 95 0.34 H02 3
7 107 1.97 H03 SAI PLG 3
7 112 1.75 H02 SAI PLG 3
8 14 0.53 H02 3
8 22 0.52 H05 3
8 38 0.53 H04 3
8 39 1.2 H03 NDF 3
8 46 1.43 H02 SAI PLG
- This record was final approved on 2/10/2021 3:23:04 PM. (This statement was added by the PRIME system upon its validation)
WESTINGHOUSE NON-PROPRIETARY CLASS 3 A-17 SG-CDMP-21-1-NP February 2021 Revision 0 Table A-3 SG-3 U2R3 DSI Indications SG Row Col Volts Location Comments SAI/MAI NDF PLUG 3
8 51 1.04 H02 NDF 3
8 53 1.24 H03 MAI PLG 3
8 53 0.54 H04 SAI PLG 3
8 55 1.18 H02 SAI PLG 3
8 65 0.91 H03 MAI 3
8 69 0.37 H02 3
8 92 2.73 H02 SAI PLG 3
8 96 0.74 H02 3
9 4
0.42 H02 3
9 9
2.95 H02 SAI PLG 3
9 12 0.87 H02 NDF 3
9 19 0.28 H05 3
9 37 0.56 H02 SAI 3
9 37 0.85 H04 NDF 3
9 40 0.85 H02 NDF 3
9 46 0.51 H03 3
9 49 0.81 H02 MAI 3
9 53 0.59 H03 3
9 59 0.4 H05 3
9 62 0.61 H02 3
9 64 0.69 H02 NDF 3
9 64 0.98 H05 NDF 3
9 73 1.51 H03 SAI PLG 3
9 83 0.6 H04 3
9 88 0.68 H04 3
9 98 1.32 H02 MAI PLG 3
9 98 0.73 H03 MAI PLG 3
9 102 0.4 H02 3
9 103 0.54 H02 3
10 18 0.44 H02 3
10 25 0.72 H04 3
10 31 0.79 H04 NDF 3
10 35 0.8 H02 NDF 3
10 35 0.59 H05 NDF 3
10 37 0.94 H02 NDF 3
10 38 0.91 H05 NDF 3
10 41 0.94 H02 SAI 3
10 45 0.97 H05 NDF 3
10 47 0.94 H02 SAI 3
10 47 1.32 H03 NDF
- This record was final approved on 2/10/2021 3:23:04 PM. (This statement was added by the PRIME system upon its validation)
WESTINGHOUSE NON-PROPRIETARY CLASS 3 A-18 SG-CDMP-21-1-NP February 2021 Revision 0 Table A-3 SG-3 U2R3 DSI Indications SG Row Col Volts Location Comments SAI/MAI NDF PLUG 3
10 47 0.91 H04 SAI 3
10 60 0.5 H05 3
10 60 0.63 H07 3
10 64 0.62 H05 3
10 64 0.43 H06 3
10 90 0.51 H02 3
10 110 0.54 H04 3
10 110 0.68 H05 3
11 4
0.74 H05 3
11 6
1.12 H02 NDF 3
11 34 0.45 H02 3
11 44 0.45 H04 3
11 49 0.91 H02 NDF 3
11 55 0.71 H02 3
11 60 0.79 H02 NDF 3
11 62 0.62 H02 3
11 82 0.39 H02 3
11 109 1.83 H02 MAI PLG 3
11 109 1.04 H04 NDF PLG 3
11 110 0.72 H02 3
12 4
0.58 H05 3
12 41 0.79 H02 NDF 3
12 42 0.89 H03 NDF 3
12 42 1.02 H04 NDF 3
12 104 1.17 H02 MAI PLG 3
12 108 0.31 H02 3
12 109 0.57 H02 3
12 109 0.51 H05 3
12 111 8.03 H02 MAI PLG 3
12 113 0.66 H02 SAI NDF 3
13 20 0.78 H02 MAI 3
13 20 0.47 H03 MAI 3
13 20 0.65 H04 NDF 3
13 36 0.51 H08 3
13 38 0.42 H05 3
13 42 0.74 H02 MAI 3
13 42 0.84 H03 MAI 3
13 43 1.02 H02 SAI PLG 3
13 43 0.66 H03 SAI PLG 3
13 44 0.66 H04
- This record was final approved on 2/10/2021 3:23:04 PM. (This statement was added by the PRIME system upon its validation)
WESTINGHOUSE NON-PROPRIETARY CLASS 3 A-19 SG-CDMP-21-1-NP February 2021 Revision 0 Table A-3 SG-3 U2R3 DSI Indications SG Row Col Volts Location Comments SAI/MAI NDF PLUG 3
13 44 0.55 H05 3
13 46 0.72 H05 3
13 47 0.69 H05 3
13 49 0.5 H02 3
13 57 0.52 H05 3
13 59 0.51 H02 3
13 60 0.96 H03 MAI 3
13 71 1.15 H02 MAI PLG 3
13 71 1.61 H03 MAI PLG 3
13 73 0.73 H03 3
13 87 0.49 H03 3
13 88 0.5 H02 PLG 3
13 89 0.57 H04 3
13 109 0.47 H02 3
13 110 1.05 H02 MAI PLG 3
13 111 0.61 H02 3
13 111 0.53 H04 3
13 112 1.71 H02 SAI PLG 3
14 3
0.87 H02 SAI 3
14 3
0.54 H03 MAI 3
14 4
0.6 H04 3
14 7
4.83 H02 SAI PLG 3
14 9
0.98 H02 MAI 3
14 44 0.99 H03 NDF 3
14 44 0.63 H04 NDF 3
14 44 0.72 H05 NDF 3
14 49 1.3 H02 NDF 3
14 49 0.71 H05 NDF 3
14 66 0.47 H05 3
14 85 0.32 H02 3
14 86 0.43 H05 3
14 91 0.82 H02 SAI PLG 3
14 92 2.11 H02 MAI PLG 3
14 92 1.09 H03 NDF PLG 3
14 99 0.46 H02 PLG 3
14 101 0.73 H02 PLG 3
14 104 0.56 H02 3
14 105 0.28 H02 3
14 108 2.48 H02 MAI PLG 3
14 109 0.73 H02
- This record was final approved on 2/10/2021 3:23:04 PM. (This statement was added by the PRIME system upon its validation)
WESTINGHOUSE NON-PROPRIETARY CLASS 3 A-20 SG-CDMP-21-1-NP February 2021 Revision 0 Table A-3 SG-3 U2R3 DSI Indications SG Row Col Volts Location Comments SAI/MAI NDF PLUG 3
14 110 1.78 H02 MAI PLG 3
14 110 0.49 H04 NDF PLG 3
14 110 0.85 H05 NDF PLG 3
14 111 0.49 H02 SAI PLG 3
14 111 1.36 H03 MAI PLG 3
14 111 0.9 H04 NDF PLG 3
15 18 0.53 H04 3
15 29 0.53 H02 3
15 68 0.92 H02 SAI 3
15 82 0.62 H02 PLG 3
15 93 0.41 H07 3
16 37 0.93 H02 SAI 3
16 37 0.79 H03 SAI 3
16 40 1
H03 SAI 3
16 48 0.42 H02 3
16 49 1.3 H02 SAI PLG 3
16 49 1.31 H03 NDF PLG 3
16 49 0.82 H04 NDF PLG 3
16 71 0.7 H02 PLG 3
16 71 0.65 H04 PLG 3
16 74 0.68 H04 3
16 85 0.33 H05 3
16 111 1.38 H02 MAI PLG 3
17 5
1.59 H02 MAI PLG 3
17 9
0.49 H02 3
17 10 0.72 H02 3
17 12 0.76 H03 SAI 3
17 15 0.87 H02 MAI 3
17 24 1.67 H02 MAI PLG 3
17 24 0.58 H03 MAI PLG 3
17 37 1.41 H02 SAI PLG 3
17 37 1.34 H03 SAI PLG 3
17 38 0.98 H02 MAI 3
17 38 0.49 H03 SAI 3
17 39 0.47 H03 3
17 40 0.78 H02 SAI 3
17 40 0.8 H03 SAI 3
17 41 1.71 H02 MAI PLG 3
17 44 0.31 H01 SAI PLG 3
17 44 0.82 H02 MAI PLG
- This record was final approved on 2/10/2021 3:23:04 PM. (This statement was added by the PRIME system upon its validation)
WESTINGHOUSE NON-PROPRIETARY CLASS 3 A-21 SG-CDMP-21-1-NP February 2021 Revision 0 Table A-3 SG-3 U2R3 DSI Indications SG Row Col Volts Location Comments SAI/MAI NDF PLUG 3
17 46 6.87 H02 MAI PLG 3
17 47 5.13 H02 MAI PLG 3
17 47 0.92 H04 SAI PLG 3
17 54 9.35 H01 SAI PLG 3
17 54 0.64 H03 SAI PLG 3
17 55 0.87 H05 NDF 3
17 65 0.73 H02 MAI 3
17 65 0.79 H04 MAI 3
17 89 0.74 H04 3
17 98 0.6 H02 3
18 35 0.82 H02 SAI 3
18 92 1.4 H02 MAI PLG 3
18 92 0.77 H03 SAI PLG 3
18 92 0.53 H06 NDF PLG 3
18 94 1.04 H02 MAI PLG 3
18 94 0.36 H03 NDF PLG 3
18 94 0.31 H07 NDF PLG 3
18 101 2.66 H02 SAI PLG 3
18 106 0.58 H02 3
18 108 2.96 H02 MAI PLG 3
18 109 2.72 H02 MAI PLG 3
18 109 0.56 H04 NDF PLG 3
18 109 0.47 H06 NDF PLG 3
18 110 0.68 H02 MAI PLG 3
18 110 1.22 H03 MAI PLG 3
18 110 0.89 H04 NDF PLG 3
19 6
0.87 H05 NDF 3
19 8
0.81 H02 MAI 3
19 10 2.58 H02 MAI PLG 3
19 12 0.95 H02 MAI 3
19 14 0.57 H02 3
19 17 0.4 H02 3
19 45 0.58 H05 3
19 65 0.51 H02 3
19 88 0.86 H04 SAI 3
19 89 1.13 H02 MAI PLG 3
19 90 0.88 H02 MAI 3
19 90 0.52 H03 SAI 3
20 12 0.86 H02 MAI 3
20 21 0.84 H02 MAI
- This record was final approved on 2/10/2021 3:23:04 PM. (This statement was added by the PRIME system upon its validation)
WESTINGHOUSE NON-PROPRIETARY CLASS 3 A-22 SG-CDMP-21-1-NP February 2021 Revision 0 Table A-3 SG-3 U2R3 DSI Indications SG Row Col Volts Location Comments SAI/MAI NDF PLUG 3
20 78 1.13 H02 SAI PLG 3
21 9
1.14 H02 SAI PLG 3
21 21 0.63 H05 3
21 37 0.81 H02 MAI PLG 3
21 38 2.26 H02 MAI PLG 3
21 40 0.72 H06 3
21 48 0.68 H06 3
21 93 0.51 H02 3
21 106 1.22 H02 MAI PLG 3
21 106 1.19 H03 SAI PLG 3
21 106 0.75 H04 NDF PLG 3
22 63 0.96 H02 SAI 3
22 74 1.03 H03 MAI PLG 3
22 77 1.64 H02 MAI PLG 3
22 83 0.81 H02 SAI 3
23 9
0.63 H06 3
23 45 0.35 H05 3
23 74 0.59 H05 3
23 93 1.13 H02 SAI PLG 3
23 101 0.34 H04 3
23 106 0.44 H02 3
23 109 0.75 H02 SAI 3
25 11 0.62 H06 3
25 28 0.3 H01 SAI PLG 3
25 37 0.5 H06 3
25 42 0.58 H02 MAI 3
25 92 0.99 H02 NDF 3
25 94 1.22 H03 SAI PLG 3
25 96 1.02 H03 SAI PLG 3
25 98 0.54 H06 3
26 43 0.39 H05 3
26 59 0.7 H04 3
26 107 0.45 H02 3
27 8
0.41 H02 3
27 8
0.47 H04 3
27 19 0.56 H02 3
27 47 1.44 H02 MAI PLG 3
27 48 1.2 H02 MAI PLG 3
28 27 0.14 H02 MAI PLG 3
28 27 1.35 H03 MAI PLG
- This record was final approved on 2/10/2021 3:23:04 PM. (This statement was added by the PRIME system upon its validation)
WESTINGHOUSE NON-PROPRIETARY CLASS 3 A-23 SG-CDMP-21-1-NP February 2021 Revision 0 Table A-3 SG-3 U2R3 DSI Indications SG Row Col Volts Location Comments SAI/MAI NDF PLUG 3
28 37 0.25 H05 3
29 57 1.13 H02 MAI PLG 3
29 57 0.26 H04 SAI PLG 3
30 25 0.53 H02 3
30 99 0.47 H04 3
30 99 0.27 H07 3
31 27 0.5 H04 3
31 35 1.17 H04 NDF 3
31 96 0.32 H04 3
32 86 0.35 H04 3
33 81 1.58 H02 MAI PLG 3
33 102 0.64 H03 3
34 31 0.34 H05 3
35 18 2.62 H02 SAI PLG 3
35 25 1.21 H02 MAI PLG 3
37 65 2.16 H02 MAI PLG 3
37 72 0.29 H06 3
38 47 0.57 H04 3
38 56 1.29 H02 MAI PLG 3
38 59 1.69 H02 MAI PLG 3
38 59 0.41 H03 SAI PLG 3
40 50 0.72 H02 3
40 58 0.38 H04 3
40 64 0.98 H02 MAI PLG 3
40 64 0.41 H03 SAI PLG 3
40 64 0.5 H04 NDF PLG 3
41 70 0.47 H02 3
41 71 0.75 H02 SAI PLG 3
42 58 0.76 H02 MAI 3
42 58 0.38 H03 MAI 3
42 64 0.28 H02 3
42 76 0.6 H02 3
42 79 0.32 H03 3
43 57 0.66 H02 3
43 58 0.67 H03 3
43 62 0.51 H03 3
43 69 0.48 H02 3
43 70 0.4 H02 3
43 77 0.74 H02 3
43 78 0.3 H02
- This record was final approved on 2/10/2021 3:23:04 PM. (This statement was added by the PRIME system upon its validation)
WESTINGHOUSE NON-PROPRIETARY CLASS 3 A-24 SG-CDMP-21-1-NP February 2021 Revision 0 Table A-3 SG-3 U2R3 DSI Indications SG Row Col Volts Location Comments SAI/MAI NDF PLUG 3
44 54 0.45 H05 3
44 56 0.49 H04 3
44 65 0.39 H06 3
44 79 0.49 H02 3
44 80 0.55 H02 3
44 80 0.47 H03 3
44 87 0.39 H02 3
45 31 0.65 H02 3
45 35 0.44 H03 3
45 47 1.53 H02 SAI PLG 3
45 50 1.73 H02 MAI PLG 3
45 54 1.78 H02 MAI PLG 3
45 54 0.36 H04 NDF PLG 3
46 53 0.99 C06 NDF 3
46 54 1.9 H02 MAI PLG 3
46 54 0.67 H04 MAI PLG 3
46 56 0.69 H02 3
46 57 0.7 H02 3
46 75 0.65 H03 3
46 76 0.97 H02 MAI 3
46 79 1.19 H03 MAI PLG 3
46 85 0.7 H02 NDF 3
46 86 0.81 H02 NDF 3
46 87 1.42 H02 SAI PLG 3
46 88 2.01 H02 NDF 3
46 89 2.2 H02 NDF 3
47 59 0.55 H02 3
47 85 0.92 H03 MAI 3
47 86 0.91 H02 MAI 3
47 87 1.5 H02 SAI PLG 3
48 47 0.2 H07 3
48 50 0.63 H02 3
48 52 1.06 H02 SAI PLG 3
48 57 3.21 H02 MAI PLG 3
48 72 0.6 H02 3
48 86 1.09 H02 NDF 3
49 46 0.28 H02 SAI 3
49 58 1.73 C05 NDF 3
49 73 0.34 H02 3
49 74 0.41 H04
- This record was final approved on 2/10/2021 3:23:04 PM. (This statement was added by the PRIME system upon its validation)
WESTINGHOUSE NON-PROPRIETARY CLASS 3 A-25 SG-CDMP-21-1-NP February 2021 Revision 0 Table A-3 SG-3 U2R3 DSI Indications SG Row Col Volts Location Comments SAI/MAI NDF PLUG 3
49 76 0.42 H04
- This record was final approved on 2/10/2021 3:23:04 PM. (This statement was added by the PRIME system upon its validation)
WESTINGHOUSE NON-PROPRIETARY CLASS 3 A-26 SG-CDMP-21-1-NP February 2021 Revision 0 Table A-4 SG-4 U2R3 DSI Indications SG Row Col Volts Location Comments SAI/MAI NDF PLUG 4
1 58 0.62 H02 4
2 55 0.22 H02 4
2 59 0.47 H02 4
2 59 0.44 H03 4
2 60 0.53 H02 4
2 92 0.3 H03 4
2 103 0.55 H03 4
2 109 0.28 H03 4
3 7
1.01 H04 NDF 4
3 7
1.15 H05 NDF 4
3 9
0.61 H03 4
3 13 0.6 H03 4
3 65 0.45 H02 4
3 105 0.49 H03 4
4 5
0.44 H03 4
4 6
0.33 H04 4
4 11 0.71 H03 4
4 21 1.48 H02 SAI PLG 4
4 21 0.34 H03 NDF PLG 4
4 21 0.27 H04 NDF PLG 4
4 24 0.74 H04 4
4 32 0.24 H04 4
4 40 0.65 H02 4
4 43 0.83 H04 NDF 4
4 50 0.7 H02 4
4 81 0.86 H02 NDF 4
4 83 0.72 H02 4
4 97 0.63 H03 4
4 98 0.92 H02 NDF 4
4 99 0.69 H02 4
4 101 0.4 H02 4
4 102 0.5 H02 4
4 110 0.5 H03 4
4 112 0.72 H03 4
5 1
0.68 H02 4
5 2
0.66 H02 4
5 4
0.43 H03 4
5 5
0.6 H05 4
5 15 0.87 H02 NDF
- This record was final approved on 2/10/2021 3:23:04 PM. (This statement was added by the PRIME system upon its validation)
WESTINGHOUSE NON-PROPRIETARY CLASS 3 A-27 SG-CDMP-21-1-NP February 2021 Revision 0 Table A-4 SG-4 U2R3 DSI Indications SG Row Col Volts Location Comments SAI/MAI NDF PLUG 4
5 15 0.69 H03 SAI 4
5 16 0.54 H02 4
5 16 0.64 H05 4
5 17 0.94 H02 NDF 4
5 17 0.52 H03 SAI 4
5 17 0.42 H04 SAI 4
5 19 0.73 H03 4
5 21 0.71 H02 4
5 28 0.69 H04 4
5 54 0.49 H02 4
5 62 1.02 H03 SAI PLG 4
5 64 0.47 H06 4
5 70 1
H02 NDF 4
5 72 0.67 H03 4
5 74 1.23 H03 NDF 4
5 76 0.44 H03 SAI NDF PLG 4
5 79 0.77 H02 NDF 4
5 79 0.39 H04 NDF 4
5 80 0.94 H02 NDF 4
5 80 0.47 H03 NDF 4
5 80 0.81 H04 NDF 4
5 80 0.33 H06 NDF 4
5 81 0.48 H04 4
5 82 0.71 H02 4
5 83 0.41 H02 NDF 4
5 83 0.83 H03 NDF 4
5 86 0.53 H02 4
5 92 0.38 C09 NDF 4
5 92 0.44 H02 4
5 97 0.52 H02 4
5 100 0.73 H03 4
5 103 0.55 H02 4
5 108 0.51 H03 4
6 1
0.78 H02 NDF 4
6 2
0.77 H02 NDF 4
6 3
0.77 H02 MAI 4
6 3
0.45 H03 SAI 4
6 4
0.76 H02 SAI 4
6 4
0.39 H05 NDF 4
6 6
0.86 H02 NDF
- This record was final approved on 2/10/2021 3:23:04 PM. (This statement was added by the PRIME system upon its validation)
WESTINGHOUSE NON-PROPRIETARY CLASS 3 A-28 SG-CDMP-21-1-NP February 2021 Revision 0 Table A-4 SG-4 U2R3 DSI Indications SG Row Col Volts Location Comments SAI/MAI NDF PLUG 4
6 6
0.78 H05 NDF 4
6 8
0.8 H05 NDF 4
6 9
0.78 H05 NDF 4
6 11 0.39 H04 4
6 14 0.64 H02 4
6 14 0.42 H03 4
6 14 0.42 H04 4
6 15 0.2 C13 NDF 4
6 16 0.5 H02 4
6 16 0.69 H03 4
6 18 0.95 H02 SAI 4
6 19 0.79 H02 NDF 4
6 20 0.58 H02 SAI 4
6 20 0.75 H03 SAI 4
6 21 0.38 H02 NDF 4
6 21 0.87 H03 NDF 4
6 22 0.38 H02 4
6 23 0.5 H05 4
6 24 0.85 H04 NDF 4
6 25 0.75 H05 NDF 4
6 26 0.71 H02 4
6 28 0.82 H04 NDF 4
6 29 0.74 H02 NDF PLG 4
6 29 1.31 H04 SAI PLG 4
6 31 0.49 H03 NDF PLG 4
6 31 2.4 H04 SAI PLG 4
6 36 6.06 H02 SAI PLG 4
6 36 0.98 H04 SAI PLG 4
6 41 1.24 H02 SAI PLG 4
6 41 2.4 H03 SAI PLG 4
6 41 1.04 H04 SAI PLG 4
6 43 1
H03 SAI 4
6 50 1.05 H02 SAI PLG 4
6 71 0.87 H02 NDF 4
6 78 0.78 H02 NDF 4
6 78 0.81 H03 SAI 4
6 79 0.75 H02 NDF 4
6 80 0.26 H03 4
6 81 0.8 H02 SAI 4
6 81 0.74 H04 SAI
- This record was final approved on 2/10/2021 3:23:04 PM. (This statement was added by the PRIME system upon its validation)
WESTINGHOUSE NON-PROPRIETARY CLASS 3 A-29 SG-CDMP-21-1-NP February 2021 Revision 0 Table A-4 SG-4 U2R3 DSI Indications SG Row Col Volts Location Comments SAI/MAI NDF PLUG 4
6 82 0.92 H02 NDF PLG 4
6 82 0.53 H03 NDF PLG 4
6 84 0.75 H02 SAI PLG 4
6 84 0.35 H03 NDF PLG 4
6 84 0.69 H04 NDF PLG 4
6 86 0.4 H04 4
6 87 0.45 H04 4
6 89 0.65 H04 4
6 90 0.74 H02 4
6 90 0.59 H05 4
6 91 0.52 H04 4
6 92 0.6 H04 4
6 93 0.57 H04 4
6 94 1.27 H02 NDF 4
6 94 0.29 H03 NDF 4
6 94 0.88 H04 NDF 4
6 97 1.19 H02 NDF 4
6 97 0.44 H03 NDF 4
6 111 0.46 H03 4
7 33 0.89 H03 SAI 4
7 34 0.84 H02 NDF PLG 4
7 34 0.71 H03 SAI PLG 4
7 34 1.31 H04 SAI PLG 4
7 37 0.79 H03 SAI 4
7 40 0.46 H02 4
7 40 0.42 H03 4
7 46 0.5 H02 SAI PLG 4
7 46 0.54 H03 SAI PLG 4
7 46 1.02 H04 SAI PLG 4
7 100 0.7 H02 4
7 102 0.71 H03 4
7 106 0.61 H04 4
7 112 0.29 H02 4
7 112 0.53 H03 4
8 59 1.78 H02 SAI PLG 4
8 59 0.97 H03 SAI PLG 4
8 59 1.05 H04 SAI PLG 4
8 59 0.72 H05 NDF PLG 4
8 75 0.63 H05 4
8 83 0.39 C09 NDF
- This record was final approved on 2/10/2021 3:23:04 PM. (This statement was added by the PRIME system upon its validation)
WESTINGHOUSE NON-PROPRIETARY CLASS 3 A-30 SG-CDMP-21-1-NP February 2021 Revision 0 Table A-4 SG-4 U2R3 DSI Indications SG Row Col Volts Location Comments SAI/MAI NDF PLUG 4
8 95 0.68 H05 4
8 100 0.37 H03 4
9 2
0.54 H02 4
9 6
0.64 H04 4
9 11 0.48 H03 4
9 76 0.67 H05 4
9 86 0.72 H04 4
9 96 0.25 H05 4
9 100 0.58 H03 4
9 105 0.37 H02 4
9 107 1.15 H04 NDF 4
9 107 0.74 H06 SAI 4
9 111 0.48 H03 4
9 112 0.41 H05 4
9 113 0.49 H05 4
10 4
0.68 H03 4
10 5
0.2 H02 SAI 4
10 5
0.43 H03 SAI 4
10 5
0.8 H04 NDF 4
10 7
0.39 C09 NDF 4
10 7
0.71 H02 4
10 33 0.7 H02 NDF 4
10 33 0.85 H03 NDF 4
10 34 0.7 H02 4
10 34 0.49 H03 4
10 36 0.51 H02 NDF 4
10 36 0.96 H04 SAI 4
10 63 0.84 H02 SAI 4
10 77 0.88 H03 SAI 4
10 79 0.54 H05 4
10 88 0.4 H05 4
11 43 1.78 H02 SAI PLG 4
11 43 0.89 H03 SAI PLG 4
11 43 0.76 H04 NDF PLG 4
11 43 0.99 H05 NDF PLG 4
11 55 0.46 H05 4
11 89 0.81 H03 NDF 4
11 108 0.61 H03 4
11 108 0.49 H04 4
11 109 0.64 H02 SAI
- This record was final approved on 2/10/2021 3:23:04 PM. (This statement was added by the PRIME system upon its validation)
WESTINGHOUSE NON-PROPRIETARY CLASS 3 A-31 SG-CDMP-21-1-NP February 2021 Revision 0 Table A-4 SG-4 U2R3 DSI Indications SG Row Col Volts Location Comments SAI/MAI NDF PLUG 4
11 109 0.99 H03 SAI 4
11 112 1.22 H02 SAI PLG 4
11 113 0.99 H03 SAI 4
12 42 0.67 H02 4
12 43 0.47 H02 4
12 44 0.75 H03 SAI 4
12 61 1.14 H05 NDF 4
12 68 1.16 H03 SAI PLG 4
12 94 0.34 H05 4
13 5
0.36 H04 4
13 41 0.37 H04 4
13 59 0.25 H02 4
14 4
0.54 H04 4
14 40 0.39 C13 NDF 4
14 93 0.32 C13 NDF 4
15 19 0.28 H02 4
15 78 1.01 H02 NDF 4
15 87 0.88 H05 NDF 4
15 88 0.32 H05 4
15 90 0.67 H05 4
16 4
0.58 H03 4
16 5
0.45 H03 4
16 17 0.31 H02 4
16 23 0.5 H06 4
16 76 1.11 H02 SAI PLG 4
16 80 0.58 H02 4
16 84 0.53 H04 4
16 85 0.37 H05 4
16 90 0.29 H02 4
16 92 0.25 H05 4
16 94 0.2 H02 4
16 95 0.2 H02 4
16 111 0.52 H02 4
16 111 0.41 H03 4
17 6
1.05 H02 SAI PLG 4
17 40 0.39 H02 4
18 74 0.39 H02 4
18 81 0.26 C11 NDF 4
18 85 0.26 C06 NDF 4
18 94 0.5 H04
- This record was final approved on 2/10/2021 3:23:04 PM. (This statement was added by the PRIME system upon its validation)
WESTINGHOUSE NON-PROPRIETARY CLASS 3 A-32 SG-CDMP-21-1-NP February 2021 Revision 0 Table A-4 SG-4 U2R3 DSI Indications SG Row Col Volts Location Comments SAI/MAI NDF PLUG 4
18 96 0.44 H05 4
19 12 0.5 H03 4
19 31 0.38 H03 4
19 39 0.78 H03 SAI 4
19 39 0.75 H04 SAI 4
19 40 1.22 H02 SAI PLG 4
20 20 0.33 H04 4
20 75 0.55 H02 4
20 81 0.27 H02 4
21 12 0.55 H02 4
21 67 0.54 H02 SAI PLG 4
21 91 0.33 C02 NDF 4
21 95 0.82 H04 NDF 4
22 6
0.84 H04 NDF 4
22 11 0.4 H02 4
22 13 0.62 H02 4
22 13 0.72 H03 4
22 19 0.38 H03 4
23 12 0.76 H02 SAI 4
23 40 0.55 H02 4
23 92 0.21 H02 4
24 41 0.53 H02 4
24 88 0.59 H05 4
24 97 0.38 H04 4
24 104 0.48 H03 4
25 7
0.65 H02 4
25 33 0.57 H02 4
25 33 0.63 H04 4
25 33 0.3 H05 4
25 92 0.14 H05 4
25 98 0.31 H06 4
26 86 0.35 H02 4
26 89 0.46 H02 4
26 92 0.28 H06 4
26 96 0.42 H02 4
26 101 0.38 H03 4
26 101 0.43 H05 4
27 10 0.23 H03 4
27 12 0.28 C12 NDF 4
27 12 0.7 H06
- This record was final approved on 2/10/2021 3:23:04 PM. (This statement was added by the PRIME system upon its validation)
WESTINGHOUSE NON-PROPRIETARY CLASS 3 A-33 SG-CDMP-21-1-NP February 2021 Revision 0 Table A-4 SG-4 U2R3 DSI Indications SG Row Col Volts Location Comments SAI/MAI NDF PLUG 4
28 12 0.3 H02 4
28 31 0.63 H02 4
28 94 0.23 H02 4
28 96 0.22 H02 4
28 96 0.67 H04 4
30 17 0.34 H02 4
30 29 0.82 H02 SAI 4
30 104 0.39 H02 4
31 13 0.32 H03 4
31 16 0.78 H02 SAI 4
31 25 0.43 H02 4
31 29 0.4 H02 4
31 29 0.31 H03 4
31 102 0.59 H02 4
33 39 0.31 H07 4
34 37 0.36 H06 4
34 101 0.39 H03 4
34 102 0.49 H02 NDF 4
34 102 1.2 H03 NDF 4
35 14 0.8 H03 SAI 4
35 33 0.18 H03 4
35 101 0.64 H03 4
36 98 0.36 H02 4
38 25 0.32 H02 4
38 97 0.91 H03 NDF 4
38 98 1.37 H03 NDF 4
39 53 0.33 H02 4
41 27 0.49 H02 4
43 27 0.48 H06 4
43 90 0.56 H02 4
43 93 1.28 H02 NDF 4
43 93 1.06 H03 NDF 4
43 93 0.47 H04 NDF 4
44 76 0.77 H02 SAI 4
44 88 0.55 H05 4
44 90 0.62 H02 4
44 90 0.27 H04 4
44 90 0.63 H05 4
45 26 0.81 H04 NDF 4
45 90 0.39 H05
- This record was final approved on 2/10/2021 3:23:04 PM. (This statement was added by the PRIME system upon its validation)
WESTINGHOUSE NON-PROPRIETARY CLASS 3 A-34 SG-CDMP-21-1-NP February 2021 Revision 0 Table A-4 SG-4 U2R3 DSI Indications SG Row Col Volts Location Comments SAI/MAI NDF PLUG 4
47 29 0.61 H02 4
48 41 0.5 H02 4
48 41 0.37 H03 4
49 76 0.33 H06 4
49 83 1.29 H02 NDF 4
49 84 2.16 H02 SAI PLG 4
49 84 0.69 H03 NDF PLG
- This record was final approved on 2/10/2021 3:23:04 PM. (This statement was added by the PRIME system upon its validation)