ML20217D191
| ML20217D191 | |
| Person / Time | |
|---|---|
| Site: | Perry |
| Issue date: | 04/20/1998 |
| From: | Savio R NRC (Affiliation Not Assigned) |
| To: | Myers L CENTERIOR ENERGY |
| Shared Package | |
| ML20217D194 | List: |
| References | |
| RTR-REGGD-01.147, RTR-REGGD-1.147 TAC-MA0330, TAC-MA330, NUDOCS 9804240238 | |
| Download: ML20217D191 (4) | |
Text
!
April 20,1998 Mr. Lew W. Myers DISTRIBUTION:
Vice President - Nuclear PUBLIC Docket File Centerior Service Company PDill-3 r/f EAdensam P.O. Box 97, A200 OGC ACRS j
Perry, OH 44081 GBagchi EWoolridge, RES
]
GHill GGrant, R3
SUBJECT:
REQUEST TO USE CODE CASE N-524 AS AN ALTERNATIVE TO ASME CODE SECTION XI - PERRY NUCLEAR POWER PLANT, UNIT NO.1 (TAC l
NO. MA0330)
Dear Mr. Myers:
l Your letter of December 18,1997 (PY-CEl/NRR-2244L), requested approval for the implementation of the alternative criteria of ASME Section XI Code Case N-524 dated August 9, 1993, titled " Alternative Examination Requirements for Longitudinal Welds in Class 1 and 2 i
Piping,Section XI, Division 1," pursuant to 10 CFR 50.55a(a)(3) to be applied to the first 10-year inservice inspection interval for the Perry Nuclear Power Plant, Unit No.1.
The staff has reviewed your request and, pursuant to 10 CFR 50.55a(a)(3)(i), authorizes your use of Code Case N-524 for the Perry Nuclear Power Plant, Unit No.1 until such time as the Code Case is included in a future revision of Regulatory Guide 1.147. At that time, if you continue to implement the Code Case, you are to follow ali provisions in Code Case N-524 with limitations issued in Regulatory Guide 1.147, if any. The staff's evaluation and conclusions are contained in the enclosed Safety Evaluation.
If you have quest!ons, please contact Douglas Pickett at (301) 415-1364.
Sincerely, ORIG. SIGNED BY:
Richard P. Savio, Acting Director Project Directorate lil-3 Division of Reactor Projects -Ill/IV Office of Nuclear Reactor Regulation Docket No. 50-440 jf \\
Enclosure:
Safety Evaluation Y, oI cc w/ encl:
see next page l
l DOCUMENT NAME: G:\\ PERRY \\CCASE_N.524 To receive a copy of this document. Indicate in the box:
"C" = Copy without enclosures *E" = Copy with enclosures "N" = No copy 0FFICE PM:PDIII-3 E.
LA:PDIII-3 8
OG$#f$$
BC:ECGB (A)D:PDIII-3 NAME DPickett~'
EBarnhillyfP hh GBagchi*
RSavio //pr i
l DATE 04/9 /98 04/f/98
'04//[/98' 04/01/98 04/do/98 0FFICIAL RECORD COPY
- See GBagchi to GMarcus memorandum of April 1,1998
. n
,)
5 {p 'D 7 *;"
- W " T " li jh f ul D {'..~ m.e u ku d WCA u 9804240238 980420 PDR ADOCK 05000440 P
p nau g*
4 UNITED STATES g
j NUCLEAR REGULATORY COMMISSION
't WASHINGTON, D.C. 30866 4001
%...../
April 20, 1998 Mr. Lew W. Myers Vice President - Nuclear Centerior Service Company P.O. Box 97, A200 Perry, OH 44081
SUBJECT:
REQUEST TO USE CODE CASE N-524 AS AN ALTERNATIVE TO ASME CODE SECTION XI - PERRY NUCLEAR POWER PLANT, UNIT NO.1 (TAC NO. MA0330)
Dear Mr. Myers:
Your letter of December 18,1997 (PY-CEl/NRR-2244L), requested approval for the implementation of the attemative criteria of ASME Section XI Code Case N-524 dated August 9, 1993, titled " Alternative Examination Requirements for Longitudinal Welds in Class 1 and 2 Piping,Section XI, Division 1," pursuant to 10 CFR 50.55a(a)(3) to be applied to the first 10-year inservice inspection interval for the Perry Nuclear Power Plant, Unit No.1.
The staff has reviewed your request and, pursuant to 10 CFR 50.55a(a)(3)(i), authorizes your use of Code Case N-524 for the Perry Nuclear Power Plant, Unit No.1 until such time as the Code Case is included in a future revision of Regulatory Guide 1.147. At that time, if you continue to implement the Code Case, you are to follow all provisions in Code Case N-524 with limitations issued in Regulatory Guide 1.147, if any. The staff's evaluation and conclusions are contained in the enclosed Safety Evaluation.
If you have questions, please contact Douglas Pickett at (301) 415-1364.
Sincerely, Richard P. Savio, Acting Director Project Directorate lll-3 Division of Reactor Projects -lil/IV Office of Nuclear Reactor Regulation Docket No. 50-440
Enclosure:
Safety Evaluation cc w/ encl:
see next page
1 L. Myers Perry Nuclear Power Plant, Units 1 and 2 Centerior Service Company cc:
l Jay E. Silberg, Esq.
James R. Williams Shaw, Pittman, Potts & Trowbridge Chief of Staff 2300 N Street, NW.
Ohio Emergency Management Agency Washington, DC 20037 2855 West Dublin Granville Road Columbus, OH 43235-2206 Mary E. O'Reilly Centerior Energy Corporation Mayor, Village of Perry 300 Madison Avenue 4203 Harper Street Toledo, OH 43652 Perry, OH 44081 Resident inspector's Office Roy P. Lessy, Jr.
U.S. Nuclear Regulatory Commission Akin, Gump, Strauss, Hauer P.O. Box 331 and Feld, L.L.P.
Perry, OH 44081-0331 1333 New Hampshire Ave., NW.
Suite 400 Regional Administrator, Region 111 Washington, DC 20036 U.S. Nuclear Regulatory Commission 801 Warrenville Road Radiological Health Program Lisle, IL 60532-4531 Ohio Department of Health P.O. Box 118 Lake County Prosecutor Columbus, OH 43266-0118 Lake County Administration Bldg.
105 Main Street Ohio Environmental Protection Painesville, OH 44077 Agency DERR-Compliance Unit Sue Hiatt ATTN: Mr. Zack A. Clayton OCRE Interim Representative P.O. Box 1049 8275 Munson Columbus, OH 43266-0149 Mentor, OH 44060 Chairman Terry J. Lodge, Esq.
Perry Township Board of Trustees 618 N. Michigan Street, Suite 105 3750 Center Road, Box 65 Toledo, OH 43624 Perry, OH 44081 Ashtabula County Prosecutor State of Ohio 25 West Jefferson Street Public Utilities Commission Jefferson, OH 44047 East Broad Street Columbus, OH 43266-0573 Henry L. Hegrat Regulatory Affairs Manager William R. Kanda, Jr., Plant Manager Cleveland Electric illuminating Co.
Cleveland Electric illuminating Co.
Perry Nuclear Power Plant Perry Nuclear Power Plant P.O. Box 97, A210 P.O. Box 97, SB306 Perry, OH 44081 Perry, OH 44081
a
. cc: (cor;tinued)
Donna Owens, Director Ohio Department of Commerce Division of Industrial Compliance Bureau of Operations & Maintenance 6606 Tussing Road P.O. Box 4009 Reynoldsburg, OH 43068-9009 Mayor, Village of North Perry North Perry Village Hall 4778 Lockwood Road North Perry Village, OH 44081 Attorney General Department of Attorney General 30 East Broad Street Columbus, OH 43216
.