05000413/LER-2020-002, Re Unacceptable Indication Identified During Reactor Pressure Vessel Head Nozzle Penetration Inspection

From kanterella
(Redirected from ML20212L578)
Jump to navigation Jump to search
Re Unacceptable Indication Identified During Reactor Pressure Vessel Head Nozzle Penetration Inspection
ML20212L578
Person / Time
Site: Catawba Duke Energy icon.png
Issue date: 07/30/2020
From: Simril T
Duke Energy Corp
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
RA-20-0246 LER 2020-002-00
Download: ML20212L578 (5)


LER-2020-002, Re Unacceptable Indication Identified During Reactor Pressure Vessel Head Nozzle Penetration Inspection
Event date:
Report date:
Reporting criterion: 10 CFR 50.73(a)(1), Submit an LER, Invalid Actuation

10 CFR 50.73(a)(2)(ii)(A), Seriously Degraded

10 CFR 50.73(a)(2)(i)(A), Completion of TS Shutdown

10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications

10 CFR 50.73(a)(2)(i)

10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition

10 CFR 50.73(a)(2)(iii)

10 CFR 50.73(a)(2)(iv)(A), System Actuation

10 CFR 50.73(a)(2)(v)(A), Loss of Safety Function - Shutdown the Reactor

10 CFR 50.73(a)(2)(v)(B), Loss of Safety Function - Remove Residual Heat

10 CFR 50.73(a)(2)(v), Loss of Safety Function

10 CFR 50.73(a)(2)(vii), Common Cause Inoperability

10 CFR 50.73(a)(2)(viii)(A)

10 CFR 50.73(a)(2)(viii)(B)

10 CFR 50.73(a)(2)(ix)(A)

10 CFR 50.73(a)(2)(x)
4132020002R00 - NRC Website

text

"( ~ DUKE ENERGY.

RA-20-0246 July 30, 2020 U.S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, D.C. 20555

Subject:

Duke Energy Carolinas, LLC Catawba Nuclear Station, Unit 1 Docket No.59-413 Licensee Evert Report (LER) 413/2020-002-00 Tom Simril Vice President Catawba Nuclear Station Duke Energy CN01VP 14800 Concord Road York, SC 29745 o: 803.701.3340 f; 803.701.3221 10 CFR 50.73 Pursuant to 10 CFR 50.73(a)(1) and (d), attached is LER 413/2020-002-00, entitled" Unacceptable Indication Identified During Reactor Pressure Vessel Head Nozzle Penetration Inspection." This report is being submitted in accordance with 10 CFR 50.73(a)(2)(ii)(A).

This LER was previously submitted on July 13, 2020. The cover letter incorrectly stated the LER as revision 1. The correct revision of the LER is revision 0, as indicated in the Attachment to this letter.

There are no regulatory commitments contained in this letter or its attachment.

This event is considered to be of no significance with respect to the health and safety of the public.

If questions arise regarding this LER, please contact Sherry E. Andrews of Regulatory Affairs at (803) 701-3424.

Sincerely, Tom Simril Vice President, Catawba Nuclear Station Attachment

United States Nuclear Regulatory Commission Page 2 July 30, 2020 xc (with attachment):

L. Dudes Regional Administrator U.S. Nuclear Regulatory Commission - Region II Marquis One Tower 245 Peachtree Center Ave., NE Suite 1200 Atlanta, GA 30303 K. Cotton NRC Project Manager (CNS)

U.S. Nuclear Regulatory Commission 11555 Rockville Pike Mailstop O-8G9A Rockville, MD 20852 J. Austin (without enclosure)

NRC Senior Resident Inspector

NRC FORM 366 (04-2020)

U.S. NUCLEAR REGULATORY COMMISSION LICENSEE EVENT REPORT (LER)

(See Page 2 for required number of digits/characters for each block)

(See NUREG-1022, R.3 for instruction and guidance for completing this form http://www.nrc.gov/reading-rm/doc-collections/nuregs/staff/sr1022/r3/)

APPROVED BY OMB: NO. 3150-0104 EXPIRES: 04/30/2020

NRC FORM 366 (04-2020) 05000

3. Page 1

OF

4. Title
5. Event Date Month Day Year
6. LER Number Year Sequential Number Rev No.
7. Report Date Month Day Year
8. Other Facilities Involved Facility Name Docket Number 05000 Facility Name Docket Number 05000
9. Operating Mode
10. Power Level
11. This Report is Submitted Pursuant to the Requirements of 10 CFR §: (Check all that apply) 20.2201(b) 20.2201(d) 20.2203(a)(1) 20.2203(a)(2)(i) 20.2203(a)(2)(ii) 20.2203(a)(2)(iii) 20.2203(a)(2)(iv) 20.2203(a)(2)(v) 20.2203(a)(2)(vi) 20.2203(a)(3)(i) 20.2203(a)(3)(ii) 20.2203(a)(4) 50.36(c)(1)(i)(A) 50.36(c)(1)(ii)(A) 50.36(c)(2) 50.46(a)(3)(ii) 50.73(a)(2)(i)(A) 50.73(a)(2)(i)(B) 50.73(a)(2)(i)(C) 50.73(a)(2)(ii)(A) 50.73(a)(2)(ii)(B) 50.73(a)(2)(iii) 50.73(a)(2)(iv)(A) 50.73(a)(2)(v)(A) 50.73(a)(2)(v)(B) 50.73(a)(2)(v)(C) 50.73(a)(2)(v)(D) 50.73(a)(2)(vii) 50.73(a)(2)(viii)(A) 50.73(a)(2)(viii)(B) 50.73(a)(2)(ix)(A) 50.73(a)(2)(x) 73.71(a)(4) 73.71(a)(5) 73.77(a)(1) 73.77(a)(2)(i) 73.77(a)(2)(ii)

Other (Specify in Abstract below or in Page of 05000-

3. LER NUMBER YEAR SEQUENTIAL NUMBER REV NO.

CORRECTIVE ACTIONS

The indication was addressed by the application of light surface conditioning. A PT was performed after the surface conditioning evolution. No indications were identified by final PT. The amount of material removed from the j-groove weld was evaluated for structural integrity acceptance in accordance with ASME code requirements. The evaluation of the as-left condition after indication removal determined the j-groove weld to be acceptable for continued service.

SAFETY ANALYSIS

Ultrasonic testing determined the linear indication was not through-wall. There was not a breach in the fission product barrier, and the structural integrity of the reactor vessel was not compromised. Therefore, there was no impact to the health and safety of the public.

ADDITIONAL INFORMATION

There have been no previous Licensee Event Reports at Catawba Nuclear Station on this issue.

3 3

Catawba Nuclear Station, Unit 1 413 2020 002 00

,,>A AEG<,l

/~\\

~

~

'0/...,_,,

+o' I

I I

I* I I D