Forwards Rev 0 to ABWR Design Control Document (Dcd). DCD Comprised of Introduction,Certified Design Matl & Approved Safety Analysis Matl.Responses to NRC Comments Requested by Also Encl
ML20149G708
Person / Time
Site: 05200001
Issue date: 10/28/1994
From: Quirk J
GENERAL ELECTRIC CO.
To: Crutchfield D
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM), Office of Nuclear Reactor Regulation
Shared Package
ML20149G710 List:
References
MFN-134-94, NUDOCS 9411020070
Download: ML20149G708 (71)


Text

____

GENuclearEneryy Joseph F Oud Gews!Electre Company ABWR Licensey Manager 175 Cwtw Avenue, MC 782, San ae, CA 951251014 RojectManager ABWRCerticaton 408 92M219(phone) 400 92542b7(tacsunile)

October 28,1994 MFN No.134-94 Docket No.52-001 Docket Control Desk U.S. Nuclear Regulatory Commission

(

Washingtco, D.C. 20555-0001 Attention:

Mr. Dennis M. Crutchfield Associate Director, Advance Reactors and License Renewal

}

SUIljECT: SUI 1MITTAL OF FINAL AllWR DESIGN CONTROL DOCUMENT i

References:

(1) DM Crutchfield toJF Quirk, dated August 3,1994.

(2) DM Crutchfield toJF Quirk, Certification of the Design Control Document (DCD) for the Advanced Boiling Water Reactor (AllWR), dated September 27,1994.

(3) JF Quirk to RW Borchardt, Submittal of AllWR Design Control Decument (DCD), dated September 7,1994.

(4) JF Quirk to DM Crutchfield, Design Control Document (DCD),

Unidentined Changes, October 5,1994.

Enclosed is one (1) copy of the Design Control Document (DCD) for the Docket Control Desk and one (1) copy for the Public Document Room. Further, in accordance wth directien of NRR project staff, General Electric Nuclear Energy (GE-NE) is providing thirteen (13) copies of the DCD to the NRR recipients listed on. This is being done to accelerate the distribution process and ensure timely staff receipt of the DCD.

The DCD is comprised of an Introduction, the Certified Design Material (i.e.,

Tier 1), and the Approved Safety Analysis Material (i.e., Tier 2). The DCD is prosided consistent with NRC's Guidance IAtter (Reference 1) as clarified in subse<1uent discussions with NRR. The DCD provides, in a single document, design-related information to be incorporated by reference in the design certification rule for the AllWR standard design.

M DJ i c/,,-

{(v

  • '8

~

4g g 9411020070 941028 h

4 *. h PDR ADOCK 05200001 I

A PDR r

O As requested by Reference 2, the enclosed DCD incorporates staff comments on the presious DCD transmittal (Reference 3). Specific GE-NE responses to the staff comments are prosided in Attachment 2. Also as requested by Reference 2, GE-NE certifies that the current DCD is accurate and complete and that all differences l

between the DCD and the SSAR/CDM and the reasons for them are identified (Attachment 3). Finally, the root cause of why unidentified changes occurred in the presious DCD transmittal and the corrective measures taken is the subject of Reference 4.

Meetings between the staff and GE-NE to discuss GE-NE submittals of proposed I

sections and a proposed DCD Introduction have proved a beneficial means fi>r co s tructively resohing issues raised by staff comments and reaching agreement on appropriate implementing language for the relevant DCD provisions. GE-NE has incorporated the agreed upon language in the DCD package submitted herewith. We note, in particular, the agreed upon fermat fbr identifying deleted SSAR sections and specifying their non-DCD status; the designation of Tier 2* material and the j

specification of a change mechanism for that material which provides fbr staff approval prior to change implementation; deletion of SSAR proprietary and safeguards infbrmation; deletion of detailed PRA-related data; specifying the status of ITAAC following a s52.103(g) finding; and the expiration of specified Tier 2*

information once a referencing plant achieves 100% power.

Discussion continues on the last remaining DCD issue, regarding the applicability of the s50.59-like process to Chapter 19. The GE-NE proposal (br resohing that issue is contained in Section 3.8 of the DCD Introduction submitted herewith. In summag, the section prosides that 1) a safety evaluation shall be performed if a change would either adversely affect a function identified as an important feature in Section 19.8 or would climinate or preclude a function identified in Chapter 19 as sening to prevent or mitigate a severe accident; and 2) prior NRC approval in the form of a COL or COL amendment shall be sought if the safety evaluation determines that the change would significantly increase the probability or consequences of a severe accident evaluated in Chapter 19. In the near future, we intend to submit a paper which explains the basis for our proposal and to discuss this matter with the staff at a meeting on November 2,1994.

Also, we understand that the Notice of Proposed Rulemaking (NPR) will identify National Technical Information Senice ar the source of contact for the i

public to obtain copics of the Dua. We agree that this is the appropriate course.

We would be pleased to discuss with you any questions you may have with regard to this submittal.

2

Sincerely,

Jpseph F. Quirk Attachments cc:

with enclosure w/o enclosure w/o enclosure AJ Beard (GE)

SM Franks (DOE)

FJ Miraglia (NRC)

ND Fletcher (DOE)

RW Borchardt (NRC)

NT Patel (GE)

SP Frantz (Newman, TH Iloyce (NRC)

WH Rasin (NEI)

Bouknight & Edgar)

JN Fox (GE)

RL Simard (NEI)

MA Rowden (Fried, SA Hucik (GE)

RJ Bell (NEI)

Fran k...)

FA Ross (DOE) 3 2

ATTACHMENT I DIRECT SHIPMENT OF DCD TO NRR RECIPIENTS OUANITY RECIPIENT ORGANIZATION 3

RICHARD W. BORCHARDT NRR/ADAR/PDST 1

GOUTAM BAGCHI NRR/ADT/DE/ECGB 1

CARL BERLINGER NRR/ADT/DE/EELB 1

CONRAD E.McCRACKEN NRR/ADT/DSSA/SPLB '

1 ROBERTC. JONES NRR/ADT/DSSA/SRXB 1

RICHARD J. BARRETT NRR/ADT/DSSA/SCSB 1

EDWARD J. BUTCHER NRR/ADT/DSSA/SPSB 1

MATTHEW CHIRAMAL NRR/ADT/DRCH/HICB 1

MARYLEE M. SLOSSON NRR/ADT/DRCH/HHFB 1

R. LEE SPESSARD NRR/ADT/ DOTS 1

JANICE E. MOORE

'OGC m

ATTACHMENT 2 ABWR DCD SUBMITTAL OF SEPTEMBER 7,1994 GERESPONSES TO NRC COMMENTS I.

Comments on DCD Tier 2* and Other Items from PDST 1.

Per discussion in the GE/NRC meeting at SanJose, CA on September 27 and 28, 1994, Section 3.5, and Tables 1 and 8 of DCD/ Introduction have been modified to include the " sunset" provision for " Tier 2*" commitments designated in DCD/ Introduction Tables 2,3,4,8 (initial fuel design only),9,10 and 11. These commitments are identified for expiration of" Tier 2*" change restriction following "First Full Power "

2.

During the GE/NRC meeting at SanJose, CA on September 27 and 28,1994, several areas of DCD/ Introduction were also discussed. The NRC staff provided their comments on DCD/ Introduction in a letter dated October 4,1994 and discussed them with GE in a meeting on October 6,1994 at Rockville, MD. The staff faxed an acceptable language of Section 3.4 of DCD/ Introduction on October 20,1994 and documented the meeting summag of the October 6th meeting in a memo dated October 21,1994. GE and its consultants (Messrs.

Rowden and Frantz) have been interacting with NRR and OGC staff. Based on the above, the DCD/ Introduction has been prepared subject to resolution of role of PRA/SA information in the DCD and in 10CFR50.59 process. The cover letter transmitting this attachment addresses this issue and other residual issues.

3.

During the GE/NRC meeting at SanJose, CA on September 27 and 28,1994, several areas of DCD/ Tier 2 were also discussed. Specifically, the staff commented on Chapter 19 of PRA/SA analyses. GE and staff agreed to markups of Appendices 19I,19M and 19R for' inclusion in the October submittal.

The staff discussed moving Appendix 19P to the ABWR Technical Support Document and confirmed it in the memo of October 21,1994.

Subsequently, GE (N. Patel) and the staff (Messrs. Thomas and Chiramal) interacted and agreed to remove the fault trees and event trees from Chapter 19 and 15 for consistency with the markups of Appendices 191,19M and 19R.

Chapter 15, including Appendix 15D, were revised to repine specific probabilities by qualitative phrases.

II.

Comments on DCD Tier 2* and Other Items from Reactor Systems 1.

Tier 2* Comment (from George Thomas):

Y....

ABWR DCD SUBMITTAL OF SEPTEMBER 7,1994 GERESPONSES TO NRC COMMENTS Per discussion in the GE/NRC meeting, the front page of Appendix 4B in DCD/ Tier 2 is revised (1) by deleting the previous words "[ Proprietary information not part of DCD (Refer to [SSAR Appendix 4B])"," (2) by including Section "4B.1 Introduction A set of fuel... USNRC review. [Thefuellicensing acceptance cn'te ia arepresented in Reference 4B-1. Any change to these criteria requires priorNRC review and approval]*," with ellipsis standing for words from Section 4B.1 of SSAR, and (3) by including Section "4B.2 References", with first entry

  • [4B-1 SSAR Sections 4B.2 through 4B.16.]*". The footnote, "* See Section 4.2" is kept as is.

2.

Miscellaneous Comments (from Robert C. Jones):

(1) Subsection 15.2.4.3.1, SSAR page 15.2-15, the third paragraph is reinstated in the DCD.

(2) Subsection 15.2.4.3.2.2, DCD page 15.2-15, the second paragraph is deleted from the DCD.

(3; Subsection 15.2.6.2.1, SSAR page 15.2-22, the last paragraph is reinstated in the DCD.

(4) Section 15E.5, DCD page 15E-5, Item 11, the SSAR value in metric units for 300 psig are reinstated in the DCD.

(5) Section 15E.7, DCD page 15E-9, Item 11, the last paragraph of SSAR is reinstated in the DCD.

(6) (a) Table 15E-3, DCD page 15E-12, the SSAR values in metric units for setpoints for relief valve and low closure pressure of MSIV are reinstated in the DCD.

(b) Tables 15E-4 through 15E-22, the SSAR values in metric units for maximum vessel bottom pressure are reinstated in the DCD.

(7) Subsection 19L.5.3, DCD page 191,8, Item 3, the last sentence was deleted properly as resolved by Alan Beard (GE) earlier.

(8) Subsection 19L.5.4, DCD page 19L-9, Item 1, the DCD is correct per the comment in regard to an attempt to withdraw a "second" rod.

(9) Subsection 19L.7.3, DCD page 191,20, the DCD is correct per the comment in regard to two diesel generators during Mode 4.

(10) Subsection 19L8.4, DCD page 191,24, deleted "(~6.0E-13 per year)" per the comment.

2

ABWR DCD SUBMITTAL OF SEPTEMBER 7,1994 GERESPONSES TO NRC COMMENTS III.

Comments on DCD from Instrumentation & Controls 1.

Self-Test System Design Testing Features and Commitments:

The two typing errors regarding words, "7.1.2.1.6" and " submitted," are corrected in DCD/ Tier 2 Subsection 7.1.1.2. DCD/ Introduction Table 1 is modified to include " Subsection 7.1.1.2"in the table and "11" in place of"10"in Note (1).

2.

Instrument Setpoint Methodology; Regulatory Guide 1.105:

DCD/ Introduction Table 9 is modified to correctly laclude "7.2.2.2.1(6)" in the table and " italicized" in Note (2).

3.

SSLC Hardware and Software Qualification:

Per discussion in the GE/NRC meeting, no change is required to Table 11 of DCD/ Introduction.

It should be noted that per conversation earlier and during the meedng between Nil Patel (GE) and Matt Chiramal (NRC), Section 7C.4, " Common Mode Failure Analysis," will be removed from Tier 2* delineation because the subsection deals with chronological events of the analyses communications.

4.

EMS Performance Specifications and Architecture:

In DCD Tier 2 Table 1.9-21, please note that, for MII,HDBK-251, Superscript

"(3)"is used instead of"*" to refer to Note (3) at the end of the table for reference to Tier 2 Section 7A.1(1).

IV.

Comments on DCD Tier 2* Items for Structural Codes and Standards 1.

Table 1 of DCD/ Introduction is revised accordingly to include "and Division 1, Subsection NE," for description of Table 2.

2.

Table 2 of DCD/ Introduction is revised accordingly to include " Subsection NE,"

in the second commitment.

3.

Tier 2 Subsection 3.8.4.4.1 is revised accordingly.

4.

Tier 2 Subsection 3.8.4.5.1.2 is revised accordingly with revised title for the subsection as " Structural and Materials Criteria." The suggested Subsection 3.8.4.5.1.1 was not modified because it deals with general (non-structural) criteria.

3 b..

ABWR DCD SUBMITTAL OF SEPTEMBER 7,1994 GERESPONSES TO NRC COMMENTS V.

Comments on DCD hv EELB 1.

The comment is incorporated. The errors from middle of Page 9.5-36 are corrected.

VI.

Comments on DCD Tier 2* Items Pertainine to Eouinment Dynamic Oualification 1.

Table 6 of DCD/ Introduction is revised to replace "3K.6" with correct "3K.7" for Tests and Analyses commitments.

2.

Note (12) of DCD Tier 2 Table 3.9-2 is revised accordingly by deleting "and" between "and 3" and " pumps."

VII.

Comments on DCD Tier 2* Items Pertainine to Pipine Desien Acceptance Criteria 1.

The comment is incorporated. The first added delineation begins from the middle of Page 3.7-21 of DCD/ Tier 2 and ends as follows. "The integration time step is considered acceptable when. one-tenth of the smallest period of interest." The second added delineation is, "When the. <ime-history method of analysis is used, the time-history data is broadened plus and minus 15% of At in order to account for modeling uncertainties."

2.

The comment is incorporated. The sixth item of Table 7 of DCD/ Introduction is revised to include "/ Interaction" at the end of the commitment description.

3.

The comment is incorporated. The wordings in the two figures are italicized. No change is required to Table 7 of DCD/ Introduction.

4.

The comment is incorporated. No change is required to Table 7 of DCD/ Introduction.

5.

The comment is incorporated. No change is required to Table 7 of DCD/ Introduction.

VIII. Comments on DCD by HHFB 1.

None.

4

6 ABWR DCD SUBMITTAL OF SEPTEMBER 7,1994 l

GERESPONSES TO NRC COMMENTS 1

IX.

Comments on DCD hv OTSB (9/14/94 and 9/15/94 Letters)

\\

l.

"Rev. 0" is moved to footer and "ABWR SSAR" is replaced (formally) with DCD/ Tier 2.

j l

2.

OTSB found no differences between DCD and SSAR Tech Specs. (9/15/94 i

Letter).

X.

Comments on DCD by PRPB (9/16/94 and 9/20/94 Letters) l.

DCD table of figures was corrected to include parenthetical units "(Gy/h)." This will be maintained in the DCD.

2.

Figure 12.3-74 was redrafted so that it is clearer and easier to read. The updated figure will be retained.

3.

Values for h, and h, were not included on Page 12A-2 of DCD/ Tier 2. These values r

(419J/g and 2676J/g) will be included in DCD.

i 4.

Subsection 6.4.2.5.1 is revised to show that Halogens available for release from containment is 25% (instead of 2.7%).

XI.

Comments on DCD by RPEB (9/12/94 and 9/15/94 Letters) 1.

No comments on Sections 17.1 and 17.2.

)

2.

Table 17.3-1 will be restored as requested by putting the example Fussel-Vesely Importance values back in the table.

4 XII.

Comments on DCD by SCSB 1.

Per discussion in the GE/NRC meeting, (1) it is considered necessary that DCD j

does not contain the PRA numbers and (2) it is considered acceptable that a reference can be made to a deleted portion which references SSAR.

2.

GE has reviewed the submittal for the PRA numbers that have been left in inadvertently. These numbers have been deleted and proper wording substituted.

3.

Per discussion in the GE/NRC meeting, it is considered acceptable that DCD does not contain sections referenced in the FSER.

5

a ABWR DCD SUBMITFAL OF SEPTEMBER 7,1994 GE RESPONSES TO NRC COMMENTS 4.

Per discussion in the GE/NRC meeting, it is considered appropriate that 10CFR 50.59 change process be limited to considerations of the important features identified in Section 19.8.

XIII. Comments on DCD by SPLB (Attachment to Letter dated 9/15/9.41 1.

Page 3.4-15: Changed "ABWER" to "ABWR."

2.

Page 3.5-8:

Correctly relocated the left hand side of equations.

3.

Page 5.2-44: Changed "RCU' to "FiCW."

4.

Page 6.2-61: Replaced "various" with " containment isolation" in the fifth paragraph.

5.

Page 6.2-63: Inserted "of GDC 54" after " requirement" and "that" in the first paragraph.

6.

Page 6.2-63: Inserted " power-operated" in front of " isolation valve" in the fifth paragraph.

7.

Page 6.2-63: Replaced "nonpowered" with " manual" in the sixth paragraph.

8.

Page 6.4-2:

The space in front of"SRP Section 6.4" in the second paragraph exists, but appears not to exist because of the type style used by the word processing software.

9.

Page 9.1-12: Two words "must be" at the end of the fourth line are deleted.

10. Page 9.1-15: Replaced "stroage" with " storage" in the last line of the middle paragraph.

I1. Page 9.1-65: Replaced "FULE" with " FUEL" in the left side of Figure 9.1-7.

12. Page 9.1-68: Replaced "34.9 m" with "3.49 m" in the top middle of the figure.
13. Page 9.2-12: The second "well" is correctly used as an adjective as is the third "well." No change is made.
14. Page 9.2-52: Replaced "54.01" with "127.24" in the fourth column of Table 9.2-4a.
15. Page 9.3-9:

In Subsection 9.3.3.2, correctly referenced Subsection 9.3.3.1 instead of deleting the reference per the comment. Further,in the second 6

fa ABWR DCD SUBMITFAL OF SEPTEMBER 7,1994 GERESPONSES TO NRC COMMENTS 1

I sentence, changed "in" to "is" in front of" discussed in this -

1 subsection."

16. Page 9.3-9:

Changed "is" to "are" in Subsection 9.3.3.2.1.

17. Page 9.3-22: Maintained the top paragraph which was lost in the SSAR due to -

printing rollover in Amendment 34. In Subsection 9.3.7.3, deleted first "of" from the first line.

18. Page 9.4-55: Figures 9.4-2a and 9.4-2b are listed on Page 9.4-53, ahead of Figure 9.4-2c, Page 9.4-54. No change is required to Page 9.4-55.
19. Pages21-543 Figure 9.4-4: Since the term " essential" is utilized in many places in through the SSAR, DCD and FSER, it is not replaced with " safety related" as 21-545:

suggested by the comment.

20. Page 21-546: The missing page (Figure 9.4-8, Drywell Cooling System P&lD) is included.
21. Pages 9.5-45 It appears that these pages were removed from the reviewer's through -58:

package, since other packages contained the pages.

22. Page 9.5-86: The correct current SSAR Figure 9.5-4 is utilized to replace the incorrect figure.
23. Page 9A.2-5: Metric units are used for the calorific value in Item (12).
25. Page 9A.4-481: Replaced 377 C with 37.8 C in Item (5)(c) at top.
25. Page 10.1-4: Deleted minus sign in front of 188.5 in Table 10.1-1,
26. Page 10.2-2: Replaced "sec" with "s" ;n Subsection 10.2.1.3.3(2).
27. Page 10.2-3: The paragraph before Subsection 10.2.2.2 is made consistent with the SSAR paragraph.
28. Page 10.2-18: The typographical error and misprint of abscissa title is corrected to be consistent with SSAR.
29. Page 10.3-2: (i) Deleted " nominal" after 700A from the second line of Subsection 10.3.2.1. (ii) Replaced 87.89 kg/cm'g with 8.62 MPaG in the first line of second paragraph of Subsection 10.3.2.1.

l

30. Page 10.4-40: The first page of Figure 10.4-4 is made consistent with SSAR.

7 l

6 ABWR DCD SUBhilTTAL OF SEPTEhiBER 7,1994 GERESPONSES TO NRC COMMENTS

31. Page 11.2-1 The end of the second sentence from the bottom is revised to read,"

... the HSD sample tank or the LCW sample tank."

32. Page 11.2-5 the second line of Subsection 11.2.3.1 is revised to read,"... effluent from the LCW sample tank or the hot shower drain sample tank as indicated on the..."
33. Page 11.4-3: The second hne ofitem (3) is revised by changing "25 hiGy/hr" to "25 Gy/hr "
34. Page 11.4-7 Added missing right parentheses in column headings of Table 11.4-1.
35. Page 11.5-3: The middle paragraph-sentence of Subsection 11.5.1.2 is revised at two places: "10CFR20.106" is replaced with "10CFR20.1302" and

" Amendments 1 and 2" is replaced with " Attachments 1 and 2."

36. Page 11.5-20 Changed "higy/h" to "mGy/h" in the last line of" Channel Range" column of Table 11.5-1.
37. Pages 11.5-20 See revised Tables 11.5-1 through 11.5-3 of the DCD transmitted through with this attachment. The display specifications of Subsections 11.5-25:

11.5.2.1.1 and 11.5.2.1.2 are compared with the sensitivity and range given in Tables 11.5-1 and 11.5-2. Also, the expected activity is compared with the detection range in Tables 11.5-2 and 11.5-3. The changes resulting from these comparisons and incorporated into the revised tables are listed on Pages Il-1 through 11-3 of Attachment 3 8

ATTACHMENT 3 DIFFERENCES BETWEEN DCD AND SSAR/CDM LEGEND Cateeory Descriotion 1

NRC Comment 2

NRC DCD Guidance a.

Tier 2*

b.

Proprietary Information c.

Probabilistic/EventTree/FaultTree d.

Safeguards Information e.

Internal Consistency (Tierl/CDM and Tier 2/SSAR) 3 GE Initiated Change for Clarification or Elimination of Disconnects 4

DCD Improvements over the SSAR or CDM of Significant Value.

Improvements of Lesser Value and not Specifically Recorded are:

Minor Improvements in Format Correction of Spelling Enhanced Grammar Inclusion of Scanned / Redrafted Figures Corrections to Table of Contents Replacement of " Deleted" with "Not Used" Commensurate with a New Document

Differences Between ABWR DCD and CDM Sections 2 through 5 Item DCD DCD No.

Pages Section Difference Cat.

Reason

}

1 v/vi Table of Contents Added footnote "** section number in 4

Lost in a rollover parenthess-section, under which the subject is covered."

2 2.12.1-1 2.12.1 Inserted "at least" before "a UAT or a RAT" 3

Clarification in second line of next to last paragraph.

[

3 2.14.6-5/6 Table 2.14-6 Changed "7.3.4 kg/cm2" to "0.72 MPa" under 4

Incomplete units conversion item 6.

4 2.12.14-1 2.12.14 and Deleted "is a voltage regulating device and" 3

Clarification and Figure 2.12.14 in front of "The alternate power supply" at 2.12.14-3 the end of the fourth paragraph and replaced

" VOLTAGE REGULATING DEVICE" with

" ALTERNATE POWER SUPPLY"in figure.

5 2.15.5-7 2.15.5 Changed "45 C" to "50 C".

3 Max room temperature lower than maximum outside air. See Chapter 9 changes.

6 2.15.5-23 Figure 2.15.5 Reversed HWH inlet to outlet and HNCW 3

Clarification outlet to inlet.

7 5.0-2 Table 5.0 Changed "26.6 C" to "26.7 C" under 1%

3 Rounding error exceedance values.

a 8

5.0-2 Table 5.0 Changed "717.85 kPa" to "718.20 kPa" 3

Conversion error under minimum static bearing capacity.

CDM-1

Differences Between ABWR DCD and SSAR Chapter 1 Item DCD DCD No.

Pages Section Difference Cat.

Reason 1

1.1-1 1.1.1 Replaced " Advanced Boiling Water Standard 2e NRC DCD Guidance Safety Analysis Report" with " Tier 2" in first paragraph.

2 1.1-1 1.1.1 Replaced "SSAR" with " Tier 2" in second 2e NRC DCD Guidance paragraph.

3 1.2-24 1.2.2.10.1.3 Removed last sentence.

4 Last two sentences the same.

4 1.6-1 1.6 Replaced section title and introductory 4

Clarification sentence 5

1.6-2 Table 1.6-1 Changed "SSAR" to " Tier 2" in right-hand 2e NRC DCD Guidance thru 1.6-6 column.

6 1.7-1 1.7.1 Replaced "..the ABWR SSAR" with " Tier 2" 2e NRC DCD Guidance in second line.

7 1.7-23 Table 1.7-2 Under item 2D changed explanation of 4

Clarification function from " Output exists if and only if all specified inputs exist" to " Output exists if specified number of inputs exist."

8 1.7-24 Table 1.7-2 in truth table for item 3C changed "1" to "0" 4

Correction in right-hand bottom corner.

9 1.8-12, Table 1.8-19 Italicized SRP 3.5.3,3.8.1 and 4.2 2a NRC DCD Guidance 1.8-13 Appendices, and added 2 footnotes to page 1.8-24.

10 1.8-27 Table 1.8-20 Corrected title of Reg. Guide 1.43.

4 Correction 11 1.8-27 Table 1.8-20 Italicized Reg. Guide 1.47 and referenced 2a NRC DCD Guidance footnote 4.

1-1

_..- -. - - -. ~.. -. -. - -..

I I

Diffaranc:s Between ABWR DCD and SSAR

-l Chapter 1 (Continued)

Item DCD DCD No.

Pages Section Difference Cat.

Reason 12 1.8-29 Table 1.8-20 Italicized Reg. Guide 1.75 and referenced 2a NRC DCD Guidance i

footnote 4.

13 1.8-30 Table 1.8-20 Italicized Reg. Guides 1.92 and 1.100 and 2a NRC DCD Guidance referenced footnotes 1 and 2, respectively.

14 1.8-31 Table 1.8-20 Italicized Reg. Guide 1.105 and referenced 2a NRC DCD Guidance footnote 3.

15 1.8-34 Table 1.8-20 Italicized Reg. Guides 1.152 and 1.153 and :

2a NRC DCD Guidance i

referenced footnote 4.

l 16 1.8-34.1 Table 1.8-20 Added notes (1) thru (4) 2a NRC DCD Guidance 17 1.8-35 Table 1.8-21 Changed "1983" to "1989" under ACI 318 3

UBC references ACI 318-entry.-

1989. Changed forinternal i

consistency.

18 1.8-35 Table 1.8-21 Italicized the following codes and standards:

2a NRC DCD Guidance. Also f

thru ACI349 IEEE 845 added MIL-HDBK-217 and l

1.8-87 AISC N690 lEEE 1012 IEC 801-2 for consistency ANS 7-4.3.2' IEEE 1023 with text.

ANS 57.5 IEEE 1033 i

ANS 58.2 IEEE 1042 i

ANSI /HFS-100 lEEE 1228 (Draft) j ANSI N101.4 DOD 5000.2 ANSI /NOA-2a DOD AD/A223168 ASTM C776 DOE AR602-1

.i ASTM C934 DOE DI-HFAC-80740 IEEE C37.90.2 DOE ESD-TR-86-278 IEEE C62.41 DOE HDBK-761 A IEEE C62.45 DOE HDBK-763 IEEE C63.12 DOE-STD-2167A 1

1-2 j

~

m

_~m,i__..

... 4 -

l Differences Bstwesn ABWR DCD and SSAR Chapter 1 (Continued) l it m DCD DCD e

j No.

Pages Section Difference Cat.

Reason 18 IEEE 279 DOD TOP 1-2-610 IEEE 323 MIL-H-46855B (Cont)

IEEE 338 MIL-HDBK-217 IEEE 344 MIL-HDBK-251 lEEE 384 MIL-HDBK-759A i

IEEE 603 MIL-STD-461C

[

IEEE 730 MIL-STD-462 l

IEEE 802.2 MIL-STD-1472D IEEE 802.5 MIL-STD-1478 IEEE 828 IEC 801-2 IEEE 829 IEC 880 IEEE 830 IEC 964 and added the corresponding eight notes to i

page 1.8-87.

19 1.8-36 Table 1.8-21 Revised title of ANSI A58.1.

4Property "ANSI code" (as page type) with input value "ANSI A58.1.</br></br>4" contains invalid characters or is incomplete and therefore can cause unexpected results during a query or annotation process. Cleanup 20 1.8-46 Table 1.8-21 Added ASCE 71988 under"others".

4 Missing reference i

21 1.9-1 1.9 Replaced "SSAR" with " Tier 2" 3 places.

2e NRC DCD Guidance 22 1 A-11 1 A.2.9 Italicized " Plant-specific SRV models - with 2c NRC DCD Guidance NUREG-0737 requirements"'

23 1 AA-2 1 AA.2(3).

Changed "3.87E-6 c/kgh" to "1.5E-4 Gy/h" 4

Correct units and "1.29E-4 c/kgh" to "5.0E-3 Gy/h".

l 24 1 AA-3 1 AA-3.1 in first paragraph replaced "SSAR" with 2e NRC DCD Guidance 4

" Tier 2".

1 25 1 AA-6 1 AA.4.3 In second paragraph replaced "0.983" with 2c NRC DCD Guidance

. i i

" estimated to be very high" i

I i

1-3 m.

mm m

m m

___,e,-._.

..-.ew, m

...~._....,....s--_,.

Differ:nc s B tween ABWR DCD and SSAR Chapter 2 I Item DCD DCD No.

Pages Section Difference Cat.

Reason 1

2.0-2 Table 2.0-1 Changed "26.6 C" to "26.7 C" under 1%

4 Rounding error Exceedance Value for Ambient Design Temperature.

2 2.0-2 Table 2.0-1 Changed '717.85 kPa" to "718.20 kPa" 4

Conversion error under Minimum Static Bearing Capacity.

2-1

+

Differences Between ABWR DCD and SSAR Chapter 3 Item DCD DCD No.

Pages Section Difference Cat.

Reason 1

3.2-8 3.2.5.3(3)

Italicized text, added footnote.

2a NRC DCD Guidance 2

3.2-8, 3.2.5.3(4)

Italicized (a) and (b), added footnote on page 2a NRC DCD Guidance 3.2-9 3.2-9.

3 3.2-9 3.2.5.3 Italicized last paragraph, using footnote of 2a NRC DCD Guidance item 2.

4 3.2-63 Table 3.2-3 Six places, italicized text, added footnote.

2a NRC DCD Guidance 5

3.4-15 3.4.2 Second paragraph, first line: replaced 1

Incorrect acronym; NRC "ABWER" with "ABWR".

comment 6

3.5-8 3.5.1.1.2.2(4)

Equation (3.5-3): Removed small dashes 4

Consistency with Figure from top of "f".

3.5-1 definition 7

3.6-12 3.6.2.1.4.1 Italicized text, added footnote.

2a NRC DCD Guidance 8

3.6-12 3.6.2.1.4.2 Italicized text, added footnote on page 2a NRC DCD Guidance 3.6-14.

9 3.6-14 3.6.2.1.4.3 Italicized text, added footnote on page 2a NRC DCD Guidance 3.6-15.

10 3.6-15 3.6.2.1.4.4 Italicized text, using item 9 footnote.

2a NRC DCD Guidance 11 3.6-15 3.6.2.1.4.5 Italicized text, using item 9 footnote.

2a NRC DCD Guidance 12 3.6-16 3.6.2.1.5.2 Italicized text, added footnote.

2a NRC DCD Guidance 13 3.6-17 3.6.2.1.5.3.1 Italicized text, added footnote.

2a NRC DCD Guidance 14 3.6-17 3.6.2.1.5.3.2 Italicized text, using item 13 footnote.

2a NRC DCD Guidance 15 3.6-22 3.6.2.3.1 Italicized text, added footnote on page 2a NRC DCD Guidance thru 3.6-25.

3.6-25 3-1

Differences Between ABWR DCD and SSAR Chapter 3 (Continued) ltem DCD DCD No.

Pages Section Difference Cat.

Reason 16 3.6-25 3.6.2.3.2.1 Italicized text, added footnote.

2a NRC DCD Guidance 17 3.6-26 3.6.2.3.2.2 Italicized text, using item 16 footnote.

2a NRC DCD Guidance 18 3.6-29 3.6.3 Changed "this SSAR" to " Tier 2" in second 2e NRC DCD Guidance paragraph.

19 3.7-8, 3.7.2.1.4 Italicized text, added footnote on page 3.7-9.

2a NRC DCD Guidance 3.7-9 20 3.7-21 3.7.3.1 Italicized text three places, added footnote.

2a NRC DCD Guidance 21 3.7-22 3.7.3.2 Italicized text three places, added footnote.

2a NRC DCD Guidance 22 3.7-23 3.7.3.3.1.2 Italicized text, added footnote.

2a NRC DCD Guidance 23 3.7-23 3.7.3.3.1.3(1)

Italicized text, added footnote.

2a NRC DCD Guidance 24 3.7-24 3.7.3.3.1.4 Changed "the SSAR" to " Tier 2" in first 2e NRC CDC Guidance paragraph 25 3.7-25 3.7.3.3.1.4(2)

Italicized text, added footnote.

2a NRC DCD Guidance 26 3 7-25 3.7.3.3.1.6 Italicized text, using Item 25 footnote.

2a NRC DCD Guidance 27 3.7-25 3.7.3.3.1.7 Italicized text, using item 25 footnote.

2a NRC DCD Guidance 28 3.7-25, 3.7.3.3.1.8 Italicized text, added footnote on page 2a NRC DCD Guidance 3.7-26 3.7-26.

29 3.7-27 3.7.3.3.4 Italicized text three places, added footnote.

2a NRC DCD Guidance 30 3.7-28, 3.7.3.6 Italicized text, added footnote on page 2a NRC DCD Guidance 3.7-29 3.7-29.

31 3.7-29 3.7.3.7.1 Italicized text, added footnote on page 2a NRC DCD Guidance thru 3.7-31.

3.7-31 3-2

. a

-m

Differences Between ABWR DCD and SSAR Chapter 3 (Continued)

Item DCD DCD No.

Pages Section Difference Cat.

Reason 32 3.7-31 3.7.3.7.2 Italicized text, added footnote on page 2a NRC DCD Guidance thru 3.7-33.

3.7-33 33 3.7-35, 3.7.3.8.1.6 Italicized text, added footnote on page 2a NRC DCD Guidance 3.7-36 3.7-36.

34 3.7-36, 3.7.3.8.1.7 Italicized text, added footnote on page 2a NRC DCD Guidance 3.7-37 3.7-37.

35 3.7-37 3.7.3.8.1.8 Italicized text, using footnote of item 34.

2a NRC DCD Guidance 36 3.7-38, 3.7.3.8.1.9 Italicized text two places, added footnote on 2a NRC DCD Guidance 3.7-39 page 3.7-39.

37 3.7-39 3.7.3.8.1.10 Italicized text, using footnote of item 36.

2a NRC DCD Guidance 38 3.7-40, 3.7.3.13 Italicized text two places, added footnote on 2a NRC DCD Guidance 3.7-41 page 3.7-41.

39 3.8-2 3.8.1.1.1 Added an italicized paragraph with footnote.

2a NRC DCD Guidance 40 3.8-3 3.8.1.2.2 Italicized text, added footnote.

2a NRC DCD Guidance 41 3.8-20 3.8.2.2.3 Italicized first paragraph, added footnote.

2a NRC DCD Guidance 42 3.8-22 3.8.2.4.1.4 Italicized second paragraph, added footnote.

2a NRC DCD Guidance 43 3.8-27 3.8.3.2 Added an italicized paragraph with footnote.

2a NRC DCD Guidance 44 3.8-28 3.8.3.2 Added an italicized paragraph with footnote.

2a NRC DCD Guidance 45 3.8-30 3.8.3.5.1 Italicized text, added footnote.

2a NRC DCD Guidance 46 3.8-30 3.8.3.5.2 Italicized text, using item 45 footnote.

2a NRC DCD Guidance 47

'3.8-35 3.8.4.2.1(1)

Italicized text, added footnote.

2a NRC DCD Guidance 3-3

Differences Between ABWR DCD and SSAR Chapter 3 (Continued)

Item DCD DCD No.

Pages Section Difference Cat.

Reason 48 3.8-36 3.8.4.2.1(2)

Italicizeo text, added footnote, and changed 2a NRC DCD Guidance

" Table 3.8-10" to " Table 3.8-9".

49 3.8-37 3.8.4.2.1(9)

Removed "88" from ANSI /ASCI 7 4

Date is applied by Table 1.8-21 50 3.8-38 3.8.4.2.2 Italicized first sentence, added footnote.

2a NRC DCD Guidance 51 3.8-38 3.8.4.2.3 Changed "AISC" to " ANSI /AISC-N690" and 2a NRC DCD Guidance italicized first sentence, using item 47 footnote.

52 3.8-44 3.8.4.4.1 Italicized first sentence, added footnote.

2a NRC DCD Guldance 53 3.8-46 3.8.4.5.1.2 Changed title from " Materials Criteria" to 2a NRC DCD Guidance

" Structural and Materials Criteria" and added italicized sentence.

54 3.8-46 3.8.4.5.2 Italicized first sentence, added footnote.

2a NRC DCD Guidance 55 3.8-46 3.8.4.5.3 Italicized first sentence, using item 54 2a NRC DCD Guidance footnote.

56 3.8-47 3.8.5.2 Italicized text, added footnote.

2a NRC DCD Guidance 57 3.8-54, Table 3.8-4 Italicized References 13,14 and 15, added 2a NRC DCD Guidance 3.8-55 footnotes on page 3.8-55.

58 3.8-54 Table 3.8-54 Changed " Table 3.9-10" to " Table 3.9-9" in 4

Correction Reference 15 59 3.8-55 Table 3.8-4 Removed Note 1.

1 NRC comment 60 3.8-60 Table 3.8-9 Italicized text, added footnote.

2a NRC DCD Guidance 61 3.8-61, Table 3.8-10 Italicized text, added footnote on page 2a NRC DCD Guidance 3.8-62 3.8-62.

3-4 T

w-

~r--

i l

Differences Between ABWR DCD and SSAR I

Chapter 3 (Continued) l Item DCD DCD No.

Pages Section Difference Cat.

Reason 62 3.9-1 3.9.1.2 Italicized last paragraph, added footnote.

2a NRC DCD Guidance 63 3.9-7 3.9.1.7 Created a new Subsection 3.9.1.7 with an 2a NRC DCD Guidance italicized paragraph and footnote.

64 3.9-14 3.9.2.2.1 Italicized text three places, added footnote.

2a NRC DCD Guidance 65 3.9-28 3.9.3.1 Italicized text three places, added footnote.

2a NRC DCD Guidance 66 3.9-29 3.9.3.1 Italicized text two places, added footnote.

2a NRC DCD Guidance 67 3.9-32 3.9.3.1.1.7 Italicized text, added footnote.

2a NRC DCD Guidance 68 3.9-36 3.9.3.1.20 Italicized text, added footnote.

2a NRC DCD Guidance 69 3.9-36 3.9.3.1.21 Italicized text, using item 68 footnote.

2a NRC DCD Guidance 70 3.9-36 3.9.3.1.22 Italicized text, using item 68 footnote.

2a NRC DCD Guidance 71 3.9-37 3.9.3.2.1.1 Italicized a last portion of first paragraph, 2a NRC DCD Guidance added footnote.

72 3.9-41 3.9.3.2.3.1.4 Italicized a sentence, added footnote.

2a NRC DCD Guidance 73 3.9-42 3.9.3.2.3.1.4 Italicized text two places, added footnote.

2a NRC DCD Guidance 74 3.9-45 3.9.3.2.5.1.2 Italicized a sentence, added footnote.

2a NRC DCD Guidance 75 3.9-50 3.9.3.4 Italicized last three sentences, added 2a NRC DCD Guidance footnote.

76 3.9-50 3.9.3.4.1 Italicized text three places, using item 75 2a NRC DCD Guidance footnote.

77 3.9-51 3.9.3.4.1 Italicized text two places, added footnote.

2a NRC DCD Guidance 78 3.9-51, 3.9.3.4.1 Italicized text three places, added footnote.

2a NRC DCD Guidance 3.9-52 3-5

Diff rencas Betwacn ABWR DCD and SSAR Chapter 3 (Continued) i item DCD DCD No.

Pages Section Differerice Cat.

Reason 79 3.9-53 3.9.3.4.1 Italicized text one place, added footnote.

2a NRC DCD Guidance 80 3.9-53, 3.9.3.4.1 Italicized text two places, added footnote.

2a NRC DCD Guidance 3.9-54 81 3.9-55 3.9.3.4.1(5)

Italicized a sentence in first paragraph, 2a NRC DCD Guidance added footnote.

82 3.9-56 3.9.3.4.1(6)

Italicized text two places, added footnote.

2a NRC DCD Guidance 83 3.9-77 3.9.6.2.2 Added an italicized paragraph at top with

.2a NRC DCD Guidance footnote.

84 3.9-77 3.9.6.2.2(1)

Italicized text, added footnote.

2a.

NRC DCD Guidance 85 3.9-77, 3.9.6.2.2(2)

Italicized text,'added footnote on page 2a NRC DCD Guidance 3.9-78 3.9-78 86 3.9-84 3.9.8 Italicized Reference 3.9-6, added footnote 2a NRC DCD Guidance i

87 3.9-84 3.9.8 Italicized References 3.9-7,3.9-9,3.9-10, and 2a NRC DCD Guidance 3.9-11 and added footnote 88 3.9-86 Table 3.9-1 Italicized Event 12, added footnote 2a NRC DCD Guidance -

89 3.9-87 Table 3.9-2 Italicized Event 3, added footnote 2a NRC DCD Guidance 90 3.9-88 Table 3.9-2 Italicized Notes 7 and 9, added footnote 2a NRC DCD Guidance i

91 3.9-88 Table 3.9-2 Italicized Note 12, added footnote 2a NRC DCD Guidance l

92 3.9-139 Table 3.9-8 Deleted "SSAR" under notes (a) and (d) 2e NRC DCD Guidance 93 3.10-1 3.10 Added an italicized paragraph with footnote.

2a NRC DCD Guidance 94 3.10-2 3.10.1.1 Italicized text three places, added footnote.

2a NRC DCD Guidance 95 3.10-3 3.10.1.3 Italicized last sentence, added footnote.

2a NRC DCD Guidance 3-6

__,,.m,.

Differences Between ABWR DCD and SSAR Chapter 3 (Continued)

Item DCD DCD No.

Pages Section Difference Cat.

Reason 96 3.10-3 3.10.2.1 Italicized last sentence using item 89 2a NRC DCD Guidance footnote.

97 3.13-11 3.13.4.5 Changed "SSAR" to " Tier 2" 2e NRC DCD Guidance 3.13.4.6 3.13.4.7 98 3.13-14 3.13.5.2 Replaced "are less than 1% of" with "is a 2b NRC DCD Guidance very small percentage of the" in the last paragraph 99 3.11-5 3.11.7 Italicized reference 3.11-2 and added 2a NRC DCD Guidance footnote 100 3A-85 Figure 3A-17 Provided correct figure for elevation 4

incorrect figure in SSAR

-10.95 m 101 3A-295 and Figures 3A-227 Reversed these figures 4

Incorrect in SSAR 3A-296 and 3A-228 102 3B-24 thru Tables 3B-2 thru Changed "provided under separate cover" 2b NRC DCD Guidance 3B 39 3B-9 to "not part of DCD (Refer to SSAR Appendix 3B" 3B-41 and Figure 38-2 and 3B-42 3B-3 3B-47 thru Figure 3B-8 thru 38-49 3B-10 38-53 thru Figures 3B-14 thru 38-59 38-20 3B-61 thru Figures 38-22 thru 3B-64 38-25 3-7

Differences Betwe:n ABWR DCD and SSAR Chapter 3 (Continued)

Item DCD DCD No.

Pages Section Difference Cat.

Reason 102 38-66 and Figures 3B-27 (cont) 3B-68 and 3B-29 3B-70 thru Figures 38-31 3B-73/74 thru 38-34 103 3B-27 3B.4.4.1 Removed "SSAR" in third line of first 2e NRC DCD Guidance paragraph.

104 3E-43 Figure 3E-6 Removed duplicate title in body of figure.

4 Cleanup 105 3G-14 Figure SG-7 Replaced Figure 3G-7 [AP LOAD (MS 4

Correction NOZZLE BREAK) CASE AP2, NODE: 81, HORIZONTAL] with Figure 3G-7 [AP LOAD (MS NOZZLE BREAK) CASE APA2, NODE:

33 HORIZONTAL) 106 3H.1-3 3H.1.4.1.1 Italicized codes (1), (3) and (5) and added 2a NRC DCD Guidance footnotes 107 3H.1-3 thru 3H.1.4.2 Revised parameters to be consistent with 4

Cleanup 3H.1-5 Table 2.0-1 and deleted date from ASCE 7.

108 3H.1 -7 3H.1.4.3.1.3 Revised snow load to agree with 4

Cleanup Table 2.0-1.

109 3H.2-2 thru 3H.2.4 Revised parameters to be consistent with 4

Cleanup 3H.2-6 Table 2.0-1 and deleted date from ASCE 7.

110 3H.2-2 and 3H.2.4.1, and Italicized ACl349 and ANSI /AISC-N690 2a NRC DCD Guidance 3H.3-2 3H.3.4.1 111 3H.3-2 thru 3H.3.4 Revised parameters to be consistent with 4

Cleanup 3H.3-5 Table 2.0-1 and deleted date from ASCE 7.

3-8

~

E Differences Between ABWR DCD and SSAR I

Chapter 3 (Continued) item DCD DCD No.

Pages Section Difference Cat.

Reason-112 3H.3-29 Figure 3H.3-1 Changed "0.15 ksf" with "7.18 kPa" and 4

Units conversion "4.48 ksf" with "215 kPa" in vertical center of table.

113 31-7 Table 31-4 Deleted footnote 2 and changed "40" to "50" 3

Must cool with outside air for diesel generator room.

as high as 46.1 C 114 3K-1 thru 3K Added entire appendix 2a NRC DCD Guidance 3K-6 115 3L-1 and Figures 3L-8 Removed duplicate title in body of figures.

4 Cleanup 3L-2 and 3L-9 116 3M-6 3M.7(1)

Removed."in the SSAR" from third line of 2e NRC DCD Guidance first paragraph.

117 3M-7 3M.8 Replaced "SSAR" with " Tier 2", 2 places 2e NRC DCD Guidance 118 3MA-19 3MA.5.2 Char'ged "SSAR" to " Tier 2" 2e NRC DCD Guidance

[

3-9 f

Differences Between ABWR DCD and SSAR Chapter 4 Item DCD DCD No.

Pages Section Difference Cat.

Reason 1

4.2-1 4.2 Added italicized paragraph with footnote.

2a NRC DCD Guidance 2

4.2-1 4.2 Added italicized sentences with footnote.

2a NRC comment 3

4.2-3 thru 4.2.2.1 and Italicized text, added footnote on page 4.2-5.

2a NRC DCD Guidance 4.2-5 4.2.2.2 4

4.2-5 thru 4.2.3.1.1 Italicized text, added footnote on page 4.2-6.

2a NRC DCD Guidance 4.2-6 5

A.2-6 4.2.3.1.2 Italicized text using item 4 footnote.

2a NRC DCD Guidance 6

4.2-7 4.2.5 Italicized references, added footnote.

2a NRC DCD Guidance 7

4.2-8 Figure 4.2-1 Italicized title, added footnote.

2a NRC DCD Guidance 8

4.2-9/10 Figure 4.2-2 Italicized title, added footnote.

2a NRC DCD Guidance 9

4.3-2 4.3.2.1 Italicized a sentence, added footnote.

2a NRC DCD Guidance 10 4.3-8 Figure 4.3-1 Italicized title, added footnote.

2a NRC DCD Guidance 11 4A-1 4A.1, 4 A.2, Italicized text, added footnote.

2a NRC DCD Guidance 4A.3 12 48-1 4B.1 Italicized sentences, added footnote.

2a NRC DCD Guidance 13 4B-1 4B.2 Replaced proprietary SSAR Sections 4B.2 2b NRC DCD Guidance through 48-16 with Reference AB-1, italicized the reference using item 12 footnote.

14 4C-1 4C.1 Italicized sentences, added footnote.

2a NRC DCD Guidance 15 4C-1, 4C.2, Italicized, added footnote on page 4C-2.

2a NRC DCD Guidance 4C-2 4C.3 4-1

...m

1 r

Differences Between ABWR DCD anu SSAR Chapter 4 (Continued)

Item DCD DCD No.

Pages Section Difference Cat.

Reason 16 4D-1 4D Removed proprietary information, referenced 2b NRC DCD Guidance.

SSAR.

I T

i 4-2

.s

Diffar:mces Betw0cn ABWR DCD and SSAR Chapter 5 hem DCD DCD No.

Pages Section Difference Cat.

Reason 1

5.2-30 5.2.4.3.2.1 Added " Appendix SA demonstrates 4

Ties appendix to text.

compliance with Regulatory Guide 1.150." at bottom of section.

i 2

5.2-44 5.2.5.2.2(11)

Replaced "RCU" with "RCW" in middle of 1

incorrect acronym; NRC paragraph.

comment.

3 5.2-51 thru Table 5.2-1 Added code case N-476 and italicized code 2c NRC DCD Guidance 5.2-53 cases N-71-15 through N-430 and N-476.

4 5.3-13 5.3.3.1.1.1 Added " located between the two seal rings.

4 Should be part of SSAR.-

A monitor line is attached to the tap to

" Lost"in a rollover.

provide an indication of leakage from the inner seal-ring seal." to the bottom of the page.

5 5.4-16 5.4.5.4 Replaced " sections" with "s" in second 4

" sections" should be sentence of second paragraph.

" seconds" and abbreviated as "s".

6 5.4-29 5.4.7.1 Added " pressure" in front of " design" in 4-Missing word.

fourth to last line of subsection.

i 7

5.4-66 Table 5.4-4 Changed "32.6 C" to "37.8 C".

3 See reason foritem 2 of Chapter 9.

i 5-1

+..,-w.<e.-.-..w.-

m..-m..~

o--.

1--,,,,w...-w.-,-

4-w< ew-.v.wn w

.,w,-

,,.-.i

  • r

-c m.--w.,.

..rm..

.+.2-=

.-,,...-.-.---.-..m,_,.w-,_~._

. _, _m

Differences Between ABWR DCD and SSAR Chapter 6 Item DCD DCD No.

Pages Section Difference Cat.

Reason 1

6.2-14 6.2.1.1.3.5 Removed subsection 6.2.1.1.3.5.

3 Not required with UHS of 35 C.

2 6.2-26 6.2.1.1.5.5 Added " sense a gap between the disk and 4

Lost in SSAR amendment l

the seating surface, if the gap is less than rollover.

9 mm," following the third line of the third paragraph.

3 6.2-61 0.2.4.2 Added " containment isolation" before 1

NRC comment

" signals" in the seventh paragraph of Section 6.2.4.2.

4 6.2-62 6.2.4.2.6 Added "of GDC 54" in front of "that no active 1

NRC comment failure..." in the first paragraph of the section.

5 6.2-63 6.2.4.2.6 Added " power operated" in front of " isolation 1

NRC comment valve arrangements..." in fifth paragraph of the section.

6 6.2-63 6.2.4.2.6 Replaced "nonpowered" with " manual" in 1

NRC comment front of " isolation valves is maintained..." in the last paragraph of the section.

7 6.2-126 Table 6.2-7 Changed "SSAR" to " Tier 2".

2e NRC DCD Guidance thru 6.2-167 8

6.3-44 Table 6.3-15 In third line of second column changed "PFL" 4

Incorrect acronym to "LPFL".

9 6.3-32 and Tables 6.3-6 and Changed "[ Proprietary information provided.

2b NRC DCD Guidance i

6.3-50 Figures 6.3-10 under separate cover)" to "[ Proprietary thru 6.3-29 information not part of DCD (Refer to SSAR 6.3-87/88 Section 6.3)]".

6-1

Differences Between ABWR DCD and SSAR Chapter 6 (Continued)

Item DCD DCD No.

Pages Section Difference Cat.

Reason 10 6.4-7 6.4.2.5.1 Changed "2.7%" to "25%" in the third column 1

NRC comment of the table under " halogens".

11 6.4-9 6.4.4.2 Removed "... with portable air analyzers 4

SentenceNpeated due to indicate the need to do so. However, the rollove;.

operator is allowed..." from the top of the page.

12 6A-12 6A Added " activated carbon is greater than two 4

Originally in SSAR, lost in a inches deep, each representative" to top of

rollover, the page.

l 4

6-2

l Differences Betwe n ABWH DCD and SSAR Chapter 7 Item DCD DCD No.

Pages Section Difference Cat.

Reason 1

7.1-7 thru 7.1.2.1.6 Italicized text, added footnote on 2a NRC DCD Guidance 7.1-11 page 7.1-11.

2 7.1-31 7.1.2.10.9 Added Italicized paragraph with footnote.

2a NRC DCD Guidance 3

7.2-32 7.2.2.2.1(6)

Italicized " Regulatory Guide 1.105" and 2a NRC DCD Guidance added footnote.

4 7.3-72 7.3.2.1.2(3)(f)

Italicized RG1.105 and Reference 7.3-2 and 2c NRC DCD Guidance added footnote.

5 7.3-96 7.3.4 Italicized Reference 7.3-2 and added 2a NRC DCD Guidance footnote.

6 7.4-24 7.4.2.3.2(3)(f),

Italicized RG1.105 and added footnote.

2c NRC DCD Guidance 7.6-23 7.6.2.1.2(3)(f),

7.6-30 7.6.2.6.2(3)(f) 7 7.5-24 thru Tables 7.5-4, Changed " Safety Analysis" to " Tier 2" in third 2e NRC DCD Guidance 7.5-27 7.5-5 and 7.5-6 column.

8 7.5-28 Table 7.5-8 Replaced "S" with "T" in right hand column 2e NRC DCD Guidance and "S=SSAR" with "T= Tier 2" in footnote.

9 7.6-3 7.6.1.1.1(4)

Changed "nv" to " neutron /cm2" four places.

4 incomplete units conversion 10 7.6-27 7.6.2.3 Replaced "SSAR" with Tier 2 2e NRC DCD Guidance 11 7.6-30 7.6.2.6.2(3)

Italicized RG 1.105.

2a NRC DCD Guidance 12 7.6-47 Figure 7.6-9 Removed duplicate title in body of figure.

4 Cleanup 13 7.7-77 7.7.1.11 Replaced "of the SSAR" with " Tier 2" in first 2a NRC DCD Guidance line.

7-1

Differences Between ABWR DCD and SSAR Chapter 7 Item DCD DCD No.

Pages Section Difference Cat.

Reason 14 7A-1 7A.1 Added two italicized paragraphs with 2a NRC DCD Guidance footnote 15 7A-2 7A.2 Italicized all of Section 7A.2 2a NRC DCD Guidance thru 7A-12 16 7A-7 7A.2 Changed "the SSAR" to " Tier 2" in 2e NRC DCD Guidance Response (11) 17 7A-12 7A.3 Italicized all of Section 7A.3 and added 2a NRC DCD Guidance thru 7A-15 footnote 18 7A-16 7A.5 thru 7A.7 Italicized Sections 7A.5 through 7A.7 and 2a NRC DCD Guidance thru 7A-20 added footnote 19 7B-1 78.1 Changed "lEEE (draft H)" to "lEEE 1228 4

Reference Update (draft)" under item (1)(a)(iv).

20 78-1 7B.1 thru 78.3 Italicized Sections 78.1 through 78.3 and 2a NRC DCD Guidance thru 7B-7/8 added footnotes 21 7C-2 7C.2 and 70.3 Italicized Section 7C.2 and added footnote 2a NRC DCD Guidance thru 7C-5 22 70-5 7C.4 in first paragraph changed "less than 10E-6" 2c NRC DCD Guidance to " extremely low."

23 7C-7 7C.4 Replaced "2200 F" with "1204 C" under 4

Incomplete units change JUNE 1992 24 7C-11 7C.5 Italicized Section 7C.5 and added footnote.

2a NRC DCD Guidance thru 7C-13 7-2

I Differences Between ABWR DCD and SSAR Chapter 8 Item DCD DCD No, Pages Section Difference Cat.

Reason 1

8.2-15 Table 8.2-1 "SSAR" changed to " Tier 2" on first line.

2e NRC DCD Guidance 1

8-1

Differences Between ABWR DCD and SSAR Chapter 9 Item DCD DCD No.

Pages Section Difference Cat.

Reason 1

9.1-6 9.1.2.1.3 Changed "1361 kg" to "13.35 kN" under 4

incomp!ete unit conversion.

Item 6, 2

9.2-6 9.2.5.1(1)

Changed "37.8 C" to "35 C average" at end 3

During the course of the of item (1).

staff review, GE changed from 95 F (35 C) to 100 F (37.8 C) and the FDA ver-sion of the SSAR ended at the 100 F value. Page 2-11 of the FSER shows a 95 F value for the UHS (Emer-gency Cooling Water inlet).

As part of the FOAKE program, the systems cooled by the UHS were evaluated and it was determined that the federally mandated phase out of several commonly used refrigerants would require lowering the UHS temperature to 95 F (35 C).

FOAKE also found that plate type heat exchangers would be much more suitable. Finally, it is prudent to allow the use of both screw-type and centrifugal-type chillers.

9-1

,u-

,+r-ne-,.

,~

e

. m

,.e-m

,,,,-m v

-,- < ~,.,


c-

Differences Between ABWR DCD and SSAR Chapter 9 (Continued)

Item DCD DCD No.

Pages Section Difference Cat.

Reason 3

9.2-20 9.2.11.1.1(1)

Changed "37.8 " to "(i.e.,35 F average)" in 3

See reason for item 2 second line of second paragraph.

above.

4 9.2-21 9.2.11.2 Inserted the following paragraph:

3 See reason for item 2 above.

"The Control and Service Building general arrangement drawings, Figures 1.2-14 through 17 (and companion Fire Protection drawings, Figures 9A.4-11 through 13, and Radiation Protection drawings, Figures 12.3-42,43,48 and 64) show the location of the RCW pumps and heat exchangers. (Note:

The heat exchangers are depicted as shell-and-tube type; however, the alternate plate-type can be accommodated in the same area of the Control Building in a horizontal arrangement at elevation -8200mm, the same elevation as the pumps)."

5 9.2-22 9.2.11.2 Removed "due to tube plugging" in 3

See reason for item 2 paragraph beginning with "The above above.

analysis shown..."

6 9.2-25 9.2.11.3.2 Removed "the tubing side" from paragraph 3

See reason for item 2 beginning with " System components and above.

piping materials..."

7 9.2-27 9.2.11.4 Replaced " tube plugging" with " leakage" in 3

See reason for item 2 next to last sentence in first paragraph.

above.

8 9.2-27 9.2.11.4 Replaced last word " fouling" in second 3

See reason for item 2 paragraph with " refurbishing" above.

9-2

Differences Between ABWR DCD and SSAR Chapter 9 (Continued)

Item DCD DCD No.

Pages Section Difference Cat.

Reason 9

9.2-28 9.2.11.5 Replaced "a tube leak" with " leakage" in the 3

See reason for item 2 next to the last paragraph.

above.

10 9.2-31 9.2.13.2 Deleted " centrifugal" in front of compressor 3

See reason for item 2 in the third sentence of the second above.

paragraph.

11 9.2-34 9.2.13.5 Changed last sentence of third paragraph to 4

Consistency with P&lDs read "two-way valve based on refrigerant compressor discharge pressure".

12 9.2-52 Table 9.2-4a Changed "54.01" to "127.24" in the fourth 1

NRC comment column of the total load entry.

13 9.2-60 Table 9.2-8 Removed " type-centrifugal hermetic" 3

See reason for item 2 above.

14 9.3-5 9.3.2.3.4 Changed " Reactor" to " Turbine" in front of 4

Correction

" Building Sample Station" 15 9.3-9 9.3.3.2 Removed "(Subsection 9.3.2.1)" from the 1

NRC comment first line.

16 9.3-9 9.3.3.2.1 Changed "is" to "are".

1 NRC comment 17 9.3-13 9.3.5.2 Changed item (a) from "High RPV pressure 4

Modified to reflect SRNM (7.76 MPaG) and average power range monitor (APRM) not downscale for 3 minutes, or" to "High RPV pressure (7.76 MPaG) and startup range neutron monitor (SRNM) not downscale for 3 minutes, or."

9-3 4

m w

on-

>-n

- a

Differences Between ABWR DCD and SSAR Chapter 9 (Continued)

Item DCD DCD No.

Pages Section Difference Cat.

Reason 18 9.3-22 9.3.7.2 Added last paragraph "outside primary 4

Paragraph lost in an containment a manually-operated valve is Amendment 34 rollover kept closed and locked during normal plant operation. During refueling, the valve is opened to provide air inside containment. A check valve is provided inside the containment."

19 9.3-34 Table 9.3-1 Changed "85.8" to "8.41" in next to last 4

Correction of unit column under Pump Discharge to injection conversion Valve inlet entry.

20 9.4-8 9.4.1.2.3.3(6)

Removed "at E1.7200 in C/B" from end of 4

Wrong elevation sentence.

21 9.4-18 9.4.5.1.3 Added "On a smoke alarm in a division of 4

Lines lost on a Amendment the secondary containment HVAC system, 34 rollover.

the HVAC system shall be put into smoke removal mode. To remove smoke from the secondary "to top of paragraph beginning with containment, the exchaust filter..."

22 9.4-24 9.4.5.4.1.2 In second paragraph changed "46 C" to 4

46.1 C consistent with Tier "46.1 C", changed "45 C" to "50 C" in two 1 Table 5.0 and Tier 2 places.

Table 2.0-1. 45 C/50 C temperature allows cooling from outside air.

23 9.4-27 9.4.5.5.5 Changed "45 C" to "50 C" 4

See reason for item 22 above 9-4

Differences Between ABWR DCD and SSAR Chapter 9 (Continued)

Item DCD DCD No.

Pages Section Difference Cat.

Reason 24 9.5-24 9.5.1.3.9 Replaced last sentence with " Fire detection 4

Consistency with Tier 1 and alarm systems are supplied with power l

from a non-Class 1E uninterruptible power l

supply."

i 25 9.5-59 9.5.12.3.3 Removed probabilities at end of first 2c NRC DCD Guidance paragraph.

26 9A.2-8 and Table 9A.2-1 Changed "SAR" to " Tier 2" at top of fifth 2e NRC DCD Guidance 9A.2-9 column and in note 13.

27 9A.4-53 9A.4.1.1.37(f)

Changed "RCWU" to CUW 4

incorrect acronym 28 9A.4-48 9A i.3.2-6(5)(c)

Changed "with No. 2 fuel oil with min. flash 1

NRC comment

~

point of 377 C" to "with minimum flash of 37.8 C".

29 9A.5-16 9A.S.7 Removed "of the SSAR" in 2 places 2e 9-5 n.

m-

Differenc s Between ABWR DCD and SSAR Chapter 10 o

Pag s S c ion Difference Cat.

Reason None 6

10-1

Differences Between ABWR DCD and SSAR Chapter 11 Item DCD DCD No.

Pages Section Difference Cat.

Reason 1

11.2-1 11.2.1.2 At end of second sentence from bottom, 1

NRC comment

" receiver tank" changed to " sample tank" and "LCW" inserted in front of " sample tanks".

2 11.2-5 11.2.3.1 Changed second line to read: "... effluent 1

NRC comment from the LCW sample tank or the hot shower drain sample tanks as indicated...".

3 11.5-3 11.5.1.2 The middle paragraph - sentence changed 1

NRC comment "10CFR20.6" to "10CFR20.1302" and

" Amendments 1 and 2" to " Attachments 1 and 2".

4 11.5-20 Table 11.5-1 In fifth column under main streamline tunnel 1

NRC comment area deleted "10-13 o 10-e Amps".

t In fifth column under reactor building vent exhaust deleted "10-2 to 102 mR/h".

In fifth column under drywell sump discharge deleted "10-13 o 10-6 Amps".

t In fifth column under offgas pretreatment changed "10-2 to 10 Mgy/h" to "10-2 to 4

104 mGy/h".

11-1

.,,.,..s w,

,,, ~ -

+

y v

Differences Between ABWR DCD and SSAR Chapter 11 (Continued)

Item DCD DCD No.

Pages Section Difference Cat.

Reason 5

11.5-22 Table 11.5-2 in fourth column under plant stack discharge 1

NRC comment (normal range) changed "3.51 x 10-9 cpm per MBq/cm3" to "3.51 x 108 cpm per MBq/cm3" In fifth column under plant stack discharge (normal range) changed "3.7 x 10-4" to 3.7 x 10 MBq/cm3" to "3.7 x 10-9 o 3.7 x 10-3 3

t MBq/cm3".

6 11.5-23 Table 11.5-2 In fifth column under radwaste building 1

NRC comment ventilation exhaust changed "3.7 x 10-7 o t

3.7 x 10-2 MBq/cm3" to "3.7 x 10-9 o 3.7 x t

10-3 MBq/cm3".

7 11.5-23 Table 11.5-2 Designated footnote in fifth column under 1

NRC comment Standby Gas Treatment System Exhaust (added footnote to page 11.5-24).

8 11.5-23 Table 11.5-2 in fourth and fifth column under gland 1

NRC comment seal condenser exhaust discharge changed "3.6 x 106= to "1.33 x 109" and "3.7 x 10-7 o 3.7 x 10-2" to "3.7 x 10-9 o t

t 3.7 x 10-3", respectively.

9 11.5-23 Table 11.5-2 In fourth column under standby gas 1

NRC comment treatment exhaust changed "3.6 x 106" to 9

"1.33 x 10 ".

10 11.5-24 Table 11.5-2 Added footnote "This dynamic range reflects 1

NRC comment post-accident conditions; the entry for expected activity in this row is for the expected normal activity, i.e. non-accident."

11-2

Differences Between ABWR DCD and SSAR Chapter 11 (Continued) item DCD DCD-

~

No.

Pages Section Difference Cat.

Reason 11 11.5-25 Table 11.5-3 in fourth column under reactor building 1

NRC comment cooling water intersystem leakage changed from "3.7 x 10-1 o 3.7 x 10-2 MBq/cm3" to t

"3.7 x 10-7 to 3.7 x 10-2 MBq/cm3".

i i

k i

11-3

.,.._,..m_,

.c%.

.a,.w, m.

..u.....

,,,,,m.#%.

w o.%.

., _.3.

r.,.m...

, _.,,-,,.m..es_

_....m,

~..

..,s

Differences Between ABWR DCD and SSAR Chapter 12 t

item DCD' DCD No.

Pages Section Difference Cat.

Reason l

1 12.0-x List of Figures Added "(Gy/h)" to end of title for 1

NRC comment Figure 12.3-74.

2 12.3-23 12.3.3.1 In first paragraph replaced " Certified Design 2e To make referencing Material (GE document 25AS447)" with consistent

" Tier 1".

3 12.4-9/10 Table 12.4-1 In second column replaced "SSAR" with 2e NRC Guidance

" Tier 2".

i t

t 12-1 i

- ---- u-


m+-

--a.-

a e

l COm G3 T

l i

Q30 1

I l

C

<C

?

LO CO i

l T3 l

C l

G3 I

I O

1 O

G C

M O

v=

C g

G w

l O

O 4

c.

M j

C C3 6

(

O I

94 O

l il:

-O CD m

QO l

Co e

CO z

O I

i C

)

C.9 l

OU Ow CD i

)

m Oe O cn O C Q.

l

$z i

t l

9 I

Differences Between ABWR DCD and SSAR Chapter 14 Item DCD DCD No.

Pages Section Difference Cat.

Reason 1

14.3-1 thru 14.3 Relabedng consistent with change from 2e NRC DCD Guidance 14.3-23 CDM/ SOAR to Tier 1/ Tier 2.

2 14.3-1 14.3 Changed last sentence from "... basis for 3

To more closely follow the NRC authorization to load fuel per the language of Part 52.

provisions of 10 CFR Part 52.103." to

.. basis for the NRC finding under CFR Part 52.103(g)."

3 14.3-12 14.3.2.2 Changed first sentence of item (3) from "As 3

To more closely follow the required by 10CFR52.103, the inspections, language of Part 52.

tests, and analyses must be completed..."

to "The inspections, tests, and analyses are to be completed...".

4 14.3-24 Tables 14.3-1 Right-hand column labeled "SSAR Value" to 2e NRC DCD Guidance thru thru 14.3-10

" Tier 2 Value".

14.3-58 14-1

l Differences Between ABWR DCD and SSAR Chapter 15 Item DCD DCD No.

Pages Section Difference Cat.

Reason l

l 1

15.1-5 15.1.2.1.2.2 Replaced "less than once per 10,000 years.

2c NRC DCD Guidance It" with "so low that it."

2 15.1-8 15.1.3.1.1 Removed "(less than 7x10-5 failure per 2c NRC DCD Guidance reactor year)" in next to last sentence.

3 15.1-8 15.1.3.1.2.1 Replaced "less than 0.0088 times a year" 2c NRC DCD Guidance with "very low frequency".

4 15.1-8 15.1.3.1.2.2 Replaced "less than once per 10,000 years" 2c NRC DCD Guidance with " extremely low".

5 15.2-1 15.2.1.1.1 Deleted "less than 7 x 10-5 failures p[er 2c NRC DCD Guidance reactor year)" from last sentence.

6 15.2-1 15.2.1.1.2.1 Deleted "(0.0088 failures per reactor year)".

2c NRC DCD Guidance 7

15.2-2 15.2.1.1.2.2 Replaced "less than 7 x 10-5 per year" with 2c NRC DCD Guidance

" extremely low".

8 15.2-5 15.2.2.1.1 Deleted "(less than one failure every 11 2c NRC DCD Guidance years)" from next to last sentence.

9 15.2-5 15.2.2.1.2.3 Removed probability numbers (4 places) 2c NRC DCD Guidance 10 15.2-9 15.2.3.1.2.3 Modified paragraph and removed probability 2c NRC DCD Guidance numbers (4 places) 11 15.3-5 15.3.2.1.1 Replaced "(less than 7 x 10-5 failures per 2c NRC DCD Guidance year)" with "very low" in second paragraph.

12 15.3-5 15.3.2.1.2.1 Replaced "about 0.0088 failures per reactor 2c NRC DCD Guidance year" with "very low".

15-1

Differences Between ABWR DCD and SSAR Chapter 15 (Continued)

Item DCD DCD No.

Pages Section Difference Cat.

Reason 13 15.3-8 15.4.5.1.1 Replaced "(less than 7 x 10-5 failures per 2c NRC DCD Guidance reactor year)" with "very low".

14 15.3-8 15.4.5.1.2.1 Replaced "about 0.0088 failure per reactor 2c NRC DCD Guidance year" with "very low".

15 15.4-11 15.4.7.1.2 Replaced numerical value of probability with 2c NRC DCD Guidance

" expected frequency is low".

16 15.4-13 15.4.8.1.2 Removed probability numbers (3 places) 2c NRC DCD Guidance 17 15.6-27 Table 15.6-5 Changed "5.0s" to "5.5s" under isolation 4

inconsistency with text valve closure time 18 15.6-30 Table 15.6-8 Changed "12" to "2" under item IE 4

Correction particulate.

19 15B-17 thru 15B.4 Rewrote introduction to more firmly, 2c NRC DCD Guidance 15B-20 and reference chapter 19 and detected 158-41/42 subsections 158.4.1 through 15B.4.4.2 and Figure 158-8.

20 15D-2 15D.3.1 Removed "(processor failure rate = 10-5/h)"

2c NRC DCD Guidance from the end of item (4) 21 15D-2 15D.3-2 and Revised text to eliminate probability.

2c NRC DCD Guidance 15D.4 22 15D-3 Table 15D-1 and Eliminated figure / table contents and refered 2c NRC DCD Guidance 15D-5 thru Figures 15D-2 thru to SSAR.

15D-8 15D-5 23 15E-15 Tables 15E-12 Replaced "kg/cm2g" with "MPaG" all places.

4 SSAR unit conversion thru 15E-15 incomplete.

I i

15-2

Differences Between ABWR DCD and SSAR Chapter 16 Item DCD DCD No.

Pages Section Difference Cat.

Reason 1

Mult Mult The header and footer on each page are 1

NRC comment changed as follows: The GE document number in the header from the SSAR, 23A6100 Rev. x, is deleted. The SSAR amendment number in the footer is replaced with "Rev. O, Design Control Document /

Tier 2".

2 Mult Mult Where the phrase "of the SSAR" is used to 1

NRC comment describe information in the SSAR, it is replaced with the phrase "of the DCD Tier 2".

3 Mult 4.0 Where the phrase "of the SSAR"is used to 2e DCD NRC Guidance 5.0 describe the applicant's SSAR, it is replaced with the phrase "of the FSAR".

4 Mu!t Mult Where the phrase "in the SSAR, Chapter (or 2

NRC comment Section) x" is used to point to the section of the SSAR, it is replaced with the phrase "in DCD Tier 2, Chapter (or Section) x".

5 Mult Mult Where the phrase "ABWR SSAR analysis" is 1

DCD internal consistency used to describe the safety analyses in the SSAR, it is replaced with the phrase "ABWR safety analysis".

6 Mult Mult Where the phrase " transient or accident 1

DCD internal consistency analysis in the ABWR SSAR" is used with no specific chapter or section reference, it is replaced with the phrase " transient or accident analysis for the ABWR".

16-1

Differences Between ABWR DCD and SSAR Chapter 16 (Continued) ltem DCD DCD No.

Pages Section Difference Cat.

Reason 7

Mult B 3.8 Where the phrase " described in the SSAR" 2e NRC DCD Guidance is used to refer to Chapter 8 of the SSAR, it is replaced with the phrase " described in DCD Tier 2, Chapter 8".

8 Mult Mult Where the phrase " requirement of Section x 2e NRC DCD Guidance of the SSAR" is used to refer to certain requirement specified in the SSAR, it is replaced with the phrase " requirements of DCD Tier 2, Section x".

9 3.7-3, 3.7.1.3, 3.7.2.3, Changed UHS temperature from "37.8 C" to 3

UHS temperature of 3.7-4, 3.7.3.3, and "35 C".

subsection 9.2.5 changed 3.7-8, and B3.7.1 from 37.8 C to 35 C.

83.7-4 10 B 3.3-51 B 3.3.1.1 in item 19, Main Steam Pressure-Low.

3 inconsistent unit Applicable Safety Analyses, LCO, and Applicability, the use of the term "100 F/ hour" is changed to "55 C/h"; the use of the term "785 psig" is changed to "5.41 MPaG". In item 22, Main Steam Tunnel Temperature-High, the term "25 gpm" is changed to "95 ilmin".

11 B3.3-146 B3.3.2.1 From third line in last paragraph removed 4

Correction "one bypassed channel in each division and one" 12 B 3.3-167 B 3.3.4.1 in item 3, SB&PC Reactor Steam Dome 3

Inconsistent unit Pressure-High, Applicable Safety Analysis, LGO, and Applicability, the term "1500 psig" is changed to "10.34 MPaG".

16-2

Diffar;nces Bttween ABWR DCD and SSAR 13 B 3.3-237 B 3.3.8.2 In Background section, the term "135 psig" is 3

Inconsistent unit changed to "0.93 MPaG".

16-3 w

l Differences Between ABWR DCD and SSAR Chapter 17 item DCD DCD No.

Pages Section Difference Cat.

Reason 1

17.0-1 17.0 Deleted "of this Standard Safety Analysis 2e NRC DCD Guidance Report" from first sentence.

17-1

Differences Between ABWR DCD and SSAR Chapter 18 Item DCD DCD No.

Pages Section Difference Cat.

Reason 1

18E-1 18E.1 Added italicized second paragraph and 2a NRC DCD Guidance footnote 2

18E-1 18E.2 and 18E.3 Italicized entire sections and added footnote.

2a NRC DCD Guidance thru 18E-5 3

18E-7 Table 18E-1 Italicized entire table and added footnote 2a NRC DCD Guidance thru 18E-28 4

18E-29 to Italicized entire attachment and added 2a NRC DCD Guidance thru 18E-35 Table 18E-1 footnote 5

18E-36 thru Table 18E-2 Italicized entire tables and added footnote 2A NRC DCD Guidance -

18E-40 thru Table 18E-4 i

I 1

18-1

..m.

. m m

4+

w e--e 4--

I Differences Between ABWR DCD and SSAR I

Chapter 19 Item DCD DCD No.

Pages Section Difference Cat.

Reason 1

19.1-2 19.1.2 Deleted numerical probabilities (4 places).

2c NRC DCD Guidance Substituted word values (2 places).

2 19.2-1 and 19.2.2 and Replaced this SSAR" with " Tier 2" 2e NRC DCD Guidance i

19.2-2 19.2.3.1 3

19.3-1 19.3.1.1 Removed "two events per year. This total 2c NRC DCD Guidance consists of one planned reactor shutdown and one transient which results in reactor scram. The expected number of planned shutdowns is" from the second paragraph.

i Removed "are the same as those used in the GESSARil PRA (Reference 19.3.3) and" from the third paragraph 4

19.3-1 19.3.1.2 Deleted Subsections 19.3.1.2.1 through 2c NRC DCD Guidance 19.3.1.2.3 and inserted statement "not part of DCD (refer to SSAR)".

5 19.3-12 19.3.1.5 Eliminated probability values in first 2c NRC DCD Guidance paragraph.

6 19.3-18 19.3.2.6 Replaced "no more than 10%" wIu5 "a small 2c NRC DCD Guidance percentage" in last paragraph.'

7 19.3-20 19.3.2.12 Replaced "of 1.6E-7 per year" with "is 2c NRC DCD Guidance extremely small".

8 19.3-23, Tables 19.3-1, Deleted frequencies and added footnote 2c NRC DCD Guidance 19.3-29 19.3-4 thru 19.3-6 referring to SSAR.

1 thru-19.3-31 9

19.3-33 Figure 19.3-2 Deleted body of figure and added footnote 2c NRC DCD Guidance referring to SSAR.

19-1 i

l

Differences Between ABWR DCD and SSAR Chapter 19 (Continued)

Item DCD DCD No.

Pages Section Difference Cat.

Reason 10 19.4-3 19.4.2 Removed probabilities in three placed and 2c NRC DCD Guidance inserted word values in two places.

11 19.4-5 19.4.3.1.1 Removed "of the SSAR" two places.

2e NRC DCD Guidance 12 19.4-11 19.4.4 Removed last two sentences of second 2c NRC DCD Guidance paragraph.

13 19.4-12 19.4.4 Eliminated two probability values in last 2c NRC DCD Guidance paragraph.

14 19.4-12 and 19.4.5 Eliminated six probability values.

2c NRC DCD Guidance 19.4-13 15 19.4-13 19.4-6 Replaced "10-7 per year" with "very small".

2c NRC DCD Guidance 15a 19.5-1 19.5-1 Replaced "LPCl" with "RHR".

4 incorrect acronym 15b 19.5-3/4 19.5.3 Deleted " Examining the data in Table 19.3-6, the CCFP Pl is 0.007. Therefore," from the fourth paragraph.

16 19.6-1 19.6.2 and 19.6.3 Eliminated probability values in 5 places.

2c NRC DCD Guidance 17 19.6-3 19.6.5 Eliminated probability values in 2 places in 2C NRC DCD Guidance the next to last paragraph.

18 19.6-4 thru 19.6.7, Eliminated probability values in ten places.

2c NRC DCD Guidance 19.6-5 19.6.8, 19.6.8.1, 19.6.8.3, and 19.6.9 19 19.7-1 19.7.3 Replaced two numerical probabilities with 2c NRC DCD Guidance word values.

19-2 L---- -- ---- --- -- -- --

I Differences Between ABWR DCD and SSAR Chapter 19 (Continued)

Item DCD DCD No.

Pages Section Difference Cat.

Reason 20 19.8-1 19.8 Replaced "the Certified Design Material 2e NRC DCD Guidance (Section 14.3)" with " Tier 1". Inserted "important" in front of " features are addressed by ITAAC..". Modified last setence of second paragraph.

21 19.8-2 thru 19.8 Eliminated all probability values 2c NRC DCD Guidance 19.8-24 22 19.8-24 19.8.7 Changed "Section" to " Attachment" and 2e NRC DCD Guidance deleted "of the ABWR SSAR" under vessel depressurization".

23 19.8-35 Table 19.8-4 Change "(2.15.210)" to "(2.15.10)" under 4

Correction blowout pannels.

24 19.8-41/42 Table 19.8-7 Changed "2% per 100 F" to "2% per 55.6 C" 4

Conversion 25 19.9-7 9.9.10 Replaced "(i.e., less than one foot) and also 4

Clarification prevent accumulation in one area flowing to "with in" under item (3) (b).

26 19.9-7 19.9.11(8)

Removed "with an unavailability of 1E-3 per 2c NRC DCD Guidance demand or less".

27 19.10-3 19.10.5 Deleted second sentence.

2c NRC DCD Guidance 28 19.10-3 and 19.10.7 Deleted "as 0.99" in second sentence, and 2c NRC DCD Guidance 19.10-4 deleted from third setnece on.

29 19.13-3 19.3.5 Deleted second sentence in first paragraph.

2c NRC DCD Guidance 30 19A-1 19A.1 Replaced "SSAR" with " Tier 2" in 2 places.

2e NRC DCD Guidance 19-3

Differences Betwe:m ABWR DCD and SSAR Chapter 19 (Continued)

Item DCD DCD No.

Pages Section Difference Cat.

Reason 31 19A-21 thru Table 19A-1 Changed "SSAR" to " Tier 2" in right hand 2e NRC DCD Guidance 19A-23/24 column 32 198-1 thru Safety issues Changed "SSAR" to " Tier 2" in right hand 2e NRC DCD Guidance 19B-7 Index column.

33 198-8, 19B.2.2 and Replaced "SSAR" with " Tier 2" 2e incomplete units conversion 198-11 19B.2.45 198-80, 19B-83 34 198-77 19.B.2.43 Changed "2.3E+0.4 Kg (23 Tonnes)" to 3

NRC DCD Guidance "2.26 + 05N".

35 198-119 19B.2.68 Removed "For the SSAR" 2e NRC DCD Guidance 36 19C-1/2 19C Replaced " Safeguards information provided 2d NRC DCD Guidance under separate cover" with "This section is not part of the DCD (refer to SSAR)."

37 19D-1/2 19D Removed entire Appendix 19D and replaced 2c NRC DCD Guidance with "This section not part of the DCD (refer to SSAR)."

38 19E.1-1/2 19E.1 Deleted "primarily" in front of the word 2c NRC DCD Guidance deterministic in the first line 39 19E.2-11 19E.2.1.2.3, Modified statement pertaining to 2c NRC DCD Guidance thru 19E.2.1.2.3.1.1, probabilities.

19.E.2-13 19E.2.1.2.3.1.2 19E.2.1.2.3.1.3 40 19E.2-15 19E.2.1.2.3.2.1 Replaced "LPCl" with "LPFL".

4 Correction l

19E.2-19 19E.2.1.2.3.3 19-4

.m

.m..

.m.

Diff renc s Between ABWR DCD and SSAR Chapter 19 (Continued)

Item DCD DCD No.

Pages Section Cifference Cat.

Reason 41 19E.2-19 19E.2.1.2.3.3(2)

Deleted "of the SSAR" 2e NRC DCD Guidance 42 19.E.2-22 19E.2.1.2.3.3(10)

Added " exceed"in front of "0.46 MPa".

4 Correction 43 19E.2-25 19E.2.1.3.3 Modified second sentence to eliminate 2c NRC DCD Guidance failure rate and melded the second and third sentence for clarification.

44 19E.2-32 19E.2.1.5.2.7, Eliminated probability values and replaced 2c NRC DCD Guidance thru 19E.2.1.5.2.13, them with word values.

19E.2-36 19E.2.1.5.3.1, 19 E.2.1.5.3.2, 19E.2.1.5.3.3 45 19E-36 19E.2.2 Eliminated probability values and replaced 2c NRC DCD Guidance 19E-37 19E.2.2.1 them with word values.

19E-44 19E.2.2.2 19E-46 19E-48 19E-49 46 19E-52 19E.2.2.3 Replaced probnbility values with word 2c NRC DCD Guidance 19E-54 19E.2.2.5 values.

19E-55 19E.2.2.6 19E-56 19E.2.2.8 19E-57 19E-60 19E-61 47 19E.2-73 19E.2.3.3.1 Replaced numerical values of probability 2c NRC DCD Guidance 19E.2-77 with word values 19-5

Diff renc;s Between ABWR DCD cnd SSAR Chapter 19 (Continued)

Item DCD DCD No.

Pages Section Difference Cat.

Reason 48 19E.2-82 19E.2.3.3.3(2)

Eliminated numerical probabilities in items 2c NRC DCD Guidance 19E.2-83 (a), (b), (e), (f), (g), (h), (i), and (k).

19E.2-84 49 19E.2-85 19E.2.3.3.3(4)

Modified first paragraph to eliminate 2c NRC DCD Guidance probabilities.

50 19E.2-86 19E.2.3.3.4 Modified items (1) and (2) to eliminate 2c NRC DCD Guidance 19E.2-87 probabilities.

19E.2-88 19E.2-89 51 19E.2-101 19E.2.3.5.3.4 Deleted "the ABWR SSAR" from the first 2e NRC DCD Guidance sentence.

52 19E.2-105 19E.2.3.6.1 Replaced numerical values of probability 2c NRC DCD Guidance 19E.2.107 19E.2.3.6.4 with word values.

53 19E.2-108 19E.2.4 Replaced "no" with "early"in second 4

Clarification sentence.

54 19E.2-128 19E.2.6.5.2 Replaced numerical values of probabilities 2c NRC DCD Guidance 19E.2-129 19E.2.6.7 with word values.

19E.2-131 19E.2.6.9 19E.2-132 19E.2.6.10 19E.2-137 19.E.2.7.2 19E.2-138 19E.2.7.3 19E.2-140 19E.2.8.1 19E.2-141 19E.2.8.1.1 19-6 m

Diffsrenc:s Betwe:n ABWR DCD and SSAR Chapter 19 (Continued)

Item DCD DCD No.

Pages Section Difference Cat.

Reason 54 19E.2-142 19E.2.8.1.2 (cont) 19E.2-143 19E.2.8.1.4 19E.2-144 19E.2.8.1.7 19E.2-146 19E.2.8.2.7 19E.2-152 19E.2-153 55 19E.2-174 Table 19E.2-20 Eliminated probabilities and added note 2c NRC DCD Guidance 19E.2-175 19E.2-21

" probabilities not part of DCD (refer to 19E.2-184 19E.2-26 SSAR)".

19E.2-185 19E.2-27 19E.2-28 56 19E.3-259 Figures 19E.2-19a Removed information from body of figures 2c NRC DCD Guidance thru thru 19E.2-22 and added note "Not part of DCD (refer to 19E.2-274 SSAR)".

57 19E.3-1 19E.3.1.1 Replaced "98.6%" with "a very large 2c NRC DCD Guidance percentage" in second paragraph.

58 19E.3-3 19E.3.2.2 Replaced "the SSAR" with " Tier 2" in first 2e NRC DCD Guidance paragraph.

59 19E.3-6 Table 19E.3-1, Removed probabilities and added note 2c NRC DCD Guidance 19E.3-9 19E.3-6 and

" Probabilities not part of DCD (refer to 19E.3-10 19E.3-7 SSAR)".

60 19E.3-11 Figure 19E.3-1 Removed body of figure and added note 2c NRC DCD Guidance

" Figure is not part of DCD (refer to SSAR)".

19-7

Differences B tw;cn ABWR DCD and SSAR Chapter 19 (Continued)

Item DCD DCD No.

Pages Section Difference Cat.

Reason 61 19EA-5 19EA.2.1.3 Removed numerical probabilities and, where 2c NRC DCD Guidance 19EA-7 19EA.2.1.5 applicable, replaced with word values.

19EA-9 19EA.2.1.6 19EA-10 19EA-11 62 19EA-24 19EA.3.6.2 Removed numerical probabilities and, where 2c NRC DCD Guidance 19EA-27 19EA-4.1 applicable, replaced with word values.

19EA-28 19EA-4.2 19EA-4.2.1 63 19EA-32 Figures 19EA-1 Deleted body of figures and added note 2c NRC DCD Guidance thru thru 19EA-6,

" Figures not part of DCD (refer to SSAR)".

19EA-37, 19EA-8 and 19EA-39 19EA-9 19EA-40 19EA-14 19EA-45 19EA-15 19EA-46 64 19EB-2 19EB.1.1 Replaced numerical probabilities with word 2c NRC DCD Guidance 19EB-3 values.

65 19EC-4 19EC.2.1.1 Removed probabilities and added note 2c NRC DCD Guidance

" Probabilities not part of DCD (refer to SSAR)".

19-8 m-

..m..

Diff rences Between ABWR DCD and SSAR Chapter 19 (Continued)

Item DCD DCD No.

Pages Section Difference Cat.

Reason 66 19EC-5 19EC.2.1.2 Removed numerical probabilities and, where 2c NRC DCD Guidance thru 19EC.2.1.3 applicable, replaced with word values.

19EC-14 19EC.2.1.5 19EC.2.1.6 19EC.2.1.7 19EC.2.2.2 19EC.2.2.3 19EC.2.2.4 19EC.2.2.5 67 19EC-29 Figures 19EC-1 Removed body of figures and added note 2c NRC DCD Guidance 19EC-30 19EC-2

" Probabilities not part of DCD (refer to 19EC-36 18EC-8 SSAR)".

68 18EE-3 19EE.2.1 Removed vacuum breaker related 2c NRC DCD Guidance 19EE-5 19EE.2.2 probabilities 19EE-6 19EE.2.3 69 19EE-11 19EE.4.1 Replaced numerical probabilities with word 2c NRC DCD Guidance 19EE-12 19EE.4.4 values.

19EE-13 19EE.5 70 19EE-17 Table 19EE-2 Removed probabilities and added note 2c NRC DCD Guidance

" Probabilities not part of DCD (refer to SSAR)".

71 19EE-16 Figures 19EE-1 Removed body of figures and added note 2c NRC DCD Guidance 19EE-17/18 and 19EE-2

" Probabilities not part of DCD (Referto SSAR)".

72 19FA-1/2 19FA Removed attachment 19FA and added note 2c NRC DCD Guidance "This attachment is not part of the DCD (refer to SSAR)."

19-9

Diff:rences Betw:en ABWR DCD and SSAR Chapter 19 (Continued) ltem DCD DCD No.

Pages Section Difference Cat.

Reason 73 19H-14 19H.3.3 Deleted last sentence of first paragraph.

2c NRC DCD Guidance 74 19H-15 19H.4.2 Deleted last sentence of last paragraph and 2c NRC DCD Guidance last sentence of fourth to last paragraph.

75 19H-17 19H.5.1 Changed "the SSAR" to " Tier 2" and 2e NRC DCD Guidance "lTAAC" to " Tier 1".

76 19H-23 Table 19H-1 Changed " probability" to " fragility" in footnote 2c NRC DCD Guidance 1 and modified footnote 5 eliminate specific values.

77 19H-24 Table 19H-2 Removed fragilities and added note " Fragility 2c NRC DCD Guidance thru thru 19H-10 not part of DCD. Refer to SSAR".

19H-32 78 191-2 1 91.2 Removed fragilities and corresponding 2c NRC DCD Guidance 1 91-3 191.3.2 probabilities.

1 91-4 191.3.3 1 91-5 191.4 1 91-8 191.5.2 1 91-9 191.6 191-10 191.7 79 191-11 Table 191-1 Removed fragilities and HCLPF values from 2c NRC DCD Guidance 191-12 table and extended note to read " Fragilities 191-13 and HCLPF values are not part of DCD (refer to SSAR)".

80 191-14 Table 191-2 Remove body of tables and added note 2c NRC DCD Guidance "This table is not part of DCD (refer to SSAR)".

19-10

Diff:rences B;twacn ABWR DCD and SSAR

. Chapter 19 (Continued) l Item DCD DCD No.

Pages Section Difference Cat.

Reason 81 191-15 Table 191-3 Fragilities and HCLPF values deleted from 2c NRC DCD Guidance table and added note " Fragilities and HCLPF values are not part of DCD (refer to SSAR)."

l 82 191-16 Table 191-4 Body of table deleted and added note "This 2c NRC DCD Guidance table is not part of DCD (refer to SSAR)".

83 191-17/18 Figures 191-1 Deleted figures and added note " Figures 2c NRC DCD Guidance thru 191-25 191-1 through 191-25 are not part of DCD (refer to SSAR)".

84 19K-2 19K.3 Replaced numerical probability valves with 2c NRC DCD Guidance 19K-5 19K.5 word valves.

19K-8 19K.11.1 19K-12 19K.11.5 19K-17 19K.11.14 85 19K-19 Tables 19K-1, Removed numerical values from tables and 2c NRC DCD Guidance thru 19K-2 and 19K-3 added note "Not part of DCD (refer to 19K-21 SSAR)"

86 19K-22 thru Table 19K-4 Removed numerical values in right hand 2c NRC DCD Guidance 19K-31/32 column and added note "Not part of DCD (refer to SSAR)".

87 19L-1 19L3 Replaced "the ABWR Safety Analysis Report 2e NRC DCD Guidance (SSAR)" with "TiG 2".

88 19L-2 189L3 Replaced numerical probability value with 2c.

NRC DCD Guidance i

word value.

89 19L-3 19L.4.2 Removed "SSAR".

2e NRC DCD Guidance l

90 19L-8 19L.5.3 Removed last sentence from item (3).

4.

Clarification / correction 19-11

Diff rences Between ABWR DCD and SSAR Chapter 19 (Continued)

Item DCD DCD No.

Pages Section Difference Cat.

Reason 91 19L-8 19L.5.3 Removed probability statement in last 2c NRC DCD Guidance paragraph.

92 19L-8 15L.5.4 Changed " third" to "second" in first item (1).

4 Correction 93 19L-20 19L.7.3 Changed "one" to "two" diesel generations at 4

Correction end of first paragraph and deleted "one" underitem (b).

94 19L-21 19L.7.3 Deleted proabilities in second paragraphs.

2c NRC DCD Guidance 95 19L-21/22 19L.8.2 Deleted "SSAR".

2e NRC DCD Guidance 19L.8.3 96 19L-23 19L.8.4 Replaced numerical values of probabilities 2c NRC DCD Guidance 19L-24 19L.9.2 with word values.

97 19M-1 19M.1 Replaced numerical probability values with 2c NRC DCD Guidance 19M-2 19M.3 word values.

19M-3 19M.4.1.1 19M-7 19M.4.2.5 19M-8 98 19M-9 19M.5.2 Removed frequencies and added note "Not 2c NRC DCD Guidance 19M-10 part of DCD (refer to SSAR)".

99 19M-10 19M.6.2 Replaced numerical values of probabilities 2c NRC DCD Guidance 19M-11 with word values.

19M-12 100 19M-13 Table 19M-1 Removed frequencies and added note "Not 2c NRC DCD Guidance 19M-33 19M-11 part of DCD (refer to SSAR)".

thru 19M-12 19M-35 19M-13 19M-14 19-12

Diff:rcnces Bstwe n ABWR DCD and SSAR Chapter 19 (Continued)

Item DCD DCD No.

Pages Section Difference Cat.

Reason 101 19M-16 Table 19M-3 Deleted body of tables and added note "Not 2c NRC DCD Guidance thru thru part of DCD (refer to SSAR)".

19M-33 Table 19M-5 102 19M-38 Figure 19M-3 Deleted body of figures and added note "Not 2c NRC DCD Guidance thru thru 19M-13 a part of DCD (refer to SSAR)".

19M-48 103 19N-1 19N.1 Removed numerical probabilities.

2c NRC DCD Guidance 19N-12 19N.S.1 19N-13 104 19N-15 19N.5.4.2 Replaced numerical probabilities with word 2c NRC DCD Guidance 19N-17 19N.6 values.

19N-18 19N.7 105 Mui 19P Removed Appendix 19P in its entirety and 2c NRC DCD Guidance added note "Not part of DCD (Refer to SSAR) 106 190-2 190.2 In last paragraph replaced "the SSAR" with 2e NRC DCD Guidance

" Tier 2" and replaced "the Inspections, Test, Analysis, and Acceptance Criteria (ITAAC Requirement)" with " Tier 1".

107 190-3 190.3 Replaced numerical probability values with 2c NRC DCD Guidance 190-4 word values.

19-13

k Diffsrences Betwocn ABWR DCD and SSAR Chapter 19 (Continued) item DCD DCD No.

Pages Section Difference Cat.

Reason 108 190-21 190.6 Replaced numerical probability values with 2c NRC DCD Guidance 190-23 190.7.2 word values.

190-25 190.7.3 190-26 190.7.5 190-31 190.7.9.1 190-33 190.7.9.3 190.7.9.4 190.7.9.5

- 109 190-45 190.12.4 Removed unavailability values from table 2c NRC DCD Guidance and added note "Not a part of DCD (refer to SSAR)."

110 190-57 Figures 190-1 Removed all figures and replaced with note 2c NRC DCD Guidance thru thru 190-19

" Figures 190-1 through 190-19 are not part 190-75/76 of DCD (refer to SSAR)".

111 190A-1 Figures 190A-1a Removed all figures and replaced with note 2c NRC DCD Guidance thru thru 190A-20 ck

" Figures 19A-la through 190A-20 ck are not 190A-412 part of DCD (refer to SSAR)".

112 1908-5 Tables 1908-3 Removed probabilities and added note "Not 2c.

NRC DCD Guidance 1908-6 190B-4 part of DCD (refer to SSAR)".

113 190C-29 Table 190C-2 Removed "ABWR"in fifth column under 4

Correction Susquehanna 1 entry.

114 19R-1 19R.1 Replaced numerical values of probability 2c NRC DCD Guidance 19R-2 with word values.

19R-3 115 19R-4 19R4.4 Replaced "SSAR" with " Tier 2".

2c NRC DCD Guidance 19R-24 19.R.5.4.2 19-14

k Diff:renc s Between ABWo. DCD and SSAR Chapter 19 (Continued)

Item DCD DCD No.

Pages Section Difference Cat.

Reason 116 19R-9 19R.4.3 Replaced "2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />" with "several hours" in 2c NRC DCD Guidance fourth paragraph.

117 19R-21 19R.S.3 Replaced numerical probabilities with word 2c NRC DCD Guidance 19R-22 19R.5.4.1 values.

19R-25 19R.5.4.2 19R-27 19R.5.5.1 19R-28 19R.5.5.2 19R-29 19R.6.1 19R-30 19R.6.4 19R-31 19R.6.6 118 19R-31 19R.6.5 Deleied reliability goals and added note "Not 2c NRC DCD Guidance a part of DCD (refer to SSAR)".

119 19R-35 Tables 19R-3 Frequency / probability deleted and added 2c NRC DCD Guidance thru 19R-37 thru 19R-6 note "Not a part of DCD (refer to SSAR)".

120 19R-47 thru Figures 19R-7 thru Removed body of figures and added note 2c NRC DCD Guidance 19R-53/54 19R-13

" Note a part of DCD (refer to SSAR)".

19-15

Differences Betwenn ABWR DCD and SSAR Chapter 20 Item DCD DCD No.

Pages Section Difference Cat.

Reason 1

20.1-1 20.0 Added new paragraph on relationship of 2e NRC DCD Guidance SSAR and Tier 2 " names" in Chapter 20.

2 20.3.8-37 Response 420.69 Italicized item (1) and added footnote.

2a NRC DCD Guidance 3

20.3.8-51 Response 420.92 Italicized third and last paragraphs of 2a NRC DCD Guidance and response and added footnotes.

20.3.8-52 4

20.3.12-5 Response 725.66 Removed event / frequency table from end of 2c NRC DCD Guidance response.

5 20.3.15-37 Responses 910.17 Changed notation " Response to this 2d NRC DCD Guidance thru thru 910.15 question is provided under separate cover" 20.3.15-39 to " Safeguards information not part of DCD (see SSAR Subsection 20.3.15)".

6 20.3.9-1 Responses 725.1 Deleted responses and added " Response to 2c NRC DCD Guidance thru thru 725.61 Chapter 19" questions not part of DCD (see 20.3.9-SSAR Subsection 20.3.9)".

15/16 7

20.3.11-10 Responses Deleted responses and added " Response to 2c NRC DCD Guidance thru 420.131 thru Chapter 19 questions not part of DCD" (See 20.3.11-420.135 SSAR Subsystem 20.3.11).

11/12 8

20.3.12-1 Responses 725.62 Deleted responses and added " Response to 2c DCD Guidance thru thru 725.94 Chapter 19 questions not part of DCD" (see 20.3.12-SSAR Subsection 20.3.12).

9/10 9

20.3.14-29 Responses 621.1 Deleted responses and added " Response to 2c DCD Guidance thru through 621.11 Chapter 19 questions not part of DCD" (see 20.3.14-32 SSAR Subsection 20.3.14).

20-1

Differences Between ABWR DCD and SSAR Chapter 21 Item DCD DCD No.

Pages Section Difference Cat.

Reason 1

2',-35 and Figures 1.2-25, Changed figure to show 3 TCW heat 3

Figure 1.2-25 inconsistent 21-26 1.2-26 exchangers and pumps, with text and Figure 9.2-6a.

t--

2 21-103 and Figures 5.4-10 Italicized note 32 and 29, respectively and 2a NRC DCD Guidance 21-127 (Sheet 1) and added footnotes.

6.3-7 (Sheet 1) 3 21-5:6 Figure 9.2-1 Removed RCW from lower right-hand of 3

Conflicting figures show Sheet 9 figure.

TGSC cooled by both RWC system and condensate feedwater system.

Traditional is with condensate feedwater system and agrees with URD requirements.

)