ML20137N734

From kanterella
Jump to navigation Jump to search
Effluent Monitoring Rept for Final Six Months of 1996, for Lynchburg Mfg Facility Site in Lynchburg,Va
ML20137N734
Person / Time
Site: 07001201
Issue date: 12/31/1996
From: Elliott G
FRAMATOME
To:
References
NUDOCS 9704090043
Download: ML20137N734 (3)


Text

.

}.

%g7 / y' s$.

y y,ys-Y, h%',.

'F RhM ATOM E COG EM A F U E LS p &pt

~

M February 27,1997

.(y Director, Radiation Safety & Safeguards Region 11 United States Nuclear Regulatory Commission Suite 2900 101 Marietta Street Atlanta, GA 30323

Reference:

. SNM-1168, Docket 70-1201 Gentlemen:

In accordance with the provisions of 10CFR70.59, Framatome Cogema Fuels submits the attsched afiluent monitoring report for the final six months of the year 1996 for our Lynchburg Manufacturing l'acility site located in Lynchburg, Virginia.

j i

You may contact me at (804)832-5202 should you have any questions or require additional information.

Sincerely,-

_ _ /__.

.,y le F. Elliott, Manager Safety & Licensing Enclosures

.\\

cc:

Ms. Elizabeth Q. Ten Eyck, Director p

Division of Fuel Cycle Safety & Safeguards g

Oflice of Nuclear Material Safety & Safeguards 9

l United States Nuclear Regulatory Commission Washington, D.C. 20555 Mr Thomas W. Stone, Jr.

Department ofHealth Bureau ofIndustrial Hygiene 109 Governor Street Richmond, VA 23219 9704090043 961231.

PDR ADOCK 07001201 C

PDR

- Framatome Cogsma Fuels FRAMATOME' P.O. Bos 11646, Lynchburg. VA 245061646 "t

YtCHHoLooIt5

' Tolophone: 804 832 5000 Fax: 804-832 5167

o' aa Semi-Annual Gaseous Effluent Report j

Paga 1 of 2 1.

Main Stack (PLR/ SERF-1 RCA) a.

Reporting Period..................: 07/01/96 to 12/31/96 b.

Location of Sample Collection.. CNFP Main Stack----

c.

Stack Flow Rate.....

.............: 10250 CFM

\\.9 l 2-DL G

Radioactivity Released Gross Alpha: 4-G46 Ci

  • g Gross Beta : 9.968 Cl jf Y

ho10Re_

Quantity (uCi)_ Concentration (uCl/ml)

%DAC r

~

234U 1.490 1.93E-14 8.51 235U 0.083 1.07E-15

1. 9 23eU 0.346 4.47E-15 7.45 "Co 9.968 1.29E-13 0.25 ll.

SERF-2 Radiologically Controlled Area a.

Reporting Period................... 07/01/96 to 12/31/96 b.

Location of Sample Collection... SERF-2 Main Stack c.

Stack Flow Rate.,..................: 937 Radioactivity Released Gross Alpha: Not Applicable Gross Beta : 0.698 Ci Isotope _

Quanti.tv (uCi)

Concentration (uCi/ml)

%DAC "Co 0.698 1.62 E-13 0.20 lli. SERF-3 Radiologically Controlled Area a.

Reporting Period.................

07/01/96 to 12/31/96 b.

Location of Sample Collection.. SERF-3 Main Stack c.

Stack Flow Rate........................: 4145 CFM Radioactivity Released Gross Alpha: Not Applicable Gross Beta : 8.462 uCi lssione_

Quantity (uCi)

Concentration (uCi/ml)

%DAC "Co 8.462 2.80 E-13 0.56

,i 9

  • Faga 2 cf 2 3+

IV ' SERF'-4 Radiologically Controlled Area

'f a.

Reporting Period.....................: 07/01/96 to 12/31/96 b.

Location of Sample Collection..: SERF-4 Main Stack c.

Stack Flow Rate.'.......................: 10000 CFM Radioactivity Released Gross Alpha: Not Applicable Gross Beta : 14.278uCi Isotone Quantity (uCl) Concentration (uCi/ml)

%DAC "Co 14.278 1.93 E-13 0.39 t

M i

\\

l

,