'NUREG-1127 Radiation Protection Training at Uranium Hexafluoride and Fuel Fabrication Plants U.S. Nuclear Regulatory Commission Office of Nuclear Regulatory Research A. Brodsky, A. L. Soong, J. Bell Y
Ul gins /3
%,,y,,/
gjj8n"""';
i NOTICE Availability of Reference Materials Cited in NRC Publications Most documents cited in NRC publications will be available from one of the following sources:
- 1. The NRC Public Document Room,1717 H Street, N.W.
Washington, DC 20555
- 2. The Superintendent of Documents, U.S. Government Printing Office, Post Office Box 37082, Washington, DC 20013 7982
- 3. The National Technical Information Service, Springfield, VA 22161 Although the listing that follows represents the majority of documents cited in NRC publications, it is not intended to be exhaustive.
Referenced documents available for inspection and copying for a fee from the NRC Public Docu-ment Room include NRC correspondence and internal NRC memoranda; NRC Office of Inspection and Enforcement bulletins, circulars, information notices, inspection and investigation notices; Licensee Event Reports; vendor reports and correspondence; Commission papers; and applicant and licensee documents and correspondence.
The following documents in the NUREG series are available for purchase from the NRC/GPO Sales Program: formal NRC staff and contractor reports, NRC-sponsored conference proceedings, and NRC booklets and brochures. Also available are Regulatory Guides, NRC regulations in the Code of Federal Regulations, and Nuclear Regulatory Commission Issusaces.
Documents available from the National Technical Information Service include NUREG series reports and technical reports prepared by other federal agencies and reports prepared by the Atomic Energy Commission, forerunner agency to the Nuclear Regulatory Commission.
Documents available from public and special technical libraries include all open literature items, such as books, journal and periodical articles, and transactions. Federal Register notices, federal and state legislation, and congressional reports can usually be obtained from these libraries.
Documents such as theses, dissertations, foreign reports and translations, and non-NRC conference proceedings are available for purchase from the organization sponsoring the publication cited.
Single copies of NRC draf t reports are available free, to the extent of supply, upon written request to the Division of Technical Information and Document Control, U.S. Nuclear Regulatory Com-mission, Washington, DC 20555.
Copies of industry codes and standards used in a substantive manner in the NRC regulatory process are maintained at the NRC Library, 7920 Norfolk Avenue, Bethesda, Maryland, and are available there for reference use by the public. Codes and standards are usually copyrighted and may be purchased from the originating organization or, if they are American National Standards, from the American National Standards Institute,1430 Broadway, New York, NY 10018.
1 l
l i
NUREG-1127 Radiation Protection Trainina at Uranium Hexafluoride and Fuel Fabrication Plants I
Minuscript Completed: April 1985 D:ts Published: May 1985 A. Brodsky, A. L. Soong, J. Bell Divi;; ion of Radiation Programs and Earth Sciences Office of Nuclear Regulatory Research U.S. Nuclear Regulatory Commission W:shington, D.C. 20666
/* "%,,,
Y s
This document does not impose requirements.
F Abstract This report provides general information and references useful for establish-ing or operating radiation safety training programs in plants that manufacture nuclear fuels, or process uranium compounds that are used in the manufacture of nuclear fuels.
In addition to a brief summary of the principles of effec-tive management of radiation safety training, the report also contains an appen-dix that provides a comprehensive checklist of scientific, safety, and manage-ment topics, from which appropriate topics may be selected in preparing train-ing outlines for various job categories or tasks pertaining to the uranium nuclear fuels industry. The report is designed for use by radiation safety training professionals who have the experience to utilize the report to not cnly select the appropriate topics, but also to tailor the specific details gnd depth of coverage of each training session to match both employee and management needs of a particular industrial operation.
l l
l l
l l
l l
f l
l iii
TABLE OF CONTENTS Page Chapter iii Abstract...............................................................
1 1.
INTRODUCTION......................................................
2.
GENERAL CONSIDERATIONS IN ORGANIZING A RADIATION PROTECTION 1
TRAINING PR0 GRAM..................................................
1 2.1 Establishing Training Needs..................................
2 2.2 Training Methods.............................................
2 2.3 Management 0versight.........................................
2.4 Who Should Receive Radiation Protection Training.............
2 3
2.5 When Trai ni ng Shoul d 0ccur...................................
3 2.6 Training Eva1uatisn..........................................
2.7 What Records of Training Should Be Maintained................
4 3.
ELEMENTS OF A RADIATION PROTECTION TRAINING PROGRAM...............
5 5
3.1 0bjectives...................................................
5 3.2 Content......................................................
6 3.3 Training with Mockups........................................
3.4 Roles of Radiation Protection Staff..........................
6 Table 1 Subjects That May Be Included in Training Programs for Employees of Uranium Hexafluoride and Fuel Fabrication 7
P1 ants.......................................................
22 T&ble 2 Student Evaluation of Course.................................
_T&ble 3 Student Evaluation of Instructor.............................
23 24 REFERENCES.............................................................
i i
4 e
V i.
S' 1.
INTRODUCTION For licensees of the U.S. Nuclear Regulatory Commission, Section 19.12,
" Instructions to Workers," of 10 CFR Part 19, " Notices, Instructions and Reports to Workers; Inspections," requires that individuals be given instruc-tion in radiation protection that is commensurate with the potential radiation protection problems that they may encounter in restricted areas as defined in paragraph 19.3(e) of 10 CFR Part 19 (1).
Paragraph 20.1(c) of 10 CFR Part 20,
" Standards for Protection Against Radiation," states that occupational radia-tion exposure should be kept "as low as is reasonably achievable" (ALARA) (2).
Appropriate training, with the objective of providing the worker with sufficient knowledge of radiation protection principles applicable to his work with radio-active materials, is essential for keeping radiation exposure ALARA.
In the United States, existing uranium fuel plants have already developed training programs to meet these needs.
This document has been developed by NRC staff in cooperation with, and incorporating the ideas and experience of, radiation safety professionals and training officers in the nuclear fuels industry.
The purpose of the document is to provide a readily accessible, organized, source of training information to assist the industry in maintaining its high safety standards with additional convenience and consistency.
The report is designed for use by experienced industry professionals who can select topical material and match the level of technical coverage to specific industry operating jobs and tasks. It provides basic information and a topical list for developing or updating radiation protection training (RPT) consistent with the ALARA objective, consistent with effective industrial. safety manage-ment, and consistent with training programs already accepted by NRC staff for meeting the training requirement of 10 CFR Part 19, for individuals who work at uranium fuel fabrication or uranium hexafluoride production plants (abbre-viated UHFFPs).
Although a list of topics is provided (see Table 1), this document does not provide detailed training programs and lesson plans for each plant, since the industrial training manager in each plant is best qualified to design specific programs for his plant.
NCRP Report No. 71 (1) provides general guidance for planning and conducting training programs.
General principles of radiation safety training and an outline of topics pertaining to UHFFPs are given in this report.
Regulatory Guide 8.10, " Operating Philosophy for Maintaining Occupa-tional Exposures As Low As Is Reasonably Achievable," may provide information useful for training in the philosophy and management principles related to the ALARA concept.
2.
GENERAL CONSIDERATIONS IN ORGANIZING A RADIATION PROTECTION TRAINING PROGRAM 2.1 Establishing Training Needs*
In determining appropriate radiation protection training (RPT) for an individual, the following should be considered:
- The training needs for an escorted visitor or a short-term worker who is to be escorted by a worker who has had appropriate RPT may be abbreviated, but the use of escorts must not be used to circumvent timely appropriate training required by 10 CFR Part 19.
1
1.
Primary duties and responsibilities.
2.
Secondary duties and responsibilities.
3.
Previous experience.
4.
Previous training.**
2.2 Training Methods Training should consist of classroom training, on-the-job training, and a mecha-nism to evaluate and document the effectiveness of the training received.
Train-ing should be conducted by qualified personnel.
Training should be conducted in such a manner that the individual being trained knows the specific objectives of the training and receives feedback on his or her performance in meeting the training objectives.
2.3 Management Oversight The RPT program should be periodically reviewed by facility management with input from the radiation protection manager.
The radiation protection manager should remain cognizant of the RPT program.
Changes in training needs warranted by changes in operations, license conditions, and regulations should be imple-mented promptly.
Review of the RPT program should include a review of training documentation and performance records.
2.4 Who Should Receive Radiation Protection Training The radiation protection training program should include all personnel, includ-ing supervisors, whose duties require them to work in, or frequently enter restricted areas, whether or not they are employees of the licensee.
This includes visitors and transient workers.
It also includes secretaries and others who normally would not work in restricted areas but may occasionally have need to enter such areas.
They should know the precautions necessary to avoid undue radiation exposure or the spread of contamination to themselves and others.
Visitors may be defined as people who enter the plant for purposes other than to work for the licensee and who are not expected to receive radiation doses, although they may enter restricted areas incident to their activities (e.g.,
salespersons or students).
Transient workers may be defined as people who enter the plant to work in re-stricted areas for a definite but limited period of time and who are directly involved in plant operations, maintenance or repair, or the direct support of i
these activities (whether or not they are employees of the licensee).
Examples
]
of transient workers are equipment manufacturers' representativos, individuals employed in short-term maintenance and repair work, vendor personnel employed to temporarily augment the radiation protection staff, transport workers, and licensee employees temporarily assigned to the UHFFP.
Transient workers should receive on-site plant-specific training specific to 4
their job assignments, as well as a background of training in the more general J
1 1
^^The appropriateness of previous training should be assessed by a performance test, a written test, oral examination, or inquiry to the organization that gave the training.
In most cases, site-specific training will be a necessary supplement to an individual's previous training.
The appropriateness of previous training should be documented.
2 i
j
(non plant specific) areas of radiation protection, to meet the requirements of 10 CFR Part 19(1).
2.5 When Training Should Occur Prior to working in a restricted area, each individual should be trained in all tspects of radiation protection necessary to his or her immediate duties.
In tddition, those persons who will routinely work in restricted areas should receive instructions at their job sites concerning the radiation protection espects of their jobs.
Appropriate RPT for each individual should be conducted in accordance with a schedule established by the licensee.
Classroom training and on-the-job train-ing may be intermixed.
New employees should be accompanied by a trained escort, specially supervised, or provided other precautions to ensure that an individual is not subject to risks from situations for which he has not yet been fully trained.
Individuals should receive formal periodic refresher RPT each year.
Such train-ing should not be a simple repetition of previous training.
It should include cppropriate topics addressing the needs of the worker, changes in facility operations, and changes in methods of radiation protection directly relevant to their duties and responsibilities.
Training / retraining needs should be eval-uated when a worker is reassigned to a former job or is assigned to a job with significantly different duties and responsibilities, and training / retraining should be conducted if warranted.
In general, an individual reassigned to a job from which he/she has been absent for over a year should be retrained.
Besides the formal RPT and retraining, there should be a mechanism to communi-cate radiological protection developments, changes in procedures, and changes in plant operations through informal meetings.
Such meetings should allow workers opportunity to discuss perceived radiation protection problems directly with radiation protection staff.
1 2.6 Training Evaluation The RPT program should include appropriate mechanisms for evaluating its effec-tiveness.
Mechanisms for evaluating the knowledge and understanding gained by the employee may consist of a written exam, an oral interview, and an on-the-job performance evaluation.
The extensiveness of the testing or mechanisms should be related to the needs for training (i.e., potential hazard of the work for which the worker is being trained).
The training and testing of a secretary or a visitor touring a restricted area differ from that appropriate for a worker whose entire duties are to be conducted within a restricted area on a full-time basis.
I In all forms of evaluation, there should be ways to formally document the mate-rials covered, the tests and evaluations, and the feedback given to the employee.
In on-the-job evaluations and oral evaluations, a check list or similar device should be used for the documentation of the feedback received from the employee for each question.
Evaluation mechanisms should emphasize the most important l
parts of the RPT (i.e., the skills and knowledge directly related to the specific job's day-to-day practices and emergency procedures).
A high percentage should be used (some plants use 80 percent) to determine a passing score for written 3
and oral examinations.
Practical or on-the-job evaluations may be graded on a
. pass / fail basis.
The first remedy for a failing score is retraining and reevaluation.
Additional test features should:
1.
Stress the importance of safety in a controlled area.
2.
Assess the individual's attitude toward the rights and obligations of a controlled area worker.
3.
Reinforce the key points of training.
4.
Demonstrate the ability to recognize and cope with radiation hazards, and to apply radiation protection principles in actual situations at the facility.
Besides the formal evaluation procedures, a mechanism should exist for super-visors and radiation protection personnel to initiate a reassessment of an individual's training needs based on observed job performance.
Should such an assessment indicate a need, additional training should be conducted as soon as practical.
The evaluation program may also include confidential questionnaires to obtain feedback and suggestions from the trainees for improving the training program (see Tables 2 and 3).
- 2. 7 What Records of Training Should Be Maintained Although NRC regulations do not require that records of radiation protection training at UHFFPs be kept, such records are beneficial in managing training programs and in establishing evidence of training adequacy and compliance with company policies.
Records may help eliminate unnecessary repetition of train-ing as well as ensure appropriate periodic refresher training and requalifica-tion training for new work assignments.
Also, some workers (especially tran-sient workers) may work in and be trained at several different facilities.
Appropriate records would identify site-specific training and non-site-specific training in outlines, syllabuses, and other training materials. Records systems may include coded references to information sources and other training aids in order to reduce bulk.
Such trainee-specific training records may include:
1.
The worker's name, Social Security number, pay number, and any other useful identification j
2.
Job codes 3.
Work locations 4.
Department code S.
Supervisor 4
6.
Inclusive dates for each segment of training or for each different training program.
7.
A specific description of all training completed satisfactorily by the worker, including references to pertinent lesson plans, course outlines, syllabuses, brochures, video tapes, texts, tests (including test questions and oral and on-the-job checklists).
Specific reference may be made to such materials by date, edition, issue, etc.
8.
A performance rating for each different training program completed by the worker.
This rating normally consists of a numerical or letter grade or a written evaluation.
9.
The source of training, i.e., the training facility and its location.
10.
The name and signature of each instructor and examiner involved in each segment of training.
11.
Copies of written examinations, including grades, signed and dated by the examiner.
3.
ELEMENTS OF A RADIATION PROTECTION TRAINING PROGRAM 3.1 Objectives A licensee's radiation protection training program may include the following cbjectives:
1.
Provide the information needed by each person to effectively control his/her exposure to radiation and radioactive material and the exposures others may receive as a result of his/her actions.
2.
Provide the information needed by each person as a basis for understanding (a) the biological effects of radiation (including both immediate and lat-ent effects), and (b) how different levels of radiation dose affect the human body.
3.
Provide information needed by each person for complying with license con-ditions, NRC Regulations, and plant rules and procedures and for properly responding to warnings and alarms under both normal and accident conditions.
4.
Provide the information needed by each person for understanding the func-tion of radiation detection and measurement instruments and knowing how to respond to data provided by them.
3.2 Content The RPT program should include for each class of trainees the topics listed in Table 1 that are appropriate for their specific job categories.
The inclusion of topics and the depth of treatment of each topic should be varied to meet the needs of each individual or group requiring training and should include those radiation safety subjects specific to the plant in which the worker will be employed.
Once the topics are selected for the specific class, instructors should adhere to lesson plans and outlines in order that training records will 5
I accurately reflect the training given each worker, including references and training aids.
Some useful documents relevant to UHFFP training are listed in the Reference section of this guide.
3.3 Training with Mockups Experience has established that training effectiveness is greatly enhanced when, i
in addition to classroom training, equipment or facility mockups are used to allow trainees to become familiar with tasks (especially repair and maintenance procedures) in a realistic context prior to beginning their work with radio-active materials or equipment containing radioactive materials.
This type of training is especially valuable for work involving tasks that may result in exposure of personnel to surface contamination or airborne radioactive material l
and for work involving a potential for accidental criticality.
3.4 Role of Radiation Protection Staff The radiation protection staff should be thoroughly conversant with the subject discussed in the training program and should personally participate in the training so that employees will know the role and functions of radiation safety personnel, and have confidence in management's interest in their personal safety.
Radiation safety staff members may themselves serve as training personnel or may provide technical support to the training staff in the development and conduct of the RPT.
l
\\
4 6
i
TABLE la SUBJECTS THAT MAY BE INCLUDED IN TRAINING PROGRAMS FOR EMPLOYEES i
0F URANIUM HEXAFLUORIDE AND FUEL FABRICATION PLANT 5.
Items with asterisks are not usually appropriate for the average plant worker but may be included in extended training for supervisory engineers, scientists, Cnd radiation safety technicians.
l
.I.
INTRODUCTION TO THE PLANT RADIATION PROTECTION PROGRAM l
A.
Purposes of Training I
1.
Maintenance of safe workplace.
a.
Areas of plant where radiation exposure may occur, b.
Safety is part of the job.
2.
Acquaint worker with plant radiation safety program and staff.
3.
Acqutint worker with plant rules and procedures for the safety of himself or herself and others.
l 4.
Acquahtt worker with g?vernment regulations and license conditions that the plant must foilow for his or her protection and the protec-I tion of others, includ ng provisions of 10 CFR Part 19 for articles, i
l instructions, reports And inspections.
5.
Motivate worker to follow safe practices and procedures.
8.
General Organization and Description of Plant Operations where Radiation Exposure is Possible.
C.
Oraanization of the Radiation Safety Program l
l 1.
Relationships between radiation safety and other plant safety programs.
i l
2.
Management's responsibilities for protection of workers and the public.
l a.
Provide safe environment.
b.
Provide radiation safety program.
- This table is not intended to represent a particular course outline.
It is a checklist of topics in a particular order that may aid the qualified trainer to prepare outlines for particular training courses with coverage of each topic in the depth appropriate for the audience and facility.
Additional more detailed breakdowns of some of this subject material may be found in IAEA j
i Technical Report No. 166. Reference 22.
l
\\
-3.
The worker's responsibilities and rights.
a.
Reporting to supervisor conditions leading to violations, b.
Following safety rules and procedures.
c.
The right to request inspections, exposure information, and i
discussions with inspectors where radiation exposure is possible.
4.
The radiation safety training program.
5.
Where to obtain further information.
a.
Radiation safety s_taff and management availability.
b.
10 CFR Part 19 information and posting requirements, state agency provisions.
c.
Other references - Regulatory Guides 8.13 and 8.29.
Bibliography l
in this guide.
D.
Motivations for Learning About Radiation Protection 1.
Lower personal risks.
2.
Lower risks to others.
3.
Lower liabilities and losses to self and company.
4.
Help employer meet regulatory and license requirements (10 CFR Part 19, 10 CFR Part 20, Licenses posted).
5.
Employee's responsibility to report promptly any conditions that may lead to violations of license conditions or regulations, or cause l
unnecessary exposures.
t l
E.
k ed for Worker Feedback in Training Sessions i
1.<
Importance of examinations.
l l
2.
Mistakes as a requisite for learning.
1 i
3.
Importance of questions.
4.
Importance of training exercises and drills.
l
- Items with asterisks are not usually appropriate for the average plant worker.
l but may be included in extended training for supervisory engineers, scientists, and radiation safety technicians.
l 8
I
5.
On-the-job versus formal training.
6.
Verbal interactions to bring out and integrate worker's (past) experiences.
7.
Evaluations of training by the worker (See Tables 2 and 3).
II.
CONCEPTS OF RADIATION, RADI0 ACTIVITY, RADIATION EXPOSURE, AND DOSE
- A.
Concepts of Ionizing vs. Nonionizing Radiation 1.
Definition of " radiation."
2.
Familiar examples of nonionizing radiation.
3.
Familiar examples of ionizing radiation.
B.
Radionuclides vs. Stable Elements and Isotopes C.
Types of Ionizing Radiation 1.
Alpha particles.
a.
Nature - mass, charge, constituents, b.
Velocity and energy
- c.
Shortness of range, high (specific) ionization in short range.
d.
Energies of alphas from uranium isotopes and other fissionable nuclides.*
2.
Beta particles, a.
Nature - mass, charge, constituents.
b.
Negatrons and positrons.*
c.
Velocities and energy spectra.*
d.
Ranges and rates of attenuation in different materials, heavy materials.*
f.
Self-absorption of uranium feed and fuel materials.*
g.
Beta surface exposure potentials in plant operations, e.g.,
50-100 mrem / hour near the surface of pellet trays and boats and 5-10 mrem / hour near surfaces of fuel rods and bundles.
3.
Gamnia rays and X-rays, a.
Nature - electromagnetic, but energy packaged as photons.
Origins of gamma and x-radiation (including bremsstrahlung) in plant operations.
9
r I
f l
b.
Velocity and discrete energies.
c.
Absorption and scattering - types of interactions with electrons l
and atoms.*
d.
Ranges and rates of attenuation different materials.
(
e.
Relative exposure potential in various plant locations - 1 to 2 mrem / hour at 1 foot from surface of UO pellet trays or boats, 2
l fuel rods and bundles, higher or multiply-used UFs cylinders or where operations involving melting or reduction to uranium metal are conducted and the thorium and protactinium daughters cf uranium become separated as " bottoms," scale, or residue.
4.
Neutrons l
a.
Nature and origin b.
Description of the fission process, neutron chain reactions, and plant areas where criticality is possible.
i l
c.
Description of other neutron sources that may be used in the
- facility, d.
Criticality concepts and their importance - mass and geometry control principles, density dependence, moderation, enrichment dependence.
D.
Radiation Exposure and Dose Concepts 1.
Exposure - energy absorption density in air.
2.
Measurement of exposure - ionization chambers, secondary detectors-film, TLD, chemicals.
3.
Units of Exposure - roentgen, joules, subunits, for x or gamma; kerma; fluence (versus energy) for neutrons.
4.
Absorbed dose (D) - energy absorption density in tissue or other materials.
5.
Units of absorbed dose rad, gray, subunits.
6.
Differences in whole body and partial body exposure and dose.
7.
Concept of dose equivalent (DE) - for intercomparing and adding biological effects of different kinds and energies of radiation.
- Items with asterisks are not usually appropriate for the average plant worker, but may be included in extended training for supervisory engineers, scientists, and radiation safety technicians.
10
8.
Units of dose equivalent:
a.
Quality factors (QF) b.
rem, sievert, subunits c.
Practical calculation of DE for radiation protection purposes:
DE = D x QF 9.
Use of new ICRP26 weighted DE for summing partial body exposures.*
10.
Decrease with distance of D and DE from point sources (inverse square law).
11.
Decrease with distance of D and DE from area and volume sources.*
12.
Orientation to relative magnitudes of background radiation exposures, exposures in uranium fuel fabrication operations, and individual and population doses in various segments of the nuclear fuel cycle.
III. BIOLOGICAL EFFECTS OF RADIATION AND COMPARISONS OF RISK A.
General Nature of Biological Damage from Radiation 1.
Damage to cell nucleus and cytoplasm.*
2.
Production of ionization and chemical radicals near critical bio-chemical sites.
3.
Multiple-hit, multiple-target concepts of production of lethal damage to cells and carcinogenic and genetic transformations.*
1 4.
Repair of biochemical lesions.*
5.
Dependence of repair and biological effects on dose rate, linear energy transfer (LET), and fractionation of dose.*
6.
QF of neutrons vs QF for gamma, beta, and internal alpha dose.
B.
High Dose Effects (More than 25 rem) 1.
Blood changes begin about 50-100 rem.
2.
Acute radiation syndrome above about 100 rem in 1 day, Nausea, vomiting, fatigue, leukopenia (lower resistance to a.
infection), hair loss.
b.
Lethality above about 200 rem - hemopoietic vs. GI vs. CNS death, c.
Loss of fertility.
d.
Possible long-term increase in cancer.
l l
11
3.
Effects of spreading out dose a.
No acute syndrome expected at 5 rem / year for 20 years, b.
Increase chances of cancer by up to a few percent.
c.
Recent National Academy of Sciences BEIR III estimates, UNSCEAR 1982 estimates.*
4.
Cataracts, above 200 rem.
5.
Effects on pregnant women.
a.
Effects on mother as above.
b.
Teratogenic effects on child (serious above 25 rem, keep dose to fetus less than 0.5 rem during gestation).
c.
Higher cancer (including leukemia) incidence in children irradiated in utero.
d.
Summary of instructions in Regulatory Guide 8.13, NCRP Report 40.
6.
Sterility a.
Possible azospermia and temporary sterility above about 50 rem.
b.
Permanent sterility possible only at exposures in lethal range.
7.
Skin or surface tissue " burns" for partial body or extremity exposures.
a.
Erythema above about 200 rad.
b.
Ulceration, permanent scarring above about 800 rad.
c.
Necrosis, amputation, late cancer possible above about 1500 rad.
C.
Low Dose Effects (less than 25 rem) 1.
Slight blood changes.
2.
Chromosomal anomalies above about 5 rems.
3.
Genetic effects - first generation and equilibrium.
4.
Cancer - relative risks and latent periods.
5.
Chances of cancer and genetic affects vs. dose - kinds of dose-response relationships.
6.
Nonthreshold concept for gene mutations.
7.
Comparisons of radiation risks, risks from other industrial employment, and common risks of everyday life.
12
8.
Possible synergism between low dose radiation and chemical exposures.
9.
Balancing individual and collective dose risks.
IV.
RADIATION EXPOSURE AND DOSE LIMITS A.
Whole Body Exposure and Dose Limits 1.
Current 10 CFR Part 20 limits.
a.
Application of dose limits to whole body, head and trunk, active blood forming organs, lens of eyes, and gonads, to the specific plant operating conditions.
b.
Practical application of weekly or monthly dose limits according to plant radiation safety programs.
c.
Actions when exceeded and employee's responsibilities in meeting regulatory and plant requirements.
d.
Practical conversions of R to rad and rem.
e.
New SI units.*
2.
ICRP 26 dose limiting system.*
B.
Partial Body Exposure and Dose Limits 1.
Current 10 CFR Part 20 limits.
a.
Hands and forearms, feet and ankles.
b.
Skin.
c.
Management of dose limits according to plant procedures.
2.
Conversion and summing of partial body doses to obtain weighted dose-equivalent of whole body exposure according to ICRP 26.*
C.
Requirements and Company Policies for Keepina Doses "As Low As Reasonably Achievable (ALARA)".
1.
Citations in 10 CFR Part 20, regulatory guides, ICRP and NCRP.
2.
Biological reasons for maintaining doses ALARA.
D.
lJmitsonConcentrationsandIntakesofRadioactiveMaterial 1.
Current 10 CFR Part 20 limits on air and water concentrations of uranium and daughter radionuclides.
1 2.
Importance of plant equipment for limiting and monitoring air concentrations.
13
3.
More recent information on chemical toxicity of uranium.
4.
Forms and compounds in plant for which chemical toxicity may be significant relative to radiological toxicity, if any.
5.
Target organs receiving greatest doses for uranium compounds that may become airborne.
6.
Need to maintain intakes and internal doses ALARA.*
E.
Plant Contamination Limits 1.
Suspension and resuspension of contamination as possible sources of airborne radioactivity - nonvolatile dusts, mists, metal, fumes.
2.
Possibilities for ingestion of unsealed radioactive material.
3.
Use of practical contamination limits to control exposure ALARA to intake of radioactive material (reference Regulatory Guides 8.24 and 8.21).
V.
PRINCIPLES AND WORK PRACTICES FOR THE EMPLOYEE'S CONTROL OF OWN RADIATION EXPOSURE A.
Principles of Self-Protection from External Radiation 1.
Field Use of Radiation Survey Instruments by the worker.
a.
Types of survey instruments and their functions.
b.
Selection and proper use of survey instruments by the worker.
2.
Limiting time of exposure a.
Interpreting exposure or dose rates per hour in terms of minutes and seconds of exposure.
b.
Exposure is proportional to time in the radiation field.
c.
Plan operations and practice with nonradioactive materials to reduce handling times where appropriate.
d.
Maximum beta dose rates near uranium compounds are 200 to 250 millirad per hour, e.
Maximum gamma exposure rates near purified uranium compounds are 2 to 3 mR/ hour except during criticality, f.
Exposure rates in areas where uranium daughter products may be concentrated.
l l
14
3.
Maximizing distance Inverse square reduction of dose rate with distance for small a.
gamma ray sources.
b.
Rapid attenuation of beta exposures with distance in air - keep skin of whole body at arm's length where possible.
Use tongs and handling equipment rather than hands for manipu-c.
lating radioactive materials except where written procedures indicate limited handling of certain materials to save time.
4.
Criticality safety a.
Examples of criticality incidents b.
Methods of prevention - geometry (approved containers storage),
mass limits (safe batches), density, moderation, maximum enrich-ment, procedural controls, material identification.
c.
Protective actions when criticality alarm sounds, d.
Collection of wastes in safe batch containers.
Maintenance of integrity of waste storage facility.
e.
f.
Preventing loss or misidentification when transporting materials between areas or laboratories, Inventory control and accountability of special nuclear materials.
g.
5.
Use of shielding Attenuation of gamma rays by shielding provided in plant a.
equipment.
b.
Need to shield beta rays with light (low Z) materials to avoid additional x-radiation, Protective clothing as partial shielding against beta radiation.
c.
d.
Self-shielding of material in bulk form (self-absorption).
6.
Proper use of personnel monitoring equipment.
B.
Principles of Self-Protection from Internal Radiation Exposure (due to breathing or eating (ingesting) radioactive material).
1.
Processes that generate airborne radioactivity or contamination, Uranium hexafluoride evaporation - importance of early leak a.
detection, actions.
15
b.
Uranium hexafluoride - ammonium diuranate conversion.
c.
Milling - ball, hammer, jet o.
Blending e.
Powder pressing operations f.
Sintering g.
Grinding of sintered products h.
Glove boxes used in ball milling, screening, blending, pellet pressing operations.
i.
Hoods and exhaust ducts for equipment used in fabricating uranium pellets.
j.
Hoods vented through filters for grinding, cutting, powder mixing, pressing, powder sampling, h.
Radioactive chips and dusts from lathes, welding fixtures, and drill presses.
1.
Changing of filters and prefilters in hood exhausts and l
ventilation exhaust plenums.
j.
Sources of contamination in chemical and process technology laboratories.
k.
Scrap recovery processes.
I 1.
Incinerator m.
Decontamination and waste disposal operations.
2.
Rules for protecting against ingestion and inhalation of radioactive material:
a.
Wearing work gloves according to plant procedures.
i b.
Proper use of protective clothing.
c.
Proper use of change room facilities and separation of clean areas, step-off line.
d.
Procedures and order of donning and removal of shoe covers, coveralls, gloves, head covers, and respiratory protective equipment.
Exit surveys - alarms and actions for contamination.
Rules against smoking, drinking, eating, gum and tobacco chewing, e.
and application of cosmetics in potentially contaminated areas.
l 16 l
f.
Use of radiation survey instruments for checking contamination:
(1) Alpha contamination survey meters.
(2) Beta contamination surveys.
(3) Gamma emitter contamination surveying.
(4) Interpretation of contamination surveys, action levels, and actions (See Regulatory Guide 8.24).
Need for daily survey meter checks and 6-month calibrations, (5) g.
Choice of respiratory protective equipment - dust, mists, metal fumes, chemical cartridges, removal mechanisms (Reference 13, NUREG-0041).
h.
Rules and procedures for fitting, wearing and storing respiratory protective equipment.
I 1.
Responies to air monitor readings and alarms.
j.
Visual detection of certain forms of uranium contamination, k.
Need to maintain integrity of smooth work and floor surfaces.
1.
Proper removal of protective clothing, monitoring, showering and decontamination at end of workshift and before lunch periods of other periods when leaving controlled areas.
3.
Rules for use of hoods, glove boxes, and other enclosures for contain-ment of radioactive dusts and fumes:
a.
Maintenance of integrity of laminar flow in hoods, b.
Maintenance of gloves in gloveboxes c.
Glove changing methods d.
Checking air flow or negative pressure indicators Entry to and removal of materials from containment systems.
e.
4.
Radiation caution signs and controls for access to restricted areas.
Radiation areas, airborne radioactivity areas, radiation work permit signs, uranium storage signs, shipping labels, door symbols, door seals.
5 Action levels for reporting personal, equipment, or area contamination to supervisor or the Radiation Safety Office.
6.
Procedures for surveying and opening packages.
7.
General good housekeeping - prevent contamination buildup.
17
C.
Other Plant Operating Procedures Related to Maintaining Exposures ALARA During the Storage, Transfer or Use of Radioactive Materials 1.
Proper storage of radioactive materials not in use.
2.
Use of fire extinguishers in fires involving special nuclear material.
VI.
RADIATION PROTECTION PROGRAM PROVIDED BY MANAGEMENT A.
General surveillance of plant safety - locations of radiation protection offices.
B.
Surveys of radiation and radioactive contamination 1.
External beta gamma exposure level monitoring.
2.
Monitoring surfaces with alpha detectors.
3.
Smear surveys of plant areas.
4.
Leak testing of sealed sources.
C.
Personnel Monitoring for External Exposure 1.
Providing and collecting personnel monitoring badges (film, TLD, etc.).
2.
Providing and collecting pocket dosimeters.
3.
Calibration or quality control checks on dosimeter evaluations.
4.
Dostmeter evaluation or arrangements for vendor evaluation.
5.
Review of personnel exposure data and reports.
6.
Maintenance of exposure record and retrieval systems.
7.
Preparation of reports to workers, plant management, and the government as required by government regulations and plant policies.
8.
Special exposure investigations and notifications to regulatory agencies, as appropriate.
D.
, Internal Exposure Monitoring (" Bioassay")
1.
Need for excretion analyses and in vivo counting to evaluate possible intakes of radioactive material.
2.
Precautions necessary in sample collection to obtain representative, uncontaminated samples.
Showering necessary for in vivo or "whole body" counting.
3.
Calculat.fon of internal doses from bioassay analyses by radiation safety staff using inathematical models of ICRP and others.*
18
4.
Actions levels for different forms of uranium and actions that may be taken (See Regulatory Guide 8.11).
5.
Record maintenance and reports.
6.
Availability to worker of information in the internal dose record.
7.
Scheduling workers for bioassay or in vivo ("whole body" or " lung counting") measurements.
E.
Special Exposure and Job-Time Studies as Requested by Managers F.
Air Monitoring to Protect Against Radioactive Material Intake 1.
General air monitoring.
2.
Breathing zone stationary air samplers for work station monitoring.
3.
Ventilation checks - need to ensure integrity and proper air flow for all hoods, fans, and air intake and exhaust systems.
4.
Personal or lapel air samplers.
G.
Radiation Safety Instrument Calibration and Maintenance 1.
Calibration.
2.
Battery replacement and adjustment.
3.
Pocket chamber and Personnel Monitoring Badge Calibrations or Quality Control Checks.
4.
Survey instrument repair.
5.
Instrument selection and distribution.
6.
Check source calibrations and inventory.
H.
Protection of Environment Outside Plant 1.
Environmental sampling program.
2.
Air filtration system checks and maintenance.
3.
Importance of maintaining litegrity of ventilation filtration systems.
4.
Waste disposal program.
I.
Responsibilities of, and Services Available from, the Radiation Safety Office (Administration. Consultation, Worker and Public Information) 1.
Review or approval from radiation safety standpoint of facilities, equipment, and procedures used in areas where radioactive materials are handled.
19
2.
Assisting management in preparation of license applications and amendments.*
l 3.
Preparation of safety evaluation reports for licensing.*
4.
Programming of routine required surveys.*
5.
Supervision of routine radiation safety operations.
6.
Training and retraining all personnel in radiation safety and criticality principles and rules at levels of depth and breadth related to jobs and tasks.
7.
Training in the wearing of respirators.
8.
Consultation with management on radiation safety matters.*
9.
Counseling workers as requested on radiation safety matters - answering questions dealing with incidents of personal contamination or intake.
10.
Conduct radiation safety audits with management.*
11.
Conduct radiation safety inspections with government inspectors.*
12.
Selecting, ordering, and maintaining radiation safety instruments, equipment, and supplies.
I 13.
Radiation record maintenance and related computer programming.
l 14.
Planning responses to incidents and energencies involving radioactive materials.
15.
Providing instructions to outside agencies (e.g., fire department) that would respond to an emergency situation involving or potentially involving radiation.*
16.
Meeting to keep up with radiation safety technology and regulatory changes.*
17.
Preparation of radiation safety reports to management.*
VII. EMERGENCY PLAN AND DRILLS A.
Plant safety and accident control procedures.
B.
Methods of dealing with process malfunctions, checking fixed station samplers for contamination immediately upon suspicion of a release of uranium.
~
C.
Emergency signals and alarms.
l
D.
Evacuation routes, evacuation route. signs, and evacuation procedures.
E.
-Assembly areas and individual reporting locations (staging areas).
F.
Emergency communications and command center.
G.
Location of any'necessary emergency equipment.
H.
First aid instructions.
I.
Conduct during emergency drills.
21
TABLE 2 STUDENT EVALUATION OF COURSE Name:
Instructor:
The following statements are to be rated on a scale of I to 5.
A rating of 5 indicates complete agreement with the item while a I indicates that you do not agree at all.
Ratings of 3 mean general agreement.
Id d
)
J H<
c.
m 2
Z H
o m
o u
o Z
l.
The objectives of the course were fully explained at the beginning of the course.
5 4 3 2 1 2.
Training objectives of the course are realistic and obtainable.
5 4 3 2 1 3.
Training objectives are proper for the stated content of the course.
5 4 3 2 1 4.
Course materials were organized in a clear and understandable manner.
5 4 3 2 1 5.
Tests were representative of the course content.
5 4 3 2 1 6.
The grading of tests and performance standards were explained at the beginning of the course.
5 4 3 2 1-7.
The instructors use of instructional aids.
and training devices were adequate for this course.
5 4 3 2 1 8.
I am satisfied with the course.
5 4 3 2 1 9.
This course will help me perform my job.
5 4 3 2 1
- 10. I am aware of how this course fits with all of my previous and planned future training.
5 4 3 2 1 Student Evaluation of Course (From P. M. Haas et al., Reference 4, 1983.
This type of form may be helpful in providing feedback for training improsements and in giving the employee motivation in cooperating with the training staff.)
22
TABLE 3 STUDENT EVALUATION OF INSTRUCI'OR Name:
Instructor:
The following statements are to be rated on a scale of I to 5. A rating of 5 indicates com-plete agreement with the item while a I indicates that you do not agree at all. Ratings of 3 mean general agreement.
a w
)
H 3
W H
J ac a.
m 2
z H
O W
O U
C Z
l.
The instructor's presentations are clear.
5 4 3 2 1 2.
The instructor is prepared for class.
5 4 3 2 1 3.
I can communicate with the instructor.
5 4 3 2 1 4.
Questions that come up in class are always answered.
5 4 3 2 1 5.
The instructor has a good grasp of the course content.
5 4 3 2 1 6.
The instructor stimulates discussion.
5 4 3 2 1 7.
The instructor shows enthusiasm for his job during class sessions.
5 4 3 2 1 8.
All levels of student understanding are addressed by the instructor.
5 4 3 2 1 9.
At the end of each class the instructor summarizes what has been taught.
5 4 3 2 1
- 10. The instructor uses class time efficiently.
5 4 3 2 i Student Evaluation of Instructor 1
(From P.M. Haas.et al., NUREG/CR-3414, 1983, Reference 4.)
23
i l
REFERENCES 1.
Title 10, Chapter 1, Part 19, Code of Federal Regulations " Notices, Instructions, and Reports to Workers; Inspections," U.S. Nuclear Regula-tory Commission, Washington, DC.
2.
Title 10, Chapter 1, Part 20, Code of Federal Regulations, " Standards for Protection Against Radiation," U.S Nuclear Regulatory Commission, Washington, DC.
3.
National Council on Radiation Protection and Measurements, NCRP Report No. 71, " Operational Radiation Safety Training, "NCRP Publications, 7910 Woodmont Ave., Suite 1016, Bethesda, MD 20814, 1983.
4.
P.M. Haas, D.L. Selby, M.J. Hanley, and R.T. Mercer, " Evaluation of Train-ing Programs.and Entry Level Qualifications for Nuclear Power Plant Control Room Personnel Based on the Systems Approach to Training," NUREG/CR-3414, September 1983.
5.
U.S. Nuclear Regulatory Commission, Regulatory Guide 8.27, " Radiation Pro-tection Training for Personnel at Light-Water-Cooled Nuclear Power Plants,"
March 1981.
6.
U.S. Nuclear Regulatory Commission, Regulatory Guide 8.24, " Health Physics Surveys During Enriched Uranium-235 Processing and Fuel Fabrication,"
October 1979.
7.
U.S. Nuclear Regulatory Commission, Regulatory Guide 8.21, " Health Physics Surveys for Byproduct Material at NRC-Licensed Processing and Manufacturing Plants," October 1979.
8.
U.S. Nuclear Regulatory Commission, " Radiological Containment Handbook,"
NUREG-0914, October 1982.
9.
Stephen A. McGuire and Carol A. Peabody, " Working Safely in Gamma Radio-graphy," NUREG/BR-0024, U.S. Nuclear Regulatory Commission, Washington, DC 20555, 1982.
10.
U.S. Nuclear Regulatory Commission, DRAFT Regulatory Guide, Task CE-227-4,
" Standard Format and Content for the Health and Safety Sections of License Renewal Applications for Uranium Hexafluoride Production Plant," September 1983.
11.
U.S. Nuclear Regulatory Commission, Regulatory Guide 8.13, " Instruction Concerning Prenatal Radiation Exposure," November 1975.
12.
Radiation Education Notebook, Educational Services Office, Atomic Indus-trial Forum, Inc. 7101 Wisconsin Avenue, Bethesda, MD 10814.
13.
U.S. Nuclear Regulatory Commission, Regulatory Guide 8.11. " Applications of Bioassay for Uranium," June 1974.
24 j
6 14.
U.S. Nuclear Regulatory Commission, Regulatory Guide 8.29, " Instruction Concerning Risk from Occupational Radiation Exposure," July 1981 15.
U.S. Nuclear Regulatory Commission, NUREG-0041, " Manual of Respiratory Protection Against Airborne Radioactive Materials," October 1976 16.
National Academy of Sciences, National Research Council, "The Effects on Populations of Exposure to Low Levels of Ionizing Radiation,"
Washington, DC 20418, July 1980 17.
International Commission on Radiological Protection, ICfr#26, "Recom-mendations of the International Commission on Radiological Protection,"
Pergamon Press, Maxwell House, Fairview Park, Elmsford, NY 10523, January 1977.
18.
National Safety Council, " Accident Facts," published annually, 44 N.
Michigan Avenue, Chicago, IL 60611.
19.
International Commission on Radiological Protection, ICRP-27, " Problems Involved in Developing an Index of Harm," Pergamon Press,. Maxwell House, Fairview Park, Elmsford, NY 10523, May 1977.
- 20.. United Nations Scientific Committee on the Effects of Atomic Radiation, United Nations Publication Sales NO. E.77.IX.1, " Sources and Effects of Ionizing Radiation," New York, NY 1001, 1977; also 1982.
21.
U.S. Department of Health, Education and Welfare (currently the Depart-ment of Health and Human Services), " Report of the Interagency Task Force on the Health Effects of Ionizing Radiation," Washington, DC 20201, June 1979.
22.
International Atomic Energy Agency, " Training in Radiological Protection for Nuclear Programmes," Technical Report Series No. 166, International Atomic Energy Agency, Venna, Austria, 1975.
23.
10 CFR Part 70, Section 70.24, " Criticality Accident Requirements."
24.
Regulatory Guide 8.5, " Criticality and Other Interior Evacuation Signals.
25.
Regulatory Guide 3.42, " Emergency Planning for Fuel Cycle Facilities and Plants Licensed Under 10 CFR Parts 50 and 70," September 1979.
26.
J. B. Revelle, Safety Training Methods, John Wiley and Sons, Inc.,
Somerset, NJ, 1980, 248 pp.
25
NRC PORet 335 U S. NUCLEM4 E.E IULI.YORv COesasisssON t kEPOAT NuveEd #4ss,pasaavrs0C, saa vo ete, er ears r
(2 846 E*," S$'-
BIBLIOGRAPHIC DATA SHEET NURE-nZ7 SEE sNsTRUCteONS ON THE REVERSE 2 TITLE AND SUEYiTLE 3 LE AVE SLANE Radiation Protection Training at Uranium Hexafluoride end Fuel Fabrication Plants 4 DATE REPg COvPLETED l
VEAR
=O41-
- a'""
Anril 19M
' / DATE REPORT ISSUED A. Brodsky, A. L. Soong and J. Bell f"
l py 1985 iPo. 0awi=oOasA~ AiiON NA E ANo uAiu o AooREss r<ne. eio c,
. PRO; Asn Oa Nir huweEa Division of istion Programs and Earth Sciences yin Oa c.aANr huusEa Office of Nuc1 Regulatory Research f
U. S. Nuclear R ulatbry Commission Washington. DC 20 5 to $PQN50 RING ORGANilATION NAw NO M A LING ADDRE5S (fachede se Comes tie TYPE OF REPONT Same as 7 above.
Technical Report a PERIOD COvtHED ffacts,ve en.so 12 SUPPLEMENT ARY NOTES g
.2 A.ir R AC T,m This report provides general in tiog and references useful for establishing or optrating radiation safety tr pyramsinplantsthatmanufacturenuclearfuels or process uranium compounds that used in the manufacture of nuclear fuels. In addition to a brief summary of the ciples of effective management of radiation safety training, the report also conta s an appendix that provides a comprehensive ch:cklist of scientific, safety, snd m ement topics, from which appropriate topics may be selected in preparing training out es for various job categories or tasks pertaining to the uranium nuclear fuels stry. The report is designed for use by radiation safety training prof 6ssionals who ave the experience to utilize the report to not only select the appropriate topics, b also to tailor the specific details and depth of coverage of each trainiryr, session to tch both employee and management needs of a particular industria [bperation.
/
Ig Ay Ag(Agsp ry 14 DOCUMENT ANALVlis - e REYWORQ$'OESCR+PTOR$
g f
}
$TATEVENT
/
s radiation protecti'on training, Unlimited 16 SECURiT Y CL AS$iFICAfiON i Th. pereo Unclassified
. iOe.T.,IE miz0 PEN E NoEO,ERW, i r.,,,
Unclassified 17 NyWSt R O* PAGES
,.,R.C E
UNITED STATES
'ounrwctass man C'UCLEAR C.E ULATORY CHMMISSION
- '^'d"."^'
WASHINGTON, D.C. 20665 u
- wash oc OFFICIAL BUSINESS
~ PENALTY FOR PRIVATE USE. 4300
' 1'? O '~,% 0 7 8 e 7 7 1 ~1At1C31RU1'51 US PC AD"-DIV Ur IIDC P O! F C-1 5 i -T i r NUHEG PLLICY s
W-501
.JAsMINGT0t; L[
Or. 55 O
Q d
mO Cm f"
mD
- rm
. llD 6e
>do.
2 m
Z*
-4 (n
a
-Q
.e Q
Q
~
l-x
/